Text
November 25, 2019 L-2019-204 10 CFR 50.36 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C. 20555-0001 Re: Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 Wastewater Permit Number FL0001562 Request for Use and Approval of Vapor Infusion Technology 90-Day Trial - Notification In accordance with Section 3.2.3 of the Turkey Point Units 3 and 4 Environmental Protection Plan (Appendix B of Renewed Facility Operating Licenses DPR-31 and DPR-41), Enclosure 1 to this letter provides a copy of the request for approval to use vapor infusion technology for bio-fouling control. Turkey Point will begin a ninety (90) day trial use of aeration with vapor infusion (bubbles comprised of iodine vapor and/or cupric or ferric corrosion inhibitors) to investigate its effectiveness against bio-fouling, mineral-fouling, and corrosion in the heat exchangers. The trial run will utilize a trial skid and potentially an actual heat exchanger, depending on initial trial skid results.
On November 20, 2019, the Florida Department of Environmental Protection issued approval of the 90-day trial use of vapor infusion technologies to reduce heat exchanger fouling and corrosion in Units 3 and 4. In accordance with Section 3.2.2 of the Turkey Point Units 3 and 4 Environmental Protection Plan (Appendix B of Renewed Facility Operating Licenses DPR-31 and DPR-41), Enclosure 2 provides a copy of the approval.
Should there be any questions, please contact Mr. Robert Hess, Turkey Point Licensing Manager, at 305-246-4112.
p Site Director Turkey Point Nuclear Plant Enclosures cc: USNRC Regional Administrator, Region II USNRC Senior Resident Inspector, Turkey Point Plant Florida Power & Light Compa*ny 9760 SW 344 St Homestead, FL 33035
ENCLOSURE 1 TO L-2019-204
Enclosure 1 to L-2019-204 FPL Request to Use Vapor Technology for Bio-Fouling Control [e:mail dated 11/4/2019]
From: Pandya, Meghna Sent: Monday, November 04, 2019 8:47 AM To: Wall, Frank (Frank.Wall@FloridaDEP.gov) <Frank.Wall@FloridaDEP.gov>
Subject:
FW: PTN Vapor Infusion Trial Run Info
- Frank, FPL Turkey Nuclear wants to do a 90 day trail using the vapor technology for bio-fouling control described below. Please let me know if the given information is sufficient to get a trail approval. I will call you later today to discuss this further.
- Thanks, Meghna Pandya Environmental Specialist Florida Power & Light Company l Environmental Services 700 Universe Blvd (JES/JB)
Juno Beach, FL 33408 Office: 561-691-3074 Meghna.Pandya@fpl.com 1
From: Eguino, Richard <Richard.Eguino@fpl.com>
Sent: Wednesday, October 30, 2019 12:39 PM To: Pandya, Meghna <Meghna.Pandya@fpl.com>
Cc: Reid, Michael <Michael.Reid@fpl.com>
Subject:
PTN Vapor Infusion Trial Run Info Hi Meghna. Following up on our conversation this morning:
PTN would like to begin a ninety (90) day test period of aeration with vapor infusion (bubbles comprised of iodine vapor and/or cupric or ferric corrosion inhibitors) to investigate its effectiveness against bio-fouling, mineral-fouling, and corrosion in the heat exchangers. The trial run would utilize a trial skid and potentially an actual heat exchanger depending on initial trial skid results.
The vendor explained that this technology was used at the Island Energy oil refinery at Oahu, Hawaii as well as at-sea ships.
Please find attached a PDF from the vendor with more details on the process, and SDSs for the additives that will be tested. Please note only one of the iodine resins will be usedmy understanding is that they serve identical functions but are from different manufacturers. Also, below is a table with pertinent information for the additives per the vendor. The dosage and effluent in the table is per unit; in other words, if the trial skid and the heat exchanger are both tested the numbers would apply to each set-up individually.
Please let me know if you would like a teleconference with the vendor to discuss further and I will arrange.
2
Effluent Additive Purpose Dosage Frequency Concentration Gaseous and aqueous copper and yellow metal < 0.04 g (total 60 Wintrol Benzotriazole < 100 ppb corrosion resistance, grams/month) oxygen capture Gaseous oxygen replacement, decreased Nichem Iodine Resin -
bubble solubility, OR- Hybrid increased bubble Two three-minute infusions per hour Technologies Iodine density, reduced bubble Resin H-465 < 0.02 g (total 30 gas mass transfer, < 200 ppb each grams/month) each increased bubble weight VPCI-609 Gaseous and aqueous ferrous metal corrosion VPCI-609S resistance, oxygen capture Many thanks, Richard Eguino Sr. Environmental Specialist Turkey Point Nuclear Power Plant 9760 SW 344th St Florida City 33035 305-246-6135 (o) 305-283-8687 (m) 3
SAFETY DATA SHEET (SDS) 1-IDENTIFICATION Wintrol Benzotriazole Product code: 30BT100, Wintrol B-F, Wintrol B-P, Wintrol B-G, Wintrol B-N, Wintrol B-E, Wintrol B-FG Chemical family: Triazole Recommended use: Yellow metal corrosion inhibitor Wincom, Inc.
11444 Deerfield Road Suite B Blue Ash, Ohio 45242 Information telephone #: (513) 936-0185 (7:30 AM to 4 PM, EST, Monday to Friday) 24 Hr. emergency telephone #: CHEMTEL (US): (800) 255-3924 CHEMTEL (Intl): 01-813-248-0585 Revision date: 10/06/2016
- All non-emergency questions should be directed to customer service @ (513) 936-0185 or customerservice@wincom-inc.com
- 2 - HAZARDS IDENTIFICATION Classification of chemical:
White to light yellow flake, granules or powder This material is classified as hazardous under OSHA regulations (29CFR 1910.1200) (Hazcom 2012)
Hazard classification:
Acute Toxicity, Oral - Category 4, H302 Acute Toxicity, Inhalation - Category 4, H332 Eye Irritation - Category 2A, H319 Label elements:
Hazard Pictogram:
Signal word: Warning Hazard statements:
H302 + H332 Harmful if swallowed or if inhaled H319 Causes serious eye irritation Precautionary statements:
P264 Wash contact area thoroughly after handling P270 Do not eat, drink or smoke when using this product P301 + P312 IF SWALLOWED: Call a POISON CENTER/doctor if you feel unwell P330 Rinse mouth P261 Avoid breathing dust P271 Use only outdoors or in a well-ventilated area P304 + P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON P312 CENTER/doctor if you feel unwell P280 Wear protective gloves/protective clothing/eye protection/face protection P304+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing P337-P313 If eye irritation persists: Get medical advice/attention P501 Dispose of contents/containers in accordance with local regulations 3 - COMPOSITION/INFORMATION ON INGREDIENTS Chemical name CAS # Concentration 1,2,3-Benzotriazole 95-14-7 >99.0 4 - FIRST AID MEASURES Description of first aid measures:
Inhalation: IF INHALED: Remove from exposure, get fresh air. If problems remain or occur later, get medical attention. Self-Contained Breathing Apparatus should be worn if exposed to large quantities.
Skin
Contact:
IF ON SKIN: Wash off skin thoroughly with water. Remove contaminated clothing and wash before re-use.
Eye
Contact:
For eye contact, flush eyes with water for 15 minutes. Get medical attention if irritation persists.
Ingestion: Wash out mouth thoroughly with water and give plenty of water to drink. DO NOT induce vomiting unless told by a medical professional. Obtain medical attention.
Symptoms and effects, both acute and delayed:
Acute:
Eye
Contact:
redness, itching, burning or swelling Skin
Contact:
redness, itching, burning or swelling Ingestion: pain, vomiting, diarrhea, or collapse Inhalation: irritation to respiratory tract Chronic: No data available 5 - FIRE-FIGHTING MEASURES Extinguishing media:
Suitable extinguishing media: Carbon dioxide, dry-chemical or universal type foam Unsuitable extinguishing media: Do not use a solid water stream as it may scatter and spread fire Special hazards arising from substance: Incompatible with oxidizing agents Material name: Wintrol Benzotriazole Revision date: 04/06/2018
Hazardous combustion products: none Special protective equipment and precautions for firefighters: Use Carbon Dioxide Extinguisher (suitable for class B and C fires) or Multi-Purpose Dry Chemical Extinguisher (suitable for class A, B and C fires).
6 - ACCIDENTAL RELEASE MEASURES Personal precautions, protective equipment and emergency procedures: All persons dealing with the clean-up should wear the appropriate chemically protective equipment. Keep others away from spill. Restrict access to area until the spill has been cleaned up.
