MONTHYEARML23320A2472023-11-17017 November 2023 Constellation - Summary of November 14, 2023, Public Pre-Application Meeting with Constellation Energy Generation, LLC on Adoption of TSTF-591 ML23271A2682023-10-0505 October 2023 September 25, 2023, Summary of with Constellation Energy Generation, LLC on Proposed Changes to Emergency Plans ML23263B1062023-09-22022 September 2023 R. E. Ginna Nuclear Power Plant - Constellation - Pre-Application Amse 9/18/2023 Meeting Summary ML23179A0012023-06-28028 June 2023 6/7/2023 - Annual Assessment Meeting for Pa/Md/Ny/Nj Nuclear Power Plants - Meeting Summary ML23055A0352023-03-24024 March 2023 Summary of February 23, 2023, with Constellation Energy Generation, LLC on Proposed Changes to Emergency Plans to Revise Emergency Action Levels ML22187A1462022-07-0606 July 2022 Joint Annual Assessment Meeting for Pa/Md/Nj/Ny Nuclear Power Plants - Meeting Summary ML21333A1532021-11-30030 November 2021 Summary of November 16, 2021, Meeting with Exelon Generation Company, LLC Regarding a Planned Request for an Alternative to Extend the Inservice Inspection Interval ML21237A0412021-08-30030 August 2021 Summary of the July 27, 2021, Meeting with Exelon Generation Company, LLC Regarding a Planned Request to Use Case OMN-28, ML21176A0822021-07-0606 July 2021 June 15, 2021, Summary of Meeting with Exelon Generation Company, LLC Vessel Nozzle Repair Related to a Planned Request for an Alternative Related to Reactor Pressure ML21139A1852021-06-22022 June 2021 Summary of Meeting with Exelon Generation Company, LLC Regarding Its Requested Alternative to Eliminate Certain Documentation Requirements for the Replacement of Pressure Retaining Bolting ML21011A2822021-01-21021 January 2021 Summary of January 6, 2021, Presubmittal Meeting Between the NRC and Exelon Generation Company, LLC Regarding Licensing Activities to Support the Planned Early Closures of Byron, Unit Nos. 1 and 2 and Dresden, Units 2 and 3 ML20351A2832020-12-18018 December 2020 Summary of Meeting with Exelon Generation Company, LLC Regarding a Planned Request for an Exemption to Reduce the Frequency of Updates to Its Inservice Testing and Inspection Programs ML20342A3522020-12-10010 December 2020 Summary of November 13, 2020, Meeting with Exelon Generation Company, LLC Regarding a Planned Request for an Alterantive to Certain Documentation Requirements for the Replacement of Pressure Retaining Bolting (EPID-L-2020-LRM-0102) ML20323A0332020-12-0101 December 2020 Summary of November 4, 2020, Meeting with Exelon Generation Company, LLC Regarding a Planned Request for an Alternative to Reduce the Frequency of Updates to Its Inservice Testing and Inspection Programs ML20205L3712020-07-23023 July 2020 and R.E. Ginna Nuclear Power Plant Summary of Meeting ML20163A1722020-06-12012 June 2020 Summary of June 9, 2020, Pre-Submittal Meeting with Exelon Generation Company, LLC, Regarding Planned License Amendment Request to Modify Surveillance Requirement 3.6.1.3 ML19326C3582019-12-0303 December 2019 Summary of November 20, 2019, Meeting with Exelon Generation Company, LLC Regarding a Planned Request to Revise the Quality Assurance Program ML19326A3152019-12-0303 December 2019 Summary of November 18, 2019, Meeting with Exelon Generation Company, LLC Regarding a Planned Request for an Alternative to Supplemental Valve Position Indication Testing Requirements ML19302F8772019-11-0404 November 2019 Summary of the October 28, 2019, Meeting with Exelon Generation Company, LLC, Regarding a Planned Supplement to a License Amendment Request Regarding Revising the Allowable Value for Reactor Water Cleanup System Isolation ML19291A0022019-11-0101 November 2019 10/03-10/08/2019 Summary of Meetings with Exelon Generation Company, LLC, on Emergency Amendment Request Regarding One-Time Extension to Technical Specifications 3.8.1 Action A.3 Completion Time for Inoperable Offsite Source (EPID L-2019-LL ML19302D3152019-10-28028 October 2019 Annual Assessment Meeting for James A. Fitzpatrick Nuclear Power Plant and Nine Mile Point Nuclear Generating Station - Meeting Summary ML19176A0042019-07-15015 July 2019 Summary of Meeting with Exelon Generation Company, LLC, on a Planned License Amendment Request Regarding the Relaxation of Containment Differential Pressure Requirements ML19183A1282019-07-15015 July 2019 Summary of June 20, 2019, Meeting with Exelon Generation Company, LLC, on a Planned License Amendment