Insp Repts 50-254/90-08 & 50-265/90-08 on 900429-0616.No Violations Noted.Major Areas Inspected:Licensee Action on Previously Identified Items,Ler Review,Operational Safety Verification & Monthly Maint ObservationML20044A993 |
Person / Time |
---|
Site: |
Quad Cities |
---|
Issue date: |
07/11/1990 |
---|
From: |
Hinds J NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
---|
To: |
|
---|
Shared Package |
---|
ML20044A991 |
List: |
---|
References |
---|
50-254-90-08, 50-254-90-8, 50-265-90-08, 50-265-90-8, NUDOCS 9007170138 |
Download: ML20044A993 (10) |
|
|
---|
Category:INSPECTION REPORT
MONTHYEARIR 05000254/19990171999-09-15015 September 1999 Insp Repts 50-254/99-17 & 50-265/99-17 on 990823-27.No Violations Noted.Major Areas Inspected:Pilot Baseline Insp for Annual Review of Changes to Safety Analysis Rept & Biennial Review Permanent Plant Mod IR 05000254/19990151999-08-25025 August 1999 Insp Repts 50-254/99-15 & 50-265/99-15 on 990816-20.No Violations Noted.Major Areas Inspected:Maint Rule Implementation IR 05000254/19990101999-08-20020 August 1999 Insp Repts 50-254/99-10,50-265/99-10,50-454/99-09, 50-455/99-09,50-456/99-10 & 50-457/99-10 on 990628-0721. Major Areas Inspected:Licensee C/A Approach & Implementation of Configuration Control Processes at Each Site IR 05000254/19990161999-08-19019 August 1999 Insp Repts 50-254/99-16 & 50-265/99-16 on 990719-22. Violations Noted.Major Areas Inspected:Physical Protection Cornerstone,Including Review of Access Authoization Program & Changes to Security Plan IR 05000254/19990121999-08-13013 August 1999 Insp Repts 50-254/99-12 & 50-265/99-12 on 990628-0716. Violations Noted.Major Areas Inspected:Corrective Action Process Which Included Methods Used for Identification, Cause Investigation & Correction of Quality Related Items IR 05000254/19990111999-08-13013 August 1999 Insp Repts 50-254/99-11 & 50-265/99-11 on 990601-0720.NCVs Noted.Major Areas Inspected:Performance in Initiating Events,Mitigating Sys,Barrier Integrity Cornerstones & Performance Indicator Verification IR 05000254/19990141999-07-30030 July 1999 Insp Repts 50-254/99-14 & 50-265/99-14 on 990713-15.One Violation Noted & Treated as Ncv.Major Areas Inspected: Heat Sink Performance,Which Covers Inspectable Area Under Initiating Events & Mitigation Sys IR 05000254/19990131999-07-29029 July 1999 Insp Repts 50-254/99-13 & 50-265/99-13 on 990628-0702.No Violations Noted.Major Areas Inspected:Public Radiation Safety & Review of Gaseous & Liquid Radiological Effluents & of Radiological Environmental Monitoring Program IR 05000254/19990091999-06-23023 June 1999 Insp Repts 50-254/99-09 & 50-265/99-09 on 990421-0531.One Violation of NRC Requirements Occurred & Being Treated as non-cited Violation.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000254/19990061999-05-14014 May 1999 Insp Repts 50-254/99-06 & 50-265/99-06 on 990307-0420.Three Violations Noted & Being Treated as non-cited Violations. Major Areas Insptected:Aspects of Licensee Operations,Maint, Engineering & Plant Support IR 05000254/19990081999-05-11011 May 1999 Insp Repts 50-254/99-08 & 50-265/99-08 on 990419-23.No Violations Noted.Major Areas Inspected:Adequacy of Licensee Programs,Procedures,Training & Supporting Documentation IR 05000254/19990031999-04-0909 April 1999 Insp Repts 50-254/99-03 & 50-265/99-03 on 990308-12.No Violations Noted.Major Areas Inspected:Maint & Engineering IR 05000254/19990011999-04-0101 April 1999 Insp Repts 50-254/99-01 & 50-265/99-01 on 990121-0306. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000254/19990071999-03-31031 March 1999 Radiation Protection Insp Repts 50-254/99-07 & 50-265/99-07 on 990309-12.No Violations Noted.Major Areas Inspected:Solid Radwaste Processing & Control Program & Radioactive Matls Shipping Program IR 05000254/19980211999-03-0505 March 1999 Insp Repts 50-254/98-21 & 50-265/98-21 on 981112-1218. Violation Noted:Major Areas Inspected:Isi Activities at Plant During Refueling Outage 15 IR 05000254/19990041999-02-26026 February 1999 Insp Repts 50-254/99-04 & 50-265/99-04 on 990201-05.No Violations Noted.Major Areas Inspected:Emergency Prepardeness Program as Aspect of Plant Support IR 05000254/19990021999-02-25025 February 1999 Insp Repts 50-254/99-02 & 50-265/99-02 on 990125-29.No Violations Noted.Major Areas Inspected:Radiation Protection & Chemistry Program Included Water Chemistry Control, Instrument Quality Control & internal-lab Comparison IR 05000254/19980241999-01-14014 January 1999 Partially Withheld Security Insp Repts 50-254/98-24 & 50-265/98-24.Violations Noted.Major Areas Inspected:Plant Support Activities Re Physical Protection of Quad Cities Facility.Details Withheld (Ref 10CFR2.790) IR 05000254/19980221998-12-28028 December 1998 Insp Repts 50-254/98-22 & 50-265/98-22 on 981130-1204.No Violations Noted.Major Areas Inspected:Radiation Protection Staff Preparation for Q1R15 Refueling Outage,Including Review of ALARA Planning & Work Plan Integration IR 05000254/19980201998-12-28028 December 1998 Insp Repts 50-254/98-20 & 50-265/98-20 on 981014-1201.No Violations Noted.Major Areas Inspected:Operations,Maint & Plant Support IR 05000254/19980191998-12-18018 December 1998 Insp Repts 50-254/98-19 & 50-265/98-19 on 981019-1106. Violations Noted.Major Areas Inspected:Effectiveness of Engineering & Technical Support Provided to Plant in Performance of Routine & Reactive Site Activities IR 05000254/19980171998-11-0505 November 1998 Insp Repts 50-254/98-17 & 50-265/98-17 on 980902-1014.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000254/19980181998-10-15015 October 1998 Partially Withheld Insp Repts 50-254/98-18 & 50-265/98-18 on 980914-18 (Ref 10CFR73.71).No Violations Identified.Major Areas Inspected:Review of Plant Support Activities,Security Activities Re Onsite Personnel Access & Communications IR 05000254/19980131998-09-22022 September 1998 Insp Repts 50-254/98-13 & 50-265/98-13 on 980716-0901.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000254/19980141998-09-17017 September 1998 Insp Repts 50-254/98-14 & 50-265/98-14 on 980825-28.No Violations Noted.Major Areas Inspected:Evaluation of Licensee Performance During Plant Biennial Exercise of Emergency Plan IR 05000254/19980161998-09-0404 September 1998 Insp Repts 50-254/98-16 & 50-265/98-16 on 980810-14.No Violations Noted.Major Areas Inspected:Radiation Protection Program Included External & Internal Exposure Control,Whole Body Counting & Contamination & Survey Monitoring Program IR 05000254/19980151998-07-31031 July 1998 Insp Repts 50-254/98-15 & 50-265/98-15 on 980721-24.No Violations Noted.Major Areas Inspected:Aspects of Licensee Corrective Actions & Engineering Involvement in Corrective Actions Process IR 05000254/19980111998-07-0202 July 1998 Insp Repts 50-254/98-11 & 50-265/98-11 on 980504-22. Violations Noted.Major Areas Inspected:Quad Cities Safe Shutdown Analysis & Supporting Procedures IR 05000254/19980081998-05-11011 May 1998 Insp Repts 50-254/98-08 & 50-265/98-08 on 980407-09 & 14-17. No Violations Noted.Major Areas Inspected:Maint,Quality Assurance & Engineering IR 05000254/19982011998-05-0606 May 1998 Insp Repts 50-254/98-201 & 50-265/98-201 on 980216-0327.No Violations Noted.Major Areas Inspected:Evaluation of Capability of Selected Sys to Perform Safety Functions Required by Design Bases IR 05000254/19980101998-05-0606 May 1998 Insp Repts 50-254/98-10 & 50-265/98-10 on 980413-17.No Violations Noted.Major Areas Inspected:Liquid & Gaseous Effluent Programs,Annual Effluent Rept,Continuous Air & Area Radiation Monitors IR 05000254/19980051998-04-23023 April 1998 Insp Repts 50-254/98-05 & 50-265/98-05 on 980216-0326. Violations Noted.Major Areas Inspected:Engineering,Including Allowances for Development of Emergency & Immediate Mods ML20217G3401998-04-23023 April 1998 Insp Repts 50-254/98-04 & 50-265/98-04 on 980211-0331. Violations Noted.Major Areas Inspected:Operations, Engineering,Maint & Plant Support IR 05000254/19980071998-04-22022 April 1998 Insp Repts 50-254/98-07 & 50-265/98-07 on 980330-0403.No Violations Noted.Major Areas Inspected:Plant Support Activities Re Physical Protection of Plant,Adequacy of Security Procedures & Event Logs ML20216C2601998-03-0606 March 1998 Insp Repts 50-254/97-28 & 50-265/97-28 on 971224-980210. Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000254/19970221998-02-13013 February 1998 Insp Repts 50-254/97-22 & 50-265/97-22 on 971027-1121. Violations Noted.Major Areas Inspected:Hpci Sys Operational Performance for Operations,Maintenance & Engineering IR 05000254/19980021998-02-0505 February 1998 Insp Repts 50-254/98-02 & 50-265/98-02 on 980112-16. Violations Noted.Major Areas Inspected:Review of ALARA Planning,Radiation Work Permits & Observations of Radworker Performance IR 05000254/19970261998-01-21021 January 1998 Insp Repts 50-254/97-26 & 50-265/97-26 on 971103-1223. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000254/19970241998-01-13013 January 1998 Insp Repts 50-254/97-24 & 50-265/97-24 on 971124-1202.No Violations Noted.Major Areas Inspected:Licensed RO & SRO Requalification Training Programs ML20197F5741997-12-23023 December 1997 Insp Repts 50-254/97-27 & 50-265/97-27 on 971103-07 & 1204. Violations Noted.Major Areas Inspected:Maint & Engineering IR 05000254/19970141997-12-16016 December 1997 Insp Repts 50-254/97-14 & 50-265/97-14 on 970729-0922.NOV & Deviations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support Re Troubleshooting Resulting in Discovery of Long Standing Problem W/Fire Pump IR 05000254/19970211997-12-0909 December 1997 Insp Repts 50-254/97-21 & 50-265/97-21 on 970923-1103.No Violations Noted.Major Areas Inspected:Operation,Maint, Engineering & Plant Support IR 05000254/19970251997-12-0909 December 1997 Insp Repts 50-254/97-25 & 50-265/97-25 on 971103-07.No Violations Noted.Major Areas Inspected:Respiratory Protection Plan,Source Term Reduction Efforts & Follow Up on Several Open Items IR 05000254/19970191997-11-18018 November 1997 Insp Repts 50-254/97-19 & 50-265/97-19 on 971006-10.No Violations Noted.Major Areas Inspected:Ep Program IR 05000254/19970181997-11-10010 November 1997 Insp Repts 50-254/97-18 & 50-265/97-18 on 970922-25. Violations Noted.Major Areas Inspected:Maintenance & Engineering IR 05000254/19970161997-11-0505 November 1997 Insp Repts 50-254/97-16 & 50-265/97-16 on 970825-29. Violations Noted.Major Areas Inspected:Fire Protection Program & Several App R Issues IR 05000254/19970201997-10-25025 October 1997 Insp Repts 50-254/97-20 & 50-265/97-20 on 970929-1002.No Violations Noted.Major Areas Inspected:Quality of Security Related Audits,Reviewed Effectiveness of Mgt Controls & Verified Performance of Protected Area Control Activities IR 05000254/19970151997-09-0303 September 1997 Insp Repts 50-254/97-15 & 50-265/97-15 on 970811-14.No Violations Noted.Major Areas Inspected:Station Chemistry & REMP IR 05000254/19970121997-07-31031 July 1997 Insp Repts 50-254/97-12 & 50-265/97-12 on 970707-16.No Violations Noted.Major Areas Inspected:Review of Plant Support Activities Re Physical Protection of Facility & Corrective Actions to Security Issues IR 05000254/19970081997-07-11011 July 1997 Insp Repts 50-254/97-08 & 50-265/97-08 on 970506-0616. Violations Noted.Major Areas Inspected:Operations,Maint & Surveillance,Engineering & Plant Support 1999-09-15
[Table view] Category:NRC-GENERATED
MONTHYEARIR 05000254/19990171999-09-15015 September 1999 Insp Repts 50-254/99-17 & 50-265/99-17 on 990823-27.No Violations Noted.Major Areas Inspected:Pilot Baseline Insp for Annual Review of Changes to Safety Analysis Rept & Biennial Review Permanent Plant Mod IR 05000254/19990151999-08-25025 August 1999 Insp Repts 50-254/99-15 & 50-265/99-15 on 990816-20.No Violations Noted.Major Areas Inspected:Maint Rule Implementation IR 05000254/19990101999-08-20020 August 1999 Insp Repts 50-254/99-10,50-265/99-10,50-454/99-09, 50-455/99-09,50-456/99-10 & 50-457/99-10 on 990628-0721. Major Areas Inspected:Licensee C/A Approach & Implementation of Configuration Control Processes at Each Site IR 05000254/19990161999-08-19019 August 1999 Insp Repts 50-254/99-16 & 50-265/99-16 on 990719-22. Violations Noted.Major Areas Inspected:Physical Protection Cornerstone,Including Review of Access Authoization Program & Changes to Security Plan IR 05000254/19990121999-08-13013 August 1999 Insp Repts 50-254/99-12 & 50-265/99-12 on 990628-0716. Violations Noted.Major Areas Inspected:Corrective Action Process Which Included Methods Used for Identification, Cause Investigation & Correction of Quality Related Items IR 05000254/19990111999-08-13013 August 1999 Insp Repts 50-254/99-11 & 50-265/99-11 on 990601-0720.NCVs Noted.Major Areas Inspected:Performance in Initiating Events,Mitigating Sys,Barrier Integrity Cornerstones & Performance Indicator Verification IR 05000254/19990141999-07-30030 July 1999 Insp Repts 50-254/99-14 & 50-265/99-14 on 990713-15.One Violation Noted & Treated as Ncv.Major Areas Inspected: Heat Sink Performance,Which Covers Inspectable Area Under Initiating Events & Mitigation Sys IR 05000254/19990131999-07-29029 July 1999 Insp Repts 50-254/99-13 & 50-265/99-13 on 990628-0702.No Violations Noted.Major Areas Inspected:Public Radiation Safety & Review of Gaseous & Liquid Radiological Effluents & of Radiological Environmental Monitoring Program IR 05000254/19990091999-06-23023 June 1999 Insp Repts 50-254/99-09 & 50-265/99-09 on 990421-0531.One Violation of NRC Requirements Occurred & Being Treated as non-cited Violation.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000254/19990061999-05-14014 May 1999 Insp Repts 50-254/99-06 & 50-265/99-06 on 990307-0420.Three Violations Noted & Being Treated as non-cited Violations. Major Areas Insptected:Aspects of Licensee Operations,Maint, Engineering & Plant Support IR 05000254/19990081999-05-11011 May 1999 Insp Repts 50-254/99-08 & 50-265/99-08 on 990419-23.No Violations Noted.Major Areas Inspected:Adequacy of Licensee Programs,Procedures,Training & Supporting Documentation IR 05000254/19990031999-04-0909 April 1999 Insp Repts 50-254/99-03 & 50-265/99-03 on 990308-12.No Violations Noted.Major Areas Inspected:Maint & Engineering IR 05000254/19990011999-04-0101 April 1999 Insp Repts 50-254/99-01 & 50-265/99-01 on 990121-0306. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000254/19990071999-03-31031 March 1999 Radiation Protection Insp Repts 50-254/99-07 & 50-265/99-07 on 990309-12.No Violations Noted.Major Areas Inspected:Solid Radwaste Processing & Control Program & Radioactive Matls Shipping Program IR 05000254/19980211999-03-0505 March 1999 Insp Repts 50-254/98-21 & 50-265/98-21 on 981112-1218. Violation Noted:Major Areas Inspected:Isi Activities at Plant During Refueling Outage 15 IR 05000254/19990041999-02-26026 February 1999 Insp Repts 50-254/99-04 & 50-265/99-04 on 990201-05.No Violations Noted.Major Areas Inspected:Emergency Prepardeness Program as Aspect of Plant Support IR 05000254/19990021999-02-25025 February 1999 Insp Repts 50-254/99-02 & 50-265/99-02 on 990125-29.No Violations Noted.Major Areas Inspected:Radiation Protection & Chemistry Program Included Water Chemistry Control, Instrument Quality Control & internal-lab Comparison IR 05000254/19980241999-01-14014 January 1999 Partially Withheld Security Insp Repts 50-254/98-24 & 50-265/98-24.Violations Noted.Major Areas Inspected:Plant Support Activities Re Physical Protection of Quad Cities Facility.Details Withheld (Ref 10CFR2.790) IR 05000254/19980221998-12-28028 December 1998 Insp Repts 50-254/98-22 & 50-265/98-22 on 981130-1204.No Violations Noted.Major Areas Inspected:Radiation Protection Staff Preparation for Q1R15 Refueling Outage,Including Review of ALARA Planning & Work Plan Integration IR 05000254/19980201998-12-28028 December 1998 Insp Repts 50-254/98-20 & 50-265/98-20 on 981014-1201.No Violations Noted.Major Areas Inspected:Operations,Maint & Plant Support IR 05000254/19980191998-12-18018 December 1998 Insp Repts 50-254/98-19 & 50-265/98-19 on 981019-1106. Violations Noted.Major Areas Inspected:Effectiveness of Engineering & Technical Support Provided to Plant in Performance of Routine & Reactive Site Activities IR 05000254/19980171998-11-0505 November 1998 Insp Repts 50-254/98-17 & 50-265/98-17 on 980902-1014.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000254/19980181998-10-15015 October 1998 Partially Withheld Insp Repts 50-254/98-18 & 50-265/98-18 on 980914-18 (Ref 10CFR73.71).No Violations Identified.Major Areas Inspected:Review of Plant Support Activities,Security Activities Re Onsite Personnel Access & Communications IR 05000254/19980131998-09-22022 September 1998 Insp Repts 50-254/98-13 & 50-265/98-13 on 980716-0901.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000254/19980141998-09-17017 September 1998 Insp Repts 50-254/98-14 & 50-265/98-14 on 980825-28.No Violations Noted.Major Areas Inspected:Evaluation of Licensee Performance During Plant Biennial Exercise of Emergency Plan IR 05000254/19980161998-09-0404 September 1998 Insp Repts 50-254/98-16 & 50-265/98-16 on 980810-14.No Violations Noted.Major Areas Inspected:Radiation Protection Program Included External & Internal Exposure Control,Whole Body Counting & Contamination & Survey Monitoring Program IR 05000254/19980151998-07-31031 July 1998 Insp Repts 50-254/98-15 & 50-265/98-15 on 980721-24.No Violations Noted.Major Areas Inspected:Aspects of Licensee Corrective Actions & Engineering Involvement in Corrective Actions Process IR 05000254/19980111998-07-0202 July 1998 Insp Repts 50-254/98-11 & 50-265/98-11 on 980504-22. Violations Noted.Major Areas Inspected:Quad Cities Safe Shutdown Analysis & Supporting Procedures IR 05000254/19980081998-05-11011 May 1998 Insp Repts 50-254/98-08 & 50-265/98-08 on 980407-09 & 14-17. No Violations Noted.Major Areas Inspected:Maint,Quality Assurance & Engineering IR 05000254/19982011998-05-0606 May 1998 Insp Repts 50-254/98-201 & 50-265/98-201 on 980216-0327.No Violations Noted.Major Areas Inspected:Evaluation of Capability of Selected Sys to Perform Safety Functions Required by Design Bases IR 05000254/19980101998-05-0606 May 1998 Insp Repts 50-254/98-10 & 50-265/98-10 on 980413-17.No Violations Noted.Major Areas Inspected:Liquid & Gaseous Effluent Programs,Annual Effluent Rept,Continuous Air & Area Radiation Monitors IR 05000254/19980051998-04-23023 April 1998 Insp Repts 50-254/98-05 & 50-265/98-05 on 980216-0326. Violations Noted.Major Areas Inspected:Engineering,Including Allowances for Development of Emergency & Immediate Mods ML20217G3401998-04-23023 April 1998 Insp Repts 50-254/98-04 & 50-265/98-04 on 980211-0331. Violations Noted.Major Areas Inspected:Operations, Engineering,Maint & Plant Support IR 05000254/19980071998-04-22022 April 1998 Insp Repts 50-254/98-07 & 50-265/98-07 on 980330-0403.No Violations Noted.Major Areas Inspected:Plant Support Activities Re Physical Protection of Plant,Adequacy of Security Procedures & Event Logs ML20216C2601998-03-0606 March 1998 Insp Repts 50-254/97-28 & 50-265/97-28 on 971224-980210. Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000254/19970221998-02-13013 February 1998 Insp Repts 50-254/97-22 & 50-265/97-22 on 971027-1121. Violations Noted.Major Areas Inspected:Hpci Sys Operational Performance for Operations,Maintenance & Engineering IR 05000254/19980021998-02-0505 February 1998 Insp Repts 50-254/98-02 & 50-265/98-02 on 980112-16. Violations Noted.Major Areas Inspected:Review of ALARA Planning,Radiation Work Permits & Observations of Radworker Performance IR 05000254/19970261998-01-21021 January 1998 Insp Repts 50-254/97-26 & 50-265/97-26 on 971103-1223. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000254/19970241998-01-13013 January 1998 Insp Repts 50-254/97-24 & 50-265/97-24 on 971124-1202.No Violations Noted.Major Areas Inspected:Licensed RO & SRO Requalification Training Programs ML20197F5741997-12-23023 December 1997 Insp Repts 50-254/97-27 & 50-265/97-27 on 971103-07 & 1204. Violations Noted.Major Areas Inspected:Maint & Engineering IR 05000254/19970141997-12-16016 December 1997 Insp Repts 50-254/97-14 & 50-265/97-14 on 970729-0922.NOV & Deviations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support Re Troubleshooting Resulting in Discovery of Long Standing Problem W/Fire Pump IR 05000254/19970211997-12-0909 December 1997 Insp Repts 50-254/97-21 & 50-265/97-21 on 970923-1103.No Violations Noted.Major Areas Inspected:Operation,Maint, Engineering & Plant Support IR 05000254/19970251997-12-0909 December 1997 Insp Repts 50-254/97-25 & 50-265/97-25 on 971103-07.No Violations Noted.Major Areas Inspected:Respiratory Protection Plan,Source Term Reduction Efforts & Follow Up on Several Open Items IR 05000254/19970191997-11-18018 November 1997 Insp Repts 50-254/97-19 & 50-265/97-19 on 971006-10.No Violations Noted.Major Areas Inspected:Ep Program IR 05000254/19970181997-11-10010 November 1997 Insp Repts 50-254/97-18 & 50-265/97-18 on 970922-25. Violations Noted.Major Areas Inspected:Maintenance & Engineering IR 05000254/19970161997-11-0505 November 1997 Insp Repts 50-254/97-16 & 50-265/97-16 on 970825-29. Violations Noted.Major Areas Inspected:Fire Protection Program & Several App R Issues IR 05000254/19970201997-10-25025 October 1997 Insp Repts 50-254/97-20 & 50-265/97-20 on 970929-1002.No Violations Noted.Major Areas Inspected:Quality of Security Related Audits,Reviewed Effectiveness of Mgt Controls & Verified Performance of Protected Area Control Activities IR 05000254/19970151997-09-0303 September 1997 Insp Repts 50-254/97-15 & 50-265/97-15 on 970811-14.No Violations Noted.Major Areas Inspected:Station Chemistry & REMP IR 05000254/19970121997-07-31031 July 1997 Insp Repts 50-254/97-12 & 50-265/97-12 on 970707-16.No Violations Noted.Major Areas Inspected:Review of Plant Support Activities Re Physical Protection of Facility & Corrective Actions to Security Issues IR 05000254/19970081997-07-11011 July 1997 Insp Repts 50-254/97-08 & 50-265/97-08 on 970506-0616. Violations Noted.Major Areas Inspected:Operations,Maint & Surveillance,Engineering & Plant Support 1999-09-15
[Table view] Category:INSPECTION REPORT
MONTHYEARIR 05000254/19990171999-09-15015 September 1999 Insp Repts 50-254/99-17 & 50-265/99-17 on 990823-27.No Violations Noted.Major Areas Inspected:Pilot Baseline Insp for Annual Review of Changes to Safety Analysis Rept & Biennial Review Permanent Plant Mod IR 05000254/19990151999-08-25025 August 1999 Insp Repts 50-254/99-15 & 50-265/99-15 on 990816-20.No Violations Noted.Major Areas Inspected:Maint Rule Implementation IR 05000254/19990101999-08-20020 August 1999 Insp Repts 50-254/99-10,50-265/99-10,50-454/99-09, 50-455/99-09,50-456/99-10 & 50-457/99-10 on 990628-0721. Major Areas Inspected:Licensee C/A Approach & Implementation of Configuration Control Processes at Each Site IR 05000254/19990161999-08-19019 August 1999 Insp Repts 50-254/99-16 & 50-265/99-16 on 990719-22. Violations Noted.Major Areas Inspected:Physical Protection Cornerstone,Including Review of Access Authoization Program & Changes to Security Plan IR 05000254/19990121999-08-13013 August 1999 Insp Repts 50-254/99-12 & 50-265/99-12 on 990628-0716. Violations Noted.Major Areas Inspected:Corrective Action Process Which Included Methods Used for Identification, Cause Investigation & Correction of Quality Related Items IR 05000254/19990111999-08-13013 August 1999 Insp Repts 50-254/99-11 & 50-265/99-11 on 990601-0720.NCVs Noted.Major Areas Inspected:Performance in Initiating Events,Mitigating Sys,Barrier Integrity Cornerstones & Performance Indicator Verification IR 05000254/19990141999-07-30030 July 1999 Insp Repts 50-254/99-14 & 50-265/99-14 on 990713-15.One Violation Noted & Treated as Ncv.Major Areas Inspected: Heat Sink Performance,Which Covers Inspectable Area Under Initiating Events & Mitigation Sys IR 05000254/19990131999-07-29029 July 1999 Insp Repts 50-254/99-13 & 50-265/99-13 on 990628-0702.No Violations Noted.Major Areas Inspected:Public Radiation Safety & Review of Gaseous & Liquid Radiological Effluents & of Radiological Environmental Monitoring Program IR 05000254/19990091999-06-23023 June 1999 Insp Repts 50-254/99-09 & 50-265/99-09 on 990421-0531.One Violation of NRC Requirements Occurred & Being Treated as non-cited Violation.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000254/19990061999-05-14014 May 1999 Insp Repts 50-254/99-06 & 50-265/99-06 on 990307-0420.Three Violations Noted & Being Treated as non-cited Violations. Major Areas Insptected:Aspects of Licensee Operations,Maint, Engineering & Plant Support IR 05000254/19990081999-05-11011 May 1999 Insp Repts 50-254/99-08 & 50-265/99-08 on 990419-23.No Violations Noted.Major Areas Inspected:Adequacy of Licensee Programs,Procedures,Training & Supporting Documentation IR 05000254/19990031999-04-0909 April 1999 Insp Repts 50-254/99-03 & 50-265/99-03 on 990308-12.No Violations Noted.Major Areas Inspected:Maint & Engineering IR 05000254/19990011999-04-0101 April 1999 Insp Repts 50-254/99-01 & 50-265/99-01 on 990121-0306. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000254/19990071999-03-31031 March 1999 Radiation Protection Insp Repts 50-254/99-07 & 50-265/99-07 on 990309-12.No Violations Noted.Major Areas Inspected:Solid Radwaste Processing & Control Program & Radioactive Matls Shipping Program IR 05000254/19980211999-03-0505 March 1999 Insp Repts 50-254/98-21 & 50-265/98-21 on 981112-1218. Violation Noted:Major Areas Inspected:Isi Activities at Plant During Refueling Outage 15 IR 05000254/19990041999-02-26026 February 1999 Insp Repts 50-254/99-04 & 50-265/99-04 on 990201-05.No Violations Noted.Major Areas Inspected:Emergency Prepardeness Program as Aspect of Plant Support IR 05000254/19990021999-02-25025 February 1999 Insp Repts 50-254/99-02 & 50-265/99-02 on 990125-29.No Violations Noted.Major Areas Inspected:Radiation Protection & Chemistry Program Included Water Chemistry Control, Instrument Quality Control & internal-lab Comparison IR 05000254/19980241999-01-14014 January 1999 Partially Withheld Security Insp Repts 50-254/98-24 & 50-265/98-24.Violations Noted.Major Areas Inspected:Plant Support Activities Re Physical Protection of Quad Cities Facility.Details Withheld (Ref 10CFR2.790) IR 05000254/19980221998-12-28028 December 1998 Insp Repts 50-254/98-22 & 50-265/98-22 on 981130-1204.No Violations Noted.Major Areas Inspected:Radiation Protection Staff Preparation for Q1R15 Refueling Outage,Including Review of ALARA Planning & Work Plan Integration IR 05000254/19980201998-12-28028 December 1998 Insp Repts 50-254/98-20 & 50-265/98-20 on 981014-1201.No Violations Noted.Major Areas Inspected:Operations,Maint & Plant Support IR 05000254/19980191998-12-18018 December 1998 Insp Repts 50-254/98-19 & 50-265/98-19 on 981019-1106. Violations Noted.Major Areas Inspected:Effectiveness of Engineering & Technical Support Provided to Plant in Performance of Routine & Reactive Site Activities IR 05000254/19980171998-11-0505 November 1998 Insp Repts 50-254/98-17 & 50-265/98-17 on 980902-1014.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000254/19980181998-10-15015 October 1998 Partially Withheld Insp Repts 50-254/98-18 & 50-265/98-18 on 980914-18 (Ref 10CFR73.71).No Violations Identified.Major Areas Inspected:Review of Plant Support Activities,Security Activities Re Onsite Personnel Access & Communications IR 05000254/19980131998-09-22022 September 1998 Insp Repts 50-254/98-13 & 50-265/98-13 on 980716-0901.