Methods and material for containment and cleaning up: Use proper personal protective equipment. Isolate and secure the area and follow the appropriate emergency guidelines. If local high concentration of airborne mist occurs, dilute spill with plenty of water and ventilate to disperse mist-laden air. Sweep up spill and reclaim or place in a covered waste disposal container. Report spill to proper authorities.
7 - HANDLING AND STORAGE Precautions for safe handling: Obtain special instructions before use. Wear proper personal protective equipment. Use only in well ventilated areas. Avoid contact with skin, eyes and clothing. Keep away from heat, sparks and open flame.
Conditions for safe storage: Store in a cool, dry, ventilated area away from any heat source. Storage area should be clearly identified and free of obstruction. Keep containers tightly closed and in an upright position when not in use.
Incompatible materials: Oxidizing agents Section 7 notes: Change contaminated clothing. Wash hands well after working with substance.
8 - EXPOSURE CONTROLS/PERSONAL PROTECTION Exposure limits: Limits have not been established by OSHA and ACGIH Exposure controls:
Ventilation and engineering measures: Use ventilation if possible, e.g., fans or exhaust systems to keep vapor levels below recommended exposure limits. In case of insufficient ventilation wear suitable respiratory equipment.
Respiratory protection: If good ventilation is not available, wear a respiratory device approved by NIOSH/MSHA for protection against organic vapors, mists and dust. If handling large quantities, use a certified SCBA apparatus.
Eye protection: Wear safety glasses with un-perforated side shields.
Skin protection: Wear chemical resistant gloves for long and repeated contact. Contaminated clothing and shoes should be cleaned before reusing.
Other protective equipment: Safety shower/eye wash General hygiene considerations: Acceptable industrial hygiene practices should be maintained.
Material name: Wintrol Benzotriazole Revision date: 04/06/2018
9 - PHYSICAL AND CHEMICAL PROPERTIES Appearance: White to light yellow flake, granules, pellets or powder Odor: Slightly Sweet Odor Odor threshold: Data currently unavailable pH: 5.5 - 6.0 Melting point: 98.5 °C Boiling point: 204 °C @ 15 mm Hg Vapor pressure (mmHg): 4.0X01-2 @ 20 °C Vapor density: 4.1 Evaporation rate: Non-volatile Flash point: 195°C; 383°F Upper/lower flammability limits: 2.4% by volume (lower)
Solubility in water: 2.0 wt % @ 25°C Other solubilities: Soluble in benzene, toluene and N,N-dimethylformamide and ethanol Percent volatile: None Log P (octanol-water): Log Kow: 1.44 Autoignition temperature: 400°C; 752°F Decomposition temperature: Data currently unavailable Gibbs energy: 442.65 kj/mol Section 9 notes: The above chemical properties are a compilation of data from the NTP, Chemdraw and Wincom, Inc.
10 - STABILITY AND REACTIVITY Reactivity: Not normally reactive Stability: Stable under normal conditions Incompatible materials: Oxidizing Agents Hazardous decomposition products or by-products: FIRE: Nitrogen oxides, carbon monoxide and carbon dioxide. HCN in reducing atmospheres Possibility of hazardous reactions: Hazardous polymerization does not occur.
11 - TOXICOLOGICAL INFORMATION Information on likey routes of exposure:
Routes of entry - inhalation: yes Routes of entry - skin & eye: yes Routes of entry - ingestion: yes Routes of entry - skin absorption: yes Potential health effects:
Signs and symptoms of short term (acute) exposure:
Signs and symptoms - inhalation: cough, difficulty breathing, may be irritating to respiratory tract; in severe cases respiratory irritation can progress into pulmonary edema Signs and symptoms - ingestion: pain, vomiting, diarrhea and collapse Signs and symptoms - skin: redness, itching, burning and swelling Signs and symptoms - eyes: irritation, pain, swelling, lacrimation and photophobia Potential chronic health effects: No observed chronic health effects Mutagenicity: Not considered to be mutagenic Carcinogenicity: This product is not listed on OSHA, NIOSH, IARC or NTP lists as cancer-causing Material name: Wintrol Benzotriazole Revision date: 04/06/2018
Reproductive effects: No evidence of pathology in reproductive organs Sensitization to material: Not expected to be a skin sensitizer No data available to indicate material may be a respiratory sensitizer Specific target organ effects: Not expected to produce specific target organ toxicity from repeated exposure Medical conditions aggravated by overexposure: No data found Toxicological data:
Oral LD50 (Rat): 560 mg/kg Dermal LD50 (Rabbit): > 2,000 mg/kg Inhalation LC50: 1.5 mg/L In a test for primary skin irritation and sensitization on guinea pigs, 1-H-benzotriazole was at most mildly irritating in concentrations up to 50% in ethanol and was not a sensitizer. The dry powder is severely irritating to the rabbit eyes (0.1 ml unwashed) but prompt water washing reduces irritation considerably. [Clayton, G.D., F.E. Clayton (eds.) Patty's Industrial Hygiene and Toxicology. Volumes 2A, 2B, 2C, 2D, 2E, 2F: Toxicology. 4th ed. New York, NY: John Wiley & Sons Inc., 1993-1994., p. 3347(NTP WEBSITE)
Human toxicity levels: None found 12 - ECOLOGICAL INFORMATION Ecotoxicity: Acute toxicity of benzotriazole:
Toxicity to fish: LC50/96 hr/B. rerio = 100 mg/l Toxicity to crustacean: EC50/48 hr/D. magna = 91-141 mg/l Toxicity to algae: EC50/72 hr/S. subspicatus = 231 mg/l Persistence and degradability: readily biodegradable Bioaccumulation potential: Log Kow: 1.44 Mobility in soil: expected to have high mobility in soil; affected by pH ("1,2,3-Benzotriazole-National Library of Medicine HSDB Database." U.S. National Library of Medicine. N.p., 01 Jan. 1993. Web. 30 Apr. 2013. <http://toxnet.nlm.nih.gov/cgi-bin/sis/search/r?dbs+hsdb:@term+@na+1,2,3-BENZOTRIAZOLE>.)
13 - DISPOSAL CONSIDERATIONS Waste disposal method: Dispose of in accordance with federal, state and local regulations.
14 - TRANSPORTATION INFORMATION DOT classification: This product is currently not a DOT controlled material in the United States.
15 - REGULATORY INFORMATION U.S. federal regulations TSCA (Toxic Substance Control Act): 8(b) inventory: Benzotriazole-1,2,3 EINECS: This product is on the European Inventory of Existing Commercial Chemical Substances 202-394-1 Worldwide Chemical Inventory Status: USA,TSCA,CANADA and DSL Material name: Wintrol Benzotriazole Revision date: 04/06/2018
California Proposition 65: None of the components in Wintrol B are in the current P-65 chemicals list.
HMIS hazard classification Health: 2 Flammability: 1 Physical hazard: 0 Protection: E National Fire Protection (U.S.A.)
Health: 2 Flammability: 1 Reactivity: 0 16 - OTHER INFORMATION Preparation information: Prepared on the 21st of November 2013 Legend: ACGIH: American Conference of Governmental Industrial Hygienists CAS: Chemical Abstract Service CFR: Code of Federal Regulations DOT: Department of Transportation DSL: Domestic Substance List (Canada)
EC: Effective Concentration EINECS: European Inventory of Existing Commercial chemical Substances EPA: Environmental Protection Agency HMIS: Hazardous Material Identification System IARC: International Agency for Research on Cancer LC: Lethal Concentration LD: Lethal Dose NIOSH: National Institute of Occupational Safety and Health NTP: National Toxicology Program OSHA: Occupational Safety and Health Administration SCBA: Self Contained Breathing Apparatus SDS: Safety Data Sheet/Material Safety Data Sheet DISCLAIMER:
While the descriptions, designs, data and information contained herein are presented in good faith and believed to be accurate, it is provided for your guidance only. Because many factors may affect processing or application/use, we recommend that you make tests to determine the suitability of a product for your particular purpose prior to use. No warranties of any kind, either express or implied, including warranties of merchantability or fitness for a particular purpose, are made regarding products described or designs, data or information set forth, or that the products, designs, data or information may be used without infringing the intellectual property rights of others. In no case shall the descriptions, information, data or designs provided be considered a part of our terms and conditions of sale. Further, you expressly understand and agree that the descriptions, designs, data, and information furnished by Wincom hereunder are given gratis and Wincom assumes no obligation or liability for the description, designs, data and information given or results obtained, all such being given and accepted at your risk. Data obtained from EPA, eChemPortal, Benzotriazoles Category Justification and Testing Rationale. Rep.,2001. Print., "1,2,3-Benzotriazole-National Library of Medicine HSDB Database." U.S. National Library of Medicine. N.p., 01 Jan. 1993. Web. 30 Apr. 2013., and Wincom Lab.
