Telecopy AO 75-15:on 750210,setpoint Shift Found on Recirculation Pump DPIS-2-2-138A.Caused by Setpoint Shift. Cam Follower Replaced & Properly Aligned.Switch Recalibr & Checked
ML20086K396
Person / Time
Site: Peach Bottom Constellation icon.png
Issue date: 02/11/1975
From: Ullrich W
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20086K384 List:
References
AO-75-15, NUDOCS 8401270067
Download: ML20086K396 (1)