Advises of Mod to 830310 Submittal Re Inadequate Core Cooling.Low Point for delta-pressure Sys Will Tie Into Decay Heat Drop Line Rather than in-core Instrument Tube. Concurrence in Conceptual Design Needed by 830601
ML20073J003
Person / Time
Site: Three Mile Island Constellation icon.png
Issue date: 04/14/1983
From: Hukill H
GENERAL PUBLIC UTILITIES CORP.
To: Eisenhut D
Office of Nuclear Reactor Regulation
References
5211-83-116, NUDOCS 8304190136
Download: ML20073J003 (2)


Text

V c

GPU Nuclear Corporation

. Nuclear

= g g S s8 48o Middletown. Pennsylvania 17057 717 944-7621 TELEX 84-2386 Writer"s Direct Dial Number:

April 14, 1983 5211-83-116 Office of Nucicar Reactor Regulation Attn: D. C. Eisenhut, Director Division of Licensing U. S. Nuclear Regulatory Commission Washington, D.C. 20555 Deer Sir:

Three Mile Island Nuclear Station, Unit 1 (TMI-1)

Operating License No. DPR-50 Docket No. 50-289 Inadequate Core Cooling GPU Nuclear Corporation submitted on March 10, 1983, our response to the

" Order for PSdification of License," dated December 10, 1982, including our proposed approach to monitoring reactor coolant system inventory.

The proposed system for level measurement with pumps turned off utilizes differential pressure measurement from the high points in the system to a location representative of the low point of the hot legs. In the March 10 submittal we indicated that we had tentatively selected a tap into an incore instrument tube for the low point, but that we were continuing to evaluate the relative advantages and disadvantages of that location vs. tie-in to the decay heat drop-line.

We have now completed comparison of these locations. We believe that either would be technically acceptable, and would provide the basis for an inventory trg king system which would meet the NRC requirements. We have concluded, however, that the decay heat drop-line tie-in provides several significant advantages:

1. Tie-in to the incore instrument tube requires removal of that instrument string from the reactor core. Although safe reactor operation is possible with one or more instrument strings out of service, it is desirable to retain as many in operation as possible to monitor the incore conditions. A tie-in to the decay heat drop-line would not require instrumentation to be removed from service.
2. Tie-in to the decay heat drop-line results in a system which we believe would provide better accurtcy in measuring hot leg level. <

iOOl

$q 8304190136 830414 PDR ADOCK 05000289 P PDR GPU Nuclear Corporation is a subsidiary of the General Public Utilities Corporation

t c

Mr. D. G. Eisenhut -2 .

5211-83-116 This is true because temperature compensation is much more simple and induces _less inaccuracy. and also because indication of the water level is unperturbed ~by conditions which.might exist within the core, such as localized boiling.

3, ~ It is our understanding that other B&W Owners are utilizing a delta p system with a tie-in to the decay heat drop-line.- The NRC staff ~has repeatedly urged that B&W owners adopt a common approach'to meeting NRC requirements in order to facilitate the staff review of the proposed approach.'

For the above reasons, we are hereby modifying the approach described in our March.10 submittal so that the low point for the delta-p system is now a tie-in to the decay heat drop-line rather than the incore instrument tube.

Other aspects of the March'10 submittal remain unchanged, including the proposed schedule'for implementation. In order, however, for 6PU Nuclear Corporation -

to meet this implementation schedule, we need your concurrence with our concept-ual design no later than June 1,.1983. .

Sincerely, L 'fis y . kill Director, TMI-l HDH:LWH:vj f cc: ~J. Van Vliet J. Stolz