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000254/19980141998-09-17017 September 1998 Insp Repts 50-254/98-14 & 50-265/98-14 on 980825-28.No Violations Noted.Major Areas Inspected:Evaluation of Licensee Performance During Plant Biennial Exercise of Emergency Plan IR 05000254/19980161998-09-0404 September 1998 Insp Repts 50-254/98-16 & 50-265/98-16 on 980810-14.No Violations Noted.Major Areas Inspected:Radiation Protection Program Included External & Internal Exposure Control,Whole Body Counting & Contamination & Survey Monitoring Program IR 05000254/19980151998-07-31031 July 1998 Insp Repts 50-254/98-15 & 50-265/98-15 on 980721-24.No Violations Noted.Major Areas Inspected:Aspects of Licensee Corrective Actions & Engineering Involvement in Corrective Actions Process IR 05000254/19980111998-07-0202 July 1998 Insp Repts 50-254/98-11 & 50-265/98-11 on 980504-22. Violations Noted.Major Areas Inspected:Quad Cities Safe Shutdown Analysis & Supporting Procedures IR 05000254/19980081998-05-11011 May 1998 Insp Repts 50-254/98-08 & 50-265/98-08 on 980407-09 & 14-17. No Violations Noted.Major Areas Inspected:Maint,Quality Assurance & Engineering IR 05000254/19982011998-05-0606 May 1998 Insp Repts 50-254/98-201 & 50-265/98-201 on 980216-0327.No Violations Noted.Major Areas Inspected:Evaluation of Capability of Selected Sys to Perform Safety Functions Required by Design Bases IR 05000254/19980101998-05-0606 May 1998 Insp Repts 50-254/98-10 & 50-265/98-10 on 980413-17.No Violations Noted.Major Areas Inspected:Liquid & Gaseous Effluent Programs,Annual Effluent Rept,Continuous Air & Area Radiation Monitors IR 05000254/19980051998-04-23023 April 1998 Insp Repts 50-254/98-05 & 50-265/98-05 on 980216-0326. Violations Noted.Major Areas Inspected:Engineering,Including Allowances for Development of Emergency & Immediate Mods ML20217G3401998-04-23023 April 1998 Insp Repts 50-254/98-04 & 50-265/98-04 on 980211-0331. Violations Noted.Major Areas Inspected:Operations, Engineering,Maint & Plant Support IR 05000254/19980071998-04-22022 April 1998 Insp Repts 50-254/98-07 & 50-265/98-07 on 980330-0403.No Violations Noted.Major Areas Inspected:Plant Support Activities Re Physical Protection of Plant,Adequacy of Security Procedures & Event Logs ML20216C2601998-03-0606 March 1998 Insp Repts 50-254/97-28 & 50-265/97-28 on 971224-980210. Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000254/19970221998-02-13013 February 1998 Insp Repts 50-254/97-22 & 50-265/97-22 on 971027-1121. Violations Noted.Major Areas Inspected:Hpci Sys Operational Performance for Operations,Maintenance & Engineering IR 05000254/19980021998-02-0505 February 1998 Insp Repts 50-254/98-02 & 50-265/98-02 on 980112-16. Violations Noted.Major Areas Inspected:Review of ALARA Planning,Radiation Work Permits & Observations of Radworker Performance IR 05000254/19970261998-01-21021 January 1998 Insp Repts 50-254/97-26 & 50-265/97-26 on 971103-1223. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000254/19970241998-01-13013 January 1998 Insp Repts 50-254/97-24 & 50-265/97-24 on 971124-1202.No Violations Noted.Major Areas Inspected:Licensed RO & SRO Requalification Training Programs ML20197F5741997-12-23023 December 1997 Insp Repts 50-254/97-27 & 50-265/97-27 on 971103-07 & 1204. Violations Noted.Major Areas Inspected:Maint & Engineering IR 05000254/19970141997-12-16016 December 1997 Insp Repts 50-254/97-14 & 50-265/97-14 on 970729-0922.NOV & Deviations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support Re Troubleshooting Resulting in Discovery of Long Standing Problem W/Fire Pump IR 05000254/19970211997-12-0909 December 1997 Insp Repts 50-254/97-21 & 50-265/97-21 on 970923-1103.No Violations Noted.Major Areas Inspected:Operation,Maint, Engineering & Plant Support IR 05000254/19970251997-12-0909 December 1997 Insp Repts 50-254/97-25 & 50-265/97-25 on 971103-07.No Violations Noted.Major Areas Inspected:Respiratory Protection Plan,Source Term Reduction Efforts & Follow Up on Several Open Items IR 05000254/19970191997-11-18018 November 1997 Insp Repts 50-254/97-19 & 50-265/97-19 on 971006-10.No Violations Noted.Major Areas Inspected:Ep Program IR 05000254/19970181997-11-10010 November 1997 Insp Repts 50-254/97-18 & 50-265/97-18 on 970922-25. Violations Noted.Major Areas Inspected:Maintenance & Engineering IR 05000254/19970161997-11-0505 November 1997 Insp Repts 50-254/97-16 & 50-265/97-16 on 970825-29. Violations Noted.Major Areas Inspected:Fire Protection Program & Several App R Issues IR 05000254/19970201997-10-25025 October 1997 Insp Repts 50-254/97-20 & 50-265/97-20 on 970929-1002.No Violations Noted.Major Areas Inspected:Quality of Security Related Audits,Reviewed Effectiveness of Mgt Controls & Verified Performance of Protected Area Control Activities IR 05000254/19970151997-09-0303 September 1997 Insp Repts 50-254/97-15 & 50-265/97-15 on 970811-14.No Violations Noted.Major Areas Inspected:Station Chemistry & REMP IR 05000254/19970121997-07-31031 July 1997 Insp Repts 50-254/97-12 & 50-265/97-12 on 970707-16.No Violations Noted.Major Areas Inspected:Review of Plant Support Activities Re Physical Protection of Facility & Corrective Actions to Security Issues IR 05000254/19970081997-07-11011 July 1997 Insp Repts 50-254/97-08 & 50-265/97-08 on 970506-0616. Violations Noted.Major Areas Inspected:Operations,Maint & Surveillance,Engineering & Plant Support 1999-09-15
[Table view] Category:UTILITY
MONTHYEARIR 05000254/19900141990-10-0404 October 1990 Insp Repts 50-254/90-14 & 50-265/90-14 on 900805-0915. Violations Noted.Major Areas Inspected:Ler Review,Regional Request,Followup on TMI Action Items,Operational Safety Verification,Esf Sys & Monthly Maint Observations IR 05000254/19900121990-08-22022 August 1990 Safety Insp Repts 50-254/90-12 & 50-265/90-12 on 900617- 0804.No Violations Noted.Two Unresolved Items Noted.Major Areas Inspected:Licensee Action on Previously Identified Items,Ler Review,Regional Requests & Testing of Mods IR 05000254/19900101990-08-14014 August 1990 Insp Repts 50-254/90-10 & 50-265/90-10 on 900605-0802. Violations Noted.Major Areas Inspected:Allegation That 1/2 Emergency Diesel Generator Cooling Pump Could Not Fulfill Cooling of Diesel & ECCS Room Coolers IR 05000254/19900111990-07-13013 July 1990 Insp Repts 50-254/90-11 & 50-265/90-11 on 900611-14.No Violations or Deviations Noted.Major Areas Inspected: Licensee Radwaste Mgt Program,Including Solid,Liquid & Gaseous Wastes & Audits & Assessments IR 05000254/19900081990-07-11011 July 1990 Insp Repts 50-254/90-08 & 50-265/90-08 on 900429-0616.No Violations Noted.Major Areas Inspected:Licensee Action on Previously Identified Items,Ler Review,Operational Safety Verification & Monthly Maint Observation IR 05000254/19890241990-06-15015 June 1990 Insp Repts 50-254/89-24 & 50-265/89-24 on 891030-900518. Violations Noted.Major Areas Inspected:Local Leak Rate Test Program,Containment Integrated Leak Rate Test Procedure & Review of Licensee Actions on Previous Insp Findings IR 05000254/19900061990-05-15015 May 1990 Insp Repts 50-254/90-06 & 50-265/90-06 on 900318-0428. Violations Noted.Major Areas Inspected:Plant Operations,Esf Sys,Radiological Controls,Maint & Surveillance,Emergency Preparedness,Security & Engineering/Technical Support IR 05000237/19900141990-04-20020 April 1990 Insp Repts 50-456/90-11,50-457/90-14,50-454/90-13, 50-455/90-12,50-237/90-14,50-249/90-13,50-373/90-07, 50-374/90-08,50-254/90-07,50-265/90-07,50-295/90-10 & 50-304/90-11 on 900220-0404.No Violations Noted IR 05000254/19900051990-04-10010 April 1990 Insp Repts 50-254/90-05 & 50-265/90-04 on 900326-30.No Violations Noted.Weaknesses Re Testing of New Whole Body Counter Noted.Major Areas Inspected:Operational Radiation Protection Program,Including External Exposure Controls IR 05000254/19900021990-04-0404 April 1990 Safety Insp Repts 50-254/90-02 & 50-265/90-02 on 900128- 0317.Violation Noted.Major Areas Inspected:Licensee Actions on Previous Items,Plant Operations,Radiological Controls, Maint/Surveillance,Emergency Preparedness & Security IR 05000265/19900051990-03-30030 March 1990 Safety Insp Rept 50-265/90-05 on 900220-0322.No Violations or Deviations Noted.Major Areas Inspected:Inservice Insp Activities,Including Review of Program,Procedures,Work Activities & Insp Data IR 05000254/19900041990-03-23023 March 1990 Insp Repts 50-254/90-04 & 50-265/90-03 on 900312-16.No Violation Noted.Major Areas Inspected:Mgt Support,Security Program Plans & Audits,Protected & Vital Area Physical Barriers & Detection & Assessment Aids IR 05000254/19890281990-02-13013 February 1990 Safety Insp Repts 50-254/89-28 & 50-265/89-28 on 891217-900127.No Violations Noted.Major Areas Inspected: Licensee Actions on Previous Items,Plant Operations, Radiological Controls,Maint Surveillance & Security IR 05000254/19890251990-01-0909 January 1990 Insp Repts 50-254/89-25 & 50-265/89-25 on 891030-1214. Violations Noted.Major Areas Inspected:Mods & Design Changes Implemented During Unit 1 Outage & Recent Request from Temporary Waiver of Compliance from Tech Specs IR 05000254/19890261990-01-0505 January 1990 Safety Insp Repts 50-254/89-26 & 50-265/89-26 on 891105- 1216.Violations Noted.Major Areas Inspected:Plant Operations,Radiological Controls,Allegations,Emergency Preparedness,Security & Engineering/Technical Support IR 05000254/19890271990-01-0505 January 1990 Insp Rept 50-254/89-27 on 891215.No Violations Noted.Major Areas Inspected:Review of Adequacy of Licensee Analysis of Reactor Feedwater Transient on Min Critical Power Ratio Safety Limit & Determination of Cause of Turbine Trip IR 05000254/19890221989-11-30030 November 1989 Insp Repts 50-254/89-22 & 50-265/89-22 on 890924-1104. Violations Noted.Major Areas Inspected:Plant Operations, Radiological Controls,Maint/Surveillance,Emergency Preparedness,Security & Engineering/Technical Support IR 05000254/19890171989-11-28028 November 1989 Insp Repts 50-254/89-17 & 50-265/89-17 on 890918-22,1002-06 & 18.Violations Noted.Major Areas Inspected:Maint,Support of Maint & Related Mgt Activities IR 05000254/19890231989-11-22022 November 1989 Insp Repts 50-254/89-23 & 50-265/89-23 on 891016-20 & 1115. Violations Noted.Major Areas Inspected:Implementation of Licensee Fire Protection Program,Including Followup of Licensee Actions on Previous Insp Findings IR 05000254/19890211989-11-16016 November 1989 Safety Insp Repts 