s Page 1 of 26 I

o EVALUATION RESEARCH CORPORATION UNCONTROLLED COPY.

COMANCHE PEAK RESPONSE TEAM QUALITY INSTRUCTION FOR ISSUE-SPECIFIC ACTION PLAN VII.C 1

i j

l INSTRUCTION NO.: QI-051 REVISION: 3 ISSUE DATE: 03-27-87 e.

g REINSPECTION OF PIPE WHIP RESTRAINTS

'3///[f7 Prepared by:

Date:

/-

Approved by:

M Date: 3 - $2 f"f '7 Iss e Coordinator Approved by:

Datt: 8-Mb ~O On-SiteQARegsentative Approved by:

b Date:

S h7

/~

Q(//CReviewTeamLeader

/

B708120133 B70731 PDR ADOCK 0500 5

2

0I-051 REV. 3 4

1.0 ' PURPOSE-

p/ ~

3 This-instruction provides' direction and accept / reject criteria fore

~,,

.the visual reinspection of Pipe Whip Restraints and Support p

Structures.

'2.0 APPLICABILITY This instruction applies the requirements of Action Plan VII.c to safety related Pipe Whip Restraints and Support Structures which have been final QC accepted.

3.0 REFERENCES

3.1. Memo (QA/QC-RT-464) to A. Patterson from R. H. Brown

. delineating documentation used in' development of this

' instruction.

3.2 CPP-009, " Performance of Reinspection and Documentation Reviews."

4.0 GENERAL

~

4.1 Responsibilities j-t^

4.1.1 QA/QC Discipline Engineers

.The QA/QC Discipline Engineers prepare the quality instruction delineating reinspection requirements and attributes.

4.1.? QA/QC Inspectors The QA/QC Inspectors perform reinspection in accordance with this inspection instruction and established project procedures. Reference 3.2 addresses the method to perform reinspection and to document and process the results.

4.2 Policy Activities performed.under this instruction shall conform to the~ policies contained in the latest Comanche Peak Response

. Team Program plan and Issue Specific Action Plan VII.c.

2 1

l..,

l-l-

-QI-051 REV. 3

's 5.0 INSTRUCTIONS Using the information in Refe'cence 3.2 and this instruction.

perform the reinspection of items in this population and document the results on the checklist (Attachment 6.1).

[See Notes 1, 4, 5, and 7) l 5.1 Identification [(1); See Note 2]

l j

Verify that the Restraint or the Support Structure is permanently marked with the proper identification number as I

indicated below.

Except for U-Bar restraints, if the permanent marking is not visible due to paint, mark the.

j attribute "N/A" on the checklist and note " inaccessible".n the remarks column.

U-Bar Restraint is identified by the Restraint no. on the metal tag permanently attached to the U-Bar.

Bumper Restraint is. identified by the assembly identification no. shown on the vendor dwg. in Unit 1 and by the Restraint number in Unit 2.

Hard Restraint is identified by the structural detail,'

no. on Gibbs and Hill structural drawings.

for Honeycomb Restraint, the Honeycomb is identified by g

the mark no. on Gibbs & Hill structural drawing and the Structure is identified by the vendor drawing piece numbers.

Moment Restraints are identified by the Restraint no.

on the forging.

Restraints supplied by Westinghouse are identified by the equipment number shown on Westinghouse drawing or by piece number on the vendor drawings.

Support Structure is identiiled by the vendor drawing piece numbers.

Identification is necessary of as many pieces as makes the Inspector comfortable that he/she is at the correct support structure.

5.2 Location (2)

Verify, by measurement, the location of the Restraint / Support structure as indicated below.

O 3

J

QI-051 REV. 3 5.0 INSTRUCTIONS (Cont'd)

! ;(,-)

5.2 Location (Cont'd)

Location of a Support Structure is verified if, with respect to the Structure, the. location of all the corresponding Restraints on the Structure is per the drawing. The elevation / location of the Support Structure itself is for reference only.

If no Restraint is installed, the Inspector shall "N/A" this attribute on the Checklist.

If Restraint location is not shown on the drawing, the Engineer shall either "N/A" this attribute or provide Supplemental Instructions for this verification.

Unless shown otherwise on the drawing, the following tolerances apply for location of the. Restraints on the Support Structure:

U-Bar Restraint:

1 2" Bumper Restraint:

! 1/8" Moment Restraint:

t 1/2"

, -~g Honeycomb Restraint:

1/4" Hard Restraint:

2 1/4" Location of all Restraints, except Moment Restraints, is verified if, the Restraint location with respect to the pipe elbow is per the drawing. Moment Restraint location needs no verification. Note that location for a U Bar Restraint may be specified as dimension

'3' on the HFT (Hot Functional Testing) Card included in the package.

Unless shown otherwise on the drawing, the following tolerances apply:

U-Bar Restraint:

1 1/8" Bumper Restraint:

1 1/8" Hard Restraint:

1/4" Honeycomb Restraint:

1 1/4" 5.3 Orientation (3)

Verify that the Restraint / Support Structure orientation is as b(%

shown on the applicable drawings.

4

l 01-051 1

REV. 3.

5.0 INSTRUCTIONS (Cont'd)

()

(,,/

5.4 Configuration (4) 5.4.1 Components (4A)

Verify visually that components of the hardware match the drawing and that the assembly is per the drawing.

(See Note 3) 5.4.2 Materials (4B) (See Note 7)-

1)

For high strength structural bolting and high strength thru anchor bolts, verify that the hardware matches the drawing. Paint shall be removed, if necessary, for this verification.

ASTM A325 may be substituted with ASTM A449.

11)

For U-bar Restraints, verify that the U-bolt size is per the drawing.

iii) For all other components of the Restraint /

Support Structure, record on Attachment 6.2 thoseheat,numbersorpartnumbersthatarej' legible on the component.

For components assembled in shop, only the assembly

[,_

identification or identification of a unique component in the assembly need be recorded.

Paint need not be removed.

5.4.3 Installation (4C) i)

Level and Plumb: Verify by measurement that the Restraint / Support Structure is level and plumb within the tolerances indicated below.

Support Structure, Hard Restraint. Honeycomb Restraint: 1 1/8" per foot with maximum deviation not to exceed 1/2" over total piece dimension.

Moment Restraints:

i 1/4" per foot with maximum deviation not to exceed I" over total piece dimension. Level and plumbness in this case refer to the base plate and capture plate respectively. (See Attachment 6.7)

Unless specified on the drawing, there are no level and plumbness requirements for other Restraints.

5

OI-051 REV. 3 5.0 INSTRUCTIONS (Cont'd) i ("

+

5.4 Configuration (Cont'd)

\\s_

5.4.3 Installation (Cont'd) 11)

Dimensions: Verify by measurement, that,the dimensions required to be maintained in the field are within the tolerances given on'the drawing.

Listed below are some generic tolerances:

Spacing between Bumpers in a multi Bumper installation: 1 1/8" On 'c' dimension shown on Bumper Restraint drawings:

2 1/8" On Support Structures: 11/16" for dimensions d(30' 1 1/8" for dimensions )>30' 111) Restraint Specific: Verify that the following Restraint specific requirements are met:

(O)

Bumper Restraints:

Verify visually that the mating surfaces for which drawing calls out the requirement " Bear", are in contact at edges.

U-Bar Restraints: Verify visually that the bearing plate covers the entire bent portion of the U-bolts. Also verify that the threaded portion of the U-bolt is completely engaged in the clevis.

Cotter Keys: Where Cotter Keys are required by t;ie drawing, verify visually that the ends were sufficiently deformed after insertion to prevent withdrawal.

