TURKEY POINT UNIT 3 2004 REFUELING OUTAGE
SUMMARY
OF INSERVICE INSPECTION EXAMINATIONS I
DATE: 02/15/OS TURKEY POINT THIRD INTERVAL [TP31 - UNIT 3 PAGE: 1 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 3, PERIOD 3, OUTAGE 3 (04)
CLASS 1 C COMPONENTS REACTOR PRESSURE VESSEL 3-001 ASME STATUS N I 0 SEC. XI 0 N G T R S E H
SUMMARY
EXAMINATION AREA CATEGY EMAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METV[OD DATA SHEET # C G M R **CALIBRATION BLOCK" (REF. DWG. NO. 5613-M-4000) 000100 3-WR-18 B-A C UT 2004-TP3-010 - - - - 10/19/2004 to 10/23/2004 -
FLANGE TO UPPER SHELL B1.30 54-5054158-00 X - - - UT Complete. No Recordable 2L2.25CZR TOP FLANGE X Indications. Total of 71%
7L2.25CIR TOP FLANGE 12L2.25CIR TOP FLANGE - - X _ CRV was achieved when scanning from the top of the flange and from the vessel.
Limitations noted were the keyways and irradiation slots.
10/31/2004 - UT complete.
Geometric Indication from monitor taps at 47 deg. and 137 deg. Also, signal received from radius at 31.2k depth with the 7 deg.
and 12 deg. transducers.
Manual scanned from top of flange.
- UT-314**
000200 3-WR-33 B-A C UT 54-5054158-00 X - - - 10/19/2004 to 10/23/2004 -
UPPER SHELL TO B1.11 UT Complete. No Recordable INTERMEDIATE SHELL Indications. 100% CRV Achieved. **UT-1**
000300 3-WR-10 B-A C UT 54-5054158-00 X - - - 10/19/2004 to 10/23/2004 -
INTERMEDIATE SHELL TO 31.11 UT Complete. No Recordable LOWER SHELL Indications. 100% CRV Achieved. **UT-1**
DATE: 02/1S/05 TURKEY POINT THIRD INTERVAL [TP3] - UNIT 3 PAGE: 2 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 3, PERIOD 3, OUTAGE 3 (04)
CLASS 1 C COMPONENTS REACTOR PRESSURE VESSEL 3-001 ASME -~.STATUS N I 0 SEC. XI 0 N G T
SUMMARY
EXAMINATION AREA CATEGY EXAM ER SI E 0 H E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK*"
(REF. DWG. NO. 5613-M-4000) 000400 3-WR-31 B-A C UT 54-5054158-00 X - - - 10/19/2004 to 10/23/2004 -
LOWER SHELL TO LOWER B1.11 UT Complete. No Recordable HEAD RING Indications. 90% CRV Achieved. **UT-1**
000500 3-WR-9 B-A C UT 54-5054158-00 X - - - 10/19/2004 to 10/23/2004 -
LOWER HEAD RING TO B1.21 UT Complete. No Recordable BOTTOM HEAD Indications. 83% CRV Achieved. Limited scan due to incores **UT.-1, UT-3**
000600 3-DI-A B-D C UT 54-5054158-00 - - - X 10/19/2004 to 10/23/2004 -
INLET NOZZLE TO SHELL B3.90 UT Complete. Acceptable 6 80 DEG. Recordable Indications.
Fourteen subsurface indications were observed due to fabrication anomolies. 95% CRV Achieved. Limited due to nozzle boss. **UT-1, UT-1S, UT-32**
000700 3-DO-A B-D C UT 54-5054158-00 X - - - 10/19/2004 to 10/23/2004 -
OUTLET NOZZLE TO SHELL B3.90 UT Complete. No Recordable
- 130 DEG. Indications. 90% CRV Achieved. Limited due to nozzle boss. **UT-1, UT-15, UT-32**
DATE: 02/15/05 TURKEY POINT THIRD INTERVAL ETP3J - UNIT 3 PAGE: 3 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 3, PERIOD 3, OUTAGE 3 (04)
CLASS 1 C COMPONENTS REACTOR PRESSURE VESSEL 3-001 ASME STATUS N I 0 SEC. XiI ON G T
SUMMARY
EXAMINATION AREA CATEGY EXAM E I 0 H REMARKS NUMBER IDENTIFICATION ITEM NO l METHOD DATA SHEET # C G M R *"CALIBRATION BLOCK**
(REF. DWG. NO. 5613-M-4000) 000800 3-Dr-C B-D C UT 54-5054158-00 - - - X 10/19/2004 to 10/23/2004 -
INLET NOZZLE TO SHELL B3.90 UT Complete. Acceptable
@ 200 DEG. Recordable Indications. Six subsurface indications were observed due to fabrication anomalies. 95% CRV Achieved. Limited due to nozzle boss. **UT-1, UT-15, UT-32**
000900 3-DO-C B-D C UT 54-5054158-00 - - - X 10/19/2004 to 10/23/2004 -
OUTLET NOZZLE TO SHELL B3.90 UT Complete. Acceptable
- 250 DEG. Recordable Indications.
Three subsurface indications were observed due to fabrication anomalies. 90%
CRV Achieved. Limited due to nozzle boss. **UT-1, UT-15, UT-32**
001000 3-DI-B B-D C UT 54-5054158-00 - - - X 10/19/2004 to 10/23/2004 -
INLET NOZZLE TO SHELL B3.90 UT Complete. Acceptable a 320 DEG. Recordable Indications. One subsurface indications was observed due to fabrication anomoly. 95% CRV Achieved.
Limited due to nozzle boss.
- UT-1, UT-15, UT-32**
001100 3-DO-B B-D C UT 54-5054158-00 - - - - 10/19/2004 to 10/23/2004 -
OUTLET NOZZLE TO SHELL B3.90 UT Complete. No Recordable 0 10 DEG. Indications. 90% CRV Achieved. Limitation due to nozzle boss. **UT-1, UT-15, UT-32**
DATEt 02/15/05 TURKEY POINT THIRD INTERVAL [TP3] - UNIT 3 PAGE: 4 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 3, PERIOD 3, OUTAGE 3 (04)
CLASS 1 C COMPONENTS REACTOR PRESSURE VESSEL 3-001 ASME TATUS N I 0 SEC. XII 0 N G T
SUMMARY
EXAMINATION AREA CATEGY EXAM ER SI E 0E H REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-M-4000) 001150 3-DO-B-SUPPORT-5 P-A C VT-3 4.3-009 - X - - 9/28/2004 - VT-3 complete.
OUTLET NOZZLE TO SHELL 11.40 Light rust and light boric C 10 DEG. acid observed on support.
No damage observed.
001200 3-DI-A-IRS B-D C ENEANCEDVT 2004-EOC20-01 X - - - 10/23/2004 - Enhanced Visual INLET NOZZLE INNER B3.200 Complete. No Recordable RADIUS Indications. Framatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00. **UT-32**
001300 3-DO-A-IRS B-D C ENHANCEDVT 2004-EOC20-01 X - - - 10/23/2004 - Enhanced Visual OUTLET NOZZLE INNER B3.100 Complete. No Recordable RADIUS Indications. Framatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00. **UT-32**
001400 3-DI-C-IRS B-D C ENHANCEDVT 2004-EOC20-01 X - - - 10/23/2004 - Enhanced Visual INLET NOZZLE INNER B3.100 Complete. No Recordable RADIUS Indications. Framatome'a parent cocument for the Reactor Pressure Vessel 10-year examination is 54-5054158-00. **UT-32**
DATE: 02/15/05 TURKEY POINT THIRD INTERVAL [TP3] - UNIT 3 PAGE: 5 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 3, PERIOD 3, OUTAGE 3 (04)
CLASS 1 C COMPONENTS REACTOR PRESSURE VESSEL 3-001 ASME SEC. XI KTATUS N O
I N G 0
T R S E H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I C E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK"
.5-(REF. DWG. NO. 5613-M-4000) 001500 3-DO-C-IRS B-D C ENHANCEDVT 2004-EOC20-01 X - - - 10/23/2004 - Enhanced Visual OUTLET NOZZLE INNER B3.100 Complete. No Recordable RADIUS Indications. Framatome'B parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00. **UT-32**
001600 3-DI-B-IRS B-D C ENHANCEDVT 2004-EOC20-01 X - - - 10/23/2004 - Enhanced Visual INLET NOZZLE INNER B3.100 Complete. No Recordable RADIUS Indications. Framatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00. **UT-32**
001700 3-DO-B-IRS B-D C ENHANCEDVT 2004-EOC20-01 X - - - 10/23/2004 - Enhanced Visual OUTLET NOZZLE INNER B3.100 Complete. No Recordable RADIUS Indications. Framatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00. **UT-32**
001950 CORE SUPPORT BARREL B-N-3 C VT-3 2004 EOC20-05 X - - - 10/20/2004 - VT-3 Complete.
INLET PLOW IMPINGEMENT B13.70 No Recordable Indications.
AREAS Pramatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-S054158-00.
DATE: 02/15/05 TURREY POINT THIRD INTERVAL [TP33 - UNIT 3 PAGE: 6 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 3, PERIOD 3, OUTAGE 3 (04)
CLASS 1 C COMPONENTS REACTOR PRESSURE VESSEL 3-001 ASME _STATUS NI 0 SEC. XI ON 0 T R S E H REMARKS
SUMMARY
EXAMINATION AREA CATEGY FM IM EI 0 E NUMBER IDENTIFICATION ITEM NO METS 10CD DATA SHEET # C G M R *"CALIBRATION BLOCK**
(REF. DWG. NO. 5613-M-4000) 002000 CORE SUPPORT BARREL B-N-3 C VT-3 2004-EOC20-05 X - - - 10/21/2004 - VT-3 Complete.
OUTLET NOZZLES B13.70 No Recordable Indications.
INTERIOR SURFACES Framatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
002050 CORE SUPPORT BARREL B-N-3 C VT-3 2004-EOC20-05 X - - - 10/20/2004 - VS-3 Complete.
OUTLET NOZZLES B13.70 No Recordable Indications.
EXTERIOR SURFACES Framatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
002100 CORE SUPPORT BARREL B-N-3 C VT-3 2004-EOC20-05 X - - - 10/20/2004 - VT-3 Complete.
UPPER SECTION EXTERIOR B13.70 No Recordable Indications.
SURFACES Framatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
002150 CORE SUPPORT BARREL B-N-3 C VT-3 2004-EOC20-05 X - - - 10/21/2004 - VT-3 Complete.
UPPER SECTION INTERIOR B13.70 No Recordable Indications.
SURFACES Framatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
DATE: 02/15/05 TURKEY POINT THIRD INTERVAL ITP31 - UNIT 3 PAGE: 7 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 3, PERIOD 3, OUTAGE 3 (04)
CLASS 1 C COMPONENTS REACTOR PRESSURE VESSEL 3-001 ASME -STATUS N I 0 SEC. XI ON G T R SE H
SUMMARY
EXAMINATION AREA CATEGY EXAM REMARKS E I0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C GM R **CALIBRATION BLOCK'*
(REF. DWG. NO. 5613-M-4000) 002200 CORE SUPPORT BARREL B-N-3 C VT-3 2004-EOC20-05 X - - - 10/19/2004 - VT-3 Complete.
LOWER SECTION EXTERIOR B13.70 No Recordable Indications.