Request Regarding Main Steam Isolation Valve Leak Rate Increase Utilizing ML19162A0272019-06-21021 June 2019 Summary of June 4, 2019, Meeting with Exelon Generation Company, LLC Regarding a Planned Request to Extend the Test Interval for Safety Relief Valves ML19036A8832019-02-0707 February 2019 Summary of Meeting with Exelon Generation Company, LLC Regarding a Planned Request to Use ASME Code Case N-879 ML18354B1712019-01-0202 January 2019 Summary of December 19, 2018, Meeting with Exelon Generation Company, LLC Regarding the Use of Boiling Water Reactor Vessel and Internals Project Guidelines ML18347B4932019-01-0202 January 2019 Summary of Pre-Application Meeting with Exelon Generation Co., LLC (Exelon) Forthcoming License Amendment Requests to Revise Technical Specification Requirements for Main Steam Isolation Valve Leak Rate Tests ML18325A1712018-11-28028 November 2018 Summary of Meeting with Exelon Generation Company, LLC Regarding Planned Fleet License Amendment Request to Revise Technical Specifications for High Radiation Areas ML18304A1662018-11-0606 November 2018 Summary of October 23, 2018, Teleconference with Exelon Generation Co., LLC to Discuss Potential License Amendment Request Ultimate Heat Sink Bar Rack Bar Heaters ML18297A1722018-10-26026 October 2018 Summary of Meeting with Exelon Generation Company, LLC Regarding Planned License Amendment Request to Adopt TSTF-427 ML18262A3662018-09-18018 September 2018 August 21, 2018, James A. Fitzpatrick Nuclear Power Plant (Fitzpatrick) and Nine Mile Point Nuclear Generating Station (Nine Mile Point) Summary of Public Meeting ML18163A2682018-06-19019 June 2018 Summary of June 5, 2018, Teleconference with Exelon Generation Company, LLC to Discuss Emergency Plan Changes at James A. Fitzpatrick Nuclear Power Plant and Nine Mile Point Nuclear Station ML18120A1772018-05-0101 May 2018 Summary of Meeting with Exelon Generation Company, LLC Regarding Draft Guidance for Emergency Response Organization Staffing ML18107A4972018-04-27027 April 2018 April 10, 2017, Summary of Public Meeting with Entergy Nuclear Operations, Inc. Regarding Upcoming License Amendment Request to Add Setpoint Verification Requirement to Technical Specification Surveillance Requirements ML17256A7482017-09-28028 September 2017 Summary of September 5, 2017, Meeting with Exelon Generation Co., LLC to Discuss Potential License Amendment Request Technical Specifications Task Force Traveler TSTF-542, Revision 2, for James A. Fitzpatrick Nuclear Power Plant ML17216A1732017-09-0707 September 2017 Notice of Meeting with Florida Power & Light Company and NextEra Energy to Discuss Closing Out Generic Safety Issue-191 and Generic Letter 2004-02 ML17144A2852017-06-0202 June 2017 Summary Teleconference with Exelon Generation Company, LLC, on Planned Submittals of License Amendment Requests to Change Emergency Action Levels Associated with Lake Ontario Water Level ML17143A3582017-05-23023 May 2017 Summary of Public Meeting for James A. Fitzpatrick and Nine Mile Point ML17143A1902017-05-23023 May 2017 Public Meeting Handouts and Sign in Sheet ML17031A2802017-02-0808 February 2017 Summary of Teleconference with Entergy Nuclear Operations, Inc. Regarding Verbal Authorization for Relief Request RR-21 for the James A. Fitzpatrick Nuclear Power Plant ML16229A4542016-08-16016 August 2016 Summary of Annual Assessment Meeting for James A. Fitzpatrick Nuclear Power Plant ML15197A3332015-07-24024 July 2015 June 29, 2015 Summary of Meeting with Beyond Nuclear, Et. Al., Regarding Its 10 CFR 2.206 Petition Requesting Enforcement Action Against the James A. FitzPatrick Nuclear Power Plant ML15120A0212015-04-28028 April 2015 April 23, 2015, Summary of Annual Assessment Meeting for James A. FitzPatrick Nuclear Power Plant on 4/23/2015 ML14197A5832014-09-18018 September 2014 Summary of the June 19, 2014, Category 1 Public Meeting with Entergy to Discuss Seismic Hazard Reevaluations Associated with Implementation of Japan Lessons-Learned Near-Tear Task Force Recommendation 2.1 ML14086A1532014-03-26026 March 2014 Summary of Annual Assessment Meeting for Nine Mile Point Nuclear Station and James A. FitzPatrick Nuclear Power Plant on 3/18/2014 ML13100A1172013-04-10010 April 2013 Summary of Public Meeting Regarding Nine Mile Point Nuclear Station and James A. Fitzpatrick Nuclear Power Plant ML13162A5812012-07-19019 July 2012 PRB Closed Meeting Notes - 07/19/12 Gunter Et Al. 2.206 Requesting Enforcement Action Against James A. Fitzpatrick Plant ML13162A5802012-05-29029 May 2012 PRB Closed Meeting Notes - 05/29/12 Gunter Et Al. 2.206 Requesting Enforcement Action Against James A. Fitzpatrick Plant ML12102A1752012-04-11011 April 2012 and James A. FitzPatrick Nuclear Power Plant - Summary of Public Meeting on March 22, 2012 ML13162A6282012-03-20020 March 2012 by Larry Doerflein: PRB Notes Attached-Dial-In Provided 2023-09-22