5.4.4 Base plates (4D) (See Note 6)

Where drawing requires grout, verify visually that grout exists and that mating surfaces are flush. When mating surfaces are not flush, verify, using feeler gages if the following acceptance criteria is met:

~~

\\s_/

6

_____--__ ___--_--_-_--__ _ - - A

OI-051 REV. 3 5.0 INSTRUCTIONS (Cont'd)

' /"N 5.4 Configuration (Cont'd) 3 5.4.5 Shimming (Cont'd) j l

Inside Containment: Gaps between the. base plate ^and the concrete shall be less than 1/16 inch for_ at least 80% of the base plate area..It may exceed 1/16 inch for a maximum of 20% of plate but shall not be more than 1/2 inch at any point. Acceptance may be established based on percentages of perimeter, rather than area.

{

i Outside Containment: Acceptance criteria is j

same as for inside Containment except that the maximum permissible gap is 1 inch instead

-of 1/2 inch.

5.4.5 Shimming (4E)

Verify that shimming is per the drawing requirements and the following generic requirements are met:

U-Bar Restraints: Verify that there is'no visible shim between the Restraint bracket and the Support Structure.

Support Structures:

a.

Verify visually that shims cover 100% of the mated parts, b.

For bearing connections, verify by measurement that the total thickness of loose (unwelded) shims does not exceed 1/4 inch and that the remaining gap is filled by a single shim welded all around to one of the interfaced plates with a fillet veld. The requirements of Section 5.8 do not apply to these welds.

Moment Restraints:

a.

Verify that the requirements of a and b for Support Structures above are met.

b.

Verify visually that shims between capture plate and forging, bear fully against the capture plates.

)

7

QI-051 REV. 3

.5.0' INSTRUCTIONS-(Cont'd)

~

(

\\1 s /l 5.4.6 Attachments (Cont'd) s Bumper Restraints:

For shims between Bumper Restraints and Support Structures:

/

a.

Verify that the shim thickness is not less than 1/4 inch, b.

Verify that the. shim is either one piece or meets the requirements of.16.

5.4.6 Attachments (4F)

Verify that the instrument bracket attachments to Restraints and Support Structures meet the following requirements:

There shall be a clear ' distance of 1" +

diameter of standard washer or 4" +

dimensions of plate washer at bolts.

1" clear distance from weld edges.

tO 1" clear distance from any edge of Bumper or-U-bar attachments.

5.5 Gaps (5) 5.5.1 Environment (SA)

Record Ambient Temperature and the System Conditions.

(i.e., pipe empty, filled with water, operating at F,__ psi). This data will be obtained from TUGC0 Operations / Maintenance.

5.5.2 Cap (SB)

Verify by measurement that the gap between the bare pipe and the Restraint is within the tolerances specified on the drawing.

If the System is under testing and has a temperature of above 120*F (based on information obtained in 5.5.1 above), record the temperature and the gaps on a Supplemental Information.

Sheet and enter "N/A" on the checklist for this attribute. The discipline engineer will evaluate the gaps for acceptance and issue deviation reports, if appropriate. Listed below are some generic tolerances:

O 8

i

QI-051 i

REV. 3 5.0 INSTRUCTIONS (Cont'd)'

Q' 5.5 Gaps (Cont'd)

U-Bar Restraints: Gaps on U-Bar Restraints are shown as dimension "1" and "2" on HFT (Hot Functional Testing) data cards or i

dimensions D and 6 on G6H App. 7 to MS-94 drawings. Use the following tolerances on i

these gap dimensions unless otherwise l

indicated on the drawing:

j Dimension "1" or Dimension D:

1 1/16" Dimension "2" or Dimension A :

1 1/2" '

Bumper Restraints: Tolerance on "g"

dimension:

(+ 1/16", - 1/8")

Moment Restraints: Unless shown otherwise on i

the drawing the following tolerances apply:

{

a.

Where design shows 1/16" on both sides, the. total dimensional t'olerance shall be 1/8" ! 1/16" (e.g. 0" on one side with 1/8" t 1/16" on the other, 1/16" ! 1/32" on

{

both sides or any combination) b.

Where design shows 0" on one side and 1/16" on the other side the sum of both gaps may not exceed 1/8" or be less than 1/32".

c.

Where the design shows clearances greater than 1/4", the dimension shown is the minimum.

5.6 Bolted Joints (6) i 5.6.1 Size and Number (6A)

Verify that the number of bolts and the bolt size is per the drawing.

Except for Moment Restraints, the required bolt size is 7/8 inch if not shown on the drawing.

5.6.2 Joint Details (6B)

Record joint details on Attachment 6.6.

If the drawing does not call for high strength bolts, it is not necessary to remove paint.

In such cases if the bolt O

head has no visible markings indicate so on Attachment 6.6.

9 1

.-__-___-_-____a

J.

QI-051 REV. 3 5.0 INSTRUCTIONS (Cont'd).

- 'O l Q-5.6 Bolted Joints (Cont'd) 1 l

5.6.3 Washer (6C)

Verify visually that a washer is installed and that it completely covers the hole.

5.6.4 ' Slope (6D)

Verify by measurement that the slope of bolted parts in contact with the bolt head and nut does not exceed 1:20 with respect to a pit.ne normal to the bolt axis. Where the slope is greater, verify visually that a beveled washer has been installed to provide full bearing to the head or nut.

5.6.5 Torque (6E) (See Note 8)

Verification of joint tightness using a wrench as required herein, will be performed only-when the joint is unpainted.

For bearin'g type connections, verify that th'e' bolt or nut cannot be rotated by hand.

Except for Moment Restraints, all connections

,O are-bearing type unless noted otherwise on V-the drawing.

5.6.5 Torque.(Cont'd)

For friction type connections, verify using a calibrated wrench that the bolts are torqued to the value specified in 70%, torque column of Attachment 6.14.

Record the wrench number and date of calibration on the Checklist.

]

For hand tight connections, verify that the bolt or nut cannot be rotated by hand (in the tightening direction).

For bolted connections where a specific torque is called out on the drawing, verify the torque using a calibrated wrench.

The value of torque used for this verification will be 70% of tie minimum torque specified.

Record the wrench number and date of calibration on the Checklist.

t 10

QI-051 REV. 3 5.0 INSTRUCTIONS (Cont'd)

D

. Q(.

5.6 Bolted Joints (Cont'd)

Except for hand tight connections, verify that the mating parts are solidly seated j

together such that there are no visible gaps unless shown otherwise.on the drawing..If a deviation exists, indicate maximum gap (between any two mating Surfaces) in the Connection on the Deviation Report.

5.6.6 Locking Device (6F) (See Note 8)

For bearing type connections utilizing high

' strength bolts of nominal diameter 1 inch and larger, verify visually that there is a jam l

nut or the threads have been spoiled to prevent the nuts from loosening.

For b'lts through slotted holes and other o

g connections noted as hand tight, verify that the nut is hand tight and that there is a jam nut or the threads have been spoiled to prevent the nut from loosening. Another acceptable locking method is per Attachment 6.5.

V) 5.6.7 Nut Engagement (6G) 1 Verify that nut of each bolt has proper engagement such that the end of the bolt is not lower than the top of the nut, unless shown otherwise on drawing. When standard 3

nuts are used as jam nuts (outer nut), they

-l shall have a minimum thread engagement of one

.]

half the nut depth.

j 5.7 Anchor Bolts (7) 5.7.1 Richmond Inserts and Embedded Bolts (7A) 1)

Size and Number: Verify that the number of bolts and the bolt size is per the drawing.

11)

Spacing for field drilled holes: Verify by measuring to the nearest 1/16 inch, that the bolt spacing is as shown on the drawing.

