[b LOUISIANA ,4a cauncE S7m, m P O W E A & L 1 G H T! P o m sooa

  • NEW TALEANS LCVSIANA * (504) 3567C174 2345 UT:UT:ES SYSTEM January 23, 1981 W3P81-0076 Q-3-A20.03.14 Mr. Karl V. Seyfrit, Director, Region IV U. S. Nuclear Regulatory Cor=tission Office of Inspection and Enforcement 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76012

SUBJECT:

Uaterford 3 SES Docket No. 50-382 IE Bulletin No. 80-23 Failures of Solenoid Valves Manufactured by Valcor Engineering Corporation

Dear Mr. Seyfrit:

The subject IE Bulletin addresses the failure of Valcor solenoid valves having P/N's V70900-21-1 or -3. After evaluating the equipment purchased for Waterford 3, LP&L has concluded that no Valcor solenoid valves having P/N's V70900-21-1 or -3 are used to perfom any safety-related functions.

The =anpower expended in this review was 3 =andays.

If you have any questions, please advise.

Yours very truly, . . ,

~

  1. L-L. V. Maurin Project Director O[-@ti%