Material name: Wintrol Benzotriazole Revision date: 04/06/2018
MSDS Iodinated Resin Iodine-based water purifying media Water (Date Issued: 01.04.16)
- 1. IDENTIFICATION OF THE PREPARATION Product Name IODINATED RESIN Application Iodine removal from drinking water Company NICHEM SOLUTIONS Identification Plot No. A-387, Rd. No.28, Ramnagar, Wagle Estate, Thane (W)-
400604.Maharashtra, INDIA.
Contact Details Telefax: +91-22-25821587/88 Email: info@nichem.solutions Website: www.nichem.solutions
- 2. COMPOSITION OF INGREDIENTS Description Contents CAS No. HS Code Anion Exchange Resin loaded with Iodine. Cross Linked 55844-94-5 39140090 Styrene Resin
- 3. HAZARD IDENTIFICATION Contact with Eyes: May cause irritation.
Contact with Skin: May cause yellowing Ecological Hazards: Oxidizing material, should not be exposed to high pH
- 4. FIRST AID MEASURES General information: Bring affected persons out of danger area. Observe self-protection (body protection, eye protection, respiratory protection).
After skin contact: Remove contaminated clothing. Remove particles and wash affected area with water.
After eye contact: With eye held open, thoroughly rinse immediately with plenty of water for at last 15 minutes. Remove contact lenses if easily possible. Seek medical attention if needed.
After swallowing: Rinse mouth with water. Induce vomiting & seek medical help.
- 5. FIRE FIGHTING MEASURES In case of fire, use foam, carbon dioxide or dry agent.
Substance evolves toxic fumes if ignited on purpose, wear self-contained breathing apparatus (See section 10).
Wear full protective clothing including chemical protection suit.
Prevent run-off water from entering drains if possible.
If polluted water reaches drainage systems or water courses, immediately inform appropriate authorities.
- 6. ACCIDENTAL RELEASE MEASURES Personal precautions: Keep people away. Floor may become slippery, take care to avoid falls.
Environmental precautions: Do not allow to enter public sewages and water courses.
NICHEM Solutions, Thane (W), India Email- info@nichem.solutions, Website: http://nichem.solutions, Tel: 022-2582 1588
Clean-up actions: Wet with water and sweep-up and transfer to plastic containers for recovery or disposal as advised in Section 13.
- 7. HANDLING AND STORAGE HANDLING: Information for safe handling Special care is required for handling of the product to prevent contamination. Protect from impurities. Never return spilt product to original container. The usual precautions for handling chemicals should be observed. Risk of static discharge from dry beads.
STORAGE CONDITION: Store above 0°C in wet conditions in water. Keep at temperatures not exceeding 40°C. Avoid dehydration (when rewetted volume may increase and cause a rupture of the packaging if not allowed to swell. Keep only in the original container.
- 8. EXPOSURE CONTROL/PERSONAL PROTECTION General Protective and hygienic measures Protection of hands: Wear protective gloves made of PVC, neoprene or natural rubber.
Eye protection: Wear safety goggles.
Body protection: Change work clothes immediately if spilled with the product.
- 9. PHYSICAL & CHEMICAL PROPERTIES Physical Properties Form Spherical beads Colour Pitch Black Odor Strong Iodine Odor Chemical Properties Base Anion Exchange Resin loaded with Iodine Bulk Density (Wet basis) 1.50 - 1.60 gm/cc (Dry basis) 1.2 - 1.3 gm/cc Flash Point Not Applicable Flammability point The preparation starts burning over 230°C only if ignited Auto-Ignition Temp. Over 500°C Solubility Insoluble in water & solvents Stability Stability at ambient temperature under normal conditions of use
- 10. STABILITY AND REACTIVITY Stable at Room Temperature Conditions to be avoided: Prolonged exposure to air & sunlight.
Substances to be avoided: Incompatible with strong reducing agents. Contact with strong reducing agents, especially hydrazine, sodium metabisulphite and aldehydes may cause severe reaction.
Reactivity: Combustion products may include monomers, residual organics, carbon and iodine.
Solubility: It is insoluble in water & solvents
- 11. TOXICOLOGICAL INFORMATION Chronic Toxicity has not been demonstrated by POLYSTYRENE COMPOUNDS.
They are not listed as a carcinogen by MAK, IARC, NTP, OSHA, and ACGIH.
Carcinogenicity: No evidence of carcinogenic effects Teratogenicity: No evidence of teratogenic effects Mutagenicity: No evidence of mutagenic effects The LD50 value (Oral: Rat) is >2000 mg/kg body weight.
NICHEM Solutions, Thane (W), India Email- info@nichem.solutions, Website: http://nichem.solutions, Tel: 022-2582 1588
- 12. ECOLOGICAL INFORMATION Eco-toxicity: Not known Mobility: Insoluble in water & solvents Persistence and Biodegradability: Not readily biodegradable Risk of bioaccumulation: None Other adverse effects: None
- 13. DISPOSAL CONSIDERATIONS Recommendation: Product The product as delivered is a special, hazardous waste. The used product, fully loaded with non-hazardous ions is a non-hazardous special waste.
In any case,please dispose-off the product according to local,regional & national regulations.
Unclean packaging:
Rinse empty containers with water prior to disposal. Take decontaminated packaging to local recycling centre.
- 14. TRANSPORT INFORMATION Adsorbent resins as supplied are not classified as hazardous for transport. Product is safe for transport by Roadways, Airways or Waterways. No special precautions need to be taken for the product with adequate packing in plastic bottles/containers - as mentioned in Section 7.
Not classified as dangerous for transport as per IATA guidelines Classification: None
- 15. REGULATORY INFORMATION Labeling of substances in line with EC Directive 67/546/EEC and amendment.
Risk phrases: R36 - Irritating to eyes Safety phrases:
S2 - Keep out of reach of children S7 - Keep container tightly closed S26 - In case of contact with eyes, rinse immediately with plenty of water and seek medical advice S28 - After contact with skin, wash immediately with plenty of water S36/37/39 - Wear suitable protective clothing, gloves, eye/face protection S45/46 - If swallowed or in case of accident or if you feel unwell, seek medical advice immediately
- 16. OTHER INFORMATION Disclaimer: NICHEM SOLUTIONS has internally & externally verified the effectiveness &
efficacy of its products by a standard protocol. We expect to reproduce the same results at customers end by adopting same protocol. We take responsibility for the uniform quality of our products. However, NICHEM SOLUTIONS will not be responsible for any consequential liability of any nature for whatsoever reason.
NICHEM Solutions, Thane (W), India Email- info@nichem.solutions, Website: http://nichem.solutions, Tel: 022-2582 1588
HYBRID TECHNOLOGIES CORPORATION SAFETY DATA SHEET SECTION 1: PRODUCT AND COMPANY INFORMATION PRODUCT TYPE: Trimethylamine functionalized chloromethylated copolymer of styrene and divinylbenzene in the iodide form.
PRODUCT NAME: Iodinated Resin H-465 COMPANY ID: Hybrid Technologies Corporation 3814 110th St., Karlstad, MN 56732 USA TELEPHONE NUMBER: INFORMATION: CORPORATE 218-436-3155 I MEDICAL EMERGENCY: CHEMTREC 800-424-9300 TRANSPORTATION EMERGENCY: CHEMTREC 800-424-9300 DATE PREPARED: May 15, 2015 I REVISION: 0 SECTION 2: HAZARD(S) IDENTIFICATION HMIS RATINGS NFPA RATINGS GUIDE 4 - EXTREME/SEVERE 3 - HIGH/SERIOUS 2-MODERATE 1-SLIGHT 0-MINIMUM W-WATER REACTIVE OX - OXIDIZER PICTOGRAM SIGNAL WORD HAZARD STATEMENT Warning May cause slight eye and skin irritation.
PRECAUTIONARY STATEMENT(S)
PREVENTION Wear eye and skin protection.
RESPONSE IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. In case of contact with skin, wash with mild soap and water. If irritation persists, see a physician .
STORAGE Cool, dry, away from sunlight.
OTHER HAZARDS NONE (1 )
HYBRID TECHNOLOGIES CORPORATION SAFETY DATA SHEET SECTION 3: COMPOSITION/ INFORMATION ON INGREDIENTS PERCENT BY WEIGHT COMMON NAME CAS NO. IMPURITIES (Ingredient/ Component) 46% Iodine/ 12 7553-56-2 None 54% Styrene, divinylbenzene 60177-39-1 None and ethylstyrene copolymer, chloromethyl trimethylamine functionalized in the chloride form SECTION 4: FIRST - AID MEASURES NECESSARY FIRST Alf> INSTRUCTIONS INHALATION FIRST AID Remove victim to fresh air and keep at rest in a position comfortable for breathing. In case of inhalation of decomposition products in a fire, symptoms may be delayed.
