Structural Integrity Associates Engineering Report No. 0901350.304, Revision 3, Fatigue Crack Growth Evaluation, October 12, 2018
ML18299A118
Person / Time
Site: Turkey Point  NextEra Energy icon.png
Issue date: 10/12/2018
From: Fong M, Shim D
Structural Integrity Associates
To:
Florida Power & Light Co, Office of Nuclear Reactor Regulation
References
L-2018-174 0901350.304, Rev 3
Download: ML18299A118 (73)


Text

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 FPL Response to NRG RAI No. 4.7.4-3 L-2018-174Attachment 19 Enclosure 1 Page 1 of73 Structural Integrity Associates Engineering Report No. 0901350.304, Revision 3, "Fatigue Crack Growth Evaluation," October 12, 2018

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 I)

Structural Integrity Associates, Inc.

CALCULATION PACKAGE PROJECT NAME:

Turkey Point 3 and 4 TLAA Support for SLR CONTRACT NO.:

2000230248 L-2018-174 Attachment 19 Enclosure 1 Page 2 of 73 File No.: 0901350.304 Project No.: 1700109 Quality Program: ~ Nuclear D Commercial CLIENT:

CLIENT:

Florida Power & Light (FPL)

Florida Power & Light (FPL)

CALCULATION TITLE:

Fatigue Crack Growth Evaluation Document Affected Project Manager Revision Pages Revision Description Approval Signature & Date 0

1 - 23 Initial Issue Art McSherry Al-A24 4/15/10 Computer Files 1

1 - 20 Updated 60-year results in Gary Stevens Al-A52 response to CAR 17-012.

7/10/17 Computer Files Extended evaluation to cover 80 years of operation and to use updated fatigue crack growth law.

2 5, 6, 9, 11, 14 Addressed client editorial Gary Stevens comments 9/18/17 3

1-9, 11, Updated through-wall ~~

14 - 20, crack growth calculation.

A-47 -A-52 Remove proprietary source of design input.

David A. Gerber 10/12/18 Preparer(s) &

Checker(s)

Signatures & Date Peihua Jing 4/15/10 Haiyang Qian 4/15/10 Wilson Wong 7/10/17 DJ Shim 7/10/17 Wilson Wong 9/18/17 DJ Shim 9/18/17

~ ~

Minji Fong 10/12/18

~

Do Jun Shim 10/12/18 Page 1 of21 F0306-01R2

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 L-2018-174 Attachment 19 Enclosure 1 Page 3 of73 e

Structural Integrity Associates, Inc.

Table of Contents 1.0 OBJECTIVE.................................................................................................................. 4 2.0 METHODOLOGY........................................................................................................ 4 3.0 CALCULATIONS......................................................................................................... 5 3.1 Plant Design Transients............................................................................................. 5 3.2 Stresses...................................................................................................................... 7

3. 2.1 Internal Pressure............................................................................................... 8 3.2.2 Thermal Expansion............................................................................................ 8 3.2.3 Dead Weight...................................................................................................... 9 3.2.4 Residual Stress................................................................................................. 11 3.2.5 Seismic Loads.................................................................................................. 11 3.2.6 Stress Ranges................................................................................................... 11 3.3 Allowable Flaw Size............................................................................................... 14 3.4 Fatigue Crack Growth Analysis.............................................................................. 14 3.4.1 Fatigue Crack Growth Law Usedfor 60-Year Operation Calculations......... 14 3.4.2 Fatigue Crack Growth Law Used for 80-Year Operation Calculations......... 15 3.4.3 Part Through-Wall Crack Growth................................................................... 16 3.4.4 Through-Wall Crack Growth........................................................................... 16 4.0 RESULTS.................................................................................................................... 11*

5.0 REFERENCES

............................................................................................................ 20 APPENDIX A PC-CRACK OUTPUT................................................................................. A-1 A.l ACCUMULATOR LINE 60 YEARS...................................................................... A-2 A.2 ACCUMULATOR LINE 80 YEARS...................................................................... A-7 A.3 RHR LINE 60 YEARS........................................................................................... A-13 A.4 RHR LINE 80 YEARS........................................................................................... A-19 A.5 SURGE LINE 60 YEARS...................................................................................... A-26 A.6 SURGE LINE 80 YEARS...................................................................................... A-37 A. 7 ACCUMULATOR LINE THROUGH-WALL CRACK STRESS INTENSITY CALCULATION.................................................................................................... A-47 A.8 RHRLINE THROUGH-WALL CRACK STRESS INTENSITY CALCULATION.................................................................................................. A-49 A.9 SURGE LINE THROUGH-WALL CRACK STRESS INTENSITY CALCULATION................................................................................................... A-51 File No.: 0901350.304 Revision: 3 Page 2 of20 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

List of Tables L-2018-174 Attachment 19 Enclosure 1 Page 4 of73 Table 3-1: Accumulator Line Operating Condition Transients................................................ 5 Table 3-2: RHR Line Operating Condition Transients............................................................. 6 Table 3-3: Surge Line Operating Condition Transients........................................................... 7 Table 3-4: Pipe Geometry Inputs.............................................................................................. 8 Table 3-5: Operating Conditions..................................................... :........................................ 8 Table 3-6: Piping Loads for Accumulator and RHR Lines...................................................... 9 Table 3-7: Accumulator Line Maximum and Minimum Transient Stresses.......................... 10 Table 3-8: RHR Line Maximum and Minimum Transient Stresses....................................... 10 Table 3-9: Stress Ranges for Accumulator Line..................................................................... 12 Table 3-10: Stress Ranges for RHR Line............................................................................... 12 Table 3-11: Stress Ranges for Surge Line.............................................................................. 13 Table 4-1: Fatigue Crack Growth Results for Part Through-Wall Flaws............................... 17 Table 4-2: Fatigue Crack Growth Results for Through-Wall Flaws...................................... 19 File No.: 0901350.304 Revision: 3 Page 3 of20 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

1.0 OBJECTIVE L-2018-174 Attachment 19 Enclosure 1 Page 5 of73 This calculation package documents the analysis performed to study the fatigue crack growth of cracks in 5 auxiliary lines at the Turkey Point Nuclear Plant (PTN), Units 3 and 4 as part of the leak-before-break evaluation (LBB) of these lines. The auxiliary lines of interest are pipes attached to the primary reactor coolant loop (RCL) piping, shown as follows:

1. 10-inch diameter accumulator lines - 3 lines ( one per RCL)
2. 12-inch pressurizer surge line - I line attached to "B" loop
3. 14-inch residual heat removal (RHR) line-1 line attached to "C" loop in Unit 3 and "A" loop in Unit 4 The first objective of this analysis is to show that a postulated circumferential partial through-wall crack (PTWC) of ASME B&PV Code [1], IWB-3514 allowable depth for stainless steel (up to 12.5% of wall thickness) does not grow significantly between in-service inspection (ISI) intervals. The second purpose of this analysis is to demonstrate that iflarger PTWCs exist they would tend to grow in the depth direction and through the pipe wall before extending significantly in length ( circumferentially) to cause double guillotine break failure, thus exhibiting leak-before-break behavior. The third purpose of this analysis is to show that the through-wall crack is stable during an SSE event per NUREG-1061, Section 5.2 (g) [9].

In Revision 1 of the calculation, the previous fatigue crack growth evaluation for 60 years is updated to use the current version of the pc-CRACK software (pc-CRACK 4.1 [8a]) and to correct for the errors documented in Corrective Action Report (CAR)17-012 [15]. Also, fatigue crack growth for 80 years of operation is added to address Subsequent License Renewal (SLR) operation utilizing the updated ASME Code Case N-809 [6] fatigue crack growth rate.

In Revision 3 of the calculation, fatigue crack growth for the through-wall flaw is updated and the results are compared with the critical flaw size.

2.0 METHODOLOGY The fatigue crack growth calculations are performed with the following tasks:

a.

Calculate the total stresses range for each transient category including deadweight stresses.

b.

Use the ASME Section XI fatigue crack growth law [1] for austenitic stainless steels (for 60 years) and use the ASME Code Case N-809 [6] fatigue crack growth law (for 80 years) to perform crack growth analysis by applying the appropriate scaling factors to the reference K for the transient stresses.

Note that for Surge line, the stress range is given as design input, thus Step "a" is skipped.

File No.: 0901350.304 Revision: 3 Page 4 of20 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 L-2018-174 Attachment 19 Enclosure 1 Page 6 of 73 e

Structural Integrity Associates, Inc.

3.0 CALCULATIONS 3.1 Plant Design Transients Since the auxiliary lines at PTN were designed to the requirements of ANSI B3 l. l, no line specific transients are defined or analyzed in the design basis report. Hence, transient information from a generic U. S Pressurized Water Reactor (PWR) Operational Transients report [2] is obtained to perform the crack growth evaluation. The plant transients affecting crack growth of the auxiliary lines of PTN Units 3 and 4, provided in Reference [2], are presented in Table 3-1 for the Accumulator Line and in Table 3-2 for the Residual Heat Removal Line.

In addition, the Surge Line experiences thermal stratification which results in a larger stress range, thus more fatigue growth during transients. A Westinghouse fatigue calculation [4] was conducted considering the thermal stratification during the transients. The defmition of transients for crack growth, number of cycles, as well as the stress range for each transient are obtained from this calculation and reproduced in Table 3-3.

Notes:

Table 3-1: Accumulator Line Operating Condition Transients Transient Design Transients Occurrences<1l Af(6)

AT (psi)

{°F) 1 2

3 4

Inadvertent RCS Depressurization 20<2>

1,117 490(3)

Inadvertent Accumulator Blowdown 4(4) 232 330<4)

Post LOCA Operation 1 (4) 1,117 490<3)

OBE 50(7) 0 0

1. The above event counts reflect the 40-year design life, which is applicable to both 60 years and 80 years of operation per References [12 and 13].
2. Obtained from Reference [2].
3. Assumed as the temperature difference between typical cold leg temperature of 560°F and room temperature of70°F.
4. Assumed based on similar plant design data [3, Table 4.3-2].
5. Assumed as the temperature difference between temperature of 400°F and room temperature of 70°F.
6. Conservatively calculated as the pressure difference between the saturated steam pressure at high temperature and ambient pressure.
7. Assumed the same as in Surge Line [ 4].

File No.: 0901350.304 Revision: 3 Page 5 of20 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 L-2018-174 Attachment 19 Enclosure 1 Page 7 of73 e

Structural Integrity Associates, Inc.

Table 3-2: RHR Line Operating Condition Transients Transient Design Transients Occurrences<2>

Af>

AT (psi)

{°F) 1 Heat Up /Cooldown 200 each 1925 437 2

Unit Load/Unload at 500 each 0(3) 9.6 15% Full power 3

Unit Load /Unload at 13,200 68(3) 55 5% Full power 4

Step Load Increase/Decrease of 2,000 each 109<3) 8.7 10% Full power 5

Reactor Trip with Cooldown and 10 539 139 Safety Injection 800 0

6 200 Primary Side Leakage Test (Assumed)

(Assumed) 7 Notes:

OBE 50<4)

  • o 0
1. Above transients are obtained from Reference [2]..
2. The above event counts reflect the 40-year design life, which is applicable to both 60 years and 80 years of operation per References [12 and 13].
3. Conservatively assumed based on similar plant operational data.
4. Assumed the same as in Surge Line [ 4].

File No.: 0901350.304 Revision: 3 Page 6 of20 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

L-2018-174 Attachment 19 Enclosure 1 Page 8 of73 Table 3-3: Surge Line Operating Condition Transients Occurrences<1>

Max Stress<3>

Min Stress<3>

Transient#

Design Transients (ksi)

(ksi) 1 Heatup 200<2) 10.158

-8.179 2

Unit Loading 13,200<2>

14.583 11.150 3

Step Load Increase and Decrease 4000 15.465 9.599 4

Large Step Load Decrease with Steam Dump 200 14.470 9.430 5

SS Fluctuation 3,150,000 12.232 10.895 6

Loss of Load 80 18.677 9.340 7

Loss of Power 40 17.259 9.449 8

Loss of Flow 80 14.286 9.299 9

Reactor Trip 400 15.963 2.654 10 Inadvertent Auxiliary Spray 10 15.045 11.108 11 OBE 50 15.735 3.972 12 Unit Unloading 13,200<2) 14.583(4) 11.150<4) 13 Cool Down 200<2>

10.158

-8.179 14 Turbine Roll Test 10 2.292 0.000 15 Hydrotest@ 3,107 psi 5

9.858 0.000 16 Leak Test@ 2,485 psi 50 8.145 0.000 Notes:

1. The above event counts reflect the 40-year design life, which is applicable to both 60 years and 80 years of operation per References [12 and 13].
2. Obtained from Reference [2].
3. Stress values are obtained from Table 8 of Reference [4].
4. Values are assumed the same as Unit Loading transient.

3.2 Stresses Axial stresses in the auxiliary lines need to be determined since circumferential flaws are postulated for the LBB evaluation. For Surge Line, the stress range are documented in Reference [ 4] and given in Table 3-3. For Accumulator and RHR Lines, the axial stress due to the pressure, deadweight, thermal differentials for each of the transient as well as the seismic loads are calculated using the respective moments. Section 3.2.1 through Section 3.2.5 show the methodology of calculating stress range for Accumulator and RHR Lines. The thermal differentials for each transient of these lines are documented in Reference [2] and summarized in Table 3-1 and Table 3-2. The axial stresses due to each of the load categories are calculated by linear factorization as follows.

File No.: 0901350.304 Revision: 3 Page 7 of20 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

3.2.1 Internal Pressure The axial stress due to operating pressure Poper is calculated as 2

Poper Di (J =-----

p (D/ -D/)

L-2018-174 Attachment 19 Enclosure 1 Page 9 of 73 (3-1) where, Do is the outside diameter and Di is the inside diameter of the pipe, obtained from Reference [5]

and reproduced in Table 3-4.

Table 3-4: Pipe Geometry Inputs Accumulator Surge LineO)

RHRLine Line OD,in 10.75 12.75 14.00 Thickness, in 1.00 1.125 1.25 Note: (1) The geometry on the Pipe side of Surge line is conservatively used.

The operating pressure for accumulator lines and RHR lines are obtained from Reference [5] and reproduced in Table 3-5.

Table 3-5: Operating Conditions Accumulator Line Surge Line Surge Line Hot RHRLine Pressurizer End Leg End Temperature, 555 653 610.9 610.9 op Pressure, psig 2,485 2,235 2,235 2,235 For transients that have pressure different than the operating pressure, the axial stress due to pressure is factored by the ratio of the transient pressure range to the operating pressure range:

(3-2)

The pressure range for the transients of Accumulator line and RHR line are obtained from Reference

[2] and reproduced in Table 3-1 and Table 3-2, respectively.

3.2.2 Thermal Expansion The axial stress due to thermal expansion moment can be calculated as:

32MDO CY

= -------=-

TE,oper ll(Do 4 _ D/)

File No.: 0901350.304 Revision: 3 (3-3)

Page 8 of20 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

L-2018-174Attachment 19 Enclosure 1 Page 10 of73 where M is the thermal expansion Moment, Do and Di are the outside diameter and inside diameter of the pipe. Equation (3-3) is derived from the textbook solution of the axial stress due to moment [11]:

Mc CY=--

]

where I= JZ"(D/ - D/), and c = D 0 I 2 [11].

64 (3-4)

Note that the maximum SRSS of thermal moments in x,y,z directions among all the loops in Unit 3 and Unit 4 are chosen, and the resultant moments are given in Table 3-6 for Accumulator Lines and RHR Lines.

For transients that have thermal expansion loads at a temperature other than operating temperature, the axial stress is calculated using Equation (3-3) factored by the ratio of the transient temperature range to the operat1.ng temperature range:

!),_T CY TE,trans = CY TE, aper ~

aper (3-5) where f),_J',,per = l',,per - 70. The operating temperature for accumulator line and RHR line are obtained from Reference [5] and reproduced here in Table 3-5. The temperature range for the transients of Accumulator line and RHR line are obtained from Reference [2] and reproduced in Table 3-1 and Table 3-2, respectively.

Table 3-6: Piping Loads for Accumulator and RHR Lines Dead weight Thermal Moments OBEMoments Components Moments (ft-lb)

(ft-lb)

(ft-lb)

Mx My Mz Mx My Mz Mx My Mz Accumulator 2,847 5,545 25,236 38,919 33,733 26,644 40,607 38,813 17,688 Lines RHRLines 3,574 2,721.

15,696 96,351 88,786 66,018 35,002 52,858 23,458 3.2.3 Dead Weight The Deadweight moments are obtained as the maximum SRSS moments from Loads and Materials calculation package [5] and shown in Table 3-6. The axial stresses due to Deadweight moments are calculated as shown in Equation (3-3), where moment is the SRSS moments in x, y, z directions.

File No.: 0901350.304 Revision: 3 Page 9 of20 F0306-0!Rl

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

L-2018-174 Attachment 19 Enclosure 1 Page 11 of 73 The calculated maximum and minimum axial stresses due to pressure, thermal, and dead weight for each of the plant transients are presented in Table 3-7 for Accumulator line and Table 3-8 for RHR Line.

Table 3-7: Accumulator Line Maximum and Minimum Transient Stresses Maximum Stresses (ksi)

Minimum Stresses (ksi)

Transient Pressure Thermal DW Total Pressure Thermal DW Total 1

2.193 10.169 0.000 0.000 22.838 2.193 33.007 0.000 2

2.648 17.017 1.737 3.320 22.838 2.648 39.856 1.737 3

4.386 20.338 0.000 0.000 22.838 4.386 43.176 0.000 4

4.878 0.000 4.558 19.764(!)

4.878 0.000 4.558

-0.891 (!)

Note: (1) The OBE stress (10.32 ksi) is added to maximum stress and subtracted from minimum stress.

Table 3-8: RHR Line Maximum and Minimum Transient Stresses Transient Maximum Stresses (ksi)

Minimum Stresses (ksi)

Pressure Thermal DW Total Pressure Thermal DW Total 1

3.993 10.810 1.335 16.139 0.000 0.000 1.335 1.335 2

3.993 11.048 1.335 16.376 3.993 10.573 1.335 15.901 3

4.134 12.171 1.335 17.640 3.852 9.450 1.335 J4.637 4

4.220 11.025 1.335 16.580 3.767 10.595 1.335 15.697 5

5.112 14.249 1.335 20.695 2.875 7.372 1.335 11.582 6

5.653 10.810 1.335 17.798 2.334 10.810 1.335 14.479 7

4.637 0

1.335 11.499(1) 4.637 0.000 1.335 0.444(!)

Note: (1) The OBE stress (5.53 ksi) is added to maximum stress and subtracted from minimum stress.

File No.: 0901350.304 Revision: 3 Page 10 of20 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 SJ Structural Integrity Associates, Inc.

3.2.4 Residual Stress L-2018-174 Attachment 19 Enclosure 1 Page 12 of 73 For all the lines including the Surge line, the weld residual stress is conservatively represented by a pure through-wall bending stress equal to the yield stress of the pipe material at the operating temperature. Since Accumulator, RHR and Surge Lines are made of materials of similar type, the most conservative yield strength (Sy) was chosen for all three types of lines. Thus, Sy= 18.28 ksi of Type 316 stainless steel at 653 °F [ 5] is used in the present analyses.

3.2.5 Seismic Loads The number of OBE event occurrences are 50, obtained from Reference [4]. The OBE loads are obtained from Loads and Materials calculation package [5] and reproduced in Table 3-6 for use in part through-wall crack growth analyses. To show that a through-wall crack is stable during an SSE event per NUREG-1061, Section 5.2 (g) [9], 51 cycles of SSE loading (i.e. stress for SSE event) obtained from Reference [14] was used as a conservative input to represent one SSE cycle and 50 cycles of OBE.

3.2.6 Stress Ranges The axial stress due to pressure, thermal, deadweight, seismic, and residual stresses determined above are combined to obtain the stress ranges corresponding to each of the transients identified in Tables 3-1 and Table 3-2 for the Accumulator line and RHR line.

For convenience, the stresses are separated based on their distribution across the thickness of the pipe.

The pressure stresses are taken as uniform stresses whereas the stresses due to the other loads are assumed to vary linearly through the pipe wall.

The computed stress ranges for transients using Table 3-7 and Table 3-8 are presented in Table 3-9 and Table 3-10 for the Accumulator Line and RHR Line, respectively.

The stress range for the Surge Line is derived from Table 3-3. The maximum and minimum stresses in Table 3-3 are axial stress due to pressure and axial stresses due to deadweight, thermal, and seismic moment. The pressure stresses are taken as uniform stresses whereas the stresses due to the other loads are assumed to vary linearly through the pipe wall. For all the transients with no pressure information, the operating pressure of 2,250 psi is conservatively used to calculate the Maximum uniform stress.

The computed stress ranges for transients using Table 3-3 are presented in Table 3-11 for the Surge Line.

File No.: 0901350.304 Revision: 3 Page 11 of20 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

L-2018-174 Attachment 19 Enclosure 1 Page 13 of73 Table 3-9: Stress Ranges for Accumulator Line Cyclic Stresses (ksi)

DW+

Total Stress Ranges (ksi)

Transient Maximum Minimum Residual Maximum Minimum Uniform Linear Uniform Linear (ksi)

Uniform Linear Uniform Linear 1

2.193 10.169 0.000 0.000 22.838 2.193 33.007 0.00 22.838 2

2.648 17.017 1.737 3.320 22.838 2.648 39.856 1.737 26.159 3

4.386 20.338 0.000 0.000 22.838 4.386 43.176 0.000 22.838 4

4.878 10.328.

4.878

-10.328 22.838 4.878 33.166 4.878 12.511 Table 3-10: Stress Ranges for RHR Line Cyclic Stresses (ksi)

Transient Maximum Uniform Linear 1

3.993 10.810 2

3.993 11.048 3

4.134 12.171 4

4.220 11.025 5

5.112 14.249 6

5.653 10.810 7

4.637 5.528 File No.: 0901350.304 Revision: 3 Minimum Uniform Linear 0.000 0.000 3.993 10.573 3.852 9.450 3.767 10.595 2.875 7.372 2.334 10.810 4.637

-5.528 DW+

Total Stress Ranges (ksi)

Residual Maximum Minimum (ksi)

Uniform Linear Uniform Linear 19.615 3.993 30.425 0

19.615 19.615 3.993 30.663 3.993 30.188 19.615 4.134 31.786 3.852 29.065 19.615 4.220 30.641 3.767 30.210 19.615 5.112 33.864 2.875 26.987 19.615 5.653 30.425 2.334 30.425 19.615 4.6365 25.143 4.637 14.087 Page 12 of 20 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 L-2018-174 Attachment 19 Enclosure 1 Page 14 of73 e

Structural Integrity Associates, Inc.

