MONTHYEARML20211Q4981999-09-10010 September 1999 Proposed Tech Specs Clarifying Conditions of Use Re Analytical Methods Used to Determine Core Operating Limits & Adding Ref to Caldon TR for LEFM ML20211G3221999-08-26026 August 1999 Proposed Tech Specs 4.0.6 Re SG Surveillance Requirements ML20212H0771999-08-20020 August 1999 Rev 6 to CPSES Glen Rose,Tx ASME Section XI ISI Program Plan for 1st Interval on 990820. Page 119 in Unit 1 ASME Section XI of Incoming Submittal Not Included ML20212G0821999-08-20020 August 1999 Rev 4 to Augmented Inservice Insp Plan for Cpses,Unit 1 ML20210R7091999-08-13013 August 1999 Revised Proposed Tech Specs for LAR 98-010,proposing Rev to TS Table 3.3.1-1, RT Sys Instrumentation & TS Table B 3.3.1-1, RT Sys Setpoints ML20211M0041999-08-0505 August 1999 Rev 31 to Technical Requirements Manual ML20211G7401999-07-27027 July 1999 Revs 29 & 30 to Technical Requirements Manual (TRM) for Cpses,Units 1 & 2 ML20209E1861999-07-0909 July 1999 Proposed Tech Specs,Adding Reactor Core Safety Limit Figures to Section 5.6.5 of Ts,Clarifying That Overpower N-16 Setpoint Remains in TS & Reflecting NRC Approval of TRs Used to Determine Core Operating Limits Presented in COLR ML20212J4251999-06-23023 June 1999 Proposed Tech Specs,Revising EDG Start Be Emergency Start Instead of Normal Start Following Loss of Offsite Power ML20195E5401999-06-0404 June 1999 Proposed Tech Specs Pages 3.2-6,3.4-24,3.4-25,3.7-23,3.7-30, 3.8-25,3.9-9,3.9-10 & 4.0-2,provided as Addl Aditorial Changes Supplementing LAR 99-001 ML20195B6461999-05-27027 May 1999 Marked-up TS Pages Re LAR 99-004,changing Plant Battery Surveillance ML20195B6771999-05-24024 May 1999 Proposed Tech Specs Relocating Parameter Limits Allows for Available Operating & Analytical Margins to Be Used in Most Efficient Manner ML20206G7111999-05-0404 May 1999 Proposed Tech Specs Revising Surveillances Associated with Plant Battery & EDGs & Miscellaneous Editorial Corrections ML20206Q0311999-04-16016 April 1999 Rev 28 to CPSES Technical Requirements Manual ML20205Q1681999-04-14014 April 1999 Rev 27 to CPSES Technical Requirements Manual ML20207F3511999-02-25025 February 1999 Fire Endurance Test to Qualify Protective Envelope for Class IE Electrical Circuits ML20203B0011999-01-25025 January 1999 Rev 10 to Security Training & Qualification Plan ML20211C1071999-01-15015 January 1999 Rev 3 to ASME Section XI ISI Program Plan,Unit 2 - 1st Interval ML20198J3171998-12-21021 December 1998 Proposed Tech Specs,Proposing Changes Administratively for Unit 1 & Increasing Licensed Power for Operation of Unit 2 to 3445 Mwt ML20198J2541998-12-18018 December 1998 Proposed Tech Specs Sections 1.0,3.1,3.3,3.4,3.6,3.7,3.9 & 5.0,converting to ITS ML20198J5211998-12-17017 December 1998 Corrected Tech Specs Pages for Section 3.8 to 971211 Submittal Re TS Conversion Application ML20197K0491998-12-11011 December 1998 Proposed Tech Specs Section 3.8, Electrical Power Systems, Converting to ITS ML20196C5361998-11-20020 November 1998 Proposed TS Converting to ITS Sections 4.0,3.4 & 3.6 ML20195F1751998-11-13013 November 1998 Proposed Tech Specs,Revising Administrative Controls Section