Unless shown otherwise on the drawing, verify that the minimum edge distance requirements of Attachment 6.4 are met.

l 11

QI-051 REV. 3 5.0 INSTRUCTIONS (Cont'd)

  1. 3

, )

5.7 Anchor Bolts (Cont'd) 5.7.1 Richmond Inserts and Embedded Bolts (Cont'd) iii) Washer: Verify that a washer is installed and that it completely covers the hole, iv)

Slope: Verify by measurement that the slope of surfaces of bolted parts in contact with the bolt head or nut does not exceed 1:20 with respect to a plane normal to the bolt axis. Where the slope is greater, verify that a beveled washer has been installed per.15.

v)

Torque: Verify that the nut or the bolt cannot be rotated by hand.

vi)

Nut Engagement: Verify nut of each embedded bolt has proper engagement such that the end of the anchor bolt is not lower than the top of the nut, unless shown otherwise on drawing.

vii) Thread Engagement for Richmond Inserts k_)

The verification of thread engagement as required in this section will be performed for each Richmond insert (or screw anchor) specifically called out on the drawing.

Where drawing allows either a Richmond or an embedded anchor, the verification of this section will be performed on those anchors which can be identified to be Richmond inserts (i.e., where bolts rather than studs have been used in Richmond inserts).

{

Verify the thread engagement for Richmond inserts is at least 2 times the bolt diameter plus 1/8 inch. Thread engagement shall be

{

calculated as shown below using bolt length

.specified on the design drawing.

Where bolt / stud length is not specified on the design drawing, the length shall be determined by an ultrasonic examination performed by Brown & Root in accordance with Reference QI-QAP-10.2-4B.

This information shall be transmitted to the inspector by Brown & Root in writing. The inspector shall i

include this report in the reinspection j

7-g package and based on this information verify

(

f the thread engagement per the sketches shown below.

12 i

QI-051 REV. 3 5.0 INSTRUCTIONS (Cont'd) 5.7 Anchor Bolts (Cont'd)

I MAffil4L M

k.... n a

wasi,se

/h *l

  • . * ? '.'..

~

h\\ KNNNNN'S g xx x xx xx xx u% %NN v-g>

e

/A. : :,.

a

/

8 4

a A

_I.

M de _

f, C. W

~

L BOLTS IN RICHMOND INSERTS Thread engagement (E) = L - (B + W+ M + G)

Where:

B = thickness of bolt head, in.

i W = thickness of washer stack, in.

M = thickness of material, in. (i.e., baseplate, tube

{

steel, etc.)

Ga thickness of grout, in. (where applicable)

{

L = overall length, in. (if from design dwgs: B-0) l

' O 13

7 QI-051 REY. 3 5.0 INSTRUCTIONS (Cont'd)

\\

5.7 Anchor Bolts (Cs9t'd)

I

-G 400T PAATE AIA L s.

wasur e M.... -*

NUT x g

l Y//// /////////

////

J YH/Hfff

/

'f,,,,',,',:*

A 9.

d b

k o

_T -

N _

M

  • =

3 m

,1, n e

j L

{

z STUDS IN RICHMOND INSERTS Thread engagement (E) = L - (T + N + W + M + G)

Where:

T = extension from top of n'ut, in.

N = thickness of nut, in.

W = thickness of washer stack, in.

M = thickness of material, in. (i.e., baseplates)

G = thickness of grout, in. (where applicable)

L = overall length, in.

O 14

r

~- -

w

-QI-051 REV. 3 5.0 INSTRUCTIONS (Cont'd)

. f)).

(,

5.7 Anchor Bolts (Cont'd) 5.7.2 Concrete Expansion Anchors (Hilti Bolts)(7B):

1)'

Size and no. of anchors:

Verify by measurement to the nearest 1/8 s

inch, anchor bolt diameter.

Larger diameter Hilti-Kwik bolts and Super Kwik bolts may be substituted for the bolt sizes shown on the drawings.

Hilti Super Kwik bolts may be substituted for Hilti Kwik bolts provided they are equal in diameter. This does not apply when 8" minimum embedment is required for a 1" O HKB.

Determine anchor bolt length by the letter designation stamped on the top of the bolt (See Attachment 6.8).

Bolts of 19 inch length and greater may be stamped with a number corresponding to the bolt length in inches instead of the stamped letter designation. Remove paint, if necessary.

('_)

Super kwik bolts are identified by a star in

%s./

addition to the letter designation.

If length identification is not verifiable or visible, an ultrasonic examination shall be performed in accordance with QI-QAP-10.2-4B.

(Brown & Root shall perform UT and provida copy of results to inspector for inclusion in verification package). Once ultrasonic examination is complete, record actual length on inspection checklist in remarks column and report as deviation.

i Verify that type, size and number of anchors match those shown on the drawing.

ii)

Embedment Length:

Verify that the Hilti anchor bolt embedment plus the nut thickness (from Attachment 6.8) for the anchor being measured is not less then the "Embedment length" or " Minimum Embedment Length" identified on the drawings; or lacking such information the " Minimum Embedment" identified on Attachment 6.8.*

O 15

QI-051-REV. 3 l

5.0 ~ INSTRUCTIONS (Cont'd)

,- s

( )-

5.7 Anchor Bolts (Cont'd) 5.7.2 Concrete Expansion Anchors (Cont'd)

Determine the Hilti anchor bolt embedment by measuring the projected length of the anchor bolt from the structural concrete ** surface.

Subtract the anchor projected length from the designated anchor length to arrive at the Hilti anchor bolt embedment. The designated anchor length is that shown on Attachment 6.8, unless the stamp is indistinguishable in which case the U.T. recorded length should be used.

Requirement of minimum embedment for larger -

diameter Hilti Kwik bolts or Super Kwik bolts when substituted for bolts specified on the drawings, is as shown on the drawings or 4 1/2 diameters for Hilti bolts and 6 1/2 diameters for Hilti Super Kwik bolts whichever,is greater, minus the height of oge nut of the size of the Hilti being measured.'

iii) Bolt Spacing Verify for each Hilti, center-to-center spacing of adjacent anchors of the same size (not on the same fixture) is not less than 10 anchor diameters unless specified on drawing.

For unequal sized bolts, the minimum spacing (unless shown on dwg) is as shown on.9.

Verify spacing of each Hilti to existing Richmond Inserts, concrete edges, abandoned holes, Hilti anchors or embedded anchor bolts that have been cut off meet the minimum spacing requirements specified in Attachment 6.10, unless shown otherwise' en the drawing.

When the letter designation stamped on Hilti bolt is not identified by Attachment 6.8 the following Hilti bolt attributes regardinF length of Hilti's can conservatively be inspected by using.13.

In floor and roof areas where topping has been placed, the thickness of the topping shall be taken into account in determining the projected length.

In these areas the thickness of the topping shall be added to the measured projected length taken from the g--

concrete surface.

The inspector shall ensure that a measurement

(

for topping is provided in the inspection package for all floor or j

roof slabs.

This value may be "0" if the floor or roof has been i

monolithically placed.

16

01-051 REV. 3 5.0 INSTRUCTIONS-(Cont'd)

A(,)

'5.7 Anchor Bolts (Cont'd) 5.7.2 Concrete Expansion Anchors (Cont'd)

Verify that the minimum distance o'f each Hilti anchor to any adjacent embedded plate meets the following requirements of.1.'.

a.

Attachments located within 12 inches of a Hilti anchor bolt shall have spacing as shown on Attachment 6.11.

b.

For embedded plates without anyj attachment within 12 inch clearance distance, the anchor may be as close-as practical to the' edge of the plate without damage to the plate.

iv)

Angularity Verify.that each Hilti installed has its longitudinal axis within 6' from the perpendicular of the surface it gets into..12 gives inspection requirements.

v)

Concrete Damage Verify visually.that structural concrete surrounding the fixture is not broken or spalled as a result of installing the Hilti anchor.

If spalling exists, verify the depth does not exceed the following:

Hole Size Maximum Acceptable Spall Depth

  • 5/8" & under 1/2 inch 3/4" to 1-1/4" inclusive 3/4 inch vi)

Nut Engagement and Bearing Verify nut of each Hilti anchor has proper engagement such that the end of the anchor bolt is not lower than the top of nut, unless I

otherwise shown on drawing.

,r s If the area in question has a topping the maximum spall depth may be-increased to the depth of topping.

