ND-18-0640, Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.6.02.02c (Index Number 595)

From kanterella
(Redirected from ML18127A006)
Jump to navigation Jump to search
Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.6.02.02c (Index Number 595)
ML18127A006
Person / Time
Site: Vogtle  
Issue date: 05/04/2018
From: Yox M
Southern Nuclear Operating Co
To:
Document Control Desk, Office of New Reactors
References
ND-18-0640
Download: ML18127A006 (7)


Text

jtk. Southern Nuclear MAY 0 4 2018 Michael J. Yox Regulatory AffairsDirector Vogtle 3 &4 7825 River Road Waynesboro, GA 30830 706-848-6459 tel 410-474-8587 cell myox@southernco.com Docket Nos.:

52-025 52-026 ND-18-0640 10CFR 52.99(c)(3)

U.S. Nuclear Regulatory Corrimjsslon Document Control Desk Washington, DC 20555-0001 Southern Nuclear Operating Company Vogtle Electric Generating Plant Unit 3 and Unit 4 Notice of Uncompleted ITAAC 225-davs Prior to Initial Fuel Load Item 2.6.02.02c [Index Number 5951 Ladies and Gentlemen:

Pursuant to 10 CFR 52.99(c)(3), Southern NuclearOperating Company hereby notifiesthe NRC that as of May 1, 2018, Vogtle Electric Generating Plant(VEGP) Unit 3 and Unit 4 Uncompleted Inspections, Tests, Analyses, and Acceptance Criteria (ITAAC) Item 2.6.02.02c [Index Number 595]

has not been completed greater than 225-days prior to initial fuel load. The Enclosure describes the planforcompleting this ITAAC. Southern Nuclear Operating Companywill, at a later date, provide additional notifications for ITAAC that have not been completed 225-days prior to initial fuel load.

This notification is informed by the guidance described in NEI 08-01, Industry Guideline for the ITAAC Closure Process Under 10 CFR Part 52, which was endorsed by the NRC in Regulatory Guide 1.215. In accordance with NEI 08-01, this notification includes ITAACfor which required inspections, tests, or analyses have not been performed or have been onlypartially completed. All ITAAC will be fully completed and allSection 52.99(c)(1) ITAAC Closure Notifications will be submitted to NRCto support the Commission finding that all acceptance criteria are met priorto plant operation, as required by 10 CFR 52.103(g).

This letter contains no new NRC regulatory commitments.

If there are any questions, please contact Tom Petrak at 706-848-1575.

Respectfully submitted.

Michael J. Yox Regulatory Affairs Director Vogtle 3 &4

Enclosure:

Vogtle Electric Generating Plant (VEGP) Unit 3 and Unit 4 Completion Plan for Uncompleted ITAAC 2.6.02.02c [Index Number 595]

MJY/PGL/amw

U.S. Nuclear Regulatory Commission ND-18-0640 Page 2 of 3 To:

Southern Nuclear Operating Company/ Georgia Power Company Mr. D. A. Bost (w/o enclosures)

Mr. M. D. Rauckhorst (w/o enclosures)

Mr. M. D. Meier Mr. D. H. Jones (w/o enclosures)

Mr. D. L. McKinney Mr. M. J. Yox Mr. D. L. Fulton Mr. J. B. Klecha Mr. G. Chick Mr. F. H. Willis Ms. A. L. Pugh Mr. A. 8. Parton Mr. W. A. Sparkman Mr. C. E. Morrow Ms. K. M. Stacy Mr. M. K. Washington Mr. J. P. Redd Ms. A. C. Chamberlain Mr. D. R. Culver Mr. T. G. Petrak Document Services RTYPE: VND.LI.L06 File AR.01.02.06 cc:

Nuclear Reaulatorv Commission Mr. W. Jones (w/o enclosures)

Ms. J. M. Heisserer Mr. C. P. Patel Mr. M. E. Ernstes Mr. G. J. Khouri Mr. T. E. Chandler Ms. S. E. Temple Ms. P. Braxton Mr. N. D. Karlovich Mr. A. J. Lerch Mr. C. J. Even Mr. F. D. Brown Mr. B. J. Kemker Ms. A. E. Rivera-Varona Ms. L. A. Kent Mr. P. B. Donnelly Ms. N. C. Coovert Qqiethorpe Power Corporation Mr. R. B. Brinkman

U.S. Nuclear Regulatory Commission ND-18-0640 Page 3 of 3 Municipal Electric Authority of Georgia Mr. J. E. Fuller Mr. 8. M. Jackson Dalton Utilities Mr. T. Bundros Westinahouse Electric Company. LLC Dr. L. Oriani (w/o enclosures)

Mr. D. C. Durham (w/o enclosures)

Mr. M. M. Corletti Ms. L. G. Iller Mr. D. Hawkins Ms. J. Monahan Mr. J. L. Coward Ms. N. E. Deangelis Other Mr. J. E. Hesler, Bechtel Power Corporation Ms. L. Matis, Tetra Tech NUS, Inc.