SURFACES Framatome's parent document for the Reactor Pressure Vessel 10-year examination in 54-5054158-00.
003100 REACTOR VESSEL B-N-1 C VT-3 2004-EOC20-01 X - - - 10/25/2004 - VT-3 Complete.
WELDS AND INTERIOR B13.10 No Recordable Indications.
SURFACES Framatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
____________REF_____N._-V______________________________________________________________________
(REP. DWG. NO. 3-V0l) 003900 CORE SUPPORT BARREL B-N-3 C VT-3 2004-EOC20-07 X - - - 10/19/2004 - VT-3 Complete.
SUPPORT B13.70 No Recordable Indications.
COLUMNS(INSTRUMENTATIO Framatome's parent document N) for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
004300 REACTOR VESSEL TO HEAD B-N-1 C VT-3 2004-EOC20-02 X - - - 10/25/2004 - VT-3 Complete.
UPPER SUPPORT PLATE B13.10 No Recordable Indications.
KEYWAYS Framatome'e parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
DATE: 02/15/OS TURKEY POINT THIRD INTERVAL [TP3] - UNIT 3 PAGE: 8 REVISION: INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 3, PERIOD 3, OUTAGE 3 (04)
CLASS 1 C COMPONENTS REACTOR PRESSURE VESSEL 3-001 ASME rSTATUS N I 0 SEC. XI 0 N TS R S Ez REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I O E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C a M R **CALIBRATION BLOCK" (REF. DWG. NO. 3-V01) 004700 CORE SUPPORT BARREL B-N-3 C VT-3 2004-EOC20-07 X - - - 10/19/2004 - VT-3 Complete.
DIFFUSER PLATE (FLOW B13.70 No Recordable Indications.
MIXER DEVICES) Pramatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
005500 CRUCIFORM INSTR. GUIDE B-N-3 C VT-3 2004-EOC20-07 X - - - 10/19/2004 - VT-3 Complete.
GUIDE TUBES AND B13.70 No Recordable Indications.
FASTENERS Framatome'B parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
006300 SECONDARY CORE SUPPORT B-N-3 C VT-3 2004-EOC20-07 X - - - 10/19/2004 - VT-3 Complete.
ALIGNMENT XEYWAYS AND B13.70 No Recordable Indications.
FASTENERS Framatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
006800 SECONDARY CORE SUPPORT B-N-3 C VT-3 2004-EOC20-07 X - - - 10/25/2004 - VT-3 Complete.
BASE PLATE AND B13.70 No Recordable Indications.
STRUCTURE Framatome's parent document for the Reactor Pressure Vessel 10-year examination is S4-50541SB-00.
DATE: 02/15/05 TURKEY POINT THIRD INTERVAL [TP3] - UNIT 3 PAGE: 9 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 3, PERIOD 3, OUTAGE 3 (04)
CLASS 1 C COMPONENTS REACTOR PRESSURE VESSEL 3-001 ASME _STATUS N I 0 SEC. XI 0 N G T R S E H
SUMMARY
EXAMINATION AREA CATEGY EXAM E I O E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 3-V01) 006810 SECONDARY CORE SUPPORT B-N-3 C VT-3 2004-EOC20-07 X - - - 10/19/2004 - VT-3 Complete.
TIE PLATES B13.70 No Recordable Indications.
Framatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
007200 CORE SUPPORT BARREL B-N-3 C VT-3 2004-EOC20-06 X - - - 10/20/2004 - VT-3 Complete.
BY-PASS FLOW NOZZLES B13.70 No Recordable Indications.
Pramatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
007600 CORE SUPPORT BARREL B-N-3 C VT-3 2004-EOC20-06 X - - - 10/20/2004 - VT-3 Complete.
VESSEL TO HEAD B13.70 No Recordable Indications.
ALIGNMENT PINS Pramatoms's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
009200 BAFFLE BOLTS AND B-N-3 C VT-3 2004-EOC20-05 X - - - 10/21/2004 - VT-3 Complete.
DEVICES IN TOP THREE B13.70 No Recordable Indications.
ROWS OF FORMERS Framatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
DATE: 02/15/05 TURKEY POINT THIRD INTERVAL [TP3] - UNIT 3 PAGE: 10 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 3, PERIOD 3, OUTAGE 3 (04)
CLASS 1 C COMPONENTS REACTOR PRESSURE VESSEL 3-001 ASME _SSASUS N I 0 SEC. xI ON G T R SE H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R *CALIBRATION BLOCK**
(REF. DWG. NO. 3-V01) 009210 CORE SUPPORT BARREL B-N-3 C VT-3 2004-EOC20-05 X - - - 10/21/2004 - VT-3 Complete.
BAFFLE PLATES B13.70 No Recordable Indications.
Framatome's parent document for the Reactor Pressure Vessel 10-year examination in 54-5054158-00.
009220 CORE SUPPORT BARREL B-N-3 C VT-3 2004-EOC20-05 X - - - 10/21/2004 - VT-3 Complete.
TOP FORMER PLATE B13.70 No Recordable Indications.
Framatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-SOS4158-00.
009600 LOWER CORE PLATE B-N-3 C VT-3 2004-EOC20-07 X - - - 10/19/2004 - VT-3 Complete.
PLATE, COLUMN B13.70 No Recordable Indications.
BOLTING,GUIDE TUBE Fra-atome's parent document BOLTING for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
009610 CORE SUPPORT BARREL B-N-3 C VT-3 2004-EOC20-07 X - - - 10/19/2004 - VT-3 Complete.
ACCESSIBLE UNDERSIDE B13.70 No Recordable indications.
OF LOWER CORE PLATE Framatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
DATE: 02/15/05 TURKEY POINT THIRD INTERVAL ITP31 - UNIT 3 PAGE: 11 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 3, PERIOD 3, OUTAGE 3 (04)
CLASS 1 C COMPONENTS REACTOR PRESSURE VESSEL 3-001 ASME SEC. XI FSTATUS N ON I 0 TG R SE H
SUMMARY
EXAMINATION AREA CATEGY EXAM E I0 E REMARKS NUMBER IDENTIFICATION ITEM NO .METHOD DATA SHEET # C OM R **CALIBRATION BLOCK" (REF. DWG. NO. 3-V01) 010900 CORE SUPPORT BARREL B-N-3 C VT-3 2004-EOC20-06 X 10/20/2004 - VT-3 Complete.
SUPPORT FLANGE, B13 .70 Recordable Indication on SEATING SURFACES, Irradiation Plug at 40 PLUGS degrees. Irradiation plug was compressed/crushed and bent. The outer edge was also deformed in the access hole. Reference CR 2004-11474. Engineering Disposition: Use as-is.
The capsule is tight in place and performing its core bypass function and minimal contact damage with the corresponding surface of the reactor vessel. A final evaluation was completed by Westinghouse. The corresponding area on the upper internals was also examined with no recordable indications. Framatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
010950 CORE SUPPORT BARREL B-N-3 C VT-3 2004-EOC20-06 X - - - 10/20/2004 - VT-3 Complete.
HOLD DOWN SPRING B13.70 No Recordable Indications.
Framatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
DATE: 02/15/05 TURKEY POINT THIRD INTERVAL ETP31 - UNIT 3 PAGE: 12 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 3, PERIOD 3, OUTAGE 3 (04)
CLASS 1 C COMPONENTS REACTOR PRESSURE VESSEL 3-001 ASME _STATUS N I 0 SEC. XI O N G R S E H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I 0 NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET N C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 3-V01) 011000 IRRADIATION SPECIMEN B-N-3 C VT-3 2004-EOC20-04 X - - - 10/19/2004 AND 10/20/2004 -
CAPSULES AND B13.70 VT-3 Complete. No ATTACHMENT WELDS Recordable Indications.
Framatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
011800 CORE SUPPORT BARREL B-N-3 C VT-3 2004-EOC20-04 X - - - 10/19/2004 - VT-3 Complete.
OUTLET NOZZLE TO B13.70 No Recordable Indications.
VESSEL SEATING SURFACE Framatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
012200 CORE SUPPORT BARREL B-N-3 C VT-3 2004-EOC20-07 X - - - 10/19/2004 - VT-3 Complete.
RADIAL SUPPORT KEYS B13.70 No Recordable Indications.
Framatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
013000 CORE SUPPORT BARREL B-N-3 C VT-3 2004-EOC20-04 X - - - 10/20/2004 - VT-3 Complete.
THERMAL SHIELD & B13.70 No Recordable Indications.
ATTACHMENTS AT BOTTOM Framatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
DATE: 02/15/05 TURKEY POINT THIRD INTERVAL [TP3] - UNIT 3 PAGE: 13 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 3, PERIOD 3, OUTAGE 3 (04)
CLASS 1 C COMPONENTS REACTOR PRESSURE VESSEL 3-001 ASME TATUS N I 0 SEC. xiI ON G T
SUMMARY
EXAMINATION AREA CATEGY I EXAM E I a H REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET I C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 3-V01) 013005 CORE SUPPORT BARREL B-N-3 C VT-3 2004-EOC20-04 X - - - 10/20/2004 - VT-3 Complete.
UPPER THERMAL SHIELD B13.70 No Recordable Indications.
BOLTING/PINS Framatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
013010 CORE SUPPORT BARREL B-N-3 C VT-3 2004-EOC20-04 X - - - 10/20/2004 - VT-3 Complete.
LOWER THERMAL SHIELD B13.70 No Recordable Indications.
BOLTING/PINS Framatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
013020 REACTOR VESSEL B-N-2 C VT-3 2004-EOC20-02 - - - X 10/23/2004 - VT-3 Complete.
RADIAL SUPPORT KEYWAYS B13.60 Recordable Indications identified on Radial Support Keyway at 270 degrees.
Several scratches and small gouges were observed on the I.D. edge of the mating surfaces. Reference CR 2004-11911. Engineering Dispositions The tool marks do not affect internals of the reactor vessel radial support from performing its intended function, therefore this condition is not a non-conformance. The condition is acceptable.
Framatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
DATE: 02/15/05 TURXEY POINT THIRD INTERVAL ETP3] - UNIT 3 PAGE: 14 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 3, PERIOD 3, OUTAGE 3 (04)
CLASS 1 C COMPONENTS REACTOR PRESSURE VESSEL 3-001 ASME TATUS N I 0 SEC. XI O N G T
SUMMARY
EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 3-V01) 013050 VESSEL INSTRUMENTATION B-N-1 C VT-3 2004-EOC20-02 X - - - 10/20/2004 - VT-3 Complete.
LOWER HEAD & B13.10 No Recordable Indications.
INSTRUMENT GUIDE TUBES Framatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
013060 OUTLET NOZZLE TO B-N-1 C VT-3 2004-EOC20-01 X - - - 10/23/2004 and 10/25/2004 -
INNER RADIUS SEALING B13.10 VT-3 Complete. No SURFACE Recordable Indications.
Framatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
013065 VESSEL OUTLET NOZZLES B-N-l C VT-3 2004-EOC20-01 X - - - 10/23/2004 and 10/25/2004 -
INTERIOR SURFACES B13.10 VT-3 Complete. No Recordable Indications.
Framatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
013070 VESSEL INLET NOZZLES B-N-1 C VT-3 2004-EOC20-02 X - - - 10/25/2004 - VT-3 Complete.
INTERIOR SURFACES B13.10 No Recordable Indications.
Framatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
DATE: 02/15/05 TURKEY POINT THIRD INTERVAL [TP33 - UNIT 3 PAGE: 15 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 3, PERIOD 3, OUTAGE 3 (04)
CLASS 1 C COMPONENTS REACTOR PRESSURE VESSEL 3-001 ASME SEC. XI rSTATUS N ON I
G 0
T RS E H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I0 E NNHBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C GM R **CALIBRATION BLOCK*"
(REF. DWG. NO. 3-V01) 013090 VESSEL TO CLOSURE HEAD B-N-1 C VT-3 2004-EOC20-02 X - - - 10/23/2004 - VT-3 Complete.
MATING SURFACE ON B13.10 No Recordable Indications.
VESSEL Framatome's parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
013200 REACTOR VESSEL B-N-1 C VT-3 2004-EOC20-02 X - - - 10/23/2004 - VT-3 Complete.
CORE SUPPORT LEDGE B13.10 No Recordable Indications.
SURFACES Framatome'B parent document for the Reactor Pressure Vessel 10-year examination is 54-5054158-00.
(REF. DWG. NO. 5613-M-4001) 014600 3-LIG-1 THERU 18 B-G-1 C UT TP3-01-04 X - - - 10/31/2004 - UT Complete.
THREADS IN FLANGE B6.40 No Recordable Indications.
Limited examination close to vessel edge due to seal surface. Total coverage obtained for ligaments is 84.67%. Pramatome's parent cocument for the Reactor Pressure Vessel 10-year examination is 54-5054158-00. **UT-14**
014700 3-LIG-19 THRU 40 B-G-1 C UT TP3-01-04 X - - - 10/31/2004 - UT Complete.
THREADS IN FLANGE B6.40 No Recordable Indications.
Limited examination close to vessel edge due to seal surface. Total coverage obtained for ligaments is 84.67%. Framatome's parent cocument for the Reactor Pressure Vessel 10-year examination is 54-5054158-00. **UT-14**
DATE: 02/15/05 TURKEY POINT THIRD INTERVAL ITP3] - UNIT 3 PAGE: 16 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 3, PERIOD 3, OUTAGE 3 (04)
CLASS 1 C COMPONENTS REACTOR PRESSURE VESSEL 3-001 ASME _STATUS NI 0 SEC. XI ON G T R SE H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G MR **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-M-4001) 014800 3-LIG-41 THRU 58 B-G-1 C UT TP3-01-04 X - - - 10/31/2004 - UT Complete.
THREADS IN FLANGE B6.40 No Recordable Indications.
Limited examination close to vessel edge due to meal surface. Total coverage obtained for ligaments is 84.67%. Framatome's parent cocument for the Reactor Pressure Vessel 10-year examination in 54-5054158-00. **UT-14**
DATE: 02/15/05 TURKEY POINT THIRD INTERVAL ETP3] - UNIT 3 PAGE: 17 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 3, PERIOD 3, OUTAGE 3 (04)
CLASS I C COMPONENTS PRESSURIZER 3-006 ASME _SSASUS N I 0 SEC. XI O NTG R SE H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK"*
(REF. DWG. NO. 5613-M-4002) 042100 3-PCW-4 B-B C UT NDE S.1 - - - - 10/12/2004 - UT complete.
HEAD TO LOWER SHELL B2.11 OL2.25WRV X - - - No Recordable Indications.
45S2.25AX X - - - Limited scans due to 11 45S2.25CIR x - - -
60S2.25AX X - - - lines and welded pads.
60S2.25CIR X - - - **UT-a**
042200 3-PLW-3 B-B C UT 5.1-001 - - - - 10/12/2004 - UT complete.
LOWER SHELL LONG SEAM B2.12 0L2.25WRV X - - - No Recordable Indications.
45S2.25AX X - - - **UT-6**
45S2.25CIR X - - -
60S2.25AX X - - -
60S2.25CIR X - - -
DATES 02/15/05 TURKEY POINT THIRD INTERVAL CTP3] - UNIT 3 PAGE: 18 REVISION: a INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 3, PERIOD 3, OUTAGE 3 (04)
CLASS 1 C COMPONENTS REACTOR COOLANT SYSTEM LOOP B 1HOT LEG 3-011 ASME _SATSV N I 0 SEC. XI O N GT R S E H
SUMMARY
EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G MR **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-766-S SE. 2) 047100 29"-RCS-1305-1 R-A C UT 54-5054158-00 X - - - 10/19/2004 to 10/23/2004 -
RPV NOZZLE TO PIPE R1.11 UT Complete. No Recordable indications. 100% CRV Achieved. **UT-12, UT-32, UT-46**
DATE: 02/15/05 TURKEY POINT THIRD INTERVAL [TP3] - UNIT 3 PAGE: 19 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 3, PERIOD 3, OUTAGE 3 (04)
CLASS 1 C COMPONENTS REACTOR COOLANT SYSTEM LOOP C COLD LEG In A e-4-u )
ASME -STATUS N o0 SEC. XI ON G T R SE H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C GM R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-766-S SH. 3) 051000 27.5'-RCS-1309-14 R-A C UT 54-5054158-00 X - - - 10/19/2004 to 10/23/2004 -
ELBOW TO RPV NOZZLE Rl.11 UT Complete. No Recordable Indications. 100% CRV Achieved. **UT-26R, UT-32**
DATEt 02/15/05 TURKEY POINT THIRD INTERVAL [TP3] - UNIT 3 PAGE: 20 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 3, PERIOD 3, OUTAGE 3 (04)
CLASS 1 C COMPONENTS REACTOR COOLANT SYSTEM PRESSURIZER RELIEF LINE 3-022 AME N I 0 SEC. XI O N G T R S E 8
SUMMARY
EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C 0 M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-660-S SE. 1) 070700 3--RC-1304-1 R-A C UT 5.4-007 - - - - 10/16/2004 - UT complete.
REDUCER TO ELBOW Rl.ll 45S5.OCIR X - - No Recordable Indications.
605.OAX X - - - **UT-44**
7052.25AX X - - -
071400 3"-RC-1305-1 R-A C UT 5.4-007 - - - - 10/16/2004 - UT complete.
REDUCER TO VALVE 3-536 Rl.ll 45S5.OCIR X - - - Root geometry observed.
6055.0AX _- - - **UT-44**
7052.25AX X - - -
DATE: 02/15/05 TURKEY POINT THIRD INTERVAL [TP3] - UNIT 3 PAGE: 21 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 3, PERIOD 3, OUTAGE 3 (04)
CLASS 1 C COMPONENTS RESIDUAL HEAT REMOVAL TO RC LOOP B COLD LEG 3-038 ASME - N I 0 SEC. XI O N GT R S ElH REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I OE NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G MR **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-S86-S SH. 1) 128650 10'-SI-1302-IA R-A C UT 5:4-008 - - - - 10/15/2004 - UT Complete.
ELBOW TO ELBOW Rl.ll 45S2.25AX - - - - No Recordable Indications.
45S2.25CIR
- UT-27**
60S2.25AX
DATE: 02/15/05 TURKEY POINT THIRD INTERVAL [TP3l - UNIT 3 PAGE: 22 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 3, PERIOD 3, OUTAGE 3 (04)
CLASS 1 C COMPONENTS RESIDUAL HEAT REMOVAL TO RC LOOP C COLD LEG 3-039 ASME SEC. XI rSTATUS NI ON G 0
T R S E 8
SUMMARY
EXAMINATION AREA CATEGY EXAM REMARKS EI O E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET F C M R "CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-587-S S8. 2) 132500 SR-4 IA B-K C PT 3.3-003 X - - - 10/12/2004 - PT complete.
INTEGRAL ATTACHMENTS B10.20 No Recordable Indications.
DATE: 02/15/OS TURKEY POINT THIRD INTERVAL [TP3] - UNIT 3 PAGE: 23 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 3, PERIOD 3, OUTAGE 3 (04)
CLASS 1 C COMPONENTS HIGH HEAD SAFETY INJECTION LOOP A INSIDE CTMT 3 -u'3 ASME _STATUS N I 0 SEC. XI O N GT R S EH REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G MR **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-764-S SH. 2) 151500 8080-H-010-12 F-A C VT-3 4.3-007 - - - X 10/8/2004 - VT-3 complete.
SINGLE ACTING PF.10 Field verified clearances RESTRAINT differ from drawing. Actual field clearances in .60k instead of .75-.
Engineering Disposition:
use as-is. Reference CR 2004-10682.
151700 8080-H-010-13 F-A C VT-3 4.3-033 X - - - 10/8/2004 - VT-3 complete.
DOUBLE ACTING F1.10 No Recordable Indications.
RESTRAINT
DATE: 02/15/05 TURKEY POINT THIRD INTERVAL [TP3] - UNIT 3 PAGE: 24 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 3, PERIOD 3, OUTAGE 3 (04)
. CLASS 1 C COMPONENTS CHEMICAL & VOLUME CONTROL TO RC LOOP C HOT LEG 3-045 ASME c^-r N I 0 SEC. XI O N a T R S E H
SUMMARY
EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-661-S SH. 12 160300 PS-60 F-A C VT-3 4.3-03 9 X - - - 10/13/2004 - VT-3 complete.
DOUBLE ACTING P1.10 No Recordable Indications.
RESTRAINT (REF. DWG. NO. 5613-P-661-S SH. 2) 165200 SR-39 F-A C VT-3 4.3-036 X - - - 10/13/2004 - VT-3 complete.
DOUBLE ACTING F1.10 No Recordable Indications.
RESTRAINT
DATE: 02/15/05 TURKEY POINT THIRD INTERVAL ETP3] - UNIT 3 PAGE: 25 REVISION: INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 3, PERIOD 3, OUTAGE 3 (04)
CLASS 1 C COMPONENTS REACTOR COOLANT PUMP C 3-058 ASME _STATUS N I 0 SEC. XI O N 0 T R S E H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I O E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C 0 M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-M-4008) 203100 3-RCP-C-A B-L-1 C VT-1 4.1-012 X - - - 10/9/2004 - VT-1 complete.
PUMP CASING WELD A 812.10 No Recordable Indications.
203200 3-RCP-C-B B-L-1 C VT-1 4.1-013 X - - - 10/9/2004 - VT-1 complete.
PUMP CASING WELD B B12.10 No Recordable Indications.
203300 3-RCP-C-C B-L-1 C VT-1 4.1-014 X - - - 10/9/2004 - VT-i complete.
PUMP CASING WELD C B12.10 No Recordable Indications.
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 1 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS FR REACTOR PRESSURE VESSEL 3-001 ASME TUS N I 0
SUMMARY
NUMBER EXAMINATION AREA IDENTIFICATION SEC. XI CATEGY ITEM NO EXAM METHOD DATA SHEET #
E C
O N I
G ET S E0 M
HREAS E
R REMARKS
- CALIBRATION BLOCK**
(REF. DWG. NO. 5613-M-4000) 001800 3-WH-12 B-A R MT NDE 2.2 **UT-2**
FLANGE TO DOME WELD B1.40 UT NDE 5.1 003200 VESSEL TO CLOSURE READ B-N-1 R VT-3 NDE 4.3 SURFACE ON HEAD B13.10 003201 VESSEL TO CLOSURE HEAD B-N-1 B VT-3 4.3-048 X - - - 10/27/2004 - VT-3 complete.
MATING SURFACE ON HEAD B13.10 No Recordable Indications.
Baseline examination.