50-254/89-21 & 50-265/89-21 on 890926, 1002-04 & 12-13 & 1102.No Violations or Deviations Noted. Major Areas Inspected:Inservice Insp Activities,Including Review of Programs,Procedures & Work Activities IR 05000254/19890201989-10-0606 October 1989 Insp Repts 50-254/89-20 & 50-265/89-20 on 890820-0923. Violations Noted.Major Areas Inspected:Licensee Actions on Previous Items,Plant Operations,Radiological Controls, Emergency Preparedness,Security & Maint/Surveillance IR 05000254/19890161989-08-28028 August 1989 Insp Repts 50-254/89-16 & 50-265/89-16 on 890625-0819. Violations Noted.Major Areas Inspected:Plant Operations, Radiological Controls,Maint/Surveillance,Safety Assessment/ Quality Verification,Emergency Preparedness & Security IR 05000254/19890181989-08-24024 August 1989 Physical Security Insp Repts 50-254/89-18 & 50-265/89-18 on 890814-18.No Violations Noted.Major Areas Inspected:Mgt Support,Security Program Plans,Audits,Protected & Vital Area Physical Barriers & Detection & Assessment Aids IR 05000254/19890121989-07-17017 July 1989 Insp Repts 50-254/89-12 & 50-265/89-12 on 890514-0624.One licensee-identified Violation & Two Unresolved Items Noted. Major Areas Inspected:Licensee Actions on Previous Items, Plant Operations,Emergency Preparedness & Security ML20246C3471989-06-29029 June 1989 Safety Insp Repts 50-254/89-13 & 50-265/89-13 on 890522-0608.No Violations,Deviations or Open Items Noted. Major Areas Inspected:Maint & Inservice Testing of Pumps & Valves,Including Actions in Response to NRC Bulletin 85-003 IR 05000254/19890151989-06-28028 June 1989 Insp Repts 50-254/89-15 & 50-265/89-15 on 890619-21.No Violations Noted.Major Areas Inspected:Radwaste Mgt Program, Including Solid,Liquid & Gaseous Radwastes,Audits & Assessments & Unplanned Liquid Radwaste Release IR 05000254/19890141989-06-27027 June 1989 Insp Repts 50-254/89-14 & 50-265/89-14 on 890605-09.No Violations or Deviations Noted.Major Areas Inspected: Implementation of NRC Bulletin 88-010 Requirements Re molded-case Circuit Breakers IR 05000254/19890101989-05-22022 May 1989 Insp Repts 50-254/89-10 & 50-265/89-10 on 890402-0513.No Violations Noted.Major Areas Inspected:Plant Operations, Radiological Controls,Maint/Surveillance,Emergency Preparedness,Security & Engineering/Technical Support IR 05000254/19890041989-04-13013 April 1989 Insp Repts 50-254/89-04 & 50-265/89-04 on 890205-0401.No Violations Noted.Major Areas Inspected:Plant Operations, Radiological Controls,Maint/Surveillance,Emergency Preparedness & Security IR 05000254/19890061989-03-0707 March 1989 Insp Repts 50-254/89-06 & 50-265/89-06 on 890214-17.No Violations Noted.One Potential Contamination Control Weakness Noted.Major Areas Inspected:Radiation Protection Program,Including Organization & Mgt Controls & ALARA IR 05000254/19890051989-02-27027 February 1989 Insp Repts 50-254/89-05 & 50-265/89-05 on 890206-10.No Violations Noted.Major Areas Inspected:Chemistry Program, Including Procedures,Organization & Training & Radiological Environ Monitoring Program & Qc/Qa Program in Lab IR 05000254/19880201988-10-13013 October 1988 Insp Repts 50-254/88-20 & 50-265/88-20 on 880807-0930.No Violations or Deviations Noted.Major Areas Inspected: Operations,Maint,Surveillance,Ler Review,Routine Repts, Temporary Instructions,Radiation Control & Info Notices IR 05000254/19880211988-10-0505 October 1988 Insp Repts 50-254/88-21 & 50-265/88-21 on 880222-0901. Violations Noted.Major Areas Inspected:Compliance W/App R to 10CFR50 & Review of Fire Protection Program Requirements IR 05000254/19880191988-09-22022 September 1988 Insp Repts 50-254/88-19 & 50-265/88-19 on 880830-0902.No Violations Noted.Weakness & Four Open Items Identified.Major Areas Inspected:Annual Exercise IR 05000254/19880251988-09-20020 September 1988 Insp Repts 50-254/88-25 & 50-265/88-26 on 880908-14.No Violations Noted.Major Areas Inspected:Licensee Written Practice for Nondestructive Exam Pertaining to 25% Rule Described in SNT-TC-1A ML20154L9461988-09-14014 September 1988 Insp Rept 50-265/88-24 on 880826.No Violations Noted. Major Areas Inspected:Weakness Identified in Verification of Component Operability as Documented in Insp Repts 50-254/88-15 & 50-265/88-15 ML20154L7701988-09-14014 September 1988 Corrected Pages 13 & 14 to Insp Repts 50-254/88-15 & 50-265/88-15 IR 05000254/19882001988-09-0707 September 1988 Emergency Operating Procedures Insp Rept 50-254/88-200 on 880613-30.Inadequacies & Deficiencies Noted.Major Areas Inspected:Determination If Procedures Technically Correct & Whether Procedures Could Be Carried Out & Performed IR 05000254/19880181988-07-29029 July 1988 Partially Withheld Physical Security Insp Repts 50-254/88-18 & 50-265/88-18 on 880718-21 (Ref 10CFR73.21).Noncompliances Noted.Major Areas Inspected:Security Plan & Implementing Procedures & Mgt Effectiveness IR 05000254/19880171988-07-14014 July 1988 Insp Repts 50-254/88-17 & 50-265/88-17 on 880706-07.No Violations Noted.Major Areas Inspected:Emergency Preparedness Program Areas,Including Actions on Previously Identified Items & Initiatives to Improve Program IR 05000254/19880161988-07-0101 July 1988 Insp Repts 50-254/88-16 & 50-265/88-16 on 880607-15. Violations Noted.Major Areas Inspected:Containment Integrated Leak Rate Test Procedure,Performance & Results, Local Leak Rate Test Results & LER Followup IR 05000254/19880121988-06-28028 June 1988 Insp Repts 50-254/88-12 & 50-265/88-06 on 880310-0411-12,18, 21,26-29 & 05-10,17-18 & 0601 & 20.No Violations Noted.Major Areas Inspected:Inservice Insp Activities,Including Review of Programs 73051,Procedures 73052 & Observation of Work IR 05000254/19880111988-06-21021 June 1988 Insp Repts 50-254/88-11 & 50-265/88-12 on 880422-0601. Violations Noted.Major Areas Inspected:Maint Activities & Followup on Previous Identified Insp Items Using Selected Portions of Listed Insp Modules IR 05000254/19880131988-06-15015 June 1988 Insp Repts 50-254/88-13 & 50-265/88-13 on 880510-20. Violation Noted.Major Areas Inspected:Radwaste Mgt & Radiation Protection Programs During Refueling & Maint Outage Including Organization & Mgt Controls IR 05000254/19880091988-06-0707 June 1988 Insp Repts 50-254/88-09 & 50-265/88-10 on 880403-0604.No Violations Noted.Major Areas Inspected:Operations,Maint, Surveillance,Ler Review,Routine Repts,Temporary Instructions & Administrative Controls Affecting Quality IR 05000254/19880101988-06-0606 June 1988 Insp Repts 50-254/88-10 & 50-265/88-11 on 880418-29.No Violations Noted.Major Areas inspected:safety-related Piping Weldments,Components & Supports Selected from Plant Mod Packages & Inservice Insp Plan IR 05000254/19880071988-05-0404 May 1988 Errata to Insp Repts 50-254/88-07 & 50-265/88-08 ML20151Z6211988-04-28028 April 1988 Insp Repts 50-254/88-07 & 50-265/88-08 on 880328-0407.No Violations Noted.Major Areas Inspected:Hpci/Rcic History & Mgt Activities,Root Cause Determination & Corrective Action & Maint Activities Re HPCI & RCIC IR 05000254/19880881988-04-27027 April 1988 Insp Repts 50-254/88-88 & 50-265/88-09 on 880404-08.No Violations Noted.Major Areas Inspected:Qa & Confirmatory Measurements for in-plant Radiochemical Analyses & Verification of TLD Collocation IR 05000254/19880041988-04-12012 April 1988 Insp Repts 50-254/88-04 & 50-265/88-04 on 880207-0402. Violations Noted.Major Areas Inspected:Operations,Maint, Surveillance,Ler Review,Routine Repts,Temporary Instructions & Administrative Controls Affecting Quality 1990-08-22
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARIR 05000254/19990171999-09-15015 September 1999 Insp Repts 50-254/99-17 & 50-265/99-17 on 990823-27.No Violations Noted.Major Areas Inspected:Pilot Baseline Insp for Annual Review of Changes to Safety Analysis Rept & Biennial Review Permanent Plant Mod IR 05000254/19990151999-08-25025 August 1999 Insp Repts 50-254/99-15 & 50-265/99-15 on 990816-20.No Violations Noted.Major Areas Inspected:Maint Rule Implementation IR 05000254/19990101999-08-20020 August 1999 Insp Repts 50-254/99-10,50-265/99-10,50-454/99-09, 50-455/99-09,50-456/99-10 & 50-457/99-10 on 990628-0721. Major Areas Inspected:Licensee C/A Approach & Implementation of Configuration Control Processes at Each Site IR 05000254/19990161999-08-19019 August 1999 Insp Repts 50-254/99-16 & 50-265/99-16 on 990719-22. Violations Noted.Major Areas Inspected:Physical Protection Cornerstone,Including Review of Access Authoization Program & Changes to Security Plan IR 05000254/19990121999-08-13013 August 1999 Insp Repts 50-254/99-12 & 50-265/99-12 on 990628-0716. Violations Noted.Major Areas Inspected:Corrective Action Process Which Included Methods Used for Identification, Cause Investigation & Correction of Quality Related Items IR 05000254/19990111999-08-13013 August 1999 Insp Repts 50-254/99-11 & 50-265/99-11 on 990601-0720.NCVs Noted.Major Areas Inspected:Performance in Initiating Events,Mitigating Sys,Barrier Integrity Cornerstones & Performance Indicator Verification IR 05000254/19990141999-07-30030 July 1999 Insp Repts 50-254/99-14 & 50-265/99-14 on 990713-15.One Violation Noted & Treated as Ncv.Major Areas Inspected: Heat Sink Performance,Which Covers Inspectable Area Under Initiating Events & Mitigation Sys IR 05000254/19990131999-07-29029 July 1999 Insp Repts 50-254/99-13 & 50-265/99-13 on 990628-0702.No Violations Noted.Major Areas Inspected:Public Radiation Safety & Review of Gaseous & Liquid Radiological Effluents & of Radiological Environmental Monitoring Program IR 05000254/19990091999-06-23023 June 1999 Insp Repts 50-254/99-09 & 50-265/99-09 on 990421-0531.One Violation of NRC Requirements Occurred & Being Treated as non-cited Violation.