Table 3-11: Stress Ranges for Surge Line Total Stress Ranges (ksi)

Transient#

Maximum Minimum Uniform(!)

Linear Uniform Linear 1

4.742 23.696 0.000 10.101 2

4.742 28.121 0.000 29.430 3

4.742 29.003 0.000 27.879 4

4.742 28.008 0.000 27.710 5

4.784(2) 25.728 4.700C2) 24.475 6

4.742 32.215 0.000 27.620 7

4.742 30.797 0.000 27.729 8

4.742 27.824 0.000 27.579 9

4.742 29.501 0.000 20.934 10 4.742 28.583 0.000 29.388 11 4.742 29.273 0.000 22.252 12 4.742 28.121 0.000 29.430 13 4.742 23.696 0.000 10.101 14 4.742 15.830 0.000 18.280 15 6.548(3) 21.590 0.000 18.280 16 5_23?(4) 21.188 0.000 18.280 Note:

(1) For all the transients with no pressure information, the operating pressure of 2,250 psi is conservatively used to calculate the Maximum uniform stress.

(2) For Transient 5 (steady state fluctuation as shown in Table 3-3), a typical pressure +/-20 psi was added to 2,250 to calculate the maximum and minimum uniform stress (3) The pressure of 3,107 psi, as shown in Table 3-3, is used.

(4) The pressure of2,485 psi, as shown in Table 3-3, is used.

File No.: 0901350.304 Revision: 3 Page 13 of20 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

3.3 Allowable Flaw Size L-2018-174Attachment 19 Enclosure 1 Page 15 of73 At operating temperature, stainless steel material is expected to behave in a ductile manner. Hence, the net section plastic collapse methodology in Appendix C of ASME Code Section XI [1] can be used to determine the allowable flaw size. The load combination used for determining the allowable flaw size is pressure, deadweight, thermal and seismic loads. The flow stress, CTf, for all three types oflines is conservatively assumed as 45.14 ksi-Type 316 at 653°F (Table 5 of Ref. [5)).

For the Accumulator Line, the total stress for this load combination is 19.02 ksi [14]. The stress ratio (crm+CTb)/ crf= 0.42. With an aspect ratio a/1 of 0.1 and a thickness of 1.0 inch, starting with the maximum allowable flaw depth-to-thickness ratio of 0.75, the maximum possible flaw length is 7.5 inches. The ratio of this flaw length to the pipe circumference is 0.22. Using Table C-5310-3 Table C-5310-4 for emergency and faulted conditions, the allowable end-of-evaluation period flaw depth-to-thickness ratio is determined to be 0.75.

For the RHR Line, the total stress for this load combination is 17.38 ksi [14]. The stress ratio (crm+crb)/ CTf= 0.55. With an aspect ratio a/1 ofO.l and a thickness of 1.25 inch, starting with the maximum allowable flaw depth-to-thickness ratio of 0.75, the maximum possible flaw length is 9.34 inches. The ratio of this flaw length to the pipe circumference is 0.22. Using Table C-5310-3 Table C-5310-4 for emergency and faulted conditions, the allowable end-of-evaluation period flaw depth-to-thickness ratio is determined to be 0.70.

For the Surge Line, the total stress for this load combination is 24.73 ksi [14]. The stress ratio

( CTm+CTb)/ CTf = 0.39. With an aspect ratio a/1 of 0.1 and a thickness of 1.125 inch, starting with the maximum allowable flaw depth-to-thickness ratio of 0.75, the maximum possible flaw length is 8.44 inches. The ratio of this flaw lengthJo the pipe circumference is 0.21. Using Table C-5310-3 Table C-5310-4 for emergency and faulted conditions, the allowable end-of-evaluation period flaw depth-to-thickness ratio is determined to be 0.75.

3.4 Fatigue Crack Growth Analysis The fatigue crack growth analysis is performed for the number of cycles corresponding to the 40-year design plant life shown in Section 3.1. These cycles are applicable to both 60 years and 80 years of operation per References [12 and 13]. In the definition of the stress ranges, the stresses are cycled around the sum of deadweight and weld residual stresses, which are always in effect. For each enveloping transient category, the appropriate scaling factors (transient stress/reference stress) are input to obtain the actual K values for the fatigue crack growth.

3.4.1 Fatigue Crack Growth Law Used for 60-Year Operation Calculations Crack growth in stainless steel for 60 years is calculated using the austenitic steel fatigue crack growth law in air from Article C-3210 of the ASME,Section XI [1], shown in Equation 3-6. Reference [7]

indicates a factor of 2 may be applied to Equation 3-6 to account for a PWR environment. This is accounted for in pc-CRACK 4.1 by doubling the number of cycles. For through-wall crack growth File No.: 0901350.304 Revision: 3 Page 14 of20 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 L-2018-174 Attachment 19 Enclosure 1 Page 16 of 73

(> Structural Integrity Associates, Inc.

calculation, the factor of 2 is directly multiplied to the crack growth rate to account for the PWR environment.

where:

da/dN Co C

s T

R t1K n

( da/dN) air= Co(AfZt, units of inch/cycle (3-6)

= crack growth per cycle, a is the crack depth, N is the number of cycles

= C*S

= 101'[-10.009 + 8.12xI04 T-1.l3 xI0-6T2 + 1.02 xI0-9T3]

= 1.0 when R :'S 0

= 1.0 + l.8R when O < R :'S 0.79

= -43.35 + 57.97R when 0.79 < R < 1.0

= metal temperature, °F (taken as the maximum during the transient)

= R-ratio = (KminlK.max)

= Kmax - Kmin = range of stress intensity factor, ksi-in°5

= 3.3 per Section XI, Appendix C [1]

Note that for negative R-ratios (Kmin < 0 and Kmax > 0), the "S" value is 1.0, which could lead to over conservative crack growth for the stainless steel weld. The max Co and thus most conservative growth rate is used for each transient considered.

3.4.2 Fatigue Crack Growth Law Used for 80-Year Operation Calculations Crack growth in stainless steel for 80 years uses the updated FCG law for stainless steels and associated weld metals from ASME Code Case N-809 [6]:

da/dN = Co*Af<.n, units of inch/cycle where:

Co n

C

= scaling parameter that accounts for the effect of loading rate and environment on fatigue crack growth rate

= C Sr SR SENV

= slope of the log (da/dN) versus log (Af<.) curve= 2.25

= nominal fatigue crack growth rate constant

= 4.43 X 10-7 for AfZ 2: AfZth

= 0 for t1K < AfZth

= stress intensity factor range, ksi-/in

= 1.10 ksi-/in

= parameter defining effect of temperature on FCG rate

= e-25161TK for 300°F :'ST :'S 650°F

= 3.39x105 e[C-2516/TiJ-0.030ITK.] for 70°F :'ST< 300°F

= metal temperature, °F

= parameter defining the effect ofR-ratio on FCG rate

= 1.0 for R < 0

= 1 + e8.02(R-0.748) for O :'SR< 1.0 File No.: 0901350.304 Revision: 3 Page 15 of 20 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 I:}

Structural Integrity Associates, Inc.

R

= KminlK.max = R ratio SENV

= parameter defining the environmental effects on FCG rate

= TR03 TR

= loading rise time, sec TK

= [(T-32)/1.8+273.15], K L-2018-174Attachment 19 Enclosure 1 Page 17 of73 The metal temperature of 653°F is applied to calculate the crack growth rate. A conservative loading rise time of 15,000 seconds is applied to calculate the crack growth rate.

The crack growth rate changes based on the R-ratio. The da/dN for selected Af( is calculated for different R-ratios and entered into pc-CRACK 4.1 [8a] to calculate crack growth using Code Case N-809 FCG equation. For through-wall crack growth calculation, R-ratio and SR are calculated based on the given Kmin and Kmax and are used to calculate the crack growth rate for Code Case N-809.

3.4.3 Part Through-Wall Crack Growth The crack growth analysis is performed using the fracture mechanics software program pc-CRACK 4.1 [8a]. Based on the guidelines of ASME Code Section XI, IWB-3514, an initial flaw size equal to the allowable depth ofup to 12.5% of wall thickness is postulated. For the crack growth analysis, an aspect ratio a/1 of 0.1 is conservatively assumed for the initial flaw, where 'a' is the flaw depth and 'I' is the flaw length.

The crack growth analysis performed by pc-CRACK 4.1 requires that the allowable material fracture toughness, K1c, be input to stop the analysis when K1c is reached. A typical material K1c value of 135 ksiJ;; for stainless steel is used for the purposes of the fatigue crack growth.

pc-CRACK 4.1 calculates K values for each pipe size for reference uniform tension and pure bending stresses of 1 ksi. The built-in crack model 309: Semi-Elliptical Circumferential Crack in Cylinder on the Inside Surface (Chapuliot) [8a] is used.

The stress intensity factors are determined for a conservative aspect ratio (a/1) of 0.1 and are shown in the output files in Appendix A.1 through A.6. Note that the pressure stresses are taken as uniform stresses whereas the stresses due to the other loads are assumed to vary linearly through the pipe wall.

3.4.4 Through-Wall Crack Growth NUREG-1061, Section 5.2 (g) [9] requires that an evaluation be performed to show that the leakage flaw size is stable during an SSE event. A simplified approach is to determine the crack growth of a through-wall leakage size flaw to demonstrate stability. The initial through-wall flaw is assumed to correspond to the leakage flaw length for the most limiting location. A crack model in pc-CRACK 4.2

[8b] assuming through-wall circumferential crack in a cylinder under tension and bending is used for the stress intensity K calculation.

File No.: 0901350.304 Revision: 3 Page 16 of 20 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 SJ Structural Integrity Associates, Inc.

L-2018-174 Attachment 19 Enclosure 1 Page 18 of73 For the Accumulator Line, the maximum Cim+Cib is 19.02 ksi (Reference [14]), the bounding half leakage flaw size (a) is 2.53 inch (Reference [10], with bending stress= 0 for 5gpm). Note that the maximum stress for SSE event is sum of the operating stress and stress due to SSE loading. The minimum stress for SSE event is ~alculated by subtracting the stress due to SSE from the operating stress, which is -9.14 ksi. The maximum and minimum Cim+Cib are conservatively used as tension stress in the pc-CRACK 4.2 input. The pc-CRACK 4.2 output is shown in Appendix A.7. The resultant stress intensity factors Kmax and Kmin are 69.09 ksiJ;; and -33.20 ksiJ;; for the halfleakage flaw size of2.53 inch.

Similarly, for the RHR Line, the maximum Cim+Cib is 17.38 ksi (Reference [14]), the bounding half leakage flaw size (a) is 3.12 inch (from Reference [10], with bending stress= 0 for 5gpm). The minimum stress for SSE event is calculated by subtracting the stress due to SSE from the operating stress, which is -7.62 ksi. The maximum and minimum Cim+Cib are conservatively used as tension stress in the pc-CRACK 4.2 input. The pc-CRACK 4.2 output is shown in Appendix A.8. The resultant stress intensity factors Kmax and Kmin are 68.86 ksiJ;; and -30.19 ksiJ;; for the halfleakage flaw size of 3.12 inch.

Similarly, for the Surge Line, the maximum Cim+Cib is 24.73 ksi (Reference [14]), the bounding half leakage flaw size (a) is 3.30 inch (Reference [10], with bending stress =0 for 5gpm). The calculated minimum stress is -0.09 ksi. The maximum and minimum Cim+Cib are conservatively used as tension stress in the pc-CRACK 4.2 input. The pc-CRACK 4.2 output is shown in Appendix A.9. The resultant stress intensity factors Kmax and Kmin are 107.35 ksiJ;; and -0.39 ksiJ;; for the halfleakage flaw size of 3.30 inch.

4.0 RESULTS The results of the part through-wall fatigue crack growth evaluations for both 60 years (using the Reference [1] crack growth law) and 80 years of operation (using the Reference [6] crack growth law) are summarized as follows:

Table 4-1: Fatigue Crack Growth Results for Part Through-Wall Flaws Auxiliary Line Accumulator Line RHR.Line Surge Line File No.: 0901350.304 Revision: 3 Postulated Initial Flaw Depth Half a/t Length ai (in)

Ci (in) 12.50%

0.1250 0.6250 12.50%

0.1563 0.7815 12.50%

0.1406 0.7030 60 Years 80 Years (ASME Section XI)

(ASME CC N-809)

Depth Half Depth Half a/t Length a/t Length ar (in) cr (in) ar (in)

Cf (in) 12.50%

0.1250 0.6250 12.50%

0.1250 0.6250 12.50%

0.1563 0.7815 12.62%

0.1577 0.7817 12.57%

0.1414 0.7031 20.10%

0.2261 0.7256 Page 17 of 20 F0306-01Rl

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

L-2018-174 Attachment 19 Enclosure 1 Page 19 of73 Considering the larger growth of 80 years using the crack growth law from ASME Code Case N-809, the results show that the postulated partial through wall crack ( aft = 0.125, a/1 = 0.1) does not grow during the design plant life for the Accumulator Line. For the RHR Line, the postulated crack (a/t =

0.125, a/1 = 0.1) grows only 0.0014 inch during the design plant life to a final a/t ratio of 0.1262. This final alt ratio is less than the allowable ratio of 0.70 documented in Section 3.3. For the Surge Line, the postulated crack (aft= 0.125, a/1 = 0.1) grows 0.0855 inch during the design plant life to a final aft ratio of 0.2010. This final aft ratio is less than the allowable ratio of 0.75 documented in Section 3.3.

As shown in Table 4-1, for a partial through-wall crack in the RHR Line, the crack growth in the depth direction is 0.0014 inch and the crack growth in the length direction is 0.0004 inch. This is about 0.0009% of the 43.96 inch circumference length, and compared to the crack growth of 0.12% (12.50%

to 12.62% in Table 4-1) in the depth direction, it is relatively small. For the Surge Line, the crack growth in the depth direction is 0.0855 inch and the crack growth in the length direction is 0.0452 inch.

This is 0.113% of the 40.03 inch circumference length, and compared to the 7.6% (12.50% to 20.10%

in Table 4-1) in the depth direction, it is relatively small. Overall, for all the lines, the partial through-wall cracks tend to grow in the depth direction and through-wall before extending significantly in length (circumferentially) direction.

For 60 years for the Accumulator Line through wall crack, using a negative R ratio (Kmin1Kmax) in the ASME Code Section XI crack growth curve for stainless steels in a water environment (Figure C-8410-

1) gives a crack growth per cycle of l.81xI0-3 inches, whereas for 80 years the ASME Code Case N-809 crack growth curve gives 4.51 x10-3 inches per cycle. For the assumed 51 cycles of SSE

( conservative representation of 1 SSE and 50 OBE cycles), this growth is 0.092 inches for the ASME Section XI crack growth law and 0.230 inches for the Code Case N-809 crack growth law. Final half flaw sizes (af) are 2.622 inches for the ASME Section XI crack growth law and 2.760 inches for the Code Case N-809 crack growth law. These final half flaw sizes are less than the critical half flaw size (ac) of 4.61 inches with the maximum stress of 19.02 ksi.

Similarly, for 60 years for the RHR Line, using a negative R ratio (Kmin1Kmax) in the ASME Code Section XI crack growth curve for stainless steels in a water environment (Figure C-8410-1 ), the crack growth per cycle is 1.62x 10-3 inches, whereas for 80 years the ASME Code Case N-809 crack growth curve gives 4.19x10-3 inches per cycle. For the assumed 51 cycles of SSE (conservative representation of 1 SSE and 50 OBE cycles), this growth is 0.083 inches for the ASME Section XI crack growth law and 0.214 inches for the Code Case N-809 crack growth law. Final half flaw sizes (af) are 3.203 inches for the ASME Section XI crack growth law aiid 3.334 inches for the Code Case N-809 crack growth law. These final half flaw sizes are less than the critical half flaw size (ac) of 6.35 inches with the maximum stress of 17.38 ksi.

For 60 years for the Surge Line, using a negative R ratio (Kmin/Kmax) in the ASME Code Section XI crack growth curve for stainless steels in a water environment (Figure C-8410-1 ), the crack growth per cycle is 2.14x10-3 inches, whereas for 80 years the ASME Code Case N-809 crack growth curve gives 5.06x10-3 inches per cycle. For the assumed 51 cycles of SSE (conservative representation of 1 SSE and 50 OBE cycles), this growth is 0.109 inches for the ASME Section XI crack growth law and 0.258 File No.: 0901350.304 Revision: 3 Page 18 of20 F0306-0!Rl

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

L-2018-174 Attachment 19 Enclosure 1 Page 20 of73 inches for the Code Case N-809 crack growth law. Final half flaw sizes (af) are 3.409 inches for the ASME Section XI crack growth law and 3.558 inches for the Code Case N-809 crack growth law.

These final half flaw sizes are less than the critical half flaw size (ac) of 4.06 inches with the maximum stress of 24. 73 ksi.

The through-wall crack growth results are summarized in Table 4-2. These results demonstrate that in all cases the final flaw size does not reach the critical flaw size despite the conservative nature of the evaluation.

Table 4-2: Fatigue Crack Growth Results for Through-Wall Flaws Postulated Initial 60 Years Leakage Flaw (ASME Section XI)

Auxiliary Line Half Length Half Length aL (in) ar (in)

Accumulator Line 2.53 2.622 RHRLine 3.12 3.203 Surge Line 3.30 3.409 The pc-CRACK output files are presented in Appendix A.

File No.: 0901350.304 Revision: 3 80 Years (ASMECCN-Critical Flaw Size 809)

Half Length Half Length ar (in) ac (in) 2.760 4.61 3.334 6.35 3.558 4.06 Page 19 of20 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 L-2018-174Attachment 19 Enclosure 1 Page 21 of 73 e

Structural Integrity Associates, Inc.

5.0 REFERENCES

1) ASME Boiler and Pressure Vessel Code,Section XI, 2001 Edition with Addenda through 2003.
2) Material Reliability Program: Characterization ofU. S. Pressurized Water Reactor (PWR) Fleet Operational Transients (MRP-393), EPRI, Palo Alto, CA; 2014, 3002003085.
3) License Renewal Application, Callaway Plant, Unit 1, Facility Operating License No. NPF-30.

http://www.mc.gov/reactors/operating/licensing/renewal/applications/callaway.html

4) "FPL/FLA (Turkey Point 3 and 4) Pressurizer Surge Nozzle Fatigue Calculation Due to Thermal Stratification Pipe Loads", SI File No. 091350.205.
5) SI Calculation Package No. 0901350.301, "Loads and Material Properties for LBB Evaluation" (Please refer to the project revision log for the latest revision).
6) ASME Code Case N-809, "Reference Fatigue Crack Growth Rate Curves for Austenitic Stainless Steels in Pressurized Water Reactor EnvironmentsSection XI, Division 1," Cases of the ASME Boiler and Pressure Vessel Code, June 23, 2015.
7)Section XI Task Group for Piping Flaw Evaluation, ASME Code, "Evaluation of Flaws in Austenitic Steel Piping," Journal of Pressure Vessel Technology, Vol. 108, August 1986.
8) pc-CRACK a) pc-CRACK4.l CS, Version Control No. 4.1.0.0, Structural Integrity Associates, December 31, 2013.

b) pc-CRACK 4.2, Version Control No. 4.2.0.0, Structural Integrity Associates, April 2018.

9) NUREG-1061, Volumes 1-5, "Report of the U.S. Nuclear Regulatory Commission Piping Review Committee," prepared by the Piping Review Committee, NRC, April 1985.
10) SI Calculation Package No. 0901350.302, "Leakage Calculation for LBB Evaluation" (Please refer to the project revision log for the latest revision).
11) "Roark's Formulas for Stress & Strain", Pages 67&94, Sixth Edition, by Warren C. Young, McGraw-Hill Inc., 1989.
12) SI Report No. 1700109.402P, Revision 4, "Evaluation of Fatigue of ASME Section 111, Class 1 Components for Turkey Point Units 3 and 4 for Subsequent License Renewal".
13) Turkey Point Units 3 and 4 License Renewal Document, "Position Document to Address GSI-190 Issues Related to Fatigue Evaluation for Turkey Point Units 3 and 4", SI Report No. SIR 089. Rev 0.
14) SI Calculation Package No. 0901350.303, "Development of Bounding Analysis Curves for LBB Evaluation" (Please refer to the project revision log for the latest revision).
15) SI Corrective Action Report (CAR) No.17-012, Revision 0, "Turkey Point LBB Evaluation, Calculation Package File No.: 0901350.304, Rev. 0, Calculation

Title:

Fatigue Crack Growth Evaluation," April 17, 2017.

File No.: 0901350.304 Revision: 3 Page 20 of20 F0306-01Rl

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

File No.: 0901350.304 Revision: 3 APPENDIX A PC-CRACK OUTPUT L-2018-174Attachment 19 Enclosure 1 Page 22 of 73 Page A-1 of A-52 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251

(> Structural Integrity Associates, Inc.