to Include Configuration Risk Mgt Program Into CPSES TS ML20195F5291998-11-11011 November 1998 Proposed Tech Specs Revising Core Safety Limit Curves & Overtemperature N-16 Reactor Trip Setpoints for Unit 2 Cycle 5 ML20196B8811998-10-30030 October 1998 Proposed Tech Specs Section 3.3 Re Instrumentation ML20154R7861998-10-21021 October 1998 Proposed Tech Specs Section 3.7, Plant Systems ML20154S2901998-10-14014 October 1998 Proposed Tech Specs Sections 3.1,3.2,3.4,3.5 & 5.0 Re Reactivity Control Sys,Power Distribution Sys,Rcs,Eccs & Administrative Control,Respectively ML20154C9101998-10-0202 October 1998 Proposed Tech Specs 4.0.6, SG SR, Adding Definitions Required for F* Alternate Plugging Criterion & Identifies Portion of Tube Subject to Criteria ML20153E2661998-09-24024 September 1998 Proposed Improved Tech Specs Sections 3.4, RCS & 5.0, Administrative Controls ML20237E8461998-08-28028 August 1998 Proposed Tech Specs Pages Re Sections 1.0,2.0 & 3.0 of Proposed TS Changes in 980707 & s,In Response to NRC RAI ML20154C4511998-07-20020 July 1998 Interim Change Request ISI-1R5-01, Unit 1 ISI Plan,Rev 5 ML20236T9931998-07-20020 July 1998 1RF06 ISI Summary Rept First Interval,Third Period,First Outage for CPSES Unit 1, Commerical Operating Date 900830 ML20236J3131998-07-0101 July 1998 Revised Proposed Tech Specs Pages Re Safety Injection Signal & Blackout Signal ML20249C6101998-06-22022 June 1998 Proposed Tech Specs Section 3.6 Re Conversion Application ML20216B2811998-04-24024 April 1998 Rev 13 to Cpses,Units 1 & 2,IST Plan for Pumps & Valves First Interval ML20216E6291998-04-0909 April 1998 Marked-up TS Pages,Reflecting Proposed Changes in Amends to Licenses NPF-87 & NPF-89 ML20216B1471998-04-0606 April 1998 Proposed Tech Specs,Allowing Plant to Continue to Operate W/O Having to Perform Portions of SRs ML20217A3901998-03-18018 March 1998 Proposed Tech Specs Surveillance Requirements 4.8.1.1.2f.4)a) & 4.8.1.1.2f.6)a) at Power Re Enforcement Discretion ML20216H1361998-03-13013 March 1998 Proposed Tech Specs Re Electrical Systems Surveillance Requirements ML20248L3191998-03-12012 March 1998 Proposed Tech Specs TS 4.8.1.1.2f.4)b) & TS 4.8.1.1.2f.6)b) Re Request for Enforcement Discretion ML20216D6021998-03-0909 March 1998 Proposed Tech Specs Temporarily Removing Requirement to Demonstrate Load Shedding Feature of MCC XEB4-3 as Part of SRs 4.8.1.1.2f.4)a) & 4.8.1.1.2f.6)a),for Unit 2 Only ML20203K8621998-02-27027 February 1998 Proposed Tech Specs,Increasing RWST low-low Level Setpoint ML20203J5211998-02-25025 February 1998 Proposed Tech Specs Page to Remove Requirement to Demonstrate Load Shedding Feature of MCC XEB4-3 as Part of Surveillance Requirements 4.8.1.1.2f.4(a) & 4.8.1.1.2f.7(a) Until Plant Startup Subsequent to Next Refueling Outage ML20203J6151998-02-24024 February 1998 Rev 26 to Technical Requirements Manual ML20217P1531998-02-12012 February 1998 Rev 2 to ISI-2R2-01, Unit 2 ISI Plan ML20202B1641998-02-0505 February 1998 Proposed Tech Specs Bases 3/4.7.1.5 Re Main Steam Line Isolation Valves ML20217P2961998-01-30030 January 1998 Rev 5 to Unit 1 ISI Program Plan ML20202E5981997-11-25025 November 1997 Rev 12 to CPSES Units 1 & 2 IST Testing Plan for Pumps & Valves,First Interval ML20212C3881997-10-24024 October 1997 Proposed Tech Specs Re Revised Core Safety Limit Curves & Revised Overtemperature N-16 Reactor Trip Setpoints 1999-09-10
