Forwards Safety Evaluation Re First 10-yr Interval Inservice Insp Plan Requests for Relief ISI-018 Through ISI-020 for Entergy Operations,Inc,Unit 3
ML20210D870
Person / Time
Site: Waterford Entergy icon.png
Issue date: 07/23/1999
From: Gramm R
NRC (Affiliation Not Assigned)
To: Dugger C
ENTERGY OPERATIONS, INC.
Shared Package
ML20210D875 List:
References
TAC-MA3380, NUDOCS 9907280055
Download: ML20210D870 (2)


Text

I Mr. Ch:rl:s M. Dugg:r

' Vic] Pr:sident Operations July 23, 1999 Ent:rgy Op:r;tions, Inc.  !

! P. O. Box B Killona, LA 70066

SUBJECT:

FIRST 10-YEAR INTERVAL INSERVICE INSPECTION PROGRAM PLAN  !

REQUESTS FOR RELIEF NOS. ISI-018 THROUGH 1S1-020 FOR WATERFORD STEAM ELECTRIC STATION, UNIT 3 (TAC NO. MA3380 )

Dear Mr. Dugger:

i The staff, with technical assistance from its contractor, the Idaho National Engineering and Environmental Laboratory (INEEL), has reWewed and evaluated the information provided by Entergy Operations, Inc. (licensee), in its letter dated June 30,1998, proposing its First 10-Year Interval Inservice inspection Requests for Relief Nos. ISI-018 through ISI-020 for Waterford ,

Steam Electric Station, Unit 3. I For Requests for Relief ISI-019 and ISI-020, imposition of the requirements in strict compliance l with the American Society of Mechanical Engineers Boiler and Pressure Vessel Code is impractical. Examinations performed provide reasonable assurance of the structuralintegrity.

Therefore, relief is granted pursuant to Title 10 of the Code of Federal Reaulations.

Section 50.55a(g)(6)(i) (10 CFR 50.55a(g)(6)(i)).

For Request for Relief ISI-018, the licensee has made a reasonable effort to maximize examination coverage of the shell welds for the augmented reactor pressure vessel examination. The examinations performed provide an acceptable level of quality and safety.

Therefore, the licensee's proposed alternative is authorized pursuant to 10 CFR 50.55a(g)(6)(ii)(A)(5).

The statt's evaluation and conclusions are contained in the enclosed Safety Evaluation (SE).

INEEL's Tea.hnical Letter Report is also included as an attachment to the etaff's SE.

Sincerely, 1 ORIGINAL SIGNED BY l Robert A. Gramm, Chief, Section 1 Project Directorate IV & Decommissioning

~

9907280055 990723 Division of Licensing Project Management PDR ADOCK 05000382 Office of Nuclear Reactor Regulation i P PDR l Docket No. 50-382  ;

I

Enclosure:

Safety Evaluation [' t *

. t I

},

cc w/ encl: See next page hg f!

DISTRIBUTION: ,n (Docket FileM PUBLIC T~

PD#iv-1 Reading S.Richards g~) l R. Scholl (RFS, SE only) OGC G. Hill (2) ACRS D.Lange, RIV K.Brockmen, RIV I To receive a copy of this document, indicate "C" in the box l OFFICE PDlV-1/PM, f PDIV-1/LA, n L OGOM PDIV-1/SC  ;

NAME CPatel:dbY Lperry h fdreh/Wo RGramm b DATE *1 / ~7 /99 / h99 9 / d /99 1/D /99 G:\PDIV-1\Waterford\REL3380 wpd dog:UMEIATgME:

..bJUU4 OFFICIAL RECORD COPY

Waterford Generating Station 3 cc:

Administrator Regional Administrator, Region IV Louisiana Radiation Protection Division U.S. Nuclear Regulatory Commission P. O. Box 82135 611 Ryan Plaza Drive, Suite 1000 Baton Rouge, LA 70884 2135 Arlington, TX 76011 Vice President, Operations Support Parish President Council Entergy Operations, Inc. St. Charles Parish P. O. Box 31995 P. O. Box 302 Jackson, MS 39286 Hahnville, LA 70067 Director Executive Vice-President Nuclear Safety & Regulatory Affairs and Chief Operating Officer )

Entergy Operations, Inc. Entergy Operations, Inc.

P. O. Box B P. O. Box 31995 Killona, LA 70066 Jackson, MS 39286-1995 Wise, Carter, Child & Caraway Chairman P. O. Box 651 Louisiana Public Service Commission Jackson, MS 39205 One American Place, Suite 1630 Baton Rouge, LA 70825-1697 General Manager Plant Operations Entergy Operations, Inc.

P. O. Box B Killona, LA 70066 Licensing Manager Entergy Operations, Inc. ,

P. O. Box B l Killona, LA 70066 Winston & Strawn

! 1400 L Street, N.W.

Washington, DC 20005-3502 l Resident inspector /Waterford NPS l

Post Office Box 822 Killona, LA 70066 May 1999 l