L-2023-062, Cycle 33 Core Operating Limits Report

From kanterella
Jump to navigation Jump to search
Cycle 33 Core Operating Limits Report
ML23118A092
Person / Time
Site: Turkey Point 
Issue date: 04/27/2023
From: Strand D
Florida Power & Light Co
To:
Office of Nuclear Reactor Regulation, Document Control Desk
References
L-2023-062
Download: ML23118A092 (1)


Text

April 27, 2023 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-00001 Re:

Turkey Point Nuclear Plant, Unit 3 Docket 50- 250 Cycle 33 Core Operating Limits Report L-2023-062 Pursuant to Turkey Point Unit 3 Technical Specification (TS) 6.9.1.7, Florida Power & Light Company (FPL) is submitting the Core Operating Limits Report (COLR) for operating cycle 33.

Should you have any questions regarding this submission, please contact Mr. Kenneth Mack, Fleet Licensing Manager, at 561-904-3635.

Sincerely, 12L-- 5)2--

Dianne Strand General Manager Regulatory Affairs Florida Power & Light Company

Enclosure:

Turkey Point Unit 3, Cycle 33 Core Operating Limits Report cc:

USNRC Regional Administrator, Region II USNRC Project Manager, Turkey Point Nuclear Plant USNRC Resident Inspector, Turkey Point Nuclear Plant Florida Power & Light Company 9760 SW 344th Street, Homestead, FL 33035

Enclosure:

Turkey Point Unit 3, Cycle 33 Core Operating Limits Report (9 pages follow)

14A-A2

1.0 INTRODUCTION

This Core Operating Limits Report for Turkey Point Unit 3 Cycle 33 has been prepared in accordance with the requirements of Technical Specification 6.9.1.7.

The Technical Specifications (TS) affected by this report are listed below with the section and page for each one of the TS addressed in this COLR document.

Section Technical Specification Page 2.1 2.1.1 Reactor Core Safety Limits 14A-A3 2.2 2.2.1 Reactor Trip System Instrumentation Setpoints 14A-A3-14A-A4 2.3 3.1.1.1 Shutdown Margin Limit for MODES 1, 2, 3, 4 14A-A4 2.4 3.1.1.2 Shutdown Margin Limit for MODE 5 14A-A4 2.5 3.1.1.3 Moderator Temperature Coefficient 14A-A5 2.6 4.1.1.3 MTC Surveillance at 300 ppm 14A-A5 2.7 3.1.3.2 Analog Rod Position Indication System 14A-A5 2.8 3.1.3.6 Control Rod Insertion Limits 14A-A5 2.9 3.2.1 Axial Flux Difference 14A-A5 2.10 3.2.2 Heat Flux Hot Channel Factor FQ(Z) 14A-A6 2.11 3.2.3 Nuclear Enthalpy Rise Hot Channel Factor 14A-A6 2.12 3.2.5 DNB Parameters 14A-A6 Figure Description A1 Reactor Core Safety Limit - Three Loops in Operation 14A-A7 A2 Required Shutdown Margin vs Reactor Coolant Boron Concentration 14A-A8 A3 Turkey Point Unit 3 Cycle 33 Rod Insertion Limits vs Thermal Power 14A-A9 A4 Axial Flux Difference as a Function of Rated Thermal Power 14A-A10

14A-A3 2.0 OPERATING LIMITS The cycle-specific parameter limits for the specifications listed in the Introduction are presented below and listed sequentially by Technical Specification (TS). These limits have been developed using the NRC-approved methodologies specified in TS 6.9.1.7.

2.1 Reactor Core Safety Limits - Three Loops in Operation (TS 2.1.1)

Figure A1(page 14A-A7)

In Modes 1 and 2, the combination of Thermal Power, reactor coolant system highest loop average temperature and pressurizer pressure shall not exceed the limits in Figure A1.

2.2 Reactor Trip System Instrumentation Setpoints (TS 2.2.1)

NOTE 1 on TS Table 2.2-1 Overtemperature T 1 = 0s, 2 = 0s Lead/Lag compensator on measured T 3 = 2s Lag compensator on measured T K1 = 1.31 K2 = 0.023/F 4 = 25s, 5 = 3s Time constants utilized in the lead-lag compensator for Tavg 6 = 2s Lag compensator on measured Tavg T 583.0 F Indicated Loop Tavg at RATED THERMAL POWER K3 = 0.00116/psi P 2235 psig Nominal RCS operating pressure f1(I) = 0 for qt - qb between - 18% and + 7%.

For each percent that the magnitude of qt - qb exceeds - 18%,

the T Trip Setpoint shall be automatically reduced by 3.51%

of its value at RATED THERMAL POWER; and For each percent that the magnitude of qt - qb exceeds +7%,

the T Trip Setpoint shall be automatically reduced by 2.37%

of its value at RATED THERMAL POWER.

Where qt and qb are percent RATED THERMAL POWER in the top and bottom halves of the core respectively, and qt + qb is total THERMAL POWER in percent of RATED THERMAL POWER.

14A-A4 NOTE 2 on TS Table 2.2-1 Overtemperature T The Overtemperature T function Allowable Value shall not exceed the nominal trip setpoint by more than 0.5% T span for the T channel, 0.2% T span for the Pressurizer Pressure channel, and 0.4% Tspan for the f(I) channel. No separate Allowable Value is provided for Tavg because this function is part of the T value.