[Table view] Category:TEST/INSPECTION/OPERATING PROCEDURES
MONTHYEARML20212H0771999-08-20020 August 1999 Rev 6 to CPSES Glen Rose,Tx ASME Section XI ISI Program Plan for 1st Interval on 990820. Page 119 in Unit 1 ASME Section XI of Incoming Submittal Not Included ML20212G0821999-08-20020 August 1999 Rev 4 to Augmented Inservice Insp Plan for Cpses,Unit 1 ML20211M0041999-08-0505 August 1999 Rev 31 to Technical Requirements Manual ML20211G7401999-07-27027 July 1999 Revs 29 & 30 to Technical Requirements Manual (TRM) for Cpses,Units 1 & 2 ML20206Q0311999-04-16016 April 1999 Rev 28 to CPSES Technical Requirements Manual ML20205Q1681999-04-14014 April 1999 Rev 27 to CPSES Technical Requirements Manual ML20203B0011999-01-25025 January 1999 Rev 10 to Security Training & Qualification Plan ML20211C1071999-01-15015 January 1999 Rev 3 to ASME Section XI ISI Program Plan,Unit 2 - 1st Interval ML20154C4511998-07-20020 July 1998 Interim Change Request ISI-1R5-01, Unit 1 ISI Plan,Rev 5 ML20236T9931998-07-20020 July 1998 1RF06 ISI Summary Rept First Interval,Third Period,First Outage for CPSES Unit 1, Commerical Operating Date 900830 ML20216B2811998-04-24024 April 1998 Rev 13 to Cpses,Units 1 & 2,IST Plan for Pumps & Valves First Interval ML20203J6151998-02-24024 February 1998 Rev 26 to Technical Requirements Manual ML20217P1531998-02-12012 February 1998 Rev 2 to ISI-2R2-01, Unit 2 ISI Plan ML20217P2961998-01-30030 January 1998 Rev 5 to Unit 1 ISI Program Plan ML20202E5981997-11-25025 November 1997 Rev 12 to CPSES Units 1 & 2 IST Testing Plan for Pumps & Valves,First Interval ML20212E9811997-10-0606 October 1997 Rev 11 to CPSES Units 1 & 2 IST Plan for Pumps & Valves First Interval ML20210S3911997-09-0303 September 1997 Rev 10 to CPSES Units 1 & 2 Inservice Testing Plan for Pumps & Valves in First Interval ML20151L1391997-07-31031 July 1997 5 to Technical Requirements Manual, for Plant ML20141E6201997-06-26026 June 1997 Rev 24 of CPSES Units 1 & 2 Technical Requirements Manual ML20141F8471997-06-26026 June 1997 Rev 9 to IST Plan for Pumps & Valves First Interval ML20136G4361997-03-13013 March 1997 Rev 23 to CPSES Units 1 & 2 Technical Requirements Manual ML20135A8241997-02-24024 February 1997 Rev 22 to CPSES Units 1 & 2 Technical Requirements Manual ML20134C6831997-01-31031 January 1997 Rev 8 to Comanche Peak Steam Electric Station Units 1 & 2 Inservice Testing Plan for Pumps & Valves First Interval ML20134M4371996-11-13013 November 1996 Self Assessment Guide Program Guidelines ML20129A5991996-10-16016 October 1996 Rev 7 to CPSES Unit 1 & 2 IST Plan for Pumps & Valves First Interval ML20128G7661996-10-0202 October 1996 CPSES Unit 1 & 2 Inservice Testing Plan for Pumps & Valves First Interval ML20138B5181996-10-0101 October 1996 Rev 14 to ODCM for TU Electric CPSES Units 1 & 2 ML20117C8461996-07-19019 July 1996 Glen Rose,Tx ASME Section XI ISI Program Plan,Unit 1 - 1st Interval Rev 4 