A.1 ACCUMULATOR LINE 60 YEARS pc-CRACK 4.1 CS Version Control No. 4.1.0.0 Structural Integrity Associates, Inc.

www.structint.com pccrack@structint.com Date: 05/18/2017 15:47 L-2018-17 4 Attachment 19 Enclosure 1 Page 23 of73 Input Data read from C:\\Users\\wwong\\Documents\\Projects\\TurkeyPoint -

1700109\\ACCL_60yr.pcf Analysis

Title:

ACCL_60yr Units Selected: US Customary Linear Dimensions -

inches Stress - ksi Load -

kips Temperature -

deg F Time -

hours Analysis Type: Crack Growth (LEFM)

Crack Growth Calculation Method -

Cycle/Time Stepping Maxinum Number of Load Blocks 1

Block Print Interval= 1 Crack Model: 309-Semi-Elliptical Circumferential Crack in Cylinder on the Inside Surface (Chapuliot)

Crack Depth, a=

0.1250 Half Crack Length, c 0.6250 Wall Thickness, t =

1.0000 Inside Radius, Ri *=

4.3750 Aspect ratio allowed to vary Maximum a/t = 0.8 Crack Depth Print Increment for SIF Tabulation= 0.1 Maximum Aspect Ratio (c/a) for SIF Tabulation= 20 Aspect Ratio Increment for SIF Tabulation= 5 Total Load Cases: 2 Load Case 1:Uniform Stress Type: Stress Coefficients Input by User Coefficient co 1.0000 Coefficient Cl 0.0000 Coefficient C2 0.0000 Coefficient C3 0.0000 Load Case 2:Linear Stress Type: Stress Coefficients Input Coefficient CO Coefficient Cl Coefficient C2 Coefficient C3 Total Load Sub-Blocks: 4 Load Sub-Block# 1 0.0000 1.0000 0.0000 0.0000 Load Sub-block Name: Groupl Maximum by User Load Case Multiplier Load Case ID File No.: 0901350.304 Page A-2 of A-52 Revision: 3 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

2.1930 Uniform Stress 33.0070 Linear Stress Minimum Load Case Multiplier Load Case ID 22.8380 Linear Stress Growth Law: ASMEAusteniticAir Cycles/Time: 40 Temperature: 653 Cale. Interval: 1 Print Interval: 20 Load Sub-Block# 2 Load Sub-block Name: Group2 Maximum Load Case Multiplier Load Case ID 2.6480 Uniform Stress 39.8560 Linear Stress Minimum Load Case Multiplier Load Case ID 1.7370 Uniform Stress 26.1590 Linear Stress Growth Law: ASMEAusteniticAir Cycles/Time: 8 Temperature: 653 Cale. Interval: 1 Print Interval: 4 Load Sub-Block# 3 Load Sub-block Name: Group3 Maximum Load Case Multiplier Load Case ID 4.3860 Uniform Stress 43.1760 Linear Stress Minimum Load Case Multiplier Load Case ID 0.0000 Uniform Stress 22.8380 Linear Stress Growth Law: ASMEAusteniticAir Cycles/Time: 2 Temperature: 653 Cale. Interval: 1 Print Interval: 1 Load Sub-Block# 4 Load Sub-block Name: Group4 Maximum Load Case Multiplier Load Case ID 4.8780 Uniform Stress 33.1660 Linear Stress Minimum Load Case Multiplier Load Case ID 4.8780 Uniform Stress 12.5110 Linear Str~ss Growth Law: ASMEAusteniticAir Cycles/Time: 100 Temperature: 653 Cale. Interval: 1 Print Interval: 50 Material: 1 Sample Material 1: Only a sample Austenitic Stainless Steel in Air environment File No.: 0901350.304 Revision: 3 L-2018-174 Attachment 19 Enclosure 1 Page 24 of73 Page A-3 of A-52 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

(U.S. Customary Units)

The Fatigue Crack Growth Rate (in/cycle) is given by:

da/dN = Co*(Delta K)~n where Delta K = Kmax -

Kmin n = the slope of the log (da/dN) versus log (Delta K) 3.3 Co= a scaling constant Co C*S C is given by:

Tis the metal temperature in deg F Sis a scaling parameter to account for R ratio and is given by:

s

1. 0 for R <= 0 l.O + 1.8
  • R for O < R <= 0.79

-43.35 + 57.97

  • R for 0.79 < R < 1 where R = Kmin / Kmax No. of Data in the KIC Table= 1 Crack Depth 0.0000 messages/Warnings:

KIC 135.0000 Solution for Ri/t of 0.2 and 0.5 will be used Number of Warnings in Inputs: 0 ANALYSIS RESULTS -

STRESS INTENSITY FACTORS Load Case# 1: Uniform Stress


Crack Dimensions ------------

Kat tips a

C c/a =

5.0000 0.1250

0. 6250 0.2250 1.1250 0.3250
1. 6250 0.4250 2.1250 0.5250
2. 6250 0.6250 3.1250
0. 7250
3. 6250 c/a =

10.0000 0.1250

1. 2500 0.2250 2.2500 0.3250 3.2500 0.4250 4.2500 0.5250 5.2500 File No.: 0901350.304 Revision: 3 a/t 0.1250 0.2250 0.3250 0.4250 0.5250 0.6250
0. 7250 0.1250 0.2250 0.3250 0.4250 0.5250 c/a 5.0000 5.0000 5.0000 5.0000 5.0000 5.0000 5.0000 10.0000 10.0000 10.0000 10.0000 10.0000 a

C

0. 657 6 0.3295 0.9124 0.4544 1.157 4 0.5691
1. 4003 0.6801
1. 6661 0.7992
1. 9592 0.9250 2.3325
1. 0718 0.6918 0.2500 0.9768 0.3439 1.2642 0.4273
1. 5608 0.5059
1. 9026 0.5857 L-2018-174 Attachment 19 Enclosure 1 Page 25 of73 Page A-4 of A-52 F0306-0IRI

Turkey Point Units 3 and 4 L-2018-17 4 Attachment 19 Enclosure 1 Docket Nos. 50-250 and 50-251 Page 26 of73 e

Structural Integrity Associates, Inc.

0.6250 6.2500 0.6250 10.0000 2.2888 0.6674

0. 7250 7.2500
0. 7250 10.0000
2. 7'905 0.7590 c/a =

15.0000 0.1250

1. 87 50 0.1250 15.0000 0.7025 0.2130 0.2250 3.3750 0.2250 15.0000 1.0002 0.2920 0.3250 4.8750 0.3250 15.0000 1.3065 0.3609 0.4250 6.3750 0.4250 15.0000
1. 627 9 0.4240 0.5250 7.8750 0.5250 15.0000 2.0067 0.4836 0.6250 9.3750 0.6250 15.0000 2.4302
0. 5413 0.7250 10.8750
0. 7250 15.0000 2.9588 0.5984

'1 c/a =

20.0000 0.1250 2.5000 0.1250 20.0000

0. 707 6 0.1667 0.2250 4.5000 0.2250 20.0000 1.0094 0.2285 0.3250 6.5000 0.3250 20.0000 1.3200 0.2821 0.4250 8.5000 0.4250 20.0000
1. 6464 0.3311 0.5250 10.5000 0.5250 20.0000 2.0311 0.3767 0.6250 12.5000 0.6250 20.0000 2.4621 0.4204
0. 7250 14.5000
0. 7250 20.0000 3.0024 0.4626 Load Case# 2: Linear Stress

Crack Dimensions ------------

Kat tips a

C a/t c/a a

C c/a =

5.0000 0.1250 0.6250 0.1250 5.0000 0.0504 4.509E-03 0.2250 1.1250 0.2250 5.0000 0.1241

0. 0119 0.3250
1. 6250 0.3250 5.0000
0. 222 6 0.0231 0.4250 2.1250 0.4250 5.0000 0.3448 0.0386 0.5250
2. 6250 0.5250 5.0000 0.4956 0.0600 0.6250 3.1250
0. 6250 5.0000 0.6799 0.0878
0. 7250
3. 6250
0. 7250 5.0000 0.9217 0.1256 c/a =

10.0000 0.1250 1.2500 0.1250 10.0000 0.0524 2.236E-03 0.2250 2.2500 0.2250 10.0000 0.1307 6.020E-03 0.3250 3.2500 0.3250 10.0000 0.2377 0.0118 0.4250 4.2500 0.4250 10.0000 0.3739 0.0198 0.5250 5.2500 0.5250 10.0000 0.5474 0.0303 0.6250 6.2500 0.6250 10.0000 0.7644 0.0442

0. 7250 7.2500
0. 7250 10.0000 1.0561 0.0634 c/a =

15.0000 0.1250

1. 87 50 0.1250 15.0000 0.0531
1. 410E-03 0.2250 3.3750 0.2250 15.0000 0.1330 3.790E-03 0.3250 4.8750 0.3250 15.0000 0.2437 7.355E-03 0.4250 6.3750 0.4250 15.0000 0.3861 0.0122 0.5250 7.8750 0.5250 15.0000 0.5704 0.0182 0.6250 9.3750 0.6250 15.0000 0.8016 0.0257
0. 7250 10.8750
0. 7250 15.0000 1.1081 0.0347 c/a =

20.0000 0.1250 2.5000 0.1250 20.0000 0.0534 l.045E-03 0.2250 4.5000 0.2250 20.0000 0.1341 2.809E-03 0.3250 6.5000 0.3250 20.0000 0.2460 5.438E-03 0.4250 8.5000 0.4250 20.0000 0.3902 8.957E-03 0.5250 10.5000 0.5250 20.0000 0.5771 0.0134 0.6250 12.5000 0.6250 20.0000

0. 8118 0.0187 0.7250 14.5000
0. 7250 20.0000 1.1243 0.0249 CRACK GROWTH ANALYSIS RESULTS File No.: 0901350.304 Page A-5 of A-52 Revision: 3 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

Total Cycles

/Time Blocks:

20.0000 40.0000 44.0000 48.0000 49.0000 50.0000 100.0000 150.0000 Maximum number Subblock Cycles

/Time 1

20.0000 40.0000 4.0000 8.0000 1.0000 2.0000 50.0000 100.0000 of blocks Kmax 3.1055 0.8714 3.1055

0. 8714 3.7498 1.0522 3.7498 1.0522 5.0600
1. 63 98 5.0601 1.6398 4.8792
1. 7568 4.8792
1. 7568 reached. The Number of Runtime Warnings: 0
      • End of pc-CRACK output File No.: 0901350.304 Revision: 3 Kmin DeltaK 1.1509 1.9546 0.1030
0. 7 68 4 1.1509 1.9546 0.1030
0. 7 68 4 2.4605 1.2893 0.6903 0.3619 2.4605 1.2893 0.6903 0.3619 1.1509
3. 9092 0.1030
1. 5368 1.1509
3. 9092 0.1030
1. 5368 3.8383 1.0409 1.6636 0.0931 3.8383 1.0409 1.6636 0.0931 analysis terminated.

DaDn

/DaDt 3.205E-09

1. 071E-10 3.205E-09
1. 071E-10
1. 062E-09 l.605E-11
1. 0 62E-09 1.605E-11 2.669E-08 9.678E-10 2.669E-08 9.678E-10 5.806E-10 9.637E-13 5.806E-10 9.637E-13 L-2018-174 Attachment 19 Enclosure 1 Page 27 of73 Crack Dimensions a

alt C

c/a 0.1250 0.1250 0.6250 5.0000 0.1250 0.1250 0.6250 5.0000 0.1250 0.1250 0.6250 5.0000 0.1250 0.1250 0.6250 5.0000 0.1250 0.1250 0.6250 5.0000 0.1250 0.1250 0.6250 5.0000 0.1250 0.1250 0.6250 5.0000 0.1250 0.1250 0.6250 5.0000 Page A-6 of A-52 F0306-0!Rl

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 IJ Structural Integrity Associates, Inc.

A.2 ACCUMULATOR LINE 80 YEARS pc-CRACK 4.1 CS Version Control No. 4.1.0.0 Structural Integrity Associates, Inc.

www.structint.com pccrack@structint.com Date: 05/18/2017 15:03 L-2018-174 Attachment 19 Enclosure 1 Page 28 of73 Input Data read from C:\\Users\\wwong\\Documents\\Projects\\TurkeyPoint -

1700109\\ACCL.pcf Analysis

Title:

ACCL Units Selected: US Customary Linear Dimensions -

inches Stress - ksi Load -

kips Temperature -

deg F Time - hours Analysis Type: Crack Growth (LEFM)

Crack Growth Calculation Method -

Cycle/Time Stepping Maxinum Number of Load Blocks 1

Block Print Interval= 1 Crack Model: 309-Semi-Elliptical Circumferential Crack in Cylinder on the Inside Surface (Chapuliot)

Crack Depth, a=

0.1250 Half Crack Length, d 0.6250 Wall Thickness, t =

1.0000 Inside Radius, Ri =

4.3750 Aspect ratio allowed to vary Maximum a/t = 0.8 Crack Depth Print Increment for SIF Tabulation= 0.1 Maximum Aspect Ratio (c/a) for SIF Tabulation= 20 Aspect Ratio Increment for SIF Tabulation= 5 Total Load Cases: 2 Load Case l:Uniform Stress Type: Stress Coefficients Input by User Coefficient CO Coefficient Cl Coefficient C2 Coefficient C3 1.0000 0.0000 0.0000 0.0000 Load Case 2:Linear Stress Type: Stress Coefficients Input by User Coefficient CO Coefficient Cl Coefficient C2 Coefficient C3 Total Load Sub-Blocks: 4 Load Sub-Block# 1 0.0000 1.0000 0.0000 0.0000 Load Sub-block Name: Groupl Maximum Load Case Multiplier Load Case ID File No.: 0901350.304 Page A-7 of A-52 Revision: 3 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 I)

Structural Integrity Associates, Inc.

2.1930 Uniform Stress 33.0070 Linear Stress Minimum Load Case Multiplier Load Case ID 22.8380 Linear Stress Growth Law: TableDADN Cycles/Time: 20 Cale. Interval: 1 Print Interval: 20 Load Sub-Block# 2 Load Sub-block Name: Group2 Maximum Load Case Multiplier Load Case ID 2.6480 Uniform Stress 39.8560 Linear Stress Minimum Load Case Multiplier Load Case ID 1.7370 Uniform Stress 26.1590 Linear Stress Growth Law:. TableDADN Cycles/Time: 4 Cale. Interval: 1 Print Interval: 4 Load Sub-Block# 3 Load Sub-block Name: Group3 Maximum Load Case Multiplier Load Case ID 4.3860 Uniform Stress 43.1760 Linear Stress Minimum Load Case Multiplier Load Case ID 0.0000 Uniform Stress 22.8380 Linear Stress Growth Law: TableDADN Cycles/Time: 1 Cale. Interval: 1 Print Interval: 1 Load Sub-Block# 4 Load Sub-block Name: Group4 Maximum Load Case Multiplier Load Case ID 4.8780 Uniform Stress 33.1660 Linear Stress Minimum Load Case Multiplier Load Case ID 4.8780 Uniform Stress 12.5110 Linear Stress Growth Law: TableDADN Cycles/Time: 50 Cale. Interval: 1 Print Interval: 50 Material: 1 Sample Material 1: Only a sample Table (da/dn-DK)

No. of R ratios in the tables 5

R Ratio Delta K

-100.0000 da/dn File No.: 0901350.304 Revision: 3 L-2018-174Attachment 19 Enclosure 1 Page 29 of73 Page A-8 of A-52 F0306-01Rl

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

1. OOOE-03 2.410E-14 1.0000 2.410E-14 1.1000 l.680E-07 10.0000 2.410E-05 20.0000 l.150E-04 30.0000 2.850E-04 40.0000 5.450E-04 50.0000 9.000E-04 60.0000
1. 360E-03 70.0000
1. 920E-03 80.0000 2.590E-03 90.0000 3.380E-03 100.0000 4.280E-03 R Ratio 0.1000 Delta K da/dn
1. OOOE-03
2. 420E-14 1.0000 2.420E-14 1.1000
1. 690E-07 10.0000 2.420E-05 20.0000 l.150E-04 30.0000 2.870E-04 40.0000 5.480E-04 50.0000 9.050E-04 60.0000
1. 360E-03 70.0000 l.930E-03 80.0000 2.610E-03 90.0000 3.400E-03 100.0000 4.300E-03 R Ratio 0.5000 Delta K da/dn
1. OOOE-03
2. 740E-14
1. 0000 2.740E-14 1.1000 l.910E-07 10.0000 2.740E-05 20.0000 l.300E-04 30.0000 3.240E-04 40.0000 6.190E-04 50.0000
1. 020E-03 60.0000 l.540E-03 70.0000 2.180E-03 80.0000 2.950E-03 90.0000 3.840E-03 100.0000 4.870E-03 R Ratio 0.7000 Delta K da/dn 1.000E-03 4.050E-14
1. 0000 4.050E-14 1.1000 2.820E-07 10.0000 4.050E-05 20.0000
1. 920E-04 30.0000 4.790E-04 40.0000 9.150E-04 50.0000 l.510E-03 60.0000 2.280E-03 70.0000 3.220E-03 80.0000 4.350E-03 90.0000 5.680E-03 100.0000 7.190E-03 R Ratio 1.0000 Delta K da/dn l.OOOE-03 2.060E-13 File No.: 0901350.304 Revision: 3 L-2018-174 Attachment 19 Enclosure 1 Page 30 of 73 Page A-9 of A-52 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

1. 0000 2.060E-13 1.1000 l.430E-06 10.0000 2.060E-04 20.0000 9.780E-04 30.0000 2.440E-03 40.0000 4.650E-03 50.0000 7.690E-03 60.0000
0. 0116 70.0000 0.0164 80.0000 0.0221 90.0000 0.0289 100.0000 0.0366 No. of Data in the KIC Table 1

Crack Depth 0.0000 messages/Warnings:

KIC 135.0000 Solution for Ri/t of 0.2 and 0.5 will be used Number of Warnings in Inputs: 0 ANALYSIS RESOLTS -

STRESS INTENSITY FACTORS Load Case# 1: Oniform Stress


Crack Dimensions ------------

Kat tips a

C a/t c/a a

C c/a =

5.0000 0.1250 0.6250 0.1250 5.0000 0.6576 0.3295 0.2250 1.1250 0.2250 5.0000 0.9124 0.4544 0.3250

1. 6250 0.3250 5.0000 1.157 4 0.5691 0.4250 2.1250 0.4250 5.0000 1.4003 0.6801 0.5250
2. 6250 0.5250 5.0000
1. 6661 0.7992 0.6250 3.1250 0.6250 5.0000
1. 9592 0.9250
0. 7250
3. 6250
0. 7250 5.0000 2.3325
1. 0718 c/a =

10.0000 0.1250 1.2500 0.1250 10.0000 0.6918 0.2500 0.2250 2.2500 0.2250 10.0000 0.9768 0.3439 0.3250 3.2500 0.3250 10.0000

1. 2642 0.4273 0.4250 4.2500 0.4250 10.0000
1. 5608 0.5059 0.5250 5.2500 0.5250 10.0000 1.9026 0.5857 0.6250 6.2500 0.6250 10.0000 2.2888 0.6674
0. 7250 7.2500
0. 7250 10.0000 2.7905 0.7590 c/a =

15.0000 0.1250

1. 87 50 0.1250 15.0000 0.7025 0.2130 0.2250 3.3750 0.2250 15.0000 1.0002 0.2920 0.3250 4.8750 0.3250 15.0000 1.3065 0.3609 0.4250 6.3750 0.4250 15.0000
1. 627 9 0.4240 0.5250 7.8750 0.5250 15.0000 2.0067 0.4836 0.6250 9.3750 0.6250 15.0000 2.4302 0.5413
0. 7250 10.8750
0. 7250 15.0000 2.9588 0.5984 c/a =

20.0000 0.1250 2.5000 0.1250 20.0000 0.7076 0.1667 0.2250 4.5000 0.2250 20.0000 1.0094 0.2285 0.3250 6.5000 0.3250 20.0000 1.3200 0.2821 0.4250 8.5000 0.4250 20.0000

1. 6464
0. 3311 File No.: 0901350.304 Revision: 3 L-2018-174 Attachment 19 Enclosure 1 Page 31 of 73 Page A-10 of A-52 F0306-01Rl

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

0.5250 10.5000 0.5250 20.0000

2. 0311
0. 37 67 0.6250 12.5000 0.6250 20.0000
2. 4621 0.4204
0. 7250 14.5000
0. 7250 20.0000 3.0024 0.4626 Load Case# 2: Linear Stress

Crack Dimensions ------------

Kat tips a

C a/t c/a a

c/a =

5.0000 0.1250 0.6250 0.1250 5.0000 0.0504 0.2250 1.1250 0.2250 5.0000 0.1241 0.3250

1. 6250 0.3250 5.0000
0. 222 6 0.4250 2.1250 0.4250 5.0000 0.3448 0.5250
2. 6250 0.5250 5.0000 0.4956 0.6250 3.1250 0.6250 5.0000
0. 6799
0. 7250 3.6250
0. 7250 5.0000 0.9217 c/a =

10.0000 0.1250

1. 2500 0.1250 10.0000 0.0524 0.2250 2.2500 0.2250 10.0000 0.1307 0.3250 3.2500
0. 3250 10.0000 0.2377 0.4250 4.2500 0.4250 10.0000 0.3739 0.5250 5.2500 0.5250 10.0000 0.5474
0. 6250 6.2500 0.6250 10.0000 0.7644
0. 7250 7.2500
0. 7250 10.0000 1.0561 c/a =

15.0000 0.1250

1. 87 50 0.1250 15.0000 0.0531 0.2250 3.3750 0.2250 15.0000 0.1330 0.3250 4.8750 0.3250 15.0000 0.2437 0.4250 6.3750 0.4250 15.0000 0.3861 0.5250 7.8750 0.5250 15.0000 0.5704
0. 6250 9.3750 0.6250 15.0000 0.8016
0. 7250 10.8750
0. 7250 15.0000 1.1081 c/a =

20.0000 0.1250 2.5000 0.1250 20.0000 0.0534 0.2250 4.5000 0.2250 20.0000 0.1341 0.3250 6.5000 0.3250 20.0000 0.2460 0.4250 8.5000 0.4250 20.0000 0.3902 0.5250 10.5000 0.5250 20.0000

0. 5771
0. 6250 12.5000 0.6250 20.0000 0.8118
0. 7250 14.5000
0. 7250 20.0000 1.1243 CRACK GROWTH ANALYSIS RESULTS Total Subblock Cycles Cycles

/Time

/Time Krnax Krnin DeltaK Blocks:

1 20.0000 20.0000 3.1058 1.1510

1. 954 7
0. 8715 0.1030 0.7685 24.0000 4.0000 3.7502 2.4608
1. 2895 1.0523 0.6904
0. 3 620 25.0000
1. 0000 5.0606 1.1511 3.9095 1.6400 0.1030
1. 5370 75.0000 50.0000 4.8797 3.8386
1. 0411 1.7570 1.6639 0.0932 Maximum number of blocks reached. The analysis terminated.

Number of Runtime Warnings: 0 File No.: 0901350.304 Revision: 3 C

4.509E-03

0. 0119 0.0231 0.0386 0.0600 0.0878 0.1256 2.236E-03 6.020E-03
0. 0118 0.0198 0.0303 0.0442 0.0634
1. 410E-03 3.790E-03 7.355E-03 0.0122 0.0182 0.0257 0.0347 l.045E-03 2.809E-03 5.438E-03 8.957E-03 0.0134 0.0187 0.0249 DaDn

/DaDt 6.692E-07 2.434E-14 3.702E-07

3. 717E-14 3.045E-06 3.586E-07 5.029E-ll l.546E-13 L-2018-174 Attachment 19 Enclosure 1 Crack a

C 0.1250 0.6250 0.1250 0.6250 0.1250 0.6250 0.1250 0.6250 Dimensions a/t c/a 0.1250 4.9995 0.1250 4.9994 0.1250 4.9993 0.1250 4.9993 Page 32 of73 Page A-11 of A-52 F0306-0IR!

