Category:INSPECTION REPORT
MONTHYEARIR 05000327/19990051999-09-27027 September 1999 Insp Repts 50-327/99-05 & 50-328/99-05 on 990718-0828. Violations Noted.Major Areas Inspected:Mitigating Sys ML20210V1621999-08-13013 August 1999 Insp Repts 50-327/99-04 & 50-328/99-04 on 990601-0717.One Potentially Safety Significant Issue Noted.Major Areas Inspected:Licensee Emergency Preparedness IR 05000327/19990031999-06-30030 June 1999 Insp Repts 50-327/99-03 & 50-328/99-03 on 990328-0531.Non- Cited Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Maint & Engineering IR 05000327/19990021999-04-23023 April 1999 Insp Repts 50-327/99-02 & 50-328/99-02 on 990214-0327.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint & Engineering IR 05000327/19990011999-03-15015 March 1999 Insp Repts 50-327/99-01 & 50-328/99-01 on 990103-0213. Violations Noted & Being Treated as non-cited Violations. Major Areas Inspected:Aspects of Licensee Operations,Maint & Engineering IR 05000327/19980111999-02-0101 February 1999 Insp Repts 50-327/98-11 & 50-328/98-11 on 981122-990102. Violations Noted.Major Areas Inspected:Licensee Operations, Maint & Engineering IR 05000327/19980101998-12-0707 December 1998 Insp Repts 50-327/98-10 & 50-328/98-10 on 981011-1121.No Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000327/19980141998-12-0404 December 1998 Insp Repts 50-327/98-14 & 50-328/98-14 on 981102-06.No Violations Noted.Major Areas Inspected:Observation & Evaluation of Biennial Emergency Preparedness Exercise for Sequoyah Nuclear Plan IR 05000327/19980131998-11-24024 November 1998 Insp Repts 50-327/98-13 & 50-328/98-13 on 980914-1016. Violations Noted.Major Areas Inspected:Aspects of Licensee maint,testing,engineering,self-assessment & Problem Evaluations of Licensee Ice Condenser Sys IR 05000327/19980091998-11-0909 November 1998 Insp Repts 50-327/98-09 & 50-328/98-09 on 980830-1010. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering Plant Support & Effectiveness of Licensee Controls in Identifying,Resolving & Preventing Problems IR 05000327/19980081998-09-18018 September 1998 Insp Repts 50-327/98-08 & 50-328/98-08 on 980719-0829.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support,Licensee Conducted Radiological Emergency Plan Drill IR 05000327/19980071998-08-0404 August 1998 Insp Repts 50-327/98-07 & 50-328/98-07 on 980607-0718. Violations Noted.Major Areas Inspected:Aspects of Licensee Operation,Maint,Engineering,Plant Support & Effectiveness of Licensee Controls in Identifying & Preventing Problems ML20236J6631998-06-26026 June 1998 Insp Repts 50-327/98-06 & 50-328/98-06 on 980426-0606. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000327/19980051998-06-12012 June 1998 Insp Repts 50-327/98-05 & 50-328/98-05 on 980504-08.No Violations Noted.Major Areas Inspected:Maint Procedure.Insp Team Comprised Region II & Headquarters Personnel.Switchgear & Surrounding Areas Found in Good Matl Condition IR 05000327/19980041998-05-15015 May 1998 Insp Repts 50-327/98-04 & 50-328/98-04 on 980315-0425. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20216H7841998-04-10010 April 1998 Insp Repts 50-327/98-03 & 50-328/98-03 on 980201-0314. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20217K3801998-03-30030 March 1998 Insp Repts 50-327/98-01 & 50-328/98-01 on 980126-0213.No Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000327/19980021998-03-0505 March 1998 Insp Repts 50-327/98-02 & 50-328/98-02 on 980202-06.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations & Maint.Review of Initial & Requalification Training Programs Were Also Conducted ML20203J5541998-02-19019 February 1998 Insp Repts 50-327/97-18 & 50-328/97-18 on 971221-980131. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering,Plant Support & Effectiveness of Licensee Controls in Identifying & Resolving Problems IR 05000327/19970171998-01-16016 January 1998 Insp Repts 50-327/97-17 & 50-328/97-17 on 971109-1220.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering,Plant Support & Effectiveness of Licensee Controls in Identifying,Resolving & Preventing Problems IR 05000327/19970141997-12-0808 December 1997 Insp Repts 50-327/97-14 & 50-328/97-14 on 970928-1108.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering,Plant Support,Effectiveness of License Controls in Identifying,Resolving & Preventing Problems IR 05000327/19970161997-12-0505 December 1997 Insp Repts 50-327/97-16 & 50-328/97-16 on 971103-06.No Violations Noted.Major Areas Inspected:Evaluation of 971017 Wire Damage Event at Electrical Penetration 22 IR 05000327/19970121997-10-24024 October 1997 Insp Repts 50-327/97-12 & 50-328/97-12 on 970824-0927.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support & Operator Requalification Program IR 05000327/19970151997-10-23023 October 1997 Insp Repts 50-327/97-15 & 50-328/97-15 on 970922-29.No Violations Noted.Major Areas Inspected:Emergency Preparedness IR 05000327/19970081997-09-22022 September 1997 Insp Repts 50-327/97-08 & 50-328/97-08 on 970706-0823. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering,Plant Support & Effectiveness of Licensee Controls in Identifying,Resolving & Preventing Problems IR 05000327/19970091997-09-15015 September 1997 Insp Repts 50-327/97-09 & 50-328/97-09 on 970804-08.No Violations Noted.Major Areas Inspected:Operations,Maint & Engineering Re Effectiveness of Licensee Controls in Identifying,Resolving & Preventing Problems ML20198H7911997-09-11011 September 1997 Insp Repts 50-327/97-13 & 50-328/97-13 on 970725-0904. Violations Noted.Major Areas Inspected:Insp Scope,Event Synopsis & Observations & Findings ML20141H9581997-07-28028 July 1997 Insp Repts 50-327/97-06 & 50-328/97-06 on 970525-0705. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000327/19970071997-07-24024 July 1997 Insp Repts 50-327/97-07 & 50-328/97-07 on 970623-27. Violations Noted.Major Areas Inspected:Aspects of Licensee Plant Support ML20141G0441997-06-20020 June 1997 Insp Repts 50-327/97-04 & 50-328/97-04 on 970413-0524. Violations Noted.Major Areas Inspected:Operations Re Physics Testing,Maint,Engineering & Plant Support ML20148F9631997-05-27027 May 1997 Special Insp Repts 50-327/97-05 & 50-328/97-05 on 970324-0522.Violations Noted.Major Areas Inspected:Events Associated W/Unit 1 Inadvertent RCS Drain Down on 970324 ML20141C9881997-05-12012 May 1997 Insp Repts 50-327/97-03 & 50-328/97-03 on 970302-0412. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000327/19970021997-03-24024 March 1997 Insp Repts 50-327/97-02 & 50-328/97-02 on 970203-14.No Violations Noted.Major Areas Inspected:Detailed Reviews of Corrective Actions 14-1,14-2,14-3,15 & 16 ML20137F7081997-03-18018 March 1997 Insp Repts 50-327/97-01 & 50-328/97-01 on 970119-0301. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering,Plant Support & Effectiveness of Licensee Controls in Identifying & Preventing Problems IR 05000327/19960171997-02-14014 February 1997 Insp Repts 50-327/96-17 & 50-328/96-17 on 961208-970118.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering,Plant Support & Plant Status ML20134G1851997-01-13013 January 1997 Insp Repts 50-327/96-16 & 50-328/96-16 on 960923-1219. Violations Noted.Major Areas Inspected:Review of Corrective Actions Implemented for Problem Evaluation Repts IR 05000327/19960141996-12-31031 December 1996 Insp Repts 50-327/96-14 & 50-328/96-14 on 961027-1207.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000327/19960151996-12-23023 December 1996 Insp Repts 50-327/96-15 & 50-328/96-15 on 961104-08.No Violations Noted.Major Areas Inspected:Control Room Simulator,Tsc,Osc,Cecc & Joint Info Ctr of Biennial Emergency Preparedness Exercise ML20134Q1721996-11-25025 November 1996 Insp Repts 50-327/96-13 & 50-328/96-13 on 960919-1102. Violations Noted.Major Areas Inspected:Events Associated W/Reactor Shutdown & Subsequent Manual Tripping of Unit 2 on 961011 IR 05000327/19960111996-11-19019 November 1996 Insp Repts 50-327/96-11 & 50-328/96-11 on 960915-1026. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering,Plant Support, & Effectiveness of Licensee Controls in Identifying,Resolving & Preventing Problems ML20134Q3301996-11-19019 November 1996 Insp Repts 50-327/96-11 & 50-328/96-11 on 960915-1026. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering,Plant Support, & Effectiveness of Licensee Controls in Identifying,Resolving & Preventing Problems ML20129A2141996-10-10010 October 1996 Insp Repts 50-327/96-09 & 50-328/96-09 on 960728-0914. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20128H8021996-09-27027 September 1996 Insp Repts 50-327/96-10 & 50-328/96-10 on 960708,10-12 & 0819-22.Non Cited Violations Noted.Major Areas Inspected: Plant FP Program & Action Taken of Insp Findings Previously Identified IR 05000327/19930521993-12-23023 December 1993 Insp Repts 50-327/93-52 & 50-328/93-52 on 931107-1204. Violations Noted.Major Areas Inspected:Plant Operations, Maint,Plant Surveillance,Evaluation of Licensee self-assessment Capability & LER Closeout IR 05000327/19930371993-12-17017 December 1993 Insp Repts 50-327/93-37 & 50-328/93-37 on 931115-19. Violations Noted.Major Areas Inspected:Operator Requalification Program,Exam Development & Administration & Training Staff Qualifications & Training IR 05000327/19930531993-12-17017 December 1993 Insp Repts 50-327/93-53 & 50-328/93-53 on 931115-19.No Violations Noted.Major Areas Inspected:Meteorological Monitoring,Control Room Emergency Ventilation,Audits & Secondary Water Chemistry IR 05000327/19930511993-12-13013 December 1993 Partially Withheld Insp Repts 50-327/93-51 & 50-328/93-51 on 931115-19 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Mgt Support,Security Program Plans & Implementing Procedures & Security Program Audit IR 05000327/19930501993-11-24024 November 1993 Insp Repts 50-327/93-50 & 50-328/93-50 on 931011-1106. Violations Noted.Major Areas Inspected:Plant Operations, Plant Maintenance,Plant Surveillance,Evaluation of Licensee self-assessment Capability & LER Closeout IR 05000327/19930421993-11-0909 November 1993 Insp Repts 50-327/93-42 & 50-328/93-42 on 930904-1010. Violations Noted.Major Areas Inspected:Plant Operations, Maint & Surveillance,Evaluation of Licensee self-assessment Capability & Licensee Event Rept Closeout IR 05000327/19930481993-11-0909 November 1993 Insp Repts 50-327/93-48 & 50-328/93-48 on 931006-08. Violation Noted.Major Areas Inspected:Qualifications of Acting Lab Supervisor,Use of Expired Stds in Alcohol breath-analysis Equipment & Testing Lab Procedures 1999-09-27
[Table view] Category:NRC-GENERATED
