ND-19-0257, Unit 4 - ITAAC Closure Notification on Completion of ITAAC 2.3.02.08a.ii (Index Number 302)

From kanterella
(Redirected from ML19079A248)
Jump to navigation Jump to search

Unit 4 - ITAAC Closure Notification on Completion of ITAAC 2.3.02.08a.ii (Index Number 302)
ML19079A248
Person / Time
Site: Vogtle  
Issue date: 03/19/2019
From: Yox M
Southern Nuclear Operating Co
To:
Document Control Desk, Office of New Reactors
References
ND-19-0257
Download: ML19079A248 (6)


Text

^

Southern Nuclear MAR 1 9 2019 Michael J. Yox Regulatory Affairs Director Vogtle 3 & 4 7825 River Road Waynesboro, GA 30830 706-848-6459 tel Docket No.: 52-025 52-026 ND-19-0257 10CFR 52.99(c)(1)

U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001 Southern Nuclear Operating Company Vogtle Electric Generating Plant Unit 3 and Unit 4 ITAAC Closure Notification on Completion of ITAAC 2.3.02.08a.ii [Index Number 3021 Ladies and Gentlemen:

In accordance with 10 CFR 52.99(c)(1), the purpose of this letter is to notify the Nuclear Regulatory Commission (NRC) of the completion of Vogtle Electric Generating Plant (VEGP) Unit 3 and Unit 4 Inspections, Tests, Analyses, and Acceptance Criteria (ITAAC) Item 2.3.02.08a.ii [Index Number 302] for verifying the Chemical and Volume Control System (CVS) provides makeup water to the Reactor Coolant System (RCS). The closure process for this ITAAC is based on the guidance described in NEI 08-01, "Industry Guideline for the ITAAC Closure Process under 10 CFR Part 52,"

which was endorsed by the NRC in Regulatory Guide 1.215.

This letter contains no new NRC regulatory commitments. Southern Nuclear Operating Company (SNC) requests NRC staff confirmation of this determination and publication of the required notice in the Federal Register per 10 CFR 52.99.

If there are any questions, please contact Tom Petrak at 706-848-1575.

Respectfully submitted.

Michael J. Yox Regulatory Affairs Din Vogtle 3 & 4

Enclosure:

Vogtle Electric Generating Plant (VEGP) Unit 3 and Unit 4 Completion of ITAAC 2.3.02.08a.ii [Index Number 302]

MJY/GJL/sfr

U.S. Nuclear Regulatory Commission ND-19-0257 Page 2 of 3 To:

Southern Nuclear Operating Company/ Georgia Power Company M

M M

M M

M M

M D. A. Bost (w/o enclosures)

D. L. McKinney (w/o enclosures)

M. D. Meier (w/o enclosures)

D. H. Jones (w/o enclosures)

J. 8. Klecha G. Chick M. J. Yox A. 8. Parton Ms. K. A. Roberts Mr. T. G. Petrak Mr. W. A. Sparkman Mr. C. T. Defnall Mr. C. E. Morrow Mr. J. L. Hughes Ms. K. M. Stacy Ms. A. C. Chamberlain Mr. J. C. Haswell Document Services RTYPE: VND.LI.L06 File AR.01.02.06 cc:

Nuclear Reaulatorv Commission Mr. W. Jones (w/o enclosures)

Mr. F. D. Brown Ms. J. M. Heisserer Mr. C. P. Patel Mr. G. J. Khouri Ms. S. E. Temple Mr. N. D. Karlovich Mr. A. Lerch Mr. C. J. Even Mr. B. J. Kemker Ms. N. C. Coovert Mr. C. Welch Mr. I. Cozens Mr. J. Gaslevic Mr. V. Hall Oaiethorpe Power Corporation Mr. R. B. Brinkman Mr. E. Rasmussen Municipal Eiectric Authoritv of Georgia Mr. J. E. Fuller Mr. S. M. Jackson Daiton Utilities Mr. T. Bundros

U.S. Nuclear Regulatory Commission ND-19-0257 Page 3 of 3 Westinahouse Electric Company. LLC Dr. L. Oriani (w/o enclosures)

Mr. D. C. Durham (w/o enclosures)

Mr. M. M. Corletti Ms. L. G. Iller Ms. J. Monahan Mr. J. L. Coward Other Mr. J. E. Hesler, Bechtel Power Corporation Ms. L. Matis, Tetra Tech NUS, inc.