17

)

a:

QI-051 REV. 3 5.0 INSTRUCTIONS (Cont'd) 1

(,_,/

5.7 Anchor Bolts (Cont'd) 5.7.2 Concrete Expansion Anchors (Cont'd)

Verify that nut and washer of each Hilti i

anchor has proper bearing and that a minimum of one washer (standard or plate) has been provided. The washer shall completely cover

.the hole in the baseplate.

Verify by measurement that the slope of surfaces of bolted parts in contact with the bolt head does not exceed 1:20 with respect to a plane normal to the bolt axis. Where the slope is greater, verify that a beveled washer has been installed per Attachment 6.15.

Verify that no visible weld has been made to the anchor bolt or nut.

Verify nut for each anchor has not bottomed out. Use thread length in Attachment 6.8 (or Attachment. 6.13 if not available) and measured projection to determine acceptance. '

f-3 5.8 Welding (8)

Prior to start of inspection assure that welds are clean and free of any foreign material that may preclude an adequate visual inspection. Coatings need not be removed.

If, however, the inspector feels that an adequate weld inspection cannot be performed due to erenssive and/or uneven coating application, he/she shall seek the concurrence of the Level III inspector and then have the coating removed. When it is necessary to measure weld dimensions during the course of an inspection, such dimensions should be determined as accurately as is practically achievable using standard weld inspection j

tools.

Weld inspections are required on field welds only. A Weld Inspeccion Documentation Card and/or a CB&I Checklist may be included in the Reinspection Package.

If it shows any welds in addition to the field welds on the drawing, inspect these additional welds as field welds.

5.8.1 Welds on Integral Attachment to Pipe (8A) i)

Location: Verify that the welds are located as shown on the drawing.

ii)

Size:

Verify the weld size and length meets

(}

or exceeds the minimum specified.

For bevel

\\m -

welds the size is verified by assuring the joint is welded flush. For fillet welds, refer to Attachment 6.3.

18

QI-051 REV. 3 5.0 INSTRUCTIONS (Cont'd)

$s 5.8 Welding (Cont'd) 5.8.1 Welds on Integral Attachment to Pipe (Cont'd) 111)

Fusion: Verify that there is no lack of fusion.

iv)

Undercut: Verify undercut does not exceed 1/32". Record undercut, regardless of size on the inspection checklist. This information is required for verification' of minimum wall during document review.

v)

Surface: Verify surface of Welds are sufficiently free of overlap, abrupt ridges and ripples so proper interpretation of radiographic and/or other required NDE could have been performed.

vi)

Cracks: Verify the welds have no visible cracks or crater cracks.

vii) Verffy welds have no porosity or rounded indications which exceed the following:

r~

i Only indications with major dimensions greater than 1/16 inch shall be considered relevant.

Rounded indication with dimensions greater than 3/16 inch are unacceptable.

Four (4) or more rounded indications in a line separated by 1/16 inch or less from edge-to-edge are unacceptable.

Ten (10) or more rounded indications in any six (6) square inches of surface with the major dimension of this area not to exceed six (6) inches with the area taken in the most unfavorable location relative to the indications being evaluated are unacceptable.

viii) Weld Rust (for Stainless Steel Only): Verify that the weld and the base material two feet on both sides of the weld have no rust colored corrosion product build up which may be linear or localized.

Thin films of surface rust are acceptable.

,~

19

01-051 REV. 3

'5.0 INSTRUCTIONS (Cont'd)

Si r:

.{

5.8 Welding (Cont'd)

V.=

5.8.1 Welds on Integral Attachment to Pipe (Cont $)

,, t!

NOTE:

Materials Engineer will.be available-+ (

in the evaluation of. :.ust

,i acceptability.

ix)

Welder's ID: When the welder's symbol is-

' " 'Nj marked, record it on Attachment 6.19.

If there is no velder's identification visible, indicate so.

>/ l 4

)

5.8.2 NF Welds (8B)

Welds on Moment Restraint Support Structures and:U Bar Restraint bracket welds will be inspected as follows:

3

> s 1)

Location: Verify that the welds are located, i

y as Shown on the drawings. Record on the checklist any welds that are in addition to those specified on the drawing.

(

11)

Size and Profile: Verify'that the weld size and length meets or exceeds the minimum h

specified. For bevel welds the size is d

verified by assuring that the joint'ir? welded flush.

For fillet welds,. refer to attacFaent 6.3.

Unequal leg size convex fillet va'.ds-are acceptable provided that the smal:(r leg "

meets or exceeds the minimum specified:sizq.

For concave fillet welds the theoretical e

throat shall be verified in accordance witl attachment 6.3.

For U-Bar Restraint tracket to support structure weld, record the fillet weld size on the checklist in the remarks column.

>\\

t iii) Fusion: Verify that enere is no lack of '

fusion.

iv)

Crackw: Verifythattherearenovisihh cracks and that there are no linear indications in excess of 1/16 inch.

v)

Undercut: Verify that any undercut drael not.

exceed 1/32".

(

l I,

V

\\

L.

20

.-, 77 -

~[d.

}

F d.. {9.Q 4

A 8

QI-051

%,{t,

s 4

i. ~,e

p ]'

REV. 3

- v+.

,s j

t e

g. }*1

),

3;;.y a

n

~

-5.0 INSTRUCTIONS'scont'd)

~,

.3 s

'['

/ /

-p, y ;#

(

j

'5.8./ Welding (Cont'd) j

)

s

,o

)

,.n

't,., 9.

d5.6.2 NF Welds'(Conc'J)

' '(-

')

j j

i'

.y

'y 8

e

.o vi)

Surface: Verify that the surface of welds i%

99

/

are sufficiently, free of overles abrupt j

,4

/

ridges and ripp Ks so that proper r

t

')

h interpretattrin ot* radiographic' and other 1

i "t

fi required non-destructive exam % ations could

..s

j,*, have been performed.

f f \\*

5 jygg}[ Welder'sID:

When the welders symbol is

,.s d

marked, record it on Atcachment,6.19.

If

.' there is no welder' identification visible,

' 'i - ( t

' 'ddicate so.

'4 9e p

,p3.'

sg 5.8.3 All Orha'r Nrid.s'(8C)

'{3

,)y

.' lt j /

4;

,3

,1.'

O[-

'fo.WCion: Verify that the welds are located

' /s(showti on.the drawin?s'.

m

. h ze (,/7trify t!et the veld size and length,,

11) tl N

meetytpA requirements of the applicable 3

d rau:_rp.gs For 5,erel welds the size is y

j verific6 by 'assurf.ng tha%the joint is welded a

iO 4+

[

/2 flush except as ralted in Attachment 6.18.

Thefollowing'is,powegr, acceptable:-

Filletweldsmay\\eundersizedtoamaximum of 1/!6" provided that, the unders;tzed portion (s) do not excOd 1/4 of the weld l

1ength.

Oversized fillets shall be acceptable if the oversized weld does not interfere with the mating parts.

  • Weld is permitted to have the following underlengths:

Weld length Permissible Specified on Underlength Drawing 43" 1/8" p 3" 1/4"

  • Weld lengths may be longer than specified.
  • The spacing of intermittent welds may vary within 1" of the location specified on the f

drawing.

(

1 21

QI-051 REV. 3 5.0. INSTRUCTIONS (Cont'd) j 5.8 Welding (Cont'd) 5.8.3 All Other Welds (Cont'd) iii) Fusion: Verify that if any incomplete fusion is visible it complies with the following:

  • 'For fillet welds 3/8" maximum incomplete fusion in any 4" segment and 1/4" maximum incomplete fusion in welds less than 4" long.

For groove welds no incomplete fusion is permitted.

iv)

Craters: Verify that the weld size is met on all welds with underfilled craters. Craters outside the specified weld length are irrelevant provided there are no cracks visible through the coated surface if the weld has been coated or on the uncoated surface if no coating is applied.

v)

Profile:, Verify that the weld profiles are,'

acceptable per Attachments 6.17 and 6.18.

vi)

Undercut: Verify that any undercut present

{

does not exceed the following criteria:

For base material 1/8" to 3/8", the following requirements apply:

a.