MONTHYEARIR 05000327/19990051999-09-27027 September 1999 Insp Repts 50-327/99-05 & 50-328/99-05 on 990718-0828. Violations Noted.Major Areas Inspected:Mitigating Sys ML20210V1621999-08-13013 August 1999 Insp Repts 50-327/99-04 & 50-328/99-04 on 990601-0717.One Potentially Safety Significant Issue Noted.Major Areas Inspected:Licensee Emergency Preparedness IR 05000327/19990031999-06-30030 June 1999 Insp Repts 50-327/99-03 & 50-328/99-03 on 990328-0531.Non- Cited Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Maint & Engineering IR 05000327/19990021999-04-23023 April 1999 Insp Repts 50-327/99-02 & 50-328/99-02 on 990214-0327.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint & Engineering IR 05000327/19990011999-03-15015 March 1999 Insp Repts 50-327/99-01 & 50-328/99-01 on 990103-0213. Violations Noted & Being Treated as non-cited Violations. Major Areas Inspected:Aspects of Licensee Operations,Maint & Engineering IR 05000327/19980111999-02-0101 February 1999 Insp Repts 50-327/98-11 & 50-328/98-11 on 981122-990102. Violations Noted.Major Areas Inspected:Licensee Operations, Maint & Engineering IR 05000327/19980101998-12-0707 December 1998 Insp Repts 50-327/98-10 & 50-328/98-10 on 981011-1121.No Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000327/19980141998-12-0404 December 1998 Insp Repts 50-327/98-14 & 50-328/98-14 on 981102-06.No Violations Noted.Major Areas Inspected:Observation & Evaluation of Biennial Emergency Preparedness Exercise for Sequoyah Nuclear Plan IR 05000327/19980131998-11-24024 November 1998 Insp Repts 50-327/98-13 & 50-328/98-13 on 980914-1016. Violations Noted.Major Areas Inspected:Aspects of Licensee maint,testing,engineering,self-assessment & Problem Evaluations of Licensee Ice Condenser Sys IR 05000327/19980091998-11-0909 November 1998 Insp Repts 50-327/98-09 & 50-328/98-09 on 980830-1010. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering Plant Support & Effectiveness of Licensee Controls in Identifying,Resolving & Preventing Problems IR 05000327/19980081998-09-18018 September 1998 Insp Repts 50-327/98-08 & 50-328/98-08 on 980719-0829.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support,Licensee Conducted Radiological Emergency Plan Drill IR 05000327/19980071998-08-0404 August 1998 Insp Repts 50-327/98-07 & 50-328/98-07 on 980607-0718. Violations Noted.Major Areas Inspected:Aspects of Licensee Operation,Maint,Engineering,Plant Support & Effectiveness of Licensee Controls in Identifying & Preventing Problems ML20236J6631998-06-26026 June 1998 Insp Repts 50-327/98-06 & 50-328/98-06 on 980426-0606. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000327/19980051998-06-12012 June 1998 Insp Repts 50-327/98-05 & 50-328/98-05 on 980504-08.No Violations Noted.Major Areas Inspected:Maint Procedure.Insp Team Comprised Region II & Headquarters Personnel.Switchgear & Surrounding Areas Found in Good Matl Condition IR 05000327/19980041998-05-15015 May 1998 Insp Repts 50-327/98-04 & 50-328/98-04 on 980315-0425. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20216H7841998-04-10010 April 1998 Insp Repts 50-327/98-03 & 50-328/98-03 on 980201-0314. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20217K3801998-03-30030 March 1998 Insp Repts 50-327/98-01 & 50-328/98-01 on 980126-0213.No Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000327/19980021998-03-0505 March 1998 Insp Repts 50-327/98-02 & 50-328/98-02 on 980202-06.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations & Maint.Review of Initial & Requalification Training Programs Were Also Conducted ML20203J5541998-02-19019 February 1998 Insp Repts 50-327/97-18 & 50-328/97-18 on 971221-980131. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering,Plant Support & Effectiveness of Licensee Controls in Identifying & Resolving Problems IR 05000327/19970171998-01-16016 January 1998 Insp Repts 50-327/97-17 & 50-328/97-17 on 971109-1220.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering,Plant Support & Effectiveness of Licensee Controls in Identifying,Resolving & Preventing Problems IR 05000327/19970141997-12-0808 December 1997 Insp Repts 50-327/97-14 & 50-328/97-14 on 970928-1108.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering,Plant Support,Effectiveness of License Controls in Identifying,Resolving & Preventing Problems IR 05000327/19970161997-12-0505 December 1997 Insp Repts 50-327/97-16 & 50-328/97-16 on 971103-06.No Violations Noted.Major Areas Inspected:Evaluation of 971017 Wire Damage Event at Electrical Penetration 22 IR 05000327/19970121997-10-24024 October 1997 Insp Repts 50-327/97-12 & 50-328/97-12 on 970824-0927.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support & Operator Requalification Program IR 05000327/19970151997-10-23023 October 1997 Insp Repts 50-327/97-15 & 50-328/97-15 on 970922-29.No Violations Noted.Major Areas Inspected:Emergency Preparedness IR 05000327/19970081997-09-22022 September 1997 Insp Repts 50-327/97-08 & 50-328/97-08 on 970706-0823. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering,Plant Support & Effectiveness of Licensee Controls in Identifying,Resolving & Preventing Problems IR 05000327/19970091997-09-15015 September 1997 Insp Repts 50-327/97-09 & 50-328/97-09 on 970804-08.No Violations Noted.Major Areas Inspected:Operations,Maint & Engineering Re Effectiveness of Licensee Controls in Identifying,Resolving & Preventing Problems ML20198H7911997-09-11011 September 1997 Insp Repts 50-327/97-13 & 50-328/97-13 on 970725-0904. Violations Noted.Major Areas Inspected:Insp Scope,Event Synopsis & Observations & Findings ML20141H9581997-07-28028 July 1997 Insp Repts 50-327/97-06 & 50-328/97-06 on 970525-0705. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000327/19970071997-07-24024 July 1997 Insp Repts 50-327/97-07 & 50-328/97-07 on 970623-27. Violations Noted.Major Areas Inspected:Aspects of Licensee Plant Support ML20141G0441997-06-20020 June 1997 Insp Repts 50-327/97-04 & 50-328/97-04 on 970413-0524. Violations Noted.Major Areas Inspected:Operations Re Physics Testing,Maint,Engineering & Plant Support ML20148F9631997-05-27027 May 1997 Special Insp Repts 50-327/97-05 & 50-328/97-05 on 970324-0522.Violations Noted.Major Areas Inspected:Events Associated W/Unit 1 Inadvertent RCS Drain Down on 970324 ML20141C9881997-05-12012 May 1997 Insp Repts 50-327/97-03 & 50-328/97-03 on 970302-0412. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000327/19970021997-03-24024 March 1997 Insp Repts 50-327/97-02 & 50-328/97-02 on 970203-14.No Violations Noted.Major Areas Inspected:Detailed Reviews of Corrective Actions 14-1,14-2,14-3,15 & 16 ML20137F7081997-03-18018 March 1997 Insp Repts 50-327/97-01 & 50-328/97-01 on 970119-0301. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering,Plant Support & Effectiveness of Licensee Controls in Identifying & Preventing Problems IR 05000327/19960171997-02-14014 February 1997 Insp Repts 50-327/96-17 & 50-328/96-17 on 961208-970118.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering,Plant Support & Plant Status ML20134G1851997-01-13013 January 1997 Insp Repts 50-327/96-16 & 50-328/96-16 on 960923-1219. Violations Noted.Major Areas Inspected:Review of Corrective Actions Implemented for Problem Evaluation Repts IR 05000327/19960141996-12-31031 December 1996 Insp Repts 50-327/96-14 & 50-328/96-14 on 961027-1207.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000327/19960151996-12-23023 December 1996 Insp Repts 50-327/96-15 & 50-328/96-15 on 961104-08.No Violations Noted.Major Areas Inspected:Control Room Simulator,Tsc,Osc,Cecc & Joint Info Ctr of Biennial Emergency Preparedness Exercise ML20134Q1721996-11-25025 November 1996 Insp Repts 50-327/96-13 & 50-328/96-13 on 960919-1102. Violations Noted.Major Areas Inspected:Events Associated W/Reactor Shutdown & Subsequent Manual Tripping of Unit 2 on 961011 IR 05000327/19960111996-11-19019 November 1996 Insp Repts 50-327/96-11 & 50-328/96-11 on 960915-1026. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering,Plant Support, & Effectiveness of Licensee Controls in Identifying,Resolving & Preventing Problems ML20134Q3301996-11-19019 November 1996 Insp Repts 50-327/96-11 & 50-328/96-11 on 960915-1026. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering,Plant Support, & Effectiveness of Licensee Controls in Identifying,Resolving & Preventing Problems ML20129A2141996-10-10010 October 1996 Insp Repts 50-327/96-09 & 50-328/96-09 on 960728-0914. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20128H8021996-09-27027 September 1996 Insp Repts 50-327/96-10 & 50-328/96-10 on 960708,10-12 & 0819-22.Non Cited Violations Noted.Major Areas Inspected: Plant FP Program & Action Taken of Insp Findings Previously Identified IR 05000327/19930521993-12-23023 December 1993 Insp Repts 50-327/93-52 & 50-328/93-52 on 931107-1204. Violations Noted.Major Areas Inspected:Plant Operations, Maint,Plant Surveillance,Evaluation of Licensee self-assessment Capability & LER Closeout IR 05000327/19930371993-12-17017 December 1993 Insp Repts 50-327/93-37 & 50-328/93-37 on 931115-19. Violations Noted.Major Areas Inspected:Operator Requalification Program,Exam Development & Administration & Training Staff Qualifications & Training IR 05000327/19930531993-12-17017 December 1993 Insp Repts 50-327/93-53 & 50-328/93-53 on 931115-19.No Violations Noted.Major Areas Inspected:Meteorological Monitoring,Control Room Emergency Ventilation,Audits & Secondary Water Chemistry IR 05000327/19930511993-12-13013 December 1993 Partially Withheld Insp Repts 50-327/93-51 & 50-328/93-51 on 931115-19 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Mgt Support,Security Program Plans & Implementing Procedures & Security Program Audit IR 05000327/19930501993-11-24024 November 1993 Insp Repts 50-327/93-50 & 50-328/93-50 on 931011-1106. Violations Noted.Major Areas Inspected:Plant Operations, Plant Maintenance,Plant Surveillance,Evaluation of Licensee self-assessment Capability & LER Closeout IR 05000327/19930421993-11-0909 November 1993 Insp Repts 50-327/93-42 & 50-328/93-42 on 930904-1010. Violations Noted.Major Areas Inspected:Plant Operations, Maint & Surveillance,Evaluation of Licensee self-assessment Capability & Licensee Event Rept Closeout IR 05000327/19930481993-11-0909 November 1993 Insp Repts 50-327/93-48 & 50-328/93-48 on 931006-08. Violation Noted.Major Areas Inspected:Qualifications of Acting Lab Supervisor,Use of Expired Stds in Alcohol breath-analysis Equipment & Testing Lab Procedures 1999-09-27
[Table view] Category:INSPECTION REPORT
