ML19257A725: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
 
Line 18: Line 18:
=Text=
=Text=
{{#Wiki_filter:.- ,
{{#Wiki_filter:.- ,
,
Commonwealth Edison Quad Cities Nuclear Power $tation
Commonwealth Edison Quad Cities Nuclear Power $tation
[  b 22710 206 Avenue North Corcova, Illinois 61242 Telephone 309/654-2241 NJK-79-450 December 10, 1979 J. Keppler, Regional Dl rector Office of Inspection and Enforcement Region ilI U.S. Nuclear Regulatory Co.rmission 799 Roosevelt Road Glen Ellyn, Illinois              60137
[  b 22710 206 Avenue North Corcova, Illinois 61242 Telephone 309/654-2241 NJK-79-450 December 10, 1979 J. Keppler, Regional Dl rector Office of Inspection and Enforcement Region ilI U.S. Nuclear Regulatory Co.rmission 799 Roosevelt Road Glen Ellyn, Illinois              60137

Latest revision as of 23:53, 1 February 2020

Forwards LER 79-038/01T-0
ML19257A725
Person / Time
Site: Quad Cities Constellation icon.png
Issue date: 12/10/1979
From: Kalivianakis N
COMMONWEALTH EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML19257A726 List:
References
NUDOCS 8001070471
Download: ML19257A725 (1)


Text

.- ,

Commonwealth Edison Quad Cities Nuclear Power $tation

[ b 22710 206 Avenue North Corcova, Illinois 61242 Telephone 309/654-2241 NJK-79-450 December 10, 1979 J. Keppler, Regional Dl rector Office of Inspection and Enforcement Region ilI U.S. Nuclear Regulatory Co.rmission 799 Roosevelt Road Glen Ellyn, Illinois 60137

Reference:

Quad-Cities Nuclear Power Station Docket No. 50-254, DPR-29, Unit 1 Appendix A, Sections 3 1.A, and 6.6.8.1.1 Enclosed please find Reportable Occurrence Report No. RO 79-38/01T for quad-Cities Nuclear Power Station. This occurrence was previously reported to Region 111, Office of Inspection and Enforcement by telephone and by telecopy on November 28, 1979 This report is submitted to you in accordance with the requirements of Technical Specification 6.6.B. I . i, as components that require corrective measures to prevent operation in a manner less conservative than assumed in the Technical Specification basis.

Very truly yours, COMMONWEALTH EDISON COMPANY QUAD-CITIES NU LEAR POWER STATION -p g

/) l W

[4.CANA^fw N. J . Ka l ivianaki s q6)

Station Superintendent NJ K/JCV/ san cc: R. F. Janecek

\

1693 275 soot ovo Y 7/

S