Category:INSPECTION REPORT
MONTHYEARIR 05000313/19990121999-09-0101 September 1999 Insp Repts 50-313/99-12 & 50-368/99-12 on 990711-0821.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000313/19990111999-08-12012 August 1999 Insp Repts 50-313/99-11 & 50-368/99-11 on 990719-23.No Violations Noted.Major Areas Inspected:Licensee Requalification Program IR 05000313/19990081999-07-21021 July 1999 Insp Repts 50-313/99-08 & 50-368/99-08 on 990530-0710.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19990051999-06-10010 June 1999 Insp Repts 50-313/99-05 & 50-368/99-05 on 990411-0529.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000313/19990061999-06-0808 June 1999 Insp Repts 50-313/99-06 & 50-368/99-06 on 990524-28. Violations Identified & Being Treated as Noncited Violation. Major Areas Inspected:Radiological Environ Monitoring Program IR 05000313/19980211999-05-24024 May 1999 Insp Repts 50-313/98-21 & 50-368/98-01 on 981116-990406.One Violation Occurred & Being Treated as non-cited Violation. Major Areas Inspected:Review of Licensee Implementation of post-fire Alternative Shutdown Requirements ML20206S4881999-05-14014 May 1999 Insp Repts 50-313/99-07 & 50-368/99-07 on 990426-30.No Violations Noted.Major Areas Inspected:Access Authorization, Alarm Stations,Communications,Protected Area Access Control of Personnel,Packages & Vehicles & Assessment Aids IR 05000313/19990041999-05-10010 May 1999 Insp Repts 50-313/99-04 & 50-368/99-04 on 990228-0410. Non-cited Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000313/19990031999-04-0909 April 1999 Insp Repts 50-313/99-03 & 50-368/99-03 on 990202-17.No Violations Noted.Major Areas Inspected:Operations IR 05000313/19990011999-04-0202 April 1999 Insp Repts 50-313/99-01 & 50-368/99-01 on 990117-0227.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19980101999-02-0909 February 1999 Insp Repts 50-313/98-10 & 50-368/98-10 on 981206-990116.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000313/19990021999-01-25025 January 1999 Insp Repts 50-313/99-02 & 50-368/99-02 on 990111-15.No Violations Noted.Major Areas Inspected:Exposure Controls, Controls of Radioactive Matl & Contamination,Surveying & Monitoring & Program to Maintain Occupational Exposure IR 05000313/19980091998-12-21021 December 1998 Insp Repts 50-313/98-09 & 50-368/98-09 on 981025-1205.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19980081998-11-19019 November 1998 Insp Repts 50-313/98-08 & 50-368/98-08 on 980913-1024. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19980191998-11-11011 November 1998 Insp Repts 50-313/98-19 & 50-368/98-19 on 981019-22.No Violations Noted.Major Areas Inspected:Exposure Controls, Control of Radioactive Matls & Contamination,Surveying & Monitoring & QA Oversight of Radiation Protection Program IR 05000313/19980201998-10-27027 October 1998 Insp Repts 50-313/98-20 & 50-368/98-20 on 981019-22.No Violations Noted.Major Areas Inspected:Operational Status of Licensee Emergency Preparedness Program IR 05000313/19980071998-10-15015 October 1998 Corrected Pages to Insp Repts 50-313/98-07 & 50-368/98-07 on 980925.Typo Was Identified in Numbering of Insp Followup Sys Closed Items ML20153H2461998-09-25025 September 1998 Insp Repts 50-313/98-07 & 50-368/98-07 on 980802-0912.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000313/19980161998-09-15015 September 1998 Insp Repts 50-313/98-16 & 50-368/98-16 on 980831-0904.No Violations Noted.Major Areas Inspected:Testing & Maintenance,Protected Area Barrier & Detection Aids, Compensatory Measures & Security Sys Power Supply IR 05000313/19980111998-09-0303 September 1998 Insp Repts 50-313/98-11 & 50-368/98-11 Has Been Canceled.No Other Rept Will Be Issued IR 05000313/19980151998-09-0202 September 1998 Insp Repts 50-313/98-15 & 50-368/98-15 on 980818-21.No Violations Noted.Major Areas Inspected:Licensee Performance & Capabilities During full-scale,biennial Exercise of Emergency Plan & Implementing Procedures IR 05000313/19980061998-08-18018 August 1998 Insp Repts 50-313/98-06 & 50-368/98-06 on 980621-0801. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000313/19980051998-07-16016 July 1998 Insp Repts 50-313/98-05 & 50-368/98-05 on 980510-0620.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000313/19980041998-06-0404 June 1998 Insp Repts 50-313/98-04 & 50-368/98-04 on 980329-0509. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20216D2521998-05-11011 May 1998 Errata to Insp Repts 50-313/98-12 & 50-368/98-12 ML20247K0301998-05-0808 May 1998 Insp Repts 50-313/98-14 & 50-368/98-14 on 980427-0501. Violations Noted.Major Areas Inspected:Access Authorization, Alarm Stations,Communications,Access Control of Personnel & Packages & Vehicles ML20217A9351998-04-17017 April 1998 Insp Repts 50-313/98-03 & 50-368/98-03 on 980215-0328. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000313/19980131998-04-14014 April 1998 Insp Repts 50-313/98-13 & 50-368/98-13 on 980330-0403. Violations Noted.Major Areas Inspected:Review of Radiation Protection Program Focussing on Unit 1 Refueling Outage Activities ML20217N3021998-04-0202 April 1998 Insp Repts 50-313/98-12 & 50-368/98-12 on 980302-11. Violations Noted.Major Areas Inspected:Maint & Engineering ML20216B8751998-03-10010 March 1998 Insp Repts 50-313/98-02 & 50-368/98-02 on 980104-0214. Violation Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20202E3401998-02-0606 February 1998 Insp Repts 50-313/97-21 & 50-368/97-21 on 971027-31 & 1110- 14.Violations Noted.Major Areas Inspected:Engineering & Plant Support.Nrc Identified Fire Barrier Deficiency & Licensee Took Promp Compensatory Actions as Required IR 05000313/19970081998-01-23023 January 1998 Insp Repts 50-313/97-08 & 50-368/97-08 on 971123-980103.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19970201997-12-17017 December 1997 Insp Repts 50-313/97-20 & 50-368/97-20 on 971117-20.No Violations Noted.Major Areas Inspected:Plant Support, Radiological Protection & Chemistry Controls & Status of Radiological Protection & Chemistry Facilities & Equipment IR 05000313/19970071997-12-12012 December 1997 Insp Repts 50-313/97-07 & 50-368/97-07 on 971011-1122.No Violations Noted.Major Areas Inspected:Operations, Maintenance & Plant Support IR 05000313/19970181997-12-0606 December 1997 Insp Repts 50-313/97-18 & 50-368/97-18 on 971020-1107. Violations Noted.Major Areas Inspected:Operations,Maint & Plant Support IR 05000313/19970191997-11-28028 November 1997 Insp Repts 50-313/97-19 & 50-368/97-19 on 971103-06. Violations Noted.Major Areas Inspected:Exposure Controls, Radioactive Matl & Contamination,Surveying,Monitoring & Quality Assurance in Radiation Protection Activities IR 05000313/19970221997-11-28028 November 1997 Insp Repts 50-313/97-22 & 50-368/97-22 on 971117-22.No Violations Noted.Major Areas Inspected:Protected & Vital Area Barriers & Detention Aids,Security Sys Power Supply, Event Logs,Training & Qualifications IR 05000313/19970061997-11-0606 November 1997 Insp Repts 50-313/97-06 & 50-368/97-06 on 970831-1011.No Violations Noted.Major Areas Inspected:Operation,Maint & Plant Support IR 05000313/19970171997-09-17017 September 1997 Insp Repts 50-313/97-17 & 50-368/97-17 on 970825-28. Violations Noted.Major Areas Inspected:Routine,Announced Insp of Liquid & Gaseous Radioactive Effluent Waste Mgt Program Including Organization & Mgt Controls IR 05000313/19970051997-09-16016 September 1997 Insp Repts 50-313/97-05 & 50-368/97-05 on 970720-0830. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000313/19970141997-09-12012 September 1997 Insp Repts 50-313/97-14 & 50-368/97-14 on 970527-0807.No Violations Noted.Major Areas Inspected:Maint & Engineering IR 05000313/19970111997-08-15015 August 1997 Insp Repts 50-313/97-11 & 50-368/97-11 on 970728-0801.No Violations Noted.Major Areas Inspected:Licensee Requalification Program IR 05000313/19970161997-08-0101 August 1997 Insp Repts 50-313/97-16 & 50-368/97-16 on 970721-25.No Violations Noted.Major Areas Inspected:Records & Repts, Testing & Maint,Assessment Aids,Alarm Stations, Communications,Security Plans & Procedures ML20151J9231997-07-30030 July 1997 Insp Repts 50-313/97-04 & 50-368/97-04 on 970608-0719. Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000313/19972011997-07-24024 July 1997 Insp Rept 50-313/97-201 on 970210-0314.Violations Noted. Major Areas Inspected:Design Inspection of EFW & Decay Heat/Low Pressure Injection System ML20148T0091997-07-0101 July 1997 Insp Repts 50-313/97-03 & 50-368/97-03 on 970427-0607. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20148P5921997-06-28028 June 1997 Insp Repts 50-313/97-13 & 50-368/97-13 on 970512-0605. Violations Noted.Major Areas Inspected:Maintenance & Engineering ML20148P5851997-06-28028 June 1997 Insp Repts 50-313/97-15 & 50-368/97-15 on 970602-06. Violations Noted.Major Areas Inspected:Plant Support Re Controlled Access Area IR 05000313/19960281997-05-21021 May 1997 Insp Repts 50-313/96-28 & 50-368/96-28 on 961125-1213.No Violations Noted.Major Areas Inspected:Operations,Maint & Engineering ML20141G7451997-05-19019 May 1997 Insp Repts 50-313/97-02 & 50-368/97-02 on 970316-0426. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint, & Plant Support 1999-09-01
[Table view] Category:NRC-GENERATED
MONTHYEARIR 05000313/19990121999-09-0101 September 1999 Insp Repts 50-313/99-12 & 50-368/99-12 on 990711-0821.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000313/19990111999-08-12012 August 1999 Insp Repts 50-313/99-11 & 50-368/99-11 on 990719-23.No Violations Noted.Major Areas Inspected:Licensee Requalification Program IR 05000313/19990081999-07-21021 July 1999 Insp Repts 50-313/99-08 & 50-368/99-08 on 990530-0710.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19990051999-06-10010 June 1999 Insp Repts 50-313/99-05 & 50-368/99-05 on 990411-0529.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000313/19990061999-06-0808 June 1999 Insp Repts 50-313/99-06 & 50-368/99-06 on 990524-28. Violations Identified & Being Treated as Noncited Violation. Major Areas Inspected:Radiological Environ Monitoring Program IR 05000313/19980211999-05-24024 May 1999 Insp Repts 50-313/98-21 & 50-368/98-01 on 981116-990406.One Violation Occurred & Being Treated as non-cited Violation. Major Areas Inspected:Review of Licensee Implementation of post-fire Alternative Shutdown Requirements ML20206S4881999-05-14014 May 1999 Insp Repts 50-313/99-07 & 50-368/99-07 on 990426-30.No Violations Noted.Major Areas Inspected:Access Authorization, Alarm Stations,Communications,Protected Area Access Control of Personnel,Packages & Vehicles & Assessment Aids IR 05000313/19990041999-05-10010 May 1999 Insp Repts 50-313/99-04 & 50-368/99-04 on 990228-0410. Non-cited Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000313/19990031999-04-0909 April 1999 Insp Repts 50-313/99-03 & 50-368/99-03 on 990202-17.No Violations Noted.Major Areas Inspected:Operations IR 05000313/19990011999-04-0202 April 1999 Insp Repts 50-313/99-01 & 50-368/99-01 on 990117-0227.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19980101999-02-0909 February 1999 Insp Repts 50-313/98-10 & 50-368/98-10 on 981206-990116.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000313/19990021999-01-25025 January 1999 Insp Repts 50-313/99-02 & 50-368/99-02 on 990111-15.No Violations Noted.Major Areas Inspected:Exposure Controls, Controls of Radioactive Matl & Contamination,Surveying & Monitoring & Program to Maintain Occupational Exposure IR 05000313/19980091998-12-21021 December 1998 Insp Repts 50-313/98-09 & 50-368/98-09 on 981025-1205.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19980081998-11-19019 November 1998 Insp Repts 50-313/98-08 & 50-368/98-08 on 980913-1024. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19980191998-11-11011 November 1998 Insp Repts 50-313/98-19 & 50-368/98-19 on 981019-22.No Violations Noted.Major Areas Inspected:Exposure Controls, Control of Radioactive Matls & Contamination,Surveying & Monitoring & QA Oversight of Radiation Protection Program IR 05000313/19980201998-10-27027 October 1998 Insp Repts 50-313/98-20 & 50-368/98-20 on 981019-22.No Violations Noted.Major Areas Inspected:Operational Status of Licensee Emergency Preparedness Program IR 05000313/19980071998-10-15015 October 1998 Corrected Pages to Insp Repts 50-313/98-07 & 50-368/98-07 on 980925.Typo Was Identified in Numbering of Insp Followup Sys Closed Items ML20153H2461998-09-25025 September 1998 Insp Repts 50-313/98-07 & 50-368/98-07 on 980802-0912.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000313/19980161998-09-15015 September 1998 Insp Repts 50-313/98-16 & 50-368/98-16 on 980831-0904.No Violations Noted.Major Areas Inspected:Testing & Maintenance,Protected Area Barrier & Detection Aids, Compensatory Measures & Security Sys Power Supply IR 05000313/19980111998-09-0303 September 1998 Insp Repts 50-313/98-11 & 50-368/98-11 Has Been Canceled.No Other Rept Will Be Issued IR 05000313/19980151998-09-0202 September 1998 Insp Repts 50-313/98-15 & 50-368/98-15 on 980818-21.No Violations Noted.Major Areas Inspected:Licensee Performance & Capabilities During full-scale,biennial Exercise of Emergency Plan & Implementing Procedures IR 05000313/19980061998-08-18018 August 1998 Insp Repts 50-313/98-06 & 50-368/98-06 on 980621-0801. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000313/19980051998-07-16016 July 1998 Insp Repts 50-313/98-05 & 50-368/98-05 on 980510-0620.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000313/19980041998-06-0404 June 1998 Insp Repts 50-313/98-04 & 50-368/98-04 on 980329-0509. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20216D2521998-05-11011 May 1998 Errata to Insp Repts 50-313/98-12 & 50-368/98-12 ML20247K0301998-05-0808 May 1998 Insp Repts 50-313/98-14 & 50-368/98-14 on 980427-0501. Violations Noted.Major Areas Inspected:Access Authorization, Alarm Stations,Communications,Access Control of Personnel & Packages & Vehicles ML20217A9351998-04-17017 April 1998 Insp Repts 50-313/98-03 & 50-368/98-03 on 980215-0328. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000313/19980131998-04-14014 April 1998 Insp Repts 50-313/98-13 & 50-368/98-13 on 980330-0403. Violations Noted.Major Areas Inspected:Review of Radiation Protection Program Focussing on Unit 1 Refueling Outage Activities ML20217N3021998-04-0202 April 1998 Insp Repts 50-313/98-12 & 50-368/98-12 on 980302-11. Violations Noted.Major Areas Inspected:Maint & Engineering ML20216B8751998-03-10010 March 1998 Insp Repts 50-313/98-02 & 50-368/98-02 on 980104-0214. Violation Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20202E3401998-02-0606 February 1998 Insp Repts 50-313/97-21 & 50-368/97-21 on 971027-31 & 1110- 14.Violations Noted.Major Areas Inspected:Engineering & Plant Support.Nrc Identified Fire Barrier Deficiency & Licensee Took Promp Compensatory Actions as Required IR 05000313/19970081998-01-23023 January 1998 Insp Repts 50-313/97-08 & 50-368/97-08 on 971123-980103.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19970201997-12-17017 December 1997 Insp Repts 50-313/97-20 & 50-368/97-20 on 971117-20.No Violations Noted.Major Areas Inspected:Plant Support, Radiological Protection & Chemistry Controls & Status of Radiological Protection & Chemistry Facilities & Equipment IR 05000313/19970071997-12-12012 December 1997 Insp Repts 50-313/97-07 & 50-368/97-07 on 971011-1122.No Violations Noted.Major Areas Inspected:Operations, Maintenance & Plant Support IR 05000313/19970181997-12-0606 December 1997 Insp Repts 50-313/97-18 & 50-368/97-18 on 971020-1107. Violations Noted.Major Areas Inspected:Operations,Maint & Plant Support IR 05000313/19970191997-11-28028 November 1997 Insp Repts 50-313/97-19 & 50-368/97-19 on 971103-06. Violations Noted.Major Areas Inspected:Exposure Controls, Radioactive Matl & Contamination,Surveying,Monitoring & Quality Assurance in Radiation Protection Activities IR 05000313/19970221997-11-28028 November 1997 Insp Repts 50-313/97-22 & 50-368/97-22 on 971117-22.No Violations Noted.Major Areas Inspected:Protected & Vital Area Barriers & Detention Aids,Security Sys Power Supply, Event Logs,Training & Qualifications IR 05000313/19970061997-11-0606 November 1997 Insp Repts 50-313/97-06 & 50-368/97-06 on 970831-1011.No Violations Noted.Major Areas Inspected:Operation,Maint & Plant Support IR 05000313/19970171997-09-17017 September 1997 Insp Repts 50-313/97-17 & 50-368/97-17 on 970825-28. Violations Noted.Major Areas Inspected:Routine,Announced Insp of Liquid & Gaseous Radioactive Effluent Waste Mgt Program Including Organization & Mgt Controls IR 05000313/19970051997-09-16016 September 1997 Insp Repts 50-313/97-05 & 50-368/97-05 on 970720-0830. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000313/19970141997-09-12012 September 1997 Insp Repts 50-313/97-14 & 50-368/97-14 on 970527-0807.No Violations Noted.Major Areas Inspected:Maint & Engineering IR 05000313/19970111997-08-15015 August 1997 Insp Repts 50-313/97-11 & 50-368/97-11 on 970728-0801.No Violations Noted.Major Areas Inspected:Licensee Requalification Program IR 05000313/19970161997-08-0101 August 1997 Insp Repts 50-313/97-16 & 50-368/97-16 on 970721-25.No Violations Noted.Major Areas Inspected:Records & Repts, Testing & Maint,Assessment Aids,Alarm Stations, Communications,Security Plans & Procedures ML20151J9231997-07-30030 July 1997 Insp Repts 50-313/97-04 & 50-368/97-04 on 970608-0719. Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000313/19972011997-07-24024 July 1997 Insp Rept 50-313/97-201 on 970210-0314.Violations Noted. Major Areas Inspected:Design Inspection of EFW & Decay Heat/Low Pressure Injection System ML20148T0091997-07-0101 July 1997 Insp Repts 50-313/97-03 & 50-368/97-03 on 970427-0607. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20148P5921997-06-28028 June 1997 Insp Repts 50-313/97-13 & 50-368/97-13 on 970512-0605. Violations Noted.Major Areas Inspected:Maintenance & Engineering ML20148P5851997-06-28028 June 1997 Insp Repts 50-313/97-15 & 50-368/97-15 on 970602-06. Violations Noted.Major Areas Inspected:Plant Support Re Controlled Access Area IR 05000313/19960281997-05-21021 May 1997 Insp Repts 50-313/96-28 & 50-368/96-28 on 961125-1213.No Violations Noted.Major Areas Inspected:Operations,Maint & Engineering ML20141G7451997-05-19019 May 1997 Insp Repts 50-313/97-02 & 50-368/97-02 on 970316-0426. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint, & Plant Support 1999-09-01
[Table view] Category:INSPECTION REPORT
MONTHYEARIR 05000313/19990121999-09-0101 September 1999 Insp Repts 50-313/99-12 & 50-368/99-12 on 990711-0821.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000313/19990111999-08-12012 August 1999 Insp Repts 50-313/99-11 & 50-368/99-11 on 990719-23.No Violations Noted.Major Areas Inspected:Licensee Requalification Program IR 05000313/19990081999-07-21021 July 1999 Insp Repts 50-313/99-08 & 50-368/99-08 on 990530-0710.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19990051999-06-10010 June 1999 Insp Repts 50-313/99-05 & 50-368/99-05 on 990411-0529.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000313/19990061999-06-0808 June 1999 Insp Repts 50-313/99-06 & 50-368/99-06 on 990524-28. Violations Identified & Being Treated as Noncited Violation. Major Areas Inspected:Radiological Environ Monitoring Program IR 05000313/19980211999-05-24024 May 1999 Insp Repts 50-313/98-21 & 50-368/98-01 on 981116-990406.One Violation Occurred & Being Treated as non-cited Violation. Major Areas Inspected:Review of Licensee Implementation of post-fire Alternative Shutdown Requirements ML20206S4881999-05-14014 May 1999 Insp Repts 50-313/99-07 & 50-368/99-07 on 990426-30.No Violations Noted.Major Areas Inspected:Access Authorization, Alarm Stations,Communications,Protected Area Access Control of Personnel,Packages & Vehicles & Assessment Aids IR 05000313/19990041999-05-10010 May 1999 Insp Repts 50-313/99-04 & 50-368/99-04 on 990228-0410. Non-cited Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000313/19990031999-04-0909 April 1999 Insp Repts 50-313/99-03 & 50-368/99-03 on 990202-17.No Violations Noted.Major Areas Inspected:Operations IR 05000313/19990011999-04-0202 April 1999 Insp Repts 50-313/99-01 & 50-368/99-01 on 990117-0227.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19980101999-02-0909 February 1999 Insp Repts 50-313/98-10 & 50-368/98-10 on 981206-990116.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000313/19990021999-01-25025 January 1999 Insp Repts 50-313/99-02 & 50-368/99-02 on 990111-15.No Violations Noted.Major Areas Inspected:Exposure Controls, Controls of Radioactive Matl & Contamination,Surveying & Monitoring & Program to Maintain Occupational Exposure IR 05000313/19980091998-12-21021 December 1998 Insp Repts 50-313/98-09 & 50-368/98-09 on 981025-1205.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19980081998-11-19019 November 1998 Insp Repts 50-313/98-08 & 50-368/98-08 on 980913-1024. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19980191998-11-11011 November 1998 Insp Repts 50-313/98-19 & 50-368/98-19 on 981019-22.No Violations Noted.Major Areas Inspected:Exposure Controls, Control of Radioactive Matls & Contamination,Surveying & Monitoring & QA Oversight of Radiation Protection Program IR 05000313/19980201998-10-27027 October 1998 Insp Repts 50-313/98-20 & 50-368/98-20 on 981019-22.No Violations Noted.Major Areas Inspected:Operational Status of Licensee Emergency Preparedness Program IR 05000313/19980071998-10-15015 October 1998 Corrected Pages to Insp Repts 50-313/98-07 & 50-368/98-07 on 980925.Typo Was Identified in Numbering of Insp Followup Sys Closed Items ML20153H2461998-09-25025 September 1998 Insp Repts 50-313/98-07 & 50-368/98-07 on 980802-0912.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000313/19980161998-09-15015 September 1998 Insp Repts 50-313/98-16 & 50-368/98-16 on 980831-0904.No Violations Noted.Major Areas Inspected:Testing & Maintenance,Protected Area Barrier & Detection Aids, Compensatory Measures & Security Sys Power Supply IR 05000313/19980111998-09-0303 September 1998 Insp Repts 50-313/98-11 & 50-368/98-11 Has Been Canceled.No Other Rept Will Be Issued IR 05000313/19980151998-09-0202 September 1998 Insp Repts 50-313/98-15 & 50-368/98-15 on 980818-21.No Violations Noted.Major Areas Inspected:Licensee Performance & Capabilities During full-scale,biennial Exercise of Emergency Plan & Implementing Procedures IR 05000313/19980061998-08-18018 August 1998 Insp Repts 50-313/98-06 & 50-368/98-06 on 980621-0801. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000313/19980051998-07-16016 July 1998 Insp Repts 50-313/98-05 & 50-368/98-05 on 980510-0620.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000313/19980041998-06-0404 June 1998 Insp Repts 50-313/98-04 & 50-368/98-04 on 980329-0509. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20216D2521998-05-11011 May 1998 Errata to Insp Repts 50-313/98-12 & 50-368/98-12 ML20247K0301998-05-0808 May 1998 Insp Repts 50-313/98-14 & 50-368/98-14 on 980427-0501. Violations Noted.Major Areas Inspected:Access Authorization, Alarm Stations,Communications,Access Control of Personnel & Packages & Vehicles ML20217A9351998-04-17017 April 1998 Insp Repts 50-313/98-03 & 50-368/98-03 on 980215-0328. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000313/19980131998-04-14014 April 1998 Insp Repts 50-313/98-13 & 50-368/98-13 on 980330-0403. Violations Noted.Major Areas Inspected:Review of Radiation Protection Program Focussing on Unit 1 Refueling Outage Activities ML20217N3021998-04-0202 April 1998 Insp Repts 50-313/98-12 & 50-368/98-12 on 980302-11. Violations Noted.Major Areas Inspected:Maint & Engineering ML20216B8751998-03-10010 March 1998 Insp Repts 50-313/98-02 & 50-368/98-02 on 980104-0214. Violation Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20202E3401998-02-0606 February 1998 Insp Repts 50-313/97-21 & 50-368/97-21 on 971027-31 & 1110- 14.Violations Noted.Major Areas Inspected:Engineering & Plant Support.Nrc Identified Fire Barrier Deficiency & Licensee Took Promp Compensatory Actions as Required IR 05000313/19970081998-01-23023 January 1998 Insp Repts 50-313/97-08 & 50-368/97-08 on 971123-980103.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19970201997-12-17017 December 1997 Insp Repts 50-313/97-20 & 50-368/97-20 on 971117-20.No Violations Noted.Major Areas Inspected:Plant Support, Radiological Protection & Chemistry Controls & Status of Radiological Protection & Chemistry Facilities & Equipment IR 05000313/19970071997-12-12012 December 1997 Insp Repts 50-313/97-07 & 50-368/97-07 on 971011-1122.No Violations Noted.Major Areas Inspected:Operations, Maintenance & Plant Support IR 05000313/19970181997-12-0606 December 1997 Insp Repts 50-313/97-18 & 50-368/97-18 on 971020-1107. Violations Noted.Major Areas Inspected:Operations,Maint & Plant Support IR 05000313/19970191997-11-28028 November 1997 Insp Repts 50-313/97-19 & 50-368/97-19 on 971103-06. Violations Noted.Major Areas Inspected:Exposure Controls, Radioactive Matl & Contamination,Surveying,Monitoring & Quality Assurance in Radiation Protection Activities IR 05000313/19970221997-11-28028 November 1997 Insp Repts 50-313/97-22 & 50-368/97-22 on 971117-22.No Violations Noted.Major Areas Inspected:Protected & Vital Area Barriers & Detention Aids,Security Sys Power Supply, Event Logs,Training & Qualifications IR 05000313/19970061997-11-0606 November 1997 Insp Repts 50-313/97-06 & 50-368/97-06 on 970831-1011.No Violations Noted.Major Areas Inspected:Operation,Maint & Plant Support IR 05000313/19970171997-09-17017 September 1997 Insp Repts 50-313/97-17 & 50-368/97-17 on 970825-28. Violations Noted.Major Areas Inspected:Routine,Announced Insp of Liquid & Gaseous Radioactive Effluent Waste Mgt Program Including Organization & Mgt Controls IR 05000313/19970051997-09-16016 September 1997 Insp Repts 50-313/97-05 & 50-368/97-05 on 970720-0830. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000313/19970141997-09-12012 September 1997 Insp Repts 50-313/97-14 & 50-368/97-14 on 970527-0807.No Violations Noted.Major Areas Inspected:Maint & Engineering IR 05000313/19970111997-08-15015 August 1997 Insp Repts 50-313/97-11 & 50-368/97-11 on 970728-0801.No Violations Noted.Major Areas Inspected:Licensee Requalification Program IR 05000313/19970161997-08-0101 August 1997 Insp Repts 50-313/97-16 & 50-368/97-16 on 970721-25.No Violations Noted.Major Areas Inspected:Records & Repts, Testing & Maint,Assessment Aids,Alarm Stations, Communications,Security Plans & Procedures ML20151J9231997-07-30030 July 1997 Insp Repts 50-313/97-04 & 50-368/97-04 on 970608-0719. Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000313/19972011997-07-24024 July 1997 Insp Rept 50-313/97-201 on 970210-0314.Violations Noted. Major Areas Inspected:Design Inspection of EFW & Decay Heat/Low Pressure Injection System ML20148T0091997-07-0101 July 1997 Insp Repts 50-313/97-03 & 50-368/97-03 on 970427-0607. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20148P5921997-06-28028 June 1997 Insp Repts 50-313/97-13 & 50-368/97-13 on 970512-0605. Violations Noted.Major Areas Inspected:Maintenance & Engineering ML20148P5851997-06-28028 June 1997 Insp Repts 50-313/97-15 & 50-368/97-15 on 970602-06. Violations Noted.Major Areas Inspected:Plant Support Re Controlled Access Area IR 05000313/19960281997-05-21021 May 1997 Insp Repts 50-313/96-28 & 50-368/96-28 on 961125-1213.No Violations Noted.Major Areas Inspected:Operations,Maint & Engineering ML20141G7451997-05-19019 May 1997 Insp Repts 50-313/97-02 & 50-368/97-02 on 970316-0426. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint, & Plant Support 1999-09-01
[Table view] Category:UTILITY
MONTHYEARIR 05000313/19900301990-11-0707 November 1990 Insp Repts 50-313/90-30 & 50-368/90-30 on 900905-1016. Violations Noted.Major Areas Inspected:Onsite Event Followup,Operational Safety Verification,Mod Installation, Surveillance,Maint & Review of Previous Insp Findings ML20058G8541990-11-0505 November 1990 Insp Repts 50-313/90-32 & 50-368/90-32 on 900924-28.Major Areas Inspected:Select Portions of Occupational Radiation Protection,Transportation & Solid Radwaste Programs IR 05000313/19900311990-10-31031 October 1990 Insp Repts 50-313/90-31 & 50-368/90-31 on 901001-04.No Violations or Deviations Noted.Major Area Inspected:Training & Qualification Effectiveness IR 05000313/19900371990-10-30030 October 1990 Insp Repts 50-313/90-37 & 50-368/90-37 on 901015-19.No Violations or Deviations Noted.Major Areas Inspected: Verification of Isolation Component Exemptions IR 05000313/19900401990-10-29029 October 1990 Insp Repts 50-313/90-40 & 50-368/90-40 on 901015-19.No Violations or Deviations Noted.Areas Inspected:Inservice Insp Work Activities & Insp of Action on Previously Identified Insp Finding ML20058A5251990-10-15015 October 1990 Insp Repts 50-313/90-38 & 50-368/90-38 on 901001-05.No Violations Noted.Major Areas Inspected:Followup of Unresolved Issue Identified by Operational Safety Team Insp Re Verification That Control Ventilation Sys Meets Design IR 05000313/19900281990-09-12012 September 1990 Insp Rept 50-313/90-28 & 50-368/90-28 on 900827-31.No Violations or Deviations Noted.Major Areas inspected:post- Fire Safe Shutdown Capability Reverification & Assessment of Fire Protection/Prevention Programs IR 05000313/19900271990-08-30030 August 1990 Insp Repts 50-313/90-27 & 50-368/90-27 on 900813-17.No Violations Noted.Major Areas Inspected:Review of Records Program,Document Control Program & Design Changes & Mods Program IR 05000313/19900231990-08-23023 August 1990 Insp Repts 50-313/90-23 & 50-368/90-23 on 900716-20.No Violations or Deviations Noted.Major Areas Inspected:Liquid & Gaseous Waste Mgt & Water Chemistry Programs IR 05000313/19900261990-08-13013 August 1990 Insp Repts 50-313/90-26 & 50-368/90-26 on 900730-0803.No Violations or Deviations Noted.Major Areas Inspected: Procurement,Receipt,Storage & Handling of Equipment & Matls IR 05000313/19900191990-08-0707 August 1990 Insp Repts 50-313/90-19 & 50-368/90-19 on 900601-0715. Violations Noted.Major Areas Inspected:Onsite Followup of Events,Operational Safety Verification,Surveillance,Maint & Design Changes IR 05000313/19900221990-07-19019 July 1990 Cancelled Insp Repts 50-313/90-22 & 50-368/90-22 IR 05000313/19900181990-06-28028 June 1990 Insp Repts 50-313/90-18 & 50-368/90-18 on 900521-25.No Violations or Deviations Noted.Major Areas Inspected: Operational Status of Emergency Preparedness Program, Including Changes to Emergency Plan & EPIP IR 05000313/19900101990-06-21021 June 1990 Insp Repts 50-313/90-10 & 50-368/90-10 on 900514-0601.No Violations or Deviations Noted.Major Areas Inspected: Licensee Engineering & Technical Support Capabilities Re Svc Water Sys IR 05000313/19890331989-09-29029 September 1989 Partially Withheld Insp Repts 50-313/89-33 & 50-368/89-33 on 890828-0901 (Ref 10CFR73.21).Violations Noted.Major Areas Inspected:Physical Security Program,Including Protected Area Physical Barriers & Assessment Aids & Testing & Maint IR 05000313/19890311989-09-0808 September 1989 Canceled Insps 50-313/89-31 & 50-368/89-31 IR 05000313/19890301989-09-0606 September 1989 Insp Repts 50-313/89-30 & 50-368/89-30 on 890701-0815. Violation Noted.Major Areas Inspected:Plant Status,Followup of Events,Followup on Previously Identified Items, Operational Safety Verification,Surveillance & Maint IR 05000313/19890291989-07-28028 July 1989 Insp Repts 50-313/89-29 & 50-368/89-29 on 890626-29.No Violations or Deviations Noted.Major Areas Inspected: Operational Status of Emergency Preparedness Program, Including Changes to Emergency Plan & Facilities IR 05000313/19890281989-07-21021 July 1989 Insp Repts 50-313/89-28 & 50-368/89-28 on 890601-30. Violations Noted.Major Areas Inspected:Plant Status,Followup of Events,Operational Safety Verification,Followup on Previously Identified Items,Maint & Surveillance IR 05000313/19890271989-07-0707 July 1989 Partially Withheld Safeguards Insp Repts 50-313/89-27 & 50-368/89-27 on 890605-09 (Ref 10CFR73.21).No Violations or Deviations Noted.Major Areas Inspected:Physical Security Program Including Mgt Support & Security Program Plan ML20246C8741989-07-0606 July 1989 Insp Repts 50-313/89-23 & 50-368/89-23 on 890605-14.No Violations Noted.Major Areas Inspected:Licensee Actions to Prevent & Respond to Loss of Dhr,Per Generic Ltr 88-17 IR 05000313/19890261989-06-21021 June 1989 Insp Repts 50-313/89-26 & 50-368/89-26 on 890605-09. Deviation Noted.Major Areas Inspected:Tech Spec Required Calibr Program & Preventive Maint Program Re Calibr of Plant Instrumentation for Components Not Addressed in Tech Specs ML20245D7581989-06-15015 June 1989 Insp Repts 50-313/89-18 & 50-368/89-18 on 890416-0531. Violation Noted.Major Areas Inspected:Plant Status,Followup on Previously Identified Items,Followup of Events, Operational Safety Verification & Testing of Mods ML20245A1371989-06-12012 June 1989 Insp Repts 50-313/89-24 & 50-368/89-24 on 890515-19.No Violations Noted.Major Areas Inspected:Radiation Protection Program as Set Forth in Core Insp Program ML20244C2021989-06-0707 June 1989 Partially Withheld Insp Repts 50-313/89-20 & 50-368/89-20 on 890501-05 (Ref 10CFR73.21).Violations Noted Re Inadequate Assessment Aids & Compensatory Measures.Major Areas Inspected:Physical Security Program,Including Mgt Support IR 05000313/19890211989-06-0202 June 1989 Insp Repts 50-313/89-21 & 50-368/89-21 on 890508-12.No Violations or Deviations Noted.Major Areas Inspected: Chemistry/Radiochemistry Program & Water Chemistry & Radiochemistry Confirmatory Measurements IR 05000313/19890101989-05-15015 May 1989 Insp Repts 50-313/89-10 & 50-368/89-10 on 890301-0415. Violations Noted.Major Areas Inspected:Plant Status,Followup of Events,Followup of IE Bulletins & ATWS Rule 10CFR50.62, Operational Safety Verification & Monthly Maint Observation IR 05000313/19890171989-05-10010 May 1989 Insp Repts 50-313/89-17 & 50-368/89-17 on 890417-21.No Violations or Deviations Noted.Major Areas Inspected: Licensee Implementation of Integrated Corrective Action & Followup Actions Re Unit 2 Extraction Steam Line Break IR 05000313/19890191989-05-10010 May 1989 Informs That NRC Insp Repts 50-313/89-19 & 50-368/89-19 Cancelled & No Insp Rept Will Be Issued for Rept Numbers IR 05000313/19890251989-05-10010 May 1989 Cancels Insp Repts 50-313/89-25 & 50-368/89-25.No Insp Rept Will Be Issued for Listed Rept Numbers IR 05000313/19890141989-05-0202 May 1989 Insp Repts 50-313/89-14 & 50-368/89-14 on 890403-07. Violations Noted.Major Areas Inspected:Licensee Liquid & Gaseous Radwaste Mgt Programs IR 05000313/19890131989-04-29029 April 1989 Advises That Insps 50-313/89-13 & 50-368/89-13 Canceled IR 05000313/19890161989-04-17017 April 1989 Insp Repts 50-313/89-16 & 50-368/89-16 on 890327-31. Violations Noted.Major Areas Inspected:Previously Identified Insp Findings & self-assessment Capabilities IR 05000313/19890121989-04-13013 April 1989 Insp Repts 50-313/89-12 & 50-368/89-12 on 890314-16.No Violations or Deviations Noted.Weaknesses Noted Re Delay in Notification of State.Major Areas Inspected:Annual Exercise of Emergency Plan & Procedures IR 05000313/19890151989-04-0303 April 1989 Insp Repts 50-313/89-15 & 50-368/89-15 on 890320-24.No Violations or Deviations Noted.Major Areas Inspected:Mod Testing Program & Followup to Previous Insp Findings IR 05000313/19890041989-03-31031 March 1989 Insp Repts 50-313/89-04 & 50-368/89-04 on 890206-17 & 20-24. Violations Noted.Major Areas inspected:long-term Followup Actions Re Equipment Malfunctions Which Occurred Following Turbine/Reactor Trip on 890120 IR 05000313/19890081989-03-30030 March 1989 Insp Repts 50-313/89-08 & 50-368/89-08 on 890227-0303.No Violations or Deviations Noted.Major Areas Inspected: Inservice Testing Program for Pumps & Valves & Actions Taken Re Previously Identified Insp Findings IR 05000313/19890091989-03-30030 March 1989 Insp Repts 50-313/89-09 & 50-368/89-09 on 890307-10.No Violations or Deviations Noted.Major Areas Inspected:Action on Previous Insp Findings,Dhr Sys Pipe Supports,Hanger Damage & Emergency Diesel Geneator Exhaust Manifold Fires IR 05000313/19890111989-03-29029 March 1989 Partially Withheld Insp Repts 50-313/89-11 & 50-368/89-11 on 890227-0303 (Ref 10CFR73.21).No Violations or Deviations Noted.Major Areas Inspected:Physical Security Program, Including Mgt Support,Security Program Plan & Audits IR 05000313/19890071989-03-27027 March 1989 Insp Repts 50-313/89-07 & 50-368/89-07 on 890313-17.No Violations Noted.Major Areas Inspected:Licensee Commitments Re Actions to Prevent Low Temp Overpressure Transient Conditions & Implementation of Instrument Calibration IR 05000313/19890051989-03-24024 March 1989 Insp Repts 50-313/89-05 & 50-368/89-05 on 890201-28. Violation Noted Re Rigging from Safety Piping.Major Areas Inspected:Maint,Followup of Events,Operational Safety Verification,Surveillance & Allegation Followup IR 05000313/19890061989-03-0909 March 1989 Insp Repts 50-313/89-06 & 50-368/89-06 on 890221-24.No Violations Noted.Unresolved Items Re Radiographic Exam Procedures for Penetrameters Noted.Major Areas Inspected: Mods to Unit 1 Hpis & Repair of Unit 2 Refueling Water Tank IR 05000313/19890021989-02-27027 February 1989 Insp Repts 50-313/89-02 & 50-368/89-02 on 890101-31. Violations Noted.Major Areas Inspected:Plant Status,Followup on Previously Identified Items,Lers & Events & Operational Safety & Monthly Maint/Surveillance Observations IR 05000313/19890031989-02-15015 February 1989 Insp Repts 50-313/89-03 & 50-368/89-03 on 890124-25.Major Areas Inspected:Circumstances Following 890120 Reactor Trip Leading to Reactor Coolant Backleakage Through HPSI Check Valve Which Failed to Seat IR 05000313/19880461988-12-0202 December 1988 Informs That Insps 50-313/88-46 & 50-368/88-46 Cancelled & No Insp Repts Will Be Issued for Rept Numbers IR 05000313/19880371988-11-22022 November 1988 Insp Repts 50-313/88-37 & 50-368/88-37 on 881017-1104.No Violations or Deviations Noted.Major Areas Inspected: Licensee Capability for self-assessment & Compliance W/ Respective OL Tech Spec Requirements ML20195G9941988-11-17017 November 1988 Insp Repts 50-313/88-35 & 50-368/88-35 on 881030-1104. Violation Noted.Major Areas Inspected:Unit 1 Containment Integrated Leak Rate Test IR 05000313/19880411988-11-16016 November 1988 Insp Repts 50-313/88-41 & 50-368/88-41 on 881103-04. Violations Noted.Major Areas Inspected:Events Surrounding Apparent Overexposure of One Worker Performing Maint Work During Refueling Outage IR 05000313/19880321988-11-15015 November 1988 Insp Repts 50-313/88-32 & 50-368/88-32 on 880916-1023. Violations Noted.Major Areas Inspected:Maint,Surveillance, Operational Safety Verification,Followup on LERs & Events IR 05000313/19880331988-10-27027 October 1988 Insp Repts 50-313/88-33 & 50-368/88-33 on 881002-07.No Violations or Deviations Noted.Major Areas Inspected: Licensee Responses O 10CFR50.62 Rule on Atws.Licensee Commits to Actions to Prevent low-temp Overpressure 1990-09-12
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARIR 05000313/19990121999-09-0101 September 1999 Insp Repts 50-313/99-12 & 50-368/99-12 on 990711-0821.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000313/19990111999-08-12012 August 1999 Insp Repts 50-313/99-11 & 50-368/99-11 on 990719-23.No Violations Noted.Major Areas Inspected:Licensee Requalification Program IR 05000313/19990081999-07-21021 July 1999 Insp Repts 50-313/99-08 & 50-368/99-08 on 990530-0710.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support ML20196D4851999-06-21021 June 1999 Partially Deleted Notice of Violation from Insp on 990204. Violation Noted.Ed Mccormic,Individual Licensed Operator, Violated 10CFR50.53(j) by Use of Illegal Drug (Marijuana) as Evidence by Confirmed Positive Test for Urine on 981222 IR 05000313/19990051999-06-10010 June 1999 Insp Repts 50-313/99-05 & 50-368/99-05 on 990411-0529.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000313/19990061999-06-0808 June 1999 Insp Repts 50-313/99-06 & 50-368/99-06 on 990524-28. Violations Identified & Being Treated as Noncited Violation. Major Areas Inspected:Radiological Environ Monitoring Program ML20207G8511999-06-0707 June 1999 Notice of Violation from Investigation Rept A4-1998-042 on 990127.Violation Noted:After 980528,ES Feemster,Initiated Reactor Simulator Training Attendance Record Indicating Attendance at 980528 Training Session Not Attended IR 05000313/19980211999-05-24024 May 1999 Insp Repts 50-313/98-21 & 50-368/98-01 on 981116-990406.One Violation Occurred & Being Treated as non-cited Violation. Major Areas Inspected:Review of Licensee Implementation of post-fire Alternative Shutdown Requirements ML20206S4881999-05-14014 May 1999 Insp Repts 50-313/99-07 & 50-368/99-07 on 990426-30.No Violations Noted.Major Areas Inspected:Access Authorization, Alarm Stations,Communications,Protected Area Access Control of Personnel,Packages & Vehicles & Assessment Aids IR 05000313/19990041999-05-10010 May 1999 Insp Repts 50-313/99-04 & 50-368/99-04 on 990228-0410. Non-cited Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000313/19990031999-04-0909 April 1999 Insp Repts 50-313/99-03 & 50-368/99-03 on 990202-17.No Violations Noted.Major Areas Inspected:Operations IR 05000313/19990011999-04-0202 April 1999 Insp Repts 50-313/99-01 & 50-368/99-01 on 990117-0227.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19980101999-02-0909 February 1999 Insp Repts 50-313/98-10 & 50-368/98-10 on 981206-990116.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000313/19990021999-01-25025 January 1999 Insp Repts 50-313/99-02 & 50-368/99-02 on 990111-15.No Violations Noted.Major Areas Inspected:Exposure Controls, Controls of Radioactive Matl & Contamination,Surveying & Monitoring & Program to Maintain Occupational Exposure IR 05000313/19983031999-01-0707 January 1999 NRC Operator Licensing Exam Rept 50-313/98-303 & 50-368/98-303 on 981218.Exam Results:On Reactor Operator License Applicant Passed Written Exam PNO-IV-98-066, on 981225,large Influx of Fish (Shad) Affected Unit 1 Intake Structure,Resulting in Degraded Available Circulating Water Pump Suction Pressure.Shade Runs Have Historically Occurred as Result of Cyclic Changes1998-12-29029 December 1998 PNO-IV-98-066:on 981225,large Influx of Fish (Shad) Affected Unit 1 Intake Structure,Resulting in Degraded Available Circulating Water Pump Suction Pressure.Shade Runs Have Historically Occurred as Result of Cyclic Changes IR 05000313/19980091998-12-21021 December 1998 Insp Repts 50-313/98-09 & 50-368/98-09 on 981025-1205.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support ML20196G4001998-11-19019 November 1998 Notice of Violation from Insp on 980913-1024.Violation Noted:Procedure 1104.032,Rev 51, FP Sys, Supplement 2, Surveillance Test of Diesel Fire Pump, Specified Limit on Max Coolant Temp Which Was Inconsistent Temp Set in Manual IR 05000313/19980081998-11-19019 November 1998 Insp Repts 50-313/98-08 & 50-368/98-08 on 980913-1024. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19980191998-11-11011 November 1998 Insp Repts 50-313/98-19 & 50-368/98-19 on 981019-22.No Violations Noted.Major Areas Inspected:Exposure Controls, Control of Radioactive Matls & Contamination,Surveying & Monitoring & QA Oversight of Radiation Protection Program IR 05000313/19980201998-10-27027 October 1998 Insp Repts 50-313/98-20 & 50-368/98-20 on 981019-22.No Violations Noted.Major Areas Inspected:Operational Status of Licensee Emergency Preparedness Program IR 05000313/19980071998-10-15015 October 1998 Corrected Pages to Insp Repts 50-313/98-07 & 50-368/98-07 on 980925.Typo Was Identified in Numbering of Insp Followup Sys Closed Items IR 05000368/19983011998-10-14014 October 1998 NRC Operator Licensing Exam Rept 50-368/98-301 for Test Administered on 980831-0904 ML20154H0581998-10-0808 October 1998 NRC Operator Licensing Exam Repts 50-313/98-302 & 50-368/98-302 for Tests Administered on 980914-18.Overall, Operator License Applicants Demonstrated Good Performance & Use of Good Communication Practices,As Well as Peer Checks ML20153H2461998-09-25025 September 1998 Insp Repts 50-313/98-07 & 50-368/98-07 on 980802-0912.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000313/19980161998-09-15015 September 1998 Insp Repts 50-313/98-16 & 50-368/98-16 on 980831-0904.No Violations Noted.Major Areas Inspected:Testing & Maintenance,Protected Area Barrier & Detection Aids, Compensatory Measures & Security Sys Power Supply IR 05000313/19980111998-09-0303 September 1998 Insp Repts 50-313/98-11 & 50-368/98-11 Has Been Canceled.No Other Rept Will Be Issued IR 05000313/19980151998-09-0202 September 1998 Insp Repts 50-313/98-15 & 50-368/98-15 on 980818-21.No Violations Noted.Major Areas Inspected:Licensee Performance & Capabilities During full-scale,biennial Exercise of Emergency Plan & Implementing Procedures IR 05000313/19980061998-08-18018 August 1998 Insp Repts 50-313/98-06 & 50-368/98-06 on 980621-0801. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20237C9271998-08-18018 August 1998 Notice of Violation from Insp on 980621-0801.Violation Noted:Between 970601 & 980709,four Unit 1 Sros,Five Unit 2 Sros,One Unit 1 RO & Five Unit 2 ROs Resumed Activities Authorized by License W/O Performing RO or SRO Functions IR 05000313/19980051998-07-16016 July 1998 Insp Repts 50-313/98-05 & 50-368/98-05 on 980510-0620.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support ML20248J5751998-06-0404 June 1998 Notice of Violation from Insp on 980329-0509.Violation Noted:Licensed Senior Reactor Operators Completing Listed Form Did Not Identify That Two Craftsmen Were Signed in on Hold Card 98-1-0364 IR 05000313/19980041998-06-0404 June 1998 Insp Repts 50-313/98-04 & 50-368/98-04 on 980329-0509. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20216D2521998-05-11011 May 1998 Errata to Insp Repts 50-313/98-12 & 50-368/98-12 ML20247K0301998-05-0808 May 1998 Insp Repts 50-313/98-14 & 50-368/98-14 on 980427-0501. Violations Noted.Major Areas Inspected:Access Authorization, Alarm Stations,Communications,Access Control of Personnel & Packages & Vehicles ML20247K0261998-05-0808 May 1998 Notice of Violation from Insp on 980427-0501.Violation Noted:On 980430,inspector Determined That Computer Controlled Intrusion Detection Sys Failed to Provide Audible Alarm Signal Upon Recognizing Unauthorized Access Attempt ML20217A9231998-04-17017 April 1998 Notice of Violation from Insp on 980215-0328.Violation Noted:Licensee Failed to Update Radiological Info Posting at Entrance of HPSI Pump Room a to Reflect Results of Radiological Surveys Performed Between 980221 & 0302 ML20217A9351998-04-17017 April 1998 Insp Repts 50-313/98-03 & 50-368/98-03 on 980215-0328. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000313/19980131998-04-14014 April 1998 Insp Repts 50-313/98-13 & 50-368/98-13 on 980330-0403. Violations Noted.Major Areas Inspected:Review of Radiation Protection Program Focussing on Unit 1 Refueling Outage Activities ML20236L5221998-04-13013 April 1998 Notice of Violation from Investigation on 970916-980210. Violation Noted:Mj Talley Deliberately Documented Radiation & Contamination Survey Results for Areas Which Were Not Surveyed ML20217N2711998-04-0202 April 1998 Notice of Violation from Insp on 980302-11.Violation Noted: Engineering Technique Specification Sheet Etss 4 Instructed Outage 2P98 Eddy Current Analysts to Use Phase Rotation Setting Inappropriate for Plus Point Probe ML20217N3021998-04-0202 April 1998 Insp Repts 50-313/98-12 & 50-368/98-12 on 980302-11. Violations Noted.Major Areas Inspected:Maint & Engineering ML20248L6321998-03-18018 March 1998 Notice of Violations from Insp on 971027-31 & 1110-14. Violations Noted:Activities Affecting Quality Were Not Accomplished IAW Procedure 1000.028 ML20216B8621998-03-10010 March 1998 Notice of Violation from Insp on 980104-0214.Violation Noted:Instrumentation & Control Technicians Failed to Remove Three Jumpers Before Restoring Reactor Protection Sys Channel C to Svc ML20216B8751998-03-10010 March 1998 Insp Repts 50-313/98-02 & 50-368/98-02 on 980104-0214. Violation Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20202E3401998-02-0606 February 1998 Insp Repts 50-313/97-21 & 50-368/97-21 on 971027-31 & 1110- 14.Violations Noted.Major Areas Inspected:Engineering & Plant Support.Nrc Identified Fire Barrier Deficiency & Licensee Took Promp Compensatory Actions as Required ML20202E3201998-02-0606 February 1998 Notice of Violation from Insp on 971027-31 & 1110-14. Violation Noted:As of 911123,procedure 1010.002, Transient History/Transient Cycle Logging, Was Inappropriate to Circumstances IR 05000313/19980991998-02-0404 February 1998 SALP Repts 50-313/98-99 & 50-368/98-99 for Period of 970707-980103 IR 05000313/19970081998-01-23023 January 1998 Insp Repts 50-313/97-08 & 50-368/97-08 on 971123-980103.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support PNO-IV-98-001A, on 980105,plant Shutdown When Heavy Rains Caused Accumulation of Debris at Circulating & Svc Water Intake Structure.Debris Damaged Some Intake Structure Components.Repairs to Intake Components Completed on 9801091998-01-13013 January 1998 PNO-IV-98-001A:on 980105,plant Shutdown When Heavy Rains Caused Accumulation of Debris at Circulating & Svc Water Intake Structure.Debris Damaged Some Intake Structure Components.Repairs to Intake Components Completed on 980109 1999-09-01
[Table view] |
Text
y
.
s ,.
.
.
. APPENDIX U.S. NUCLEAR REGULATORY COMMISSION
REGION IV
NRC Inspection Report: 50-313/87-37 Operating Licenses: 'NPF-6-
'50-368/87-37 DPR-51'
Dockets: 50-313 50-368 Licensee: Arkansas Power & Light Company (AP&L)
P.O. Box 551 Little Rock, Arkansas 72203 Facility Name: Arkansas Nuclear One (AN0),. Units 1 and 2 Inspection At: AND Site, Russellville, Arkansas Inspection Conducted: October 21-23 and 27-30, 1987 Inspector: # /
R. C. Stewart, Reactor Inspector, Materials & Dat'e
'
Quality Programs Section, Engineering Branch
__d, & n j /2ff/h?
gleR.C. Haag,ReactorInspector, Materials & Date Quality Programs Section, Engineering Branch
/ .
Approved: / <t. red _
/a//,s'/y7 1. Barnes, Chief, Materials & Quality Programs Date Section, Engineering Branch Inspection Summary Inspection Conducted October 21-23 and 27-30, 1987 (Report 50-313/87-37)
Areas Inspected: Routine, unannounced inspection of the justification for continued operation commitment items related to the effects of the elevated reactor building temperatures and the leakage of the lower inspection handhole cover on A and B once-through steam generator Results: Within the areas inspected, no violations or deviations were identified. Near-term action items identified in the justification for continued operations commitments appear to have been complete '
8801200077 880114 PDR ADOCK 05000313 0 . .DCD
._
_
,-
,
.
'
Inspection Conducted October 21-23 and 27-30,1987 (Report 50-368/87-37)
Areas Inspected: No inspection of Unit E was conducte Results: Not applicabl !
!
I
l I
. . . . . . - . .-
- .
.
DETAILS Persons Contacted AP&L
- D. Lomax, Plant Licensing Supervisor
- 0. Howard, Manager, Special Projects
- P. Michalk, Plant Licensing Engineer H. Green, Quality Assurance Superintendent
- Quennoz, General Manager, Operations
- McGregor, Manager (Acting), Engineering
- Ewing, General Manager, Plant Support
- Huff, Mechanical Engineering Supervisor
- J. Taylor-Brown, Quality Control Superintendent T. McDonnell, Nuclear Services
- J. McWilliams, Manager, Maintenance
- B. Baker, Manager, Operations fiRC
- Harbuck, Resident Inspector
- Denotes those present at the exit meetin The NRC inspectors also contacted other plant' per;onnel, including operators, technicians, and administrative personne . Justification for Continued Operation Commitment Items Background As a result of an initial inquiry by the NRC Senior Resident Inspector on August 3, 1987, concerning unusually high temperatures in the Unit 1 Reactor Containment Building, an inspection was
, performed by an NRC Augmented Inspection Team during August 18-20, 1987. It was ascertained from this inspection that Unit 1 containment ~
temperatures were initially identified in 1974 to range between 103'F and 180 F during plant operations. The Arkansas Nuclear One, Unit 1, Safety Analysis Report, Section 6.3, indicates that the design basis temperature for the reactor containment building under normal operating conditions is 110 F. The licensee was requested to provide a justification for continued operation (JCO) under these high temperature condition The JC0 was provided by the licensee on August 28, 1987.
, _ _ _ _ .
J
. . ,
'
,
b. Scope of Inspection The goal of this NRC inspection was to obtain a general overview of the licensee's JC0 and to verify that applicable JC0 commitments were satisfied during the midcycle outage. The licensee's main objective during the outage was.to complete _the "Near-Term Actions" identified-in Section IV of the JCO. Near-term actions were conducted to:
validate the JC0 evaluation inputs, provide a data base for future problem evaluation and/or resolution, replace or refurbish limited life components as necessary, and identify any limited temporary measures which could further reduce reactor building temperature The NRC inspectors focused their attention on the above items and the extent to which the licensee pursued these item c. Confirmatory Inspections Parformed by the Licensee These inspections were intended to validate assumptions used in the JC0 and to verify conclusions regarding equipment and structure conditions which have been exposed to the elevated reactor building temperature Selected portions of the following areas were included in this inspection:
reactor building liner and penetrations, internal structure concrete and steel (including the Swiss hammer impact tests on s91ected concrete stru;tures),
piping systems,
mechanical equipment, insulation, and instrumentation and electrical component i l
The NRC inspectors reviewed Special Work Plan (SWP) No. 1409.033, l
"ANO-1 Midcycle Outage JC0 Walkdown," Revision 0, dated October 15, 1 1987, which provides instructions to accomplish the inspections and I tests needed to fulfill JC0 commitments. For each inspection the SWP provides individual JC0 walkdown sheets which include the inspection requirements and acceptance criteria. The NRC inspectors verified that all JC0 near-term actions were included in the SWP or referenced to other work instruction l
!
l
,
.
..
.
The NRC inspectors observed portions of the walkdown inspection of the reactor building firewater' piping and supports. This inspection, which was performed by an engineer and technician, was not limited in scope to only temperature-related deficiencies but also included as-built and general type deficiencies. During this inspection, no problems resulting from elevated temperatures were discovered; however, the licensee did identify several as-built deficiencies, Following the licensee's inspection of the service water cooling coil nozzles on the 2B reactor building cooler, the NRC inspector performed a followup inspection of the nozzles. The results of both inspections indicated no damage to the nozzles. The NRC inspectors also' verified that a location which had a low Swiss hammer impact test result did have surface air-voids. The licensee had accepted of the low impact test result in accordance with ASTM C 805-85 and satisfactory testing on adjacent area The licensee informed the NRC inspectors that the walkdown inspections revealed no damage which could be attributed to reactor building elevated temperatures. Of the discrepancies discovered by the licensee inspections, the NRC inspectors verified from review of engineering evaluations and inspection documentation that proper attention and resolution were given to these items. The NRC inspectors reviewed ?2 completed JC0 walkdown sheet I d. Developing the Data Base To obtain the data base necessary to accurately model reactor 1 building conditions and to support later efforts in determining long l term actions, the licensee performed certain tests, measurements, ,
inspections, and installed additional instrumentatio '
During plant cooldown, an infrared survey of reactor coolant system (RCS) insulation was taken to identify hot spots. A visual inspection of damaged or suspect insulation was also performed. Both inspections revealed numerous areas of deficient insulatio These items were evaluated as not being an immediate safety concer No l corrective action for insulation deficiencies was performed during l this outage. During reactor building inspections, the NRC inspectors ;
noticed similar areas of insulation degradation, particularly on the chilled water system. The condition of insulation is an issue that
.
l must be addressed when dealing with the long term actions to reduce reactor building temperature The reactor building cooling system was inspected and tested to verify that performance met the minimum requirement and to provide design input for the long range action plan. Based on the results of the cooling system visual inspection and initial air flow results, the licensee repositioned several dampers and cleaned the cooling coils. Flow for the four chilled water cooling coils met the design requi ements with the exception of Coil VCC-1C, which was within 10 percent of the design flow. This condition only existed with one
.
. . .