MONTHYEARIR 05000327/19990051999-09-27027 September 1999 Insp Repts 50-327/99-05 & 50-328/99-05 on 990718-0828. Violations Noted.Major Areas Inspected:Mitigating Sys ML20210V1621999-08-13013 August 1999 Insp Repts 50-327/99-04 & 50-328/99-04 on 990601-0717.One Potentially Safety Significant Issue Noted.Major Areas Inspected:Licensee Emergency Preparedness IR 05000327/19990031999-06-30030 June 1999 Insp Repts 50-327/99-03 & 50-328/99-03 on 990328-0531.Non- Cited Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Maint & Engineering IR 05000327/19990021999-04-23023 April 1999 Insp Repts 50-327/99-02 & 50-328/99-02 on 990214-0327.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint & Engineering IR 05000327/19990011999-03-15015 March 1999 Insp Repts 50-327/99-01 & 50-328/99-01 on 990103-0213. Violations Noted & Being Treated as non-cited Violations. Major Areas Inspected:Aspects of Licensee Operations,Maint & Engineering IR 05000327/19980111999-02-0101 February 1999 Insp Repts 50-327/98-11 & 50-328/98-11 on 981122-990102. Violations Noted.Major Areas Inspected:Licensee Operations, Maint & Engineering IR 05000327/19980101998-12-0707 December 1998 Insp Repts 50-327/98-10 & 50-328/98-10 on 981011-1121.No Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000327/19980141998-12-0404 December 1998 Insp Repts 50-327/98-14 & 50-328/98-14 on 981102-06.No Violations Noted.Major Areas Inspected:Observation & Evaluation of Biennial Emergency Preparedness Exercise for Sequoyah Nuclear Plan IR 05000327/19980131998-11-24024 November 1998 Insp Repts 50-327/98-13 & 50-328/98-13 on 980914-1016. Violations Noted.Major Areas Inspected:Aspects of Licensee maint,testing,engineering,self-assessment & Problem Evaluations of Licensee Ice Condenser Sys IR 05000327/19980091998-11-0909 November 1998 Insp Repts 50-327/98-09 & 50-328/98-09 on 980830-1010. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering Plant Support & Effectiveness of Licensee Controls in Identifying,Resolving & Preventing Problems IR 05000327/19980081998-09-18018 September 1998 Insp Repts 50-327/98-08 & 50-328/98-08 on 980719-0829.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support,Licensee Conducted Radiological Emergency Plan Drill IR 05000327/19980071998-08-0404 August 1998 Insp Repts 50-327/98-07 & 50-328/98-07 on 980607-0718. Violations Noted.Major Areas Inspected:Aspects of Licensee Operation,Maint,Engineering,Plant Support & Effectiveness of Licensee Controls in Identifying & Preventing Problems ML20236J6631998-06-26026 June 1998 Insp Repts 50-327/98-06 & 50-328/98-06 on 980426-0606. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000327/19980051998-06-12012 June 1998 Insp Repts 50-327/98-05 & 50-328/98-05 on 980504-08.No Violations Noted.Major Areas Inspected:Maint Procedure.Insp Team Comprised Region II & Headquarters Personnel.Switchgear & Surrounding Areas Found in Good Matl Condition IR 05000327/19980041998-05-15015 May 1998 Insp Repts 50-327/98-04 & 50-328/98-04 on 980315-0425. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20216H7841998-04-10010 April 1998 Insp Repts 50-327/98-03 & 50-328/98-03 on 980201-0314. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20217K3801998-03-30030 March 1998 Insp Repts 50-327/98-01 & 50-328/98-01 on 980126-0213.No Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000327/19980021998-03-0505 March 1998 Insp Repts 50-327/98-02 & 50-328/98-02 on 980202-06.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations & Maint.Review of Initial & Requalification Training Programs Were Also Conducted ML20203J5541998-02-19019 February 1998 Insp Repts 50-327/97-18 & 50-328/97-18 on 971221-980131. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering,Plant Support & Effectiveness of Licensee Controls in Identifying & Resolving Problems IR 05000327/19970171998-01-16016 January 1998 Insp Repts 50-327/97-17 & 50-328/97-17 on 971109-1220.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering,Plant Support & Effectiveness of Licensee Controls in Identifying,Resolving & Preventing Problems IR 05000327/19970141997-12-0808 December 1997 Insp Repts 50-327/97-14 & 50-328/97-14 on 970928-1108.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering,Plant Support,Effectiveness of License Controls in Identifying,Resolving & Preventing Problems IR 05000327/19970161997-12-0505 December 1997 Insp Repts 50-327/97-16 & 50-328/97-16 on 971103-06.No Violations Noted.Major Areas Inspected:Evaluation of 971017 Wire Damage Event at Electrical Penetration 22 IR 05000327/19970121997-10-24024 October 1997 Insp Repts 50-327/97-12 & 50-328/97-12 on 970824-0927.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support & Operator Requalification Program IR 05000327/19970151997-10-23023 October 1997 Insp Repts 50-327/97-15 & 50-328/97-15 on 970922-29.No Violations Noted.Major Areas Inspected:Emergency Preparedness IR 05000327/19970081997-09-22022 September 1997 Insp Repts 50-327/97-08 & 50-328/97-08 on 970706-0823. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering,Plant Support & Effectiveness of Licensee Controls in Identifying,Resolving & Preventing Problems IR 05000327/19970091997-09-15015 September 1997 Insp Repts 50-327/97-09 & 50-328/97-09 on 970804-08.No Violations Noted.Major Areas Inspected:Operations,Maint & Engineering Re Effectiveness of Licensee Controls in Identifying,Resolving & Preventing Problems ML20198H7911997-09-11011 September 1997 Insp Repts 50-327/97-13 & 50-328/97-13 on 970725-0904. Violations Noted.Major Areas Inspected:Insp Scope,Event Synopsis & Observations & Findings ML20141H9581997-07-28028 July 1997 Insp Repts 50-327/97-06 & 50-328/97-06 on 970525-0705. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000327/19970071997-07-24024 July 1997 Insp Repts 50-327/97-07 & 50-328/97-07 on 970623-27. Violations Noted.Major Areas Inspected:Aspects of Licensee Plant Support ML20141G0441997-06-20020 June 1997 Insp Repts 50-327/97-04 & 50-328/97-04 on 970413-0524. Violations Noted.Major Areas Inspected:Operations Re Physics Testing,Maint,Engineering & Plant Support ML20148F9631997-05-27027 May 1997 Special Insp Repts 50-327/97-05 & 50-328/97-05 on 970324-0522.Violations Noted.Major Areas Inspected:Events Associated W/Unit 1 Inadvertent RCS Drain Down on 970324 ML20141C9881997-05-12012 May 1997 Insp Repts 50-327/97-03 & 50-328/97-03 on 970302-0412. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000327/19970021997-03-24024 March 1997 Insp Repts 50-327/97-02 & 50-328/97-02 on 970203-14.No Violations Noted.Major Areas Inspected:Detailed Reviews of Corrective Actions 14-1,14-2,14-3,15 & 16 ML20137F7081997-03-18018 March 1997 Insp Repts 50-327/97-01 & 50-328/97-01 on 970119-0301. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering,Plant Support & Effectiveness of Licensee Controls in Identifying & Preventing Problems IR 05000327/19960171997-02-14014 February 1997 Insp Repts 50-327/96-17 & 50-328/96-17 on 961208-970118.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering,Plant Support & Plant Status ML20134G1851997-01-13013 January 1997 Insp Repts 50-327/96-16 & 50-328/96-16 on 960923-1219. Violations Noted.Major Areas Inspected:Review of Corrective Actions Implemented for Problem Evaluation Repts IR 05000327/19960141996-12-31031 December 1996 Insp Repts 50-327/96-14 & 50-328/96-14 on 961027-1207.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000327/19960151996-12-23023 December 1996 Insp Repts 50-327/96-15 & 50-328/96-15 on 961104-08.No Violations Noted.Major Areas Inspected:Control Room Simulator,Tsc,Osc,Cecc & Joint Info Ctr of Biennial Emergency Preparedness Exercise ML20134Q1721996-11-25025 November 1996 Insp Repts 50-327/96-13 & 50-328/96-13 on 960919-1102. Violations Noted.Major Areas Inspected:Events Associated W/Reactor Shutdown & Subsequent Manual Tripping of Unit 2 on 961011 IR 05000327/19960111996-11-19019 November 1996 Insp Repts 50-327/96-11 & 50-328/96-11 on 960915-1026. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering,Plant Support, & Effectiveness of Licensee Controls in Identifying,Resolving & Preventing Problems ML20134Q3301996-11-19019 November 1996 Insp Repts 50-327/96-11 & 50-328/96-11 on 960915-1026. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering,Plant Support, & Effectiveness of Licensee Controls in Identifying,Resolving & Preventing Problems ML20129A2141996-10-10010 October 1996 Insp Repts 50-327/96-09 & 50-328/96-09 on 960728-0914. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20128H8021996-09-27027 September 1996 Insp Repts 50-327/96-10 & 50-328/96-10 on 960708,10-12 & 0819-22.Non Cited Violations Noted.Major Areas Inspected: Plant FP Program & Action Taken of Insp Findings Previously Identified IR 05000327/19930521993-12-23023 December 1993 Insp Repts 50-327/93-52 & 50-328/93-52 on 931107-1204. Violations Noted.Major Areas Inspected:Plant Operations, Maint,Plant Surveillance,Evaluation of Licensee self-assessment Capability & LER Closeout IR 05000327/19930371993-12-17017 December 1993 Insp Repts 50-327/93-37 & 50-328/93-37 on 931115-19. Violations Noted.Major Areas Inspected:Operator Requalification Program,Exam Development & Administration & Training Staff Qualifications & Training IR 05000327/19930531993-12-17017 December 1993 Insp Repts 50-327/93-53 & 50-328/93-53 on 931115-19.No Violations Noted.Major Areas Inspected:Meteorological Monitoring,Control Room Emergency Ventilation,Audits & Secondary Water Chemistry IR 05000327/19930511993-12-13013 December 1993 Partially Withheld Insp Repts 50-327/93-51 & 50-328/93-51 on 931115-19 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Mgt Support,Security Program Plans & Implementing Procedures & Security Program Audit IR 05000327/19930501993-11-24024 November 1993 Insp Repts 50-327/93-50 & 50-328/93-50 on 931011-1106. Violations Noted.Major Areas Inspected:Plant Operations, Plant Maintenance,Plant Surveillance,Evaluation of Licensee self-assessment Capability & LER Closeout IR 05000327/19930421993-11-0909 November 1993 Insp Repts 50-327/93-42 & 50-328/93-42 on 930904-1010. Violations Noted.Major Areas Inspected:Plant Operations, Maint & Surveillance,Evaluation of Licensee self-assessment Capability & Licensee Event Rept Closeout IR 05000327/19930481993-11-0909 November 1993 Insp Repts 50-327/93-48 & 50-328/93-48 on 931006-08. Violation Noted.Major Areas Inspected:Qualifications of Acting Lab Supervisor,Use of Expired Stds in Alcohol breath-analysis Equipment & Testing Lab Procedures 1999-09-27
[Table view] Category:UTILITY