The exposed person may need to be kept under medical surveillance for 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />.
SKIN CONTACT FIRST AID Wash contaminated skin with mild soap and water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur.
EYE CONTACT FIRST AID Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Seek medical attention if irritation persists.
INGESTION FIRST AID If material has been swallowed and the exposed person is conscious, drink large quantities of milk or water, transport to hospital and observe for signs of Iodine toxicity. If no hospital is available, induce vomiting, drink large quantities of milk or water and observe for adverse reaction. If unconscious or convulsing, transport to hospital immediately. Never give anything by mouth to an unconscious person.
DESCRIPTION OF M0ST IMPORTAI\IT SYMPTOMS No additional information available RECOMMENDATIONS F-OR IMMEDIATE MEDICAL CARE No additional information available
( 2)
HYBRID TECHNOLOGIES CORPORATION SAFETY DATA SHEET SECTION 5: FIRE - FIGHTING MEASUURES SUITABLE EXTINGUISHING MEDIA Use an extinguishing agent suitable for the surrounding fire.
In case of fire, use water spray (fog), carbon dioxide, foam or dry chemical.
UNSUITABLE EXTINGUISHING MEDIA None known SPECIFIC HAZARDS Iodine fumes and iodine compounds, alkybenzenes, vinyl benzenes, naphthalene benzealdehydes, phenol, carbon dioxide, organ ic amines, nitrogen oxides, ammonia, and oxides of sulfur are possible combustion products.
PERSONAL PROTECTIVE EQUIPMENT Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face -piece operat ed in positive pressure mode .
SECTION 6: ACCIDENTAL RELEASE MEASURES PERSO>NAL PRECA,UTIONS, PROTECTIVE EQUIPMENT AND EM~RGEl\!<::Y PROCEDURES PERSONAL PRECAUTIONS No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or wal k through spilled material. Put on appropriate personal protective equipment. Ha zard of slipping on spelled product.
ENVIRONMENTAL PRECAUTIONS Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air).
CONTAINMENT AND CLEAN-UP Move containers from spill area. Sweep up material and place in a designated, labeled waste container. Note: see Section 1 for emergency contact information and Section 13 for waste disposal. Prevent entry into sewers, water courses, basements of confined areas.
OTHER INFORMATION None (3 )
HYBRID TECHNOLOGIES CORPORATION SAFETY DATA SHEET SECTION 7: HANDLING AND STORAGE PRECAUTIONS FOR SAFE HANDLING Remove contaminated clothing and protective equipment before entering eating areas. Workers should wash hands and face before eating, drinking and smoking. Put on appropriate personal protection equipment. Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed.
CONDITIONS FOR SAFE STORAGE Store between the following temperatures: 1 to 40°C (33.8 to 104°F). Store in accordance with local regulations. Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Keep container tightly closed and sealed until ready for use.
Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers. Use appropriate containment to avoid environmental contamination. Empty containers or liners may retain some product residues. It is recommended to store iodinated resins at temperatures above the freezing point of water. If the resin should become frozen, the resin should not be mechanically handled and should be left to thaw out gradually at ambient temperature. It must be completely thawed before handling or use. No attempt should be made to accelerate the thawing process.
SECTION 8: EXPOSURE CONTROLS/ PERSONAL PROTECTION ENGINEERING CONTROLS Good general ventilation should be sufficient to control worker exposure to airborne contaminants.
RESPIRATORY PROTECTION Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator.
SKIN PROTECTION Wear suitable protective clothing and gloves. Suitable protective footwear. Maintain eye wash station.
EYE /FACE PROTECTION If contact with product is possible, wear safety glasses with side shields.
RESULT OSHAS HR ACGIH TLV 8 HR mg/m3 mg/m3 EXPOSURE LIMITS/ GUIDELINES 1 mg/m 3 (0.1ppm) 0.1 mg/m 3 (0.01 ppm)
RESULT 0SHA8HR ACGIH TLV 8 HR 3
mg/m mg/m3 PARTICULATES NOT OTHERWISE N/A REGLATED {PNOR)
PARTICULATES NOT OTHERWISE N/A CLASSIFIED {PNOC)
( 4}
HYBRID TECHNOLOGIES CORPORATION SAFETY DATA SHEET SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES APPEARANCE Solid spherical beads MOLECULAR WEIGHT N/A COLOR Purplish-black ODOR THERSHOLD No data available ODOR Slight iodine VAPOR PRESSURE 0.3 mmHg@ 20°c (68.0°F)
PH VALUE N/A VAPOR DENSITY Not available MELTING POINT N/A RELATIVE DENSITY 2.15 g/cm 3 (20°c (68.0°F)
FREEZING POINT N/A SOLUBILITY 0.2 - 5.0 mg/L@ 20°C (68.0°F)
INITIAL BOILIING PONT N/A PARTITION COEFFICEINT Not available FLASHPOINT N/A AUTO IGNITION TEMP. Over 500°C (932°F)
EVAPORATON RATE N/A DECOMP. TEMP. No data available FLAMMABILITY Over 230° Conly if ignited. V ISCOSITY N/A UEL N/A LEL N/A SECTION 10: STABILITY AND REACTIVITY REACTIVITY None when handled and stored properly. Slowly reacts with solid metals.
CHEMICAL STABILITY The product is stable under normal ambient temperature and conditions while in storage and being handled.
POSSIBILITY OF HAZARDOUS REACTIONS Heat, direct sunlight, incompatible materials.
CONDITIONS TO AVOID INCOMPATIBLE MATERIALS Ammonia solutions, metal powders, sulphur, alkali metals, reducing agents, combustible materials, metal acetylides, antimony, ammonium hydroxide, acelytene, phosphorous, magnesium, zinc, sodium, potassium, lithium, liquid chlorine, metal carbides, aluminum, fluorine.
HAZAROUS DECOMPOSITION PRODUCTS Depending upon temperature, air supply and the presence of other m aterials, decomposition products can include: sulfur oxides, iodine vapor and iodine compounds, carbon monoxide, carbon dioxide, benzene compounds, nitrogen oxides, hydrocarbons, organic nitrates, styrene.
INSTABILITY TEMPERATURE Not available POLYERIZATION Will not occur.
CORROSIVITY Weak corrosive to most grades of steel.
( 5)
HYBRID TECHNOLOGIES CORPORATION SAFETY DATA SHEET SECTION 11: TOXICOLOGICAL INFORMATION IODINE/ CAS NO. 7553-56-2 LDSO ORAL RAT 14000 mg/kg LDSO DERMAL RAT 220 mg/kg ATE US (ORAL) 14000 mg/kg bodyweight ATE US (DERMAL) 220 mg/kg bodyweight CARCINOGENICITY Iodine - Not listed as a carcinogen by ACGIH, IARC, NTP, or CA Prop 65.
IODINATED RESIN H-465 SKIN CONTACT Does not cause irritation with normal handling.
EYE CONTACT Iodinated resin beads in the eye can cause irritation, pain, redness and tearing of eyes.
INGESTION ACUTE No specific data CHRONIC No specific data INHALATION ACUTE No specific data CHRONIC No specific data REPRODUCTIVE EFFECTS No specific data NEUROTOXICITY No specific data OTHER EFFECTS No specific data TARGET ORGANS No specific data SECTION 12: ECOLOGICAL INFORMATION The material in its original state, is not harmful to the environment.
SECTION 13: DISPOSAL CONSIDERATIONS SPILL/ LEAK Isolate spill area to prevent falls as material can be a slipping PROCEDURES hazard. Avoid contact with eyes and skin. Material is heavier than water and has limited water solubility. It will collect on the lowest surface.
CLEANUP Clean up floor area. Sweep up.
Regulatory Requirements: Follow all applicable Federal, State, Local, or Provincial regulations.
REGULATORY If discarded in its purchased form, this product would not be REQUIREMENTS a hazardous waste either by listing or by characteristic.
However, under RCRA, it is the responsibility of the product user to determine at the time of disposal, whether a material containing the product or derived from the product should be classified as a hazardous waste. (40 CFR 261.20-24).
DISPOSAL The generation of waste should be avoided or minimized wherever possible. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. This material and its container must be disposed of in a safe way.
Empty containers or liners may retain some product residues.
Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers. Do not incinerate or burn product waste and its containers. Waste disposal should be in accordance with existing federal, state, provincial and or local environmental control laws.