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

      • End of pc-CRACK output***

File No.: 0901350.304 Revision: 3 L-2018-174 Attachment 19 Enclosure 1 Page 33 of73 Page A-12 of A-52 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

A.3 RHR LINE 60 YEARS pc-CRACK 4.1 CS Version Control No. 4.1.0.0 Structural Integrity Associates, Inc.

www.structint.com pccrack@structint.com Date: 05/18/2017 15:46 L-2018-174Attachment 19 Enclosure 1 Page 34 of73 Input Data read from C:\\Users\\wwong\\Documents\\Projects\\TurkeyPoint -

1700109\\RHR_60yr.pcf Analysis

Title:

RHR_60yr Units Selected: US Customary Linear Dimensions -

inches Stress - ksi Load - kips Temperature -

deg F Time - hours Analysis Type: Crack Growth (LEFM)

Crack Growth Calculation Method -

Cycle/Time Stepping Maxinum Number of Load Blocks 1

Block Print Interval= 1 Crack Model: 309-Semi-Elliptical Circumferential Crack in Cylinder on the Inside Surface (Chapuliot)

Crack Depth, a=

0.1563 Half Crack Length, c 0.7815 Wall Thickness, t =

1.2500 Inside Radius, Ri =

5.7500 Aspect ratio allowed to vary Maximum a/t = 0.8 Crack Depth Print Increment for SIF Tabulation= 0.1 Maximum Aspect Ratio (c/a) for SIF Tabulation= 20 Aspect Ratio Increment for SIF Tabulation= 5 Total Load Cases: 2 Load Case 1:Uniform Stress Type: Stress Coefficients Input by User Coefficient CO Coefficient Cl Coefficient C2 Coefficient C3 1.0000 0.0000.

0.0000 0.0000 Load Case 2:Linear Stress Type: Stress Coefficients Input by User Coefficient CO Coefficient Cl Coefficient C2 Coefficient C3 Total Load Sub-Blocks: 7 Load Sub-Block# 1 0.0000

1. 0000 0.0000 0.0000 Load Sub-block Name: Groupl Maximum Load Case Multiplier Load Case ID File No.: 0901350.304 Page A-13 of A-52 Revision: 3 F0306-01RI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

3.9930 Uniform Stress 30.4250 Linear Stress Minimum Load Case Multiplier Load Case ID 0.0000 Uniform Stress 19.6150 Linear Stress Growth Law: ASMEAusteniticAir Cycles/Time: 800 Temperature: 653 Cale. Interval: 1 Print Interval: 200 Load Sub-Block# 2 Load Sub-block Name: Group2 Maximum Load Case Multiplier Load Case ID 3.9930 Uniform Stress 30.6630 Linear Stress Minimum Load Case Multiplier Load Case ID 3.9930 Uniform Stress 30.1880 Linear Stress Growth Law: ASMEAusteniticAir Cycles/Time: 2000 Temperature: 653 Cale. Interval: 1 Print Interval: 500 Load Sub-Block# 3 Load Sub-block Name: Group3 Maximum Load Case Multiplier Load Case ID 4.1340 Uniform Stress 31.7860 Linear Stress Minimum Load Case Multiplier Load Case ID 3.8520 Uniform Stress 29.0650 Linear Stress Growth Law: ASMEAusteniticAir Cycles/Time: 16400 Temperature: 653 Cale. Interval: 1 Print Interval: 13200 Load Sub-Block# 4 Load Sub-block Name: Group4 Maximum Load Case Multiplier Load Case ID 4.2200 Uniform Stress 30.6410 Linear Stress Minimum Load Case Multiplier Load Case ID 3.7670 Uniform Stress 30.2100 Linear Stress Growth Law: ASMEAusteniticAir Cycles/Time: 8000 Temperature: 653 Cale. Interval: 1 Print Interval: 2000 Load Sub-Block# 5 Load Sub-block Name: Groups Maximum Load Case Multiplier Load Case ID 5.1120 Uniform Stress L-2018-174 Attachment 19 Enclosure 1 Page 35 of73 File No.: 0901350.304 Page A-14 of A-52 Revision: 3 F0306-01Rl

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

33.8640 Linear Stress Minimum Load Case Multiplier Load Case ID 2.8750 Uniform Stress 26.9870 Linear Stress Growth Law: ASMEAusteniticAir Cycles/Time: 20 Temperature: 653 Cale. Interval: 1 Print Interval: 10 Load Sub-Block# 6 Load Sub-block Name: Group6 Maximum Load Case Multiplier Load Case ID 5.6530 Uniform Stress 30.4250 Linear Stress Minimum Load Case Multiplier Load Case ID 2.3340 Uniform Stress 30.4250 Linear Stress Growth Law: ASMEAusteniticAir Cycles/Time: 400 Temperature: 653 Cale. Interval: 1 Print Interval: 200 Load Sub-Block# 7 Load Sub-block Name: Group7 Maximum Load Case Multiplier Load Case ID 4.6365 Uniform Stress 25.1430 Linear Stress Minimum Load Case Multiplier Load Case ID 4.6365 Uniform Stress 14.0870 Linear Stress Growth Law: ASMEAusteniticAir Cycles/Time: 100 Temperature: 653 Cale. Interval: 1 Print Interval: 50 Material: 1 Sample Material 1: Only a sample Austenitic Stainless Steel in Air environment (U.S. Customary Units)

The Fatigue Crack Growth Rate (in/cycle) is given by:

da/dN = Co*(Delta K)An where Delta K = Kmax -

Kmin n = the slope of the log (da/dN) versus log (Delta K) 3.3 Co= a scaling constant Co C*S C is given by:

File No.: 0901350.304 Revision: 3 L-2018-174 Attachment 19 Enclosure 1 Page 36 of73 Page A-15 of A-52 F0306-01Rl

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

Tis the metal temperature in deg F Sis a scaling parameter to account for R ratio and is given by:

s

1. 0 for R <= 0 1.0 + 1.8
  • R for O < R <= 0.79

-43.35 + 57.97

  • R for 0.79 < R < 1 where R = Krnin / Krnax No. of Data in the KIC Table= 1 Crack Depth 0.0000 messages/Warnings:

KIC 135.0000 Solution for Ri/t of 0.2 and 0.5 will be used Number of Warnings in Inputs: 0 ANALYSIS RESULTS -

STRESS INTENSITY FACTORS Load Case ll 1: Uniform Stress


Crack Dimensions ------------

Kat tips a

C a/t c/a a

C c/a =

5.0000 0.1563 0.7815 0.1250 5.0000 0.7359 0.3686 0.2563 1.2815 0.2050 5.0000

0. 9643 0.4814 0.3563
1. 7815 0.2850 5.0000 1.1889
0. 5872 0.4563 2.2815 0.3650 5.0000 1.4041 0.6867 0.5563 2.7815 0.4450 5.0000
1. 6298 0.7894 0.6563 3.2815 0.5250 5.0000
1. 8689 0.8969
0. 7563 3.7815 0.6050 5.0000 2.1168 1.0063 0.8563 4.2815 0.6850 5.0000 2.4427 1.1365
0. 9563 4.7815 0.7650 5.0000 2.7824 1.2705 c/a =

10.0000 0.1563

1. 5630 0.1250 10.0000 0.7744 0.2796 0.2563 2.5630 0.2050 10.0000 1.0284 0.3648 0.3563 3.5630 0.2850 10.0000 1.2885 0.4421 0.4563 4.5630
0. 3 650 10.0000 1.5440 0.5138 0.5563 5.5630 0.4450 10.0000 1.8244 0.5848 0.6563 6.5630 0.5250 10.0000 2.1323
0. 6565 0.7563 7.5630 0.6050 10.0000 2.4575
0. 7281
0. 8563 8.5630 0.6850 10.0000 2.9002 0.8090 0.9563 9.5630 0.7650 10.0000 3.3663 0.8910 c/a =

15.0000 0.1563 2.3445 0.1250 15.0000 0.7865 0.2382 0.2563 3.8445 0.2050 15.0000

1. 0511 0.3102
0. 3563 5.3445 0.2850 15.0000
1. 3258 0.3740 0.4563 6.8445 0.3650 15.0000
1. 5984 0.4325 0.5563 8.3445 0.4450 15.0000 1.9037 0.4878
0. 6563 9.8445 0.5250 15.0000 2.2442 0.5409 0.7563 11.3445 0.6050 15.0000 2.6050 0.5926 0.8563 12.8445 0.6850 15.0000 3.0799 0.6442 File No.: 0901350.304 Revision: 3 L-2018-17 4 Attachment 19 Enclosure 1 Page 37 of73 Page A-16 of A-52 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

0.9563 14.3445 0.7650 15.0000 c/a =

20.0000 0.1563 3.1260 0.1250 20.0000 0.2563 5.1260 0.2050 20.0000 0.3563 7.12 60 0.2850 20.0000 0.4563 9.1260 0.3650 20.0000 0.5563 11.1260 0.4450 20.0000 0.6563 13.1260 0.5250 20.0000 0.7563 15.1260 0.6050 20.0000 0.8563 17.1260 0.6850 20.0000 0.9563 19.12 60 0.7650 20.0000 Load Case# 2: Linear Stress


Crack Dimensions ------------

a C

a/t c/a c/a =

5.0000 0.1563 0.7815 0.1250 5.0000 0.2563 1.2815 0.2050 5.0000 0.3563

1. 7815 0.2850 5.0000 0.4563 2.2815 0.3650 5.0000 0.5563 2.7815 0.4450 5.0000 0.6563 3.2815 0.5250 5.0000
0. 7 5 63 3.7815 0.6050 5.0000 0.8563 4.2815 0.6850 5.0000 0.9563 4.7815 0.7650 5.0000 c/a =

10.0000 0.1563

1. 5630 0.1250 10.0000
0. 2563 2.5630 0.2050 10.0000 0.3563 3.5630 0.2850 10.0000 0.4563 4.5630
0. 3650 10.0000 0.5563 5.5630 0.4450 10.0000
0. 6563 6.5630 0.5250 10.0000 0.7563 7.5630 0.6050 10.0000 0.8563 8.5630 0.6850 10.0000 0.9563 9.5630 0.7650 10.0000 c/a =

15.0000 0.1563 2.3445 0.1250 15.0000 0.2563 3.8445 0.2050 15.0000

0. 35 63 5.3445 0.2850 15.0000 0.4563 6.8445 0.3650 15.0000 0.5563 8.3445 0.4450 15.0000
0. 6563 9.8445 0.5250 15.0000 0.7563 11.3445 0.6050 15.0000 0.8563 12.8445 0.6850 15.0000 0.9563
14. 3445 0.7650 15.0000 c/a =

20.0000 0.1563 3.1260 0.1250 20.0000 0.2563 5.1260 0.2050 20.0000 0.3563 7.12 60 0.2850 20.0000 0.4563 9.1260 0.3650 20.0000 0.5563 11.12 60 0.4450 20.0000

0. 6563 13.1260 0.5250 20.0000 0.7563 15.1260 0.6050 20.0000 0.8563 17.1260 0.6850 20.0000 0.9563 19.1260 0.7650 20.0000 CRACK GROWTH ANALYSIS RESULTS File No.: 0901350.304 Revision: 3 3.5803 0.6952 0.7923 0.1864 1.0606 0.2427 1.3396 0.2924 1.6168 0.3379
1. 927 5 0.3806 2.2741 0.4212 2.6415 0.4605 3.1259 0.4989 3.6365 0.5366 Kat tips a

C 0.0705 6.312E-03 0.1500 0.0141 0.2525 0.0255 0.3756 0.0404 0.5221 0.0598 0.6940 0.0844 0.8912 0.1144 1.1469 0.1541 1.4400 0.2011 0.0733 3.132E-03 0.1575 7.152E-03 0.2682 0.0130 0.4032 0.0207 0.5681 0.0305 0.7662 0.0427 0.9975 0.0575 1.3067 0.0776

1. 6660 0.1013 0.0743 l.976E-03 0.1601 4.516E-03 0.2741 8.106E-03 0.4140 0.0128 0.5871 0.0186 0.7974 0.0255
1. 044 7 0.0337
1. 3723 0.0433
1. 7538 0.0542 0.0747 l.465E-03 0.1614 3.349E-03 0.2766 5.996E-03 0.4184 9.425E-03 0.5939 0.0136 0.8073 0.0187
1. 0585 0.0246 1.3921 0.0312
1. 7808 0.0387 L-2018-174 Attachment 19 Enclosure 1 Page 38 of73 Page A-17 of A-52 F0306-01Rl

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

Total Subblock Cycles Cycles

/Time

/Time Kmax Blocks:

1 200.0000 200.0000 5.0834 1.6639 400.0000 400.0000 5.0835 1.6640 600.0000 600.0000 5.0836 1.6640 800.0000 800.0000 5.0838 1.6641 1300. 0000 500.0000 5.1005

1. 6656 1800.0000 1000.0000 5.1005
1. 6656 2300.0000 1500.0000 5.1005
1. 6656 2800.0000 2000.0000 5.1005 1.6656
1. 600E+04 l.320E+04 5.2835 1.7247
1. 920E+04
1. 640E+04 5.2835 1.7247 2.120E+04 2000.0000 5.2661
1. 7492 2.320E+04 4000.0000 5.2661
1. 7 492 2.520E+04 6000.0000 5.2661
1. 7492
2. 720E+04 8000.0000 5.2661
1. 7492
2. 721E+04 10.0000 6.1498 2.0984
2. 722E+04 20.0000 6.1498 2.0984 2.742E+04 200.0000 6.3056 2.2761 2.762E+04 400.0000 6.3056 2.2762 2.767E+04 50.0000 5.1851
1. 8 681
2. 772E+04 100.0000 5.1851
1. 8 681 Maximum number of blocks reached. The Number of Runtime Warnings: 0
      • End of pc-CRACK output***

File No.: 0901350.304 Revision: 3 Kmin DeltaK 1.3827 3.7006 0.1238

1. 5401 1.3828 3.7007 0.1238
1. 5402 1.3829 3.7008 0.1238
1. 5402 1.3829 3.7008 0.1238
1. 5403 5.0671 0.0335 1.6626 2.999E-03 5.0671 0.0335
1. 6626 2.999E-03
5. 0 671 0.0335
1. 6626 2.999E-03
5. 0 671 0.0335 1.6626 2.999E-03 4.8841 0.3994 1.6036.

0.1211 4.8842 0.3994

1. 6036 0.1211 4.9023 0.3638 1.5795 0.1697 4.9023 0.3638
1. 57 95 0.1697 4.9023 0.3638 1.5795 0.1697 4.9023 0.3638
1. 57 95 0.1697 4.0186 2.1312 1.2303 0.8681 4.0186 2.1312 1.2303 0.8681 3.8629 2.4427 1.0526
1. 223 6 3.8629 2.4427 1.0526
1. 223 6 4.4056 0.7795
1. 7982 0.0698 4.4056 0.7795
1. 7 982 0.0698 analysis terminated.

L-2018-174 Attachment 19 Enclosure 1 Page 39 of73 DaDn

/DaDt Crack Dimensions a

a/t C

c/a 2.354E-08 0.1563 0.1250 9.930E-10 0.7815 4.9999 2.354E-08 0.1563 0.1250 9.931E-10 0.7815 4.9997 2.354E-08 0.1563 0.1251 9.932E-10 0.7815 4.9996 2.354E-08 0.1563 0.1251 9.933E-10 0.7815 4.9994 4.065E-14 0.1563 0.1251 l.443E-17 0.7815 4.9994 4.065E-14 0.1563 0.1251 1.443E-17 0.7815 4.9994 4.065E-14 0.1563 0.1251 l.443E-17 0.7815 4.9994 4.065E-14 0.1563 0.1251

1. 443E-17 0.7815 4.9994 l.043E-10 0.1563 0.1251 2.096E-12 0.7815 4.9994 l.043E-10 0.1563 0.1251 2.096E-12 0.7815 4.9993
7. 945E-ll 0.1563 0.1251 5.439E-12 0.7815 4.9993
7. 945E-11 0.1563 0.1251 5.439E-12 0.7815 4.9993 7.945E-11 0.1563 0.1251 5.439E-12 0.7815 4.9993 7.945E-ll 0.1563 0.1251 5.439E-12 0.7815 4.9993 5.566E-09 0.1563 0.1251 2.714E-10 0.7815 4.9993 5.566E-09 0.1563 0.1251
2. 714E-10 0.7815 4.9993 8.436E-09 0.1563 0.1251 7.509E-10 0.7815 4.9993
8. 436E-09 0.1563 0.1251 7.510E-10 0.7815 4.9992 5.466E-10 0.1563 0.1251
4. 014E-13 0.7815 4.9992 5.466E-10 0.1563 0.1251 4.014E-13 0.7815 4.9992 Page A-18 of A-52 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

A.4 RHR LINE 80 YEARS pc-CRACK 4.1 CS Version Control No. 4.1.0.0 Structural Integrity Associates, Inc.

www.structint.com pccrack@structint.com Date: 05/18/2017 14:15 L-2018-174 Attachment 19 Enclosure 1 Page 40 of 73 Input Data read from C:\\Users\\wwong\\Documents\\Projects\\TurkeyPoint -

1700109\\RHR.pcf Analysis

Title:

RHR Units Selected: US Customary Linear Dimensions -

inches Stress - ksi Load -

kips Temperature -

deg F Time -

hours Analysis Type: Crack Growth (LEFM)

Crack Growth Calculation Method -

Cycle/Time Stepping Maxinum Number of Load Blocks 1

Block Print Interval= 1 Crack Model: 309-Semi-Elliptical Circumferential Crack in Cylinder on the Inside Surface (Chapuliot)

Crack Depth, a=

0.1563 Half Crack Length, c 0.7815 Wall Thickness, t =

1.2500 Inside Radius, Ri =

5.7500 Aspect ratio allowed to vary Maximum a/t = 0.8 Crack Depth Print Increment for SIF Tabulation= 0.1 Maximum Aspect Ratio (c/a) for SIF Tabulation= 20 Aspect Ratio Increment for SIF Tabulation= 5 Total Load Cases: 2 Load Case l:Uniform Stress Type: Stress Coefficients Input by User Coefficient CO Coefficient Cl Coefficient C2 Coefficient C3 1.0000 0.0000 0.0000 0.0000 Load Case 2:Linear Stress Type: Stress Coefficients Input by User Coefficient CO Coefficient Cl Coefficient C2 Coefficient C3 Total Load Sub-Blocks: 7 Load Sub-Block# 1 0.0000 1.0000 0.0000 0.0000 Load Sub-block Name: Groupl Maximum Load Case Multiplier Load Case ID File No.: 0901350.304 Page A-19 of A-52 Revision: 3 F0306-01Rl

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

3.9930 Uniform Stress 30.4250 Linear Stress Minimum Load Case Multiplier Load Case ID 0.0000 Uniform Stress 19.6150 Linear Stress Growth Law: TableDADN Cycles/Time: 400 Cale. Interval: 1 Print Interval: 200 Load Sub-Block# 2 Load Sub-block Name: Group2 Maximum Load Case Multiplier Load Case ID 3.9930 Uniform Stress 30.6630 Linear Stress Minimum Load Case Multiplier Load Case ID 3.9930 Uniform Stress 30.1880 Linear Stress Growth Law: TableDADN Cycles/Time: 1000 Cale. Interval: 1 Print Interval: 500 Load Sub-Block# 3 Load Sub-block Name: Group3 Maximum Load Case Multiplier Load Case ID 4.1340 Uniform Stress 31.7860 Linear Stress Minimum Load Case Multiplier Load Case ID 3.8520 Uniform Stress 29.0650 Linear Stress Growth Law: TableDADN Cycles/Time: 13200 Cale. Interval: 1 Print Interval: 13200 Load Sub-Block# 4 Load Sub-block Name: Group4 Maximum Load Case Multiplier Load Case ID 4.2200 Uniform Stress 30.6410 Linear Stress Minimum Load Case Multiplier Load Case ID 3.7670 Uniform Stress 30.2100 Linear Stress Growth Law: TableDADN Cycles/Time: 4000 Cale. Interval: 1 Print Interval: 2000 Load Sub-Block# 5 Load Sub-block Name: Groups Maximum Load Case Multiplier Load Case ID 5.1120 Uniform Stress 33.8640 Linear Stress Minimum Load Case Multiplier Load Case ID 2.8750 Uniform Stress L-2018-17 4 Attachment 19 Enclosure 1 Page 41 of 73 File No.: 0901350.304 Page A-20 of A-52 Revision: 3 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

26.9870 Linear Stress Growth Law: TableDADN Cycles/Time: 10 Cale. Interval: 1 Print Interval: 10 Load Sub-Block# 6 Load Sub-block Name: Group6 Maximum Load Case Multiplier Load Case ID 5.6530 Uniform Stress 30.4250 Linear Stress Minimum Load Case Multiplier Load Case ID 2.3340 Uniform Stress 30.4250 Linear Stress Growth Law: TableDADN Cycles/Time: 200 Cale. Interval: 1 Print Interval: 200 Load Sub-Block# 7 Load Sub-block Name: Group7 Maximum Load Case Multiplier Load Case ID 4.6365 Uniform Stress 25.1430 Linear Stress Minimum Load Case Multiplier Load Case ID 4.6365 Uniform Stress 14.0870 Linear Stress Growth Law: TableDADN Cycles/Time: 50 Cale. Interval: 1 Print Interval: 50 Material: 1 Sample Material 1: Only a sample Table(da/dn-DK)

No. of R ratios in the tables R Ratio

-100.0000 Delta K da/dn

1. OOOE-03 2.410E-14 1.0000 2.410E-14 1.1000 l.680E-07 10.0000 2.410E-05 20.0000 l.150E-04 30.0000 2.850E-04 40.0000 5.450E-04 50.0000 9.000E-04 60.0000
1. 360E-03 70.0000
1. 920E-03 80.0000 2.590E-03 90.0000 3.380E-03 100.0000 4.280E-03 R Ratio 0.1000 Delta K da/dn l.OOOE-03 2.420E-14
1. 0000 2.420E-14 1.1000
1. 690E-07 File No.: 0901350.304 Revision: 3 5

L-2018-174 Attachment 19 Enclosure 1 Page 42 of73 Page A-21 of A-52 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

10.0000 2.420E-05 20.0000 l.150E-04 30.0000 2.870E-04 40.0000 5.480E-04 50.0000 9.050E-04 60.0000 1.360E-03 70.0000

1. 930E-03 80.0000 2.610E-03 90.0000 3.400E-03 100.0000 4.300E-03 R Ratio 0.5000 Delta K da/dn
1. OOOE-03 2.740E-14 1.0000 2.740E-14 1.1000 l.910E-07 10.0000 2.740E-05 20.0000
1. 300E-04 30.0000 3.240E-04 40.0000 6.190E-04 50.0000
1. 020E-03 60.0000
1. 540E-03 70.0000 2.180E-03 80.0000 2.950E-03 90.0000 3.840E-03 100.0000 4.870E-03 R Ratio 0.7000 Delta K da/dn l.OOOE-03 4.050E-14
1. 0000 4.050E-14 1.1000 2.820E-07 10.0000 4.050E-05 20.0000
1. 920E-04 30.0000 4.790E-04 40.0000 9.150E-04 50.0000 l.510E-03 60.0000 2.280E-03 70.0000 3.220E-03 80.0000 4.350E-03 90.0000 5.680E-03 100.0000 7.190E-03 R Ratio 1.0000 Delta K da/dn
1. OOOE-03 2.060E-13 1.0000 2.060E-13 1.1000
1. 430E-06 10.0000 2.060E-04 20.0000 9.780E-04 30.0000 2.440E-03 40.0000 4.650E-03 50.0000 7.690E-03 60.0000
0. 0116 70.0000 0.0164 80.0000 0.0221 90.0000 0.0289 100. 0000.