MONTHYEARIR 05000327/19900341990-11-16016 November 1990 Insp Repts 50-327/90-34 & 50-328/90-34 on 901006-1105.One Violation & One Apparent Violation Noted.Major Areas Inspected:Operational Safety Verification Including Control Room Observations & Sys Lineups IR 05000327/19900361990-11-0909 November 1990 Augmented Insp Team Repts 50-327/90-36 & 50-328/90-36 on 901011-19.Insp Included Review of Events That Led to Discovery of Multiple Failures of Main Steam Check Valves on 901008 IR 05000327/19900321990-11-0101 November 1990 Insp Repts 50-327/90-32 & 50-328/90-32 on 900906-1005. Violations Noted.Major Areas Inspected:Operational Safety Verification,Including Control Room Observations,Operations Performance,Sys Lineups & Radiation Protection IR 05000327/19900291990-10-0505 October 1990 Insp Repts 50-327/90-29 & 50-328/90-29 on 900827-31. Violation Noted.Major Areas Inspected:Measurement of Incore Power Distributions,Calibr of Nuclear Instruments, Measurement of Thermal Power & Followup of LERs IR 05000327/19900311990-09-26026 September 1990 Insp Repts 50-327/90-31 & 50-328/90-31 on 900910-14.No Violations or Deviations Noted.Major Areas Inspected: Occupational Exposure During Extended Outages & Licensee Actions to Correct Previously Identified Weaknesses IR 05000327/19900261990-08-30030 August 1990 Insp Repts 50-327/90-26 & 50-328/90-26 on 900706-0805. Violations Noted But Not Cited.Major Areas Inspected:Control Room Observations,Operations Performance,Sys Lineups, Radiation Protection & Safeguards ML20059H0431990-08-21021 August 1990 Insp Repts 50-327/90-23 & 50-328/90-23 on 900625-29.No Violations or Deviations Noted.Weaknesses in Program Implementation Noted.Major Areas Inspected:Plant Program to Maintain Occupational Dose to Workers ALARA IR 05000327/19900211990-07-31031 July 1990 Insp Repts 50-327/90-21 & 50-328/90-21 on 900709-13.No Violations or Deviations Noted.Major Areas Inspected: Observation & Evaluation of Annual Emergency Response Exercise IR 05000327/19900201990-06-29029 June 1990 Insp Repts 50-327/90-20 & 50-328/90-20 on 900506-0605.No Violations or Deviations Noted.Major Areas Inspected: Operational Safety Verification,Including Control Room Observations,Operations Performance & Sys Lineups IR 05000327/19890201989-08-29029 August 1989 Insp Repts 50-327/89-20 & 50-328/89-20 on 890717-20.No Violations or Deviations Noted.Major Areas Inspected:Annual Emergency Exercise,Including Staffing & Response of Emergency Organizations in Control Room & Support Ctrs IR 05000327/19890141989-08-28028 August 1989 Insp Repts 50-327/89-14 & 50-328/89-14 on 890424-28. Violations Noted.Major Areas Inspected:Surveillance & Operational Records & Procedures.Discussions Held W/ Operations,Engineering & Transmissions Personnel IR 05000327/19890191989-08-25025 August 1989 Insp Repts 50-327/89-19 & 50-328/89-19 on 890706-0805. Violations Noted.Major Areas Inspected:Operational Safety Verification,Including Control Room Observations,Operations Performance,Sys Lineups & Radiation Protection IR 05000327/19890181989-08-10010 August 1989 Insp Repts 50-327/89-18 & 50-328/89-18 on 890606-0705. Violations Noted.Major Areas Inspected:Operational Safety Verification,Control Room Observations,Sys Lineups,Radiation Protection,Safeguards,Operations Performance & Housekeeping ML20245L3191989-08-0101 August 1989 Insp Repts 50-327/89-11 & 50-328/89-11 on 890626-30. Violations Noted.Major Areas Inspected:Radiation Protection Program,Follow Up on Previous Inspector Identified Items & IE Info Notices IR 05000327/19890171989-07-28028 July 1989 Partially Withheld Safeguards Insp Repts 50-327/89-17 & 50-328/89-17 on 890522-26 (Ref 10CFR2.790(d) & 73.21)). Violations Noted.Major Areas Inspected:Physical Security Program for Power Reactors & Protected Area Alarms ML20246B6511989-06-26026 June 1989 Insp Repts 50-327/89-15 & 50-328/89-15 on 890506-0605. Violations Noted.Major Areas Inspected:Operational Safety Verification,Operations Performance,Sys Lineups,Radiation Protection,Safeguards & Housekeeping Insps ML20245D4191989-06-14014 June 1989 Insp Repts 50-327/89-16 & 50-328/89-16 on 890508-12. Violation Noted.Major Areas Inspected:Review of Completed Unit 2,Cycle 4 Initial Criticality & Post Refueling Start Up Tests & Evaluation of Thermal Power Measurements for Unit 1 IR 05000327/19890121989-05-24024 May 1989 Insp Repts 50-327/89-12 & 50-328/89-12 on 890406-0505. Violation Noted.Major Areas Inspected:Radiation Protection, Safeguards & Operational Safety Verification,Including Control Room Observations & Operational Performance IR 05000327/19890131989-05-16016 May 1989 Insp Repts 50-327/89-13 & 50-328/89-13 on 890417-21.No Violations or Deviations Noted.Major Areas Inspected: Emergency Preparedness,Including Review of Programmatic Elements & Radiological Emergency Plan & Training IR 05000327/19890101989-05-0404 May 1989 Insp Repts 50-327/89-10 & 50-328/89-10 on 890316-20.No Violations or Deviations Noted.Major Areas Inspected: Containment Integrated Leak Rate Testing,Review of Test Procedures & Evaluation of Test Results ML20246K0751989-05-0303 May 1989 Insp Repts 50-327/89-09 & 50-328/89-09 on 890305-0405. Violations Noted.Major Areas Inspected:Operational Safety Verification,Including Operations Performance,Sys Lineups, Radiation Protection,Safeguards & Housekeeping Insps IR 05000327/19890071989-04-13013 April 1989 Insp Repts 50-327/89-07 & 50-328/89-07 on 890205-0304. Violations Noted.Major Areas Inspected:Operational Safety Verification,Including Operations Performance,Sys Lineups, Radiation Protection,Safeguards & Housekeeping ML20244C3911989-04-0404 April 1989 Insp Repts 50-327/88-50 & 50-328/88-50 on 881212-890126. Violations Noted.Major Areas Inspected:Plant Operations, Surveillance & Sys Outage Control,Corrective Action Program, Maint Activities & Qualified Reviewer Process IR 05000327/19890051989-03-13013 March 1989 Special Team Insp Repts 50-327/89-05 & 50-328/89-05 on 890131-0209.Violations Noted.Major Areas Inspected:Radwaste, Radiological Controls,Corporate QA Audits & Site Chemistry ML20247F3461989-03-13013 March 1989 Special Team Insp Repts 50-327/89-05 & 50-328/89-05 on 890131-0209.Violations Noted.Major Areas Inspected:Radwaste, Radiological Controls,Corporate QA Audits & Site Chemistry IR 05000327/19890061989-03-10010 March 1989 Partially Withheld Insp Repts 50-327/89-06 & 50-328/89-06 on 890123-27 (Ref 10CFR2.790(d) & 73.21).Violation Noted.Major Areas Inspected:Physical Security Program for Reactors, Including Security Mgt,Audit,Barriers,Alarms & Maint IR 05000327/19890021989-03-0909 March 1989 Insp Repts 50-327/89-02 & 50-328/89-02 on 890105-0204.No Violations or Deviations Noted.Major Areas Inspected: Operational Safety Verification Including,Operations Performance,Sys Lineups & Radiation Protection IR 05000327/19890081989-03-0303 March 1989 Insp Repts 50-327/89-08 & 50-328/89-08 on 890213-17. Violations Noted.Major Areas Inspected:Inservice Insp, Including Eddy Current Exam of Unit 2 Steam Generator Tubing,Reviews of NDE Exams Procedures & Exam Verifications IR 05000327/19880601989-03-0101 March 1989 Insp Repts 50-327/88-60 & 50-328/88-60 on 881222-23 & 890222.Major Areas Inspected:Review Licensee Resolution of Differences Between Measured & Predicted Critical Boron Concentrations Observed During Restart Testing IR 05000327/19890041989-02-15015 February 1989 Insp Repts 50-327/89-04 & 50-328/89-04 on 890117-20.No Violations or Deviations Noted.Major Areas Inspected: Licensee Action on Previous Insp Findings,Ie Bulletin 80-11 & Snubber Surveillance Programs IR 05000327/19890031989-02-10010 February 1989 Insp Repts 50-327/89-03 & 50-328/89-03 on 890109-13.No Violations or Deviations Noted.One Unresolved Item Identified.Major Areas Inspected:Inservice Insp & Inservice Testing of Pumps & Valves IR 05000327/19880471988-11-28028 November 1988 Insp Repts 50-327/88-47 & 50-328/88-47 on 881012-19.No Violations Noted.Major Areas Inspected:Operations Performance,Sys Lineups,Radiation Protection & Safeguards & Housekeeping Insps IR 05000327/19880451988-11-22022 November 1988 Insp Repts 50-327/88-45 & 50-328/88-45 on 880920-28 & 27-28. No Violations or Deviations Noted.Major Areas Inspected: Snubber Surveillance Program & Licensee Action on Previous Insp Findings ML20205Q6801988-10-28028 October 1988 Insp Repts 50-327/88-43 & 50-328/88-43 on 880906-09. Violations Noted.Major Areas Inspected:Followup on Previous Insp Finding & 10CFR50.59 Safety Evaluation Program & Implementation Re Plant Site IR 05000327/19880461988-10-27027 October 1988 Insp Repts 50-327/88-46 & 50-328/88-46 on 881005-11. Violations Noted.Major Areas Inspected:Operational Safety Verification,Including Operations Performance,Sys Lineups, Radiation Protection,Safeguards & Housekeeping IR 05000327/19880421988-10-25025 October 1988 Insp Repts 50-327/88-42 & 50-328/88-42 on 880829-0902.No Violations or Deviations Noted.Major Areas Inspected: Operational Staffing,Review Committee Activities,Maint Status & Status of Testing IR 05000327/19880441988-10-24024 October 1988 Insp Repts 50-327/88-44 & 50-328/88-44 on 880913-1005. Violations Noted.Major Areas Inspected:Operational Safety Verification Including Operations Performance,Sys Lineups, Radiation Protection,Safeguards & Housekeeping Insps IR 05000327/19880401988-10-21021 October 1988 Insp Repts 50-327/88-40 & 50-328/88-40 on 880925-1004. Violation Noted.Major Areas Inspected:Extended Control Room Operation & Operational Safety Verification,Including Radiation Protection & Safeguards IR 05000327/19880391988-10-18018 October 1988 Insp Repts 50-327/88-39 & 50-328/88-39 on 880806-0912.No Violations Noted.Major Areas Inspected:Operational Safety Verification,Including Operations Performance,Sys Lineups, Radiation Protection & Safeguards & Housekeeping Insps ML20195C7751988-10-12012 October 1988 Insp Repts 50-327/88-29 & 50-328/88-29 on 880620-0708. Violations Noted.Major Areas inspected:in-plant Review in Mechanical,Electrical,Civil,Structural & Instrumentation Control Disciplines in Order to Verify CS Sys Design Basis IR 05000327/19880411988-09-22022 September 1988 Partially Withheld Insp Repts 50-327/88-41 & 50-328/88-41 on 880822-26 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Security Records, Maint,Locks,Power Supply,Lighting & Compensatory Measures IR 05000327/19880381988-09-15015 September 1988 Insp Repts 50-327/88-38 & 50-328/88-38 on 880725-29.No Violations or Deviations Noted.Major Areas Inspected:Plant Chemistry,Corrosion Control & Pipe Wall Thinning ML20154N5121988-09-15015 September 1988 Insp Repts 50-327/88-36 & 50-328/88-36 on 880712-0805. Violation Noted.Major Areas Inspected:Operational Safety Verification,Including Operations Performance,Sys Lineups, Radiation Protection & Safeguards & Housekeeping Insps ML20154L6431988-09-12012 September 1988 Insp Repts 50-327/88-35 & 50-328/88-35 on 880711-15 & 0822- 23.Violations Noted.Major Areas Inspected:Excessive post-trip Cooldown Condition & Effect on end-of-life Margin ML20153C4721988-08-22022 August 1988 Insp Repts 50-327/88-33 & 50-328/88-33 on 880711-15. Violation Noted.Major Areas Inspected:Emergency Preparedness,Including Review of Listed Progammatic Elements ML20207D7061988-07-27027 July 1988 Insp Repts 50-327/88-27 & 50-328/88-27 on 880501-0530. Violation Noted.Major Areas Inspected:Operational Safety Verification,Review of Previous Insp Findings,Followup of Events & Review of Licensee Identified Items IR 05000327/19880281988-07-25025 July 1988 Insp Repts 50-327/88-28 & 50-328/88-38 on 880505-0602. Violations Noted.Major Areas Inspected:Extended Control Room Observation & Operational Safety Verification,Maint,Review of Previous Insp Findings & Follow Up of Events ML20153C1251988-07-19019 July 1988 Insp Repts 50-327/88-31 & 50-328/88-31 on 880606-10. Violations Noted:Failure to Perform Air Sampling Per Written Procedures.Major Areas Inspected:Training & Qualifications, External & Internal Exposure Controls & Solid Wastes IR 05000327/19880311988-07-19019 July 1988 Revised Insp Repts 50-327/88-31 & 50-328/88-31 on 880606-10. Violation Noted.Major Areas Inspected:Areas of Training & Qualifications,External & Internal Exposures Control,Control of Radioactive Matl & Surveys,Solid Waste & Transportation ML20196L3571988-06-24024 June 1988 Insp Repts 50-327/88-12 & 50-328/88-12 on 880215-19.No Violations or Deviations Noted.Major Areas Inspected:Review of Util Corrective Actions Re Civil Engineering Portion of Calculation Review Program & Review of Piping Analyses 1990-09-26