Dr. W. R. Jacobs, Jr., Ph.D., GDS Associates, Inc.

Mr. 8. Roetger, Georgia Public Service Commission Ms. 8. W. Kernizan, Georgia Public Service Commission Mr. K. C. Greene, Troutman Sanders Mr. 8. Blanton, Balch Bingham

U.S. Nuclear Regulatory Commission ND-1&-0257 Enclosure Page 1 of 3 Southern Nuclear Operating Company ND-19-0257 Enclosure Vogtle Electric Generating Plant (VEGP) Unit 3 and Unit 4 Completion of ITAAC 2.3.02.08a.ii [Index Number 302]

U.S. Nuclear Regulatory Commission ND-13-0257 Enclosure Page 2 of 3 ITAAC Statement Desion Commitment 8.a) The CVS provides makeup water to the RCS.

Insoections.Iests. Analvsis ii) Inspection of the boric acid storage tank volume will be performed.

Acceptance Criteria ii) The volume in the boric acid storage tank is at least 70,000 gallons between the tank suction point and the tank overflow.

ITAAC Determination Basis Multiple ITAAC are performed to demonstrate that the Chemical and Volume Control System (CVS) provides makeup water to the Reactor Coolant System (RCS). This ITAAC performs inspections to verify volumes in Unit 3 and Unit 4 boric acid storage tanks (BAST)(SV3-CVS-MT-01 and SV4-CVS-MT-01) are at least 70,000 gallons between the tank suction point and the tank overflow (i.e., usable volume).

Inspections of each BAST were performed by the vendor to demonstrate the Unit 3 and Unit 4 BAST usable volume. The BAST does not have an overflow line; however, an atmospheric vent line is installed on the top of the tank dome. As-built measurements of the individual tanks' outer circumference and distance from the bottom of each outlet pipe (suction point) to the top of each tanks' cylindrical shell were taken and recorded. These measurements were used to determine each tanks' volume considering the shell thickness and unavailable volume due to tank internals.

Each BAST volume was documented in the Unit 3 and Unit 4 Vendor Volume Calculations (Reference 1 and 2, respectively) which verify the boric acid storage tank volumes are 80,349 gallons each for both Unit 3 and Unit 4 and meets the ITAAC acceptance criteria.

Reference 1 and 2 are available for NRC inspection as part of the Unit 3 and Unit 4 ITAAC completion packages (Reference 3 and 4, respectively).

ITAAC Finding Review In accordance with plant procedures for ITAAC completion. Southern Nuclear Operating Company (SNC) performed a review of all ITAAC findings pertaining to the subject ITAAC and associated corrective actions. This review found that there are no relevant ITAAC findings associated with this ITAAC. The ITAAC completion reviews are documented in the ITAAC Completion Packages for ITAAC 2.3.02.08a.ii (Reference 3 and 4) and are available for NRC review.

U.S. Nuclear Regulatory Commission ND-19-0257 Enclosure Page 3 of 3 ITAAC Completion Statement Based on the above information, SNC hereby notifies the NRG that ITAAC 2.3.02.08a.ii was performed for VEGP Unit 3 and Unit 4 and that the prescribed acceptance criteria were met.

Systems, structures, and components verified as part of this ITAAC are being maintained in their as-designed, ITAAC compliant condition in accordance with approved plant programs and procedures.

References (available for NRG inspection)

1. SV3-MT5A-VDR-002, Rev. 0, "Vendor Volume Calculation"
2. SV4-MT5A-VDR-002, Rev. 0, "Vendor Volume Calculation"
3. 2.3.02.08a.ii-U3-CP-Rev 0, ITAAC Completion Package
4. 2.3.02.08a.ii-U4-CP-Rev 0, ITAAC Completion Package