i GPO Nuclest Cetpetet6en N

r Post Office Fw abo i

Route 441 South Micoletown, Pennsylvania 17057 0191 717 944 7c21 TELEX 64 2366 Writer's Direct Dial Number:

(

March 23,1990 l

C311 90 2034 l

i i

U. $. Nuclear Regulatory Commission Attn: Document Control Desk j

Washington, D. C. 20555 i

Dear sir:

l Three Mile Island Nuclear Station, Unit 1 (TM1-1) f Operating License No. DPR-50 j

Docket No. 50 289 OTSG Tubes Post Inservice Inspection Report i

For Unscheduled Dutage 8U-1 Technical Specification section 4.19.5.a requires reporting to the NRC, within 15 days following the completion of each inservice inspection of steam generator tubes, the number of tubes repaired or removed from service in each j

steam generator.

During the recent unscheduled 8U-1 outage, an eddy current inspection of the DTSG "A" Lane Wedge Area tubes was conducted.

As a result of this inspection, two (2) tubes were removed from service by plugging. The plugging was completed on March 11, 1990.

i i

The scope of this inspection was in accordance with the temporary " Waiver of i

Compliance" from Technical Specification 4.19.3.c. granted by the NRC on l

March 14, 1990.

Since f abrication, a total of 1267 tubes have been removed l

from service in steam generator "A", and 370 tubes in steam generator"B".

l t

This letter fulfills the requirements of Technical Specification Section

~

4.19.5.a.

l i

Sincerely f

9oo41oot50 900323

{

fiDOCK05oo{ig?

F DR A. D. Hukill Vice President and Director, TMI-1 HDH/EP/it R. Hernan (NRC)

T. Martin (NRC)

()4r1 I

F. Young (NRC) g p

)

i l

GPU Nuclear Corporation is a subsidiary of General Pubhc Utshties Corporation

)