ML19309F126

From kanterella
Revision as of 10:22, 1 February 2020 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Forwards Interim Deficiency Rept Re Damaged Instrumentation Cables Under Reactor Pressure Vessel
ML19309F126
Person / Time
Site: Grand Gulf  Entergy icon.png
Issue date: 03/31/1980
From: Dale L
MISSISSIPPI POWER & LIGHT CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19309F127 List:
References
AECM-80-60, NUDOCS 8004280517
Download: ML19309F126 (1)


Text

'

C

~

.iy

cn - - - -

MISSISSIPPl POWER & LIGHT COMPANY Helping Build Mississippi P. O . B OX 164 0. J A C K S O N. MIS SIS SlP PI 3 9 2 0 5

/'  :: 31

= =ooveriou o caa =Tu c u r March 31, 1980 Office of Inspection & Enforcement U. S. Nuclear Regulatory Commission Region II 101 Marietta St., N.W., Suite 3100 Atlanta, Georgia 30303 Attention: Mr. J. P. O'Reilly, Director

Dear Mr. O'Reilly:

SUBJECT:

Grand Gulf Nuclear Station Units 1 and 2 Dockets Nos. 50-416 and 50-417 File 0272/15526/L-860.0 PRD-80/03, Interim Report, Damaged Instrumentation Cables Under Reactor Pressure Vessel AECM-80/60 On February 28, 1980, Mississippi Power & Light Company notified Mr. M. J. Gouge of your office of a deficiency concerning damaged instru-mentation cables under the Reactor Pressure Vessel (RPV). Mr. Gouge was notified at that time of our determination that this matter was not re-portable within the meaning of 10CFR50.55(e). This notification was made for information purposes only. On March 6, 1980, Mr. Gouge informed Mississippi Power & Light Company that this deficiency should be considered and processed as a reportable condition.

tur interim report on this deficiency is attached. Our investigation and corrective action plan is presently incomplete. We expect to provide a final report on this matter by June 9, 1980.

Yours truly, I Fge gy L. F. Dale Nuclear Project Manager JGC/JDR:ts l Attachment I l

cc: Mr. N. L. Stampley 30/f i

1 Mr. R. B. McGehee $C j Mr. Victor Stello, Jr., Director //

Division of Inspection and Enforcement l U. S. Nuclear Regulatory Co= mission i 20555 Washington, D. C.

Member Middle South Utilities System 8004280 7