0.0366 No. of Data in the KIC Table 1

Crack Depth 0.0000 messages/Warnings:

KIC 135.0000 Solution for Ri/t of 0.2 and 0.5 will be used File No.: 0901350.304 Revision: 3 L-2018-174 Attachment 19 Enclosure 1 Page 43 of73 Page A-22 of A-52 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

Number of Warnings in Inputs: 0 ANALYSIS RESULTS -

STRESS INTENSITY FACTORS Load Case# 1: Uniform Stress


Crack Dimensions------------

a c

a/t c/a c/a =

0.1563 0.2563 0.3563 0.4563 0.5563 0.6563 0.7563 0.8563 0.9563 c/a =

0.1563 0.2563 0.3563 0.4563 0.5563 0.6563 0.7563 0.8563 0.9563 c/a =

0.1563 0.2563 0.3563 0.4563 0.5563 0.6563 0.7563 0.8563 0.9563 c/a =

0.1563 0.2563 0.3563 0.4563 0.5563 0.6563 0.7563 0.8563 0.9563 5.0000 0.7815

1. 2815
1. 7815 2.2815 2.7815 3.2815 3.7815 4.2815 4.7815 10.0000
1. 5630 2.5630 3.5630 4.5630 5.5630 6.5630 7.5630 8.5630 9.5630 15.0000 2.3445 3.8445 5.3445 6.8445 8.3445 9.8445 11.3445 12.8445 14.3445 20.0000 3.12 60 5.12 60 7.12 60 9.12 60 11.12 60 13.1260 15.1260 17.1260 19.1260 0.1250 0.2050 0.2850 0.3650 0.4450 0.5250 0.6050 0.6850 0.7650 0.1250 0.2050 0.2850 0.3650 0.4450 0.5250 0.6050 0.6850 0.7650 0.1250 0.2050 0.2850 0.3650 0.4450 0.5250 0.6050 0.6850 0.7650 0.1250 0.2050 0.2850 0.3650 0.4450 0.5250 0.6050 0.6850 0.7650 Load Case# 2: Linear Stress 5.0000 5.0000 5.0000 5.0000 5.0000 5.0000 5.0000 5.0000 5.0000 10.0000 10.0000 10.0000 10.0000 10.0000 10.0000 10.0000 10.0000 10.0000 15.0000 15.0000 15.0000 15.0000 15.0000 15.0000 15.0000 15.0000 15.0000 20.0000 20.0000 20.0000 20.0000 20.0000 20.0000 20.0000 20.0000 20.0000

Crack Dimensions------------

a c

a/t c/a c/a =

5.0000 0.1563 0.2563 0.7815

1. 2815 File No.: 0901350.304 Revision: 3 0.1250 0.2050 5.0000 5.0000 Kat tips a

C 0.7359 0.9643 1.188 9

1. 4041
1. 62 9 8
1. 8 68 9 2.1168 2.4427 2.7824 0.7744
1. 02 8 4 1.2885 1.5440 1.8244 2.1323 2.4575 2.9002 3.3663 0.7865
1. 0511 1.3258 1.5984
1. 9037 2.2442
2. 6050 3.0799 3.5803 0.7923
1. 060 6 1.3396
1. 6168
1. 927 5 2.2741 2.6415 3.1259 3.6365 0.3686 0.4814 0.5872 0.6867 0.7894 0.8969 1.0063 1.1365 1.2705 0.2796 0.3648 0.4421 0.5138 0.5848 0.6565
0. 7281 0.8090 0.8910 0.2382 0.3102 0.3740 0.4325 0.4878 0.5409 0.5926 0.6442 0.6952 0.1864 0.2427 0.2924 0.3379 0.3806 0.4212 0.4605 0.4989 0.5366 Kat tips a

C 0.0705 0.1500 6.312E-03 0.0141 L-2018-174 Attachment 19 Enclosure 1 Page 44 of73 Page A-23 of A-52 F0306-01RI

Turkey Point Units 3 and 4 L-2018-174 Attachment 19 Enclosure 1 Docket Nos. 50-250 and 50-251 Page 45 of73 e

Structural Integrity Associates, Inc.

0. 3563
1. 7815 0.2850 5.0000 0.2525 0.0255
0. 4563 2.2815 0.3650 5.0000 0.3756 0.0404
0. 5563 2.7815 0.4450 5.0000 0.5221 0.0598
0. 6563 3.2815 0.5250 5.0000 0.6940 0.0844
0. 7563 3.7815 0.6050 5.0000 0.8912 0.1144 0.8563 4.2815 0.6850 5.0000 1.1469 0.1541
0. 9563 4.7815 0.7650 5.0000 1.4400
0. 2011 c/a =

10.0000 0.1563 1.5630 0.1250 10.0000 0.0733 3.132E-03 0.2563 2.5630 0.2050 10.0000 0.1575 7.152E-03

0. 3563 3.5630 0.2850 10.0000 0.2682 0.0130 0.4563 4.5630 0.3650 10.0000 0.4032 0.0207 0.5563 5.5630 0.4450 10.0000 0.5681 0.0305 0.6563 6.5630 0.5250 10.0000 0.7662 0.0427 0.7563 7.5630 0.6050 10.0000 0.9975 0.0575 0.8563 8.5630 0.6850 10.0000
1. 3067 0.0776 0.9563 9.5630 0.7650 10.0000
1. 6660 0.1013 c/a =

15.0000 0.1563 2.3445 0.1250 15.0000 0.0743

1. 976E-03 0.2563 3.8445 0.2050 15.0000 0.1601 4.516E-03 0.3563 5.3445 0.2850 15.0000 0.2741 8.106E-03 0.4563 6.8445 0.3650 15.0000 0.4140 0.0128 0.5563 8.3445 0.4450 15.0000 0.5871 0.0186
0. 6563 9.8445 0.5250 15.0000
0. 7974 0.0255
0. 7563
11. 3445 0.6050 15.0000 1.0447 0.0337 0.8563 12.8445 0.6850 15.0000
1. 3723 0.0433
0. 9563 14.3445 0.7650 15.0000
1. 7 538 0.0542 c/a =

20.0000 0.1563 3.1260 0.1250 20.0000 0.0747 l.465E-03 0.2563 5.1260 0.2050 20.0000 0.1614 3.349E-03 0.3563 7.1260 0.2850 20.0000 0.2766 5.996E-03 0.4563 9.1260 0.3650 20.0000 0.4184 9.425E-03 0.5563 11.1260 0.4450 20.0000 0.5939 0.0136 0.6563 13.1260 0.5250 20.0000 0.8073 0.0187 0.7563 15.1260 0.6050 20.0000 1.0585 0.0246 0.8563 17.1260 0.6850 20.0000

1. 3921 0.0312 0.9563 19.1260 0.7650 20.0000
1. 7808 0.0387 CRACK GROWTH ANALYSIS RESULTS Total Subblock Cycles Cycles DaDn

/Time

/Time Kmax Kmin DeltaK

/DaDt Crack Dimensions a

a/t C

c/a Blocks:

1 200.0000 200.0000 5.0984 1.3896 3.7088 2.742E-06 0.1568 0.1255

1. 6704 0.1249
1. 5455 3.631E-07 0.7816 4.9830 400.0000 400.0000 5.1137 1.3966 3.7171 2.757E-06 0.1574 0.1259
1. 6770 0.1260
1. 5510 3.660E-07 0.7816 4.9661 900.0000 500.0000 5.1307 5.0969 0.0338 l.988E-13 0.1574 0.1259
1. 6785
1. 67 55 3.052E-03 2.040E-13 0.7816 4.9661 1400. 0000 1000.0000 5.1307 5.0969 0.0338 l.988E-13 0.1574 0.1259
1. 6785
1. 67 55 3.052E-03 2.040E-13 0.7816 4.9661
1. 460E+04
1. 32 OE+04 5.3148 4.9129 0.4019 l.367E-13 0.1574 0.1259
1. 7381
1. 6160 0.1221 1.408E-13 0.7816 4.9661 l.660E+04 2000.0000 5.2967 4.9316 0.3651 l.418E-13 0.1574 0.1259
1. 7626 1.5918 0.1708 1.218E-13 0.7816 4.9661
1. 8 60E+04 4000.0000 5.2967 4.9316 0.3651
1. 418E-13 0.1574 0.1259
1. 7626
1. 5918 0.1708 l.218E-13 0.7816 4.9661 l.861E+04 10.0000 6.1850 4.0440 2.1410 l.153E-06 0.1574 0.1259 File No.: 0901350.304 Page A-24 of A-52 Revision: 3 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

2.1145

1. 881E+04 200.0000 6.3484 2.2976
1. 886E+04 50.0000 5.2204 1.8857
1. 2402 0.8742 3.8965 2.4519 1.0640 1.2336 4.4310 0.7894 1.8143
0. 0714 Maximum number of blocks reached. The analysis terminated.

Number of Runtime Warnings: 0

      • End of pc-CRACK output***

File No.: 0901350.304 Revision: 3 3.245E-14

1. 447E-06 2.444E-07 9.075E-14 l.678E-13 L-2018-174 Attachment 19 Enclosure 1 Page 46 of 73 0.7816 4.9657 0.1577 0.1262 0.7817 4.9569 0.1577 0.1262 0.7817 4.9569 Page A-25 of A-52 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 I)

Structural Integrity Associates, Inc.

A.5 SURGE LINE 60 YEARS pc-CRACK 4.1 CS Version Control No. 4.1.0.0 Structural Integrity Associates, Inc.

www.structint.com pccrack@structint.com Date: 05/18/2017 15:43 L-2018-174 Attachment 19 Enclosure 1 Page 47 of73 Input Data read from C:\\Users\\wwong\\Documents\\Projects\\TurkeyPoint - 1700109\\surge_60yr.pcf Analysis

Title:

Surge_60yr Units Selected: US Customary Linear Dimensions -

inches Stress - ksi Load -

kips.

Temperature -

deg F Time - hours Analysis Type: Crack Growth (LEFM)

Crack Growth Calculation Method -

Cycle/Time stepping Maxinum Number of Load Blocks 1

Block Print Interval= 1 Crack Model: 309-Semi-Elliptical Circumferential Crack in Cylinder on the Inside Surface (Chapuliot)

Crack Depth, a=

0.1406 Half Crack Length, c 0.7030 Wall Thickness, t =

1.1250 Inside Radius, Ri =

5.2500 Aspect ratio allowed to vary Maximum a/t = 0.8 Crack Depth Print Increment for SIF Tabulation= 0.1 Maximum Aspect Ratio (c/a) for SIF Tabulation= 20 Aspect Ratio Increment for SIF Tabulation= 5 Total Load Cases: 2 Load Case 1:Uniform Stress Type: Stress Coefficients Input by User Coefficient CO Coefficient Cl Coefficient C2 Coefficient C3 1.0000 0.0000 0.0000 0.0000 Load Case 2:Linear Stress Type: Stress Coefficients Input by User Coefficient CO Coefficient Cl Coefficient C2 Coefficient C3 0.0000 1.0000 0.0000 0.0000 Total Load Sub-Blocks: 16 Load Sub-Block# 1 Load Sub-block Name: Groupl Maximum Load Case Multiplier Load Case ID File No.: 0901350.304 Page A-26 of A-52 Revision: 3 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

4.7420 Uniform Stress 23.6960 Linear Stress Minimum Load Case Multiplier Load Case ID 10.1010 Linear Stress Growth Law: ASMEAusteniticAir Cycles/Time: 400 Temperature: 653 Cale. Interval: 1 Print Interval: 200 Load Sub-Block# 2 Load Sub-block N~e: Group2 Maximum Load Case Multiplier Load Case ID 4.7420 Uniform Stress 28.1210 Linear Stress Minimum Load Case Multiplier Load Case ID 29.4300 Linear Stress Growth Law: ASMEAusteniticAir Cycles/Time: 16400 Temperature: 653 Cale. Interval: 1 Print Interval: 13200 Load Sub-Block# 3 Load Sub-block Name: Group3 Maximum Load Case Multiplier Load Case ID 4.7420 Uniform Stress 29.0030 Linear Stress Minimum Load Case Multiplier Load Case ID 27.8790 Linear Stress Growth Law: ASMEAusteniticAir Cycles/Time: 8000 Temperature: 653 Cale. Interval: 1 Print Interval: 4000 Load Sub-Block# 4 Load Sub-block Name: Group4 Maximum Load Case Multiplier Load Case ID 4.7420 Uniform Stress 28.0080 Linear Stress Minimum Load Case Multiplier Load Case ID 27.7100 Linear Stress Growth Law: ASMEAusteniticAir Cycles/Time: 400 Temperature: 653 Cale. Interval: 1 Print Interval: 200 Load Sub-Block# 5 Load Sub-block Name: Group5 Maximum Load Case Multiplier Load Case ID 4.7840 Uniform Stress 25.7280 Linear Stress Minimum Load Case Multiplier Load Case ID 4.7000 Uniform Stress L-2018-174 Attachment 19 Enclosure 1 Page 48 of73 File No.: 0901350.304 Page A-27 of A-52 Revision: 3 F0306-0IR1

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 SJ Structural Integrity Associates, Inc.

24.4750 Linear Stress Growth Law: ASMEAusteniticAir Cycles/Time: 6300000 Temperature: 653 Cale. Interval: 1 Print Interval: 65535 Load Sub-Block# 6 Load Sub-block Name: Group6 Maximum Load Case Multiplier Load Case ID 4.7420 Uniform Stress 32.2150 Linear Stress Minimum Load Case Multiplier Load Case ID 27.6200 Linear Stress Growth Law: ASMEAusteniticAir Cycles/Time: 160 Temperature: 653 Cale. Interval: 1 Print Interval: 80 Load Sub-Block# 7 Load Sub-block Name: Group7 Maximum Load Case Multiplier Load Case ID 4.7420 Uniform Stress 30.7970 Linear Stress Minimum Load Case Multiplier Load Case ID 27.7290 Linear Stress Growth Law: ASMEAusteniticAir Cycles/Time: 80 Temperature: 653 Cale. Interval: 1 Print Interval: 40 Load Sub-Block# 8 Load Sub-block Name: Groups Maximum Load Case Multiplier Load Case ID 4.7420 Uniform Stress 27.8240 Linear Stress Minimum Load Case Multiplier Load Case ID 27.5790 Linear Stress Growth Law: ASMEAusteniticAir Cycles/Time: 160 Temperature: 653 Cale. Interval: 1 Print Interval: 80 Load Sub-Block# 9 Load Sub-block Name: Group9 Maximum Load Case Multiplier Load Case ID 4.7420 Uniform Stress 29.5010 Linear Stress Minimum Load Case Multiplier Load Case ID 20.9340 Linear Stress Growth Law: ASMEAusteniticAir Cycles/Time: 800 Temperature: 653 Cale. Interval: 1 File No.: 0901350.304 Revision: 3 L-2018-174 Attachment 19 Enclosure 1 Page 49 of73 Page A-28 of A-52 F0306-01Rl

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

Print Interval: 400 Load Sub-Block# 10 Load Sub-block Name: GrouplO Maximum Load Case Multiplier Load Case ID 4.7420 Uniform Stress 28.5830 Linear Stress Minimum Load Case Multiplier Load Case ID 29.3880 Linear Stress Growth Law: ASMEAusteniticAir Cycles/Time: 20 Temperature: 653 Cale. Interval: 1 Print Interval: 10 Load Sub-Block# 11 Load Sub-block Name: Groupll Maximum Load Case Multiplier Load Case ID 4.7420 Uniform Stress 29.2730 Linear Stress Minimum Load Case Multiplier Load Case ID 22.2520 Linear Stress Growth Law: ASMEAusteniticAir Cycles/Time: 100 Temperature: 653 Cale. Interval: 1 Print Interval: 50 Load Sub-Block# 12 Load Sub-block Name: Group12 Maximum Load Case Multiplier Load Case ID 4.7420 Uniform Stress 28.1210 Linear Stress M'inimum Load Case Multiplier Load Case ID 29.4300 Linear Stress Growth Law: ASMEAusteniticAir Cycles/Time: 16400 Temperature: 653 Cale. Interval: 1 Print Interval: 13200 Load Sub-Block# 13 Load Sub-block Name: Group13 Maximum Load Case Multiplier Load Case ID 4.7420 Uniform Stress 23.6960 Linear Stress Minimum.

Load Case Multiplier Load Case ID 10.1010 Linear Stress Growth Law: ASMEAusteniticAir Cycles/Time: 400 Temperature: 653 Cale. Interval: 1 Print Interval: 200 Load Sub-Block# 14 Load Sub-block Name: Group14 File No.: 0901350.304 Revision: 3 L-2018-174 Attachment 19 Enclosure 1 Page 50 of73 Page A-29 of A-52 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

Maximum Load Case Multiplier Load Case ID 4.7420 Uniform Stress 15.8300 Linear Stress Minimum Load Case Multiplier Load Case ID 18.2800 Linear Stress Growth Law: ASMEAusteniticAir Cycles/Time: 20 Temperature: 653 Cale. Interval: 1 Print Interval: 10 Load Sub-Block# 15 Load Sub-block Name: Group15 Maximum Load Case Multiplier Load Case ID 6.5480 Uniform Stress 21.5900 Linear Stress Minimum Load Case Multiplier Load Case ID 18.2800 Linear Stress Growth Law: ASMEAusteniticAir Cycles/Time: 10 Temperature: 653 Cale. Interval: 1 Print Interval: 5 Load Sub-Block# 16 Load Sub-block Name: Groupl6 Maximum Load Case Multiplier Load Case ID 5.2370 Uniform Stress 21.1880 Linear Stress Minimum Load Case Multiplier Load Case ID 18.2800 Linear Stress Growth Law: ASMEAusteniticAir Cycles/Time: 100 Temperature: 653 Cale. Interval: 1 Print Interval: 50 Material: l Sample Material 1: Only a sample Austenitic Stainless Steel in Air environment (U.S. Customary Units)

The Fatigue Crack Growth Rate (in/cycle) is given by:

da/dN = Co*(Delta K)An where Delta K = Kmax -

Kmin n = the slope of the log (da/dN) versus log (Delta K) 3.3 Co= a scaling constant Co C*S C is given by:

File No.: 0901350.304 Revision: 3 L-2018-174Attachment 19 Enclosure 1 Page 51 of 73 Page A-30 of A-52 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

Tis the metal temperature in deg F Sis a scaling parameter to account for R ratio and is given by:

s

1. 0 for R <= 0 1.0 + 1.8
  • R for O < R <= 0.79

-43.35 + 57.97

  • R for 0.79 < R < 1 where R = Kmin / Kmax No. of Data in the KIC Table= 1 Crack Depth 0.0000 messages/Warnings:

KIC 135.0000 Solution for Ri/t of 0.2 and 0.5 will be used Number of Warnings in Inputs: 0 ANALYSIS RESOLTS -

STRESS INTENSITY FACTORS Load Case# 1: Oniform Stress


Crack Dimensions ------------

Kat tips a

C a/t c/a a

C c/a =

5.0000 0.1406 0.7030 0.1250 5.0000 0.6981 0.3496 0.2406 1.2030 0.2139 5.0000 0.9394 0.4683 0.3406

1. 7030 0.3028 5.0000 1.1743 0.5787 0.4406 2.2030 0.3916 5.0000
1. 4001 0.6825 0.5406 2.7030 0.4805 5.0000
1. 64 79 0.7948 0.6406 3.2030 0.5694 5.0000
1. 9023 0.9087 0.7406 3.7030 0.6583 5.0000 2.2139 1.0377 0.8406 4.2030 0.7472 5.0000
2. 5672 1.1779 c/a =

10.0000 0.1406 1.4060 0.1250 10.0000 0.7347 0.2653 0.2406 2.4060 0.2139 10.0000 1.0038 0.3546 0.3406

3. 40 60 0.3028 10.0000
1. 27 69 0.4350 0.4406 4.4060 0.3916 10.0000
1. 5462 0.5095 0.5406 5.4060 0.4805 10.0000 1.8603 0.5854 0.6406 6.4060 0.5694 10.0000 2.1907 0.6607 0.7406 7.4060 0.6583 10.0000 2.6105 0.7421 0.8406 8.4060 0.7472 10.0000 3.0960 0.8281 c/a =

15.0000 0.1406 2.1090 0.1250 15.0000 0.7461 0.2260 0.2406 3.6090 0.2139 15.0000

1. 02 67 0.3013 0.3406 5.1090 0.3028 15.0000 1.3154 0.3675 0.4406 6.6090 0.3916 15.0000
1. 6028 0.4281 0.5406 8.1090 0.4805 15.0000
1. 9478 0.4854 0.6406 9.6090 0.5694 15.0000 2.3142 0.5405 0.7406" 11.1090 0.6583 15.0000 2.7708 0.5950 0.8406 12.6090 0.7472 15.0000 3.2945 0.6490 c/a 20.0000 File No.: 0901350.304 Revision: 3 L-2018-17 4 Attachment 19 Enclosure 1 Page 52 of 73 Page A-31 of A-52 F0306-01Rl

