ML20059K40717 September 1990Advises That Author Succeeded Os Bradham as vice-president, Nuclear Operations,Effective 900915.All Correspondence to Util Should Be Sent to Listed Address
ML20059J91414 September 1990Responds to Violations Noted in Insp Rept 50-395/90-21. Violation Occured,However Description of Violation in Error. Corrective Action:Valve XVT02803B Placed in Proper Position & Verification of Emergency Feedwater Sys Lineup Completed
ML20059E28230 August 1990Advises That Programmed Enhancements Per Generic Ltr 88-17 Re Loss of DHR Implemented & Mods Operable
ML20059D69129 August 1990Forwards Technical Rept 90-02, Seismic Activity Near VC Summer Nuclear Station for Apr-June 1990
ML20059B95428 August 1990Forwards Semiannual Effluent & Waste Disposal Rept for Jan-June 1990, Per 10CFR50.36a & Sections 6.9.1.8 & 6.9.1.9 of Tech Spec
ML20056B49022 August 1990Discusses NRC Bulletin 88-004, Potential Safety-Related Pump Loss. Decision on Future Insp Frequency &/Or Sys Mods Should Be Deferred Until Internal Components Could Be Inspected
ML20059A20416 August 1990Forwards First Semiannual fitness-for-duty Rept from 900103- 0630.Util Pleased W/Program,However,Concerned About Incorrect Test Results for Blind Performance Specimens Received from Roche LabsFitness for Duty
ML20058P65815 August 1990Forwards Monthly Operating Rept for Jul 1990 & Rev 13 to ODCM for Virgil C Summer Nuclear Station.Rev Implements Changes Necessary to Permit Removal of Radiological Effluent Specs from Tech Specs as Recommended by Generic Ltr 89-01Offsite Dose Calculation Manual
ML20058P76813 August 1990Forwards Mods to 900516 Tech Spec Change Request Re Pressurizer Code Safety Valve Setpoint Tolerance & Mode 3 Exception,Per 900713 Telcon.Changes Do Not Affect Technical Intent of 900516 Submittal Nor Alter Safety Evaluation
ML20058N69610 August 1990Responds to Violations Noted in Insp Rept 50-395/90-18. Corrective Action:Personnel Counseled on Procedural Compliance & Importance of Independent Verification in Maintaining Proper Sys Alignment
ML20056A3441 August 1990Responds to NRC Request for Further Justification Re Relocating Emergency Operations Facility to Corporate Headquarters
ML20059A36930 July 1990Ack Receipt of SALP Rept 50-395/90-11 & Forwards Comments on Rept
ML20056A02027 July 1990Provides Notification That All Actions Re Generic Ltr 88-14, Instrument Air Supply Sys Problems Affecting Safety-Related Equipment, Completed
ML20055H98220 July 1990Forwards Amend 28 to Physical Security Plan.Amend Withheld (Ref 10CFR73.21)
ML17305B76819 July 1990Responds to NRC NRC Bulletin 90-001, Loss of Fill Oil in Transmitters Mfg by Rosemount. No Transmitters Identified in Item 1 from Suspect Lots Identified by RosemountEmergency Lighting
ML20044B02411 July 1990Responds to Violations Noted in Insp Rept 50-395/90-15. Corrective Actions:Relay Rewired & Verified Against Design Drawings
ML20055F36310 July 1990Forwards Rev 1 to Plant Core Operating Limits Rept Cycle 6, as Result of Typo
ML20055E0345 July 1990Forwards Technical Rept 90-1, Seismic Activity Near VC Summer Nuclear Station for Period Jan-Mar 1990
ML20055D4663 July 1990Forwards Amend 4 to Updated Virgil C Summer Nuclear Station Fire Protection Evaluation Rept, Effective 900301
ML20058K44229 June 1990Forwards Response to Generic Ltr 90-04 Re Status of Licensee Implementation of Generic Safety Issues Resolved W/Imposition of Requirements or Corrective ActionsScram Discharge Volume
ML20043F6627 June 1990Requests for Change in QA Program 10CFR50.54 & FSAR Biennial Reviews of Plant Procedures Based on Justification Contained in Proposed Change to FSAR.SAP-139 Will Be Revised Immediately Following Approval of Request
ML20043D5861 June 1990Forwards LERs 90-004 & 90-006 Which Respond to Violation Noted in Insp Rept 50-395/90-12.Corrective Actions:Training Conducted & Tech Spec Instruments Evaluated for Adequate Testing
ML20043C50029 May 1990Forwards marked-up Pages to Util 900410 Tech Spec Change Request Indicating Location of Incorrect Std Refs,Per 900419 Telcon W/Jj Hayes
ML20043B73523 May 1990Forwards Rev 0 to Core Operating Limits Rept,Cycle 6.