ML20217M1691996-05-24024 May 1996 Rev 3 to STA-750, Check Valve Reliability Program ML20117C6181996-05-0303 May 1996 Rev 1 to Unit 2 ISI Plan ML20117C6141996-04-14014 April 1996 Rev 1 to Unit 2 ISI Plan ML20107J0941996-04-0202 April 1996 Rev 1 to Interim Change Request ISI-2, CPSES Unit 2 ASME Section XI ISI Program Plan ML20107E4471996-02-0909 February 1996 Rev 1 of CPSES ASME XI ISI Program Plan Unit 2 ML20100B9471996-01-24024 January 1996 Rev 21 of CPSES Units 1 & 2 Technical Requirements Manual ML20086C5491995-06-30030 June 1995 Rev 20 to Technical Requirements Manual ML20091L1941995-03-29029 March 1995 Interim Change Request ISI-IR3-003, Unit 1 ISI Plan ML20081F1131995-03-12012 March 1995 Interim Change Request ISI-1R3-02 to Rev 3 to Unit 1 ISI Plan ML20080Q3351995-02-24024 February 1995 Rev 17 to CPSES Technical Requirements Manual ML20078R6371995-02-15015 February 1995 Rev 5 to CPSES Unit 1 & 2 IST Plan for Pumps & Valves First Interval ML20078H8501994-11-30030 November 1994 CPSES Odmc Rev Change Sheet ML20073L6591994-10-0606 October 1994 Rev 4 to CPSES Unit 1 & 2 IST Plan for Pumps & Valves First Interval ML20072C7081994-07-24024 July 1994 Rev 16 to Simulator Operations/Maint Instruction - 010, Simulator Certification Testing ML20069E5171994-05-17017 May 1994 Interim Change Request ISI-2RO-001, Comanche Peak Ses Unit 2 ISI Program Plan ML20029D0711994-05-11011 May 1994 Rev 16 to Technical Requirements Manual. ML20065K1721994-04-15015 April 1994 Rev 15 to CPSES Units 1 & 2 Technical Requirements Manual ML20058E3841993-11-30030 November 1993 Rev 14 to Technical Requirements Manual, Page 2-27, Clarifying Discussion in Table 2.1.1 Notations for Local Test Connections,Vent & Drain Valves & Revising List of Effective Pages EPL-1 Through EPL-4 ML20058C4441993-11-23023 November 1993 IST Plan for Pumps & Valves First Interval, Rev 3 ML20058B5791993-11-19019 November 1993 Rev 14 to Comanche Peak Steam Electric Station Technical Requirements Manual ML20058J9711993-11-19019 November 1993 Interim Change Request ISI-1R2-005 to Rev 2 to Unit 1 ISI Plan ML20056D8161993-08-11011 August 1993 Salp,Directive 8.6 1999-08-05
[Table view] |
Text
- _ _
+
I l
LvMANCHE PEAK STEAM ELECTRIC STATION UNITS I & 2 l
TECHNICAL REQUIREMENTS MANUAL (TRM) i INSTRU710N SHEET (Page 1 of 1)
The following instructional information and checklist is being furnished to help insert Revision 14 l
into the Comanche Peak Steam Electric Station TRM. A description of this revision is provided in l
TXX-93401, dated November 29,1993.
t Discard the old sheets and insert the new sheets, as listed below. Keep all instruction sheets in the i
front of the Effective Page 1.isting to serve as a record of changes.
s Remove Irnert l
Stetiorl l
f 2-27 2-27 i
i k
List of Effective Paces i
EPL-1 thru EPL-4 EPL-1 thru EPL-4 1
I i
)
i l
l 1
i l
I i
9312060291 931129 E
PDR ADocK 0500044S 4
P PDR g
i TECHNICAL REQUIREMENT 2.1 (continued)
TABLE 2.1.1 (continued)
TABLE NOTATIONS
- Identification code for containment penetration and associated j
isolation valves in FSAR Tables 6.2.4-1, 6.2.4-2, and 6.2.4-3.
t
- May be opened on an intermittent basis under administrative control.
