05000293/LER-2007-001, Regarding Primary Containment Isolations Following a Manual Reactor Scram

From kanterella
(Redirected from 05000293/LER-2007-001)
Jump to navigation Jump to search

Regarding Primary Containment Isolations Following a Manual Reactor Scram
ML071420092
Person / Time
Site: Pilgrim
(DPR-035)
Issue date: 05/16/2007
From: Bronson K
Entergy Nuclear Operations
To:
Document Control Desk, Plant Licensing Branch III-2
References
2.07.049 LER 07-001-00
Download: ML071420092 (6)


LER-2007-001, Regarding Primary Containment Isolations Following a Manual Reactor Scram
Event date:
Report date:
Reporting criterion: 10 CFR 50.73(a)(2)(i)

10 CFR 50.73(a)(2)(vii), Common Cause Inoperability

10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded

10 CFR 50.73(a)(2)

10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition

10 CFR 50.73(a)(2)(viii)(B)

10 CFR 50.73(a)(2)(iii)

10 CFR 50.73(a)(2)(ix)(A)

10 CFR 50.73(a)(2)(iv)(A), System Actuation

10 CFR 50.73(a)(2)(x)

10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor

10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat

10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown

10 CFR 50.73(a)(2)(v), Loss of Safety Function

10 CFR 50.73(a)(2)(1)
2932007001R00 - NRC Website

text

'ý Entergy Entergy Nuclear Operations, Inc.

Pilgrim Nuclear Power Station 600 Rocky Hill Road Plymouth, MA 02360 Kevin H. Bronson Site Vice President May 16, 2007 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555

SUBJECT:

Entergy Nuclear Operations, Inc.

Pilgrim Nuclear Power Station Docket No: 50-293 License No. DPR-35 Licensee Event Report 2007-001-00 LETTER NUMBER:

2.07.049

Dear Sir or Madam:

The enclosed Licensee Event Report (LER) 2007-001-00, "Primary Containment Isolations Following a Manual Reactor Scram" is submitted in accordance with 10 CFR 50.73.

This letter contains no commitments.

Please contact Bryan Ford, (508) 830-8403, if there are questions regarding this subject.

Sincerely Kevin H. Bronson ERS/di Enclosure cc:

Mr. James Kim, Project Manager Plant Licensing Branch I-1 Division of Operator Reactor Licensing Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission One White Flint North O-8C2 11555 Rockville Pike Rockville, MD 20852 INPO Records 700 Galleria Parkway Atlanta, GA 30399-5957 Mr. Samuel J. Collins Regional Administrator, Region 1 U.S. Nuclear Regulator Commission 475 Allendale Road King of Prussia, PA 19406 Senior Resident Inspector Pilgrim Nuclear Power Station

1.

NRC Form 366 U.S. NUCLEAR REGULATORY COMMISSION Estimated burden per response to comply with this mandatory Information collection request: 50 hrs. Reported lessons learned are incorporated Into the licensing process and fed back to industry. Forward comments regarding burden LICENSEE EVENT REPORT (LER) estimate to the Records Management Branch 0"-6 F33), U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, and to the Paperwork Reduction Project (3150-0104), Office of Management and Budget, Washington, DC 20503.

FACILITY NAME (1)

DOCKET NUMBER (2)

PAGE(3)

PILGRIM NUCLEAR POWER STATION 05000-293 1 of 5 TITLE (4)

Primary Containment Isolations Following a Manual Reactor Scram EVENT DATE (5)

LER NUMBER (6)

REPORT DATE (7)

OTHER FACILIES INVOLVED (8)

I SEQUENTIAL NUMBER I REVISION J

FACILITY NAME DOCKET NUMBER MONTH DAY YEAR YEAR NUMBER MOYNT D

'~'

N/A 05000 FACILITY NAME DOCKET NUMBER 03 17 2007 2007 001 00 05 16 2007 N/A 05000 OPERATING THIS REPORT IS SUBMITTED PURSUANT TO THE REQUIREMENTS OF 10 CFR: (Check one or more) (11)

MODE (9)

N 20.2201(b) 22.2203(a)(3)(i) 50.73(a)(2)(i)(C) 50.73(a)(2)(vii)