( 6)
HYBRID TECHNOLOGIES CORPORATION SAFETY DATA SHEET SECTION 14: TRANSPORT INFORMATION LAND - DOT UN/NA IDENTIFICATION NUMBER: Not regulated UN-PROPER SHIPPING NAME: Not regulated TRANSORT HAZARD CLASS: Not regulated PACKING GROUP: Not regulated MARINE POLLUTANT: Not regulated HAZARD CLASS: Not regulated WATER- IMO/ IMDG UN/NA IDENTIFICATION NUMBER: Not regulated UN-PROPER SHIPPING NAME: Not regulated TRANSORT HAZARD CLASS: Not regulated PACKING GROUP: Not regulated MARINE POLLUTANT: Not regulated AIR - ICAO / IATA UN/NA IDENTIFICATION NUMBER: Not regulated UN-PROPER SHIPPING NAME: Not regulated TRANSORT HAZARD CLASS: Not regulated PACKING GROUP: Not regulated MARINE POLLUTANT: Not regulated SECTION 15: REGLATORY INFORMATION OSHA None OSHA None CAA None CERCLA None SARA None SARA HAZARD N/A CATEGORIES 311 / 312 TSCA None
( 7)
HYBRID TECHNOLOGIES CORPORATION SAFETY DATA SHEET SECTION 16: OTHER INFORMATION USERS RESPONSIBILITYY: A bulletin such as this cannot be expected to cover all possible individual situations. As the user has the responsibility to provide a safe workplace, all aspects of an individual operation should be examined to determine if or where, precautions are required. Any health hazard and safety information herein should be passed on to your customers or employees.
DISCLAIMER: Hybrid Technologies Corporation provides the information contained in the (SOS) and is based upon information and tests believed to be accurate and represents the best information currently available to us. However, since conditions of handling and use are beyond our control, Hybrid Technologies Corporation makes no guarantee of results and assumes no liability for damages incurred by use of this material. All chemicals may present unknown health hazards are described herein, we cannot guarantee that these are the only hazards which exist. Final determination of suitability of the chemical is the sole responsibility of the user.
HYBRID TECHNOLOGIES CORPORATION MAKES NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR IMPLIED, !INCLUDING WITHOUT LIIMITATION ANY WARRANTIES OF MERCHANTABILIITY, FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THE INFORMATION SET FORTH HEREIN OR THE PRODUCT TO WHICH THE INFORMATION REFERS. ACCORDINGLY, HYBRID TECHNOLOGIES CORPORATION WILL NOT BE RESPONSIBLE FOR DAMAGES OR EXPENSES ARISING OUT OF OR IN ANY WAY CONNECTED WITH THE HANDLING, STORAGE, USE OR DISPOSAL OF THIS PRODUCT RESULTING FROM USE OF OR RELIANCE UPON THIS INFORMATION:
REVISION INDICATOR: Revision 0: (This SOS replaces the former MSDS for this product pursuant to OSHA 1910.1200(g) Appendix D. The MSDS for this product should be considered obsolete).
( 8)
VpCI-609/609S Biodegradable Powders Corrosion Inhibiting Powder for Ferrous Metals Patent Pending TOXICOLOGICAL TESTING RESULTS (Performed by Nortech A.S. (Norway))*
- Biodegradability: 100% biodegradable in marine environment, rapidly degradable substance (OECD** 306, BOD 28 Marine test).
- Toxicity: Very low (LD-50 = 5,000 mg oral-rat).
- Bioaccumulation potential: none (OECD Guideline 117).
- Testing performed in accordance with Oslo-Paris com mission protocol
- Organization for Economic Co-Operation and Development TYPICAL USES
- Tubular structures, pipes, and vessels.
- Voids, cavities, and tanks.
- Internal surfaces of compressors, turbines, engines, tanks, boilers, heat exchangers.
- Steam condensate lines, closed circuit heating, and cooling systems
- Equipment during and after hydrostatic testing.
PRODUCT DESCRIPTION
- Parts, components, and completed assemblies during shipping and storage.
VpCI-609 is a water-soluble Vapor phase Corrosion Inhibitor (VpCI)
- Additive to shot-blasting media, wet blasting.
powder for wet or dry corrosion protection of ferrous metals and aluminum.
- Additive to standing water.
VpCI-609 is also available as VpCI-609S (with silica).
PHYSICAL PROPERTIES FEATURES VpCI-609
- Accepted by Cefas as an offshore chemical. Registered under OCNS number 25717 allowing use at 5,000 ppm. Appearance Off white crystalline powder
- Provides liquid, vapor-phase, and interface protection (above the liquid pH 6-7 (1% aqueous solution) level). Solubility in water 15%
- Creates a monomolecular inhibiting layer on metal surface.
- Provides up to 24 months of continuous protection. Bulk Density 38-39 lb/ft3 (0.61-0.63 kg/l)
- Does not contain nitrites, phosphates, or heavy metals.
VpCI-609S ADVANTAGES Appearance White to off white powder pH 5.9-6.9 (1% water)
- Vapor-phase inhibiting action protects inaccessible and recessed surfaces Bulk Density 37-38 lb/ft3 (0.59-0.61 kg/l)
- If the VpCI layer is disturbed by moisture or the opening of an enclosed space, the layer is replenished by continuous vapor redeposition.
METALS PROTECTED
- Prevents future corrosion of precoated and painted surfaces.
- VpCI layer typically does not need to be removed prior to processing
- Carbon steel or use.
- Stainless steel
- If required, powder is easily removed by air gun or water flush.
- Aluminum
- Does not increase alkalinity.
- Other ferrous metals
- Provides economical protection for very large applications.
METHOD OF APPLICATION LIMITATIONS Apply VpCI-609 in dry form by dusting, fogging, or sprinkling. Apply
- Do not use on copper, copper-based alloys, and other soft yellow metals.
VpCI-609 in aqueous form by spray, flush, or immersion. After application Compatibility with non-metalics should be evaluated.
simply cover and close or seal the interior cavity or void (Fogging is easily achieved by using a low pressure air hose and sandblast cup. Large
- Caking of powder may occur when it is exposed to moisture and then conventional sandblasting systems can also be used). dried. The likelihood of this is increased when powder is exposed to high heat and multiple wet/dry cycles. To avoid caking of powder do not over apply or unevenly disperse the dry powder. In aqueous ap-DOSAGE plications make sure powder has been totally dissolved before using.
Over extended periods of protection, this caking may require a more For powder application with average environmental conditions, use 0.3-0.5 involved cleaning prodedure. Contact Cortec for futher details.
ounce (8.5-14 grams) of VpCI-609 per 1 cubic foot (28 liters) of enclosed space (300-500 g/m3). The dosage can be increased for more severe
- Powder is not soluble in hydrocarbon fluids. Rinse powder from vessels conditions. For aqueous submersion or partial submersion applications, before adding hydrocarbon fluid.
consult your Cortec Representative.
- Powder should be removed from the area on each side of weld before METHOD OF REMOVAL welding, or other high temperature processing.
When required, VpCI-609/609S in powder form can be easily removed Note: Regular VpCI-609 has a tendency to clump. For dry fogging by using a low pressure air gun or by a water rinse. Typically, if applied application use VpCI-609S (with silica) where acceptable.
in aqueous form, the product does not require removal. If necessary, a simple water rinse or flush will suffice.
STANDARD TEST METHODS PACKAGING AND STORAGE NACE Standard TM0208-2008 Vapor Inhibiting Ability VpCI-609/609S powders are available in 5 pound (2.3 kg), 50 pound (23 NACE RP0487-2000 Selection of Rust Preventives kg), and 100 pound (45 kg) moisture barrier bags packed in fiber-lined OECD 306, BOD-28 Marine Biodegradability Test drums. Also available in pouches such as EcoPouch. Store in a sealed container in a dry warehouse and avoid direct exposure to sunlight with EPA/600/4-90/027F Sea Water Toxicity Test temperatures not exceeding 150°F (65°C). Under these conditions shelf MIL-I-22110C Vapor Inhibiting Ability life is up to 24 months.
FOR INDUSTRIAL USE ONLY KEEP OUT OF REACH OF CHILDREN KEEP CONTAINER TIGHTLY CLOSED NOT FOR INTERNAL CONSUMPTION CONSULT SAFETY DATA SHEET FOR MORE INFORMATION LIMITED WARRANTY All statements, technical information and recommendations contained herein are based on tests Cortec Corporation AND USER ASSUMES ALL RISK AND LIABILITY WHATSOEVER IN CONNECTION THEREWITH. No representation believes to be reliable, but the accuracy or completeness thereof is not guaranteed. or recommendation not contained herein shall have any force or effect unless in a written document signed by an officer of Cortec Corporation.