[Table view] Category:Memoranda
MONTHYEARML21277A2472021-11-0505 November 2021 Notification of Significant Licensing Action - Proposed Issuance of Order Approving the Transfer of Licenses for Which a Hearing Has Been Requested - Exelon Generation Company, LLC; Et. Al ML21285A1492021-10-22022 October 2021 Audit Plan in Support of Review of License Amendment Requests Regarding 50.69/TSFT-505 ML21056A5452021-03-30030 March 2021 Memorandum to File: Final Environmental Assessment and Finding of No Significant Impact for Initial and Updated Decommissioning Funding Plans for FitzPatrick ISFSI ML20038A2692020-02-11011 February 2020 Sensitive Unclassified Non-Safeguards Information Review of 2019 Final Safety Analysis Report Change Pages ML19099A2672019-04-16016 April 2019 Use of Encryption Software for Electronic Transmission of Safeguards Information ML17142A2382017-05-25025 May 2017 OEDO-17-00280 - Briefing Package for Drop-In Visit on June 9, 2017, by Senior Management of Exelon Generation Company, LLC with Chairman Svinicki, Commissioner Baran, and Commissioner Burns ML16336A4992017-01-18018 January 2017 Notice of Significant Licensing Action ML16088A2052016-03-28028 March 2016 Enclosure 1 - (72.30 DFP Reviews to Be Completed 2015) - Memo T Bowers from s Ruffin, Technial Assistance Requests - Review 2015 Tri-Annual Decommissioning Funding Plans for Multiple Independent Spent Fuel Storage Installations ML16088A2042016-03-28028 March 2016 Memo T Bowers from s Ruffin, Technical Assistance Requests - Review 2015 Tri-Annual Decommissioning Funding Plans for Multiple Independent Spent Fuel Storage Installations W/ Encl 2 (Template) ML15197A3272015-07-24024 July 2015 Audio Recording of June 29, 2015 Public Meeting with Paul Gunter Et. Al., Regarding Their 10 CFR 2.206 Petition Requesting Enforcement Action ML13309A0802013-12-11011 December 2013 Memorandum to File: Transcript for 10 CFR 2.206 Petition from Beyond Nuclear (Et Al) Regarding General Electric Mark I and Mark II Boiling-Water Reactors ML13108A3282013-04-22022 April 2013 Notice of Forthcoming Meeting with Petitioners Requesting Action Against Entergy Nuclear Operations, Inc., Regarding Operations at FitzPatrick, Pilgrim, and Vermont Yankee Nuclear Power Stations (TAC Nos. MF1092, MF1093, and MF1094) ML12290A2872012-11-0808 November 2012 Final Fitzpatrick Rotating Quadrants TIA Response ML13022A3542012-04-0505 April 2012 from Bhalchandra Vaida to George Wilson: G20120172/EDATS: OEDO-2012-0147 - Forthcoming Meeting with Petitioners, Beyond Nuclear Et Al, Requesting Action Under 10 CFR 2.206 ML12095A1712012-04-0505 April 2012 G20120172/EDATS-OEDO-2012-0147-ME8189-Meeting Notice-1st Meeting with Petitioners ML13017A3572012-04-0505 April 2012 from R1DRPMail Resource to Sam Mccarver: FW Fitzpatrick G20120172/EDATS ML11250A1712011-09-14014 September 2011 Notice of Forthcoming Meeting with Petitioner Requesting Action Under 10 CFR 2.206 Regarding Immediate Suspension of the Operating Licenses of General Electric (GE) Mark 1 Boiling Water Reactors (Bwrs) ML1115704052011-06-0606 June 2011 Notice of Meeting with Entergy Operations, Inc., to Discuss Implementation of Quality Oversight and Verification Programs at Entergy Sites Including Actions Being Taken to Enhance Effectiveness ML11126A0962011-05-12012 May 2011 Notice of Meeting with Petitioner Requesting Action Under 10CFR2.206 Regarding Immediate Suspension of Operating Licenses of General Electric Mark 1 Boiling Water Reactors ML1107504052011-03-21021 March 2011 Notice of Meeting with Entergy Operations, Inc., to Discuss Fleetwide Submittal for Proposed Technical Specification and Quality Assurance Program Manual Changes Related to Unit Staff Qualification Requirements ML0927301372009-10-0909 October 2009 Safety Evaluation by the Office of Nuclear Reactor Regulation Corporate Restructuring Conversion of Companies and Stock Split-Off by Entergy Nuclear Operations, Inc and Subsidiaries ML0917301322009-06-25025 June 2009 06/07-11/2009-Report