IR 05000706/2008005

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 850706-0805
ML20135G033
Person / Time
Site: Sequoyah, 05000706  
Issue date: 09/06/1985
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML20135G032 List:
References
50-327-85-26, 50-328-85-26, NUDOCS 8509180069
Download: ML20135G033 (2)


Text

f

.

a

,

ENCLOSURE 1 NOTICE OF VIOLATION Tennessee Valley Authority Docket Nos. 50-327 and 50-328 Sequoyah Units 1 and 2 License Nos. DPR-77 and DPR-79 The following violations were identified during an inspection conducted on July 6 - August 5,1985. The Severity Levels were assigned in accordance with the NRC Enforcement Policy (10 CFR Part 2, Appendix C).

1.

Technical Specification 6.8.1 requires that written procedures be implemented and maintained covering safety-related activities stated in Appendix A of Regulatory Guide 1.33, Revision 2, which includes use of Administrative Procedures.

The licensee has established Administrative Instruction, AI-12, Adverse Conditions and Corrective Actions, to provide measures which assure that conditions adverse to quality are promptly identified, documented, and corrected, and that actions are taken to prevent their recurrence.

Contrary to the above, the licensee failed to implement AI-12 in that documented identification and appropriate corrective actions were not taken to reduce vibration of an Individual Rod Position Indication (IRPI) module.

Instead, a paper wedge was placed between IRPI modules by plant operators in an attempt to reduce vibration and prevent the modules from becoming electrically disconnected while required to be operable.

This is a Severity Level IV violation (Supplement I).

This violation applies to Unit 2 only.

2.

Technical Specification 6.11 requires that procedures be prepared consistent with the requirements of 10 CFR Part 20 and shall be approved, maintained and adhered to for all operations involving personnel radiation exposure.

The licensee has established Radiological Control Instructions RCI-1, Radiological Hygiene Control, and RCI-14, Radiation Work Permit (RWP)

Program, to meet certain of these requirements.

RCI-1 states that whole body frisking is required when exiting a contamination zone to prevent spread of contamination to other areas. RCI-14 requires each employee to be responsible for meeting the requirements listed on the RWP and RWP Timesheet.

RWP 02-0-85663, issued for entry to the waste gas compressor room on July 16, 1985, required a whole body frisk upon exit from the contaminated area.

Contrary to the above, on July 16, 1985, two licensee employees failed to parform a whole body frisk upon exit from the waste gas compressor room.

This is a Severity Level V violation (Supplement IV).

8509180069 850906 PDR ADOCK 05000327 G

PDR

r l

.

.

,

Tennessee Valley Authority

Docket Nos. 50-327 and 50-328 Sequoyah Units 1 and 2 License Nos. OPR-77 and DPR-79 Pursuant to 10 CFR 2.201, you are required to submit to this office within 30 days of the date of this Notice, a written statement or explanation in reply, including:

(1) admission or denial of the alleged violations; (2) the reasons for the violations if admitted; (3) the corrective steps which have been taken and the results achieved; (4) corrective steps which will be taken to avoid further violations; and (5) the date when full compliance will be achieved.

.

Security or safeguards information should be submitted as an enclosure to facilitate withholding it from public disclosure as required by 10 CFR 2.790(d)

or 10 CFR 73.21.

SEP 0 61985 Date:

.

-x r

r ~

e

-

r,. - -,

.y

-

y-

' -,

, gre,

,s y-~

-