Port Gibson, MS 39150 Tel 601437 2800 September 8,1999 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555
Subject:
Grand Gulf Nuclear Station Unit 1 Docket No. 50-416 License No. NPF-29 FHA Operational Conditions Proposed Amendment to the Operating License, LDC 1999-051
References:
- 1) GNRO 99/00049, FHA Operational Conditions Proposed Amendment to the Operating License, LDC 1999-051, dated June 23,1999
- 2) GNRO 99/00063, Information Supporting the Review of Reference 1, dated August 6,1999 GNRO-99/00070 Gentlemen:
Reference 1 requested technical specification changes to relax selected operational constraints during an outage. In response to questions from the NRC, Reference 2 transmitted supplemental information. This information included, in item 1, calculated dose results for both offsite and control room locations. In particular, the control room skin dose results were reported to be 0.088 and 0.127 rem for the two evaluated cases.
GGNS has discovered the dose calculation utilized a non-conservative geometry factor for this parameter. The above results are being revised to 1.5 and 2.2 rem, respectively. The skin dose is still not limiting in either case and is well below the regulatory limit of 30 rem in both cases.
The calculation error is being evaluated in accordance with our corrective action program. It is hoped that verbal communication of this issue on August 31,1999 and this letter will help to minimize any impact on your review and approval of our request. If you have any questions regarding the requested change, please contact Jerry Burford (601) 437-2714.
Yours truly, b
i 14o060 g
1 C. A. Bottemiller h
Manager, Plant Licensing l
/FGB/be cc:
(See Next Page) 9909150079 990908 PDR ADOCK 05000416 p
-,+ p,,
4 GNRO-99/00070 Page 2 of 2 cc:
Ms. J. L. Dixon-Herrity, GGNS Senior Resident (w/a)
Mr. D. E. Levanway (Wise Carter)
Mr. L. J. Smith (Wise Carter)(w/a)
Mr. N. S. Reynolds (w/a)
Mr. H. L. Thomas (w/o)
Mr. E. W. Merschoff (w/a)
Regional Administrator U.S. Nuclear Regulatory Commission -
Region IV 611 Ryan Plaza Drive, Suite 400 Arlington,TX 76011 Mr. S. P. Sekerak, NRR/DLPM/PD IV-l (W/2)
U.S. Nuclear Regulatory Commission One White Flint North, Mail Stop 04-D3 11555 Rockville Pike Rockville, MD 20852-2378 I
J