05000293/LER-1982-046, Forwards LER 82-046/01T-0

From kanterella
(Redirected from 05000293/LER-1982-046)
Jump to navigation Jump to search
Forwards LER 82-046/01T-0
ML20066J803
Person / Time
Site: Pilgrim
Issue date: 11/10/1982
From: Mathis C
BOSTON EDISON CO.
To: Haynes R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20066J814 List:
References
82-290, NUDOCS 8211290305
Download: ML20066J803 (1)


LER-2082-046, Forwards LER 82-046/01T-0
Event date:
Report date:
2932082046R00 - NRC Website

text

_ _ - _

. Ed,ison co-m PitoniM NUCLEAR POWER STATION RFD No 1 Rocnv HILL RoAo PL Y M O UT H _ MASSACHUSETTS O2360 November 10, 1982 C J MATHIS ST A TION M AN AGE R mc ,o sr AT,ou BECo Ltr. #82-290 Ronald C. Haynes Regional Administrator, Region 1 U. S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, PA 19406 Docket Number 50-293 License DPR-35

Dear Sir:

The attached Licensee Event Report 82-046/01T-0, "HPCI MOV 2301-3 Steam Leak",

is hereby submitted in accordance with the requirements of Pilgrim Nuclear Power Station Technical Specification 6.9.B.1.e.

BEco believes that the intent of Regulatory Guide 1.16 Section 2.9.5.c, which provides guidance on determining reportability of events per the Technical Specification referenced above, is to report promptly those events where re-dundancy is not available. Therefore, in the future PNPS will report events of this nature in accordance with 6.9.B.2.b of the Technical Specifications.

If there are any questions on this subject, please contact us.

Respectfully submitted, d

C. J. Mathis Station Manager Pilgrim Station CGW:cp

Enclosure:

LER 82-046/01T-0 cc: Document Control Desk U. S. Nuclear Regulatory Commission Washington, D.C. 20555 Standard BECo LER Distribution F211290305 821110 DR ADOCK 050QO293 PDR .y