on Trip to the Institute of Electrical and Electronics Engineers Stationary Battery Committee Meeting in Rohnert Park, CA ML0913405542009-05-14014 May 2009 Summary of Annual Assessment Open-House Public Meeting with Nine Mile Point and FitzPatrick ML0808000342008-03-24024 March 2008 Docketing of Slides Presentations to ACRS Full Committee Meeting Pertaining to License Renewal Application of the James A. Fitzpatrick Nuclear Power Plant ML0807400842008-03-14014 March 2008 Draft Regulatory Guide for Comment ML0806700322008-02-19019 February 2008 Status Report and Proposed Schedule for FitzPatrick License Renewal at Full Committee Meeting on March 6, 2008 ML0803601492008-02-14014 February 2008 Advisory Committee for Reactor Safeguards Review of the James A. FitzPatrick Nuclear Power Plant, License Renewal Application - Safety Evaluation Report ML0801402662008-02-0808 February 2008 Audit Q&A Database for FitzPatrick Nuclear Plant Aging Mgmt Programs, Aging Mgmt Reviews, and Time-Limited Aging Analyses - Audit Team'S Evaluation of the Applicant'S Responses ML0801505342008-01-24024 January 2008 01/11/2008 Summary of a Telephone Conference Call Between the NRC and Entergy Nuclear Operations, Inc., Concerning the 115kV AC Power Supply Connection Pertaining to the James A. FitzPatrick Nuclear Power Plant License Renewal Application ML0720000582007-07-26026 July 2007 7/18/07 Public Meeting Summary on the Reactor Oversight Process ML0717803562007-07-12012 July 2007 Summary of Telephone Conference Call Held on June 7, 2007, (FitzPatrick) ML0711504622007-05-0707 May 2007 Trip Report Summarizing March 27, 2007 Visit to James A. FitzPatrick Nuclear Power Plant Regarding the License Renewal Environmental Review ML0706702272007-03-15015 March 2007 Summary of Telephone Conference Calls Held on January 31, 2007 and February 13, 2007, Between the U.S. NRC and Entergy Nuclear Operations, Inc., Pertaining to the James A. Fitzpatrick Nuclear Power Plant, LRA ML0706702662007-03-14014 March 2007 Summary of Telephone Conference Call Held on March 5, 2007, Between the NRC and Entergy Nuclear Operations, Inc., Concerning Draft Request for Additional Information Pertaining to the James A. Fitzpatrick Nuclear Power Plant, LRA ML0634502502006-12-19019 December 2006 November 2006 Report on the Status of Public Petitions Under Title 10 of the Code of Federal Regulations, Section 2.206 ML0627801872006-10-23023 October 2006 Memorandum - Audit and Review Plan for Plant Aging Management Reviews and Programs, and Time-Limited Aging Analyses for the James A. Fitzpatrick Power Plant ML0626803552006-09-25025 September 2006 10/12/2006 Notice of Forthcoming Meeting to Discuss the License Renewal Process and Environmental Scoping for James A. Fitzpatrick Nuclear Power Plant, License Renewal Application Review ML0615806052006-06-0707 June 2006 06/26/2006 Forthcoming Pre-application Meeting with Entergy Nuclear Operations, Inc. on the License Renewal Application for James A. Fitzpatrick Nuclear Power Plant ML0600300802006-02-17017 February 2006 Transmittal of Final ASP Analyses (August 14, 2003 Grid Disturbance Events) ML0601201072006-01-27027 January 2006 Final Response to Task Interface Agreement 2005-10 Related to Operability Determination on Through-Wall Cracking of a Torus ML0506104872005-03-23023 March 2005 Draft Information Memo - May 1, 2005 Thru May 27, 2005 ML0433603982005-01-0404 January 2005 November 2004, Memo., from Brian W. Sheron, Nrr/Adpt to Luis A. Reyes, Nrc/Edo, Report on the Status of Public Petitions Under Title 10 of the Code of Federal Regulations, Section 2.206 ML0410507202004-03-31031 March 2004 Memo from D. Burch to File: RI-97-A-0126, Regarding FitzPatrick ML0405806902004-02-27027 February 2004 Transmittal of Preliminary ASP Analyses for Peer Review (August 14, 2003 Grid Event) ML0215803662002-06-0606 June 2002 Memo to R. Bellamy, RGN-I from: M. Tokar Subject: Region I Independent Spent Fuel Storage Installation Inspection Plans Attachment: Sfpo Comments to Region I Integrated Inspection Plans ML0207804562002-03-20020 March 2002 Memo, Draft Information for March 1 to March 15, 2002 ML0207704622002-03-20020 March 2002 Attachment Draft Information for March 1 to March 15, 2002 Requests for Additional Lnformation ML0200301552002-01-25025 January 2002 Memo to W.D. Beckner Closure of FitzPatrick Beyond Scope Issues (Bsis) BSI-F12 (Tac No. MB2710) NRC Generic Letter 1989-111989-06-30030 June 1989 NRC Generic Letter 1989-011: Resolution of Generic Issue 101 Boiling Water Reactor Water Level Redundancy 2021-03-30