When the member is welded from both sides and the undercut is in the same plane, the following undercut is permitted.

1/32" for 1/2 the length of the total

or i

1/32" for 1/4 the length of the total

  • weld and 1/16" for 1/8 the length of the total

l

~

Total weld equals the cumulative length of both sides.

22

QI-051 REV. 3 a.

5.0

~~.

INSTRUCTIONS (Cont'd)

(,

5.8 Welding'(Cont'd) 5.8.3 All Other k' elds (Cont'd) b.

For all other welds 'the permitted undercut is:

1/32" for the full length of the weld.

or 1/32" for 1/2 the length of the weld and 1/16" for 1/4 the length of the weld.

For base material greater than 3/8" the following requirements apply:

a.

For members welded on both sides, where the undercut is in the same plane the permitted undercut is 1/32" for 3/4 of the length of the,-

weld and 1/16" for the remaining 1/4 O

of'the length of the weld on both sides.

Y b.

For members welded only on one side or where the undercut is not in the 3

same plane the undercut may be 1/16" for the full length of the weld.

vii) Porosity: Considering that only surface porosity whose major surface dimension exceeds 1/16"shall be considered relevant verify the following:

Tl;e sum of the diameters of porosity do not 1

exceed 3/8" in any linear inch of weld and shall not exceed 3/4" in any 12" of weld.

If 4 or more pores are aligned the edge to edge separation of the pores shall exceed 1/16".

viii) Overlap:

If overlap is present verify that the required weld size and the fusion acceptance criteria are met. If fusion in the i

overlap length cannot be verified then verify that the overlap length, whose fusion cannot Ot be verified, does not exceed 3/8" in any 4" segment or 1/4" in welds less than 4" long.

i i

23 i

__-_______-__A

(-. - _ -

/

QI-051 REV. 3

p.,

5.0' INSTRUCTIONS (Cont'd)

(

5.8 Welding (Cont'd) 5.8.3 All Other Welds (Cont'd) ix)

Slag: Verify that the major surface dimensions of the slag does not exceed li8" or 1/4" for any isolated surface slag. (Slag is considered to.be isolated when it does not occur more frequently than once in a 3" weld segment.)

x)

Cracks: Verify that there are no cracks visible through the coated surface, if the welds has been coated or on the uncoated surface, if the coating has not been applied.

xi)

Welder's ID: When the welder's symbol is marked, record it on Attachment 6.19.

If there is no welder identification visible, indicate so.

e.

"-4 O

i i

24 l

-- A

QI-051 REV. 3 NOTES P;

1.

'In the course of inspection the inspector shall note any item not covered by reinspection / verification which appear out'of the ordinary as related to the construction of the inspected item or surrounding area. Note such in the remarks column of inspection checklist and initiate an out-of-scope observation.

This observation shall be listed on package table of contents and stored with the package in records.

2.

Numbers in parenthesis refer to the attributes on the inspection checklist.

3.

If some components shown on the drawing are missing, initiate a deviation report against " Components".

If all the component shown on the drawing exist, but deviate from other requirements, a deviation report against the attribute " Components" will be written only if the deviation is not covered by another attribute on the checklist.

Example Drawing requires two field welded stiffeners. One stiffener plate is missing.. A deviation report will be.

written for " Components".

If stiffener plate is missing, any' field welds or dimensions associated with subject stiffener n

plates would also be missing. Inspector shall reject other D) affected attributes referencing the deviation report initiated for " Components".

The intent of this note is to avoid multiple deviation reports tha's may be caused by only one deviant condition.

4.

' Drawing, as referenced here, includes all the associated change documents (i.e. DCA's and CMC's).

Information shown on change documents supersedes the drawing requirements.

5.

The inspector should record inspection tool code from.20 on inspection checklist for those tools used in the inspection. The information is for possible future use and is not a requirement for these inspections.

6.

Scope of this QI does not include configuration of grout.

7.

ASTM A325, A490, A449, A320 are high strength bolts. A307 is not a high strength bolt.

8.

For each bolted joint, the Engineer will indicate the type of joint (i.e., bearing, friction or hand tight) on Attachment 6.6 included in the packaFe.

25

4 QI-051-REV. 3' 6.0. ATTACHMENTS j.

(

6.1. Checklist 6.2 Material Identification List 6.3~ Fillet Welds

'6.4 Minimum Edge Distance 6.5 Locking Detail for Hand Tight Connections 6.6 Bolted Joint Data 6.7. Level and Plumbness of Moment. Restraints 6.8 Hilti' Anchor. Designation and Setting Requirements 6.9 Minimum Spacing Between Hilti Expansion Anchors 6.10 Minimum Anchor Clearances 6.11 Minimum Clearances to Embedded Plates 6.12 Anchor, Angularity 6.13 Length. Identification System (for Hilti's) 6.14 Torque Requirements for Friction Connections 6.15 Beveled Washer Detail 6.16 Bumper Shim ~ Details 6.17 Fillet Weld Profiles 6.18 Groove Weld Profiles 6.19 Welder Identification 6.20 Inspection Tool and Codes

'e.

O 26 Ls

Attachm2nt 6.1 QI-051 Rev. 3 Page 1 of 3 ys i

~

00MAWCRE PtAR tt3 Poult !!An Ott:I1'5T I

r r7 AT;su ; Esc

.EttrI,Ar;CN PEG NO.

PIPE WW!F RISTRAtitTS

!a5-PWRt PMt & Of a aCALITT ;5STEWCTION 01-011

@82tm8PtcT10W

[ WIT i symwn M/TM NO.

[ 00C3tNTAft0W RDt!W

[ UWIT 1 O co'a=W

.ncirY.

ATTRISITTE 6

W OAM "8'AIE3

1. fdenettteatten L Locattee

). Ortentacten

4. Configuratten A. Cag ementt
8. Meterials t) P!sti Strength 9

Soltina it) '.'-lar Rest raintw

tti Ockere 9/A 4/A Dec Re"tsw este, seeerd on att 6.2 h

C. Iesta61staea 11 !.evel & Plust U

m eteenete..

tit' seetretne feestfie j

D. Base Platee E. $'a ise t er F.

Attachments

5. Cape A. tRT1reissest
1) Aatteet Temp.

N/A N/A til Svetse Cend.

W/A 4' / A

8. Pa9 e

Pit? u S ST:

AJE sVG 5s S t30 :?'.'Nt Oct.

CA!!

OaTE

.nrh.u III Arrmws.u BY nr..

.a

ATT

'. lag ;N y y!-

3 OA*!

j

.?P* C' !A. Aev'.4 LJe. 3 i

I

Attachrent 6.1 QI-051 Rev. 3 e%

C0!'MCRE P142 RESP'JWit W w"3ECYJ.* ST I

r r.wna mc m;r;a:;an tu wo.

ttrE w ir SEttnatrTs t-s.rwas FAC:L or L i

m :rt aT::s IUI 4.CC FT f RS.*tCT Daft 6.

It ta. -

A. Itse & Nsaber t

Dec. Betten sely, l Joint Detetts N/A N/A "4;;.4 en Attashamet 4.4 i,' Isse

' arena lastina Devise G. But "-

f. Aasher teles A. tithemed temette

& Fim deed Bette t

tse 6 %ubel' 11 eastaa til b;;S:t tw fleDe v1 Tereue wi) Wat fna- -- -

vtt) Thread Enge8 meet l'e t g

  1. tchasede
3. Cenerete tapenetsi i

AacherefPtitt tellis)

() ' tse & Dumhel' si r-l',1 l

easian ammlariev

,v i

.____g----

vi; repetsspot a d hearina

8. Weld W I

A. Telegral attaaksuu4 Walde s

1.m

.v'

_a v.

