Forwards LER 79-016/03L-0
Date released: 08/10/2019 Download: ML19208A033


LER 79-016/03L-0:on 790815,HPCI Turbine Area Temp Switch Found to Trip Above Tech Spec Limits.Caused by Setpoint Drift.Switch Replaced & Tested Satisfactorily
ML19208A045
Person / Time
Site: Quad Cities Constellation icon.png
Issue date: 08/21/1979
From: Vahrenwald J
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19208A045 (1)
Forwards LER 79-016/03L-0
ML19208A032
Person / Time
Site: Quad Cities Constellation icon.png
Issue date: 08/21/1979
From: Kalivianakis N
COMMONWEALTH EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References