ML20058M720

From kanterella
Jump to navigation Jump to search
Forwards Rev 2 to TER 3232-019, Div Technical Evaluation Rept for Processed Water Disposal Sys. Mods Include Elimination of Pelletizer & Relocation of Druming Station to Discharge of Blender/Dryer
ML20058M720
Person / Time
Site: Crane 
Issue date: 08/03/1990
From: Long R
GENERAL PUBLIC UTILITIES CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20058M723 List:
References
4410-90-L-0059, 4410-90-L-59, C-90-1031, C000-90-1031, NUDOCS 9008100326
Download: ML20058M720 (1)


Text

,

j e

L GPU Nucloor Corporation j

l ay One Upper Pond Road L

1-Wu Parsippany, New Jersey 07054 2o1 316-7000 l

l TELEX 136 482 Writer's Direct Dial Number.

(201) 316-74B4 C000-90-1031 4410-90-L-0059 1

4 August 3, 1990 j

US Nuclear Regulatory Commission Washington, DC 20L5 Attention:

Document Control Desk L

SUBJECT:

Three Mile Island Nuclear Station, Unit 2 (TMI-2)

Operating License No. DPR-73 i

L Docket No.'50-320 j

L Processed Water Disposal System Technical Evaluation Report, Rev. 2 1

Dear Sirs:

)

1 Encloss.: for your information is Revision 2 to the Processed Water Disposal System Technical Evaluation Report (Evaporator TER). This revision describes the modifications to the evaporator as well as changes to system operating parameters made as a result of system acceptance testing. These modifications include elimination of the Pelletizer, relocation of the drumming station to the discharge of the blender / dryer, addition of a cyclonic moisture separator i

to the stack, and var sous minor changes to system operating parameters, l-predominantly flow rate and solids concentrations. These changes do not modify previous commitments with respect to system effluents and operational performance, i.e., Decnntamination Factor greater than 1000. Therefore, we are proceeding with the moc,*ications and plan to initiate Accident Generated Water o

l' disposal by. evaporation upon NRC approval of the evaporator operating procedures in accordance with TMI-2 Technical Specification 3.9.13.

i l

Sincerely Yours,

!?

~

b Robert. L. Long gg{

Director, Corporate Services /

- (c o Director, TMId 8R So JJB:mkk

ov M8 Enclosure co-cc:

T. T. Martin - Regional Administrator, Region I

[ 0g L

J. F. Stolz - Director, Plant Directorate IV H. Thonus - Project Manager, TMI Site oc" 0000n'L

' F. I. Young - Senior Resident Inspector, TMI i

i g

GPU Nuclear Corporation is a subsdary of General Public Utdities Corporation

-