Cortec Corporation warrants Cortec products will be free from defects when shipped to customer. Cortec Corpora-tions obligation under this warranty shall be limited to replacement of product that proves to be defective. To obtain THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, EXPRESS, IMPLIED replacement product under this warranty, the customer must notify Cortec Corporation of the claimed defect within six OR STATUTORY, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY OR months after shipment of product to customer. All freight charges for replacement products shall be paid by customer. OF FITNESS FOR A PARTICULAR PURPOSE. IN NO CASE SHALL CORTEC CORPORATION BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Cortec Corporation shall have no liability for any injury, loss or damage arising out of the use of or the inability to use the products.
BEFORE USING, USER SHALL DETERMINE THE SUITABILITY OF THE PRODUCT FOR ITS INTENDED USE, Q
U Distributed by:
A EXCELLENCE I
T Y C O R P O R AT I O N Environmentally Safe VpCI /MCI Technologies 4119 White Bear Parkway, St. Paul, MN 55110 USA Phone (651) 429-1100, Fax (651) 429-1122 Toll Free (800) 4-CORTEC, E-mail info@cortecvci.com http://www.cortecvci.com Printed on recycled paper 100% post consumer Revised: 01/24/17. Supercedes: 01/06/16. ©Cortec Corporation 2002-2016 of Cortec Corporation.
All Rights Reserved. Copying of these materials in any form without the writted authorization of Cortec Corporation is strictly prohibited. 2016, ©Cortec Corp. ISO accreditation applies to Cortecs processes only.
Page 1/8 Safety data sheet according to 1907/2006/EC, Article 31 Printing date 30.03.2016 Revision: 30.03.2016
- SECTION 1: Identification of the substance/mixture and of the company/undertaking
- 1.1 Product identifier
- Trade name: VpCI-609
- 1.2 Relevant identified uses of the substance or mixture and uses advised against No further relevant information available.
- Application of the substance / the mixture Corrosion inhibitors
- 1.3 Details of the supplier of the safety data sheet
- Manufacturer/Supplier:
Cortec Corporation 4119 White Bear Parkway St. Paul, MN 55110 USA Phone (651) 429-1100 Fax (651) 429-1122
- Information department: regulatory@cortecvci.com
- 1.4 Emergency telephone number:
Spill, Leak, Fire, Exposure, or Accident 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> CHEMTREC contact:
USA and Canada 1-800-424-9300 International +1-703-527-3887 (collect calls accepted)
UK +(44)-870-8200418 SECTION 2: Hazards identification
- 2.1 Classification of the substance or mixture
- Classification according to Regulation (EC) No 1272/2008 GHS07 Skin Irrit. 2 H315 Causes skin irritation.
Eye Irrit. 2 H319 Causes serious eye irritation.
STOT SE 3 H335 May cause respiratory irritation.
- 2.2 Label elements
- Labelling according to Regulation (EC) No 1272/2008 The product is classified and labelled according to the CLP regulation.
- Hazard pictograms GHS07
- Signal word Warning
- Hazard-determining components of labelling:
proprietary ammonia derivate
- Hazard statements H315 Causes skin irritation.
H319 Causes serious eye irritation.
H335 May cause respiratory irritation.
- Precautionary statements P261 Avoid breathing dust/fume/gas/mist/vapours/spray.
(Contd. on page 2)
GB 42.0.9
Page 2/8 Safety data sheet according to 1907/2006/EC, Article 31 Printing date 30.03.2016 Revision: 30.03.2016 Trade name: VpCI-609 (Contd. of page 1)
P280 Wear protective gloves/protective clothing/eye protection/face protection.
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P321 Specific treatment (see on this label).
P405 Store locked up.
P501 Dispose of contents/container in accordance with local/regional/national/international regulations.
- 2.3 Other hazards WARNING! AS WITH ALL POWDERS, MAY FORM COMBUSTIBLE DUST CONCENTRATION IN AIR
- Results of PBT and vPvB assessment
- PBT: Not applicable.
- vPvB: Not applicable.
SECTION 3: Composition/information on ingredients
- 3.2 Chemical characterisation: Mixtures
Description:
Mixture of the substances listed below with nonhazardous additions.
- Ingredients:
proprietary ammonia derivate Skin Irrit. 2, H315; Eye Irrit. 2, H319; STOT SE 3, H335 50-100%
- Additional information The specific chemical identity and/or exact percentage (concentration) of composition has been withheld as a trade secret.
For the wording of the listed hazard phrases refer to section 16.
SECTION 4: First aid measures
- 4.1 Description of first aid measures
- After inhalation In case of unconsciousness place patient stably on side position for transportation.
- After skin contact Immediately wash with water and soap and rinse thoroughly.
- After eye contact Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
- After swallowing Do not induce vomiting; call for medical help immediately.
- 4.2 Most important symptoms and effects, both acute and delayed No further relevant information available.
- Information for doctor Show this safety data sheet to the doctor in attendance.
- 4.3 Indication of any immediate medical attention and special treatment needed No further relevant information available.
SECTION 5: Firefighting measures
- 5.1 Extinguishing media
- Suitable extinguishing agents CO2, extinguishing powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
- 5.2 Special hazards arising from the substance or mixture Carbon monoxide (CO)
Nitrogen oxides (NOx)
As with all dusts, fine particles suspended in air in critical proportions and in the presence of an ignition source may ignite and/or explode. Dust may be sensitive to ignition by electrostatic discharge, electrical arcs, sparks, welding torches, cigarettes, open flame, or other significant heat sources. As a precaution, implement standard safety measures for handling finely divided organic powders.
AIT (ASTM E2021): n/a °C (Contd. on page 3)
GB 42.0.9
Page 3/8 Safety data sheet according to 1907/2006/EC, Article 31 Printing date 30.03.2016 Revision: 30.03.2016 Trade name: VpCI-609 (Contd. of page 2)
- Additional information Explosion: Avoid generating dust; fine dust dispersed in air in sufficient concentrations, and in the presence of an ignition source is a potential dust explosion hazard.
SECTION 6: Accidental release measures
- 6.1 Personal precautions, protective equipment and emergency procedures Use respiratory protective device against the effects of fumes/dust/aerosol.
Wear protective equipment. Keep unprotected persons away.
Use extreme caution when dispersing dust in the air. Non-sparking tools/equipment should be used.
- 6.2 Environmental precautions: No special measures required.
- 6.3 Methods and material for containment and cleaning up: Ensure adequate ventilation.
- 6.4 Reference to other sections No dangerous substances are released.
See Section 7 for information on safe handling See Section 8 for information on personal protection equipment.
See Section 13 for disposal information.
SECTION 7: Handling and storage
- 7.1 Precautions for safe handling Ensure good ventilation/exhaustion at the workplace.
Prevent formation of dust.
- Information about protection against explosions and fires:
Keep ignition sources away - Do not smoke.
Protect against electrostatic charges.
Use explosion-proof apparatus / fittings and spark-proof tools.
Dust can combine with air to form an explosive mixture.
Wear shoes with conductive soles.
Minimize dust generation and accumulation.
Routine housekeeping should be instituted to ensure that dusts do not accumulate on surfaces.
Dry powders can build static electricity charges when subjected to the friction of transfer and mixing operations.
Provide adequate precautions, such as electrical grounding and bonding.
As a precaution to control dust explosion potential, implement safety measures to control ignition sources and dispersion of dusts. See NFPA standard 654, OSHA 29CFR1910.39 and others for more details.
- 7.2 Conditions for safe storage, including any incompatibilities
- Storage
- Requirements to be met by storerooms and receptacles: No special requirements.
- Information about storage in one common storage facility: Store away from foodstuffs.
- Further information about storage conditions: Keep receptacle tightly sealed.
- 7.3 Specific end use(s) No further relevant information available.
GB (Contd. on page 4) 42.0.9
Page 4/8 Safety data sheet according to 1907/2006/EC, Article 31 Printing date 30.03.2016 Revision: 30.03.2016 Trade name: VpCI-609 (Contd. of page 3)
SECTION 8: Exposure controls/personal protection
- Additional information about design of technical systems:
It is recommended that all dust control equipment such as local exhaust ventilation and material transport systems involved in handling of this product contain explosion relief vents or an explosion suppression system or an oxygen-deficient environment.
Ensure that dust-handling systems (such as exhaust ducts, dust collectors, vessels and processing equipment) are designed in a manner to prevent the escape of dust into the work area (i.e., there is no leakage from the equipment).
Use only appropriately classified electrical equipment and powered industrial trucks.
- 8.1 Control parameters WEL Long Term (8hr TWA) Inhalable dusts: 10mg/m3 WEL Long Term (8hr TWA) Respirable dusts: 5mg/m3
- Components with limit values that require monitoring at the workplace:
The product does not contain any relevant quantities of materials with critical values that have to be monitored at the workplace.
