ML20203L038

From kanterella
Revision as of 10:09, 31 December 2020 by StriderTol (talk | contribs) (StriderTol Bot change)
Jump to navigation Jump to search
Notifies That 10% Sample Plan Selected & Will Be Implemented for Snubber & Functional Testing During First Refueling Outage,Per NUREG-1117,Section 4.7.8e
ML20203L038
Person / Time
Site: Waterford Entergy icon.png
Issue date: 08/14/1986
From: Cook K
LOUISIANA POWER & LIGHT CO.
To: Martin R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
RTR-NUREG-1117 W3P86-1933, NUDOCS 8608220338
Download: ML20203L038 (1)


Text

__.

+ P. O. BOX 60340 LOUISI& ANA POWER LIGHT / 317NEW BARONNESTREET ORLEANS, LOUISIANA 70160 +

(504)595-3100

$0$

u EsN!0 August 14, 1986 W3P86-1933 A4.05 QA Mr. Robert D. Martin Regional Administrator, Region IV i h

} ,

U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000 EI5% 1

I j

Arlington, TX 76011 , _ gg

Subject:

Waterford 3 SES Docket No. 50-382 License No. NPF-38 Functional Tests of Snubbers

Dear Mr. Martin:

Pursuant to Section 4.7.8e of the Waterford 3 Technical Specifications (NUREG-1117), Louisiana Power and Light Company hereby provides notification that the 10% sample plan (T.S. 4.7.8.e(l)) has been selected and will be implemented for the snubber sampling and functional testing during the first refueling outage.

Very truly yours, rT Zb/ Om [L K.W. Cook Nuclear Support & Licensing Manager l

KWC:GEW:ssf cc: NRC, Director, Office of I&E G.W. Knighton, NRC-NRR J.II. Wilson, NRC-NRR l NRC Resident Inspectors Office B.W. Churchill W.M. Stevenson k'9 Y,hL --

P

,.i 4 5f1 b "AN EQUAL OPPORTUNITY EMPLOYER" -

fV913