POWER 22.2202(d) 20.2203(a)(3)(ii) 50.73(a)(2)(ii)(A) 50.73(a)(2)(vyii)(A)

LEVEL (10) 0 20.2203(a)(1) 20.2203(a)(4) 50.73(a)(2)(ii)(B) 50.73(a)(2)(viii)(B) 20.2203(a)(2)(1) 50.36(3)(1)(i)(A) 50.73(a)(2)(iii) 50.73(a)(2)(ix)(A) 20.2203(a)(2)(ii) 50.36(3)(1)(ii)(A)

X 50.73(a)(2)(iv)(A)

I 50.73(a)(2)(x) 20.2203(a)(2)(lil) 50.36(c)(2) 50.73(a)(2)(v)(A) 73.71(a)(4) 20.2203(a)(2)(iv) 50.46(a)(3)(1U) 50.73(a)(2)(v)(B) 73.71 (a)(5) 20.2203(a)(2)(v) 50.73(a)(2)(i)(A) 50.73(a)(2)(v)(C)

OTHER 20.2203(a)(2)(vl)

_50.73(a)(2)(1)(B)

__50.73(a)(2)(v)(D)

Specify In Abstract below or In NRC Form 366A

- LICENSEE CONTACT FOR THIS LER (12)

NAME TELEPHONE NUMBER (Include Area Code)

Bryan Ford, Licensing Manager 1(508) 830-8403 COMPLETE ONE UNE FOR EACH COMPONENT FAILURE DESCRIBED IN THIS REPORT(113)

REPORTABLE REPORTABLE

CAUSE

SYSTEM COMPONENT MANUFACTURER TO EPIX

CAUSE

SYSTEM COMPONENT MANUFACTURER TO EPIX E

CE V

L200 Y

SUPPLEMENTAL REPORT EXPECTED (14)

EXPECTED MONTH DAY YEAR YES IS NO UBMISSION (If yes, complete EXPECTED SUBMISSION DATE)

_x__N°_DATE(15)

ABSTRACT (ULmit to 1400 spaces, I.e., approxImately 15 single-spaced typewritten lines) (16)

On March 17, 2007, at approximately 1655 hours0.0192 days <br />0.46 hours <br />0.00274 weeks <br />6.297275e-4 months <br />, a manual scram was initiated while at 30 percent reactor power during an orderly shutdown of the unit. The orderly shutdown was a management decision based on observing an increasing trend in reactor coolant system (RCS) unidentified leak rate. The manual scram was performed because the increase in RCS unidentified leak rate reached administrative limits during the shutdown.

There were no complications encountered during the response to the scram.

Following the scram, the collapse of steam voids caused a shrink in the reactor water level and resulted in automatic actuation of the Primary Containment Isolation Control System (PCIS) and Reactor Building Isolation Control System (RBIS). No actuations of emergency core cooling systems, reactor safety/relief valves, or standby diesel generators were required.

The root cause of the increase in unidentified leakage was the failure of the valve packing for Reactor Water Clean-up (RWCU) valve MO-1 201-85, which is located inside primary containment in the drywell and is not accessible during power operation. The failure was due to inadequate preventive maintenance of the valve packing. Corrective action taken included replacement of the valve packing. Corrective action planned includes developing a packing adjustment procedure and scheduling preventive maintenance for packing adjustments to critical valves in the drywell and other inaccessible areas using guidelines published by EPRI.

The event posed no threat to public health and safety.

NRC FORM 366U.S. NUCLEAR REGULATORY COMMISSION LICENSEE EVENT REPORT (LER)

TEXT CONTINUATION FACIUTY NAME (1)

DOCKET NUMBER 2 LER NUMBER (6 PAGE (3)

SEQUENTIAL REVISION YEAR NUMBER NUMBER PILGRIM NUCLEAR POWER STATION 05000-293 2007 001 00 2 of 5 TEXT (If more space Is required, use additional copies of NRC Form 366A) (17)

BACKGROUND The Reactor Water Cleanup System (RWCU) functions to purify the reactor coolant water by continuously removing a portion of the reactor recirculation flow from the suction side of a recirculation pump, sending the removed flow through filter demineralizer units to undergo mechanical filtration and ion exchange processes, and returning the processed fluid back to the reactor via the feedwater line. The major equipment of the system consists of the two cleanup recirculation pumps, regenerative and non-regenerative heat exchangers, and two filter demineralizer units with supporting equipment. Water from the reactor first enters the regenerative heat exchanger, then the non-regenerative heat exchanger, and finally the pumps. The water cooled by the heat exchanger then flows through two parallel filter demineralizer units for the removal of impurities. Normal routing of flow from the filter demineralizer units is then through the shell side of the regenerative heat exchanger where it is heated by the incoming (untreated) coolant, to the temperature range of reactor feedwater. It is then returned to the reactor through the Feedwater System.