NOTE 3 on TS Table 2.2-1 Overpower T K4 = 1.09 K5 0.0/F For increasing average temperature K5 = 0.0/F For decreasing average temperature 7 0 s Time constants utilized in the lead-lag compensator for Tavg K6 = 0.0016/F For T > T K6 = 0.0 For T T T 583.0F Indicated Loop Tavg at RATED THERMAL POWER f2 (I) = 0 For all I NOTE 4 on TS Table 2.2-1 Overpower T The Overpower T function Allowable Value shall not exceed the nominal trip setpoint by more than 0.5% T span for the T channel. No separate Allowable Value is provided for Tavg because this function is part of the T value.

2.3 Shutdown Margin Limit for MODES 1, 2, 3 and 4 (TS 3.1.1.1)

Figure A2 (page 14A-A8) 2.4 Shutdown Margin Limit for MODE 5 (TS 3.1.1.2)

> 1.77 % k/k

14A-A5 2.5 Moderator temperature coefficient (MTC) (TS 3.1.1.3)

< + 5.0 x 10-5 k/k/F BOL, HZP, ARO and, from HZP to 70% Rated Thermal Power (RTP)

From 70% RTP to 100% RTP the MTC decreasing linearly from < + 5.0 x 10-5 k/k/F to < 0.0 x 10-5 k/k/F Less negative than - 41.0 x 10-5 k/k/F EOL, RTP, ARO 2.6 Moderator temperature coefficient (MTC) Surveillance at 300 ppm (TS 4.1.1.3)

Less negative than - 35.0 x 10-5 k/k/F (-35 pcm/°F)

Within 7 EFPD of reaching equilibrium boron concentration of 300 ppm.

The Revised Predicted near-EOL 300 ppm MTC shall be calculated using the algorithm contained in WCAP-13749-P-A:

Revised Predicted MTC = Predicted MTC + AFD Correction - 3 pcm/°F If the Revised Predicted MTC is less negative than the SR 4.1.1.3.b 300 ppm surveillance limit and all the benchmark criteria contained in the surveillance procedure are met, then an MTC measurement in accordance with SR 4.1.1.3.b is not required to be performed.

The neutronics methods used with WCAP-13749-P-A are those described in WCAP-16045-P-A, Qualification of the Two-Dimensional Transport Code PARAGON, August 2004.

2.7 Analog Rod Position Indication System (TS 3.1.3.2)

Figure A3 (page 14A-A9)

The All Rods Out (ARO) position for all shutdown Banks and Control Banks is defined to be 229 steps withdrawn.

2.8 Control Rod Insertion Limits (TS 3.1.3.6)

Figure A3 (page 14A-A9)

The control rod banks shall be limited in physical insertion as specified in Figure A3 for ARO = 229 steps withdrawn.

2.9 Axial Flux Difference (TS 3.2.1)

Figure A4 (page 14A-A10)

14A-A6 2.10 Heat Flux Hot Channel Factor FQ(Z) (TS 3.2.2)

[FQ]L = 2.40 K(z) = 1.0 For 0 < z < 12 where z is core height in ft 2.11 Nuclear Enthalpy Rise Hot Channel Factor (TS 3.2.3)

FHRTP = 1.650 PFH = 0.3 2.12 DNB Parameters (TS 3.2.5)

RCS Tavg < 585.0 oF Pressurizer Pressure > 2204 psig

14A-A7 Ill QI

.J::.

.,2l

i::

Figure A1 Reactor Core Safety Limit - Three Loops in Operation 680 ~----~----~---~---------~----~----~

2455 psia Unacceptable Operation Acceptable Operation 560 +-----+----------j------+----------+------+----+---------,

540 +-----+------f--------+----~------+--------+--------4 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 Core Power (fraction of 2644 MWt)

14A-A8 2

10.0, 1.77) 1.S

~ } -z

<.!)

~

~

z 1

~

0 g

~

)
c

~

0 LU a::: -s o.s a::

0 0

Figure A2 Required Shutdown Margin vs Reactor Coolant Boron Concentration 500 1000 1500 RCS BORON CONCENTRATION (PPM) 2000

14A-A9 FIGURE A3 Turkey Point Unit 3 Cycle 33 Rod Insertion Limits vs Thermal Power ARO = 229 Steps Withdrawn, Overlap = 101 Steps 230 220 210 200 190 180 170 160 I 150

-a 140 i

130 I

120 110 C

100 90 i

80

~

70 eo 50 40 30 20 10

.V 64, 229 V"

V 55.2, 212 V

V

~/

100,1 71

... v

/

~,,,,-

V

.J V V

BankC

~V

.v

... /

-' 0, 105

~V

... v

~,,,,-

.J V'" BankD

~

~

~.,

,,,, i,.,-

/,

/

I,,""

12, 0 /,

0 0

10 20 30 40 50 eo 70 80 90 100 Percent Reactor Power

14A-A10 FIGURE A4 Axial Flux Difference as a Function of Rated Thermal Power Turkey Point Unit 3 Cycle 33 120 100 l

a: i 80 I

I eo C

~

I 40 J

20 0

-50 V

UNAC t:EPTABLE /

OPE RATION V

(-30,50)

-40

-30

-20

(-9,100)

(+7,100)

\

/

\ \

ur UACCEPTAI BLE OPERATIOI-J

\

ACCEPTJ ~LE OPERAT ON

(+20,50)

-10 0

10 20 30 40 Axlal Flux Dlffarance ('!t)