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

0.1406 2.8120 0.1250 0.2406 4.8120 0.2139 0.3406 6.8120 0.3028 0.4406 8.8120 0.3916 0.5406 10.8120 0.4805 0.6406 12.8120 0.5694 0.7406 14.8120 0.6583 0.8406

16. 8120 0.7472 Load Case# 2: Linear Stress

Crack Dimensions a

C a/t c/a =

5.0000 0.1406 0.7030 0.1250 0.2406 1.2030 0.2139 0.3406 1.7030 0.3028 0.4406 2.2030 0.3916 0.5406 2.7030 0.4805 0.6406 3.2030 0.5694 0.7406 3.7030 0.6583 0.8406 4.2030 0.7472 c/a =

10.0000 0.1406

1. 40 60 0.1250 0.2406 2.4060 0.2139 0.3406 3.4060 0.3028 0.4406 4.4060 0.3916 0.5406 5.4060 0.4805 0.6406 6.4060 0.5694 0.7406 7.4060 0.6583 0.8406 8.4060 0.7472 c/a =

15.0000 0.1406 2.1090 0.1250 0.2406 3.6090 0.2139 0.3406 5.1090 0.3028 0.4406 6.6090 0.3916 0.5406 8.1090 0.4805 0.6406 9.6090 0.5694 0.7406 11.1090 0.6583 0.8406 12.6090 0.7472 c/a =

20.0000 0.1406 2.8120 0.1250 0.2406 4.8120 0.2139 0.3406 6.8120 0.3028 0.4406 8.8120 0.3916 0.5406 10.8120 0.4805 0.6406 12.8120 0.5694 0.7406 14.8120 0.6583 0.8406 16.8120 0.7472 CRACK GROWTH ANALYSIS RESULTS Total Cycles

/Time Blocks:

200.0000 Subblock Cycles

/Time 1

200.0000 File No.: 0901350.304 Revision: 3 Kmax 4.7359 20.0000 20.0000 20.0000 20.0000 20.0000 20.0000 20.0000 20.0000 c/a 5.0000 5.0000 5.0000 5.0000 5.0000 5.0000 5.0000 5.0000 10.0000 10.0000 10.0000 10.0000 10.0000 10.0000 10.0000 10.0000 15.0000 15.0000 15.0000 15.0000 15.0000 15.0000 15.0000 15.0000 20.0000 20.0000 20.0000 20.0000 20.0000 20.0000 20.0000 20.0000 Kmin 0.6076 0.7517 0.1768

1. 0363 0.2357
1. 3296 0.2872
1. 6222 0.3344 1.9735 0.3783 2.3467 0.4204
2. 8122 0.4613 3.3462 0.5013 Kat tips a

0.0601 0.1369 0.2375 0.3595 0.5087

0. 682 9 0.9031 1.170 9
0. 062 6 0.1439
0. 252 8 0.3873 0.5571 0.7595 1.0234 1.3513 0.0634 0.1464
0. 258 6 0.3982 0.5774
0. 7931 1.0739
1. 422 8 0.0638 0.14 7 6 0.2611
0. 402 6 0.5844
0. 8035 1.0892
1. 4445 DeltaK 4.1283 C

5.386E-03 0.0130 0.0243 0.0394 0.0600 0.0858 0.1198 0.1625 2.673E-03 6.589E-03 0.0124 0.0202 0.0305 0.0432 0.0602 0.0817

1. 68 6E-03 4.154E-03
7. 727E-03 0.0124 0.0184 0.0256 0.0341 0.0442
1. 251E-03 3.080E-03 5.712E-03 9.175E-03 0.0135 0.0187 0.0247 0.0316 DaDn

/DaDt 2.791E-08 L-2018-174Attachment 19 Enclosure 1 Page 53 of73 Crack Dimensions a

a/t c

c/a 0.1406 0.1250 Page A-32 of A-52 F0306-0IRI

Turkey Point Units 3 and 4 L-2018-174 Attachment 19 Enclosure 1 Docket Nos. 50-250 and 50-251 Page 54 of73 SJ Structural Integrity Associates, Inc.

1. 7857 0.0544 1.7313 l.359E-09 0.7030 4.9998 400.0000 400.0000 4.7360 0.6076 4.1284 2.791E-08 0.1406 0.1250
1. 7858 0.0544
1. 7314 l.359E-09 0.7030 4.9996
1. 360E+04 l.320E+04 5.0082
1. 77 43 3.2339
1. 659E-08 0.1408 0.1252 1.8127 0.1592
1. 6535 l.282E-09 0.7030 4.9920
1. 680E+04 l.640E+04 5.0097
1. 77 53 3.2344 l.660E-08 0.1409 0.1252
1. 8134 0.1593 1.6541 l.284E-09 0.7030 4.9901 2.080E+04 4000.0000 5.0650 1.6830 3.3819
1. 87 6E-08 0.1410 0.1253 1.8192 0.1511 1.6681 l.310E-09 0.7030 4.9875 2.480E+04 8000.0000 5.0671 1.6843 3.3828
1. 878E-08 0.1410 0.1254 1.8203 0.1514
1. 668 9 l.312E-09 0.7030 4.9849 2.500E+04 200.0000 5.0071
1. 67 42 3.3329
1. 792E-08 0.1410 0.1254
1. 8149 0.1504
1. 6645 l.300E-09 0.7030 4.9848 2.520E+04 400.0000
5. 0072
1. 67 42 3.3329
1. 792E-08 0.1410 0.1254 1.8150 0.1505 1.6645 l.300E-09 0.7030 4.9846 9.074Et04 6.554E+04 4.8988 4.7643 0.1344 3.650E-12 0.1410 0.1254 1.8173
1. 7811 0.0363 4.997E-14 0.7030 4.9846
1. 563E+05
1. 311E+05 4.8988 4.7643 0.1344 3.650E-12 0.1410 0.1254 1.8173
1. 7811 0.0363
4. 997E-14 0.7030 4.9846 2.218E+05 l.966E+05 4.8988 4.7643 0.1344 3.650E-12 0.1410 0.1254 1.8173
1. 7811 0.0363 4.997E-14 0.7030 4.9846 2.873E+05 2.621Et05 4.8988 4.7644 0.1344 3.650E-12 0.1410 0.1254 1.8173 1.7811 0.0363 4.997E-14 0.7030 4.9846 3.529E+05 3.277E+05 4.8988 4.7644 0.1344 3.650E-12 0.1410 0.1254 1.8173
1. 7811 0.0363 4.997E-14 0.7030 4.9846 4.184E+05 3.932E+05 4.8988 4.7644 0.1344 3.650E-12 0.1410 0.1254 1.8173
1. 7811 0.0363 4.997E-14 0.7030 4.9846 4.839E+05 4.587E+05 4.8988 4.7644 0.1344 3.650E-12 0.1410 0.1254 1.8173
1. 7811 0.0363 4.997E-14 0.7030 4.9846 5.495E+05 5.243E+05 4.8988 4.7644 0.1344 3.650E-12 0.1410 0.1254 1.8173
1. 7811 0.0363 4.997E-14 0.7030 4.9846 6.150E+05 5.898E+05 4.8988 4.7644 0.1344 3.650E-12 0.1410 0.1254 1.8174
1. 7811 0.0363 4.997E-14 0.7030 4.9846 6.806E+05 6.554E+05 4.8988 4.7644 0.1344 3.650E-12 0.1410 0.1254 1.8174
1. 7811 0.0363 4.997E-14 0.7030 4.9845 7.461E+05 7.209E+05 4.8988 4.7644 0.1344 3.651E-12 0.1410 0.1254 1.8174
1. 7811 0.0363 4.997E-14 0.7030 4.9845 8.116E+05 7.864E+05 4.8988 4.7644 0.1344 3.651E-12 0.1410 0.1254 1.8174
1. 7811 0.0363 4.997E-14 0.7030 4.9845
8. 772E+05 8.520E+05 4.8988 4.7644 0.1344 3.651E-12 0.1410 0.1254 1.8174
1. 7811 0.0363 4.997E-14 0.7030 4.9845 9.427E+05 9.175E+05 4.8988 4.7644 0.1344 3.651E-12 0.1410 0.1254 1.8174
1. 7811 0.0363 4.997E-14 0.7030 4.9845
1. 008E+06 9.830E+05 4.8989
4. 7 644 0.1344 3.651E-12 0.1410 0.1254
1. 8174 1.7811 0.0363 4.997E-14 0.7030 4.9845 1.074E+06
1. 049E+06 4.8989 4.7644 0.1344 3.651E-12 0.1410 0.1254
1. 8174
1. 7811 0.0363 4.997E-14 0.7030 4.9845 l.139E+06 1.114Et06 4.8989 4.7644 0.1344 3.651E-12 0.1410 0.1254 1.8174
1. 7811 0.0363 4.997E-14 0.7030 4.9845 l.205E+06 l.180E+06 4.8989 4.7644 0.1344 3.651E-12 0.1410 0.1254 1.8174
1. 7811 0.0363
4. 997E-14 0.7030 4.9845 1.270E+06 1.245E+06 4.8989 4.7644 0.1344 3.651E-12 0.1410 0.1254 1.8174 1.7811 0.0363
4. 997E-14 0.7030 4.9845 l.336E+06 1.311Et06 4.8989 4.7645 0.1344 3.651E-12 0.1410 0.1254 1.8174 1.7811 0.0363

. 4. 997E-14 0.7030 4.9845

1. 401E+06 1.376E+06 4.8989 4.7645 0.1344 3.651E-12 0.1410 0.1254 1.8174
1. 7811 0.0363 4.997E-14 0.7030 4.9844
1. 467E+06 l.442E+06 4.8989 4.7645 0.1344 3.651E-12 0.1410 0.1254 1.8174
1. 7811 0.0363 4.997E-14 0.7030 4.9844 l.533E+06 l.507E+06 4.8989 4.7645 0.1344 3.651E-12 0.1410 0.1254 1.8174
1. 7811 0.0363 4.997E-14 0.7030 4.9844 l.598E+06 1.573E+06 4.8989 4.7645 0.1344 3.651E-12 0.1410 0.1254 1.8174
1. 7811 0.0363
4. 997E-14 0.7030 4.9844
1. 664E+06
1. 638E+06 4.8989 4.7645 0.1344 3.651E-12 0.1410 0.1254 1.8174
1. 7811 0.0363 4.997E-14 0.7030 4.9844
1. 729E+06
1. 704E+06 4.8989 4.7645 0.1344 3.651E-12 0.1410 0.1254 1.8174
1. 7811 0.0363 4.997E-14 0.7030 4.9844
1. 795E+06
1. 769E+06 4.8989 4.7645 0.1344 3.651E-12 0.1410 0.1254
1. 8174 1.7811 0.0363 4.998E-14 0.7030 4.9844 File No.: 0901350.304 Page A-33 of A-52 Revision: 3 F0306-0IRI

Turkey Point Units 3 and 4 L-2018-174 Attachment 19 Enclosure 1 Docket Nos. 50-250 and 50-251 Page 55 of73 I)

Structural Integrity Associates, Inc.

1. 860E+06
1. 835E+06 4.8989 4.7645 0.1344 3.651E-12 0.1410 0.1254 1.8174
1. 7812 0.0363 4.998E-14 0.7030 4.9844
1. 926E+06 l.901E+06 4.8989 4.7645 0.1344 3.651E-12 0.1410 0.1254 1.8174
1. 7812 0.0363 4.998E-14 0.7030 4.9844
1. 991E+06
1. 966E+06 4.8989 4.7645 0.1344 3.651E-12 0.1410 0.1254 1.8174
1. 7812 0.0363 4.998E-14 0.7030 4.9844 2.057E+06 2.032E+06 4.8990 4.7645 0.1344
3. 651E-12 0.1410 0.1254 1.8174
1. 7812 0.0363 4;998E-14 0.7030 4.9844 2.122E+06 2.097E+06 4.8990 4.7645 0.1344 3.651E-12 0.1410 0.1254 1.8174
1. 7812 0.0363 4.998E-14 0.7030 4.9844 2.188E+06 2.163E+06 4.8990 4.7645 0.1344
3. 651E-12 0.1410 0.1254 1.8174
1. 7812 0.0363 4.998E-14 0.7030 4.9843 2.253E+06 2.228E+06 4.8990 4.7645 0.1344 3.651E-12 0.1410 0.1254 1.8174
1. 7812 0.0363 4.998E-14 0.7030 4.9843 2.319E+06 2.294E+06 4.8990 4.7645 0.1344 3.651E-12 0.1410 0.1254 1.8174
1. 7812 0.0363 4.998E-14 0.7030 4.9843 2.384E+06 2.359E+06 4.8990 4.7645 0.1344 3.651E-12 0.1410 0.1254 1.8174
1. 7812 0.0363 4.998E-14 0.7030 4.9843 2.450E+06 2.425E+06 4.8990 4.7646 0.1344 3.651E-12 0.1410 0.1254 1.8174
1. 7812 0.0363 4.998E-14 0.7030 4.9843 2.516E+06 2.490E+06 4.8990 4.7646 0.1344 3.651E-12 0.1410 0.1254 1.8174 1.7812 0.0363 4.998E-14 0.7030 4.9843 2.581E+06 2.556E+06 4.8990 4.7646 0.1344
3. 651E-12 0.1410 0.1254 1.8175
1. 7812 0.0363 4.998E-14 0.7030 4.9843 2.647E+06 2.621E+06 4.8990 4.7646 0.1344
3. 651E-12 0.1410 0.1254
1. 8175
1. 7812 0.0363 4.998E-14 0.7030 4.9843 2.712E+06 2.687E+06 4.8990 4.7646 0.1344 3.651E-12 0.1410 0.1254
1. 8175
1. 7812 0.0363 4.998E-14 0.7030 4.9843 2.778E+06 2.752E+06 4.8990 4.7646 0.1344 3.651E-12 0.1411 0.1254 1.8175
1. 7812 0.0363 4.998E-14 0.7030 4.9843 2.843E+06 2.818E+06 4.8990 4.7646 0.1344 3.651E-12 0.1411 0.1254 1.8175
1. 7812 0.0363 4.998E-14 0.7030 4.9843 2.909E+06 2.884E+06 4.8990 4.7646 0.1344 3.651E-12 0.1411 0.1254 1.8175
1. 7812 0.0363 4.998E-14 0.7030 4.9843 2.974E+06 2.949E+06 4.8990 4.7646 0.1344 3.651E-12 0.1411 0.1254 1.8175
1. 7812 0.0363 4.998E-14 0.7030 4.9842 3.040E+06 3.015E+06 4.8990 4.7646 0.1344
3. 651E-12 0.1411 0.1254 1.8175
1. 7812 0.0363 4.998E-14 0.7030 4.9842 3.105E+06 3.080E+06 4.8990 4.7646 0.1344 3.651E-12 0.1411 0.1254 1.8175
1. 7812 0.0363 4.998E-14 0.7030 4.9842
3. l 71E+06 3.146E+06 4.8991 4.7646 0.1344 3.651E-12 0.1411 0.1254
1. 8175
1. 7812 0.0363 4.998E-14 0.7030 4.9842 3.236E+06 3.211E+06 4.8991 4.7646 0.1344 3.651E-12 0.1411 0.1254 1.8175
1. 7812 0.0363 4.998E-14 0.7030 4.9842 3.302E+06 3.277E+06 4.8991 4.7646 0.1344 3.651E-12 0.1411 0.1254
1. 8175
1. 7812 0.0363 4.998E-14 0.7030 4.9842 3.367E+06 3.342E+06 4.8991 4.7646 0.1344 3.651E-12 0.1411 0.1254
1. 8175
1. 7812 0.0363 4.998E-14 0.7030 4.9842 3.433E+06 3.408E+06 4.8991 4.7646 0.1344 3.651E-12 0.1411 0.1254
1. 8175
1. 7812 0.0363 4.998E-14 0.7030 4.9842 3.499E+06 3.473E+06 4.8991 4.7646 0.1344
3. 651E-12 0.1411 0.1254 1.8175
1. 7812
0. 0363 4.998E-14 0.7030 4.9842 3.564E+06 3.539E+06 4.8991 4.7647 0.1344 3.651E-12 0.1411 0.1254 1.8175
1. 7812 0.0363 4.998E-14 0.7030 4.9842 3.630E+06 3.604E+06 4.8991 4.7647 0.1344 3.651E-12 0.1411 0.1254 1.8175
1. 7812 0.0363 4.998E-14 0.7030 4.9842 3.695E+06 3.670E+06 4.8991 4.7647 0.1344 3.651E-12 0.1411 0.1254 1.8175
1. 7812 0.0363 4.999E-14 0.7030 4.9842 3.761E+06 3.735E+06 4.8991 4.7647 0.1344 3.651E-12 0.1411 0.1254 1.8175
1. 7812 0.0363 4.999E-14 0.7030 4.9841 3.826E+06 3.801E+06 4.8991 4.7647 0.1344' 3.651E-12 0.1411 0.1254 1.8175
1. 7812 0.0363 4.999E-14 0.7030 4.9841 3.892E+06 3.867E+06 4.8991 4.7647 0.1344 3.651E-12 0.1411 0.1254 1.8175
1. 7813 0.0363 4.999E-14 0.7030 4.9841 3.957E+06 3.932E+06 4.8991 4.7647 0.1344 3.651E-12 0.1411 0.1254
1. 8175
1. 7813 0.0363 4.999E-14 0.7030 4.9841 4.023E+06 3.998E+06 4.8991 4.7647 0.1344 3.652E-12 0.1411 0.1254
1. 8175
1. 7813 0.0363 4.999E-14 0.7030 4.9841 4.088E+06 4.063E+06 4.8991 4.7647 0.1344 3.652E-12 0.1411 0.1254 File No.: 0901350.304 Page A-34 of A-52 Revision: 3 F0306-0IRI

Turkey Point Units 3 and 4 L-2018-174 Attachment 19 Enclosure 1 Docket Nos. 50-250 and 50-251 Page 56 of73 e

Structural Integrity Associates, Inc.

1.8175

1. 7813 0.0363 4.999E-14 0.7030 4.9841 4.154E+06 4.129E+06 4.8991 4.7647 0.1344 3.652E-12 0.1411 0.1254
1. 8175
1. 7813 0.0363 4.999E-14 0.7030 4.9841 4.219E+06 4.194E+06 4.8992 4.7647 0.1344 3.652E-12 0.1411 0.1254
1. 8175
1. 7813 0.0363 4.999E-14 0.7030 4.9841 4.285E+06 4.260E+06 4.8992 4.7647 0.1344 3.652E-12 0.1411 0.1254
1. 8175
1. 7813 0.0363 4.999E-14 0.7030 4.9841 4.351E+06 4.325E+06 4.8992 4.7647 0.1344 3.652E-12 0.1411 0.1254
1. 8175
1. 7813 0.0363 4.999E-14 0.7030 4.9841 4.416E+06 4.391E+06 4.8992 4.7647 0.1344 3.652E-12 0.1411 0.1254 1.8175 1.7813 0.0363 4.999E-14 0.7030 4.9841 4.482E+06 4.456E+06 4.8992 4.7647 0.1344 3.652E-12 0.1411 0.1254 1.8175
1. 7813 0.0363 4.999E-14 0.7030 4.9841 4.547E+06 4.522E+06 4.8992 4.7647 0.1344 3.652E-12 0.1411 0.1254 1.8176
1. 7813 0.0363 4.999E-14 0.7030 4.9840 4.613E+06 4.587E+06 4.8992 4.7648 0.1344 3.652E-12 0.1411 0.1254 1.8176
1. 7813 0.0363 4.999E-14 0.7030 4.9840 4.678E+06 4.653E+06 4.8992 4.7648 0.1344 3.652E-12 0.1411 0.1254 1.8176
1. 7813 0.0363 4.999E-14 0.7030 4.9840 4.744E+06 4.719E+06 4.8992 4.7648 0.1344 3.652E-12 0.1411 0.1254 1.8176
1. 7813 0.0363 4.999E-14 0.7030 4.9840 4.809E+06 4.784E+06 4.8992 4.7648 0.1344 3.652E-12 0.1411 0.1254 1.8176
1. 7813 0.0363 4.999E-14 0.7030 4.9840 4.875E+06 4.850E+06 4.8992 4.7648 0.1344 3.652E-12 0.1411 0.1254 1.8176
1. 7813 0.0363 4.999E-14 0.7030 4.9840 4.940E+06 4.915E+06 4.8992 4.7648 0.1344 3.652E-12 0.1411 0.1254 1.8176
1. 7813 0.0363 4.999E-14 0.7030 4.9840 5.006E+06 4.981E+06 4.8992 4.7648 0.1344 3.652E-12 0.1411 0.1254 1.8176
1. 7813 0.0363 4.999E-14 0.7030 4.9840 5.071E+06 5.046E+06 4.8992 4.7648 0.. 13 4 4 3.652E-12 0.1411 0.1254 1.8176
1. 7813 0.0363 4.999E-14 0.7030 4.9840 5.137E+06 5.112E+06 4.8992 4.7648 0.1344 3.652E-12 0.1411 0.1254 1.8176
1. 7813 0.0363 4.999E-14 0.7030 4.9840 5.202E+06 5.177E+06 4.8992 4.7648 0.1344 3.652E-12 0.1411 0.1254 1.8176
1. 7813 0.0363 4.999E-14 0.7030 4.9840 5.268E+06 5.243E+06 4.8993 4.7648 0.1344 3.652E-12 0.1411 0.1254 1.8176
1. 7813 0.0363 4.999E-14 0.7030 4.9840 5.334E+06 5.308E+06 4.8993 4.7648 0.1344 3.652E-12 0.1411 0.1254 1.8176
1. 7813 0.0363 4.999E-14 0.7030 4.9839 5.399E+06 5.374E+06 4.8993 4.7648 0.1344 3.652E-12 0.1411 0.1254 1.8176
1. 7813 0.0363 4.999E-14 0.7030 4.9839 5.465E+06 5.439E+06 4.8993 4.7648 0.1344 3.652E-12 0.1411 0.1254 1.8176
1. 7813 0.0363 4.999E-14 0.7030 4.9839 5.530E+06 5.505E+06 4.8993 4.7648 0.1344 3.652E-12 0.1411 0.1254 1.8176
1. 7813 0.0363 4.999E-14 0.7030 4.9839 5.596E+06 5.570E+06 4.8993 4.7648 0.1344 3.652E-12 0.1411 0.1254 1.8176
1. 7813 0.0363 5.000E-14 0.7030 4.9839 5.661E+06 5.636E+06 4.8993 4.7648 0.1344 3.652E-12 0.1411 0.1254 1.8176
1. 7813 0.0363 5.000E-14 0.7030 4.9839
5. 727E+06 5.702E+06 4.8993 4.7649 0.1344 3.652E-12 0.1411 0.1254 1.8176
1. 7813 0.0363 5.000E-14 0.7030 4.9839 5.792E+06 5.767E+06 4.8993 4.7649 0.1344 3.652E-12 0.1411 0.1254 1.8176
1. 7813 0.0363 5.000E-14 0.7030 4.9839 5.858E+06 5.833E+06 4.8993 4.7649 0.1344 3.652E-12 0.1411 0.1254 1.8176
1. 7813 0.0363 5.000E-14 0.7030 4.9839 5.923E+06 5.898E+06 4.8993 4.7649 0.1344 3.652E-12 0.1411 0.1254 1.8176
1. 7814 0.0363 5.000E-14 0.7030 4.9839 5.989E+06 5.964E+06 4.8993 4.7649 0.1344 3.652E-12 0.1411 0.1254 1.8176
1. 7814 0.0363 5.000E-14 0.7030 4.9839 6.054E+06 6.029E+06 4.8993 4.7649 0.1344 3.652E-12 0.1411 0.1254 1.8176
1. 7814 0.0363 5.000E-14 0.7030 4.9839 6.120E+06 6.095E+06 4.8993 4.7649 0.1344 3.652E-12 0.1411 0.1254 1.8176
1. 7814 0.0363 5.000E-14 0.7030 4.9838 6.185E+06 6.160E+06 4.8993 4.7649 0.1344 3.652E-12 0.1411 0.1254 1.8176
1. 7814 0.0363 5.000E-14 0.7030 4.9838 6.251E+06 6.226E+06 4.8993 4.7649 0.1344 3.652E-12 0.1411 0.1254 1.8176
1. 7814 0.0363 5.000E-14 0.7030 4.9838 6.317E+06 6.291E+06 4.8994
4. 7 649 0.1344 3.652E-12 0.1411 0.1254 1.8176
1. 7814 0.0363 5.000E-14 0.7030 4.9838 File No.: 0901350.304 Page A-35 of A-52 Revision: 3 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 SJ Structural Integrity Associates, Inc.

