Revised Proposed Tech Specs for LAR 98-010,proposing Rev to TS Table 3.3.1-1, RT Sys Instrumentation & TS Table B 3.3.1-1, RT Sys Setpoints
ML20210R709
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 08/13/1999
From:
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
Shared Package
ML20210R693 List:
References
NUDOCS 9908170196
Download: ML20210R709 (3)


Text

I l

RTS Instrumentation l

3.3.1 l

i l

Table 3.3.1-1 (page 2 Of 6)

Reactor Trip System Instrumentation i

APPLICABLE I

MODES OR OTHER SPECIFIED REQUIRED SURVEILLANCE ALLOWABLE FUNCTION CONDITIONS CilANNELS CONDITIONS REQUIREMENTS VALUE(a) 1.

Manual Reactor Trip 1,2 2

B SR 3.3.1.14 NA l

(

3(b),4(b),5(b) 2 C

SR 3.3.1.14 NA l

l 2.

Power Range Neutron Flux a.

High 1,2 4

D SR 3.3.1.1 s 111.7% RTP SR 3.3.1.2 (Unit 1) t l

SR 3.3.1.7 s 111.1% RTP l

SR 3.3.1.11 (Unit 2)

SR 3.3.1.16 b.

Low 1(C)2 4

E SR 3.3.1.1 SR 3.3.1.8 i

(

SR 3.3.1.11 SR 3.3.1.16 s 27.7% RTP 3.

Power Range 1,2 4

E SR 3.3.1.7 s 6.3 % RTP Neutron Flux Rate SR 3.3.1.1 I with time High Positive Rate constant a 2 sec l

4.

Intermediate Range 1(c),2(d) 2 F,G SR 3.3.1.1 s 31.5% RTP l

Neutron Flux SR 3.3.1.8 SR 3.3.1.1I l

S.

Source Range 2(*)

2 1.1 SR 3.3.1.1 s 1.4 E5 cps Neutron Flux SR 3.3.1.8 SR 3.3.1.11 3(b),4(b),5(b) 2 J.K.

SR 3.3.1.1 s 1.4 E5 cps SR 3.3.l.7 SR 3.3.1.ll (continued)

(a) The Allowable Value defines the limiting safety system setting. See the Bases fo; the Trip Setpoints.

(b) With Rod Control System capable of rod withdrawal or one or more rods not fully inserted.

(c) Below the F-10 (Power Range Neutron Flux) interlock.

(d) Above the P-6 (Intermediate Range Neutron Flux) interlock.

(e) Below the P-6 (Intermediate Range Neutron Flux) interlock.

COMANCHE PEAK-UNITS 1 AND 2 3.3-15 9908170196 990813 PDR ADOCK 05000445 P

PDR

m RTS Instrumentation 3.3.1 l

Table 3.3.1-1 (page 2 of 6)

Reactor Trip System Instrumentation l

APPLICABLE MODES OR OTHER SPECIFIED REQUIRED SURVEILLANCE ALLOWABLE FUNCTION CONDITIONS CHANNELS CONDITIONS REQUIREMENTS VALUE(a) 6.

Overtemperature

' 1,2 4

E SR 3.3.1.1 Refer to Note 1 N-16 SR 3.3.1.2 i

SR 3.3.1.3 SR 3.3.1.6 SR 3.3.1.7 SR 3.3.1.10 SR 3.3.1.16 7.

Overpower 1,2 4

E SR 3.3.1.1 s114.5% RTP N-16 E R 3.3.1.2 (Unit 1)

SR 3.3.1.7 s113.4% RTP SR 3.3.1.10 (Unit 2)

SR 3.3.1.16 8.

Pressurizer Pressure a.

Low 1(9) 4 M

SR 3.3.1.1 a 1863.6 psig SR 3.3.1.7 (Unit 1)

SR 3.3.1.10 a 1865.2 psig SR 3.3.1.16 (Unit 2) b.

High 1,2 4

E s 2400.8 psig SR 3.3.1.1 (Unit 1)

SR 3.3.1.7 s 2401.4 psig SR 3.3.1.10 (Unit 2)

SR 3.3.1.16 9.

Pressurizer Water 1(9) 3 M

SR 3.3.1.1 s 93.9% of Level-High SR 3.3.1.7 instrument span SR 3.3.1.10 (continued)

(a) The Allowable Value defines the limiting safety system setting. See the Bases for the Trip Setpoints.

(g) Above the P-7 (Low Power Reactor Trips Block) Interlock.

COMANCHE PEAK - UNITS 1 AND 2 3.3-16

t RTS Instrumentation l

B 3.3.1 l

Table B 3.3.1-1 (page 1 of 2)

Reactor Trip System Setpoints Function Trip Setpoint 1.

Manual Reactor Trip N/A 2.

a.

Power Range Neutron Fiux, High s 109% RTP 2.

b.

Power Range Neutron Flux, Low s 25% RTP 3.

Power Range Neutron Flux Rate, High Positive Rate s 5% RTP with a time constant 2 2 seconds 4.

Intermediate Range Neutron Flux, High s 25% RTP 1

l 5.

Source Range Neutron Flux, High

- s 1 05 cps 6.

Overtemperature N-16 See Note 1, Table 3.3.1-1 7.

Overpower N-16 s 112% RTP (Unit 1) s 110% RTP (Unit 2) i 8.

a.

Pressurizer Pressure, Low a 1880 psig 8.

b.

Pressurizer Pressure, High s 2385 psig

. 9.

Pressurizer Water Level-High

r. 92% span
10. Reactor Coolant Flow-Low a 90% tif nominal flow
11. Not Used.

1

12. Undervoltage RCPs a 4830 volts
13. Underfrequency RCPs a 57.2 Hz j

i-t-