,g 7 __

v 1 M *=^ttene vi; l'

ilmId Emot Dec. Revice Delf ts) Woldere 19 N/A R 'A tamard es hat. 6.19 i

2 1

J

o e.1 QI-051 Rev. 3

. k

.mC38 7tAK 18370338 !!aJt C u
  • ?.*;ST r;r.' in;M 3&JG iTR;T;;A ;3D Jf.e ac, P!P4 WW!F #fstRAtirts t.8.Pvat 743 Jer y Irt:7:A!!:s ACCFTlRs.*tCT SAft M

'l S. NF Weide t) teeaties

8) flee 6 Profile 1, LI Wueles

',v - Craaka.

Ummt vi; Eurfesa Dog. Battau Only

~'

wit) Walder's TD N/A W/4 a- - M en get. 4.19 C. All othef welds

,'i' saattee 1eil i

us iso

-;rai. ore v

Prot'lle wi' lJaderent v,1) 'F; ;;1ty vi.,11 09efl83 g*

.a ) flaa a) C rassa J

al) Walder's ID N/A WiA g

,gg

\\

t O

a l

,1,

'J'*

e 3

c-----___

..2 QI-051 Rev. 3 Page 1 of 1 MATERIAL IDENTIFICATION LIST

, -s,

)

ITEM DESCRIPTION PERMANENT MARKINGS (Item no., heat no. or unique identifier as applicable) e.

t g

%_,)

l

't A.

'.3 QI-051

{

Rev. 3 Page 1 of 1 FILLET WELDS SURFact CF VC ATICAL W CWSCAS CCNcavt 04lNv(r FIL'.CT WCLC CLL C T

$IZE CF L.

gyggggg er

  • C.3
  • fLO

[

McaiZCNTAL WCW8CR$

h E

TMCC AC TiCAL TMRCAT -

5.:t CF ECUAL LEG FILLET w(LC

  • ELD NOTE. TMC *3iZE* CF AW (CUAL L(G FILLET WCLC 18 THE LENGTM CF TMC LAAC IN$C AlgCD AlGMT ISCSCELf! TRIANGLC. THCCRCTACAL TMACAr eC.T a $1ZC.

SURFACE OF YtRTICAL WCW4(R$

C.:NCAvt o

CONvtX FILLET WELO FILLE T

$ sit CF 2r SURFACE OF WELC wtLC W&

l MCAl2CNTAL WCMSKAS h

i d

\\

TMCCRCTICAL THRCAT UN(CUAL LEG FILLET WELD NCTE FCA UNCCUAL LEG FILLET WCLCS. THE SIZC CF Tht WCLC ts TMC LEG LINC LAAGC57 AIGMT TRI A.ivCLE *Mi:M CAN SC INSCAtS(Q WITMIN THE FILLET 6 TLC FIG. NF4A271 !!Z1 CF FILLET WILOS t.

O CCNCAV!TY If the profile of the fillet veld is concave. verify the staisua theoretical throat per the table below is actAined.

Tillet Si:e(s) y.i., :c: n,:,;.t:a; n, :ay 1/8" 3/16" C.088".(*3/32)

I/'"

0.133" (=5/32) 5/16" 0.177" (*3/16) 3/8" 0.221" (al/4) 7/16"

0. 65" (,*9/32) 1/2" 0,309" (.5/16) 5/8" 0.354"

(*3/8) 3/4" 0.442" (*t3/32) 7/8" 0.530" (*17/32) 1" 0.617"

(*5/8) 0.707" (*23/32)

  • denotes converster.

O

_______a-

- - - - - - - - - - - - - - - - - - - - - - - ' - ~

,.4 QI-051 Rev. 3 Page 1 of I f~)

)

8,j MINIMUM EDGE DISTANCE MINIMUM EDGE DISTANCE (Inches)

BOLT DIA.

(Inches)

AT SHEARED EDGES AT ROLLED EDGES OF PLATES, SHAPED OR BARS OR GAS CUT EDGES 1/2 7/8 3/4 5/8 1-1/8 7/8 3/4 1-1/4 1

7/8 1-1/2*

1-1/8 1

1-3/4*

1-1/4 l

l-1/8 2

1-1/2 1-1/4 2-1/4 1-5/8 over 1-1/4 1-3/4 x diameter 1-1/4 x diameter I.

,s i

\\.J l

1 l

l l

These may be 1-1/4 inch at the ends of beam connecting angles.

l 1

{

\\

()

\\

\\

U j

l j

]

\\

..5 QI-051 o

Rev. 3 Page 1 of 1 M

~

4

+ *4 -

> >.'e.

4,WR

\\

Lil hand l

0

?

X4%

1.n m ta 7-a kivemed op

+

Saate s.s d. na cyk g, 4;, wy i

e LOCKING DETAIL FOR HAND TIGHT CONNECTIONS O

.,6 QI-051 Rev. 3 1

Page 1 of 1

,.Q BOLTED JOINT DATA V

l RESTRAINT / SUPPORT IDENTIFICATION Bolted Joint details:

1 Bolt Identification I

Joint Type l

1 Locking Device Used Is the joint painted D.

(%.

\\s) l 1

l

\\

's_J

..7 1

QI-051 l

Rev. 3 Page 1 of l' I

k C

I q

+3 l O ;l

-]

. c ow 8 *o 7.

1 f

I S00 e

t

~

v

~ W *>=.

g Z, 15 y

D

.Z y

i v

6 4_

d 8

S i

t E5

  1. g 4

y v.

99 p

k a

s

.E:.$.,21 c.

m m

l 1

C l

p. '

1 4

e i

l j

~ Q'?

n_ _.j.

g e.,

AA i

. ::+4

\\

  • 4 /.,%

l i

\\

______________ _____ - _ a

ot nef e R, o m

h1 1 c5 a0 e

~

t - g t 1 a AQP ss e

2 22 26 2

2262 8

28 2

68 22 t n 3

33 31 3

331 3

/

3/

3 1 /

33 uk

/

//

// /

////

5

/5

/

/ 5

//

N c 7

71 1 7 7

7 1 77 7

1 7

77 i

1 1

1 1

1 1

1 2 hT S

T s

N

. d 4

842 2

22 8

42 24 E

ha

/

///

/

//

/

//

//

M t e 4

48 81 4

41 1 1 1

1 1 1

E gr

/

//

/

/

/.

1 1 1 1 R

nh 3

37 71 3

31 1 1 1

1 1 1

1 1 1 2 I

eT U

L Q

f E

o R

G N

I k

T i

T w

E K

S t

n) r D

eee N

mup A

d qu erS N

b o o

O mT I

E.

T e

A

'm r N

uo G

mf I

i e S

nB

~

E i(

8 88 84 8

8844 4

44 8

44 42 D

M K

/

//

//

/

/// /

/

//

/

//

//

I 1

1 5 51 1

1 51 3 1

31 5

1 1 31 R

W O

K 1

1 1 1 2 1

1 1 2' 2 3

23 1

23 24 HCN A

ITL I

H s

8 48 44 2242 4

2 2' 22 e

/

//

//

////

/

//

//

z 5

1 1 33 1 1 31 1

1 1 1 1 i

S 1

22 22 3

l 3333 4

44 5

55 66 as x

xx xx x

xxxx x

xx x

xx xx ut t l 4

48 82 4

4828 4

84 8

24 81 co

/

//

//

/

////

/

//

/

//

/

AB 1

1 3 31 1

1 31 5 3

53 3

1 3 5

noro phmc o

an A

B c

D E

F G

H 1

J K

t A S

I I

lll l

!l\\)1 J

83

'6 v2 t e-.

nRf e

o f

m h1 2 c5 a0 e t - g t T a AQP s

se 2

622 6

t n 3

1 33 1 8 622 22 22 2

2 2

2 uk

/8

///

//

1 33 33 33 3

3 3

3t Nc 7/

771 75

///

//

//

/

/

/

/l i

1 5 2

h 1 '

