ML19208A032

From kanterella
Revision as of 07:11, 2 February 2020 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Forwards LER 79-016/03L-0
ML19208A032
Person / Time
Site: Quad Cities Constellation icon.png
Issue date: 08/21/1979
From: Kalivianakis N
COMMONWEALTH EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML19208A033 List:
References
NJK-79-306, NUDOCS 7909120441
Download: ML19208A032 (1)


Text

, .

- r,>

Ouad Cities Nuclear Power Station h

@ Commonwealth Edison 22710 206 Avenue North Corcova, Illinois 61242 Telephone 309/654-2241 NJK-79-306 August 21, 1979 J. Keppler, Regional Director Office of Inspection and Enforcement Region til U.S. Nuclear Regulatory Commission 799 Rooseve1t Road Glen Ellyn, IL 60137

Reference:

Quad-Cities Nuclear Power Station Docket No. 5'-265, DPR-30, Unit 2 Appendix A, aections Table 3.2-1 and 6.6.B.2.a Enclosed please find Reportable Occurrence Report No. R0 79-16/03L for Quad-Cities Nuclear Power Station. This report is submitted to you in accordance with the requirements of Technical Specification 6.6.B.2.a as an engineered safety feature instrument setting which was found to be less conservative than those established by the Technical Specificotion but which did not prevent the fulfillment of the functional requirement of the affected system.

Very truly yours, COMMONWEALTH EDISON COMPANY QUAD-CITIES NUCLEAR POWER STATION N. J. Kalivianakis Station Superintendent NJ K/JCV/c:nd cc: R. J. Janecek r

', 7J 7 900120//g/ '