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000254/19990061999-05-14014 May 1999 Insp Repts 50-254/99-06 & 50-265/99-06 on 990307-0420.Three Violations Noted & Being Treated as non-cited Violations. Major Areas Insptected:Aspects of Licensee Operations,Maint, Engineering & Plant Support IR 05000254/19990081999-05-11011 May 1999 Insp Repts 50-254/99-08 & 50-265/99-08 on 990419-23.No Violations Noted.Major Areas Inspected:Adequacy of Licensee Programs,Procedures,Training & Supporting Documentation IR 05000254/19990031999-04-0909 April 1999 Insp Repts 50-254/99-03 & 50-265/99-03 on 990308-12.No Violations Noted.Major Areas Inspected:Maint & Engineering IR 05000254/19990011999-04-0101 April 1999 Insp Repts 50-254/99-01 & 50-265/99-01 on 990121-0306. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000254/19990071999-03-31031 March 1999 Radiation Protection Insp Repts 50-254/99-07 & 50-265/99-07 on 990309-12.No Violations Noted.Major Areas Inspected:Solid Radwaste Processing & Control Program & Radioactive Matls Shipping Program IR 05000254/19980211999-03-0505 March 1999 Insp Repts 50-254/98-21 & 50-265/98-21 on 981112-1218. Violation Noted:Major Areas Inspected:Isi Activities at Plant During Refueling Outage 15 ML20207G1771999-03-0505 March 1999 Notice of Violation from Insp on 99112-1218.Violation Noted:Licensee Had Not Included in Revised ISI Program,Basis for Determination That Code Required Exam Was Impractical For,Unit 2 Reactor Pressure Vessel Nozzle Weld Nsb IR 05000254/19990041999-02-26026 February 1999 Insp Repts 50-254/99-04 & 50-265/99-04 on 990201-05.No Violations Noted.Major Areas Inspected:Emergency Prepardeness Program as Aspect of Plant Support IR 05000254/19990021999-02-25025 February 1999 Insp Repts 50-254/99-02 & 50-265/99-02 on 990125-29.No Violations Noted.Major Areas Inspected:Radiation Protection & Chemistry Program Included Water Chemistry Control, Instrument Quality Control & internal-lab Comparison IR 05000254/19980241999-01-14014 January 1999 Partially Withheld Security Insp Repts 50-254/98-24 & 50-265/98-24.Violations Noted.Major Areas Inspected:Plant Support Activities Re Physical Protection of Quad Cities Facility.Details Withheld (Ref 10CFR2.790) IR 05000254/19980221998-12-28028 December 1998 Insp Repts 50-254/98-22 & 50-265/98-22 on 981130-1204.No Violations Noted.Major Areas Inspected:Radiation Protection Staff Preparation for Q1R15 Refueling Outage,Including Review of ALARA Planning & Work Plan Integration IR 05000254/19980201998-12-28028 December 1998 Insp Repts 50-254/98-20 & 50-265/98-20 on 981014-1201.No Violations Noted.Major Areas Inspected:Operations,Maint & Plant Support IR 05000254/19980191998-12-18018 December 1998 Insp Repts 50-254/98-19 & 50-265/98-19 on 981019-1106. Violations Noted.Major Areas Inspected:Effectiveness of Engineering & Technical Support Provided to Plant in Performance of Routine & Reactive Site Activities ML20198G2901998-12-18018 December 1998 Notice of Violations from Insp on 981019-1106.Violations Noted:As of 980327,performance of Listed Test Procedures Did Not Demonstrate Equipment Could Perform Satisfactorily Under Design Conditions IR 05000254/19980171998-11-0505 November 1998 Insp Repts 50-254/98-17 & 50-265/98-17 on 980902-1014.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000254/19980181998-10-15015 October 1998 Partially Withheld Insp Repts 50-254/98-18 & 50-265/98-18 on 980914-18 (Ref 10CFR73.71).No Violations Identified.Major Areas Inspected:Review of Plant Support Activities,Security Activities Re Onsite Personnel Access & Communications IR 05000254/19980131998-09-22022 September 1998 Insp Repts 50-254/98-13 & 50-265/98-13 on 980716-0901.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000254/19980141998-09-17017 September 1998 Insp Repts 50-254/98-14 & 50-265/98-14 on 980825-28.No Violations Noted.Major Areas Inspected:Evaluation of Licensee Performance During Plant Biennial Exercise of Emergency Plan ML20154G4301998-09-11011 September 1998 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $88,000.Violation Noted:As of 970926,licensee Failed to Provide Alternate Shutdown Capability for Some Fire Areas of Facility Containing Safe Shutdown Equipment ML20195D1951998-09-0808 September 1998 EN-98-057B:on 980911,notice of Proposed Imposition of Civil Penalty in Amount of $88,000 Issued to Licensee.Action Based on One Severity Level II Problem Involving Very Significant Inadequacies in Comm Ed Capability to Shut Down IR 05000254/19980161998-09-0404 September 1998 Insp Repts 50-254/98-16 & 50-265/98-16 on 980810-14.No Violations Noted.Major Areas Inspected:Radiation Protection Program Included External & Internal Exposure Control,Whole Body Counting & Contamination & Survey Monitoring Program ML20195D2341998-08-11011 August 1998 EN-98-057:on 980814,notice of Proposed Imposition of Civil Penalty in Amount of $143,000 Issued to Licensee.Action Based on One Severity Level II Problem & One Severity Level III Violation ML20237D6671998-08-11011 August 1998 Notice of Violation from Insp on 980529-0716.Violation Noted:On 980622,while Performing Quad Cities Operating Surveillance Procedure 6600-01,rev 24,operator Failed to Position Throttle Air Box Drain Valve One Turn IR 05000254/19980151998-07-31031 July 1998 Insp Repts 50-254/98-15 & 50-265/98-15 on 980721-24.No Violations Noted.Major Areas Inspected:Aspects of Licensee Corrective Actions & Engineering Involvement in Corrective Actions Process IR 05000254/19980111998-07-0202 July 1998 Insp Repts 50-254/98-11 & 50-265/98-11 on 980504-22. Violations Noted.Major Areas Inspected:Quad Cities Safe Shutdown Analysis & Supporting Procedures ML20236M0831998-07-0202 July 1998 Notice of Violation from Insp on 980401-0529.Violation Noted:On 980501,Interim Procedure 98-0035 Was Not Implemented When Change Was Made to Personnel Out-of Svc Number 98-512 Which Was Not Reviewed & Approved ML20248L7951998-06-0505 June 1998 Notice of Violation from Investigation on 970530.Violations Noted:Licensee Provided to Commission on 960825,operability Determination Checklist.Info Inaccurate Because Supporting Calculations Showed FICs to Be Excess of 1.0 ML20237E7051998-06-0505 June 1998 EN-98-043:informs Commission That Staff Intends to Exercise Enforcement Discretion Per Section VI.B.6 of Enforcement Policy & Not Issue NOV to Util for Failure to Provide Complete & Accurate Info to NRC ML20247P4551998-05-15015 May 1998 Notice of Violation from Insp on 971014-980415.Violation Noted:On 971215,inspector Identified That Licensee Failed to Provide Training of Personnel Performing Activities Affecting Quality IR 05000254/19980081998-05-11011 May 1998 Insp Repts 50-254/98-08 & 50-265/98-08 on 980407-09 & 14-17. No Violations Noted.Major Areas Inspected:Maint,Quality Assurance & Engineering IR 05000254/19980101998-05-0606 May 1998 Insp Repts 50-254/98-10 & 50-265/98-10 on 980413-17.No Violations Noted.Major Areas Inspected:Liquid & Gaseous Effluent Programs,Annual Effluent Rept,Continuous Air & Area Radiation Monitors IR 05000254/19982011998-05-0606 May 1998 Insp Repts 50-254/98-201 & 50-265/98-201 on 980216-0327.No Violations Noted.Major Areas Inspected:Evaluation of Capability of Selected Sys to Perform Safety Functions Required by Design Bases ML20217G3401998-04-23023 April 1998 Insp Repts 50-254/98-04 & 50-265/98-04 on 980211-0331. Violations Noted.Major Areas Inspected:Operations, Engineering,Maint & Plant Support ML20217G2341998-04-23023 April 1998 Notice of Violation from Insp on 980216-0326.Violation Noted:Between 971006 & 10,work Package 970104149-03 Replaced 2A Recirculation Loop Sample Pci Valve AO-2-0220-44,activity Affecting Quality,Prepared & Installed Prior to 971014 ML20217G3101998-04-23023 April 1998 Notice of Violations from Insp on 980211-0331.Violations Noted:On 980314,non-licensed Operators Performing Plant Operating Procedure 6600-7,rev 6,attachment H,Failed to Charge Breaker Closing Spring for Unit 2 IR 05000254/19980051998-04-23023 April 1998 Insp Repts 50-254/98-05 & 50-265/98-05 on 980216-0326. Violations Noted.Major Areas Inspected:Engineering,Including Allowances for Development of Emergency & Immediate Mods IR 05000254/19980071998-04-22022 April 1998 Insp Repts 50-254/98-07 & 50-265/98-07 on 980330-0403.No Violations Noted.Major Areas Inspected:Plant Support Activities Re Physical Protection of Plant,Adequacy of Security Procedures & Event Logs IR 05000254/19983031998-04-13013 April 1998 Exam Repts 50-254/98-303OL & 50-265/98-303OL on 980316-20. Exam Results:All Three Applicants Passed All Portions of Respective Exams ML20217D9661998-03-0909 March 1998 EN-98-010:informs That NOV & Proposed Imposition of Civil Penalty in Amount of $330,000 Will Be Issued on or About 980312 to Comm Ed.Action Based on Two Severity Level III Problems Consisting of Violations ML20216C2531998-03-0606 March 1998 Notice of Violation from Insp on 971224-980210.Violation Noted:From 971216-20,both Standby Gas Treatment Subsystems Inoperable & Unit 1 Remained in Mode 1 & Not Placed in Hot Shutdown Condition within 12 H ML20216C2601998-03-0606 March 1998 Insp Repts 50-254/97-28 & 50-265/97-28 on 971224-980210. Violations Noted.Major Areas Inspected:Operations,Maint & Engineering 1999-09-15
[Table view] |
Text
L
,
-.,
-
+..
I
-
.
