August 21, 2023 L-2023-115 10 CFR 50.55a U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555-00001 Re: Turkey Point Unit 3 Docket No. 50-250 lnservice Inspection Program Owner's Activity Report (OAR-1)

Attached find the Owner's Activity Report (Form OAR-1), for Turkey Point Unit 3 (PTN3 - 33), Fifth lnservice Inspection Interval, Third Period, and IWE Third Interval, Second Period. The Form OAR-1, Owner's Activity Report, implements Code Case N-532-5.

Should there be any questions concerning this report, please contact Kenneth Mack at (561) 904 - 3635.

Sincerely, Vt<c- ~

Dianne Strand General Manager, Regulatory Affairs Florida Power & Light Company

Attachment:

PTN3-33 Refueling Outage OAR-1 Owner's Activity Report cc: Regional Administrator, Region II, USNRC Senior Resident Inspector, USNRC, Turkey Point Plant Florida Power & Light Company 9760 S.W. 3441" Street Homestead , FL 33035

Attachment 1 Engineering Evaluation: PTN-ENG-SESJ-23-004 Rev. 0 EC-298869 Rev. 0 Page 1 of 6 FORM OAR-1 OWNER'S ACTIVITY REPORT Report Number: ISi PTN3-33 2023 Plant Turkey Point Nuclear Power Plant Unit 3 9760 SW 344th Street Homestead. Florida 33035 Commercial Service Date: December '14. 1972 Refueling Outage No.: PTN 3-33 Current Inspection Interval: ISi-Fifth IWE-Third Current Inspection Period: ISi-Third Period and !WE-Second Period Edition and Addenda of Section XI applicable to the inspection plans: ISi Fifth lnterval-2007 Edition through the 2008 Addend and IWE Third lnterval-2007 Edition through the 2008 Addenda.

Date and Revision of Inspection Plans: ISi Fifth Interval Effective-July 28. 2023 Rev.3 and IWE Third Interval Effective July 15. 20'18. Rev.0 Edition and Addenda of Section XI applicable to repairs and replacements, if different than the inspection plan: Same Code Cases Used: N-532-5. N-73*1. N-729-6 CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in this report are correct; (b) the examinations and tests meet the Inspection plan as required by the ASME Code,Section XI; and {c) the repair/replacement activities and evaluations.

supporting the completion of PTN3-33 conform to the requirements of Section XI.

Signed,£.- ~ - < ! : 5 = Site PrQQram Manager Date oe,/,s/ui'L"3 Owner or Own r's Designee, Title i '

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by the Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in this Owner's Activity Report, and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair/replacement activities and evaluation described in this report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

_.,,.4e:w..-"'~~:......;:: ===------Commissions NB 156481. N, R Inspector's Signature National Board Number and Endorsement Date 16Aug2023

Attachment 1 Engineering Evaluation: PTN-ENG-SESJ-23-004 Rev. 0 EC-298869 Rev. 0 Page 2 of 5 FORM OAR-1 OWNER'S ACTIVITY REPORT TABLE 1 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE Examination Category and Item Description Evaluation Description Item Number E-A Liner AR02456070 E1 .11 Description Identified Boric acid was observed on the Reactor Sump liner walls. The conditions observed, while rejectable, did not appear as fresh active boric acid and exhibited no apparent significant change from the previous observation.

Evaluation The quarter-inch thick plate had no signs of pitting or wastage, the liner has maintained complete integrity as per the original design. These areas are a source of borated water in the reactor pit area from the upper past cavity seal ring and floor when the cavity is flooded.

There are currently no indications /conditions that would appear to challenge the containment structural integrity of the structural integrity/leak tightness of the containment liner boundary during Modes 1-4 Conclusion WO 40801001-01 has been created to clean and coat deficient locations as required. This shall be implemented during PTN3-34 Refueling Outage.

Attachment 1 Engineering Evaluation: PTN-ENG-SESJ-23-004 Rev. 0 EC-298869 Rev. 0 Page 3 of 5 FORM OAR-1 OWNER'S ACTIVITY REPORT TABLE 1 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE Examination Category and Item Description Evaluation Description Item Number F-A CCW Head Tank AR02455047 F1.30 Description Identified The following recordable indications and discrepancies were observed while performing an ASME Section XI VT-3 on the CCW Head Tank 3T216. 1) Corrosion was served on the bottom support lower nuts, 2) Multiple gaps were observed between the support plate and embedded baseplate where caulking has degraded, and 3) discrepancy was identified on the as-built drawing. An approximately 3/8" gap was observed on the lower support (North end),

where a weld was required by drawing.

Evaluation The corrosion identified on the lower nuts appears to be surface corrosion. It will not affect the ability of the bolt to transfer tension or reduce the shear capacity of the bolt. The bolts are fully engaged with adequate thread engagement. The bolts described are in place to fasten a 1"X 11" Bent Plate. Per Drawing 5613-M-450-105 SH. 3, there are a quantity of 8 bolts installed on this plate. Due to the rigidity of the plate, the tension acting on the nuts and bolts is evenly distributed. As such, there is redundancy and margin in the case of a single nut should fail. However, this is not a likely possibility in the near term as the corrosion is minimal at this time.

Conclusion The CCW Head Tank 3T216 can meet its design basis functions, and the conditions described are not a personnel safety concern at this time.

However, changing the identified corroded bolts and installing weldment as required in the design drawing is recommended.

Attachment 1 Engineering Evaluation: PTN-ENG-SESJ-23-004 Rev. 0 EC-298869 Rev. 0 Page 4 of 5 FORM OAR-1 OWNER'S ACTIVITY REPORT TABLE 2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Code Item Description Date Repair/Replacement Class Description Of Work Completed Plan Number Replaced 1 RV-3-551A 4/16/2023 RR40805683 Valve Replaced 1 RV-3-551 B 4/16/2023 RR40805684 Valve Replaced 1 RV-3-551C 4/16/2023 RR40805685 Valve Replaced 1 Pump 3P200 Bolting and 4/24/2023 RR40808611 Rotor Seal Table Replaced 1 4/23/2023 RR40876697 L-4 and L-5 Fitting Replaced Seal Table 1 Fitting and 4/26/2023 RR40876705 H-6 Conduit Replaced 2 FE-3-127 4/25/2023 RR40625114 Bolting Replaced 2 CV-3-2900 4/23/2023 RR40805631 Bolting Replaced 2 RV-3-1403 4/15/2023 RR4080725 Valve

Attachment 1 Engineering Evaluation: PTN-ENG-SESJ-23-004 Rev. 0 EC-298869 Rev. 0 Page 5 of 5 FORM OAR-1 OWNER'S ACTIVITY REPORT TABLE 2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Code Item Description Date Repair/Replacement Class Description Of Work Completed Plan Number Replaced 2 3S8A 4/28/2023 RR40878425 Valve Replaced 3 Pump 3P209 3/17/2023 RR40775600 Pump Replaced 3 RV-3-1425 4/24/2023 RR40805678 Valve Replaced 3 RV-3-707 4/20/2023 RR40805686 Valve Replaced Valve, 3 3-50-311 Expansion 4/28/2023 RR40811955 Joint, Elbow and Boltinq Replaced Valve, 3 3-50-331 Expansion 4/26/2023 RR40811957 Joint, Elbow and Boltinq Replaced 3 Pump 3P9B 4/27/2023 RR40819269 Pump Replaced 3 Pump 3P9C 4/27/2023 RR40832739 Bolting