ML20043A91817 May 1990Forwards List Detailing Tubes in Which F* Criteria Applied During Steam Generator Tube Insp Subsequent to Fifth Inservice Eddy Current Exam.Location of Degradation Measured from Tube End on Hot/Cold Leg Up to Degradation
ML20043G4623 May 1990Advises That Util Will Control Operations to Abide by More Restrictive Required Shutdown Margin Curve While Awaiting NRC Approval to Place Revised Curve in Tech SpecsShutdown Margin
ML20042G4741 May 1990Special Rept Spr 90-003 Listing Number of Steam Generator Tubes Plugged or Repaired During Fifth Refueling Outage
ML20042E19311 April 1990Forwards Seismic Activity Near VC Summer Nuclear Station, Oct-Dec 1989. Several Seismic Monitoring Stations Inoperable During Reporting Period & Also During First Quarter 1990
ML20012F3553 April 1990Withdraws 900321 Request for Relief from Testing RHR Containment Isolation Valves Xvg 08701 A/B at Frequency Specified in ASME Section XI Code.Meeting Requested to Discuss Util Interpretation of Testing in 10CFR50,App J
ML20012E90623 March 1990Submits Supplemental Response to Station Blackout Re Proper Documentation & Consistent Implementation of NUMARC 87-00 Guidance.Plant Currently Maintains Targeted Emergency Diesel Generator Reliability by Ensuring Compliance W/Tech SpecsSafe Shutdown
ML20012E04323 March 1990Forwards Corrected Pages to Rev 26 to Radiation Emergency Plan.
ML20012D96923 March 1990Forwards, Sante Cooper 1989 Annual Financial Rept, South Carolina Gas & Electric 1989 Annual Financial Rept Summary of Present Levels of Property Insurance & Cash Flow Statement for VC Summer Nuclear Plant
ML20012E58821 March 1990Forwards Corrected Slide to Clarify Util Current Plans Re Steam Generator Insp Plan,Per 900312 Meeting W/Nrc
ML20012D82721 March 1990Requests Relief from Testing RHR Containment Isolation Valves Xvg 08701 A/B at Frequency Specified in ASME Section XI Code.Valves Will Be Tested at Frequency Specified for Type a Valves in 10CFR50,App J
ML20012D03719 March 1990Responds to Generic Ltr 89-19 Re Design of Steam Generator Overfill Protection.Util Does Not Plan to Implement Physical Mods or Administrative Changes Since Overfill Protection Sys Meets or Exceeds Guidance in Generic Ltr
ML20012D47816 March 1990Forwards First Annual ECCS Evaluation Model Revs Rept,Per 881017 Rev to 10CFR50.46.Rept Identifies Several Mods to Large & Small Break LOCA Evaluation Models Used at Facility & Provides Estimated Effects of Changes on ECCS AnalysesFuel cladding
ML20012C0669 March 1990Forwards Addl Info Re Natural Circulation Evaluation Program Rept,Per 900208 Telcon Request
ML20012A0921 March 1990Forwards Response to Generic Ltr 90-01,consisting of Completed NRC Regulatory Impact Survey Questionnaire Sheets Containing Estimates of Time Spent by Managers on Insps & Audits
ML20006E3416 February 1990Forwards Proprietary Addl Info,Per NRC 900104 Request,Re Util Tech Spec Change Request for Elimination of Resistant Temp Detector Bypass Manifold sys,marked-up Tech Spec Pages & Block Diagrams.Encls Withheld
ML20006D1241 February 1990Requests Approval,Per 10CCFR50.55a,for Use of Alloy 690 Matl in Fabricating/Use of Steam Generator Plugs During Upcoming Refueling Outage.Alloy 690 Currently code-approved Matl for Steam Generator Tubing Based on Corrosion Resistance
ML20011E12131 January 1990Forwards Response to Generic Ltr 89-13, Svc Water Sys Problems Affecting Safety-Related Equipment. Util Currently Performs Visual Insps & Dredgings of Svc Water & Circulating Water Intake Structures Once Each Refueling CycleCoatings
Biofouling
ML20006D29526 January 1990Forwards WCAP-12464, VC Summer Nuclear Station Natural Circulation Evaluation Program Rept. Rept Provides Info to Resolve Branch Technical Position Rsb 5-1, Design Requirements for RHR Sys for Facility,Per 890719 Telcon
ML20006B12124 January 1990Forwards Technical Rept 89-3, Seismic Activity Near VC Summer Nuclear Station for Period Jul-Sept 1989.
ML20006A71919 January 1990Provides Update of long-term Corrective Action for 890711 Loss of Offsite Power.Installation of Voltage Regulator on 230/7.2 Kv Emergency Auxiliary Transformer Neither Required Nor Any Appreciable Benefit Derived from Installation
ML20006A55216 January 1990Advises That Util Will Validate Adequacy of Any Sys Used for Periodic Inservice Insp & Will Upgrade,As Required,Eddy Current Test Methods Used as Better Methods Developed & Validated for Commercial Use,Per 900111 Discussion
ML20005H07912 January 1990Advises That Response to NRC Request for Addl Info Re L* Implementation Will Be Submitted by 900801 Due to Refueling Outage Schedule
ML20005F1195 January 1990Forwards Description of F* Application at Plant & Sample Eddy Current Lissajous Figures for 12 Steam Generator Tubes, Per 891218 Request for Extension of Application of F* Tube Plugging Criterion for Life of Steam Generators
ML20005G4925 January 1990Responds to NRC Bulletin 89-003, Potential Loss of Required Shutdown Margin During Refueling Operations. Bulletin & Core Shuffle Procedure Will Be Discussed Among Core Engineering Personnel in Documented Training SessionShutdown Margin
ML20005F4534 January 1990Forwards Application for Approval to Incinerate Oil Contaminated W/Very Low Levels of Licensed Radioactive Matls within Site Boundary of FacilityOffsite Dose Calculation Manual
ML20005F0603 January 1990Forwards Justification for Continued Operation Re Pressurizer Surge Line Thermal Stratification,Per NRC Bulletin 88-011.Util Believes That Plant Can Continue Operation for at Least 20 Addl Heatup/Cooldown CyclesThrough Wall Leak