[Table view] Category:Request for Additional Information (RAI)
MONTHYEARML24024A1372024-01-24024 January 2024 NRR E-mail Capture - Final Snsb RAI Regarding FitzPatrick Amendment to Modify Safety Relief Valves Setpoint Lower Tolerance ML24018A0012024-01-18018 January 2024 Notification of Commercial Grade Dedication Inspection (05000333/2024010) and Request for Information ML23264A7992023-09-21021 September 2023 NRR E-mail Capture - Final RAI - Constellation Energy Generation, LLC Fleet Request License Amendment Request to Adopt TSTF-580, Revision 1 ML23164A0322023-06-13013 June 2023 Request for Information for a Biennial Problem Identification and Resolution Inspection; Inspection Report 05000333/2023010 ML22321A0102022-11-17017 November 2022 Notification of Conduct of a Fire Protection Team Inspection ML22124A2672022-05-0404 May 2022 Request for Additional Information for James A. FitzPatrick Nuclear Power Plant TSTF-505 ML22041B5362022-02-10010 February 2022 NRR E-mail Capture - Constellation Energy Generation, LLC - Request for Additional Information Regarding Fleet License Amendment Request to Adopt TSTF-541 ML22020A0642022-01-13013 January 2022 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding Proposed Fleet Alternative for Repair of Water Level Instrumentation Partial Penetration Nozzles ML21256A1902021-09-10010 September 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding License Transfer Application ML21187A0522021-07-0606 July 2021 Fitz RAI Regarding FitzPatrick Amendment Request to Modify SR 3.5.1.6 ML21144A2132021-05-24024 May 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding License Transfer Application ML21062A0652021-03-0101 March 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding Proposed Fleet Alternative to Documentation Requirements for Pressure Retaining Bolting ML21049A2572021-02-18018 February 2021 Request for Additional Information Byron/Dresden Proposed Changes to Site Emergency Plans to Support Post-Shutdown and Permanently Defueled Conditions (EPID-2020-LLA-0240 & EPID-2020-LLA-0237) ML21041A1932021-02-10010 February 2021 Request for Information for a Triennial Baseline Design-Basis Capability of Power-Operated Valves Under 10 CFR 50.55a Requirements Inspection; Inspection Report (05000333/2021011) ML20066L3682020-03-0505 March 2020 Request for Additional Information: License Amendment Request for Change to the Technical Specifications to Revise the Allowable Value for Reactor Water Cleanup (RWCU) System Primary Containment ML20056E7992020-02-25025 February 2020 Request for Additional Information for LAR on Primary Containment Hydrodynamic Loads ML20035D5762020-02-0303 February 2020 Request for Additional Information: License Amendment Request for Application of the Alternative Source Term for Calculating Loss-of-Coolant Accident Dose Consequence ML20027A0112020-01-23023 January 2020 Request for Additional Information: License Amendment Request for Change to the Technical Specifications to Revise the Allowable Value for Reactor Water Cleanup (RWCU) System Primary Containment Isolation ML19353A9452019-12-19019 December 2019 Request for Additional Information: License Amendment Request for Application of the Alternative Source Term for Calculating Loss-of-Coolant Accident Dose Consequences ML19322A0062019-11-15015 November 2019 NRR E-mail Capture - Fermi 2: Request for Additional Information- Relief Request VRR-006, Proposed Alternative for Preservice Testing of Butterfly Valves ML19280A0372019-10-0505 October 2019 NRR E-mail Capture - FitzPatrick Revised Request for Additional Information: Emergency Amendment to Extend Completion Time of Transformer to 21 Days ML19280A0392019-10-0505 October 2019 NRR E-mail Capture - FitzPatrick Additional Request for Additional Information: Emergency Amendment to Extend Completion Time of Transformer to 21 Days ML19280A0362019-10-0404 October 2019 NRR E-mail Capture - FitzPatrick Request for Additional Information: Emergency Amendment to Extend Completion Time of Transformer to 21 Days ML19099A2672019-04-16016 April 2019 Use of Encryption Software for Electronic Transmission of Safeguards Information ML19099A2852019-03-12012 March 2019 Draft RAI: FitzPatrick Request to Update Electronic Transmission of Safeguards Information ML19025A1202019-01-24024 