- Additional information: The lists that were valid during the creation were used as basis.
- 8.2 Exposure controls
- Personal protective equipment
- General protective and hygienic measures Keep away from foodstuffs, beverages and feed.
Immediately remove all soiled and contaminated clothing Wash hands before breaks and at the end of work.
Avoid contact with the eyes and skin.
- Breathing equipment:
For nuisance exposures use types P95 (US) or type P1 (EU EN 143) particle respirator. For higher level protection use type OV/AG/P99 (US) or type ABEK-P2 (EU EN 143) respirator cartridges. Use respirators and components tested and approved under appropriate governement standards such as NIOSH (US) or CEN (EU).
In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use respiratory protective device that is independent of circulating air.
- Protection of hands:
Protective gloves.
I.E., Nitrile, Viton, Neoprene The glove material has to be impermeable and resistant to the product/ the substance/ the preparation.
Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation
- Penetration time of glove material The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.
- Eye protection:
Wear appropriate protective eyeglasses or chemical safety goggles as described by OSHA's eye and face protection regulations in 29 CFR 1910.133 or European Standard EN166.
Tightly sealed goggles.
- Body protection: Protective work clothing.
GB (Contd. on page 5) 42.0.9
Page 5/8 Safety data sheet according to 1907/2006/EC, Article 31 Printing date 30.03.2016 Revision: 30.03.2016 Trade name: VpCI-609 (Contd. of page 4)
SECTION 9: Physical and chemical properties
- 9.1 Information on basic physical and chemical properties
- General Information
- Appearance:
Form: Powder Colour: Light beige
- Odour: Characteristic
- Odour threshold: Not determined.
- pH-value at 20 °C: 6-7 (1% aqueous)
- Change in condition Melting point/Melting range: 198 °C (*)
Boiling point/Boiling range: undetermined
- Flash point: Not applicable
- Flammability (solid, gaseous) Not determined.
- Ignition temperature:
Decomposition temperature: Not determined.
- Self igniting: Product is not selfigniting.
- Danger of explosion: As with all dusts, fine particles suspended in air in critical proprtions and in the presence of an ignition source may ignite and/or explode.
Dust may be sensitive to ignition by electrostatic discharge, electrical arcs, sparks, welding torches, cigarettes, open flame, or other significant heat sources. As a precaution, implement standard safety measures for handling finely divided organic powders.
Risk of explosion by shock, friction, fire or other sources of ignition.
- Explosion limits:
Lower: Not determined.
Upper: Not determined.
- Vapour pressure: Not applicable.
- Density: Not determined
- Relative density Not determined.
- Vapour density Not applicable.
- Evaporation rate Not applicable.
- Solubility in / Miscibility with Water at 20 °C: 200 g/l (*)
- Partition coefficient (n-octanol/water): Not determined.
- Viscosity:
dynamic: Not applicable.
kinematic: Not applicable.
- 9.2 Other information The above data are typical values and do not constitute a specification.
- Properties have been calculated.
SECTION 10: Stability and reactivity
- 10.1 Reactivity No further relevant information available.
(Contd. on page 6)
GB 42.0.9
Page 6/8 Safety data sheet according to 1907/2006/EC, Article 31 Printing date 30.03.2016 Revision: 30.03.2016 Trade name: VpCI-609 (Contd. of page 5)
- 10.2 Chemical stability
- Thermal decomposition / conditions to be avoided: No decomposition if used according to specifications.
- 10.3 Possibility of hazardous reactions No dangerous reactions known
- 10.4 Conditions to avoid No further relevant information available.
- 10.5 Incompatible materials: Strong oxidizing agents; alkalis/bases
- 10.6 Hazardous decomposition products: Ammonia, in wet conditions SECTION 11: Toxicological information
- 11.1 Information on toxicological effects
- Acute toxicity Based on available data, the classification criteria are not met.
- LD/LC50 values that are relevant for classification: LD50 5,000 mg oral Rat
- Primary irritant effect:
- Skin corrosion/irritation Causes skin irritation.
- Serious eye damage/irritation Causes serious eye irritation.
- Respiratory or skin sensitisation Based on available data, the classification criteria are not met.
- CMR effects (carcinogenity, mutagenicity and toxicity for reproduction)
- Germ cell mutagenicity Based on available data, the classification criteria are not met.
- Carcinogenicity Based on available data, the classification criteria are not met.
- Reproductive toxicity Based on available data, the classification criteria are not met.
- STOT-single exposure May cause respiratory irritation.
- STOT-repeated exposure Based on available data, the classification criteria are not met.
- Aspiration hazard Based on available data, the classification criteria are not met.
- SECTION 12: Ecological information
- 12.1 Toxicity
- Aquatic toxicity:
LC50/ 48 h 251 mg/l (Daphnia pulex (water flea)) (48 Hours) 316 mg/l (Pimphales promelas) (48 Hours) 138.9 mg/l (Scophthalmus maximus - Turbot) (48 Hours)
LOEC 1000 mg/l (Daphnia pulex (water flea)) (LOEC) 300 mg/l (M. beryllina (Inland Silverside)) (LOEC) 600 mg/l (Mysidopsis bahia) (LOEC) 1000 mg/l (Pimphales promelas) (LOEC)
- 12.2 Persistence and degradability biodegradable
- 12.3 Bioaccumulative potential No further relevant information available.
- 12.4 Mobility in soil No further relevant information available.
- Additional ecological information:
- General notes: Generally not hazardous for water.
- 12.5 Results of PBT and vPvB assessment
- PBT: Not applicable.
- vPvB: Not applicable.
- 12.6 Other adverse effects No further relevant information available.
GB (Contd. on page 7) 42.0.9
Page 7/8 Safety data sheet according to 1907/2006/EC, Article 31 Printing date 30.03.2016 Revision: 30.03.2016 Trade name: VpCI-609 (Contd. of page 6)
SECTION 13: Disposal considerations
- 13.1 Waste treatment methods
- Recommendation Must not be disposed of together with household garbage. Do not allow product to reach sewage system.
- European waste catalogue The European Waste Catalogue (EWC) waste codes do not refer to product but to origin. The manufacturer is therefore unable to quote a waste code for products which are used in various industries. Any codes shown should be regarded as a recommendation to the user.
07 00 00 WASTES FROM ORGANIC CHEMICAL PROCESSES 07 01 00 wastes from the manufacture, formulation, supply and use (MFSU) of basic organic chemicals 07 01 99 wastes not otherwise specified HP 4 Irritant - skin irritation and eye damage HP 5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity
- Uncleaned packagings:
- Recommendation: Disposal must be made according to official regulations.
- Recommended cleansing agent: Water, if necessary with cleansing agents.
SECTION 14: Transport information
- 14.1 UN-Number
- ADR, ADN, IMDG, IATA Void
- 14.2 UN proper shipping name
- ADR, ADN, IMDG, IATA Void
- 14.3 Transport hazard class(es)
- ADR, ADN, IMDG, IATA
- Class Void
- 14.4 Packing group
- ADR, IMDG, IATA Void
- 14.5 Environmental hazards:
- Marine pollutant: No
- 14.6 Special precautions for user Not applicable.
- 14.7 Transport in bulk according to Annex II of Marpol and the IBC Code Not applicable.
- UN "Model Regulation": Void GB (Contd. on page 8) 42.0.9
Page 8/8 Safety data sheet according to 1907/2006/EC, Article 31 Printing date 30.03.2016 Revision: 30.03.2016 Trade name: VpCI-609 (Contd. of page 7)
SECTION 15: Regulatory information
- 15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture
- Directive 2012/18/EU
- Named dangerous substances - ANNEX I None of the ingredients is listed.
- National regulations
- Water hazard class: Generally not hazardous for water.
- 15.2 Chemical safety assessment: A Chemical Safety Assessment has not been carried out.
SECTION 16: Other information This information is based on our present knowledge. However, this shall not constitute a guarantee for any specific product features and shall not establish a legally valid contractual relationship.
Cortec Corporation does not warranty any translation of this SDS not created by Cortec Corporation.
Refer to NFPA 654, Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids, for safe handling.
- Relevant phrases H315 Causes skin irritation.
H319 Causes serious eye irritation.
H335 May cause respiratory irritation.