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARIR 05000327/19990051999-09-27027 September 1999 Insp Repts 50-327/99-05 & 50-328/99-05 on 990718-0828. Violations Noted.Major Areas Inspected:Mitigating Sys ML20210V1621999-08-13013 August 1999 Insp Repts 50-327/99-04 & 50-328/99-04 on 990601-0717.One Potentially Safety Significant Issue Noted.Major Areas Inspected:Licensee Emergency Preparedness IR 05000327/19990031999-06-30030 June 1999 Insp Repts 50-327/99-03 & 50-328/99-03 on 990328-0531.Non- Cited Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Maint & Engineering IR 05000327/19990021999-04-23023 April 1999 Insp Repts 50-327/99-02 & 50-328/99-02 on 990214-0327.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint & Engineering IR 05000327/19990011999-03-15015 March 1999 Insp Repts 50-327/99-01 & 50-328/99-01 on 990103-0213. Violations Noted & Being Treated as non-cited Violations. Major Areas Inspected:Aspects of Licensee Operations,Maint & Engineering IR 05000327/19983021999-03-12012 March 1999 NRC Operator Licensing Exam Repts 50-327/98-302 & 50-328/98-302 (Including Completed & Graded Tests) for Test Administered on 980928-1001 ML20202J5471999-02-0101 February 1999 Notice of Violation from Insp on 981122-990102.Violation Noted:Following Unit 1 Rt on 981109,procedural Requirements of EOP ES0.1 Were Not Properly Implemented,In That RCS Temperatures Were Not Monitored & Steam Not Dumped IR 05000327/19980111999-02-0101 February 1999 Insp Repts 50-327/98-11 & 50-328/98-11 on 981122-990102. Violations Noted.Major Areas Inspected:Licensee Operations, Maint & Engineering IR 05000327/19980101998-12-0707 December 1998 Insp Repts 50-327/98-10 & 50-328/98-10 on 981011-1121.No Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000327/19980141998-12-0404 December 1998 Insp Repts 50-327/98-14 & 50-328/98-14 on 981102-06.No Violations Noted.Major Areas Inspected:Observation & Evaluation of Biennial Emergency Preparedness Exercise for Sequoyah Nuclear Plan ML20196D6081998-11-24024 November 1998 Notice of Violation from Insp on 980914-1016.Violation Noted:As of 980916,requirements of 0-MI-MXX-061-001 Not Implemented IR 05000327/19980131998-11-24024 November 1998 Insp Repts 50-327/98-13 & 50-328/98-13 on 980914-1016. Violations Noted.Major Areas Inspected:Aspects of Licensee maint,testing,engineering,self-assessment & Problem Evaluations of Licensee Ice Condenser Sys ML20195G5521998-11-0909 November 1998 Notice of Violation from Insp on 980830-1010.Violation Noted:Licensee Failed to Assure That All Testing Required to Demonstrate That Safety Related Circuit Breakers Would Perform Satisfactorily in Svc IR 05000327/19980091998-11-0909 November 1998 Insp Repts 50-327/98-09 & 50-328/98-09 on 980830-1010. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering Plant Support & Effectiveness of Licensee Controls in Identifying,Resolving & Preventing Problems IR 05000327/19980081998-09-18018 September 1998 Insp Repts 50-327/98-08 & 50-328/98-08 on 980719-0829.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support,Licensee Conducted Radiological Emergency Plan Drill IR 05000327/19980071998-08-0404 August 1998 Insp Repts 50-327/98-07 & 50-328/98-07 on 980607-0718. Violations Noted.Major Areas Inspected:Aspects of Licensee Operation,Maint,Engineering,Plant Support & Effectiveness of Licensee Controls in Identifying & Preventing Problems ML20237B1851998-08-0404 August 1998 Notice of Violation from Insp on 980606-0718.Violations Noted:On or Before 971103,conditions Adverse to Qualify Were Not Promptly Identified & Corrected,In That Licensee Failed to Correct &/Or Initiate Problem Evaluation Rept ML20236J6631998-06-26026 June 1998 Insp Repts 50-327/98-06 & 50-328/98-06 on 980426-0606. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support ML20236J6591998-06-26026 June 1998 Notice of Violation from Insp on 980426-0606.Violation Noted:Inservice Testing of Valves Not in Accordance with Section XI of ASME Boiler & Pressure Vessel Code & Applicable Addenda as Required by 10CFR50.55a IR 05000327/19983001998-06-25025 June 1998 NRC Operator Licensing Exam Repts 50-327/98-300 & 50-328/98-300 (Including Completed & Graded Tests) for Tests Administered on 980601-02 IR 05000327/19980051998-06-12012 June 1998 Insp Repts 50-327/98-05 & 50-328/98-05 on 980504-08.No Violations Noted.Major Areas Inspected:Maint Procedure.Insp Team Comprised Region II & Headquarters Personnel.Switchgear & Surrounding Areas Found in Good Matl Condition ML20247L5781998-05-15015 May 1998 Notice of Violation from Insp on 980315-0425.Violation Noted:Licensee Failed to Perform Surveillance Requirement 4.8.1.1.1.a,within 1 H & at Least Once Per 8 H Thereafter IR 05000327/19980041998-05-15015 May 1998 Insp Repts 50-327/98-04 & 50-328/98-04 on 980315-0425. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20216H7841998-04-10010 April 1998 Insp Repts 50-327/98-03 & 50-328/98-03 on 980201-0314. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20216H7701998-04-10010 April 1998 Notice of Violation from Insp on 980201-0314.Violation Noted:License Failed to Rept an Adverse Condition on Work Request/Work Order &/Or Problem Evaluation Rept IR 05000327/19980991998-04-0101 April 1998 SALP Repts 50-327/98-99 & 50-328/98-99 for Period 960728- 980221 ML20217K3751998-03-30030 March 1998 Notice of Violation from Insp on 980126-0213.Violation Noted:On Listed Dates,Licensee Made Changes to Facility as Described in FSAR W/O Adequate Written SE Which Provides Bases for Determination That Changes Did Not Involve USQ ML20217K3801998-03-30030 March 1998 Insp Repts 50-327/98-01 & 50-328/98-01 on 980126-0213.No Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000327/19980021998-03-0505 March 1998 Insp Repts 50-327/98-02 & 50-328/98-02 on 980202-06.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations & Maint.Review of Initial & Requalification Training Programs Were Also Conducted ML20203J5411998-02-19019 February 1998 Notice of Violation from Insp on 971231-980131.Violation Noted:On 980126 Individuals Failed to Monitor Themselves in Whole Body Contamination Monitor or W/Hand & Foot Frisk Monitor ML20203J5541998-02-19019 February 1998 Insp Repts 50-327/97-18 & 50-328/97-18 on 971221-980131. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering,Plant Support & Effectiveness of Licensee Controls in Identifying & Resolving Problems ML20216D8431998-02-0606 February 1998 EN-97-109A:on 980206,informs of Withdrawal of Proposed Civil Penalty of $55,000 Issued to Licensee.Credit for Identification Appropriate to Recognize Diligence of TVA Training Instructor Who Discovered Vital Battery Problem IR 05000327/19970171998-01-16016 January 1998 Insp Repts 50-327/97-17 & 50-328/97-17 on 971109-1220.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering,Plant Support & Effectiveness of Licensee Controls in Identifying,Resolving & Preventing Problems IR 05000327/19970141997-12-0808 December 1997 Insp Repts 50-327/97-14 & 50-328/97-14 on 970928-1108.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering,Plant Support,Effectiveness of License Controls in Identifying,Resolving & Preventing Problems ML20197F5541997-12-0808 December 1997 Notice of Violation from Insp on 970725-0704 & Proposed Imposition of Civil Penalty in Amount of $55,000.Violation Noted:Sro Failed to Implement Step 8.4.8 of Soi 0-S0-250-1. Predecisional EC Agenda & Documentation Encl IR 05000327/19970161997-12-0505 December 1997 Insp Repts 50-327/97-16 & 50-328/97-16 on 971103-06.No Violations Noted.Major Areas Inspected:Evaluation of 971017 Wire Damage Event at Electrical Penetration 22 ML20197F6971997-12-0303 December 1997 EN-97-109:on 971208,notice of Proposed Imposition of Civil Penalty in Amount of $55,000 Issued to Licensee.Action Based on Severity Level III Problem Re Failure to Maintain Direct Current Vital Battery Channel Energized & Operable ML20199H1451997-11-0606 November 1997 Exam Repts 50-327/97-300 & 50-328/97-300 on 970919-1007. Exam Results:Four Out of Seven Candidates Passed Exam.One Candidate Was Marginal Performer IR 05000327/19970121997-10-24024 October 1997 Insp Repts 50-327/97-12 & 50-328/97-12 on 970824-0927.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support & Operator Requalification Program IR 05000327/19970151997-10-23023 October 1997 Insp Repts 50-327/97-15 & 50-328/97-15 on 970922-29.No Violations Noted.Major Areas Inspected:Emergency Preparedness PNO-II-97-055, on 971006,contaminated Person Transported from Sequoyah Nuclear Plant to Offsite Medical Facility,Following Apparent Heart Attack.Victim Pronounced Dead at Hosp,Due to Apparent Heart Attack.Licensee Responded to Media Inquirie1997-10-0606 October 1997 PNO-II-97-055:on 971006,contaminated Person Transported from Sequoyah Nuclear Plant to Offsite Medical Facility,Following Apparent Heart Attack.Victim Pronounced Dead at Hosp,Due to Apparent Heart Attack.Licensee Responded to Media Inquirie ML20211E2531997-09-22022 September 1997 Notice of Violation from Insp on 970706-0823.Violation Noted:On 970714,containment Isolation Valve 1-FCV-31C-229 Failed to Exhibit Required Change of Obturator Position & Was Not Repaired or Replaced & Data Not Analyzed IR 05000327/19970081997-09-22022 September 1997 Insp Repts 50-327/97-08 & 50-328/97-08 on 970706-0823. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering,Plant Support & Effectiveness of Licensee Controls in Identifying,Resolving & Preventing Problems IR 05000327/19970091997-09-15015 September 1997 Insp Repts 50-327/97-09 & 50-328/97-09 on 970804-08.No Violations Noted.Major Areas Inspected:Operations,Maint & Engineering Re Effectiveness of Licensee Controls in Identifying,Resolving & Preventing Problems ML20198H7911997-09-11011 September 1997 Insp Repts 50-327/97-13 & 50-328/97-13 on 970725-0904. Violations Noted.Major Areas Inspected:Insp Scope,Event Synopsis & Observations & Findings ML20141H9581997-07-28028 July 1997 Insp Repts 50-327/97-06 & 50-328/97-06 on 970525-0705. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20141H9531997-07-28028 July 1997 Notice of Violation from Insp on 970525-0705.Violation Noted:Licensee Failed to Implement Prompt Corrective Actions to Resolve Condition Adverse to Quality ML20149L5671997-07-24024 July 1997 Notice of Violation from Insp on 970623-27.Violation Noted: on 960627,licensee Had Loss of Security Electronic Equipment & Failed to Post Officers in Position to Provide Surveillance of Entire Protected Area Perimeter IR 05000327/19970071997-07-24024 July 1997 Insp Repts 50-327/97-07 & 50-328/97-07 on 970623-27. Violations Noted.Major Areas Inspected:Aspects of Licensee Plant Support ML20149G8681997-07-10010 July 1997 Notice of Violation from Insp on 970324-0522.Violation Noted:Licensee Failed to Esatblish Measures to Assure That Significant Condition Adverse to Quality Was Promptly Identified & Corrected & C/A Taken to Preclude Repetition 1999-09-27
[Table view] |
See also: IR 05000327/1985026
Text
. - . . . . .-. . -.
e -
UNITED STATES
4 #p>* MGoq'o NUCLEAR REGULATORY COMMISSION
[ -
'n REGION ll
5 101 MARIETTA STREET N.W.
