IR 05000266/1985014

From kanterella
Revision as of 00:05, 3 July 2020 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Special Physical Security Insp Repts 50-266/85-14 & 50-301/85-14 on 850712-17 in Region III Ofc & 850715-16 Onsite.Violation Noted:Unauthorized Firing of Weapon.Details Withheld (Ref 10CFR73.21(c)(2))
ML20134C332
Person / Time
Site: Point Beach  NextEra Energy icon.png
Issue date: 08/12/1985
From: Creed J, Pirtle G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML20134C252 List:
References
50-266-85-14, 50-301-85-14, NUDOCS 8508160274
Download: ML20134C332 (1)


Text

-

o' .

)

U. S. NUCLEAR REGULATORY COMMISSION

REGION III

Reports No. 50-266/85014(DRSS); 50-301/85014(DRSS)

' Docket Nos. 50-266; 50-301 Licenses No. DPR-24; DPR-27 Safeguards Group IV Licensee: Wisconsin Electric Power Company 231 West Michigen Milwaukee, WI 53201 Facility Name: Point Beach Nuclear Plant, Units 1 and 2 Inspection At: Point Beach Site, Two Rivers, WI Inspection Conducted: July 12 and 17, 1985 in Region III Office July 15-16, 1985 onsite Date'of Previous Physical Security Inspection: January 21-25, 1985 Type of Inspec tion: Announced Special Physical Security Inspection Inspector: /d 8I

'

GL. Pirt 1e Date'

P,1ysical Security Inspector Approved By: k 8!/2[8f

.() R. Creed, Chief Date Safeguards Section Inspection Summary Inspection on' July 12-17, 1985 (Reports No. 50-266/85014(DRSS);

50-301/85014(DRSS))

Areas Inspected: Included a review of the circumstances pertaining to a weapon fired on July 12, 1985 and the licensee's action pertaining to the incident. A review of the licensee's weapon safety / control program was also conducted. The inspection involved 15 inspector-hours by one NRC inspector. The inspection began during the day shif Results: One violation was noted during the inspection. The violation met the criteria in 10 CFR Part, Appendix C,Section IV.A as a licensee idcntified item. Therefore, a Notice of Violation was not issue Security Organization: A weapon was fired under circurastances not authorized by the licensee's Security Pla The licensee's investigation of the weapon firing incident was considered adequate. Corrective actions to prevent recurrence of the incident also appeared adequate. No significant personal injury and no equipment damage resulted from the weapon firing inciden (DETAILS: UNCLASSIFIED ) Enclosure contains SAFEGUARDS INFOTCIATION 5081go fMBPDR- Upon separation this G Page is Decontrolled Nw r 'N