January 2019 NRR E-mail Capture - Calvert Cliffs, Fitzpatrick, and Nine Mile Point - Request for Additional Information Regarding License Amendment Request to Revise Emergency Response Organization Staffing ML18353B5112018-12-20020 December 2018 Request for Additional Information Relief Request No. 14R-22, for Fourth 10-Year Inservice Inspection Interval ML18164A3652018-06-13013 June 2018 NRR E-mail Capture - FitzPatrick RAIs - LAR to Adopt EAL Schemes Pursuant to NEI 99-01, Revision 6 ML18094B0922018-04-0505 April 2018 Enclosurequest for Additional Information (Letter to B. S. Ford RAI Regarding Entergy Operations, Inc.'S Decommissioning Funding Plan Update for ISFSI Docket Nos.: 72-43, 72-51, 72-1044, 72-07, 72-12, and 72-59) ML18085A6922018-03-26026 March 2018 NRR E-mail Capture - James A. FitzPatrick Nuclear Power Plant, Unit 1 - Request for Information to Adopt Traveler TSTF-542, RPV Water Inventory Control ML18085A6912018-03-23023 March 2018 NRR E-mail Capture - Draft Request for Information (RAI) for JAFNPP Traveler TSTF-542, RPV Water Inventory Control ML18029A8422018-01-29029 January 2018 NRR E-mail Capture - Request for Additional Information: FitzPatrick License Amendment Request to Revise Technical Specifications to Address Secondary Containment Personnel Access Door Openings ML17335A1002017-11-29029 November 2017 NRR E-mail Capture - FitzPatrick - Request for Additional Information - Relief Request 15R-02 Regarding the Use of BWRVIP Guidelines Instead of ASME Code (CAC: MG0116; EPID: L-2017-LLR-0083) ML17285B1962017-10-27027 October 2017 Request for Additional Information Regarding Generic Letter 2016-01, Monitoring of Neutron-Absorbing Materials in Spent Fuel Pools. ML17228A0052017-08-15015 August 2017 NRR E-mail Capture - Request for Additional Information - St. Lucie Relief Request #3 - Icw 30 Pipe Defect Removal (MF9288) ML16299A0192016-11-0202 November 2016 Request for Additional Information Regarding Direct License Transfer from Entergy to Exelon ML16287A6502016-10-21021 October 2016 Request for Additional Information Regarding: License Amendment Request to Revise Technical Specifications Section 5.5.6 for Extension of Type a and Type C Leak Rate Test Frequencies ML16280A5732016-10-18018 October 2016 Request for Additional Information Relief Request for Proposed Alternative for the Implementation of BWRVIP-05 ML16117A1862016-04-26026 April 2016 Entergy Fleet Relief Request EN-ISI-15-1 Request for Additional Information - 04/26/16 Email from R. Guzman to G. Davant (CAC Nos. MF7133-MF7136) ML16013A0642016-01-13013 January 2016 NRR E-mail Capture - Request for Additional Information Entergy CNRO-2015-00023 - Revision to Entergy Quality Assurance Program Manual (Fleet Submittal CAC Nos. MF7086-MF7097) ML15341A1662015-12-0707 December 2015 NRR E-mail Capture - Entergy Fleet RR-EN-15-1, Request for Additional Information (CACs MF6341-MF6349) ML14240A6122014-09-24024 September 2014 Request for Additional Information Regarding Proposed Changes to the Technical Specification Low Pressure Safety Limit ML14184A6152014-07-25025 July 2014 Request for Additional Information Regarding Proposed Safety Limit Minimum Critical Power Ratio License Amendment ML14195A0972014-07-16016 July 2014 Request for Additional Information Associated with Near-Term Task Force Recommendation 2.1, Seismic Hazard and Screening Report ML14164A5382014-07-0202 July 2014 Request for Additional Information Regarding 10 CFR 50.55A Alternate Request PRR-05 (Tac No. MF3680) ML14093A6772014-05-0101 May 2014 SONGS - Request for Additional Information Concerning Pre-Emption Authority ML13338A6452013-12-12012 December 2013 Interim Staff Evaluation and Request for Additional Information, Regarding the Overall Integrated Plan for Implementation of Order EA-12-051, Reliable Spent Fuel Pool Instrumentation ML13304B4182013-11-0101 November 2013 Request for Additional Information Associated with Near-Term Task Force Recommendation 2.3, Seismic Walkdowns ML13226A5342013-08-29029 August 2013 Request for Additional Information Regarding Overall Integrated Plan for Reliable Spent Fuel Pool Instrumentation (Order EA-12-051) ML13179A4622013-07-0505 July 2013 Entergy Nuclear Operations, Inc., Decommissioning Funding Status Report Request for Additional Information Regarding the Decommissioning Funding Status Report 2024-01-24
[Table view] |
Text
March 15, 2007 LICENSEE: Entergy Nuclear Operations, Inc.
