Text

.- ,

Commonwealth Edison Quad Cities Nuclear Power $tation

[ b 22710 206 Avenue North Corcova, Illinois 61242 Telephone 309/654-2241 NJK-79-450 December 10, 1979 J. Keppler, Regional Dl rector Office of Inspection and Enforcement Region ilI U.S. Nuclear Regulatory Co.rmission 799 Roosevelt Road Glen Ellyn, Illinois 60137

Reference:

Quad-Cities Nuclear Power Station Docket No. 50-254, DPR-29, Unit 1 Appendix A, Sections 3 1.A, and 6.6.8.1.1 Enclosed please find Reportable Occurrence Report No. RO 79-38/01T for quad-Cities Nuclear Power Station. This occurrence was previously reported to Region 111, Office of Inspection and Enforcement by telephone and by telecopy on November 28, 1979 This report is submitted to you in accordance with the requirements of Technical Specification 6.6.B. I . i, as components that require corrective measures to prevent operation in a manner less conservative than assumed in the Technical Specification basis.

Very truly yours, COMMONWEALTH EDISON COMPANY QUAD-CITIES NU LEAR POWER STATION -p g

/) l W

[4.CANA^fw N. J . Ka l ivianaki s q6)

Station Superintendent NJ K/JCV/ san cc: R. F. Janecek

\

1693 275 soot ovo Y 7/