038000 3-LIFTINGLUG-1 B-H B PT 54-ISI-240 X - - - 8/10/2004 - PT Complete. No LIFTING LUG AT 60 54-PT-200 X - - - Recordable Indications.
DEGREES 10/1/2004 - PT Complete.
Assembly marks were observed on the lifting lugs after the arrival on site. The damage happened during shippment and after baseline examination was complete.
Reference CR 2004-2285.
038010 3-LIFTINGLUG-2 B-H B PT 54-ISI-240 X - - - 8/10/2004 - PT Complete. No LIFTING LUG AT 180 54-PT-200 X - - - Recordable Indications.
DEGREES 10/1/2004 - PT Complete.
Assembly marks were observed on the lifting lugs after the arrival on site. The damage happened during shippment and after baseline examination was complete.
Reference CR 2004-2285.
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 2 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS REACTOR PRESSURE VESSEL 3-001 ASME T-SATUS N I 0 SEC. XI O N GT R S E H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G MR **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-M-4000) 038020 3-LIFTINGLUG-3 B-H B PT 54-ISI-240 X - - - 8/10/2004 - PT Complete. No LIFTING LUG AT 300 54-PT-200 X - - - Recordable Indications.
DEGREES 10/1/2004 - PT Complete.
Assembly marks were observed on the lifting lugs after the arrival on site. The damage happened during shippment and after baseline examination was complete.
Reference CR 2004-2285.
038030 3-SUPPORTLUG-1 B-H B PT 54-ISI-240 - - - - 8/11/2004 - PT Complete. No SUPPORT LUG AT 0 Recordable Indications.
DEGREES 038040 3-SUPPORTLUG-2 B-H B PT 54-ISI-240 X - - - 8/11/2004 - PT Complete. No SUPPORT LUG AT 120 Recordable Indications.
DEGREES 038050 3-SUPPORTLUG-3 B-H B PT 54-ISI-240 X - - - 8/11/2004 - PT Complete. No SUPPORT LUG AT 240 Recordable Indications.
DEGREES 038100 3-CRDM-59 (PS) B-O B PT 54-ISI-240 X - - - 8/11/2004 - PT Complete. No CRDM Housing Weld B14.10 Recordable Indications.
038110 3-CRDM-64 (P6) B-O B PT 54-ISI-240 X - - - 8/11/2004 - PT Complete. No CRDM Housing Weld B14.10 Recordable Indications.
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 3 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS REACTOR PRESSURE VESSEL 3-001 ASME _STASUS N I 0 SEC. XI O NG S R S E H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I0 E NUMEER IDENTIFICATION ITEM NO METEOD DATA SHEET # C GM R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-M-4000) 038120 3-CRDM-32 (M6) B-O B PT 54-ISI-240 X - - - 8/11/2004 - PT Complete. No CRDM Housing Weld B14.10 Recordable Indications.
038130 3-CRDM-27 (L5) B-0 B PT 54-ISI-240 X - - - 8/11/2004 - PT Complete. No CRDM Housing Weld B14.10 Recordable Indications.
038140 3-CRDM-53 (L3) B-0 B PT 54-ISI-240 X - - - 8/11/2004 - PT Complete. No CRDM Housing Weld B14.10 Recordable Indications.
038150 3-CRDM-65 (K2) B-O B PT 54-ISI-240 X - - - 8/11/2004 - PT Complete. No CRDM Housing Weld B14.10 Recordable Indications.
038160 3-CRDM-60 (H2) B-0 B PT 54-ISI-240 X - - - 8/11/2004 - PT Complete. No CRDM Housing Weld B14.10 Recordable Indications.
038170 3-CRDM-66 (F2) B-0 B PT 54-ISI-240 X - - - 8/11/2004 - PT Complete. No CRDM Housing Weld B14.10 Recordable Indications.
038180 3-CRDM-34 (F4) B-0 B PT 54-ISI-240 X - - - 8/11/2004 - PT Complete. No CRDM Housing Weld B14.10 Recordable Indications.
038190 3-CRDM-28 (ES) B-0 B PT 54-ISI-240 X - - - 8/11/2004 - PT Complete. No CRDM Housing Weld B14.10 Recordable Indications.
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 4 REVISIONt 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS REACTOR PRESSURE VESSEL 3-001 ASME _STATUS N I 0 SEC. XI 0 N G T R SE H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I OE NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET N C G MR **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-M-4000) 038200 3-CRDM-55 (CS) B-O B PT 54-ISI-240 X - - - 8/11/2004 - PT Complete. No CRDM Housing Weld B14.10 Recordable Indications.
038210 3-CRDM-67 (B6) B-O B PT 54-ISI-240 X - - - 8/11/2004 - PT Complete. No CRDM Housing Weld B14.10 Recordable Indications.
038220 3-CRDM-61 (B8) B-0 B PT 54-ISI-240 X - - - 8/11/2004 - PT Complete. No CRDM Housing Weld B14.10 Recordable Indications.
038230 3-CRDM-68 (B10) B-0 B PT 54-ISI-240 X - - - 8/11/2004 - PT Complete. No CRDM Housing Weld B14.10 Recordable Indications.
038240 3-CRDM-36 CD10) B-0 B PT 54-ISI-240 X - - - 8/11/2004 - PT Complete. No CRDM Housing Weld B14.10 Recordable Indications.
038250 3-CRDM-29 (Ell) B-O B PT 54-ISI-240 X - - - 8/11/2004 - PT Complete. No CRDM Housing Weld B14.10 Recordable Indications.
038260 3-CRDM-57 (E13) B-0 B PT 54-ISI-240 X - - - 8/11/2004 - PT Complete. No CRDM Housing Weld B14.10 Recordable Indications.
038270 3-CRDM-69 (F14) B-0 B PT 54-ISI-240 X - - - 8/11/2004 - PT Complete. No CRDM Housing Weld B14.10 Recordable Indications.
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 5 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS REACTOR PRESSURE VESSEL 3-001 ASME _STATUS N I 0 SEC. XI 0 N G T R S E H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXA M E I O E NUMBER IDENTIFICATION ITEM NO METH HOD DATA SHEET # C 0 M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-M-4000) 038280 3-CRDM-58 (H14) B-O B PT 54-ISI-240 X - - - 8/11/2004 - PT Complete. No CRDM Housing Weld B14.10 Recordable Indications.
038290 3-CRDM-62 (K14) B-O B PT 54-ISI-240 X - - - 8/11/2004 - PT Complete. No CRDM Housing Weld B14.10 Recordable Indications.
038300 3-CRDM-30 CK12) B-O B PT 54-lSI-240 X - - - 8/11/2004 - PT Complete. No CRDM Housing Weld B14.10 Recordable Indications.
038310 3-CRDM-26 (Lll) B-O B PT 54-ISI-240 X - - - 8/11/2004 - PT Complete. No CRDM Housing Weld B14.10 Recordable Indications.
038320 3-CRDM-51 (Nll) B-O B PT 54-ISI-240 X - - - 8/11/2004 - PT Complete. No CRDM Housing Weld B14.10 Recordable indications.
038330 3-CRDM-63 (P10) B-O B PT 54-ISI-240 X - - - 8/11/2004 - PT Complete. No CRDM Housing Weld B14.10 Recordable Indications.
038400 3-WH-14-1 THRU 65 R PT NDE 3.3 CRDM Housing Welds
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 6 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS STEAM GENERATOR B PRIMARY SIDE 3-004 ASME -SSATUS N I 0 SEC. XI 0 N GT R S E H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I O E NUMBER IDENTIFICATION ITEM NO METEOD DATA SHEET If C a MR "CALIBRATION BLOCK" (REF. DWG. NO. 5613-M-4004) 040200 3-SGB-Z B-B C UT 5.1-004 - - - - 10/18/2004 - UT complete.
READ TO TUBESHEET WELD B2.40 45S2.25AX - - - X Numerous casting voids 45S2.25CIR - - - X recorded. Verified by 60S2.25AX - - - x 60S2.25CIR - - - X radiographs. **UT-"**
OL2.25WRV _ - - X 040300 3-SGB-I-IRS B-D C VT 4.8-003 X - - - 10/15/2004 - Enhanced Visual INLET NOZZLE INNER B3.140 complete. No Recordable RADIUS SECTION Indications. **STEAM GENERATOR MOCK-UP**
040400 3-SGB-O-IRS B-D C VT 4.8-004 X - - - 10/15/2004 - Enhanced Visual OUTLET NOZZLE INNER B3.140 complete. No Recordable RADIUS SECTION Indications. **STEAM GENERATOR MOCK-UP**
040500 3-SGB-I BOLTING B-G-2 C VT-l 4.1-016 X - - - 10/12/2004 - VT-l complete.
STEAM GENERATOR INLET B7.30 No Recordable Indications.
MANWAY BOLTING 040600 3-SGB-O BOLTING B-G-2 C VT-i 4.1-015 X - - - 10/12/2004 - VT-1 complete.
STEAM GENERTOR OUTLET B7.30 No Recordable Indications.
MANWAY BOLTING
DATE: 02/15/05 TURKEY POINT - UNIT 3 PACE: 7 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS STEAM GENERATOR C PRIMARY SIDE 3-005 ASME .TATUS N I 0 SEC. xi O N T
SUMMARY
EXAMINATION AREA CATEGY EXAMIE R SI 0E HE REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C C M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-M-4005) 041100 3-SGC-I-IRS B-D C VT 4.8-002 X - - - 10/15/2004 - Enhanced Visual INLET NOZZLE INNER B3.140 complete. No Recordable RADIUS SECTION Indications. **STEAM GENERATOR MOCK-UP**
041200 3-SGC-O-IRS B-D C VT 4.8-001 - - - X 10/15/2004 - Enhanced Visual OUTLET NOZZLE INNER B3.140 UT 5.13-001 X - - - complete. Two linear RADIUS SECTION indications were found in the first clad bead on nozzle side, 3:00 and 4:00 facing nozzle from the ID.
Both indications across clad weld bead, approx. 0.75" long, weld bead total width approx. 0.75". Reference CR 2004-11026.
10/15/2004 - UT complete in the area of indications. No evidence of the linear indication propagating into the base material. **STEAM GENERATOR MOCK-UP**
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 8 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS PRESSURIZER 3-006 ASME _STATUS N I 0 SEC. XI ON G T R SE H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-M-4002) 043500 03-PZR-1 THRU 16 B-G-2 C VT-1 4.1-008 X - - - 11/01/2004 - VT-1 complete.
PRESSURIZER MANWAY B7.20 4.1-009 X - - - No Recordable Indications.
BOLTING Examined replacement studs 5
& 6. UTC #0000394210 and SC
- 0015171-1. Heavy Hex 1 7/8-8un 2A x 7 1/2" long with 4 1/4" threads. ASME SA193 Grade B7.
11/02/2004 - VT-l complete.
No Recordable Indications.
Examined studs 1 thru 4 and 7 thru 16. The remaining two studs were replaced and examined on data sheet 4.1-009.
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 9 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS REACTOR COOLANT SYSTEM LOOP B INTERMEDIATE LEG 3-010 ASME n--q N I 0 SEC. XI O N G T R S E E REMARXS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I O E NUMBER IDENTIFICATION ITEM NO MESEOD DATA SHEET # C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-766-S SE. 2) 046500 31"-RCS-1302-8 R-A C UT 5.4-001 - - - - 10/6/2004 - UT complete.