- *" *j ATLANTA, GEORGI A 3o323
,
\...../
i Report Nos.: 50-327/85-26 and 50-328/85-26
Licensee: Tennessee Valley Authority
6N11 B Missionary Ridge Place
Chattanooga, TN 37402
Docket Nos.: 50-327 and 50-328
'
License Nos.: DPR-77 and DPR-79
Facility Name: Sequoyah.1 and 2
Inspection Conducted: July 6 - August 5, 1985
Inspectors: 6 ./) . - d w h J, 9/4/85
q K.M.Jenis66,SenfofResidentInspector Dat( Signed
G 0. n v: c/C/85 t
t
. J. Watson,LResidep ~Insp c~ tor DatV Sfgned
Accompanying Insp ct r: J. W. York, Senior Resident Inspector, Bellefonte
Approve by: h7 A 7
S. P. $1se, Section Chief Date S'igned
Division of Reactor Projects
SUMMARY
,
Scope: This routine, announced inspection involved 256 resident inspector-hours
'
onsite in the areas of operational safety verification including operations
performance, system lineups, radiation protection, security and housekeeping
inspections; surveillance and maintenance observations; review of previous
inspection findings; followup of events; review of licensee identified items and
. review of licensee response to NRC IE Information Notice 84-31.
Results: In the areas inspected, two violations were identified (Failure to
follow procedures for whole body frisking after exit from a contaminated zone
(paragraph 5); and Failure to follow procedures to document and correct an
Individual Rod Position. Indication module deficiency (paragraph-5)).
,
8509180072 850906
i PDR ADOCK 05000327
G PDR
-
. - - . . . - . - - - - - -
. , - . , - . . . - - , - . - , - , , - . - , , . .
'
.
REPORT DETAILS
1. Persons Contacted
Licensee Employees
- H. L. Abercrombie, Site Director
- P. R. Wallacc, Plant Manager i
- L. M. Nobles, Operations and Engineering Superintendent
- B. M. Patterson, Maintenance Supervisor
M. R. Harding, Engineering Group Supervisor
- J. M. Anthony, Operations Group Supervisor
D. C. Craven, Quality Assurance Supervisor ,
D. E. Crawley, Health Physics Supervisor '
- J. L. Hamilton, Quality Engineering Supervisor
- G. B. Kirk, Compliance Supervisor ,
- D. H. Tullis, Mechanical Maintenance Group Supervisor ,
- D. L. Love, Mechanical Maintenance Engineering Section Supervisor
- J. T. Crittenden, Public Safety Supervisor
f
Other licensee employees contacted included technicians, operators, shift
engineers, security force members, engineers, and maintenance personnel.
2. Exit Interview
1
The inspection scope and findings were summarized with the Plant Manager and
members of his staff on August 7, 1985. Violations described in paragraphs
5.a. and 5.d. were discussed. The licensee acknowledged the inspection
findings. The licensee did not identify as proprietary any material
reviewed by the inspectors during this inspection. During the reporting <
period, frequent discussions were held with the Site Director, Plant Manager
and his assistants concerning inspection findings. At no time during the
inspection was written material provided to the licensee by the inspector.
3. Licensee Action on Previous Enforcement Matters (92702)
(Closed) Violation 328/83-29-01. The licensee's response of February 8,
1984, was reviewed and the indicated corrective actinns were audited. The
licensee took administrative disciplinary action in this case which involved
an operator who failed to follow established system alignment procedures.
System Operating Instruction S01-14.3, Condensate Demineralizer Waste
Disposal, was amended to include independent verification. Plant personnel
have also received additional training in. procedural compliance. The
licensee's corrective actions are considered complete.
t
.-. .. .
-
.
2
(Closed) Violation 328/83-29-03. The licensee's response of February 8,
1984, was reviewed and the indicated corrective actions were audited. The
licensee took administrative disciplinary action in this case which involved
an operator who failed to follow established system operating procedures.
Also, plant personnel have received additional training in procedural
compliance. The licensee's corrective actions are considered complete.
(Closed) Violation 327, 328/84-25-02. The licensee response of November 23,
1984, was reviewed and the indicated corrective action was audited. The
licensee submitted a revision to LER 84055 describing the events which led
to the inadequate LER and providing additional information on the breaches
of the ABSCE. LER 84055, Revision 1, was closed in Inspection Report 327,
328/85-16. In addition, the inspector noted an improvement in the quality
of LER submittals. The licensee's corrective actions are considered
complete.
J
(Closed) Violation 327, 328/84-29-01. The licensee's response of
January 18, 1984, was reviewed and the indicated corrective action was
audited. The licensee revised Surveillance Instruction SI-256.2, Inspection
of Molded Case and Lower Voltage Circuit Breakers, to provide alternate
power to breaker 213 en the 125 volt Vital Battery Board III when the
4
breaker is being tested and to include a signcff to ensure that the alter-
nate power is provided to the fuse column.
(Closed) Violation 327, 328/84-35-01. The licensee's response of
January 21, 1985, was reviewed and the indicated corrective action was
audited. The licensee reviewed System Operating Instruction SOI-63.1 and
verified that the procedure had been revised to include the two missing
level transmitter root valves for the cold leg accumulators. The licensee's
corrective actions are considered complete.
4. Unresolved Items
Unresolved items are matters about which more information is required to
determine whether they are acceptable or may involve violations or devia-
tions. One unresolved item identified during this inspection is discussed
in paragraph 8.
5. 0perational Safety Verification (71707)
a. Plant Tours
The inspectors observed control room operations, reviewed applicable
logs, conducted discussions with control room operators, observed shift
turnovers, and confirmed operability of instrumentation. The
inspectors verified the operability of selected emergency systems,
reviewed tagout records, verified compliance with Technical Specifica-
tion (TS) Limiting Conditions for Operations (LCO) and verified return
to service of affected components. The inspector verified that
maintenance work orders had been submitted as required and that
followup activities and prioritization of work was accomplished by the
- - -
-
.
3
licensee. Tours of the diesel generator, auxiliary, turbine buildings
were conducted to observe plant equipment conditions, including
potential fire hazards, fluid leaks, and excessive vibrations and plant
housekeeping / cleanliness conditions.
During the performance of a routine Unit 2 Control Room tour the
inspectors noticed a wedge of paper pressed between two Individual Rod
Position Indication (IRPI) modules on the main control panel 2-M-4.
This same wedge of paper was' still in the panel three days later on a
succeeding inspection tour. When the assigned Reactor Operator was
questioned about the foreign object, he stated that the paper was to
keep the module from vibrating. Vibrations cause the rear contacts on
the module to become loose, resulting in a loss of indication and an
inoperable module. No Maintenance Request (MR) had been written to
repair the module, and there was no Temporary Alteration Control Form
(TACF) prescribing the use of the paper wedge. Administrative
Instruction 12 requires that personnel formally identify deficiencies
and that such deficiencies be promptly identified and corrected.
Failure to follow procedures .foi ' entification and correction of the
vibration deficiency affecting o,mrability of the subject IRPI is a
violation (328/85-26-09).
The inspectors walked down accessible portions of the following
safety-related systems on Unit I and Unit 2 to verify operability and
proper valve alignment:
Safety Injection System (U$its 1 and 2)
- Turbine Driven Auxiliary Feedwater System (Units 1 and 2)
Upper Head Injection System (Units 1 and 2)
Diesel Generators (Units 1 and 2)
Emergency Gas Treatment System (Units 1 and 2)
On July 17, 1985, during a walkdown of diesel . generator 1A1, the
inspectors observed an air leak in pressure reducing valve
0-FCV-82-172A. The licensee wrote MR A-537220 to correct the
deficiency. It was determined that the body of the valve was cracked.
A new valve has been ordered and the valve will be replaced during the
first surveillance (i.e. , the next time the diesel will be _out of
service) after the valve is received. The licensee stated that the DG
was operable due to the redundant air start system for the engine. The
DG was started successfully on August 7, 1985. Repair of this valve is
identified as Inspector Followup Item (327, 328/85-26-01).
b. Verification of Ice Condenser Door Operability
The inspector's review of ice condenser door operability is documented
in Inspector Report 327, 328/85-23. During this inspection period, the
inspector discussed the methods for independent verification of removal
of door blocks from the lower ice condenser doors with the licensee.
The licensee stated that the lower ice condenser doors would be
numbered and that a double visual verification of the removal of the
i
-
.
4
door blocks would be conducted and double signoffs recorded for each
door. This is identified as Inspector Followup Item (327, 328/
85-26-02) until licensee actions are completed.
c. Security
During the course of the inspection, observations relative to protected
and vital area security were made, including access controls, boundary
integrity, search, escort, and badging. Two security concerns were
identified during the inspection period which will be reviewed by NRC
Region II security inspectors for potential violations. These concerns
involved movement of materials into the protected area and the
visibility of the protected area boundary.
d. Radiation Protection
The inspectors observed Health Physics (HP) practices and verified
implementation of radiation protection control. On a regular basis,
radiation work permits (RWPs) were reviewed and specific work
activities were monitored to assure the activities were being conducted
in accordance with applicable RWPs. Selected radiation protection
instruments were verified operable and calibration frequencies were
reviewed.
On July 16, 1985, after observing a functional test on the B train
waste gas compressor, the inspector exited the contaminated zone and
went to the personnel frisking station on EL690. After frisking, the
inspector noted that two individuals who had also exited the
contaminated zone had not arrived at the frisking station. The
inspector found the individuals outside the regulated area. The
inspector interviewed the two individuals and determined that they had
not conducted a whole body frisk when exiting the contaminated zone.
The individuals had used a hand and foot monitor at the exit of the-
regulated zone. The inspector discussed the incident with Health
Physics. The two individuals were recalled, a whole body frisk
performed, and surveys conducted of the areas the individuals had
entered after leaving the contaminated zone. The hand and foot monitor
and whole body and area surveys performed by the licensee after the
incident indicated that the individuals were not contaminated. Radio-
logical Control Instruction RCI-1, Radiological Hygience Control, which
was established to implement the requirements of Technical Specifica-
tion 6.11, states that individuals exiting a contaminated zone are
required to perform a whole body frisk to prevent the spread of
contamination to other areas. RCI-14, Radiation Work Permit (RWP)
Program, states that it is the responsibility of each employee to
adhere to the requirements of RWPs and RWP Timesheets. RWP 02-0-85663,
which was issued to control access to the waste gas compressor room on
July 16, 1985, required employees to perform a whole body frisk upon
exit from the contaminated room. The failure to perform a whole body
frisk is a violation (327, 328/85-26-03).
-
.
5
On August 5, 1985, during a routine tour of the Auxiliary Building, the
inspector observed several yellow poly bags on an Instrument Mainte-
nance Section cart which were labeled only with the sections's name and
telephone number. The material was unattended in a remote location and
not marked with survey data or radiation warning tape. The inspector
requested Health Physics (HP) to survey the bags. The inspector
discussed the observation with the licensee. The licensee stated that
the bags contained instruments which had been used inside a contami-
nated zone during the morning and were to be used in another
contaminated zone during the afternoon. The technicians using the
instruments had left the regulated area for lunch. Although the bags
were unattended and not marked, the licensee felt that the technicians
were cognizant of the location and content of the bags and were
controlling the material properly. The inspector discussed the
observation with the NRC Region II office and determined that the
procedure was act.aptable in cases where work is still in progress, the
articles are contained in yellow poly bags with identification of the
responsible section on the bag, and licensee employees have been
trained to recognize that material in yellow poly bags are potentially
contaminated. Since the procedure which controls the movement of
radioactive material inside the regulated area, RCI-1, was not clear in
how this situation should be handled, the licensee stated that the
procedure would be revised to address these requirements. The licensee
was cited previously in Inspection Report 327, 328/85-20 for not
labeling a yellow poly bag containing contaminated material which had
been left unattended in the Auxiliary Building on May 22, 1985.