U.S. NUCLEAR REGULATORY COMMIS$10h REGION 111 Reports No. 50 254/90008(DM); LO-20E/90008(DRP)
Doc 6et Hos. 50 254; 50-265 Licenses No. DPR-29; DPR 30 Lisensee:
Comunweelth Edison Con.pany Post Office Box 767 Chicago, IL 60690 i
facility Nane: Quad Cities Nuclear Power Station Units 1 and 2 Inspection At: Quad Cities Site, Cordova, 1111nois
'"
Inspection Conducted: April 29 through June 16, 1990 Inspectors:
T. E. Taylcr J. M. Shine R. Bocanegra R. M. Lerch W. J. Kropp
'
Approved By Irfds 90L 11 190
"'""
Reactor Projects' $ection 1B Date I,spittjonSummer.y P
t 30-26 5 / 90DDh Dh>W " '" " "" g"'"'" ',"" " '(" p" '" "" """ /"90008 ( DR P);
'
inspection fron, April 29 throu h June 16 1990 Re orts No. 50-254 Areal'Ei~pi~c}ted:
" ' " "
!
Routine, unannounced safety inspection by the resident and-regionarliiifectors of licensee action on previcusly identified items; licensee event report review; cperational safety verification; nionthly maintenance observation; monthly surveillance observation; startup from.
refueling' activities; report review and. events.
Results:
During the' period, licensee managenent nainto1Md increased efforts To promote and achieve " error-free" perforn.ance.
Housekeeping efforts have i
received greoter managenient attention during the 'pericd, evidenced by'new i
initiatives in the areas of groundwater intrusion control and ECCS equipment
roone in.provements. Resolution of containment isolation valve testing and naintenance issues continues to be a weakness.
Technical staff experience and staffing levels-also continue to be a weakness, but management attention in this aree has_ been significant and staffing levels are beginning to increase.
Of the eight areas inspected, no violations were identified.
The resident inspectors continued to unitor pressure oscillations in the 28 reactor recirc pump outboard seal. Events followed by the residents included loss of control rod position indication and HDCI declared inoperable due to malfunctioning flow controller electronics.
9007170138 900711
'
PDR ADOCK 05000254
!
Q PDC i
i
!
I I-
<
.
.
Y
'
.
DETAILS
>
1.
Persons Contacted CommonwealthEdiscnCompanyjCECo)
N. J. Kalivianakis, Vice President, BWR Operations
- R. L. Bax, Station Manager R. A. Robey, Technical Superintendent
- G. Spedi, Production Superintendent R. Stols, Nuclear Licensing Administrator
- J. Swales, Assistant Superintendent, Operations J. Fish, Master Mechanic J. Sirovy, Services Director D. Craddick, Assistant Superintendent, Maintenance B. Tubbs, Operating Engineer, Unit 1 J. Kopact, Operating Engineer, Unit 1 B. Strub, Operating Engineer, Unit 2 M. Kooi, Operating Engineer, Unit 2 J. Wethington, Quality Assurance Supervisor D. Gibson, Regulatory Assurance Supervisor J. Dierbeck, Technical Staff Supervisor C. Smith, Quality Control Supervisor K. Leech, Security Administrator B. McGaffigan, Assistant Superintendent, Work Plat.ning D. Bucknell, Assistant Technical Staff Supervisor
- T. Barber, Regulatory Assurance T. Lihou, Work Planning
- R. Hopkins, Engineer, Nuclear Quality Programs.
- Denotes those attending the exit interview conducted on June 22, 1990, M
and at other times throughout the inspection period.
'
The inspectors also talked with and interviewed several other licensee employees, including members of the technical and engineering staffs, reactor and auxiliary operators, shif t engineers and foremen, and electrical, mechanical and instrument maintenance personnel, and contract security personnel.
2.
Licensee Action on Previously_ identified Items (92701 92702)
u a.
Viola t,i_ons (Closed) 50-254/90002-01:
This violation was issued for failing TU post a chiitiiiLBU's'TTFe wtch when combustibles were pretent in a fire zone. The licensee has revised two procedures to require stttion Fire Marshall approval prior to introducing transient comnustible material into the plant, and to require timely resolution of any unsatisfactory condition found in the plant. The corrective actions appear to be adequate to close this item.
I
!
L
f.
,
I
.
e v.
b.
_1. E. Bulletin (Closed)89-02:
Stress Corrosion Cracking in Anchor Darling Model
.
S350W Swing D eck Valves or Similar Yelves.
By letter dated January 17, 1990, the licensee responded that by reviewing plant docunentation, there are no swing check valves of this design installed in safety-related applications. The information search-method was discussed with the plant staff and there were no valves of this design installed in safety-related or balance of plant
,
'
applications. This item is closed.
No violations or deviations were identified.
3.
LicenseeEventRepott(LER) Review (92700)
Through direct observations, discussions with licensee personnel, and'
review of records, the following event reports were reviewed to determine that reportability requirements were fulfilled, that immediate corrective
' action was accomplished, and that corrective action to prevent recurrence had been or would be accomplished in accordance with Technical Specifications (TS):
a.
(Closed) 265/90006-LL:
Unit Two'RCIC Inoperable Due to New Flow controllir'TniliUlTHy Found During Initial Installation Testing.
The controller in question was installed during the recent refueling outage. The Instrument Mechanics (IM) who installed and programmed the controller, in an attemat to enhance the performance of the controller, adjusted down tle proportional band setting of the controller.
The device was bench tested with the-new setting prior to installation, and was also tested while in place during the normal RCIC ope..oility surveillance, both tests of which the controller performed adequately.
However, during the RCIC injection testing, flow oscillations occurred resulting in RCIC being declared
'noperable, and the NRC was notified. The IM reprogrentned the
~
controllerwiththeoriginaldata(higherproportionalband)and the system was retested, performed adequately, and was returned to service. The IM postulated that the controller, during the injection test, was reacting too quickly to flow oscillations possibly caused by the discharge check valve, leading to erratic operation.
The licensee plans to perform further testing to establish a proper proportional band setting that will enhance controller performance yet will not overcon:pensate for minor inherent flow perturbations.
This item is closed.
In addition to the foregoing, the inspector reviewed the licensee's DeviationReports(DVRs)generatedduringtheinspectionperiod.
This was done in an effort to monitor the conditions related to plant or personnel performance, potential trends, etc. DVRs were also reviewed for proper initiation and disposition as required by the applicable procedures and the QA manual.
No violations or deviations were identified.
]a
.
_ - - _
_ _ _ _ _
_ - _ _ - - - _ _ _ - _ _ _ _ _ _ _ _ _ _ _ - - _ - _ - _ - _ _ - _ _.
__
-
,
.,e
,
k f:*,
p-
>
'
.
.
4.
Operational Safety Verification (71707)
'[
i Overview of Activities
'i
[
During this inspection period, Unit 2 came out of a refueling outage on
fuy 7, 1990. The unit operated at or near full power for the remainder L
,
of the period.
Soon after coming out of the outage, the 2B Reactor
- l
[
Recirc pump outboard seal began experiencing pressure oscillations. At f
full: power the seal pressure stabilized and has oscillated intermittently
,
!
through-the remainder of the report period. The resident inspectors
continued to monitor the licensee's actions.
'
Unit 1 operated at full power or on EGC for the entire period with some
!
L power reductions required by the Chicago Load Dispatcher and scheduled
!
F surveillances.
'
F t
During the inspection period, the inspectors verified that the facility
'
was-being' operated in conformance with the licenses and regulatory
requirenents and that the licensee's managenent control system was
_
~
effectively carryino out its responsibilities for safe operation.
This
,'
r was done on a sampling basis through routine direct observation of t
'
activities and equipnent, tours of the facility, interviews and
'
discussions with licensee personnel, independent verification of safety
system status and limiting conditions for operation (LCOs), corrective action, < and review of facility records.
'
,,
On a sampling basis the inspecters daily verified proper control room
'
staffing and access, operator behavior, and coordination of plant i
activities with ongoing control rocm operations; verified operator t
adherence with the latest revisions of procedures for ongoing activities;
verified operation as required by Technical Specifications (TS);
including compliance with LCOs, with emphasis on engineered safety
.
features (ESF) electrical alignment and valve positions; monitored
,
instrunentation recorder traces and duplicate channels for abnormalities;
. verified status of various lit annunciators for operato understanding,-
J r
off-normal condition and corrective actions being take ; examined nuclear instrumentation and other protection channels for proper
operability; reviewed radiation monitors and stack monitors for abnormal
?
'
conditions; verified that onsite and offsite power was available as
.
.
required; observed the frequency of plant / control room visits by the station manager, superintendents, assistant operations superintendent,
!
- and other managers; and observed the Safety Parameter Display System
for operability..
'
On June 13, 1990, while a resident inspector observed control room
,
,
operations, with Unit 2 operating at about 95% power, operators entered i
p, a manual scram on the "A" channel of the reactor protection system.
This
'
was required because a flow bias scram signal had alarmed and was found
-!
to be too high.
The operators concluded that the high bias signal adversely affected one channel of average power range monitors and took
,
the action required by Technical Specifications, l
a
,
,
-
..
..
.
.
..
i
~~
Curing tours of accessible areas of the plant, the inspectors made note-of general plant / equipment conditions, including control of activities in
' ^.
progress (maintenance / surveillance), observation of shift turnovers, general safety items, etc. The specific areas observed were:
a.
EngineeredSafetyFeatures(ESF]_Sy,s, ten 3 Accessible portions of ESF systems and components were inspected to verify: valve position for proper flow path; proper alignnent of
,
f power supply breakers or fuses (if visible) for proper actuation on an initiating signal; proper removal of power from components if g
'
required by TS or FSAR; and the opt.rability of support systems essential to system actuation or performance through observation of instrumentation and/or proper valve alignment. The inspectors also visually inspected components for leakage, proper lubrication,.
cooling water supply, etc.
b.
Radiation P_rotection Controls The inspectors verified that workers were following health physics procedures for dosimetry, protective clothing, frisking, posting, etc., and randomly examined radiation protection instrunentation for use, operability, and calibration.
- c.
Security The inspect 6rs, by sampling, verified that persons in the protectcd area (PA) displayed proper badges and had escorts if requirtd; vital areas were kept locked and alarmed, or guards posted if required; and personnel and packages entering the pA received proper search and/or monitoring, d.
-Housekeeppg and Plant Cleanliness The inspectors monitored the status of housekeeping and plant cleanliness for fL protection,-protection of safety-related equipment from intrusion of foreign natter and; general protection.
The inspectors also monitored ver+.eus records, such as tagouts,, jumpers, shiftly logs and surveillances, daily orders, maintenance items, various chemistry and radiological sampling and analysis, third party review results, overtime records, QA and/or QC audit results and postings required per 10 CFR 19.11.
No violations or deviations were identified.
5.
Monthly Maintenance Observation (62703)
Station mointenance activities affecting the safety-related systems and components listed below were observed / reviewed to ascertain that they were conducted 'in accordance with approved procedures, regulatory guides and industry codes or standards, and in conformance with Technical Specifications.
s
<
Y'
r_,
h-
,.