ELBOW TO PIPE R1.11 45L1.00AX X - - - Root geometry recorded.
6052.25AX - - X - **UT-12, UT-26R, UT-46**
4552.25CIR X - - -
UT 5.23-001 45L1.OOAX X - - -
45L1.00CIR X - - -
DATE: 02/15/05 TURXEY POINT - UNIT 3 PAGE: 10 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4. PERIOD 1, OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS REACTOR COOLANT SYSTEM PRESSURIZER SURGE LINE 3-016 ASME TATUS NI 0 SEC. XI ON a T R S E H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM EI 0 E NUMEER IDENTIFICATION ITEM NO METLOD DATA SHEET # CG M R **CALIBRATION BLOCK" (REF. DWG. NO. 5613-P-766-S SH. 2) 051400 12'-RC-1301-1 R-A C UT 5.4-002 - - - - 10/7/2004 - UT complete. No BRANCH CONNECTION TO Rlll 45S2.25AX X - - - recordable Indications.
45S2.25CIR X - - - Scan ie limited from the PIPE branch connection side.
- UT-34**
051800 VS-1G-12 F-A C VT-3 4.3-032 X - - - 10/06/2004 - VT-3 complete.
DUAL SPRING HANGER F1.10 No Recordable Indications.
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 11 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS REACTOR COOLANT SYSTEM PRESSURIZER SAFETY LOOP A 3-017 xa_ N I 0 SASUS To SEC. XI O N G T R S E H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALI8RASION BLOCK**
(REF. DWG. NO. 5613-P-660-S SH. 3) 052700 41-RC-1301-1A R-A C RT 9.3-001 X - - - 10/18/2004 - RT complete.
NOZZLE TO SAFE-END Rl.11 No Recordable Indications.
053800 40-RC-1301-FB B-G-2 C VT-1 4.1-006 X - - - 10/04/2004 - VT-1 complete.
PIPING FLANGE BOLTING B7.50 No Recordable Indications
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 12 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS REACTOR COOLANT SYSTEM PRESSURIZER SAFETY LOOP B 3-0189vr IL N I 0 XATuV SEC. XI O N G T R S E H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-660-S SH. 3) 054100 4'-RC-1302-1A R-A C RT 9.3-002 X - - - 10/18/2004 - RT complete.
NOZZLE TO SAFE-END Rl.11 No Recordable Indications.
- UT-53**
055200 4"-RC-1302-FB B-G-2 C VT-1 4.1-007 X - - - 10/04/2004 - VT-1 complete.
PIPING FLANGE BOLTING B7.50 No Recordable Indications
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 13 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS REACTOR COOLANT SYSTEM PRESSURIZER SAFETY LOOP C 3-019 N I 0 1-STATUS SEC. XI O N G T R S E H
SUMMARY
EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-660-S SE. 2) 055500 4'-RC-1303-1A R-A C RT 9.3-003 X - - - 10/18/2004 - RT complete.
NOZZLE TO SAFE-END Rl.l1 No Recordable Indications.
- UT-53**
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 14 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS REACTOR COOLANT SYSTEM PRESSURIZER SPRAY TO PRZ.
3-020 ASME TATUS N I 0 SEC. XSI_ O N G T R S E H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-661-S SH. 4) 062100 4"-RC-1304-1A R-A C RT 9.3-004 X - - - 10/18/2004 - RT complete.
SAFE-END TO NOZZLE Rl.ll No Recordable Indications.
- UT-53**
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 15 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1. OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS REACTOR COOLANT SYSTEM PRESSURIZER RELIEF LINE 3-022 ASE cr N I 0 SEC. XI O N TS R S E H
SUMMARY
EXAMINATION AREA CATEGY EXAM REMARKS E I 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET F C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-660-S SR. 1) 068700 4"-RC-1306-KA R-A C RT 9.3-005 - - - X 10/18/2004 - RT complete.
NOZZLE TO SAFE-END R1.11 Acceptable porosity observed in weld. **UT-53**
069500 3-RCH-27 F-A C VT-3 4.3-029 X - - - 10/04/2004 - VT-3 complete.
SPRING HANGER F1.10 No Recordable Indications.
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 16 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS REACTOR COOLANT SYSTEM AUXILIARY SPRAY LINE 3-035 A am -- N I 0 SEC. XI O N G S R S E H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I O E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK"*
(REF. DWG. NO. 5613-P-661-S SH. 2) 114400 2'-RC-1310-2 R-A C VT-2 4.2-001 X - - - 9/26/2004 - VT-2 complete.
VALVE 3-313 TO PIPE R1.12 No Recordable Indications.
- US-54**
120900 2'-RC-1310-38 R-A C VT-2 4.2-001 X - - - 9/26/2004 - VT-2 complete.
REDUCER TO PIPE R1.12 No Recordable Indications.
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 17 REVISION: INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS RESIDUAL BEAT REMOVAL TO RC LOOP B COLD LEG 3-038 AxMt -- N I 0 SEC. XI O N G T R S E H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E O0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-586-S SH. 1) 128000 10--SI-1302-5 R-A C UT NDE 5.4 - - - - 10/15/2004 - UT complete.
PIPE TO ELBOW R1.11 4552.25AX X - - - Root geometry recorded.
45S2.25CIR X - - - Also non-metallic inclusion 60S2.25AX - - X -
observed outside the examiantion volume.
Verified by 0 degree.
- UT-27**
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 18 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS RESIDUAL HEAT REMOVAL TO RC LOOP C COLD LEG 3-039 A5 -- N I 0 STATUS SEC. XI O N GT R SE H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET# C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-587-S SH. 2) 131700 VALVE 3-875F B-M-2 C VT-3 4.3-046 X - - - 10/11/2004 - VT-3 complete.
VALVE INTERNAL SURFACE B12. 50 No Recordable Indications.
131800 VALVE 3-875F BOLTING B-G-2 C VT-1 4.1-017 X - - - 10/11/2004 - VT-I complete.
VALVE BOLTING B7.70 Light Surface Corrosion.
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 19 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS HIGH HEAD SAFETY INJECTION LOOP B INSIDE CTMT 3-041 ASME ,-STATUS N I 0 SEC. XI O N G T R S E H
SUMMARY
EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO MET11D DATA SHEET # C G M R **CALIBRATION BLOCK-*
(REF. DWG. NO. 5613-P-584-S 51. 1) 143100 HGR#4 F-A C VT-3 4.3-026 X - - - 10/03/2004 - VT-3 complete.
SINGLE ACTING F1.10 No Recordable Indications.
RESTRAINT
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 20 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS HIGH HEAD SAFETY INJECTION LOOP C INSIDE CTMT J -UGZ ASME STATUS NI 0 SEC. XI ON G T R S E H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM EI 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-648-S SH. 1) 144800 SUPPORT F F-A A VT-3 4.3-051 X - - - 10/29/2004 - VT-3 complete.
DOUBLE ACTING Fl.10 No Recordable Indications.
RESTRAINT This hanger was removed by maintanence during the Spring 2003 refueling outage and not reinstalled.
Reference CR 2004-10639.
Also the hanger design was modified. Reference CRN-C-11369 and MRA CR-04-10639-01.
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 21 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS HIGH READ SAFETY INJECTION LOOP B INSIDE CTMT 3-044 AM r N I 0 SEC. XI O N G T R S E H
SUMMARY
EXAMINATION AREA CATEGY EXAM I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO £ METHOD DATA SHEET #
E C a M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-764-S SH. 1) 157000 8080-H-009-07 F-A C VT-3 4.3-014 X - - - 10/03/2004 - VT-3 complete.
SINGLE AND DOUBLE F1.10 No Recordable Indications.
ACTING RESTRAINT 158400 8080-H-009-05 F-A C VT-3 4.3-012 X - - - 10/03/2004 - VT-3 complete.
DOUBLE ACTING F1.10 No Recordable Indications.
RESTRAINT
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 22 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4. PERIOD 1, OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS CHEMICAL & VOLUME CONTROL TO RC LOOP C HOT LEG 3-045 lc Qa NI 0 SEC. XI ON G T R S E H
SUMMARY
EXAMINATION AREA CATEGY EXAM REMARKS EI 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R "CALIBRATION BLOCK**
(REP. DWG. NO. 5613-P-661-S SH. 1) 160800 3-VCH-114 F-A E VT-3 4.3-008 X 10/14/2004 - VT-3 complete.
SPRING HANGER F1.10 4.3-052 X - - - This hanger was examined as part of the expanded sample for 3-VCH-115. Reference CR 2004-9153. The spring setting is out of tolerance.
Reference CR 2004-11013.
Engineering Disposition:
Reset spring setting to the cold setting. Reference WO 34017723-02 11/05/2004 - VT-3 complete.
No Recordable Indications.
Reexamination after Interim
- 1 corrective action and WO 34017723-02. Spring hanger was reset.
161900 3-VCH-115 F-A C VT-3 4.3-001 - - - X 9/30/2004 - VT-3 complete.
DOUBLE ACTING 11.10 4.3-049 X - - - Stanchion support is bent RESTRAINT approximately 30 down from intergrally attached weld.
Stanchion is toed at the guide plate, unable to slide, and the cleatrance os 0" where the sliding stanchion meets thr guide plate. Engineering disposition: The support is to be modified per MRA CR 04-9153-01 to SPEC-C-024 and WO 34017723. Reference CR 2004-9153.
10/28/2004 - VT-3 complete.
No Recordable Indications.
Reexamination after modification.
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 23 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS CHEMICAL & VOLUME CONTROL TO RC LOOP C HOT LEG 3-045 A aim N I 0 SEC. XI O N G T R S E H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-661-S SH. 1) 162000 3-VCH-115 IA B-K C PT 3.3-001 X - - - 9/30/2004 - PT complete. No INTEGRAL ATTACHMENT B10.20 Recordable Indications 162200 SR-64 F-A C VT-3 4.3-010 X - - - 9/30/2004 - VT-3 complete.
SPRING HANGER P1.10 No new Recorded Indications.
Reported previously identified conditions addressed by CRN on hanger drawing. Incomplete thread engagement and gouge on base plate.
_____________REF.D____N.____----_______________S_______________________________2_______________
(REF. DWG. NO. 5613-P-661-S SB. 2) 163500 SR-37 F-A E VT-3 4.3-040 X - - - 10/13/2004 - VT-3 complete.
WELDED STANCHION F1.10 No Recordable Indications.
Expanded sample per CR 2004-9153.
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 24 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS CHEMICAL & VOLUME CONTROL TO RC LOOP A COLD LEG 3-046 ASME --- NI 0 SEC. XI ON 0 T RS E H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM EI O E NUMBER IDENTIFICATION ITEM NO METZOD DATA SHEET # C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-661-S SH. 3) 167100 SR-63 F-A C VT-3 4.3-047 X - - - 10/21/2004 - VT-3 complete.
DOUBLE ACTING F1.10 No Recordable Indications.
RESTRAINT 168700 3-VCH-120 F-A C VT-3 4.3-016 X - - - 10/03/2004 - VT-3 complete.
SINGLE ACTING F1.10 No Recordable Indications.
RESTRAINT 169400 PS-1 F-A C VT-3 4.3-017 X - - - 10/03/2004 - VT-3 complete.
DOUBLE ACTING P1.10 No Recordable Indications.