6.325E+06 6.300E+06 4.8994 1.8176 6.325E+06 80.0000

5. 2621 1.8382 6.325E+06 160.0000
5. 2621 1.8382 6.325E+06 40.0000 5.1765 1.8305 6.325E+06 80.0000 5.1765
1. 8305 6.326E+06 80.0000 4.9968 1.8144 6.326E+06 160.0000 4.9969 1.8144 6.326E+06 400.0000 5.0985 1.8237 6.326E+06 800.0000 5.0988
1. 8238 6.326E+06 10.0000 5.0433
1. 8188 6.326E+06 20.0000 5.0433
1. 8188 6.326E+06 50.0000 5.0851 1.8226 6.327E+06 100.0000 5.0851 1.8226 6.340E+06 l.320E+04 5.0215
1. 8194 6.343E+06 l.640E+04 5.0230 1.8201 6.343E+06 200.0000 4.7548
1. 7 960 6.343E+06 400.0000 4.7550
1. 7961 6.343E+06 10.0000 4.2781
1. 7 532 6.343E+06 20.0000 4.2781
1. 7 532 6.343E+06 5.0000 5.8911 2.4194 6.343E+06 10.0000 5.8911 2.4194 6.343E+06 50.0000 4.9494 1.9564 6.343E+06 100.0000 4.9494 1.9564 Maximum number of blocks reached. The Number of Runtime Warnings: 0
      • End of pc-CRACK output***

File No.: 0901350.304 Revision: 3 4.7649 0.1344

1. 7814 0.0363 1.6692
3. 592 9 0.1500
1. 6881 1.6692 3.5929 0.1500 1.6882
1. 67 58 3.5006 0.1506
1. 6799
1. 67 59 3.5006 0.1506
1. 6799
1. 6668 3.3300 0.1498 1.6646
1. 6668 3.3300 0.1498 1.6646 1.2654 3.8332 0.1137
1. 7099 1.2655 3.8333 0.1138
1. 7100
1. 77 66 3.2668 0.1597
1. 6591
1. 77 66 3.2668 0.1597
1. 6591 1.3452 3.7399 0.1209 1.7017 1.3452 3.7399 0.1209 1.7017
1. 7831 3.2384 0.1606
1. 658 8
1. 7841 3.2389 0.1607 1.6594 0.6124 4.1425 0.0552
1. 7409 0.6124 4.1426 0.0552
1. 7409 1.1083 3.1698 0.0999
1. 6533 1.1083 3.1698 0.0999
1. 6533 1.1083
4. 7828 0.0999 2.3195 1.1083
4. 7828 0.0999 2.3195 1.1083
3. 8411 0.0999 1.8566 1.1083 3.8411 0.0999
1. 8566 analysis terminated.

L-2018-174 Attachment 19 Enclosure 1 Page 57 of 73 3.652E-12 0.1411 0.1254 5.000E-14 0.7030 4.9838 2.252E-08 0.1411 0.1254 l.360E-09 0.7030 4.9838 2.252E-08

0. 1411 0.1254 l.360E-09 0.7030 4.9837 2.082E-08 0.1411 0.1254
1. 339E-09 0.7030 4.9837 2.082E-08 0.1411 0.1254 l.339E-09 0.7030 4.9836 l.785E-08 0.1411 0.1254 l.300E-09 0.7030 4.9836
1. 785E-08 0.1411 0.1254
1. 300E-09 0.7030 4.9835 2.568E-08 0.1411 0.1254 l.375E-09 0.7030 4.9832 2.568E-08 0.1411 0.1254 l.376E-09 0.7030 4.9828
1. 711E-08 0.1411 0.1254 l.296E-09 0.7030 4.9828
1. 711E-08 0.1411 0.1254 l.296E-09 0.7030 4.9828 2.415E-08 0.1411 0.1254
1. 362E-09 0.7030 4.9828 2.415E-08 0.1411 0.1254 l.362E-09 0.7030 4.9827 l.668E-08 0.1413 0.1256
1. 297E-09 0.7031 4.9751
1. 669E-08 0.1414 0.1257
1. 298E-09 0.7031 4.9732 2.824E-08 0.1414 0.1257
1. 385E-09 0.7031 4.9730 2.825E-08 0.1414 0.1257 l.385E-09 0.7031
4. 9728
1. 390E-08 0.1414 0.1257 l.220E-09 0.7031 4.9728
1. 390E-08 0.1414 0.1257
1. 220E-09 0.7031 4.9728 4.932E-08 0.1414 0.1257 3.634E-09 0.7031 4.9728 4.932E-08 0.1414 0.1257 3.634E-09 0.7031 4.9728 2.507E-08 0.1414 0.. 1257
1. 771E-09 0.7031
4. 9728 2.507E-08 0.1414 0.1257
1. 771E-09 0.7031 4.9727 Page A-36 of A-52 F0306-01Rl

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

A.6 SURGE LINE 80 YEARS pc-CRACK 4.1 CS Version Control No. 4.1.0.0 Structural Integrity Associates, Inc.

www.structint.com pccrack@structint.com Date: 05/18/2017 15:04 L-2018-174 Attachment 19 Enclosure 1 Page 58 of73 Input Data read from C:\\Users\\wwong\\Documents\\Projects\\TurkeyPoint - 1700109\\surge.pcf Analysis

Title:

Surge Units Selected: US Customary Linear Dimensions -

inches Stress - ksi Load -

kips Temperature -

deg F Time -

hours Analysis Type: Crack Growth (LEFM)

Crack Growth Calculation Method -

Cycle/Time Stepping Maxinum Number of Load Blocks 1

Block Print Interval= 1 Crack Model: 309-Semi-Elliptical Circumferential Crack in Cylinder on the Inside Surface (Chapuliot)

Crack Depth, a=

0.1406 Half Crack Length, c 0.7030 Wall Thickness, t =

1.1250 Inside Radius, Ri =

5.2500 Aspect ratio allowed to vary Maximum a/t = 0.8 Crack Depth Print Increment for SIF Tabulation= 0.1 Maximum Aspect Ratio (c/a) for SIF Tabulation= 20 Aspect Ratio Increment for SIF Tabulation= 5 Total Load Cases: 2 Load Case l:Uniform Stress Type: Stress Coefficients Input by User Coefficient CO Coefficient Cl Coefficient C2 Coefficient C3

1. 0000 0.0000 0.0000 0.0000 Load Case 2:Linear Stress Type: Stress Coefficients Input by User Coefficient CO Coefficient Cl Coefficient C2 Coefficient C3 0.0000 1.0000 0.0000 0.0000 Total Load Sub-Blocks: 16 Load Sub-Block# 1 Load Sub-block Name: Groupl Maximum Load Case Multiplier Load Case ID File No.: 0901350.304 Page A-37 of A-52 Revision: 3 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

4.7420 Uniform Stress 23.6960 Linear Stress Minimum Load Case Multiplier Load Case ID 10.1010 Linear Stress Growth Law: TableDADN Cycles/Time: 200 Cale. Interval: 1 Print Interval: 200 Load Sub-Block# 2 Load Sub-block Name: Group2 Maximum Load Case Multiplier Load Case ID 4.7420 Uniform Stress 28.1210 Linear Stress Minimum Load Case Multiplier Load Case ID 29.4300 Linear Stress Growth Law: TableDADN Cycles/Time: 13200 Cale. Interval: 1 Print Interval: 13200 Load Sub-Block# 3 Load Sub-block Name: Group3 Maximum Load Case Multiplier Load Case ID 4.7420 Uniform Stress 29.0030 Linear Stress Minimum Load Case Multiplier Load Case ID 27.8790 Linear Stress Growth Law: TableDADN Cycles/Time: 4000 Cale. Interval: 1 Print Interval: 4000 Load Sub-Block# 4 Load Sub-block Name: Group4 Maximum Load Case Multiplier Load Case ID 4.7420 Uniform Stress 28.0080 Linear Stress Minimum Load Case Multiplier Load Case ID 27.7100 Linear Stress Growth Law: TableDADN Cycles/Time: 200 Cale. Interval: 1 Print Interval: 200 Load Sub-Block# 5 Load Sub-block Name: Group5 Maximum Load Case Multiplier Load Case ID 4.7840 Uniform Stress 25.7280 Linear Stress Minimum Load Case Multiplier Load Case ID 4.7000 Uniform Stress 24.4750 Linear Stress Growth Law: TableDADN Cycles/Time: 3150000 Cale. Interval: 1 File No.: 0901350.304 Revision: 3 L-2018-174 Attachment 19 Enclosure 1 Page 59 of 73 Page A-38 of A-52 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

Print Interval: 65535 Load Sub-Block J 6 Load Sub-block Name: Group6 Maximum Load Case Multiplier Load Case ID 4.7420 Uniform Stress 32.2150 Linear Stress Minimum Load Case Multiplier Load Case ID 27.6200 Linear Stress Growth Law: TableDADN Cycles/Time: 80 Cale. Interval: 1 Print Interval: 80 Load Sub-Block J 7 Load Sub-block Name: Group?

Maximum Load Case Multiplier Load Case ID 4.7420 Uniform Stress 30.7970 Linear Stress Minimum Load Case Multiplier Load Case ID 27.7290 Linear Stress Growth Law: TableDADN Cycles/Time: 40 Cale. Interval: 1 Print Interval: 40 Load Sub-Block J 8 Load Sub-block Name: Groups Maximum Load Case Multiplier Load Case ID 4.7420 Uniform Stress 27.8240 Linear Stress Minimum Load Case Multiplier Load Case ID 27.5790 Linear Stress Growth Law: TableDADN Cycles/Time: 80 Cale. Interval: 1 Print Interval: 80 Load Sub-Block J 9 Load Sub-block Name: Group9 Maximum Load Case Multiplier Load Case ID 4.7420 Uniform Stress 29.5010 Linear Stress Minimum Load Case Multiplier Load Case ID 20.9340 Linear Stress Growth Law: TableDADN Cycles/Time: 400 Cale. Interval: 1 Print Interval: 400 Load Sub-Block J 10 Load Sub-block Name: GrouplO Maximum Load Case Multiplier Load Case ID 4.7420 Uniform Stress 28.5830 Linear Stress L-2018-174 Attachment 19 Enclosure 1 Page 60 of73 File No.: 0901350.304 Page A-39 of A-52 Revision: 3 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

Minimum Load Case Multiplier Load Case ID 29.3880 Linear Stress Growth Law: TableDADN Cycles/Time: 10 Cale. Interval: 1 Print Interval: 10 Load Sub-Block# 11 Load Sub-block Name: Groupll Maximum Load Case Multiplier Load Case ID 4.7420 Uniform Stress 29.2730 Linear Stress Minimum Load Case Multiplier Load Case ID 22.2520 Linear Stress Growth Law: TableDADN Cycles/Time: 50 Cale. Interval: 1 Print Interval: 50 Load Sub-Block# 12 Load Sub-block Name: Group12 Maximum Load Case Multiplier Load Case ID 4.7420 Uniform Stress 28.1210 Linear Stress Minimum Load Case Multiplier Load Case ID 29.4300 Linear Stress Growth Law: TableDADN Cycles/Time: 13200 Cale. Interval: 1 Print Interval: 13200 Load Sub-Block #~ 13 Load Sub-block Name: Group13 Maximum Load Case Multiplier Load Case ID 4.7420 Uniform Stress 23.6960 Linear Stress Minimum Load Case Multiplier Load Case ID 10.1010 Linear Stress Growth Law: TableDADN Cycles/Time: 200 Cale. Interval: 1 Print Interval: 200 I

Load Sub-Block# 14 Load Sub-block Name: Group14 Maximum Load Case Multiplier Load Case ID 4.7420 Uniform Stress 15.8300 Linear Stress Minimum Load Case Multiplier Load Case ID 18.2800 Linear Stress Growth Law: TableDADN Cycles/Time: 10 Cale. Interval: 1 Print Interval: 10 Load Sub-Block# 15 File No.: 0901350.304 Revision: 3 L-2018-174Attachment 19 Enclosure 1 Page 61 of 73 Page A-40 of A-52 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

Load Sub-block Name: Group15 Maximum Load Case Multiplier Load Case ID 6.5480 Uniform Stress 21.5900 Linear Stress Minimum Load Case Multiplier Load Case ID 18.2800 Linear Stress Growth Law: TableDADN Cycles/Time: 5 Cale. Interval: 1 Print Interval: 5 Load Sub-Block# 16 Load Sub-block Name: Group16 Maximum Load Case Multiplier Load Case ID 5.2370 Uniform Stress 21.1880 Linear Stress Minimum Load Case Multiplier Load Case ID 18.2800 Linear Stress Growth Law: TableDADN Cycles/Time: 50 Cale. Interval: 1 Print Interval: 50 Material: 1 Sample Material 1: Only a sample Table(da/dn-DK)

No. of R ratios in the tables R Ratio

-100.0000 Delta K da/dn l.OOOE-03 2.410E-14 1.0000 2.410E-14 1.1000

1. 680E-07 10.0000 2.410E-05 20.0000 l.150E-04 30.0000 2.850E-04 40.0000 5.450E-04 50.0000 9.000E-04 60.0000
1. 360E-03 70.0000
1. 920E-03 80.0000 2.590E-03 90.0000 3.380E-03 100.0000 4.280E-03 R Ratio 0.10.00 Delta K da/dri
1. OOOE-03 2.420E-14 1.0000 2.420E-14 1.1000
1. 690E-07 10.0000 2.420E-05 20.0000 1.150E-04 30.0000 2.870E-04 40.0000 5.480E-04 50.0000 9.050E-04 60.0000 l.360E-03 70.0000 l.930E-03 80.0000 2.610E-03 90.0000 3.400E-03 File No.: 0901350.304 Revision: 3 5

L-2018-17 4 Attachment 19 Enclosure 1 Page 62 of73 Page A-41 of A-52 F0306-0IR!

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

100.0000 4.300E-03 R Ratio 0.5000 Delta K da/dn

1. OOOE-03 2.740E-14 1.0000 2.740E-14 1.1000 l.910E-07 10.0000 2.740E-05 20.0000 l.300E-04 30.0000 3.240E-04 40.0000 6.190E-04 50.0000
1. 020E-03 60.0000
1. 540E-03 70.0000 2.180E-03 80.0000 2.950E-03 90.0000 3.840E-03 100.0000 4.870E-03 R Ratio 0.7000 Delta K da/dn l.OOOE-03 4.050E-14 1.0000 4.050E-14 1.1000 2.820E-07 10.0000 4.050E-05 20.0000 l.920E-04 30.0000 4.790E-04 40.0000 9.150E-04 50.0000 l.510E-03 60.0000 2.280E-03 70.0000 3.220E-03 80.0000 4.350E-03 90.0000 5.680E-03 100.0000 7.190E-03 R Ratio 1.0000 Delta K da/dn
1. OOOE-03 2.060E-13 1.0000 2.060E-13 1.1000
1. 430E-06 10.0000 2.060E-04 20.0000 9.780E-04 30.0000 2.440E-03 40.0000 4.650E-03 50.0000 7.690E-03 60.0000 0.0116 70.0000 0.0164 80.0000 0.0221 90.0000 0.0289 100.0000 0.0366 No. of Data in the KIC Table 1

Crack Depth 0.0000 messages/Warnings:

KIC 135.0000 Solution for Ri/t of 0.2 and 0.5 will be used Number of Warnings in Inputs: 0 ANALYSIS RESULTS -

STRESS INTENSITY FACTORS File No.: 0901350.304 Revision: 3 L-2018-174 Attachment 19 Enclosure 1 Page 63 of73 Page A-42 of A-52 F0306-0IR!

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 SJ Structural Integrity Associates, Inc.

Load Case# 1: Uniform Stress


Crack Dimensions a

c a/t c/a =

0.1406 0.2406 0.3406 0.4406 0.5406 0.6406 0.7406 0.8406 c/a =

0.1406 0.2406 0.3406 0.4406 0.5406 0.6406 0.7406 0.8406 c/a =

0.1406 0.2406 0.3406 0.4406 0.5406 0.6406 0.7406 0.8406 c/a =

0.1406 0.2406 0.3406 0.4406 0.5406 0.6406 0.7406 0.8406 5.0000 0.7030 1.2030 1.7030 2.2030 2.7030 3.2030 3.7030 4.2030 10.0000 1.4060 2.4060 3.4060 4.4060 5.4060 6.4060 7.4060 8.4060 15.0000 2.1090 3.6090 5.1090 6.6090 8.1090 9.6090 11.1090

12. 6090 20.0000 2.8120 4.8120 6.8120 8.8120 10.8120 12.8120 14.8120 16.8120 0.1250 0.2139 0.3028 0.3916 0.4805 0.5694 0.6583 0.7472 0.1250 0.2139 0.3028 0.3916 0.4805 0.5694 0.6583 0.7472 0.1250
0. 213 9 0.3028 0.3916 0.4805 0.5694 0.6583 0.7472 0.1250 0.2139 0.3028 0.3916 0.4805 0.5694 0.6583 0.7472 Load Case# 2: Linear Stress c/a 5.0000 5.0000 5.0000 5.0000 5.0000 5.0000 5.0000 5.0000 10.0000 10.0000 10.0000 10.0000 10.0000 10.0000 10.0000 10.0000 15.0000 15.0000 15.0000 15.0000 15.0000 15.0000 15.0000 15.0000 20.0000 20.0000 20.0000 20.0000 20.0000 20.0000 20.0000 20.0000

Crack Dimensions------------

a c

a/t c/a c/a =

0.1406 0.2406 0.3406 0.4406 0.5406 0.6406 0.7406 0.8406 c/a =

0.1406 0.2406 0.3406 0.4406 5.0000 0.7030 1.2030 1.7030 2.2030 2.7030 3.2030 3.7030 4.2030 10.0000 1.4060 2.4060 3.4060 4.4060 File No.: 0901350.304 Revision: 3 0.1250 0.2139 0.3028 0.3916 0.4805

0. 5 694 0.6583 0.7472 0.1250 0.2139 0.3028 0.3916 5.0000 5.0000 5.0000 5.0000 5.0000 5.0000 5.0000 5.0000 10.0000 10.0000 10.0000 10.0000 Kat tips a

0.6981 0.9394 1.1743

1. 4001 1.6479
1. 9023 2.2139
2. 5672 0.7347
1. 0038 1.2769
1. 5462
1. 8 603 2.1907 2.6105 3.0960 0.7461
1. 0267
1. 3154
1. 6028
1. 94 78 2.3142
2. 7708 3.2945 0.7517
1. 0363
1. 3296 1.6222 1.9735 2.3467 2.8122 3.3462 C

0.3496 0.4683 0.5787 0.6825 0.7948 0.9087 1.0377 1.1779 0.2653 0.3546 0.4350 0.5095 0.5854 0.6607 0.7421 0.8281

0. 22 60 0.3013 0.3675 0.4281 0.4854 0.5405 0.5950 0.6490 0.1768 0.2357
0. 2872 0.3344 0.3783 0.4204 0.4613
0. 5013 Kat tips a

C 0.0601 0.1369 0.2375 0.3595 0.5087

0. 682 9 0.9031 1.1709
0. 0 62 6 0.1439 0.2528 0.3873 5.386E-03 0.0130 0.0243 0.0394 0.0600 0.0858 0.1198 0.1625 2.673E-03 6.589E-03 0.0124 0.0202 L-2018-174 Attachment 19 Enclosure 1 Page 64 of73 Page A-43 of A-52 F0306-0IRI

Turkey Point Units 3 and 4 L-2018-174 Attachment 19 Enclosure 1 Docket Nos. 50-250 and 50-251 Page 65 of73 e

Structural Integrity Associates, Inc.