Dr. W. R. Jacobs, Jr., Ph.D., CDS Associates, inc.

Mr. 8. Roetger, Georgia Public Service Commission Ms. 8. W. Kernizan, Georgia Public Service Commission Mr. K. C. Greene, Troutman Sanders Mr. 8. Blanton, Baich Bingham

U.S. Nuclear Regulatory Commission ND-18-0640 Enclosure Page 1 of 4 Southern Nuclear Operating Company ND-18-0640 Enclosure Vogtle Electric Generating Plant (VEGP) Unit3 and Unit 4 Completion Plan for Uncompleted ITAAC 2.6.02.02c[Index Number 595]

U.S. Nuclear Regulatory Commission ND-18-0640 Enclosure Page 2 of 4 ITAAC Statement Design Commitment 2.c) Each EDSloadgroup 1, 2,3, and 4 inverter suppliesthe corresponding ac load.

Insoections/Tests/Analvses Testingofeach as-built inverter will be performed byapplying a simulatedor real load, or a combination of simulated or real loads, equivalent to a resistive load greater than 55 kW.

Acceotance Criteria Each inverter provides a line-to-line outputvoltage of208 +/- 2% Vat a frequencyof60 +/- 0.5%

Hz.

ITAAC Completion Description Testing is performed inaccordance with Unit 3 and Unit 4 component test package workorders (References 1 and 2) to demonstrate that each Non-Class 1E direct current (dc) and Uninterruptible Power SupplySystem (EDS) load group 1, 2,3, and 4 inverteridentified inthe Combined License (COL) AppendixC, Table 2.6.2-2 (Attachment A) supplies its corresponding alternating current (ac) load.

A load test is performed on each EDS inverter by applying a simulated load greater than the inverter design capacity of 55 kilowatts (kW). Inverteroutput voltage, frequency, and power are continuously monitored duringthe test and after stabilization of load, recorded on data sheets included inthe component test package workorders (References 1 and 2). Output voltage is verifiedto meet the specified acceptance criteria of 208 +/- 2% Volts (V) at a frequency of 60 +/-

0.5% Hertz (Hz) withthe specified load applied. The recorded voltage and frequency values are identified in Attachment A for each EDS inverter.

The Unit3 and Unit4 component test results confirm that each inverter provides a line-to-line output voltage of 208 +/- 2% V at a frequency of 60 +/- 0.5% Hz.

The Unit3 and Unit4 component test package workorders (References 1 and 2, respectively) are available for NRC inspection as part of the Unit 3 and Unit4 ITAAC 2.6.02.02c Completion Packages (References 3 and 4, respectively).

List of ITAAC Findings Inaccordance with plant procedures for ITAAC completion. Southern Nuclear Operating Company (SNC) performed a reviewof allfindings pertainingto the subject ITAAC and associated corrective actions. This review found there are no relevant ITAACfindings associated with this ITAAC.

U.S. Nuclear Regulatory Commission ND-18-0640 Enclosure Page 3 of 4 References (available for NRG inspection)

1. SNC921194, Rev. 0, "EDS Inverter Frequency and Voltage Test - ITAAC: SV3-2.6.02.02c"
2. SNCXXXXXX, Rev x, "EDS Inverter Frequency and Voltage Test - ITAAC: SV4-2.6.02.02c" 3.

2.6.02.02c-U3-CP-Rev 0, ITAAC Completion Package 4.

2.6.02.02c-U4-CP-Rev 0, ITAAC Completion Package 5.

NEI 08-01, "Industry Guideline for the ITAAC Closure Process Under 10 CFR Part 52"

U.S. Nuclear Regulatory Commission ND-18-0640 Enclosure Page 4 of 4 Attachment A System: Non-Class 1E do and Uninterruptible Power Supply System Unit

^Component Name

  • Tag No.

Load Bank Voltage and Frequency 3

Load Group 1 Inverter EDS1-DU-1 XXXV YYYHz 3

Load Group 2 Inverter EDS2-DU-1 XXXV YYYHz 3

Load Group 3 Inverter EDS3-DU-1 XXXV YYYHz 3

Load Group 4 Inverter EDS4-DU-1 XXXV YYYHz 4

Load Group 1 Inverter EDS1-DU-1 XXXV YYYHz 4

Load Group 2 Inverter EDS2-DU-1 XXXV YYYHz 4

Load Group 3 Inverter EDS3-DU-1 XXXV YYYHz 4

Load Group 4 Inverter EDS4-DU-1 XXXV YYYHz Notes:

  • Excerpt from COL Appendix C, Table 2.6.2-2