L-2012-435, Inservice Inspection Program Fourth Interval-Third Period-First Refueling Outage Owner'S Activity Report (OAR-1)

From kanterella
Jump to navigation Jump to search
Inservice Inspection Program Fourth Interval-Third Period-First Refueling Outage Owner'S Activity Report (OAR-1)
ML12348A395
Person / Time
Site: Turkey Point NextEra Energy icon.png
Issue date: 12/03/2012
From: Kiley M
Florida Power & Light Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-2012-435
Download: ML12348A395 (4)


Text

0 FPL.

DEC 0 3 2012-L-2012-435 10 CFR 50.55a U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C. 20555-00001 Re: Turkey Point Unit 3 Docket No. 50-250 Inservice Inspection Program Fourth Interval-Third Period-First Refueling Outage Owner's Activity Report (OAR-i)

Attached find the Owner's Activity Report (Form OAR-i), for Turkey Point Unit 3 Fourth Inservice Inspection Interval, Third Period, First Refueling Outage (PTN 3-26). The Form OAR-I, Owner's Activity Report, implements Code Case N-532-4.

Should there be any questions concerning this report, please contact Robert J. Tomonto at 305-246-7327.

Vice President Turkey Point Nuclear Plant SM Attachment Florida Power & Light Company 9760 S.W. 344 Street Homestead, FL 33035 Au4-T

L-2012-435, Attachment FORM OAR-1 OWNER'S ACTIVITY REPORT Report Number: ISI-PTN-3-2012 Plant: Turkey Point Nuclear Power Plant Unit 3 9760 SW 344th Street Homestead, Florida 33035 Commercial Service Date: December 14, 1972 Refueling Outage No.: PTN 3-26 Current Inspection Interval: ISI-Fourth IWE-Second IWL Second Current Inspection Period: ISI-Third IWE-Second IWL - 40th Year Edition and Addenda of Section XI applicable to the inspection plans: ISI-1 998 Edition with Addenda through 2000 and IWE & IWL -2001 with Addenda through 2003.

Date and Revision of inspection plans: ISI-July 23, 2010 Rev. 3 IWE-March 3, 2009, Rev.0 IWL - November 2010 Rev. 0 Edition and Addenda of Section XI applicable to repairs and replacements, if different than the inspection plan: Same Code Cases Used: N-460, N-532-4, N-533-1, N-566-1, N-616, N-623, N-624, N-658, N-686, N-722-1 CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in this report are correct: (b) the examinations and tests meet the Inspection plan as required by the ASME Code, Section Xl; and (c) the repair/replacement activities and evaluations supporting the completion of PTN 3-26 conform to the requirements of Section XI.

Signed -- " A.. D "z *, "i_ .Owner or O'wner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors, and the State or Province of Florida and employed by HSBCT of Hartford Connecticut have inspected the items described in this Owner's Activity Report, and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair/replacement activities and evaluation described in this report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

,/--< . ./( Commissions fZ //- ,.oev 6 d 4 (4,.cC, AJ,*)

Inspector's Signature National Board, State. Province, and Endorsements Date Page 1 of 3

L-2012-435, Attachment FORM OAR-1 OWNER'S ACTIVITY REPORT TABLE 1 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE Examination Category and Item Description Evaluation Description Item Number B-B/B2.11 Pressurizer Circumferential Weld Evaluate for slag inclusions in weld.

Acceptable for continued service Evaluate for missed final NDE during D-AD1 .20 Welded Attachment installation of new support.

Acceptable for continued service until next cycle.

Page 2 of 3

L-2012-435, Attachment FORM OAR-1 OWNER'S ACTIVITY REPORT TABLE 2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Code Class Item Description Date Repair/Replacement Description Of Work Completed Plan Number 1 Reactor Head Replace 8/12/12 RR40034260-01 Nuts 1 Heat Exchanger Repair gouges in 8/12/12 RR39010145-05 channel head Cut out for 1 Piping and license renewal 8/12/12 RR40152465-01 fittings commitment for testing Replace due to 2 Piping and lowfrom readings wallinternal 6/22/12 RR40047871-01 Elbow corrosion Spring Can Swap spring cans to proper 11/15/12 RR40068968-95 Support configuration Condensate R 3 Storage +Tank eplace ont 3/11/12 RR40011000-03 Vent Piping piping on tank Page 3 of 3