RESTRAINT
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 25 REVISION: 0 lNSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS CHEMICAL & VOLUME CONTROL FROM THE REGENERATIVE HX 3-049 A N I 0
,....STATUS SEC. XI O N G T R S E H
SUMMARY
EXAMINATION AREA CATEGY EXAM REMARKS E I 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET# C G M R *-CALIBRATION BLOCX**
(REF. DWG. NO. 5613-P-644-S SH. 3) 177900 422-A F-A C VT-3 4.3-045 X - - - 10/21/2004 - VT-3 complete.
DOUBLE ACTING F1.10 No Recordable Indications.
RESTRAINT
_______________F._DGNO.____----_______________S_______________________________2)_____________
(REP. DWG. NO. 5613-P-644-S SH. 2) 179600 423-C F-A C VT-3 4.3-043 X - - - 10/14/2004 - VT-3 complete.
DOUBLE ACTING F1.10 No Recordable Indications.
RESTRAINT
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 26 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 1 C8EAR COMPONENTS CHEMICAL & VOLUME CONTROL SEAL INJECTION LOOP A 3-050 AMrwn N I 0 SEC. XI O N G T R S E H REMARKS SBMMARY EXAMINATION AREA CATEGY EXAM E I O E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK*"
(REF. DWG. NO. 5613-P-5070 SH. 1) 181140 1-CH-1351-l R-A C VT-2 4.2-002 X - - - 9/26/2004 - VT-2 complete.
RCP 3P-200A TO PIPE R1.12 No Recordable Indications.
181148 3/4"-CH-1357-2 R-A C VT-2 4.2-002 X - - - 9/26/2004 - VT-2 complete.
1" x 3/4" REDUCER TO R1.12 No Recordable Indications.
PIPE 181190 1-CH-1348-3 R-A C VT-2 4.2-002 X - - - 9/26/2004 - VT-2 complete.
REDUCER TO FLANGE R1.12 No Recordable Indications.
181192 1"-CH-1354-1 R-A C VT-2 4.2-002 X - - - 9/26/2004 - VT-2 complete.
FLANGE TO 1" x 3/4" R1.12 No Recordable Indications.
REDUCER
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 27 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS CHEMICAL & VOLUME CONTROL SEAL INJECTION LOOP C 3-051 ASME TATUS N I 0 SEC. XI O N a T R S E H
SUMMARY
EXAMINATION AREA CATEGY EXAM REMARKS E I O E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-5070 SH. 1) 182800 l'-CH-1353-1 R-A C VT-2 4.2-003 X - - - 9/26/2004 - VT-2 complete.
RCP 3P-200C TO PIPE Rl.12 No Recordable Indications.
182809 3/40-CH-1359-6 R-A C VT-2 4.2-003 X - - - 9/26/2004 - VT-2 complete.
ELBOW TO PIPE R1.12 No Recordable Indications.
182820 1'-CH-1350-3 R-A C VT-2 4.2-003 X - - - 9/26/2004 - VT-2 complete.
REDUCER TO FLANGE R1.12 No Recordable Indications.
182825 3/4'-CH-1356-5 R-A C VT-2 4.2-003 X - - - 9/26/2004 - VT-2 complete.
PIPE TO ELBOW R1.12 No Recordable Indications.
(REF. DWG. NO. 5613-P-5071 S8. 3) 182836 3/4'-CH-1341A-2 R-A C VT-2 4.003 X - - - 9/26/2004 - VT-2 complete.
CONNECTION TO PIPE Rl.12 No Recordable Indications.
182838 3/4'-CH-1341B-1 R-A C VT-2 4.003 X - - - 9/26/2004 - VT-2 complete.
FLANGE TO PIPE R1.12 No Recordable Indications.
182854 3/4'-CH-1344-5 R-A C VT-2 4.2-003 X - - - 9/26/2004 - VT-2 complete.
VALVE 3-304L TO PIPE R1.12 No Recordable Indications.
_____________(RF._DGNO.____----______________________________________________________________
(REF. DWG. NO. 5613-P-646-S S8. 1)
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 28 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS CHEMICAL & VOLUME CONTROL SEAL INJECTION LOOP C 3-051 A ev
- - NI 0 SATUS W
SEC. XI 0N G T R S E H
SUMMARY
EXAMINATION AREA CATEGY EXAM EI 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C GM R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-646-S SH. 1) 185300 H-4 F-A C VT-3 4.3-015 X - - - 10/03/2004 - VT-3 complete.
DOUBLE ACTING F1.10 No Recordable Indications.
RESTRAINT
I DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 29 REVISION: INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS CHEMICAL & VOLUME CONTROL SEAL INJECTION LOOP B 3-052 AS N I 0 STATU SEC. XI O N G S R S E H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-5070 SE. 1) 185798 1--CH-1352-1 R-A C VT-2 4.2-004 X - - - 9/26/2004 - VT-2 complete.
RCP 3P-200B TO PIPE R1.12 No Recordable Indications.
185805 3/4*-CH-1358-4 R-A C VT-2 4.2-004 X - - - 9/26/2004 - VT-2 complete.
ELBOW TO PIPE R1.12 No Recordable Indications.
185819 1-CH-1349-2 R-A C VT-2 4.2-004 X - - - 9/26/2004 - VT-2 complete.
PIPE TO REDUCER R1.12 No Recordable Indications.
185824 3/41-CH-1355-3 R-A C VT-2 4.2-004 X - - - 9/26/2004 - VT-2 complete.
PIPE TO ELBOW R1.12 No Recordable Indications.
(REF. DWO. NO. 5613-P-645-S SH. 2) 185900 l.SN-CH-1303-FBl B-G-2 C VT-1 4.1-004 X - - - 10/03/2004 - VT-1 complete.
PIPING FLANGE BOLTING B7.SO No Recordable Indications 186400 H-4 F-A C VT-3 4.3-034 X - - - 10/12/2004 - VT-3 complete.
DOUBLE ACTING F1.10 No Recordable Indications.
RESTRAINT 187000 2"-CH-1305-FB2 B-G-2 C VT-1 4.1-003 X - - - 10/03/2004 - VT-1 complete.
PIPING FLANGE BOLTING B7.50 No Recordable Indications
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 30 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 1 CBEAR COMPONENTS CHEMICAL & VOLUME CONTROL, REGENERATIVE HEAT EXCH 3-059 .ASME TATUS NI 0 SEC. XI ON G T R S E H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM EI O E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK"*
(REF. DWG. NO. 5613-M-4009) 204100 RGX 3E200 C VT-2 4.2-005 X - - - 9/26/2004 - VT-2 Complete VISUAL FOR LEAKAGE VT-2 4.2-006 X - - - for Shutdown. No Recordable Indications.
11/27/2004 - VT-2 Complete for Startup. No Recordable Indications.
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 31 REVISION: INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1. OUTAGE 1 (04)
CLASS 2 CBEAR COMPONENTS STEAM GENERATOR B SECONDARY SIDE 3-061 ASME _STATUS N I 0 SEC. XI O N G T R S E H REMARKS
SUMMARY
EXAMINATION AREA CCATEGY EXAM E I 0 E NUMBER IDENTIFICATION I TEM NO METHOD DATA SHEET # C a M R **CALIBRATION BLOCK" (REF. DWG. NO. 5613-M-4004) 210800 3-SGB-G C-A C UT 5.1-003 10/15/2004 - UT complete.
LOWER INTERMEDIATE C1.10 45S2.25AX x - - - No Recordable Indications.
45S2.25CIR S - - -
SHELL TO TRANSITION **UT-7**
60S2.25AX X - - -
60S2.25CIR X - - -
OL2.25WRV X - - -
210900 3-SGB-CL C-A C UT 5.1-003 - - - - 10/20/2004 - UT complete.
TRANSITION TO UPPER C1.10 45S2.25AX - - - X Slag inclusions observed in SHELL WELD 452.2SCIR X - - - several locations throughout 60S2.25AX - - - I 60S2.25CIR X - - - the weld. Verified by OL2.25WRV X - - - radiographs. **UT-7**
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 32 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 2 CBEAR COMPONENTS STEAM GENERATOR C SECONDARY SIDE 3-062 ASME SATUS N I 0 SSEC. XI O N G T R S E H REMARKS
SUMMARY
EXAMINATION AREA C ATEGY EXA M E I O E NUMBER IDENTIFICATION I TEM NO METS HD DATA SHEET # C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-M-4005) 212610 3-SGC-SS C VT 4.4-001 X - - - 10/07/2004 - VT Complete.
SECONDARY SIDE No Recordable Indications.
EXAMINATION
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 33 REVISION: INSERVICE INSPECTION RESULTS
SUMMARY
0 INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 2 CBEAR COMPONENTS RESIDUAL HEAT REMOVAL TO RESID.HEAT REMOVAL PUMP A 3-063 A Quv N I 0 SEC. xI 0 N G T R S E H
SUMMARY
EXAMINATION AREA CATEGY EXAM REMARKS E I 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-669-S SH. 1) 212900 14--RER-2301-1 C-F-1 C PT 3.3-006 X - - - 10/12/2004 - PT complete.
VALVE 3-751 TO ELBOW C5.11 UT 5.4-004 - - - - No Recordable Indications.
45S2.25AX X - - - 10/13/2004 - UT complete.
4552.25CIR x - - -
60S2.25AX x - - - No Recordable Indications.
70S2.25AX X - - - **UT-33**
213100 141-RHR-2301-2 C-F-1 C PT 3.3-006 X - - - 10/12/2004 - PT complete.
ELBOW TO PIPE C5.11 UT 5.4-003 - - - - No Recordable Indications 4655.OCIR X - - - 10/12/2004 - UT complete.
60S5.OAX X - - -
No recordable Indications.
- UT-33**
213700 141-RHR-2301-4 C-F-1 C PT 3.3-004 X - - - 10/09/2004 - PT complete.
ELBOW TO ELBOW C5.11 UT 5.4-005 - - - - No Recordable Indications.
4555.OCIR X - - - 10/9/2004 - UT complete. No 6055.OAX X - - -
Recordable Indications.
- UT-33**
214200 14--RER-2301-5 C-F-1 C PT 3.3-004 X - - - 10/09/2004 - PT complete.
ELBOW TO PIPE CS.11 UT 5.4-006 - - - - No Recordable Indications.
4555.OCIR X - - - 10/09/2004 - UT complete.
6055.OAX X - - -
No Recordable Indications.
- UT-33**
214675 CONT. PENETRATION P-1 F-A C VT-3 4.3-041 X - - - 10/14/2004 - VT-3 complete.
ANCHOR F1.20 No Recordable Indications.
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 34 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 2 CBEAR COMPONENTS RESIDUAL HEAT REMOVAL TO RESID.HEAT REMOVAL PUMP A 3-063 ASME -TATUS N I 0 SEC. XI O N G T R S E B REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET t C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-669-S SH. 1) 214700 CONS. PENETRATION P-1 C-C C PT 3.3-005 X - - - 10/14/2004 - PT Complete.
INTEGRAL ATTACHMENT C3.20 No Recordable Indications (REF. DWG. NO. 5613-P-600-S SH. 1) 215700 SR-251 F-A C VT-3 4.3-006 X 10//2004 - VT-3 complete.
SPRING HANGER F1.20 4.3-050 X - - - Spring can setting is out of tolerance. Engineering Disposition: Reset spring can to the corrective action of Interim Disposition 2.
