c-fxO O
PHILADELPHIA ELECTRIC CdMPANY
. ::a n oh;/.N 23O1 MARKET STREET PHILADELPHIA, PA.19101 p,
p
((Off
- N?$ L I
12:51 e414ooo Y
x
$.k [, - U" h/h November 26, 1975
'Q.
~
-7Q /
Mr. Roger S. Boyd
' ~. i.a -
Acting Director Division of Reactor Licensing Office of Nuclear Reactor Regulations United States Nuc1 car Regulatory Cor: mission Washington, DC 20555
Dear Mr. Boyd:
Subject:
Abnormal Occurrence The following occurrence was reported to Mr. Walt Baunack, Region 1, Office of Inspection and Enforcement, United States Nuclear Regulatory Comission on November 17, 1975 Written notification was made to Mr. James P. O'Reilly, Region 1, Office of Inspection and Enforcement, United States Nuclear Regulatory Commission on November 17, 1975 In accordance with Section 6.7 2.A of the Technical Specifications, Appendix A of DPR-44 f or Uni t 2 Peach Bottom Atomic Power Station, the following report is being submitted to the Directorate of Reactor Licensing as an Abnormal Occurrence.
Reference:
License Number DPR-44 Technical Specification
Reference:
Table 3 2.8 Report No.:
50-277-75-74 Report Date:
November 26, 1975 Occurrence Date:
November 16, 1975 Facility:
Peach Bottom Atomic Power Station R.D. 1, Delta, Pennsylvania 17314 Identification of Occurrence:
Setpoint of RCIC steam supply line area high temperature switch, TE-TS 4939A, was found to be less conservative than that specified by the Technical Specifications.
Conditions Prior to Occurrence:
Unit 2 shutdown, reactor vessel head removed for scheduled outage work.
Description of Occurrence:
During a routine instrument surveillance test the setpoint of TE-TS 4939A was f ound to have drif ted 2 F above the Technical Speci-f fication limit of 2000F.
f 8401090626 751126 99PY SENf
'IDW-N PDR ADOCK 05000277 991 c-Wn
O O
Mr. Roger S. Boyd 50-277-75-74 November 26, 1975 Page 2
_ Designation of Acoarent Cause of Occurrence:
Slight setpoint drift.
Analysis of Occurrence:
Because the setpoint drif t was slight and because the setpoints of the other 3 temperature switches in the 1 out of 2 twice logic were found within technical specification limits when checked, the safety implications of this occurrence are minimal.
Corrective Action:
The switch was immediately recalibrated, tested, and returned to service.
Failure Data:
None previous.
Very truly yours, M.
. Cooney S erintendent Generation Division - Nuclear cc: