1

.

j

.

-5-

submitted an initial portion of the third 10-year inservice inspection program plan to the Office of

Nuclear Reactor Regulation for review.

M3.2 Inservice insoection Proaram Examination Records

a.

Insoection Scooe (73753)

The inspectors reviewed completed examination records for 46 nondestructive inservice

inspection examinations (listed in the attachment to this inspection report) performed

during Unit 2 Refueling Outage 2R12. The examination records were reviewed to verify

that examination activities and results were documented in accordance with the

i

licensee's program, procedure, and ASME Code requirements,

b.

Observations and Findinas

The inspectors determined that the reviewed examination records had been prepared in

accordance with licensee program, procedure, and ASME Code requirements.

c.

Conclusions

The reviewed insiervice inspection examination records were documented appropriately.

M3.3 Inservice insoection Proaram Plan Reauirements

a.

Insoection Scooe (73753)

The inspectors reviewed licensee activities for evaluating the Unit i second 10-year

'

inservice inspection examination data, to ensure examinations were performed in

accordance with the requirements of Section XI of the ASME Code and

10 CFR 50.55(a).

1

b.

Observations and Findinos

The inspectors noted that during review of nondestructive examinations performed

for the Unit 1 second 10-year inservice inspection interval, the licensee discovered

that inspection period distribution requirements had not been met for certain

Section XI ASME Code Examination Categories. Additionally, this review revealed

that, as a consequence of improperly distributing examinations, only 35 of the

39 required Section XI ASME Code Examination Category C-C integral attachment

weld examinations had been performed. The licensee issued Condition

Report CR-ANO-1-1998-0127, to document this failure to inspect in accordance with

the Section XI ASME Code requirements. A subsequent operability assessment found

allimpacted components remained operable. This licensee-identified and corrected

violation is being treated as a noncited violation, consistent with Section Vll.B.1 of

the NRC Enforcement Policy (50-313/9812-01).

9905200318 990511

PDR

ADOCK 05000313

G

PDR