Download: ML20066E362 (1)


LER-1982-047, Forwards LER 82-047/03L-0
Event date:
Report date:
2931982047R00 - NRC Website

text

+.,.

o Ed" ison com,

$@$f0N PILGRIM NUCLEAR POWER STATION RFD No_1 rocky HILL RoAo PLYMOUTH. M ASSACHUSETTs 02360 November 3, 1982 c ; uArwis

'II'c'n,". "s^r"r' iou BECo Ltr. #82 28Z Ronald C. Haynes Regional Administrator, Region i U. S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, PA 19406 Docket Number 50-293 License'DPR Dear Sir:

The attached Licensee Event Report 82-047 /03L-0 entitled "RWCU 3/4" Vent Crack",

is hereby submitted in accordance with the requirements of Pilgrim Nuclear Power Station Technical Specification 6.9.B.2.b.

If there are any questions on this subject, please contact us.

Respectfully submitted,

," 1 C. J. Mathis Station Manager Pilgrim Station MTM:ep Enclosure: LER 82-047/03L-0 cc: Director Office of Management Information and Program Control U. S. Nuclear Regulatory Commission Washington, D.C.

20555 Standard BECo LER Distribution

~

8211150129 8211O3 PDR ADOCK 05000293 S

PDR fb