- Abbreviations and acronyms:
ICAO: International Civil Aviation Organisation RID: Rglement international concernant le transport des marchandises dangereuses par chemin de fer (Regulations Concerning the International Transport of Dangerous Goods by Rail)
ADR: Accord européen sur le transport des marchandises dangereuses par Route (European Agreement concerning the International Carriage of Dangerous Goods by Road)
IMDG: International Maritime Code for Dangerous Goods IATA: International Air Transport Association GHS: Globally Harmonised System of Classification and Labelling of Chemicals EINECS: European Inventory of Existing Commercial Chemical Substances ELINCS: European List of Notified Chemical Substances CAS: Chemical Abstracts Service (division of the American Chemical Society)
LC50: Lethal concentration, 50 percent LD50: Lethal dose, 50 percent PBT: Persistent, Bioaccumulative and Toxic vPvB: very Persistent and very Bioaccumulative Skin Irrit. 2: Skin corrosion/irritation, Hazard Category 2 Eye Irrit. 2: Serious eye damage/eye irritation, Hazard Category 2 STOT SE 3: Specific target organ toxicity - Single exposure, Hazard Category 3
- Data compared to the previous version altered.
GB 42.0.9
Reducing Heat Exchanger Fouling and Metallic Corrosion with Vapor Infusion Technologies Michael Radicone, Specialty Products Lead, HTRI
Numerous studies indicate there are benefits of using aeration within a heat exchange device; Enhancement of heat transfer due Heat Transfer Enhancement Caused by Sliding Bubbles.
to bubbles passing through a Bayazit Vapor and gas bubbles are known to increase heat transfer rates from narrow vertical rectangular adjacent heated surfaces, a phenomenon attributed to the interaction channel. between the bubble and the thermal boundary layer.
Monde, M Dynamic Flow Structures in the Wakes of Thermal performance improvement by Sliding Bubbles for Convective Heat Transfer injecting air into water flow Enhancement Shyy WoeiChang Bo-JyunHuang Donnelly, Persoons, Murray Heat transfer enhancement due to air Effects of bubble size on heat transfer enhancement by bubble injection into a horizontal double sub-millimeter bubbles for laminar natural convection pipe heat exchanger. along a vertical plate.
Hamed_Sadighi_Dizaji Kitagawa, Uchida, Hagiwara Decreasing the Scale Fouling of Heat Exchanger Plates Using Air Bubbles.
Baek, Seol, Lee, Yoon Unfortunately, aeration of cooling water can introduce dissolved oxygen through 2 mass transfer inducing corrosion or accelerated biofouling
Vapor Infusion Technology allows for Aeration with reduced oxidation while providing BVT (Bubble Vapor Treatment).
Vapor infusion is a patented process that safely generates SCRUBBING, transitory bubbles to reduce the formation of foulants on heat exchanger surfaces while imparting targeted and reduced chemical treatments.
When using iodine vapor, the bubbles are denser, heavier and less soluble than air bubbles.
8 times denser Vapor generation Bubble perfusion 3 times less soluble These bubbles have a low oxygen and chemical treatment vapor core and an aqueous reactive surface that;
- present a reduced treatment volume
- works during function; CIP, Teardown, Sponge ball
- inhibits corrosion
- pulsed, air/fluid proportioning
- mechanically disrupts foul formation
- adaptable to any environment
- Uses only grams per application
- reduces sedimentary action 3
ESTCP study compared two similar heat exchangers onboard a working Navy test ship. One received infusion at 3 minutes every half hour and was compared to a non-infused control. There was no release of metal or non metallic ions during infusion and a complete inhibition of bio-fouling.
Success criteria Actual outcome A 50% increase between acid cleanings from 60 days to 90 days. 270 days* End of study.
Less than 200 ppb increase in iodine in effluent. Only 35 ppb increase.
Low increase in metallic ions during infusion. No increase.
- No difference in temperature and pressure before and after a final acid wash**, indicating zero biofouling.
- Reduction in cleaning time by 50% and hazardous waste generated.
- Infusion duration was only 3 minutes per half hour, and total monthly cartridge iodine loss was less than 20 grams.
- The infused exchanger was used 85% of time and still exhibited no bio-fouling.
Dynamic bubble sparging with reduced oxygen presence Minerals and Mud and BVT Minerals and Mud Metals Metals Macro fouling agents Macro fouling agents in the device fluid on the device surfaces BVT provides for both the gaseous and aqueous presentation of the treatment chemical on the bubble surface.
Gas solubility provides for the presentation of the chemical treatment into the fluid surrounding the bubble.
Vaporous treatment
Research performed at WSU and Cornell proves the effectiveness of bubble surface vapor transfer and its potential for reduced residue.
The results of one 90 second infusion results in a complete reduction. Disinfection occurs rapidly.
Time (sec) cfu/ml control 7,200,000 15 tntc 30 tntc 60 0 90 0 120 0 Minimal residue.
After a 90 second infusion there was less than 50 ppb residue in the fluid volume.
Ship hull hard foul prevention; iodinated air and control-3 year study Naval Undersea Warfare Center Division and Florida Institute of Technology Early observations indicate an inhibitory effect on the growth cycle of some fouling species, as well as on the surface bonding capabilities of barnacles. Water sampling analysis indicated no change in sea water iodine levels during full iodine infusion compared to ambient sea water.
7
ESTCP study compared two similar heat exchangers onboard a working Navy test ship. One received infusion at 3 minutes every half hour and was compared to a non-infused control. There was no release of metal or non metallic ions during infusion and a complete inhibition of bio-fouling.
Success criteria Actual outcome A 50% increase between acid cleanings from 60 days to 90 days. 270 days* End of study.
Less than 200 ppb increase in iodine in effluent. Only 35 ppb increase.
Low increase in metallic ions during infusion. No increase.
- No difference in temperature and pressure before and after a final acid wash**, indicating zero biofouling.
- Reduction in cleaning time by 50% and hazardous waste generated.
- Infusion duration was only 3 minutes per half hour, and total monthly cartridge iodine loss was less than 20 grams.
- The infused exchanger was used 85% of time and still exhibited no bio-fouling.
Fouled Engine cooler NCL Sun after 14 month infusion 9
Fouled Engine cooler NCL Sky after 14 month infusion 10
Vaporous treatments:
- Benzoate salts Ferrous and aluminum corrosion inhibition Macro foul disruption Oxygen scavenging Void and containment corrosion inhibition
- Benzotriazole Ferrous and cupreous corrosion inhibition Macro foul disruption Void and containment corrosion inhibition Oxygen scavenging
- Iodine Vapor
- Bio-organic catalyst 11
Injection manifolds 2 vapor, 1 control Infusion points, bubble dispersant, pressure gauge, flow meters, flow valves Skids 1-inch X 3/4 1-inch X 3/4 compression compression Light hindering Discharge 3/4 HX tube /warming tarp manifold with sampling points Copper VCI Control Iodine Infusion Compressor with air device, dryer/drain, desiccant, provided infusion device.
by HTRI Two oil less compressors in tandem Water pump with coarse strainer Flow control valve Water to canal Water from canal Enclosure Water to canal 12
NCL cruise ship sea chest and seawater systems.
Pulsed Iodine Ultra-fine* microbubbles with or without Aqua Cat post pumps.
- Idec Ultrafine Bubbles 13
ENCLOSURE 2 TO L-2019-204
Ron Desantis FLORIDA DEPARTMENT OF Governor Environmental Protection Jeanette Nuiiez Lt. Governor Bob Martinez Center Noah Valenstein 2600 Blair Stone Road Secretary Tallahassee, FL 32399-2400 November 20, 2019 SENT BY EMAIL TO:
(meghna.pandya@fpl .com)
Ms. Meghna Pandya Environmental Specialist Florida Power & Light Company (FPL) 700 Universe Blvd. (GTNJB)
Juno Beach, Florida 33408 Re: Florida Power & Light Company Turkey Point Power Plant NPDES Permit No. FL0001562 90-Day Trial Approval
Dear Ms. Pandya:
The Florida Department of Environmental Protection (Department) has received your request via email dated November 4, 2019 requesting authorization for a 90 day trial use of vapor infusion technologies to reduce heat exchanger fouling and cmrnsion for treatment of Units 3 and 4. The Department has determined that this activity would qualify as a minor modification to the operation of the Turkey Point Power Plant pursuant to Rule 62-620.200(24), Florida Administrative Code (F.A.C.), and can be authorized by a permit revision pursuant to Rule 62-620.325(2), F.A.C. This letter authorizes a trial period for 90 days beginning upon initial treatment.
Please provide three copies, or an electronic copy, of the testing results to the Wastewater Management Program in Tallahassee (epost.bwfriw@dep.state.fl.us). If you have any questions, please contact Frank Wall or me at (850)245-8589.
Sincerely, 1YV};l/}.C.(./VV.-<'.J Marc H. Harris, P .E.
Program Administrator Wastewater Management Program Division of Water Resource Management MH/fw Attachment cc: Kent Edwards, FDEP West Palm Beach (kent.edwards@dep.state.fl .us)
Nancy Ross, FDEP Tallahassee (nancy.ross@floridadep.gov) 111ww. dep.state.fl.us