ND-18-0321, Unit 4 - Resubmittal of Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.2.01.01 (Index Number 90)

From kanterella
(Redirected from ML18072A250)
Jump to navigation Jump to search
Unit 4 - Resubmittal of Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.2.01.01 (Index Number 90)
ML18072A250
Person / Time
Site: Vogtle  
Issue date: 03/13/2018
From: Yox M
Southern Nuclear Operating Co
To:
Document Control Desk, Office of New Reactors
References
ITAAC 2.2.01.01, ND-18-0321
Download: ML18072A250 (6)


Text

Southern Nuclear MAR 1 3 2018 Docket Nos.:

52-025 52-026 Michael J. Yox Regulatory Affairs Director Vogtie 3 & 4 7825 River Road Waynesboro, GA 30830 706-848-6459 tei 410-474-8587 ceii myox@southernco.com ND-18-0321 10CFR 52.99(c)(3)

U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001 Southern Nuclear Operating Company Vogtie Electric Generating Plant Unit 3 and Unit 4 Resubmittal of Notice of Uncompleted ITAAC 225-davs Prior to Initial Fuel Load Item 2.2.01.01 [Index Number 901 Ladies and Gentlemen:

Pursuant to 10 CFR 52.99(c)(3), Southern Nuclear Operating Company hereby notifies the NRC that as of March 6, 2018, Vogtie Electric Generating Plant (VEGP) Unit 3 and Unit 4 Uncompleted Inspections, Tests, Analyses, and Acceptance Criteria (ITAAC) Item 2.2.01.01 [Index Number90]

has not been completed greater than 225-days priorto initial fuel load. The Enclosure describes the plan for completing this ITAAC. Southern NuclearOperating Company will, at a later date, provide additional notifications for ITAAC that have not been completed 225-days prior to initial fuel load.

Southern Nuclear Operating Company (SNC) previously submitted Noticeof Uncompleted ITAAC 225-days Priorto Initial Fuel Loadfor Item2.2.01.01 [Index Number 90] ND-18-0099

[ML18045A284] dated February 14, 2018. This resubmittal supersedes ND-18-0099 in its entirety.

This notification is informed by the guidance described in NEI 08-01, Industry Guideline for the ITAAC Closure Process Under 10 CFR Part 52, which was endorsed by the NRC in Regulatory Guide 1.215. In accordance with NEI 08-01, this notification includes ITAACfor which required inspections, tests, or analyses have not been performedor have been only partially completed. All ITAAC will be fully completed and all Section 52.99(c)(1) ITAAC Closure Notifications will be submitted to NRC to support the Commission finding that all acceptance criteria are met priorto plant operation, as required by 10 CFR 52.103(g).

This letter contains no new NRC regulatory commitments.

If there are any questions, please contact Tom Petrak at 706-848-1575.

Respectfully submitted, Michael J. Yox Regulatory Affairs Director Vogtie 3 &4

Enclosure:

Vogtie Electric Generating Plant (VEGP) Unit 3 and Unit4 Completion Plan for Uncompleted ITAAC 2.2.01.01 [Index Number 90]

MJY/LBP/amw

U.S. Nuclear Regulatory Commission ND-18-0321 Page 2 of 3 To:

Southern Nuclear Operating Company/ Georgia Power Company Mr. D. A. Bost (w/o enclosures)

Mr. M. D. Rauckhorst (w/o enclosures)

Mr. M. D. Meier Mr. D. H. Jones (w/o enclosures)

Mr. D. L. McKinney Mr. M. J. Yox Mr. D. L. Fulton Mr. J. B. Klecha Mr. F. H. Willis Ms. A. L. Pugh Mr. A. 8. Parton Mr. W. A. Sparkman Mr. C. E. Morrow Ms. K. M. Stacy Mr. M. K. Washington Mr. J. P. Redd Ms. A. 0. Chamberlain Mr. D. R. Culver Mr. T. G. Petrak Document Services RTYPE: VND.LI.L06 File AR.01.02.06 cc:

Nuclear Reaulatorv Commission Mr. W. Jones (w/o enclosures)