Valve MO-1201-85 is a valve in the RWCU inlet line that draws suction from the A loop of the reactor recirculation system. MO-1201-85 is not a containment isolation valve or a reactor pressure vessel isolation valve.

During the operating cycle, a slow increase in equipment and floor sump inleakage had been observed.

Pilgrim entered these observations into the Corrective Action Program and created a comprehensive action plan under the Operational Decision Making Issue (ODMI) process to ensure proper focus and resources were applied to determining the likely sources of unidentified RCS leakage, monitoring and trending it's status, and developing various thresholds and trigger points for specific response actions.

EVENT DESCRIPTION

At midnight on 3/17/07, Operations personnel observed an increase in the Drywell floor sump inleakage rate. The calculated floor sump inleakage rate had climbed from 0.58 gpm to 0.65 gpm. Over the next several hours the rate of unidentified RCS leakage continued to increase. At 1130 hours0.0131 days <br />0.314 hours <br />0.00187 weeks <br />4.29965e-4 months <br /> on 3/17/07, a decision was made to commence an orderly shutdown of the unit. Shutdown commenced at 1230 hours0.0142 days <br />0.342 hours <br />0.00203 weeks <br />4.68015e-4 months <br />.

During the shutdown, RCS unidentified leakage continued to increase and at 1655 hours0.0192 days <br />0.46 hours <br />0.00274 weeks <br />6.297275e-4 months <br /> a manual scram was initiated in accordance with PNPS procedures because administrative limits were reached. Prior to the manual reactor shutdown, leakage did not reach the applicable Technical Specification limits presented in TS 3.6.C.1. At 1657 hours0.0192 days <br />0.46 hours <br />0.00274 weeks <br />6.304885e-4 months <br />, all control rods were verified to be fully inserted.

As expected, the scram caused a decrease in the void fraction in the reactor vessel water, which in turn caused the indicated water level in the reactor vessel to decrease. Indicated water level decreased to about -12 inches (narrow range level). The decrease in reactor water level to less than +12 inches resulted in the expected automatic actuation of the Primary Containment Isolation Control System (PCIS) and Reactor Building Isolation Control System (RBIS).

The PCIS actuation resulted in the automatic closing of the Primary Containment system (PCS) Group 2 and Group 6 (RWCU) isolation valves that were open.

The RBIS actuation resulted in the automatic start of the Standby Gas Treatment system (SGTS) trains 'A' and 'B', and automatic closing of the Reactor Building/Secondary Containment system (SCS) trains 'A' and 'B' supply and exhaust ventilation dampers.

NRC Farm 366A U.S. NUCLEAR REGULATORY COMMISSIONU.S. NUCLEAR REGULATORY COMMISSION LICENSEE EVENT REPORT (LER)

TEXT CONTINUATION FACILITY NAME (1)

DOCKET NUMBER (2)

LER NUMBER (6)

PAGE SEQUENTIAL REVISION YEAR NUMBER NUMBER PILGRIM NUCLEAR POWER STATION 05000-293 2007 001 00 3 of TEXT (If more space Is required, use additional copies of NRC Form 366A) (17)

At about 1733 hours0.0201 days <br />0.481 hours <br />0.00287 weeks <br />6.594065e-4 months <br />, the Reactor Protection System (RPS) was reset. While all rods remained fully inserted, the SDIV Hi Level bypass switch was mispositioned due to a human performance error at about 1735 hours0.0201 days <br />0.482 hours <br />0.00287 weeks <br />6.601675e-4 months <br /> generating an RPS signal. RPS was reset at about 1735 hours0.0201 days <br />0.482 hours <br />0.00287 weeks <br />6.601675e-4 months <br />. The RBIS was reset, the SGTS was returned to normal standby service, and the reactor building ventilation system was returned to service.