Reset cold setting to S/8" (769 pounds) Reference WO 33021794 and CR 2004-10252.
10/29/2004 - VT-3 complete.
No Recordable Indications.
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 35 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4. PERIOD 1, OUTAGE 1 (04)
CLASS 2 CBEAR COMPONENTS RESIDUAL HEAT REMOVAL TO RESID.HEAT REMOVAL PUMP B 3-064 %E ---- N I 0 SEC. XI O N G T R S E H
SUMMARY
EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK" (REF. DWG. NO. 5613-P-600-S SH. 1) 219400 PS-54 F-A R VT-3 NDE 4.3 DUAL SPRING HANGERS F1.20
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 36 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 2 CBEAR COMPONENTS RESIDUAL HEAT REMOVAL FROM CONTAINMENT SUMP B 3-067 ARME NI 0 SEC. XI ON G T R S E H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM EI 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # Ca M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-600-S SH. 2) 224200 SR-256 F-A C VT-3 4.3-030 X - - - 10/04/2004 - VT-3 complete.
DOUBLE ACTING P1.20 No Recordable Indications.
RESTRAINT
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 37 REVISION: INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 2 CBEAR COMPONENTS RESIDUAL HEAT REMOVAL SYSTEM INSIDE CONTAINMENT 3-085 AMqwn N I 0 SEC. XI O N G T R S E H
SUMMARY
EXAMINATION AREA CATEGY EXAAM REMARKS E I M E NUMBER IDENTIFICATION ITEM NO METE 'OD DATA SHEET # C a M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-586-S SE. 1) 262000 SR-54 P-A C VT-3 4.3-042 X - - - 10/04/2004 - VT-3 complete.
DOUBLE ACTING F1.20 No Recordable Indications.
RESTRAINT Actual clearance on top side of support is 1/32" instead of 1116". Clearance is acceptable per STD-C-001 R.1
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 38 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 2 CBEAR COMPONENTS HIGH HEAD SAFETY INJECTION OUTSIDE CONTAINMENT 3-095 IL rW7 N I 0
_SATXUSb SEC. XI O N G T R S E H
SUMMARY
EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK"*
(REF. DWG. NO. 5613-P-823-S SH. 2) 288720 8080-R-006-01 F-A C VT-3 4.3 -005 -. X 10/3/2004 - VT-3 complete.
DOUBLE ACTING F1.20 Field verified clearances RESTRAINT differ from drawing. Actual field clearances are 0" on top and bottom of restraint.
Engineering Disposition:
Use as-is. A CRN C-11333 (PC/M No.03-106 and ITOP
- 04-10-017) and MRA CR-04-10094-01 for SPEC C-017 will be issued.
Reference CR 2004-10094.
288723 8080-R-006-01 IA C-C C PT 3.3-002 X - - - 10/03/2004 - PT complete.
INTEGRAL ATTACHMENTS C3.20 No Recordable Indications 288787 8080-H-007-09 F-A C VT-3 4.3-028 X - - - 10/04/2004 - VT-3 complete.
DOUBLE ACTING F1.20 No Recordable Indications.
RESTRAINT
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 39 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 2 CBEAR COMPONENTS HIGH PRESSURE SAFETY INJECTION OUTSIDE CONTAINMENT 3-096 ASM NI 0 SEC. XI ON G T R S E H
SUMMARY
EXAMINATION AREA CATEGY EXAM EI 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK"*
(REF. DWG. NO. 5613-P-597-S SH. 3) 289063 C F-A C VT-3 4.3-003 - - X 10/3/2004 - VT-3 complete.
SINGLE ACTING F1.20 Drawing descrepancy was RESTRAINT noted. Single nut on top of turnbuckle (2 nuts observed on drawing) and a nut is missing at the bottom of the turnbuckle (1 nut observed on drawing). Engineering Disposition: Use as-is. A CRN-C-11336 (PC/M 030106) and MRA CR 04-10091 for SPEC C-024 will be issued.
Reference CR 2004-10091.
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 40 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 2 CBEAR COMPONENTS STEAM GENERATOR A BLOWDOWN INSIDE CONTAINMENT J-.LJ ASME _ASUS N I 0 SEC. XI O N GT R S EH REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I OE NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G MR **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-795-S SH. 2) 313500 61-BDA-2301-1 C-F-2 C MT 2.2-002 X - - - 10/15/2004 - MT complete.
REDUCER TO VALVE C5.51 UT 5.2-001 - - - - No Recordable Indications.
45S2.25AX - - X - 10/16/2004 - UT complete.
SGB-3-001 45S2.25CIR Root geometry recorded.
- UT-22**
313900 78101B-H-320-09 F-A C VT-3 4.3-037 X - - - 10/13/2004 - VT-3 complete.
DOUBLE ACTING P1.20 No Recordable Indications.
RESTRAINT 313950 78101B-H-320-09 IA C-C C MT 2.2-002 X - - - 10/15/2004 - MT complete.
INTEGRAL ATTACHMENTS C3.20 No Recordable Indications 314200 60-BDA-2301-5 C-F-2 C MT 2.2-002 X - - - 10/15/2004 - MT complete.
REDUCER TO VALVE C5.51 UT 5.2-001 - - - - No Recordable Indications.
SGB-3-002 45S2.25AX - - X - 10/16/2004 - UT complete.
4SS2.25CIR X - - -
Root geometry recorded.
- UT-22**
314300 61-BDA-2301-6 C-F-2 C MT 2.2-002 X - - - 10/1S/2004 - MT complete.
VALVE SGB-3-002 TO C5.51 UT 5.2-001 - - - - No Recordable Indications.
ELBOW 45S2.25AX X - - - 10/16/2004 - UT complete.
4552.25C1R X - - -
No Recordable Indications.
- UT-22**
314700 6--BDA-2301-8 C-F-2 C MT 2.2-002 X - - - 10/15/2004 - MT complete.
PIPE TO TEE C5.51 UT 5.2-001 - - - - No Recordable Indications.
45S2.25AX X - - - 10/16/2004 - UT complete.
45S2.2SCIR X - - -
70S2.25AX - - X - Root geometry recorded.
- UT-22**
____________________GNO.____----_______________S_______________._______________________)______
(REP. DWG. NO. S613-P-79S-S SH. 1)
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 41 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 2 CBEAR COMPONENTS STEAM GENERATOR A BLOWDOWN INSIDE CONTAINMENT 3-103 ASME NI 0 SEC. XI ON G T R S E H
SUMMARY
EXAMINATION AREA CATEGY EXAM EI 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # CG M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-795-S SH. 1) 316300 6'-BDA-2301-18 C-F-2 C MT 2.2-001 X - - - 10/14/2004 - MT complete.
PIPE TO ELBOW C5.51 UT 5.2-001 - X - No Recordable Indications.
4552.25AX I 10/16/2004 - UT complete.
4552.25CIR x 7052.25AX - X _ Root geometry recorded.
Informational radiograph was shot in the introdose of the elbow due to as welded condition not allowing a UT profile for 70 degree indication. Root geometry seen only. **UT-22**
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 42 REVISION: 0 INSERVICE INSPECTION RESULTS SUvMMARY INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 2 CBEAR COMPONENTS STEAM GENERATOR C BLOWDOWN INSIDE CONTAINMENT 3-105 A C^ N I 0 SEC. XI O N G T R S E H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-797-S SH. 1) 322800 78101B-H-322-02 F-A C VT-3 4.3-035 X - - - 10/10/2004 - VT-3 complete.
DOUBLE ACTING F1.20 No Recordable Indications.
RESTRAINT
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 43 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 2 CBEAR COMPONENTS MAIN FEEDWATER SYSTEM LOOP A 3-109 ASME TATUS N I 0 SEC. XI ON G T R SE H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I O E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C GM R *"CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-651-S SH. 1) 330500 AUGMENTED EXAMINATION AUG A UT 5.16-001 - - - - 10/13/2004 - UT complete.
FROM NOZZLE RAMP TO 1 60S2.25AX - - X X Previously recorded root 60S5.OAX X - - - geometry and non-metallic DIAMETER ON ELBOW 70S2.25AX K - - -
70S5.0AX X - - - inclusions verified by 0 degree observed. **UT-20, UT-29**
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 44 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 2 CBEAR COMPONENTS MAIN FEEDWATER SYSTEM LOOP B 3-110 ASME _STATUS N I 0 SEC. XI O N 0 T R SE H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C GM R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-652-S SH. 1) 333800 AUGMENTED EXAMINATION AUG A UT 5.16-002 - - - - 10/13/2004 - UT complete.
FROM NOZZLE RAMP TO 1 60S2.25AX - - X - Previously recorded root 60S5.0AX DIAMETER ON ELBOW - - K - geometry and backing ring 70S2.25AX 70S5.0AX - - X - observed. **UT-20, UT-29**
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 45 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 2 CBEAR COMPONENTS MAIN FEEDWATER SYSTEM LOOP C 3-111 ASME _STATUS NI 0 SEC. XI ON G S R S E H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM EI 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-178-S SE. 1) 338200 AUGMENTED EXAMINATION AUG A UT 5.16-003 - - - - 10/13/2004 - UT complete.
FROM NOZZLE RAMP TO 1 60S2.25AX - - X - Previously recorded root 6055.OAX DIAMETER ON ELBOW - - X - geometry and backing ring 70S2.25AX 7055.OAX - - x - observed. **UT-20, UT-29--
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 46 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 3 CBEAR COMPONENTS COMPONENT COOLING WATER SYSTEM INSIDE CONTAINMENT 3-118 1ASME N I 0 SEC. XI O N G T R S E E REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I O E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-628-S SE. 1) 344920 3-ACH-93 F-A C VT-3 4.3-027 X - - - 10/03/2004 - VT-3 complete.
DOUBLE ACTING P1.30 No Recordable Indications.
RESTRAINT
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 47 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 3 CBEAR COMPONENTS COMPONENT COOLING WATER SYSTEM FROM CCW PUMP C 3-120 ASM NI 0
_ATXUY SEC. XI ON G T R S E H REMAR2S
SUMMARY
EXAMINATION AREA CATEGY EXAM EI O E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-596-S SH. 1) 345600 3-ARH-91 F-A C VT-3 4.3-024 X - - - 10/03/2004 - VT-3 complete.
SINGLE ACTING F1.30 No Recordable Indications.
RESTRAINT
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 48 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 3 CBEAR COMPONENTS COMPONENT COOLING WATER PROM NORMAL CONT. COOLER D 3-123 X N I 0 SEC. XI ON G T R S E REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET# C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-630-S SH. 1) 348200 3-CCH-1 F-A R VT-3 NDE 4.3 DOUBLE ACTING F1.30 RESTRAINT
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 49 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 3 CBEAR COMPONENTS COMPONENT COOLING WATER SYSTEM OUTSIDE CONTAINMENT 3-138 ASME -STATUS N I 0 SEC. XI O N U T R S E H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R *CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-603-S SH. 1) 356500 SR-299 F-A C VT-3 4.3-025 X - - - 10/03/2004 - VT-3 complete.
DOUBLE ACTING F1.30 No Recordable Indications.
RESTRAINT 356550 SR-299 IA D-A C VT-1 4.1-005 X - - - 10/03/2004 - VT-1 complete.