771 71 71 1

1 1

1 o 2

2 2

T b

1 1

1 1

1 1

1 - e hu t n i

S oa T

s th N

d 22 444 42 444 44 44 4

4 4

4 gd E

ha

//

///

//

///

//

//

/

/ /

/ ne M

t e 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 1

1i r E

gr R

nh 1 1 1 23 d a I

eT 1 1 1 23 23 23 3

3 3

3nf U

L oI Q

f p

E o

s=

R en r

G ra N

or I

k ce T

i r

T w

42 428 28 28 8

8 8

8 earr E

K

//

///

//

//

/

/ /

/b1 S

t 1 1

- ~ -

1 1 1 1 1 1 1 1

n) r 1

1 1 m D

eee 36 368 68 68 8

N mup 8 ~ '8 ud 8na A

d qu n

erS h a N

b o t m O

mT i r m

I E

wa e

T e

A mr d a N

uo eh G

mf pt I

ie m

S nB af E

i(

44 22 44 22 22 2

2 2

st o D

M K

//

//

//

// //

/

/

/

'- ea d

I 31 1 1 1 1

- 1 1 1 1

- 1 1

1 R

W O

K 23 45 23 45 45 5

5 5

r b e HC yn N

an A

mi I

rr T

ee L

t n I

an H

ea rm 22 2

g s

22

//

/

e e

//

1 1 1

d m z

1 1 na i

00 222 33 55 6

8 2

3an S

88 999 1 1 1 1 1 1 1 1 1 1

1 2

2 l

he as xx xxx xx xxx xx xx x

x x

xth ut gt tl 84 21 4 24 21 4 I4 I4 4

4 4

4 n co

//

/

/

//

/

/

/

/

/

/

/

/en AB 53 1

1 1 3 1

1 1

1 1

1 1

1 li 1

1 1

1 I

1 I

I hnce nh i - t

- n 9i 1

n fi n

o or b

o sr ph t o

.l n

mc D

E oe an O

P q

R S

T U

v W

X y

Z D

EBl tA S

\\!1 lI l

I t

....9'

.A QI-051 Rev.-3 Page 1 of 1

. MINIMUM SPACING BETWEEN HILTI EXPANSION ANCHORS *

'Hilti Anchor.-

1/4" 3/8" 1/2" 5/8" 3/4" 1"-

1 1/4" Size Hilti-Hilti Hilti Hilti Hilti Hilti Hilti

-1/4 2

1/2 3 1/8 3 3/4 4 3/8 5

' 6 -.1/4 7

1/2

'5/16-2 13/16-2 7/16 4 1/16 4 11/16 5 5/16 6'9/16 7 13/16 3/8-3 1/8

.3 3/4 4 3/8 5

5 5/8 6 7/8 8

1/8-1/2 3 3/4 4 3/8 5

5 5/8 6 1/4 7 1/2 8 3/4 5/8 4 3/8-5 5 5/8 6 1/4 6 7/8 8 1/8 9 3/8 3/4 5

5 5/8 6 1/4 6 7/8 7 1/2 8 3/4 10 7/8 5 5/8 6 1/4 6 7/8 7

1/2 8 1/8 9 3/8 10 5/8

'l 6 1/4 6 7/8 7 1/2 8 1/8 8 3/4 10-11 1/4 1.1/4 7

1/2; 8 1/8 8 3/4 9 3/8 10 11 1/4-12f,1/2 O

Dimension in inches.

  • .The minimum spacing outlined in the above chart applies to Hilti anchors detailed on-separate. adjacent fixtures.

]

Hilti bolts details on an individual fixture drawing may have less than the minimum spacing tabulated.above, i

l l

1 i

l l

O 1

I

o Attachmsnt 6.10' OI-051 Rev. 3 Page I of 1

,.sg MINIMUM ANCHOR CLEARANCES *

. U MINIMUM DISTANCE TO Abandoned Hilti Anchors or Hilti Richmond Screw Anchors Concrete Edge

  • Holes.and Embedded-Anchor Anchor Size 1-inch 1 1/2-Inch (Note 1)

Bolts that are Cut-Off**

1/4 7 5/8 12 1/4 1 1/4 1/2 3/8 8 1/4 12 7/8 1 7/8 3/4 1/2 8 7/8 13 1/2 2 1/2 1

5/8 9 1/2 14 1/8 3 1/8 1 1/4 3/4

-10 1/8

-14 3/4 3 3/4 1 1/2 l'

11 3/8 16 5

2 1 1/4 12 5/8 17 1/4 6 1/4 2 1/2 8

()*MeasuredCenter-to-Centerofanchorsandanchorcentertoedgeofconcreteininches.

l

    • Minimum spacing between holes covered by 'this column shall be measured center-to-center and based on size of hole being drilled.

(e.g.,_ Pilot hole spacing is based on pilot bit size.)

Hilti bolts may be installed as close as practical to unused Richmond Screw Anchors which have been plugged (i.e., grouted, Richmond Screw-in plug or snap-in plug, etc.).

' NOTE'l: Where embedded angles are used for framing water tight door or removable block wall-openinge, the minimum clearance from center line of Hilti anchor to the opening edge is 5 inches + 5 times the Hilti anchor diameter.

1 l

1

_.___________________________U

Attachmsnt 6.11 QI-051 Rev. 3 Page 1 of 1 MINIMUM CLEARANCES TO EMBEDDED PLATES f'M

\\ )~

Where the embedded steel plates are occupied by attachments within minimum distances shown below, the minimum clearance to Hilti Anchors shall be as follows:

Hilti Anchor Nelson Stud size Edge of Plate to Hilti Anchor to Hilti Anchor 1/4 5 1/4 3 3/4 3/8 5 7/8 4 3/8 1/2 6 1/2 5

5/8 7 1/8 5 5/8 3/4 7 3/4 6 1/4 1

9 7 1/2 1 1/4 to 1/4 8 3/4 Dimensions are in inches.

Distance measured with reference to center of bolts and studs.

Where location of the nearest Nelson Stud can be determined from the "S" stamps on the embedded steel plate, the minimum center-to-center clearance to the Hilti

/'

(_])

Anchor as shown above shall govern. Where location of the nearest Nelson Stud cannot be so determined, the minimum clearance to Edge of Plate as shown above shall govern.

1 Hid' g woe e

~

~f^

Sva Em4Eb ps.c r

m:P I

'D ArrAcumsN T S i

t l

1

.,.12 QI-051 Rev. 3 ANCHOR ANGULARITY l

ANGLE GREATER THAN O*

6.. ANCHOR 15 LESS THAN 6

  • OUT OF PLUMB.

PLUMBNESS GAGE

  • STAMP QN

\\

GAGE i

O r,""'

f 6

fj SURFACE or f ANCHORED PLA I

~

t l

I f

/

=

/

u-

~f

' SPACER PLATES I

)

i Use this or other acceptable device in determining acceptable angularicy.

i O

J

..13 QI-051 Rev. 3 Page 1 of 1

. r'T LENGTH IDENTIFICATION SYSTEM i

I

\\'~'/

Stamp On Length of Anchor Anchor finches)

A 1 1/2 B

2 C

2 1/2 D

3 E

3 1/2 F

4 G

4 1/2 H

5 I

5 1/2 3

6 K

6 1/2 L

7 M

7 1/2 N

8 0

8 1/2 P

9 Q

9 1/2 R

10 S

11 T

12 U

13 l,_s.j V

14 v_/

W 15 X

16 Y

17 Z

18

  • To be used for checking embedment length only I

STANDARD HILTI DATA Minimum Embedment Length of Bolt Diameter KWIK (before torque)

Threads 1/4 1 1/8 3/4 3/8 1 5/8 varies 1/2 2 1/4 1 1/4 5/8 2 3/4 1 1/2 3/4 3 1/4 1 1/2 1

4 1/2 2 1/4 1 1/4 5 1/2 3 1/4

(~'s' x.J

,.. =

-.14

-QI-051 Rev. 3 Page 1 of 1 h g...