.
chilled water pump operating. With both chilled water pumps operating, flow for Coil VCC-1C met design requirements. The system design requires that both chilled water pumps run during normal operation The NRC' inspectors observed the reactor building cooling system air flow test which was coordinated by the licensee and actually performed by a contractor. The licensee had proper control of the test with AP&L engineers verifying measurements taken by the contracto Following cleaning of the cooling coils, air flows in the cooling system met the design requirement Additional instrumentation necessary for monitoring of reactor building and cooling system conditions was installed. Using the data gathered from the instrumentation, the licensee can evaluate the
"at power" performance of the reactor building cooling system and obtain a more detailed reactor ouilding temperature profile. The NRC inspectors observed portions of the instrumentation installation and performed a final walkdown inspection of the installed-instrument The NRC inspectors noted that, while the majority of the new instruments are designed for permanent installation, the remaining equipment (i.e., multiplexer, recorders) was temporarily installe The licensee indicated that the temporary equipment will be replaced with permanent equipment during the next outage. The NRC inspectors also reviewed Design Control Plan (DCP) 870-1095, "Containment Atmosphere and Local Component Temperature Monitoring," Revision 0, which installed the additional instrumentatio e. Component Replacement In Section II (Safety Analyses) of the JCO, the licensee identified one component with a qualified lifetime that may be exceeded before the next scheduled outage. The NRC inspectors verified that this component, a reactor building pressure transmitter, was replaced during the outage. No other components were identified by the previously discussed inspections as requiring replacement or refurbishment, l
f. Temporary Temperature Reduction Measures 1 In the area of temperature reduction measures accomplished during the outage, the licensee initiated one direct modification to allow future temperature reduction This modification involved the installation of valves and tie-in connections in the chilled water system. This will provide the capability to isolate the chilled ,
water flow to the reactor building from the chilled water flow to the j
>
auxiliary and turbine building. The licensee now has the option of I adding a separate chiller unit to service the isolated auxiliary and l
.'
turbine building. Presently, the two existing chiller units will j continue supplying chilled water flow to all designed loads. The NRC ]
)
.
.....
.
'
inspectors observed portions of-the piping modification and also-reviewed DCP 87-1096, "Chilled Water System Tie-in for Future Chiller."
Based on the visual inspection of the reactor-building coolers and ( the initial airoflow test of the cooling system, the licensee cleaned the cooling coils. With the cooling system air flows now meeting design requirements and the increased cooling capacity of the cooling coils, the reactor building cooling system should now operate at a higher efficienc Quality Control Participation The-licensee's nuclear quality group performed a quality overview of various JC0 tasks accomplished during the outage. Quality assurance and quality control (QC) personnel were assigned to particular JC0 actions in the reactor building, however, while in the reactor l building they randomly reviewed 'other JC0 actions, lvhile observing j the cooling system air flow test, the NRC inspectors noted that a QC inspector assigned to the cooler nozzle inspection was also observing the air flow test. The QC engineering group also performed an initial and final review of the JC0 work pla No violations or deviations were identifie . Once-Through Steam Generator - Lower 5-inch Handhole - Flexitallic Gasket Leakage During the planned outage and a routine containment walkdown on October 22,1987, an ANO-1 operator observed evidence of a small boric acid (reactor coolant) leak on the lower, 5-inch handhole flange of the
"B" once-through steam generator (OTSG). Traces of boric acid leakage were also observed on the 5-inch handhole flange of the "A" OTS There was residual evidence of primary coolant leakage and slight l'
boric acid corrosion on the "A" handhole flange assembly. The "B" handhole flange assembly was found to have steam erosion partially through one stud i bolt and the outer area around the stud bolt. There was no evidence of damage to the stainless steel cladding, nor was there evidence of corrosion wastage. The leakage of primary coolant was estimated by the licensee to be less than .01 gpm. Repairs were made in accordance with Ap&L maintenance procedures, which included new threaded studs, new gaskets, and a new flange cover on the "B" 0TS )-
During the subsequent heatup phase of startup (week of November 8,1987),
both the "A" and "B" 5-inch handhole flange gaskets were again observed to show evidence of leakage. During the subsequent gasket replacement, the licensee employed the use of 5 millimeter thick "grafoil" tape on the flexitallic gaskets which appears to have corrected the leakage proble The licensee considers this particular repair as an interim fix until further review and analyses are mad ,
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ . _ _ _ _ _
..
,
.
During a conference call with the cognizant licensee personnel on November 10, 1987, the NRC inspector was. informed that the problem has '
been extensively discussed with both the OTSG designer, Babcock &
Wilcox (B&W), and Flexitallic Company, Both firms have concurred with the interim fi This matter is considered an open item until final corrective action is initiated (313/8737-01).
No violations or deviations were identifie . Review of Prior Reactor Coolant Pressure Boundary Leakage and Corrective Action Commitments In view of the current leakage problem with the OTSG 5-inch handhole '
flanges and the prior leakage corrosion damage found on the "A" high pressure injection (HPI) nozzle (October 1986), the NRC inspector reviewed prior corrective actions and commitments resulting from those events. In addition, the NRC inspector reviewed the licensee's response and commitments made relative to IE Bulletin No. 82-02, "Degradation of Threaded Fasteners in the Reactor Coolant Pressure Boundary of PWR Plants," dated June 2,198 Documents reviewed included the following:
AP&L letter, John R. Marshall to John T. Collins, NRC, dated August 2, 1982 (No. OCAN088201), "Initial Response to IEB 82-02" AP&L letter, John R. Marshall to John T. Collins, NRC, dated September 29, 1982 (No. OCAN098210), "Additional Information Concerning IEB 82-02" AP&L letter, John R. Marshall to John T. Collins, NRC, dated November 8, 1982 (No. OCAN118209), "Additional Information Concerning IEB 82-02" AP&L letter, John R. Marshall to John T. Collins, NRC, dated December 31, !
1982 (No. 2CAN128218), "Report Required by IEB 82-02, Action Item 4" l AP&L letter, John R. Marshall to W. C. Seidle, NRC, dated March 24, 1983 (No. 2CAN038312), "Quality Assurance Regarding Threaded Fasteners" AP&L letter, John R. Marshall to W. C. Seidle, NRC, dated April 21, 1983 (No. 2CAN048308), "Quality Assurance Regarding Threaded Fasteners" AP&L letter, John R. Marshall to John T. Collins, NRC, dated July 25, 1983 (No. ICAN078310), IEB 82-02, Action Item 4" AP&L inter C apany Correspondence, David Young to A. B. McGregor, dated ;
November 6, 1986 (No. ANO-86-14401) "Workplan for Concentrated Boric Acid l Attack on ANO, Unit 1 RCS" i l
l i
l
. -- . - .
,
.
...
.
.
NRC IE Inspection Report 50-313/82-19, dated October 7, 1982 !
NRC IE Inspection Report 50-313/82-30, dated December 7, 1982 NRC IE Inspection Report 50-313/82-32, dated December 23, 1982
,
- NRC IE Inspection Report 50-313/83-10, dated June 15, 1983
'
NRC IE Inspection Report 50-313/83-34, dated January 20, 1984
- !
NRC IE Inspection Report 50-313/86-36, dated December 23, 1986 In reviewing the historical documentation relative to threaded fasteners in the reactor coolant pressure boundary (RCPB), the NRC inspector noted
"
,
that ANO Units 1 & 2 have had a limited number of primary coolant leaks occurring on bolted closures during their commercial operating historie It was noted~by the NRC inspector that during the 1982-83 period, in
] response to IEB 82-02 action items, the-licensee expanded the then existing administrative program controls and procedures (which include training and inspection requirements applicable to RCPB fasteners).
As a resu'it of discovering boric acid corrosion during an inservice ,
inspection (ISI) examination of the "A" HPI nozzle in October 1986, IE Inspection Report 50-313/86-36, dated December 23, 1986, the licensee initiated an inspection and evaluation program involving 68 locations in the RCS, which had the potential for leakage and to determine whether the corrosion mechanism was active in those area The licensee's workplan, dated November 6, 1986, included the following statement:
, "Acceptance criteria for preliminary concentrated boric acid attack inspections will be as follows:
,
! There shall be no red rust on carbon steel surface . There shall be no visible residual boron deposit . There shall be no corrosion attack, pitting or grooving of carbon steel surfaces of dissimilar weld metal interface.
,
Indications that fail to meet any of the three above criteria will be
.
documented in Section E of the worksheet. These will be evaluated for j further action."
The NRC inspector observed that records of inspections performed on
.
November 17 and 20, 1986, identified residual deposits of boric acid on j OTSG "A" and "B" handhole flange bolts, respectivel The evaluations
- regarding those deposits state, "These crystals should be removed during j IR8 (Unit 1, refueling outage 8), and the bolts should be reinspected at that time."
- _ _ . _ . - - _ _ __ . ,_ __ , . _ _ . _ . __ ._ _ _ .. ,
.
'
,
Since the primary coolant erosion.found on the lower handhole flange assembly of OSTG B discovered during this outage was of-principal concern ,
during this inspection, this matter was ey.tensively discussed during the exit meeting held on October 30, 198 The licensee representatives indicated that since.the boric acid crystals did not appear to threaten the structural integrity of the OTSG and because of ALARA considerations (150R at the surface), cleaning and reinspection was deferred. However,.in view of the present concern, the
.
licensee committed to reviewing the acceptance' criteria established in the
methods of evaluating this type of. inspection / observations. This matter-is considered an open item pending completion of licensee review of acceptance criteria and NRC evaluation (313/8737-02).
No violations or deviations were identifie . Exit Interview i The NRC inspectors met with the licensee personnel denoted in paragraph 1
and the resident inspector on October 30, 1987, and summarized the scope and finding of the inspection.
, -
r
h i
l J
I I
l
i