Corrective actions for this previous violation are still under review.
6. Engineered Safety Features Walkdown (71710)
The inspector verified operability of the centrifugal charging pump flowpath
through the boron injection tank on Units 1 and 2 by performing a complete
walkdown of the accessible portions of the systems. The following specifics
were reviewed and/or observed as appropriate:
a. that the licensee's system lineup procedures matched plant drawings and
the as-built configuration;
b. that equipment conditions were satisfactory and items that might
degrade performance were identified and evaluated (e.g. , hangers and
supports were operable, housekeeping, etc., was adequate);
c. with assistance from licensee personnel, the interior of the breakers
and electrical or instrumentation cabinets were inspected for debris,
loose material, jumpers, evidence of rodents, etc.;
d. that instrumentation was properly valved in and functioning and cali-
bration dates were appropriate;
e. that valves were in proper position, breaker alignment was correct,
power was available, and valves were locked as required; and
- - . -__ ,
-
.
6
f. local and remote instrumentation was compared and remote instrumenta-
tion was functional.
No violations or deviations were identified.
7. Monthly Surveillance Observation (61726)
The inspectors observed Technical Specification (TS) required surveillance
testing and verified that testing was performed in accordance with adequate
procedures; that test instrumentation was calibrated; that Limiting
Conditions for Operation were met; that test results met acceptance criteria
requirements and were reviewed by personnel other that the individual direc-
ting the test; that deficiencies identified, as appropriate, and that any
deficiencies identified during the testing were properly reviewed and
resolved by management personnel; and that system restoration was adequate.
For complete tests, the inspector verified that testing frequencies were met
and tests were performed by qualified individuals.
The inspector witnessed / reviewed portions of the following surveillance test
activities:
SI-7, Electrical Power System: Diesel Generators
SI-64, Boric Acid Flow Paths - Valve Position Verification
SI-281, Functional Tests of Radiation Effluent Monitors with Automatic
Actuations (Quarterly)
ST -'5, Channel Calibrations for Radiation Monitoring Systems
No violatict.s or deviations were identified in this area.
8. Monthly Maintenance Observations (62703)
a. Station maintenance activities of safety-related systems and components
were observed / reviewed to ascertain that they were conducted in
accordance with approved procedures, regulatory guides, industry codes
and standards, and in conformance with TS.
The following items were considered during this review: LCOs were met
while components or systems were removed from service; redundant
components were operable; approvals were obtained prior to initiating
the work; activities were accomplished using approved procedures and
were inspected as applicable; procedures used were adequate to control
the activity; troubleshooting activities were controlled and the repair
record accurately reflected what took place; functional testing and/or
calibrations were performed prior to returning components or systems to
service; quality control records were maintained; activities were
accomplished by qualified personnel; parts and materials used were
properly certified; radiological controls were implemented; QC hold
points were established where required and were observed; fire
-
.
7
prevention controls were implemented; outside contractor force
activities were controlled in accordance with the approved Quality
Assurance (QA) program; and housekeeping was actively pursued.
b. Corrective maintenance was reviewed on containment isolation valve
2-67-580D, Essential Raw Cooling Water supply to upper containment
cooler 20. The following documents were reviewed:
Maintenance Requests: A-291918 A-024413
A-533609 A-112021
A-128336 A-151118
A-024411 A-024414
A-024415
Maintenance Instructions: 6.20, Configuration Control During
Maintenance Activities
11.4, Maintenance of CSSC Valves
6.21, Repairs and <: placements of
ASME Section XI Components
6.15, General Procedure, Tightening
bolts
Temporary Alteration Control Forms: 2-85-2012-67, 1-85-5007-67
Surveillance Instruction: SI-158.1, Containment Isolation
Valve Leak Rate Test
Isolation check valves 580A through 0_ are scheduled for replacement
during the next outage period. These valves normally allow ERCW flow
through the upper compartment air cooler and become crud traps as a
result of the low flow rates and the raw condition of the ERCW. Review
of MR-A151118 indicated that a waxy substance had been found during
maintenance on the disc of valve 2-67-580D. After interviews with
those technicians that performed the disc replacement maintenance on
valve 2-67-5800, it appeared that no foreigr. material was placed into
the valve. Several tests were conducted in order to get the valve to
seat correctly and to pass the leak test. This brings the repro-
ducibility of the test into question. In addition, post modification
test data was not taken and treated as a Quality Record for those tests
that failed leak testing. The licensee is committed to ANSI standard
18.7-1976, which requires that' post maintenance test failures be
treated as quality records. Such records provide maintenance history
data for trending and planning purposes. Tests that are intended only
as troubleshooting diagnostic devices and on which operability of the
valve would not be based appear not to require retention. Because of
the iterative nature of lapping valve internals, the status of the
failed tests is unclear as a quality record. The valves were turned
over to a separate group (Engineering Test) for test evaluation four
times. During interviews with the technicians that performed the
. - - . - , - - - - - -
-
.
,
8
maintenance on 2-67-580D, the inspector also learned that its internal
flapper arm was out of round, but not replaced due to lack of parts.
This valve is scheduled to be retested in October 1985 and the results
will be evaluated by the inspector. This is an Unresolved Item (327,
328/85-26-04) until the inspector further evaluates licensee mainte-
nance controls and retention of test records associated with this and
other maintenance.
c. On July 24, 1985, the inspector observed a post maintenance functional
test on the B train waste gas compressor. The following documents were
reviewed:
Maintenance Request (MR) A526712
Hold Order 993
Maintenance Instruction MI-8.20
The compressor was identified on the maintenance request as CSSC
. equipment. The licensee stated that the equipment was QA controlled
but was not safety-related. Maintenance Instruction MI-8.20 provided
detailed steps on performance of the maintenance; however, the
procedure only stated that a functional test was to be performed after
the maintenance. The procedure did not provide any criteria for the
test. This concern was discussed with the licensee. The licensee
stated that functional test criteria would be included in tests for
CSSC equipment that is not safety-related. The licensee is also
examining assignment of responsibility for functional tests to assure
appropriate test control. This is identified as Inspector Followup
Item (327, 328/85-26-05). During the system lineup, the inspector
observed an Auxiliary Unit Operator (AU0) misalign several root valves.
The AU0 later corrected the misaligned valves prior to completion of
the test. The licensee stated that the AVO has received additional
training in the requirements for system alignment. The licensee is
evaluating the need for control of root valves on System Operating
Instructions. The licensee presently controls the position of root
valves by Hold Orders and with Instrument Maintenance procedures. This
is identified as Inspector Followup Item (327, 328/85-26-06).
9. Licensee Event Report (LER) Followup (92700)
The following LERs were reviewed and closed. The inspector verified that:
reporting requirements had been met; causes had been identified; corrective-
actions appeared appropriate; generic applicability had been considered; the
LER forms were completed; the licensee had reviewed the event; no unreviewed
safety questions were involved; and violations of regulations or Technical
Specification conditions had been identified.
a. LERs Unit 1
'
327/83012 Feedwater Flow Channel Declared Inoperable
, 327/83019 Rod Position Indicator Declared Inoperable
.. __ _ _ _ _ . _ _ __
f
-
.
1
l
9
327/83021 Failure of Heat Tracing on BIT
'
327/83025 Inoperable Flow Rate Monitor for Shield Building
Exhaust
327/83026 Failure of ERCW Valve
>
- 327/83056 Inoperable Upper Containment Personnel Inner Airlock
- Door
.
t
327/83065 Inoperable Train of EGTS
327/83070 Diesel Generator Declared Inoperable
i
327/83080 Inoperable Rod Position Indicator
327/83110 Failure of EGTS Cooldown Valves
~
'
327/83137 Diesel Generator 28-B Inoperable
. 327/83180 Thermal Overload Devices Failed to Trip Check
327/84013 Reactor Trip on Low-Low Steam Generator Level
! 327/84018 Fire Protection Deluge Valve Isolated
327/85008 Failure to Meet Fire Watch Requirements
i 327/85010 Containment Ventilation Isolation
327/85011 Failure to Meet Fire Watch Requirements
,
327/85012 Failure to Meet Fire Watch Requirements
t
i 327/85013 Failure to Meet Fire Watch Requirements
' -
327/85015 Failure to Meet Fire Watch Requirements
327/85017 Inadvertent Auxiliary Building Isolations
,
327/85026 Inadvertent Feedwater Isolation
b. LERs Unit 2
4
328/83004 RWST Low Boron Concentration
- and Rev. 1
328/83051 BIT Valve Inoperable
i 328/83059 Rod Position Indication Inoperable
i
i
!-
-. , . ,_ . - - . _ __ _ _ _ - --- - _ _ _ _ _ _ - _ _ - . _ ~ . _ - . . . . _ . _._,
- - . . . . . .. .
.
-
10
328/83068 RWST Low Water Level
328/83081' Upper Containment Airlock Door Inoperable
J
328/83082 RHR Remote Shutdown Channel Inoperable
4
328/83093 Inoperable Flow Rate Monitor
328/83121 Failure of Lower Containment Airlock to Meet Leakage
Criteria
328/83124 Inoperable Con' denser Vacuum Exhaust Flow Rate Monitor
328/83131 Inoperable Condenser Vacuum Exhaust Flow Rate Monitor
328/83153 Containment Airlock Door Not Fully Closed
328/83161 Rod Bottom Light Bistable Inoperable
l 328/83163 Inoperable Rod Position Indicator
328/84003 Inadvertent Containment Building Ventilation Isolations
328/85005 Debris Inside Containment
c. Followup on LER 328/85001 - Unit 2 Reactor Trip on January 14, 1985
,
Surveillance Instruction (SI-80), Power Range Neutron Flux Channel
Calibration and Functional Test, was conducted on Unit 2 Nuclear
Instrument Power Range Channel N-41. SI-80 referenced Instrument
.
'
Maintenance Instruction (IMI-92-PRM-CAL), NIS Power Range, as the
required calibration procedure. Step 5.2.1.6 of IMI-92-PRM-CAL
required that the instrument power fuses be removed and independently
verified. When the instrument power fuses are removed from a Power
Range (PR) Nuclear Instrument (NI) drawer, the high voltage supply to
that drawer is removed and a negative rate flux trip bistable is
activated. The negative rate flux trip bistable does not automatically
reset when the instrument power fuses are replaced and must be manually
'
reset. If two separate NI PR negative rate flux trip bistables are
activated at the same time, a reactor trip results.
A Senior Instrument Maintenance (IM) technician removed the instrument
power fuses from PR NI N-42 in error, replaced the fuses, but did not
reset the reset the channel. When the IM technician subsequently
deenergized PR NI drawer NI-41, by removing the instrument power fuses,
,
the corresponding negative rate was activated. This satisfied a
] two-out-of-four reactor protection system logic, resulting in a Unit 2
i reactor trip from 30's power. The removal of the instrument power fuses
, was determined to be a personnel error by the licensee. The inspectors
- verified this through interviews with personnel involved and a review
i of the licensee's IM training and qualification system. However,
. __ _. __
_ __ __ _ _ _,
_
. -
11
sev-:11 actions taken by the technician after removal of the fuses are
examples of a failure to follow procedure. These actions are explained
- below.