.( -

TORQUE REQUIREMENTS FOR FRICTION CONNECTIONS NOTE:-

Requirements for A-325 bolts do not apply to Moment Restraints.

Bolt Type Bolt Size (inches)

Torque (ft-lbs) 70% Torque' (f t-lbs)-

A-325' 1/2.

93' 65 5/8 228 160 3/4 387 271 7/8 518 363 1

725 508 l>

[A-490 3/4 500 350 7/8-650 455 1

1320

.924 l' 1/4 2620 1834 j

1 1/2 4565

--3196 e.

.j O

O

i

..15 i

QI-051 Rev. 3 4

Page 1 of I l

(3* ming' SEVELED 8

WASWi2

/

WA5WER & MUT Ttequirercech\\

d b

/

g YM COWAs ll' L o

%w a u.

L

-/

/

BEVELED WASHER DETAIL O

I 9

o.16 QI-051 Sumpaat hm ba tait.s Rev. 3 Page 1 of 2 1 *(TYP.) pcA sury (M: LESS i

8 '\\

4 he,'(TYP.) FC A SrtlM McR.1 in AN + /

k3^

fi'o' gI

/

,,4 %I PIPA BUMPER r,/

n S-

)

g3HIM GAP g

o

\\

/

I s -.e.

u/A i

/

) f'

)

\\

.l., r 5 TACK c5 WELOEO SHIMST]>p M [wu FVl }i " O 1'##*'

\\. 4( yPg"V f*u

'--~~~ ( MlN. TH X.. !4 ",)

PI P E WHIP RESTRAINT

' SUPPO R T S TR U C TUR E.

,Y

'g*

Q OP EA W PIPE IN Col.0 3

e pc3f 7foy 7

IF THIS SHIM IS 2 CA L155 84 " EP7E CTIV E FAovlDE i

,THACAT AS SMcWN DETAIL. AS SHOWN ON ALTERNATE DETAIL cW4.sr-os7s

"~- -

- T -

NcTE: A-588 WITHoq k

SPEclAL CHEMISTRY l

CONTACL CA A 3G ARE (3

i AcctPTABLE ALTE. ANATE V

'. y MA.IlyIU AL S F.C R_SHJ MS.

m '.y se us su.m.s w < sua.

K 9.

i

-.)c' w) ors e do w t i w u e v t..

vue wsto

) [

' f f tA) l,L't."

To t> C'YP) or l fl!E NHIP 'RE.sTWAlar

'~ l '4 LTYP.\\ f0K SHIM '4 ANp li.Cf SUfPCRT STRULTURE..

.V J-9 W%. \\ Eg'dLTYPMcA SMIN McRE THA.V3' 4

SECT'lON I-1 PROPOSED ALTEkNATE SHIM DETAIL l

FOR REMOVABLE BUMPER (THIS ALTERNATE DETAIL APPLIES TO SHIM CNLY.

ALL OTHEA INFORMATION REMAINS lOENTICAL TO THAT GIVEN ON OWQ. 51 - 057G )

DC A = 13 41S" E'A SHEE T 2. *f I TUSI COMANCHE PEAK I

(%

pgcPOSED

\\

l I

i ALTERNA"E SHIM CEIA!L FCA REMcVASLE EUMPEA I

FIGURE: 4CC

  • ~

s-"~-

s 5 s2n YW.I ft$

czlc m c w.ut.wu w. srA

7. E. issuto Fce.

- 2323 2323-51-0575

.4 Attachmsnt 6.16 QI-051 Rev. 3 Page 2 of 2 4'(T'rp.) PCA SMIM 8

3 " AND Liti 4

N

. s g A '(TT7.) FCA SHIM MCA1.ThAN 3 "7 g

4 g7 f'

i Y.

3 FIP L, b u M P L R yg

\\

I l

t

)

'p,,

6

.s ba W

, ' ~

STACK CP WAL gQid YJIfQ'

/

(, MIN. THM., 8.pIO SHIMS (77p,p a f"

4 4 )

4 FIPE WHlf $$TRAINT i

w itanr STR w.T'ua E

L of Ba RE 9ffE IN J IF DU$ SHIM IS I.

?,.cg) postricN PAoviDE 84* 8#Fictivt, t CR Lib 5 1,TMACAT AS SelcWN DETAIL. AS SHOWN CN CW4. St 0574 0

ALTERNATE DETAlk-

~CT.2 4.... -,7x.er l>

SPECIAL, CHEMISTAY CONTACL CA Ar54 ARE b

,1 ACCEPTA&LE ALTIANATE.

i MATRAIALS PCA Sr:lM5.

i

d. :

.,___j, A 17 Twtr su s M is Less m A w

' 'l - 7 __ _.

s'. wies, Tusw Tut wite U T U.,

T, as chwfadaeue.

9 q,,L M

M19.).

' mp)

PIPE WHIP AESTRAINT.

El.* ##M b,,^# #

suPPom,T STAUCTURE, V3-$WG \\f dTYP.)NR SHIM McAE ThwJ l

SECTION f-1 PROPOSED ALTERNATE SHI DETAIL FOR FIXEO SUMPEA

( THIS ALTERNATE DETAll APPLIES 70 SHlM CNLY.

ALL CTHER INPCAMATioN REMAINS lOENTICAL To THAT'OlVEN CN CW4. 51 0 576,)

D C A 13 4 2 5' R 2 i

TUSI INEET J af 3 COMANCHE PEAX

~

PRoPCSED l

ALTERNATE SHIM CITAll l

FOR FIXEO SJ' MPEA I

s s.sai

"*n"* ca--

Y m p s,s

, I.",g*", FIGURE: 407 y ow. wou AMJ TA 7.E.

Issuto Pea l== 2 3 23 2323-51 C576

Attachm2nt 6.17 QI-051 Rev. 3 Page 1 of 1 LO FILLET WELO PROFIT.f5

._ A.

l 1%

l p Do n o t site h s u r e 1

""d 1

/

V o

Acceptable Convexity

--A Acceptable concavity I \\

g i

{ p.. '--

O

r-e Attachmsnt 6.I8 QI-051 i Rev. 3 P

,, age 1 of 1 GRoovt wtto PacFILES

- 00 not measure o

Cs f

C i

Acceptable Convestty e

i.

Y

('

-1/32 (Underfilled) e.

4 O

l'\\I,'

/

)

c I

l Acceptable Concay1ty or Underfill 1

~

Erinding Depression UN,

\\

7 t/

2

\\

/

t1

\\

/

\\t

.b n

s O

Acceptable

a.19 0I-051

  • ~

Rev. 3 Page 1 of 1 COMANCHE PEAK REVIEW TEAM (7.--)

INSPECTION CHECKLIST v

i WELDER IDENTIFICATION VERIFICATION PACKAGE NO.

RESTRAINT IDENTIFICATION NO.

WELDER IDENTIFICATION 1

i

\\

l j

E i

e, f')

(,)

s i

I 1

l 4

1, 1

i i Inspeccor Date u

QI-029.6, Revision 1 l

\\

4.20-QI-051 Rev. 3 Page 1 of 1 INSPECTION TOOL AND CODES CODE TOOL' AF Angle Finder BL Bubble Level BS Boroscope l-BW 1/32", 1/16", 3/32", 1/8" Wire CG Contour Gauge DF

' Dry Film Thickness Gage ll

.FG Feeler Gages.

FL Flashlight j'

FM Fibre Metal Fillet Gages GG GAL Fillet Gages HL Hi-Low Gage MG Magnifying Glass MI Micrometers MM Mirror MN Magnet PB Plum' Bob PR Protractor SC Slide Caliper' SR 6" Rule ST Steel Tape Measure TG Taper Gage p

TW Torque Wrench UD Undercut Gage (Dial)

UP Undercut Gage (Pit)

VC Vernier Caliper VT Visual Inspection (7

v

,