The table does not list local vent, drain and test connections as they 14 are a special class of containment isolation valves and are locked l
closed to meet containment isolation criteria when located within the penetration boundary. These valves are subject to the same leak rate 14 i
testing as the other containment isolation valves in the associated j
penetration, including all applicable leak testing exceptions.(see i
FSAR Table 6.2.4-2, including notes).
In addition, if these valves i
are capped (or isolated by blind flange) and under administrative i
controls they are not required to be leak rate tested.
Note 1:
All four MSIV bypass val.es are locked closed in Mode 1.
j During Mode 2, 3, and 4 one MSIV bypass valve may be opened provided the other three MSIV bypass valves are locked closed and their associated MSIVs are closed.
l Cote 2:
These valves require ste m to be tested and are thus not required to be tested until the plant is in MODE 3.
l Note 3:
These valves are included for table completeness; the l
requirements of Specification 3.6.3 do not apply.
- Instead, i
the requirements of Specification 3.7.1.1, 3.7.1.5, 3.7.1.6 3
7 and 3.7.1.7 apply for main steam safety valves, main steam 3
isolation valves, feedwater isolation valves and steam 3
)
generator atmospheric relief valves, respectively.
3 4
Note 4:
These valves are leak tested in accordance with Technical
+
Specification Surveillance Requirement 4.E.1.2.
2
(
Note 5:
10 CFR 50 Appendix J, Type C testing of these valves is 6
l satisfied by the testing of the airlock under lechnical 6
Specification Surveillance Requirement 4.6.1.3b.
6
.i Note 6:
These valves are considered an integral part of the airlock 6
f associated with their respective airlock door.
Therefore, 6
1 they are subject to the controls of Specification 3.6.1.3.
6 l
Note 7:
These valves are secured in position by hydraulic system 6
l locks and/or interlocks and do not require separate locks.
6 i
d-COMANCHE PEAK - UNITS 1 AND 2 2-27 Revision 14 November 30, 1993 l
t
.i i
COMANCHE PEAK STEAM ELECTRIC STATION UNITS 1 & 2 TECHNICAL REQUIREMENTS MANUAL (TRM)
-j EFFECTIVE PAGE LISTING BELOW IS A LEGEND CDR THE EFFECTIVE PAGE LISTING:
{
Original Submitted July 21, 1989 j
Revision 1 September 15, 1989 i
Revit;on 2 January 15, 1990 l
Revision 3 July 20, 1990 Revision 4 April 24, 1991 1
Revision 5 September 6, 1991 Revision 6 November 22, 1991 Revision 7 March 18, 1992 Revision 8 June 30, 1992 Revision 9 December 18, 1992 i
Revision 10 January 22, 1993 Revision 11 February 3, 1993 i
Revision 12 July.15, 1993 Revision 13 September 14, 1993 l
Revision 14 November 30, 1993 e
i t
i i
l I
i i
i EPL-1 November 30, 1993 l
e i
^
COMANCHE PEAK STEAM ELECTRIC STATION UNITS 1 & 2
'[
TECHNICAL REQUIREMENTS MANUAL (TRM) l EFFECTIVE PAGE L1511NG TRM-Tab Original TRM-Title Page June 30, 1992 i