Following the removal of the PR NI drawer N-42 instrument power fuses,
the IM technician failed to follow procedures in two instances. First,
he attempted to place PR NI N-42 back in service by replacing its
instrument power fuses. The appropriate section of IMI-92-PRM-CAL
(Section 7) was not implemented to ensure that N-42 was correctly
returned to service. Second, after the IM technician had returned PR
NI drawer N-42 to what he assumed to be an operable condition, he
commenced surveillance activities on PR NI N-41 without reporting to
the RO or SRO that he had not complied with an assigned procedure and
had affected safety-related equipment not authorized for su,rveillance
activities.
Administrative Instruction AI-12, Adverse Conditions and Corrective
Actions, states that plant personnel shall report any suspected
abnormal plant condition adverse to quality in the performance of their
regular work duties. A failure to follow procedure is defined in
section 4.0 of AI-12 as a condition adverse to quality. The inspector
is not satisfied that licensee personnel clearly understand their -
i responsibility to report to the shift operating staff any unintended
affects on safety-related equipment during planned activities. This
issue will be reviewed as Inspector Followup Item (327, 328/85-26-07).
The LER is closed.
10. Event Followup (93702, 62703, 61726)
a. Unit 1 Reactor Trip Due to Loss of Main Feedwater Pump Turbine (MFPT)
Oil Pump
On July 19, 1985, Unit I tripped from 100 percent power on low-low
steam generator level. The licensee was utilizing normal procedures to
search for a ground on a turbine unit board. In this process, 480V
Unit Board 1B was switched from the normal power supply to an alternate
supply. The operator closed the alternate supply breaker to the board,
but the breaker did not close the breaker completely. He then
deenergized the normal supply. He immediately noted that the MFPT oil
pump light on the board went out and jerked up on the alternate supply
breaker completely closing it; however, the oil pump tripped.
A backup oil pump started automatically on the trip signal; however,
the momentary drop in oil pressure caused partial completion of. logic
associated with the MFPT oil pressure switch. This logic includes
closing of the train associated MFPT stop valves, a main turbine
runback, and start of the motor driven (MDAFWP) and turbine driven
(TDAFWP) auxiliary feedwater pumps among others. The logic was
completed for the closing of the stop valves resulting in coasting down
of the MFPT; however, the turbine runback logic was not completed and
steam generator levels started to decrease. The MDAFWPs started, and
-. . .-. . - - .
. _ _ _ .. . _ _ . .
.
12 -
i
the TDAFWP did not. The operators immediately put the control rods in
auto and attempted to manually runback the main turbine. This was
unsuccessful, and the reactor tripped on low-low stcam generator level.
All reactor protection system functions reacted normally on the reactor
trip including start of the TDAFWP.
The logic associated with the MFPT pressure switch is not a reactor
protection or engineered safety feature signal. The purpose of the
switch is to provide anticipatory features, such as turbine runback,
for events which could lead to low-low steam generator reactor trips. -
The inspector reviewed the logic with a Senior Reactor Operator and
discussed the failure of the logic circuit to completely energize with
the licensee. This problem was attributed to the fast operation of the
pressure switch resulting in only a momentary contact in the logic
circuit. The mechanical contacts eif.her did not have time to makeup or
the seal-in circuit was not energized.
!
.The licensee attempted to duplicate the initiating conditions through
.
testing to ascertain if any problems existed within the logic
1
circuitry; however, the condition could not be duplicated. This
testing and performance of Surveillance Instruction SI-110.1, TDAFWP
and Valve Automatic Actuation, resulted in completion of the full
logic. The licensee adjusted the pressure switch which starts the
backup oil pump to a higher setting to preclude a significant drop in
oil pressure on trip of one of the oil pumps. This should prevent a
similar event.
No violations or deviations were identified.
b. Unit 2 Notification of Unusual Event Due to Excessive Reactor Coolant
System (RCS) Leakage
On July 29, 1985, operators noted a decrease in volume control tank
level. Subsequently, a high radiation alarm on the Auxiliary Building
Vent particulate monitor caused an Auxiliary Building isolation. The
operators followed the requirements of Abnormal Operating Instruction
AOI-31, Abnormal Release of Radioactive Materials, and AOI-6, Small
Reactor Coolant System Leak. The Auxiliary Building was evacuated and
i posted as an airborne radiation area. The operators placed excess
letdown in service and secured the normal charging and letdown flow-
paths.
. A few minutes later, a fire watch monitoring temperatures in various
pipe chases reported a high temperature in the Unit 2 EL690 pipe chase.
The Unit 2 Assistant Shift Engineer (ASE) responded to the area and
encountered two electricians exiting the area. The electricians
reported that there was a steam leak in the pipe chase. (The
electricians were subsequently decontaminated as discussed below.) The
ASE investigated the report and determined that weld upstream of sample
valve 62-674 was leaking. The weld was located at the point where the
- .- . . - . - , ._. , . - _ - - - - .
.
. - - - - . - -. - . . ,
. _ -
. *
13
one inch sample line to the hot sample room joined the three inch
normal CVCS letdown line.
The leak rate was determined to be about 15 gpm. The licensee
estimated that approximately 600 gallons of RCS water was released
during the event. In addition, due to backleakage across a check valve
between the Volume Control Tank and the break, a small amount of
hydrogen was released from the VCT to the pipe chase. This leak was
promptly isolated. The licensee repaired the line and returned the
normal charging and letdown flowpaths to service on August 1, 1985.
, The licensee removed the segment of the sample line affected and sent
the weld to a metallurgical lab for analysis. It was determined that
the break which was in the heat affected zone above the weld was due to
- fatigue from high cycle vibration. Two initiation points approximately
'
180 degrees apart were observed. The licensee stated that these points
were due to high cycle, low stress fatigue. The break propagated about
300 degrees. The licensee has evaluated the configuration and has
installed a hanger on the line. The installation will be evaluated to
assure that the vibration is corrected. The weld on the Unit I sample
line was visually examined, and no defects were identified. An
appropriate hanger configuration will be installed on Unit I when the
Unit 2 analysis is complete. Completion of the harger work will be
- followed by the inspector and is identified as Inspector Followup Item
(327,328/85-26-10).
Eleven personnel suffered skin contamination as a result of tne primary
leak described above. The most severe case was 11,000 dpm on one
person's face. All personnel were decontaminated using normal methods
(showers) and had no detectable contaminatica after they were
decontaminated.
On July 30, 1985, the licensee posted the control building and an area
adjacent to the entrance to the Auxiliary Building on EL690 as airborne
areas. The air samples from these areas had been analyzed in the plant
chemistry lab. The readings were later determined to be erroneous due
to the high background in the lab by sending samples to the Power
Operations Training Center laboratory for analysis. These samples
indicated no airborne radiation was present.
While placing the Auxiliary Building general supply fans back in
service, three Auxiliary Building isolations occurred due to spiking on
0-RM-90-1018. The licensee stated that the setpoint on this monitor
was reset to a higher value which was still within the range required
to meet Technical Specification 3.11.2.1. Verification of the setpoint
change by the inspector is identified as Inspector Followup Item 327,
328/85-26-08. The Auxiliary Building Vent System was returned to
service with the Auxiliary Building Gas Treatment System operating to
reduce airborne levels in the Auxiliary Building.
No violations or deviations were identified.
i
.-. - _ - - _ - - , - -
_
l
. *
14
11. Review of Licensee Actions on NRC Information Notice 84-31 (92703)
The inspectors examined the licensee's handling of. NRC Information Notice
-
84-31, Increased Stroking Time of Bettis Actuators Because of Swollen
Ethylene - Proplyene Rubber Seals and Seal Set, dated April 30, 1984. The
information notice described the problem as follows:
The G. H. Bettis Company is a supplier of actuators used principally in
heating, ventilating and air-conditioning (HVAC) safety-related systems.
The G. H. Bettis Company notified the. NRC via a Part 21 report that their
NCB series, N52X, N72X, N73 series, and the NT310-SR4 and 5 and NT312-SR5
- actuators had potential stroking times of greater than the required 15
seconds because the EP elastomers in contact with the Mobil 28 grease
l lubricant could swell. (The 15-second stroking time was used by Bettis as
typical of customer requirements.) The actuator seals swell when in contact
with the Mobile 28 grease currently used in the manufacture of "N" series
actuators. Where it is necessary to replace swollen seals, Bettis
,
'
recommended replacing them with new seals and using Dow-Corning Molykote 44
grease, a silicon based lubricant which Bettis states has been shown to
7
cause no seal degradation and adequate lubrication.
.
The G. H. Bettis Company also identified another problem that could ,
adversely affect stroking time. Their report states that ". . .the magnitude ;
of stroking time degradation is related to the elapsed time between actuator
i
cycles. The longer the actuator remains stationary the more " set" the seals
, take. The set characteristic causes the seal to form an intimate contact
1
with the sealing surfaces, further increasing the time required to
initialize stroke. Once the actuator begins to stroke, the seals begin to
recover their original shape, thus freeing the unit up. Stroking the
actuator three or more complete cycles using pressurized gas will cause the
seals to recover sufficiently to reduce stroking time to a minimum. No seal
degradation has been traced to periodic actuator stroking, quite the
'
opposite has been experienced. Frequent stroking tends to extend seal life ,
resulting in longer actuator cycle life."
The inspectors reviewed a memorandum from H. A. Abercrombie, Director of
.
Nuclear Services, to Sequoyah and other sites, dated August 22,. 1984
! indicating that all safety-related valves and dampers of the model series
! described in the notice should have the seals and lubricant replaced at the
j first available outage. The memorandum requested that a search be made of
site documentation in order to identify the valves and dampers involved. .t
! Twenty seven (27) valves and dampers were identified at Sequoyah and three
l Nonconformance Reports (NCRs) were . written. The NCRs with pertinent
, information are as follows:
a. NCR EEB 84-12 dated December 1984 involved valves 1-FCV-77-420 and
2-FCV-77-421. Both of these valves were still in the warehouse and
have been tagged as not to be used.
l b. NCR MEB 84-07 dated September 1984 involved 17 valves used in three
j separate areas.
- - _ - _ . _ ~ _ - - . -
. , . _ - .
. -
15
1. Three valves are used to actuate the vacuum breaker system for
containment and come under ASME Section XI rules for testing.
These valves have a maximum allowed stroking time of 25 seconds
and must be tested quarterly. The latest test (June 26, 1985)
indicated stroking times for the three valves ranged from 6.4 to
6.8 seconds. The three valve numbers are 2-FCV-30-46,
2-FCV-30-41, and 2-FCV-30-40,
2. Ten valves are used to actuate the Emergency Gas Treatment System.
Each train is tested every other month but each of the valves is
not tested individually to determine stroke time. The fastest the
system has to actuate is 38 seconds and no problems have been
roted during the testing.
3. Four valves are Control Room HVAC isolation valves. This system
is required to be tested every 18 months and was last tested
August 17, 1984 with no problems. The four valve numbers are
0-FCV-31A-105A, 0-FCV-31A-105B, 0-FCV-31A-106A and 0-FCV-31A-106B.
The failure evaluation / engineering report (FE/ER) classified the
deficient condition to be a Category 1 (acceptable for all modes of
operation and design condition) based upon a sampling of the valves for
stroking time,
c. NCR MEB 84-08, Rev. 1, dated October 1984 involved 8 valves installed
in the fifth vital battery room for protection from tornado depressuri-
zation. The eight valve numbers- are FCO-51-485, FCO-31-486,
FC0-31-488, FCO-31-489, FCO-31-493, FCO-31-494 and FC0-31-501. The
FE/ER classified the deficient condition to be a Category I based on
the fact that the valves were not installed in the system, and the
- seals and lubricant could be changed before the valves would experience
operational use. This was not done and this violates 10 CFR 50
LAppendix B Criterion XVI in that effective corrective action dictated
by the FE/ER was not taken. However, no violation will be issued since
programmatic corrective actions are currently in progress at TVA due to
,
an Order Modifying Licenses issued June 14, 1985 (EA 85-49).
- Correction of this specific deficiency is an -Inspector Followup Item
(327,328/85-26-09).
!
,