4r,
-
L,
I-The following items were considered.during this review:
the limiting l.
conditions for operation were met'.while components or systems were p
removed from and. restored to service; approvals were obtained prior
,
to initiating ~ the work; activities were accomplished using approved
-
p procedures and were inspected as applicable; functional testing end/or k,
calibrations were perforned prior to returning components or systems
,
l to service; quality control records were maintained; activities were bs
' accomplished by~ qualified personnel; parts and materials used were p
properly, certified; radiological controls were implenented; and fire prevention controls were' implemented. -Work requests were reviewed to F
->.
(:
determine the status of outstanding jobs and to assure that priority is
,,
~
assigned to safety-related equipn,ent maintenance which may affect system performance.
'
>
,
. The following maintenance activities were observed and reviewed:
f Unit 1/2 1/2 "A": Fire Diesel Modification Unit 1-Preventive Maintenance Program - 250V DC Cutler Hammer Motor Control
-
!.
Centers.
,
"B" RWCU Pump Overhaul.
<
Unit 2 250V DC Battery Corrosion Control Maintenance RBCCW Expansion Tank Hi-Level Alarm.-
i HPCI Flow controller - Vendor Reconmended Repair i
,
"A" Service Air Compressor Overhaul.
Essential Service Bus Uninterruptible Power Supply - Irve +.er-
. Troubleshooting and Repair-
.
The inspectors monitored the licensee's work:in pt' ogress and verified:
that it was being performed in accordance with proper procedures, and.
opproved work packages, that 10 CFR 50.59 and other applicable drawing
- updates were made and/or. planned, and that operator training was conducted in a reasonable period of time.
No violations or deviations were identified.
L
!
'
,
,m
g T
r
,
..,
-
<
.
Mon _t!Ly,SurveillanceObservation_(61726)
l 6..
The inspectors observed surveillance testing required by Technical Specifications during the inspection period and verified that testing
-
was performed in accordance with adequate procedures, that t(st instrumentation was calibrated, thet LCOs were net, that removal and restoration of the effected components were accomplished, that results conformed with Technical Specifications and procedure requirements and
were reviewed by personnel other then the individual directing the test, and that any deficiencies identified during the testing were properly reviewed and resolved by appropriate management perconnel.
_
During the current Unit 2 refueling outage (Spring 1990) the licensee
.
performed LLRT on seven volumes that had never been tested before. One of the volumes (RBCCW) failed which delayed the Unit 2 startup. It subsequttitly passed af ter repairs.
In addition to the above concern, Region III Division of Reactor Safety L
(DRS) raised a concern that several paths for containment leakage,
--
including RBCCW System, were also not tested during the last Unit I refueling outage (Fall 1989). Assuming that the Unit 1 RBCCW volume
-
-leaks at the same rate as the Unit 2 RBCCW volume, when added to the previous ILRT leakage, would increase the total leakage to an
=
unacceptable level.
On May 22, 1990, NRR granted the licerdee a waiver of compliance to allow operation of Unit I until October 1990 without performing Type C tests on the eight LLRT volumes of concern based on a
"
determination that the added risk of operating the plant under these conditions was insignificant.
DRS is following this issue.
The inspectors also witnessed portions of the following test activities:
Unit 1/2
-
'
c
_
QOS' 9910-S1, Security Emet gency Diesel Generator Surveillance Test.
Temporary Procedure 6218, Emergency Diesel Generator Cooling Water
'-
System Capacity Test.
Unit 1
.
'Q0S 2300-S2, HPCI Pump Operability.
QOS 2300-S3, HPC1 Valve Operability.
QOS 1300-S1, RCIC Pump Operability.
.
-QOS 1300-S3, RCIC Valve Operability.
005 6600-51, Emergency Diesel Generator Load Test, Fuel Transfer
-
Operability and Starting Air Operability, i
_
_
.. _ _ _
_ _ _.......... _
...
g}
c. "
q w.
}
"
..
i
,-
t
.
!
Unit ?
,
"D" RHRSW Pump Vibration Surve111ances, b
QOP 700-6, Traversing Incore Probe Procedure,
,
o j
Q05.1400-53, Core Spray Purnp Operability,
'
QOS 1400-S2, Core Spray Pump Operability.
t i
i
.QOS.1000-S2, Low Pressure Coolant Injection Pump Operability,
.
h
,
[
Q05-1000-S3, Low Pressure Coolant Injection Valve Operability.
.
'
No violations or deviations were identified.
'StgtupFromRefuelinglctiviti_es(71711)
7.
t The licensee began pulling rods on Unit 2 on May 7,1990, ending a l
refueling outage which had started on February 4.1990. Startup had been L
delayed since May'2,1990, due to maintenenre work being perfortned on an outboard isolation valve in the Reactor Building: Closed Cooling Water-(RBCCW) system which had failed a local leak rate test. Major work-and modifications.done during the outage included-refueling Unit.2, installing new "A" and "B" low pressure turbine rotors, removal of head o-spray piping, removal of the control rod drive (CRD) return line, and:
replacing Reactor Water Cleanup System piping due to-intergranular stress i
corrosion crackingL(IGSCC).
i The inspectors also. witnessed portions of the following outage and prior to startup test activities:
~
,QlP 700-2, LPRM Cable Connection' Verification.-
QIP 730-4, Nuclear Tube Tip. Connection Verification.
Q15 130-4, Hot Scram Time Testing.
-,
-QTS'1104-01, Shutdown Margin Demonstration.
-QTS 110-3, ECCS-Simulated Automatic Actuation and Diesel Generator
~ Auto-Start Surveillance.
,
' Pre-Startup Drywell Inspection.
--
LQTS 150-1, Containnent Integrated Leak Rate Test.
Approach to and Achievenent of Criticality.
No violations or deviations were were identified.
i l
..
4
!
g
.w
.
.
.
- 9 m gyp v
m
,,
,
' pk W%,
f*J f M. y,.
bd.
,
[M[s a 8.-
TraininLEEec_t_iveness_(41400.41701)
m
,
p
&
The~ effectiveness of. training programs for licensed and non-licensed M
f personnel was reviewed by the inspectors during the witnessing of'
. f'
the. licensee's performance of. routine surveillance, maintenance, and
'**
. operational activities and during the review of the licensee's response at to. events which occurred during the' inspection period.
personnel
-
y, appeared to be knowledgeable of the tasks being performed, and nothing f,,, w.
was observed which' indicated any ineffectiveness of training.
s.
L.-
-
'No violations or deviations were identified, f
'"
9.
Report Review n
During the inspection period, the inspector reviewed the licensee's i
v,f Monthly Performance Report for April and May 1990.
y l<
~ The inspector also reviewed the licensee's Monthly platt Status Reports for March and April 1990.
'
,
Lc No-violations or deviations were identified.
10.
Egnts(93702)
.a.
Loss of RpIS On_ June 1,1990, at approximately 4:00 p.m. with Unit 2 at 100%
power, a: blown fuse in the Control Rod position and Information System (RPIS) resulted in the loss of control rod position
.
- indication for control rods located in the lower half of the ful1~
-core display. ~0ther components rendered inoperative included the Rod Block Nonitor, Rod Worth Minimizer, and the OD-7 computer routine for control rod position verification.
The. licensee
,
identified the cause to be a blown fuse, reset the associated alarms, and the affected systems were returned to normal operation
'
in approximately 28 minutes. Power supply related failures on the RplS system have been a recurring. problem.
During the event the
- licensee monitored the reactor operation utilizing the Neutron
,
Monitoring system, diagnosed the failure, and consulted the TechnicalSpecifications(TS)fortheproperactionstatement. 'The TS did not: specifically address the event (simultaneous loss of multiple control rod position indications) so TS 3.0.A. " Limiting Conditions for 0peration (LCO) - General" ras properly entered at 4:00 p.m. and exited at 4:43 p.m., prior to being required to initiete a reactor shutdown.
The licensee was prepared to insert a
- manual' scram if the RPIS was not fully restored within I hour.
The licensee promptly notified the NRC and will submit 'an event report
'
per 10 CFR 50.73.
The inspectors will assess the licensee's corrective actions pursuant to the event report.
E
1 k
-
-
f
.w.
L,-.
j w-
.
'
f b'. - - High pressure Coolant IQegion System Found Inoperable l
t
.
'
On June 2,1990,- at approximately 5:23 p.m., the Unit 2 Nuclear
}'
. Station Operator (NS0) observed that the High pressure Coolant
!
Injection (HPCI) flow ~ntroller had switched from the " Automatic"
-to " Manual" mode, the " Fail" light on the controller was lit, and'
!
the setpoint was slowly drifting down (it had decreased to 3260 gpm
.j
'
from5600gpm).
The most recently docunented panel verification r
L indicated that the controller was in auton.atic as logged by the
!
SCRE at approximately 4:45 p.m..
The operator unable to return the
!-
controller-to " Automatic", but was able to operate the controller in
..'
the~" Manual" mode. The HPCI system was declared inoperable, the NRC
,
L was notified, and the IMs were called in,
,
L'
t The HPCI flow controller manufactured by Yokogawa (model SLPC-271E),
.j
"
'
was installed in Unit 2 during the recent refueling outage and'in-
<
Unit 1 in fall of 1989. No problems have been identified with the
,
,
controller for Unit L
!
g
_
!
The IMs found that the controller was indicating an "EpROM" error.
l The error indicated that the controller was unable to access the
!
basic program, indicating that possibly the RAM chip contacts'had l
failed. However, the IMs were unable to completely verify that the
!
error was due to the failed' RAM chip because the controller returned
-t to service during troubleshooting activities. The controller
returned to service by initiating and successfully running its i
diagnostic routine.
The controller was then returned to " Automatic" l
"
'
and-the HPCI operability surveillance was run.
The'IMs postulated
'
that the malfunction was possibly spurious, or might indicate a
-
prob.lem with the microprocessor.
The vendor has indicated that -
~;
,
'
two similar feilures have occurred.
The vendor recommended s
'
L
. replacement of the "EPROM" portion of the unit, and the licensee
.
,
1s.taking steps to achieve this. The inspectors will verify the j
corrective maintenance activities pursuant to the 50.73 report..
- 4 No' violations or deviations were identified, l
'
m'
' ll. : Exit ' Interview Q0703)
%"
}
The inspectors met with the licensee representatives denoted in J
.
Paragraph I during the inspection period and at the conclusion of the-q di inspection on June:22, 1990. The inspectors sumarized the sco)e and i
results of the inspection and discussed the likely content of tlis
!
p inspection report.
The-licensee acknowledged the inforn;ation and did not
' indicate that any-of the information disclosed during the inspection q
-
-
could be considered proprietary in nature.
-
4 r
i
t
,
"):
i
,