0.5406 5.4060 0.4805 10.0000

0. 5571 0.0305 0.6406 6.4060 0.5694 10.0000 0.7595 0.0432 0.7406 7.4060 0.6583 10.0000
1. 0234 0.0602 0.8406 8.4060 0.7472 10.0000
1. 3513 0.0817 c/a =

15.0000 0.1406 2.1090 0.1250 15.0000

0. 0634
1. 686E-03 0.2406 3.6090 0.2139 15.0000 0.1464 4.154E-03 0.3406 5.1090 0.3028 15.0000 0.2586
7. 727E-03 0.4406 6.6090 0.3916 15.0000 0.3982 0.0124 0.5406 8.1090 0.4805 15.0000 0.5774 0.0184 0.6406 9.6090 0.5694 15.0000 0.7931 0.0256 0.7406 11.1090 0.6583 15.0000 1.0739 0.0341 0.8406
12. 6090 0.7472 15.0000
1. 4228 0.0442 c/a =

20.0000 0.1406 2.8120 0.1250 20.0000 0.0638 l.251E-03 0.2406 4.8120 0.2139 20.0000 0.1476 3.080E-03 0.3406 6.8120 0.3028 20.0000 0.2611 5.712E-03 0.4406 8.8120 0.3916 20.0000

0. 402 6 9.175E-03 0.5406 10.8120 0.4805 20.0000 0.5844
0. 0135 0.6406 12.8120 0.5694 20.0000 0.8035 0.0187 0.7406 14.8120 0.6583 20.0000 1.0892 0.0247 0.8406 16.8120 0.7472 20.0000
1. 4445 0.0316 CRACK GROWTH ANALYSIS RESULTS Total Subblock Cycles Cycles DaDn

/Time

/Time Kmax Kmin DeltaK

/DaDt Crack Dimensions a

a/t C

c/a Blocks:

1 200.000_0 200.0000 4.7522

0. 6117 4.1405 3.361E-06 0.1413 0.1256 1.7946 0.0551
1. 7395 4.737E-07 0.7031 4.9770 l.340E+04 l.320E+04 5.8383 2.3483 3.4900 2.489E-06 0.1713 0.1523 2.2510 0.2613 1.9897 6.441E-07 0.7100 4.1441
1. 740E+04 4000.0000 6.2262 2.4395
3. 78 67 2.981E-06 0.1829 0.1626 2.4187 0.2884 2.1303
7. 517E-07
0. 712 9 3.8981
1. 760E+04 200.0000 6.1546 2.4355
3. 7191 2.866E-06 0.1834 0.1631 2.4152 0.2885 2.1267 7.489E-07
0. 7130 3.8867 8.314E+04 6.554E+04 5.9870
5. 8114 0.1755
1. 758E-13 0.1834 0.1631' 2.4103 2.3596 0.0507 l.839E-13
0. 7130 3.8867
1. 487E+05 l.311E+05 5.9870 5.8114 0.17 55
1. 7 58E-13 0.1834 0.1631 2.4103 2.3596 0.0507 1.839E-13 0.7130 3.8867 2.142E+05 l.966E+05 5.9870 5.8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507 l.839E-13
0. 7130 3.8867 2.797E+05 2.621E+05 5.9870 5.8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507
1. 839E-13
0. 7130 3.8867 3.453E+05 3.277E+05 5.9870 5.8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507
1. 839E-13 0.7130 3.8867 4.108E+05 3.932E+05 5.9870 5.8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507
1. 839E-13 0.7130 3.8867 4.763E+05 4.587E+05 5.9870
5. 8114 0.1755
1. 7 58E-13 0.1834 0.1631 2.4103
2. 3596 0.0507 l.839E-13 0.7130 3.8867 5.419E+05 5.243E+05 5.9870 5.8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507 l.839E-13 0.7130 3.8867 6.074E+05 5.898E+05 5.9870 5.8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507 l.839E-13 0.7130
3. 8 8 67 6.730E+05 6.554E+05 5.9870 5.8114 0.1755
1. 7 58E-13 0.1834 0.1631 2.4103 2.3596 0.0507 1.839E-13
0. 7130 3.8867 7.385E+05 7.209E+05 5.9870 5.8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507
1. 839E-13
0. 7130 3.8867 8.040E+05 7.864E+05 5.9870 5.8114 0.1755
1. 7 58E-13 0.1834 0.1631*

2.4103 2.3596 0.0507 l.839E-13 0.7130 3.8867 File No.: 0901350.304 Page A-44 of A-52 Revision: 3 F0306-01Rl

Turkey Point Units 3 and 4 L-2018-174 Attachment 19 Enclosure 1 Docket Nos. 50-250 and 50-251 Page 66 of73 e

Structural Integrity Associates, Inc.

8.696E+05 8.520E+05 5.9870 5.8114 0.1755

1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507 1.839E-13 0.7130
3. 8 8 67 9.351E+05 9.175E+05 5.9870 5.8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507 l.839E-13
0. 7130
3. 8 8 67
1. 001E+06 9.830E+05 5.9870
5. 8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507 1.839E-13
0. 7130
3. 8 8 67
1. 066E+06 1.049E+06 5.9870
5. 8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507 1.839E-13 0.7130 3.8867 l.132E+06 1.114E+06 5.9870
5. 8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507 1.839E-13
0. 7130 3.8867 l.197E+06 1.180E+06 5.9870
5. 8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507 1.839E-13 0.7130 3.8867 1.263E+06 1.245E+06 5.9870 5.8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507 1.839E-13
0. 7130
3. 8 8 67
1. 328E+06 1.311E+06 5.9870 5.8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507
1. 839E-13 0.7130 3.8867 1.394E+06 1.376E+06 5.9870 5.8114 0.1755
1. 7 58E-13 0.1834 0.1631 2.4103 2.3596 0.0507
1. 839E-13 0.7130 3.8867
1. 459E+06 1.442E+06 5.9870 5.8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507
1. 839E-13 0.7130 3.8867 1.525E+06 1.507E+06 5.9870 5.8114 0.1755
1. 7 58E-13 0.1834 0.1631 2.4103 2.3596 0.0507
1. 839E-13
0. 7130
3. 8 8 67 l.590E+06
1. 573E+06 5.9870 5.8114 0.1755 1.758E-13 0.1834 0.1631 2.4103 2.3596 0.0507
1. 839E-13
0. 7130
3. 8 8 67
1. 656E+06
1. 638E+06 5.9870
5. 8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507
1. 839E-13
0. 7130
3. 8 8 67
1. 722E+06 l.704E+06 5.9870 5.8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507 1.839E-13
0. 7130
3. 8 8 67
1. 787E+06
1. 769E+06 5.9870 5.8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507 l.839E-13 0.7130
3. 8 8 67
1. 853E+06 l.835E+06 5.9870 5.8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507 l.839E-13
0. 7130 3.8867
1. 918E+06
1. 901E+06 5.9870 5.8114 0.1755
1. 7 58E-13 0.1834 0.1631 2.4103 2.3596 0.0507 1.839E-13 0.7130 3.8867
1. 984E+06
1. 966E+06 5.9870
5. 8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507
1. 839E-13 0.7130 3.8867 2.049E+06 2.032E+06 5.9870 5.8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507
1. 839E-13 0.7130 3.8867 2.115E+06 2.097E+06 5.9870
5. 8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507
1. 839E-13 0.7130 3.8867 2.180E+06 2.163E+06 5.9870
5. 8114 0.1755
1. 7 58E-13 0.1834 0.1631 2.4103
2. 3596 0.0507
1. 839E-13 0.7130 3.8867 2.246E+06 2.228E+06 5.9870 5.8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507 1.839E~l3 0.7130
3. 88 67
2. 311E+06 2.294E+06 5.9870 5.8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507
1. 839E-13 0.7130 3.8867 2.377E+06 2.359E+06 5.9870
5. 8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507 1.839E-13 0.7130 3.8867 2.442E+06 2.425E+06 5.9870 5.8114 0.17 55
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507 1.839E-13 0.7130 3.8867 2.508E+06 2.490E+06 5.9870 5.8114 0.17 55
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507 l.839E-13
0. 7130
3. 8 8 67 2.573E+06 2.556E+06 5.9870 5.8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507 1.839E-13
0. 7130 3.8867 2.639E+06 2.621E+06 5.9870 5.8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507 1.839E-13
0. 7130 3.8867 2.705E+06 2.687E+06 5.9870
5. 8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507
1. 839E-13
0. 7130 3.8867 2.770E+06 2.752E+06 5.9870
5. 8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507
1. 839E-13
0. 7130 3.8867 2.836E+06 2.818E+06 5.9870
5. 8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507 l.839E-13
0. 7130 3.8867 2.901E+06 2.884E+06 5.9870
5. 8114 0.1755
1. 7 58E-13 0.1834 0.1631 2.4103 2.3596 0.0507 l.839E-13 0.7130 3.8867
2. 967E+06 2.949E+06 5.9870 5.8114 0.1755
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507 l.839E-13 0.7130 3.8867 3.032E+06 3.015E+06 5.9870 5.8114 0.17 55
1. 758E-13 0.1834 0.1631 2.4103 2.3596 0.0507
1. 839E-13 0.7130 3.8867 3.098E+06 3.080E+06 5.9870 5.8114 0.1755
1. 7 58E-13 0.1834 0.1631 File No.: 0901350.304 Page A-45 of A-52 Revision: 3 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

2.4103 3.163E+06 3.146E+06 5.9870 2.4103 3.168E+o6 3.150E+06 5.9870 2.4103 3.168E+o6 80.0000 6.5328 2.4625 3.168E+06 40.0000 6.4117 2.4493 3.168E+06 80.0000 6.1557 2.4209 3.168E+06 400.0000 6.3506 2.4588 3.168E+06 10.0000 6.2693 2.4493 3.168E+06 50.0000 6.3365 2.4591 3.181E+06

1. 320E+04
7. 2721 2.9151 3.182E+06 200.0000 6.7878 2.8613 3.182E+06 10.0000
5. 8622 2.7350 3.182E+06 5.0000 8.0641
3. 7728 3.182E+06 50.0000
6. 9172 3.0838 Maximum number of blocks reached. The Number of Runtime Warnings: 0
      • End of pc-CRACK output***

File No.: 0901350.304 Revision: 3 2.3596 0.0507 5.8114 0.1755 2.3596 0.0507

5. 8114 0.1755 2.3596 0.0507 2.4329 4.0999 0.2885 2.1740 2.4450
3. 9667 0.2901 2.1592 2.4361
3. 7196 0.2893 2.1317 1.8730 4.4776 0.2238 2.2350 2.6300 3.6393 0.3143 2.1350 1.9943 4.3422 0.2385 2.2206
3. 4363 3.8358 0.4679 2.4472 1.18 93 5.5985 0.1627 2.6986 2.1528 3.7095 0.2945 2.4404 2.1532 5.9109 0.2946 3.4782 2.1566 4.7607 0.2953 2.7885 analysis terminated.

l.839E-13

1. 758E-13 l.839E-13
1. 758E-13 l.839E-13 3.544E-06 7.863E-07 3.299E-06 7.746E-07 2.867E-06 7.528E-07 4.219E-06 8.324E-07 2.750E-06
7. 57 6E-07 3.961E-06 8.204E-07 3.146E-06
1. 040E-06 6.719E-06 l.272E-06 2.825E-06
1. Ol 7E-06 7.811E-06 2.251E-06 4.867E-06 l.369E-06 L-2018-174 Attachment 19 Enclosure 1 Page 67 of73 0.7130 3.8867 0.1834 0.1631 0.7130 3.8867 0.1834 0.1631 0.7130 3.8867 0.1837 0.1633 0.7131 3.8811 0.1839 0.1634 0.7131 3.8785 0.1841 0.1636 0.7132 3.8740 0.1858 0.1651 0.7135 3.8408 0.1858 0.1652 0.7135 3.8402 0.1860 0.1653
0. 713 6 3.8364 0.2244 0.1995
0. 7253 3.2319 0.2258 0.2007
0. 7255 3.2138 0.2258 0.2007
0. 7256 3.2135 0.2258 0.2007
0. 7256 3.2130 0.2261 0.2010
0. 7256 3.2098 Page A-46 of A-52 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

L-2018-174 Attachment 19 Enclosure 1 Page 68 of 73 A.7 ACCUMULATOR LINE THROUGH-WALL CRACK STRESS INTENSITY CALCULATION pc-CRACK 4.2 CS Version Control No. 4.2.0.0 Structural Integrity Associates, Inc.

www.structint.com pccrack@structint.com Date: 10/03/2018 16:09 Input Data read from C: \\Users\\mfong\\Documents\\Turkey *Point LBB\\ACC_TH.pcf Analysis

Title:

Test Problem Units Selected: US Customary Analysis Type: Stress Intensity Factors Crack Model: 311-Through-Wall Circumferential Crack in Cylinder Under Tension And Bending Half Crack Length, a 2.5300 Wall Thickness, t 1.0000 Mean Radius, Rm=

4.8750 Maximum a/(PI*Rm) 0.18 Crack Depth Print Increment for SIF Tabulation 0.01 Total Load Cases: 2 Load Case 1:Max Type: Stress Coefficients Input by User Coefficient CO Coefficient Cl Coefficient C2 Coefficient C3 Load Case 2:Min 19.0200 0.0000 0.0000 0.0000 Type: Stress Coefficients Input by User Coefficient CO Coefficient Cl Coefficient C2 Coefficient C3 messages/Warnings:

-9.1400 0.0000 0.0000 0.0000 Number of Warnings in Inputs: 0 ANALYSIS RESULTS -

STRESS INTENSITY FACTORS Load Case # 1: Max a

a/(PI*Rm) 2.5300 0.1652 2.5400 0.1658 2.5500 0.1665 2.5600 0.1672 2.5700 0.1678 File No.: 0901350.304 Revision: 3 69.0941 69.3408 69.5879 69.8354 70.0833 K

Page A-47 of A-52 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

2.5800 0.1685 70.3318 2.5900 0.1691 70.5806 2.6000 0.1698 70.8299 2.6100 0.1704

71. 0796 2.6200 0.1711
71. 3298 2.6300 0.1717
71. 5805 2.6400 0.1724
71. 8315 2.6500 0.1730 72.0831 2.6600 0.1737
72. 3351 2.6700 0.1743 72.5875 2.6800 0.1750 72.8404 2.6900 0.1756 73.0938 2.7000 0.1763 73.3476
2. 7100 0.17 69 73.6019
2. 7200 0.1776 73.8567 2.7300 0.1783 74.1119 2.7400 0.1789 74.3676 2.7500 0.1796 74.6238 Load Case # 2: Min a

a/ (PI*Rm) 2.5300 0.1652

-33.2030 2.5400 0.1658

-33.3215 2.5500 0.1665

-33.4402 2.5600 0.1672

-33.5592 2.5700 0.1678

-33.6783 2.5800 0.1685

-33.7977 2.5900 0.1691

-33.9173 2.6000 0.1698

-34.0371 2.6100 0.1704

-34.1571 2.6200 0.1711

-34.2773 2.6300 0.1717

-34.3978 2.6400 0.1724

-34.5184 2.6500 0.1730

-34.6393 2.6600 0.1737

-34.7604 2.6700 0.17 43

-34.8817 2.6800 0.1750

-35.0032 2.6900 0.1756

-35.1250 2.7000 0.17 63

-35.2470

2. 7100 0.1769

-35.3692

2. 7200 0.1776

-35.4916 2.7300 0.1783

-35.6142 2.7400 0.1789

-35.7371 2.7500 0.1796

-35.8602 Number of Runtime Warnings: 0

      • End of pc-CRACK output***

File No.: 0901350.304 Revision: 3 K

L-2018-174 Attachment 19 Enclosure 1 Page 69 of73 Page A-48 of A-52 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

L-2018-174 Attachment 19 Enclosure 1 Page 70 of 73 A.8 RHR LINE THROUGH-WALL CRACK STRESS INTENSITY CALCULATION pc-CRACK 4.2 CS Version Control No. 4.2.0.0 Structural Integrity Associates, Inc.

www.structint.com pccrack@structint.com Date: 10/03/2018 16:13 Input Data read from C:\\Users\\mfong\\Documents\\Turkey Point LBB\\RHR_TH.pcf Analysis

Title:

Test Problem Units Selected: US Customary Analysis Type: Stress Intensity Factors Crack Model: 311-Through-Wall Circumferential Crack in Cylinder Under Tension And Bending Half Crack Length, a 3.1200 Wall Thickness, t 1.2500 Mean Radius, Rm=

6.3750 Maximum a/(PI*Rm) 0.17 Crack Depth Print Increment for SIF Tabulation 0.01 Total Load Cases: 2 Load Case 1:Max Typ_e: Stress Coefficients Input by User Coefficient CO Coefficient Cl Coefficient C2 Coefficient C3 Load Case 2:Min 17.3800 0.0000 0.0000 0.0000 Type: Stress Coefficients Input by User Coefficient CO Coefficient Cl Coefficient C2 Coefficient C3 messages/Warnings:

-7.6200 0.0000 0.0000 0.0000 Number of Warnings in Inputs: 0 ANALYSIS RESULTS -

STRESS INTENSITY FACTORS Load Case # 1: Max a

a/ (PI*Rm) 3.1200 0.1558 3.1300 0.1563 3.1400 0.1568 3.1500 0.1573 3.1600 0.1578 3.1700 0.1583 File No.: 0901350.304 Revision: 3 68.8554 69.0496 69.2441 69.4388 69.6338 69.8291 K

Page A-49 of A-52 F0306-01Rl

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

3.1800 0.1588 70.0246 3.1900 0.1593 70.2203 3.2000 0.1598 70.4164 3.2100 0.1603 70.6127 3.2200 0.1608 70.8092 3.2300 0.1613

71. 0060 3.2400 0.1618 71.2031 3.2500 0.1623
71. 4005 3.2600 0.1628
71. 5981 3.2700 0.1633 71.7960 3.2800 0.1638
71. 9941 3.2900 0.1643 72.1926 3.3000 0.1648
72. 3913 3.3100 0.1653 72.5902 3.3200 0.1658 72.7895 3.3300 0.1663 72.9890 3.3400 0.1668 73.1887 3.3500 0.1673 73.3888 3.3600 0.1678 73.5891 3.3700 0.1683 73.7897 3.3800 0.1688 73.9906 3.3900 0.1693 74.1917 3.4000 0.1698 74.3931 Load Case # 2: Min a

a/ (PI*Rm) 3.1200 0.1558

-30.1886 3.1300 0.1563

-30.2738 3.1400 0.1568

-30.3590 3.1500 0.1573

-30.4444 3.1600 0.1578

-30.5299 3.1700 0.1583

-30.6155 3.1800 0.1588

-30.7012 3.1900 0.1593

-30.7871 3.2000 0.1598

-30.8730 3.2100 0.1603

-30.9591 3.2200 0.1608

-31.0452 3.2300 0.1613

-31.1315 3.2400 0.1618

-31.2179 3.2500 0.1623

-31. 3045 3.2600 0.1628

-31.3911 3.2700 0.1633

-31. 4779 3.2800 0.1638

-31. 5648 3.2900 0.1643

-31.6517 3.3000 0.1648

-31. 7389 3.3100 0.1653

-31. 8261 3.3200 0.1658

-31.9134 3.3300 0.1663

-32.0009 3.3400 0.1668

-32.0885 3.3500 0.1673

-32.1762 3.3600 0.1678

-32.2640 3.3700 0.1683

-32.3520 3.3800 0.1688

-32.4401 3.3900 0.1693

-32.5282 3.4000 0.1698

-32.6166 Number of Runtime Warnings: 0

      • End of pc-CRACK output ***

File No.: 0901350.304 Revision: 3 K

L-2018-174 Attachment 19 Enclosure 1 Page 71 of 73 Page A-50 of A-52 F0306-01Rl

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

L-2018-174 Attachment 19 Enclosure 1 Page 72 of73 A.9 SURGE LINE THROUGH-WALL CRACK STRESS INTENSITY CALCULATION pc-CRACK 4.2 CS Version Control No. 4.2.0.0 Structural Integrity Associates, Inc.

www.structint.com pccrack@structint.com Date: 10/03/2018 16:14 Input Data read from C:\\Users\\mfong\\Documents\\Turkey Point LBB\\Surge_TH.pcf Analysis

Title:

Test Problem Units Selected: US Customary Analysis Type: Stress Intensity Factors Crack Model: 311-Through-Wall Circumferential Crack in Cylinder Under Tension And Bending Half Crack Length, a 3.3000 Wall Thickness, t 1.1250 Mean Radius, Rm=

5.8125 Maximum a/(PI*Rm) 0.19 Crack Depth Print Increment for SIF Tabulation 0.01 Total Load Cases: 2 Load Case 1:Max Type: Stress Coefficients Input by User Coefficient CO Coefficient Cl Coefficient C2 Coefficient C3 Load Case 2:Min 24.7300 0.0000 0.0000 0.0000 Type: Stress Coefficients Input by User Coefficient CO Coefficient Cl Coefficient C2 Coefficient C3 messages/Warnings:

-0.0900 0.0000 0.0000 0.0000 Number of Warnings in Inputs: 0 ANALYSIS RESULTS -

STRESS INTENSITY FACTORS Load Case # 1: Max a

a/ (PI*Rm) 3.3000 0.1807 3.3100 0.1813 3.3200 0.1818 3.3300 0.1824 3.3400 0.1829 3.3500 0.1835 File No.: 0901350.304 Revision: 3 K

107.3469 107.6578 107.9692 108.2811 108.5935 108.9063 Page A-51 of A-52 F0306-0IRI

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 e

Structural Integrity Associates, Inc.

3.3600 0.1840 109.2197 3.3700 0.1846 109.5335 3.3800 0.1851 109.8478 3.3900 0.1856 110.1626 3.4000 0.1862 110.4779 3.4100 0.1867 110.7937 3.4200 0.1873 111.1100 3.4300 0.1878 111. 4268 3.4400 0.1884 111.7441 3.4500 0.1889 112. 0620 3.4600 0.1895 112.3803 Load Case # 2: Min a

a/(PI*Rm) 3.3000 0.1807

-0.3907 3.3100 0.1813

-0.3918 3.3200 0.1818

-0.3929 3.3300 0.1824

-0.3941 3.3400 0.1829

-0.3952 3.3500 0.1835

-0.3963 3.3600 0.1840

-0.3975 3.3700 0.1846

-0.3986 3.3800 0.1851

-0.3998 3.3900 0.1856

-0.4009 3.4000 0.1862

-0.4021 3.4100 0.1867

-0.4032 3.4200 0.1873

-0.4044 3.4300 0.1878

-0.4055 3.4400 0.1884

-0.4067 3.4500 0.1889

-0.4078 3.4600 0.1895

-0.4090 Number of Runtime Warnings: 0

      • End of pc-CRACK output***

File No.: 0901350.304 Revision: 3 K

L-2018-174 Attachment 19 Enclosure 1 Page 73 of73 Page A-52 of A-52 F0306-01Rl