INTEGRAL ATTACHMENTS Dl.20 No Recordable Indications
DATEt 02/15/05 TURKEY POINT - UNIT 3 PAGEs 50 REVISIONs 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 3 CBEAR COMPONENTS COMPONENT COOLING WATER TO SPENT FUEL PIT HX 3 -. L U _STATUS N I 0 ASME SEC. XI ON G T R SE H
SUMMARY
EXAMINATION AREA CATEGY EXAM E I0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C GM R **CALIBRATION BLOCK"*
(REF. DWO. NO. 5613-P-623-S SH. 1) 357750 SPENT FUEL PIT UT EXCH F-A C VT-3 4.3-011 X - - - 10/03/2004 - VT-3 complete.
HEAT EXCHANGER SUPPORT PF. 40 No Recordable Indications.
357760 SPENT FUEL PIT HT EXCH D-A C VT-1 4.1-002 X - - - 10/03/2004 - VT-1 complete.
INTEGRAL ATTACHMENT D1.10 No Recordable Indications
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 51 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 3 CBEAR COMPONENTS COMPONENT COOLING WATER SYSTEM OUTSIDE CONTAINMENT 3-149 ASME --- N I 0 SEC. XI ON G T R SE H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C GM R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-614-S SH. 1) 361900 8074-H-327-01 P-A C VT-3 4.3-023 X - - - 10/03/2004 - VT-3 complete.
DOUBLE ACTING F1.30 No Recordable Indications.
RESTRAINT
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 52 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 3 CBEAR COMPONENTS COMPONENT COOLING WATER SYSTEM OUTSIDE CONTAINMENT 3-151 -- N I 0 1 -HTATUS SEC. XI O NG T R SE H
SUMMARY
EXAMINATION AREA CATEGY EXAM E I0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEETS# C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-614-S SH. 2) 363800 SR-172 F-A C VT-3 4.3-022 X - - - 10/03/2004 - VT-3 complete.
DOUBLE ACTING F1.30 No Recordable Indicationa.
RESTRAINT
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 53 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 3 CBEAR COMPONENTS COMPONENT COOLING WATER PROM RHR HEAT EXCHANGER A 3-153 ASME . N I 0 SEC. XI O NG T R SE H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E 1 OE NUMBER IDENTIFICATION ITEM NO METBOD DATA SHEET # C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-612-S SH. 2) 365900 3-ACH-2 F-A C VT-3 4.3-038 X - - - 10/04/2004 - VT-3 complete.
SINGLE ACTING F1.30 No Recordable Indications.
RESTRAINT
DATE: 02/15/05 TURK.EY POINT - UNIT 3 PAGE: 54 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 3 CBEAR COMPONENTS COMPONENT COOLING WATER SYSTEM OUTSIDE CONTAINMENT 3-156 a?" --- N I 0 1-
_TATUS SEC. XI ON G T RS E E REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I0 E NUMBER IDENTIFICATION ITEM NO METBOD DATA SHEET # C GM R **CALIBRATION BLOCK" (REF. DWG. NO. 5613-P-614-S SH. 3) 367200 SR-145 F-A C VT-3 4.3-021 X - - - 10/03/2004 - VT-3 complete.
ANCHOR F1.30 No Recordable Indications.
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 55 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4. PERIOD 1, OUTAGE 1 (04)
CLASS 3 CBEAR COMPONENTS COMPONENT COOLING WATER SYSTEM TO CCW PUMPS A & B 3-157 ASME TATUS N I 0 SEC. XI _ O N G T R S E H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-614-S SH. 3) 367840 CCW PUMP 3P211A F-A C VT-3 4.3-020 X - - - 10/03/2004 - VT-3 complete.
PUMP SUPPORT F1.40 No Recordable Indications.
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 56 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 3 CBEAR COMPONENTS COMPONENT COOLING WATER SYSTEM OUTSIDE CONTAINMENT 3-158 ASM N I 0 SEC. XI ON 0 T R SE H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I OE NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C GM R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-614-S SH. 2) 368400 SR-142 F-A C VT-3 4.3-004 X 10/3/2004 - VT-3 complete.
DOUBLE ACTING F1.30 Field verified clearances RESTRAINT differ from drawing. Actual field clearances are 01 on west side of restraint and 3/16- on east side of restraint. Engineering Disposition: Use as-is.
Gap is acceptable per the SSD-C-011. Reference CR 2004-10092.
DATE: 02/15/05 TURXEY POINT - UNIT 3 PAGE: 57 INSERVICE INSPECTION RESULTS
SUMMARY
REVISION: 0 INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 3 CBEAR COMPONENTS COMPONENT COOLING WATER FROM NON-REGENERATIVE EX 3-161 C 1AM N I 0 SEC. XI O N G T R S E E REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I 0 E NUMBER IDENTIFICATION ITEM NO METEOD DATA SHEET # C G M R **CALIBRATION BLOCK*"
(REF. DWG. NO. 5613-P-622-S SE. 2) 370550 3-ACE-158 F-A C VT-3 4.3-013 X - - - 10/03/2004 - VT-3 complete.
DOUBLE ACTING F1.30 No Recordable Indications.
RESTRAINT
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 58 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 3 C8EAR COMPONENTS AUXILIARY FEEDWATER SYSTEM PUMP DISCHARGE 3-162 ASME NI 0 W
SAT US SEC. XI ON G T R S E H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM EI 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5610-P-884-S SH. 5) 371600 80117-H-322-07 F-A C VT-3 4.3-031 X - - - 10/04/2004 - VT-3 complete.
DOUBLE ACTING F1.30 No Recordable Indications.
RESTRAINT 371700 80117-H-322-07 IA D-A C VT-1 4.1-011 X - - - 10/04/2004 - VT-1 complete.
INTEGRAL ATTACHMENT D1.20 No Recordable Indications.
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 59 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 3 CBEAR COMPONENTS INTAKE & CHLOR.WATER FROM INTAKE COOLING WTR.PUMPS 3-167 Arov N I 0 WALUb SEC. XI O N G T R S E H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXA M E I O E NUMBER IDENTIFICATION ITEM NO METS HOD DATA SHEET # C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-606-S SH. 1) 377600 M-196-1 F-A A VT-3 4.3-044 X - - - 10/24/04 - VT-3 Complete.
SINGLE ACTING F1.30 No Recordable Indications.
RESTRAINT Examination performed per MRA-31007526-05. Modified support for easy access.
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 60 REVISION: 0 INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 3 CBEAR COMPONENTS INTAKE COOLING WATER TO CCW HEAT EXCHANGERS 3-168 ASME - N I 0 SEC. XI ON GT R S E H REMARKS
SUMMARY
EXAMINATION AREA CATEGY EXAM E I OE NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET P C G MR **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-633-S SH. 1) 378750 STRAINER B F-A C VT-3 4.3-002 - - - X 10/03/2004 - VT-3 complete.
WELDED STANCHION F1.40 Reported an 8" crack in the concrete at the southwest corner of the support.
Engineering Disposition -
Use as is. Reference CR 2004-10090.
378760 STRAINER B IA D-A C VT-1 4.1-001 X - - - 10/03/2004 - VT-1 complete.
INTEGRAL ATTACHMENTS Dl.10 No Recordable Indications
DATE: 02/15/05 TURKEY POINT - UNIT 3 PAGE: 61 REVISION: INSERVICE INSPECTION RESULTS
SUMMARY
INTERVAL 4, PERIOD 1, OUTAGE 1 (04)
CLASS 3 CBEAR COMPONENTS INTAXE COOLING WATER TO CCW BEAT EXCHANGERS
.3-16 ASME _STATUS N I 0 SEC. XI O N G T R S E H
SUMMARY
EXAMINATION AREA CATEGY EXAM E I 0 E REMARXS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK**
(REF. DWG. NO. 5613-P-820-S SH. 2) 378900 8045-H-172-01 F-A C VT-3 4.3-018 X - - - 10/03/2004 - VT-3 complete.
SINGLE ACTING F1.30 No Recordable Indications.
RESTRAINT 379280 8045-H-172-05 F-A C VT-3 4.3-019 X - - - 10/03/2004 - VT-3 complete.
SINGLE ACTING Fl.30 No Recordable Indications.
RESTRAINT
I : - .
TURKEY POINT UNIT 3 2004 REFUELING OUTAGE NIS-BB Report
I
- IN
. .;-;A'."iFORM NIS:BB OWNERSWAT&REPIORt iR EDbY+CUMENT"E)Am1NAtJON RESULTS '
A (iR:,qiredrb MER LE-Sj i 2 ZA ON L-kf;~
PLANT: Turkey Point Unit 3 EXAMINATION DATE: October 5,2004 to October 14, 2004 :
TOTAL TOTAL TOTAL TUBES TUBES TOTAL STEAM TUBES TUBES I TUBES PhEVENTIVELY PLUGGED PLUGGED GENERATOR INSPECTED 20%-39% 2 40%, PIT & VOL PWGGED (PTP) THIS TUBES
- :: OUTAGE IN S/G 3E210A (Bobbin) 3167 .0 .0 0 See RPC 3E210B (Bobbin) 3145 30 0 0 See RPC 3E210C (Bobbin) 3161 16(11 0 0 0 See RPC 3E210A (RPC) 3167p) 0 0 0 0 47 3E210B (RPC) 3145p) 0 0 0 0 69 3E210C (RPC) 31613) 0 0 0 0 53 LOCATION OF INDICATIONS (20% - 100% PIT & VOL. WARPLP. SVI)
Tube Tube Freespan Top of Top of Total Total STEAM AVB Supports Supports 6H thu 6C Tubesheet Tubesheet Indications Indications GENERATOR Bars 1 thru 6 1 Ihru 6 UBEND to #1 to #1 20%-39% 2a40%. PIT C/L: FM Support C/L Suport L &VOL 3E210A (Bobbin) 3m 0 0 0 0 0 30 ° 6
3E210B (Bobbin) m= 0 0 0 0 0 60n 22 3E210C (Bobbin) 5t) 0 0 0 0 0 22Xt 0 3E210A(RPC) 0 0 0 0 0 0 0 0 3E210B (RPC) 0 0 0 0 0 0 0 £0 3E210C (RPC) 0 0 0 0 0 . 0 0 LOCATION OF INDICATIONS (1%-19%)
Tube Tube Freespan Top of Top of Total Total STEAM AVB Supports Supports 6H thru 60 Tubesheet Tubesheet Indications Indications GENERATOR Bars 1thr 6 1 lthru6 UBEND to #1 to #1 1%-19% 1%-39%
CIL UL . Support CAI Support HIL Left In
._ Service 3E210A (Bobbin) 14 nIl 0 0 0 0 0 See RPC See RPC 3E210B (Bobbin) 24 _ O 0 0 0 See RPC See RPC 67 3E210C (Bobbin) ) 0 0 0 0 0 See RPC See RPC 2
3E210A (RPC) 0 0 *tl 0 1m 102) 17mm 0Vnm 26 3E210B (RPC) 0 m tm 0 0 0 riym 32rlM2 69 9 3E210C (RPC) 0 0 .1a zM O 1a, 0 C1IX 1nx2_
Remarks:
- 1. Mechanical wear damage at anti-vibration bars (AVB) was depth sized (zslng qualified bobbin coil sizing technique.
- 2. Mechanical wear damage at ocations other than ant-vbatlon bars (AVB) was depth sized using qualnfed Plus Point- rotating coil sizing technique.
- 3. Inrludes tubes In the dent, low row U-bend, hot leg and cold leg tubesheet expansIon transition programs.