Event date:
Report date:
3951982028R00 - NRC Website

text

_

SOUTH CAROLINA ELECTRIC & GAS COMPANY, _

[I }

post oprics 7e4 t

Cot.UMstA. SOUTH CAROUNA 29218

  • d' Q - /-

' ' l r l=

O. W. DixON, JR.

Vics Passiosmt i

/

uucts.. Ona no"*

November 19, 1982 1

4 '- : 58 Mr. James P. O'Reilly, Director U.S. Nuclear Regulatory Commission Region II, Suite 3100 101 Marietta Street, N.W.

Atlanta, Georgia 30303

SUBJECT:

Virgil C.

Summer Nuclear Station Docket No. 50/395 Operating License No. NPF-12 Thirty Day Written Report LER 82-028

Dear Mr. O'Reilly:

Please find attached Licensee Event Report #82-028 for Virgil C.

Summer Nuclear Station.

This Thirty Day Report is required by Technical Specification 6.9.1.13.(b) as a result of entry into Action Statement (a) of Technical Specification 3 3.3.10,

" Instrumentation, Loose-Part Detection Instrumentation," on October 22, 1982.

Should there be any questions, please call us at your convenience.

Very trul-yours, e

'N fg/

s.

O. W.

Dixon, r.

ARK:0WD:dwr Attachment cc:

V.

C.

Summer A.

R. Koon T.

C. Nichols, Jr.

H. Radin G.

H. Fischer Site QA 0.

W. Dixon, Jr.

C. L. Ligon (NSRC)

H.

N. Cyrus G.J. Braddick H. T. Babb J. L.

Skolds D.

A.

Nauman J. B. Knotts, Jr.

M.

B. Whitaker, Jr.

B.

A. Bursey W.

A. Williams, Jr.

I&E (Washington)

O.

S.

Bradham Document Management Bra h

R.

B.

Clary INFO Records Center.np,

M. N. Browne NPCF 4-2 File gy p

8211290648 821119 d

PDR ADOCK 05000395 r

g PDR

3

/

Mr. James P. O'Reilly LER No.82-028 Page Two November 19, 1982 s

DETAILED DESCRIPTION OF EVENT On October 22, 1982, the Plant entered Mode 2 for initial criticality with the Loose-Part Detection System inoperable with respect to Technical Specification 3.3.3.10.

(Specification 3 0.4 is not applicable.)

PROBABLE CONSEQUENCES There were no adverse consequences resulting from this event.

Even though modifications were being performed, the system was in operation and functio,nal.

CAUSE(S) OF THE UCCURRENCE l

Modifications were being performed on the Loose-Part Monitoring System that were not complete at the time the Plant entered Mode 2.

Therefore, the applicable surveillances had not been performed.

IMMEDIATE CORRECTIVE ACTIONS TAKEN The modifications were completed on the system, and the applicable Technical Specification surveillance tests were performed on November 9, 1982.

Af ter a time period of system operating observation, the system was returned to operable status on November 19, 1982.

i n

s ACTION TAKEN CO FREVENT RECURRENCE

.t With the exception of the Technical Specification required surveillances, the licensee plans no further actions.

\\

i s