FACILITY: James A. FitzPatrick Nuclear Power Plant
SUBJECT:
SUMMARY
OF TELEPHONE CONFERENCE CALLS HELD ON JANUARY 31, 2007 AND FEBRUARY 13, 2007, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND ENTERGY NUCLEAR OPERATIONS, INC., CONCERNING DRAFT REQUESTS FOR ADDITIONAL INFORMATION PERTAINING TO THE JAMES A. FITZPATRICK NUCLEAR POWER PLANT, LICENSE RENEWAL APPLICATION The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of Entergy Nuclear Operations, Inc., (ENO) held telephone conference calls on January 31, 2007 and February 13, 2007, to discuss and clarify the staffs draft requests for additional information (RAIs) concerning the James A. FitzPatrick Nuclear Power Plant, license renewal application.
The telephone conference calls were useful in clarifying the intent of the staffs RAIs. provides a listing of the participants and Enclosure 2 contains a listing of the RAIs discussed with the applicant, including a brief description on the status of the items.
The applicant had an opportunity to comment on this summary.
/RA/
Tommy Le, Sr. Project Manager License Renewal Branch B Division of License Renewal Office of Nuclear Reactor Regulation Docket No. 50-333
Enclosures:
- 1. List of Participants
- 2. List of Draft RAIs cc w/encls: See next page
ML070670227 OFFICE LA:DLR PM:RLRB:DLR BC:RLRB:DLR PM: RLRB: DLR NAME IKing TLe RAuluck K.Howard DATE 03 / 14 /07 03/ 14 /07 03/ 15 /07 03/ 13 /07 LIST OF PARTICIPANTS FROM THE TELEPHONE CONFERENCE CALL JAMES A. FITZPATRICK NUCLEAR POWER PLANT LICENSE RENEWAL APPLICATION JANUARY 31, 2007 AND FEBRUARY 13, 2007 PARTICIPANTS AFFILIATIONS Tommy Le U.S. Nuclear Regulatory Commission (NRC)
Kent Howard NRC Matthew Mitchell NRC Allison Black NRC Rick Plasse Entergy Nuclear Operations, Inc. (ENO)
Mike Stroud ENO Bob Penny ENO Joe Pahacheck ENO Don Farbinger ENO Enclosure 1
JAMES A. FITZPATRICK NUCLEAR POWER PLANT LICENSE RENEWAL APPLICATION The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of Entergy Nuclear Operations, Inc., held a telephone conference calls on January 31, 2007 and February 13, 2007, to discuss and clarify the following draft requests for additional information (RAIs) concerning Section 4.2.2, Leak Before Break for the James A. FitzPatrick Nuclear Power Plant (JAFNPP), license renewal application (LRA).
RAI 4.7.2 Leak Before Break (January 31, 2007)
Discussion: The teleconference was conducted on January 31, 2007, to discuss Section 4.7.2, Leak Before Break, of the JAFNPP LRA. The NRC questioned the use of the calculation identified in Section 4.7.2 of the LRA. The NRC staff specifically asked if the calculation supported the statement in the updated final safety analysis report (UFSAR) Section 16.3.2.2 regarding protective devices.
The applicant indicated that information in the JAFNPP UFSAR Section 16.3.2.2, addresses reactor coolant system leakage rates and leakage detection systems via the leak before break analysis. This analysis assumes that a pipe will first crack and gradually increase the amount of leakage until reaching the critical crack length at which time the crack propagates into a break. Based on this analysis, the leak detection system is designed to detect a leak before it becomes a break in lieu of the pipe restraint requirement.
After discussion about the nature of the potential time-limited aging analysis (TLAA), NRC requested the following information:
- 1. The applicant will provide supporting documentation for the purpose of performing the analysis. The applicant then provided information to the NRC that had been documented in the original plant Safety Evaluation Report (SER) Section 5.2.2 dated November 20,1972.
RAI 4.7.2 Leak Before Break (February 13, 2007)
Discussion: After the staff has reviewed the original NRC SER dated November 20,1972, another teleconference was conducted between NRC and JAFNPP personnel on February 13, 2007, to further discuss Section 4.7.2, Leak Before Break, of the JAFNPP LRA. Per discussion with the applicant, NRC staff requested that the applicant revise and resubmit LRA Section 4.7.2 after addressing the following points:
- 1. Remove all references to Leak Before Break (LBB), as the TLAA being discussed clearly predates the formal concept of Leak Before Break documented in Standard Review Plan Section 3.6.3.
Enclosure 2
- 2. Rename the section with a title that describes the primary purpose of the analysis in FSAR 16.3.2 (see also the staff's original SER for licensing of the facility, Section 5.2.2).
- 3. Discuss the specific time limited part of the original analysis and provide a description of the plant modifications (or non-installations) which were permitted based on the original analysis including locations, or systems, in the plant to which the modifications were permitted.
- 4. Conclude with an explanation of how the TLAA will be addressed in the context of the ongoing LRA review OR include a commitment to submit the completed TLAA for review at least 2 years prior to entering the period of extended operation.