During a drywell entry at 1235 hours0.0143 days <br />0.343 hours <br />0.00204 weeks <br />4.699175e-4 months <br /> on 3/18/07, it was determined that the source of the increased floor sump inleakage was the packing on MO-1201-85. Valve MO-1201-85 is a valve in the RWCU inlet line that draws suction from the A loop of the reactor recirculation system. MO-1201-85 is not a containment isolation valve or a reactor pressure vessel isolation valve.

CAUSE

The root cause of the increase in unidentified leakage was the failure of the valve packing for Reactor Water Clean-up (RWCU) valve MO-1201-85, which is located inside primary containment in the drywell and is not accessible during power operation. The failure was due to inadequate preventive maintenance of the valve packing.

CORRECTIVE ACTION

Corrective actions taken included the following:

" On 3/18/07, it was determined that the source of the increased floor sump leakage was leakage through the packing on MO-1201-85.

  • On 3/19/07, the valve was re-packed, post-work tested and returned to service.
  • Individuals were coached on the use of human performance tools to address the error that occurred while resetting the RPS signal.

Corrective actions planned include the following:

Developing a packing adjustment procedure and scheduling preventive maintenance for packing adjustments to critical valves in the drywell and other inaccessible areas using guidelines published by EPRI.

These planned corrective actions may be supplemented or modified in accordance with the corrective action process.U.S. NUCLEAR REGULATORY COMMISSION LICENSEE EVENT REPORT (LER)

TEXT CONTINUATION FACILITY NAME (1)

DOCKET NUMBER 2 LER NUMBER (6)

PAGE (3)

SEQUENTIAL T REVISION YEAR NUMBER I NUMBER PILGRIM NUCLEAR POWER STATION oso0-293 2007 001 00 4of 5 TEXT (If more space is required, use additional copies of NRC Form 366A) (17)

SAFETY CONSEQUENCES

The decrease in the reactor vessel water level was expected in response to the scram due to shrinkage in the water level caused by steam void collapse. The consequent actuations were the expected designed responses to a low reactor vessel water level condition, i.e. less than about +12 inches (narrow range).

During the event, the lowest reactor vessel water level that occurred was approximately -12 inches (narrow range). This level is significantly greater than the core standby cooling systems set point (approximately

- 46 inches), and the level corresponding to the top of the active fuel zone (approximately -127 inches).

All safety systems performed as designed. This event did not result in a challenge to fuel limits or release of radioactive material above the expected normal operating level. The packing leak on the MO-1 202-85 valve was not an RCS pressure boundary leak. MO-1201-85 is not a containment isolation valve or a reactor pressure vessel isolation valve. The packing leak had no adverse effect on any safety function.

Technical Specification limits for RCS leakage were not exceeded.

The event posed no threat to public health and safety.

REPORTABILITY

This report is submitted in accordance with 10 CFR 50.73(a)(2)(iv)(A) as a condition that generated containment isolation signals affecting containment isolation valves in more than one system.

SIMILARITY TO PREVIOUS EVENTS A review was conducted of Pilgrim Station LERs submitted since 2003. The review focused on similarities involving an automatic or manual scram(s) in response to increased drywell leakage. The review identified no similar events.U.S. NUCLEAR REGULATORY COMMISSION LICENSEE EVENT REPORT (LER)

TEXT CONTINUATION FACILITY NAME (1)

DOCKET NUMBER 2 LER NUMBER (6)

PAGE 3 SEQUENTIAL REVISION YEAR NUMBER NUMBER PILGRIM NUCLEAR POWER STATION 05000-293 2007 001 00 5of5 TEXT (If more space is required, use additional copies of NRC Form 366A) (17)

ENERGY INDUSTRY IDENTIFICATION SYSTEM (EIIS) CODES The EIIS codes for this report are as follows:

COMPONENTS CODES Valve (MO-1201-85)

V SYSTEMS CODES Containment isolation control system (PCIS/RBIS)

JM Engineered safety features actuation system (RPS, PCIS, RBIS)

JE Plant protection system (RPS)

JC Reactor building (SCS)

NG Reactor water cleanup system (RWCU)

CE Standby gas treatment system (SGTS)

BH