Table of Contents-Tab Original i
Revision 11 Administrative Cnntrols-Tab Original Administrative Controls-Title Page June 30, 1992 0-1 Revision 12 0-2 nuary 22, 1993 0-3
.: ember 18, 1992 l
0-t, June 30, 1992 l
0-5 January 22, 1993
^
0-6 January 22, 1993 0-7 January 22, 1993 l
0-8 January 22, 1993 0-9 January 22, 1993 0-) n January 22, 1993 0-11 January 22, 1993
[
0-12 June 30, 1992 0-13 June 30, 1992 0-14 July 15, 1993 i
0-15 July 15, 1993
(
0-16 January 22, 1993 0-17 January 22.-1993 0-18 Revision 12 0-19 Revision 8
[
0-20 July 15, 1993 i
0-21 July 15, 1993 0-22 Revision S 0-23 Revision 8 0-24 Revision 8 i
0-25 July 15, 1993 0-26 January 22, 1993 Techr<ical Requirements-Tab Original Section 1-Tab Original 1-1 June 30, 1992 1-2 Revision 12 i
1-3 July 15, 1993 1-4 July 15,'1993 1-5 June 30, 1992 1-6 Revision 12 1-7 July 15, 1993 l
1-B July 15, 1993 1-9 July 15, 1993 1-10 July 15, 1991 1-11 July 15, 1993 1-12 July 15, 1993 l
1-13 July 15, 1993
- t EPL-2 November 30, 1993 i
[
~
~
COMANCHE PEAK STEAM ELECTRIC STATION UNITS 1 & 2 TECHNICAL REQUIREMENTS MANUAL (TRM)
EFFECTIVE PAGE LISTING 1-14 July 15, 1993 f
1-15 Revision 12 1-16 June 30, 1992 i
1-17 Revision 12 1-18 July 15, 1993 1-19 July 15, 1993 1-20 July 15, 1993 1-21 July 15, 1993 1-22 Revision 12 t
Sec. 2-Tab Original j
2-1 June 30, 1992 2-2 Revision'12 2-3 July 15, 1993 2-4 January 22, 1993 2-5 Revision 8 l
2-6 Revision 8-2-7 Revision 8 2
l 2-8 January 22, 1993 2-9 Revision 8
~
2-10 January 22, 1993 l
2-11 Revision 8 2-12 Revision 9 i
2-13 Revision 8
[
2-1 July 15,~1993 2-15 Revision 8 2-16 July 15, 1993 2-17 Revision 8 2-18 Revision a 2-19 January 22, 1993 t
2-20 January 22, 1993 2-21 Revision 8
(
2-22 Revision 8 f
2-23 Revision 8 2-24 Revision 8 2-25 Revision 12 2-26 January 22, 1993 2-27 Revision 14 2-28 July 15, 1993 Sec. 3-Tab Original 3-1 June 30, 1992 3-2 Revision 12 3-3 Revision 12 3-4 July 15, 1993 3-5 July 15, 1993 3-6 July 15, 1993 3-7 June 30, 1992 3-8
-July 15, 1993 EPL-3 November 30. 1993 j
. s-COMANCHE PEAK STEAM ELECTRIC STATION UNITS 1 & 2 TECHNICAL REQUIREMENTS MANUAL (TRM)
EFFECTIVE PAGE LISTING 3-9 June 30, 1992 3-10 Revision 11 3-11 Revision 11 Sec. 4-Tab Original 4-1 June 30, 1992 4-2 Revision 12 4-3 July 15, 1993 4-4 July 15, 1993 4-5 Revision 9 4-6 Revision 9 4-7 Revision 8 4-8 Revision 13 4-9 Revision 13 4-10 Revision 13 4-11 September 14, 1993 4-12 September 14, 1993 4-13 Revision 13 4-14 Revision 13 4-15 Revision 8 4-16 Revision 12 4-17 Revision 10 4-18 Revision 12 4-19 Revision 12 4-20 Revision 8 4-21 Revision 12-4-22 July 15, 1993 4-23 Revision 12 4-24 Revision 12 4-25 Revision 12 s
4-26 Revision 12 4-27 Revision 8 l
4-28 Revision 10 4-29 Revision 12 4-30 Revision 10 4
1 4-31 July 15, 1993 EPL-Tab Original EPL-1 Revision 14 EPL-2 Revision 14 EPL-3 Revision 14 EPL-4 Revision 14 4
i EPL-4 November 30, 1993
~
-