Based on the above information, RAI 4.7.2 was issued to the applicant by letter dated February 23, 2007.
Memo to Entergy Nuclear Operations, Inc., from N. Le, dated March 15, 2007 DISTRIBUTION:
SUBJECT:
SUMMARY
OF TELEPHONE CONFERENCE CALLS HELD ON JANUARY 31, 2007 AND FEBRUARY 13, 2007, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND ENTERGY NUCLEAR OPERATIONS, INC., CONCERNING DRAFT REQUESTS FOR ADDITIONAL INFORMATION PERTAINING TO THE JAMES A. FITZPATRICK NUCLEAR POWER PLANT, LICENSE RENEWAL APPLICATION HARD COPY DLR RF E-MAIL:
PUBLIC RWeisman GGalletti DShum SSmith (srs3)
SDuraiswamy RidsNrrDlr RidsNrrDlrRlra RidsNrrDlrRlrb RidsNrrDlrRlrc RidsNrrDlrReba RidsNrrDlrRebb RidsNrrDci RidsNrrDra RidsNrrDe RidsNrrDeEemb RidsNrrDeEeeb RidsNrrDeEqvb RidsNrrDss RidsOgcMailCenter RidsNrrAdes GHunegs, SRI ECobey RLaufer JBoska
James A. FitzPatrick Nuclear Power Plant Mr. Gary J. Taylor Chief Executive Officer Ms. Charlene D. Faison Entergy Operations, Inc. Manager, Licensing 1340 Echelon Parkway Entergy Nuclear Operations, Inc.
Jackson, MS 39213 440 Hamilton Avenue White Plains, NY 10601 Mr. John T. Herron Sr. VP and Chief Operating Officer Mr. Michael J. Colomb Entergy Nuclear Operations, Inc. Director of Oversight 440 Hamilton Avenue Entergy Nuclear Operations, Inc.
White Plains, NY 10601 440 Hamilton Avenue White Plains, NY 10601 Mr. Peter T. Dietrich Site Vice President Mr. David Wallace Entergy Nuclear Operations, Inc. Director, Nuclear Safety Assurance James A. FitzPatrick Nuclear Power Plant Entergy Nuclear Operations, Inc.
P.O. Box 110 James A. FitzPatrick Nuclear Power Plant Lycoming, NY 13093 P.O. Box 110 Lycoming, NY 13093 Mr. Kevin J. Mulligan General Manager, Plant Operations Mr. James Costedio Entergy Nuclear Operations, Inc. Manager, Regulatory Compliance James A. FitzPatrick Nuclear Power Plant Entergy Nuclear Operations, Inc.
P.O. Box 110 James A. FitzPatrick Nuclear Power Plant Lycoming, NY 13093 P.O. Box 110 Lycoming, NY 13093 Mr. Oscar Limpias Vice President Engineering Assistant General Counsel Entergy Nuclear Operations, Inc. Entergy Nuclear Operations, Inc.
440 Hamilton Avenue 440 Hamilton Avenue White Plains, NY 10601 White Plains, NY 10601 Mr. Christopher Schwartz Mr. Charles Donaldson, Esquire Vice President, Operations Support Assistant Attorney General Entergy Nuclear Operations, Inc. New York Department of Law 440 Hamilton Avenue 120 Broadway White Plains, NY 10601 New York, NY 10271 Mr. John F. McCann Regional Administrator, Region I Director, Licensing U.S. Nuclear Regulatory Commission Entergy Nuclear Operations, Inc. 475 Allendale Road 440 Hamilton Avenue King of Prussia, PA 19406 White Plains, NY 10601 Mr. Steven Lyman Resident Inspector's Office Oswego County Administrator James A. FitzPatrick Nuclear Power Plant 46 East Bridge Street U. S. Nuclear Regulatory Commission Oswego, NY 13126 P.O. Box 136 Lycoming, NY 13093
Mr. Peter R. Smith, President New York State Energy, Research, and Development Authority 17 Columbia Circle Albany, NY 12203-6399 Mr. Paul Eddy New York State Dept. of Public Service 3 Empire State Plaza Albany, NY 12223-1350 Supervisor Town of Scriba Route 8, Box 382 Oswego, NY 13126 Mr. James H. Sniezek BWR SRC Consultant 5486 Nithsdale Drive Salisbury, MD 21801-2490 Mr. Michael D. Lyster BWR SRC Consultant 5931 Barclay Lane Naples, FL 34110-7306 Mr. Garrett D. Edwards 814 Waverly Road Kennett Square, PA 19348 Mr. Rick Plasse Project Manager, License Renewal Entergy Nuclear Operations, Inc.
James A. FitzPatrick Nuclear Power Plant P.O. Box 110 Lycoming, NY 13093 Mr. James Ross Nuclear Energy Institute 1776 I Street, NW, Suite 400 Washington, DC 20006-3708