Ms. J. M. Heisserer Mr. C. P. Patel Mr. M. E. Ernstes Mr. G. J. Khouri Mr. T. E. Chandler Ms. S. E. Temple Ms. P. Braxton Mr. N. D. Karlovich Mr. A. J. Lerch Mr. C. J. Even Mr. F. D. Brown Mr. B. J. Kemker Ms. A. E. Rivera-Varona Ms. L. A. Kent Mr. P. B. Donnelly Oalethoroe Power Corporation Mr. R. B. Brinkman Municipal Electric Authoritv of Georgia Mr. J. E. Fuller Mr. S. M. Jackson

U.S. Nuclear Regulatory Commission ND-18-0321 Page 3 of 3 Dalton Utilities Mr. T. Bundros Westinqhouse Electric Company. LLC Dr. L. Oriani (w/o enclosures)

Mr. D. 0. Durham (w/o enclosures)

Mr. M. M. Corletti Ms. L. G. Iller Mr. D. Hawkins Ms. J. Monahan Mr. J. L. Coward Ms. N. E. Deangelis Other Mr. J. E. Hosier, Bechtel Power Corporation Ms. L. Matis, Tetra Tech NUS, Inc.

Dr. W. R. Jacobs, Jr., Ph.D., GDS Associates, inc.

Mr. 8. Roetger, Georgia Public Service Commission Ms. 8. W. Kernizan, Georgia Public Service Commission Mr. K. C. Greene, Troutman Sanders Mr. 8. Blanton, Baich Bingham

U.S. Nuclear Regulatory Commission ND-18-0321 Enclosure Page 1 of 3 Southern Nuclear Operating Company ND-18-0321 Enclosure Vogtle Electric Generating Plant (VEGP) Unit 3 and Unit 4 Completion Plan for Uncompleted ITAAC 2.2.01.01 [Index Number 90]

U.S. Nuclear Regulatory Commission ND-18-0321 Enclosure Page 2 of 3 ITAAC Statement Design Commitment

1. The functional arrangement of the CNS and associated systems is as described inthe Design Description of this Section 2.2.1.

Inspections/Tests/Analvses Inspection of the as-built system will be performed.

Acceptance Criteria The as-built CNS conforms with the functional arrangement as described inthe Design Description of this Section 2.2.1.

ITAAC Completion Description An inspection of the as-built containment system (CNS) and associated systems isconducted after completion of construction toconfirm that thefunctional arrangement of theCNS andassociated systems is as described in theDesign Description of Combined License (COL) Appendix C, Section 2.2.1. This inspection encompassesthe structures, systems, and components (SSCs) identified in the COL Appendix C, Section2.2.1 Design Description, including those in Table 2.2.1-4 and Figure 2.2.1-1.

Theinspection (walkdown) iscompleted in accordance with APP-GW-ITY-004, Functional Arrangement ITAAC Guideline (Reference 1), which requires thepreparation of a detailed inspection plan. This inspection plan includes the use of detailed drawings such as Piping and Instrumentation Drawings (P&IDs) orSingle Line Elementary Drawings to perform visual observations and compare the as-built system to the Design Description.

The inspection results aredocumented in the Unit 3 and Unit 4 Principal Closure Documents XXX andYYY (References 2 and3, respectively) supporting the Unit 3 and Unit 4 ITAAC 2.2.01.01 Completion Packages (References 4 and 5, respectively) and verify that the SSCs are physically arranged and located toperform the functions described in the Design Description and referenced table andfigure. Theinspection results confirm thatthe as-built CNS andassociated systems conform with the functional arrangementas described inthe COL Appendix C, Section2.2.1, Design Description.

The Unit 3 and Unit 4 Principal Closure Documents XXX and YYY are available for NRC inspection as partofthe Unit 3 and Unit 4 ITAAC 2.2.01.01 Completion Packages.

List of ITAAC Findings In accordance with plant procedures for ITAAC completion. Southern Nuclear Operating Company (SNC) performed a review of all findings pertaining to the subject ITAAC and associated corrective actions. This review found there are no relevant ITAAC findings associated with this ITAAC.

U.S. Nuclear Regulatory Commission ND-18-0321 Enclosure Page 3 of 3 References favailable for NRG inspection) 1.

APP-GW-ITY-004, Functional Arrangement Guideline 2.

Principal Closure Document XXX (Unit 3) 3.

Principal Closure Document YYY (Unit 4) 4.

ITAAC 2.2.01.01 Completion Package (Unit 3) 5.

ITAAC 2.2.01.01 Completion Package (Unit 4) 6.

NEI 08-01, "Industry Guideline for the ITAAC Closure Process Under 10 CFR Part 52"