Washington Public Power Supply System A JOINT OPERATING AGENCY P. O. BOX 908 3000 GCO. WAIHINCTON WAY RICHLAND~ WAIHINCTON QQ353 PHONK (508) 375 5000 Docket No.
50-397 April 17, 1979 G02-79-70 Director, Office of Nuclear Regulation U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Attention:
Mr. S.
A. Varga
Subject:
WPPSS NUCLEAR PROJECT NO.
2 SUBMITTAL OF LEGIBLE COPIES OF NRC UESTIONS 312.16 AND 331.20
Reference:
- Letter, D. L. Renberger to S.A. Varga, "Responses to Round One questions
- MTEB, CPB, AAB, ETSB, RAB, GSB, HMB,H 3/21/79, G02-79-45.
Dear Mr. Varga:
It has been noted that two of the responses contained in the referenced letter were not reproduced in a clearly legible form.
Attached please find 60 more readable copies of the responses to NRC questions 312.16 (22.048) and 331.20.
Very truly yours,.
DLR:SAG:sg Attachment D. L.
RENBERGER Assistant Director Technolo REGUI IITORY DOCI(ET FILE COPY cc:
I. Littman - WPPSS, N.Y. - wo/att JJ Verderber - B&R, N.Y.-
JJ Byrnes - B&R, N.Y.
RC Root B&R, Site-HR Canter - B&R, N.Y.-
C. Bryant -
BPA E.'hang GE, San Jose - w/att (4)
FA MacLean - San Jose - w/att (1)
J.
Ellwanger - B&R, N.Y. - w/att (5)
NS Reynolds - Debevoise
& Liberman w/att (1)
WNP-2 Files - w/att (1) pX 4~~ e 0$ p@ 0/5/,
~i E
L
Subject:
WPPSS NUCLEAR PROJECT NO.
2 SUBMITTAL OF LEGIBLE COPIES OF NRC QUESTIONS 312.16 AND 331.20 STATE OF WASHINGTON)
)
ss COUNTY OF BENTON
)
D. L.
RENBERGER, Being first duly sworn, deposes and says:
That he is the Assistant Director, Technology, for the WASHINGTON PUBLIC POWER SUPPLY SYSTEM, the applicant herein; that he is authorized to submit the foregoing and knows the contents thereof; and believes the same to be true to the best of his knowledge.
DATED
, 1979 D. L.
RENBERGE
.On this day personally appeared before me D. L.
RENBERGER to me known to be the individual who executed the foregoing instrument and acknowledged that he signed the same as his free act and deed for the uses and purposes therein menthioned.
GIVEN under my hand and seal this IWday of
, 1979.
awed No ary Public in a for the State of Washin ton Residing at
r
MiRP-2 g
312. 16 Provide an estimate, including your basis, of the total amount of hydrogen and methane gases that. can be generated by the radiolytic and chemical decomposition of organic materials and protective coatings under the conditions which would exist following a design base accident (i.e.,
a postulated loss-of-coolant accident).
Your estimate should be limited to those materials and coatings that would be directly exposed to the containment atmosphere.
~Res ense:
The estimate of the total amount of hydrogen and methane gas that can be generated by the radiolytic and chemical decomposition of organic materials and protective coatings under the conditions of a postulated loss-of-coolant accident is discussed in the answers to guestion 022.048.
'j
g DZZ.048 You state in Section 6.2.5.3.1.3 of the FSAR that the corrosion of aluminum, zinc, and zinc base paints located either in the drywell or in the suppression chamber were determined to be insignificant.
- However, we have determined that a potential hydrogen release from the corrosion of zinc following a postulated loss-of-coolant accideet should be considered in the analysis of the to.al hydrogen oroduction
'nd accumulation within the containment.
Accordingly, provMe the following information:
I I
t a.
Provide the corrosion rate as a function of temperature for all materials in the containment that could become a source of hydrogen due to corrosion.
Describe how the corrosion rates assumed for the materials identified in Item (a) were es ablished:
identify ihe experiment 1
data
- base, including the aporooriate references, and discuss the conservatiBNlin the applicability of the data in view of the calculated environmental conditions following a postulated loss of coolant accident.
c-Provide the mass and surface area of zinc paint and galvanized steel and other corrodible materials in both the drys(ell and the wetwel 1.
d.
Provide a graphic representation of the total hydrogen concen-tration inside the containment as a
unction of time with (1) no hydrogen recombiners opera'ting; (2) one recombiner operating; and (3) both recombiners operating.
e.
Provide a gr phic r presentation of the contribution of each source of hydrogen as a function of time.
Oescribe the periodic surveillance that will be done to demon-strate the operability of the hydrogen recombiners and the backup purge system.
g.
Identi-,g the location of (1) the hydrogen samole ooints in the drywell and the suppression chamber; and (2) the suction and discharge points oI" the combustible gas control system wi th respect to nearby structures and equipment.
ZESPdWSE:
,'i rev'eu of "cute conducten to det on Plum'num, g'nc
'or /inc coatings, inaicates that several factors which woula tena to mitigate the evolu tion of hydrogen
'=ollowing a postulated loss-of-coolant accident have not been reportea or have not been investigated.
A brief explanation, therefore, is recuired to sub-
'stantiate the rationale for the conclusions drawn in th' reSponse..
/
~
I
r ~
Question 022.048 asks a question with respect to the corrosion of aluminum and the sub-sequent evoiut'on oz nydrogen.
The water chemistry of
~p/~>'- 3 is such that the water is free from accitives and is neutral,'.e.,
a pH of 6.5-7.5.
Nith reference to Aluminum, Uhlig states:
1 "Aluminum base alloys are not app eciably affectec by dist'ilod wate>>
even at elevated temperatures (up to 180 C
(350~F) at least)
Furthermore, dis-tilled ~ater is not contaminated by contact with most aluminum base. alloys."
Uhlig states:
- "Condensate from steam boilers, if =ree from carryover/of wate" from the boiler, is similarly 'nert to aluminum base alloys.
- Thus, either wrought o" cast aluminum alloys are used success"uliv for s earn radiators as uni" heaters.
hhere aluminum allovs are used
's desirable to install su'table traps in the steam lines, s'nce entrapped bo'ie>> water, especially if alkaline wate" treat'ng compounds a'e
- employee, may be corros'e.
Uhlig states:
"S earn causes a cefinite pro-tective white ziim to form ~ aluminum alloys.
This film is h'ghly pzotective ag temperatures up to 180 to 350 C
(3SO to 500 F).
At tempe atures 0
0 above this rance, under some conc'ions at least, the steam zeacts with aluminum w'th the format'on of aluminum oxide anc hvcrogen. "
Q~c'%A Q opef8%nA Experimental data from the azorementioned rezerences indicate tha,t aluminum ana'luminum alloys are non-reactive witn pure wate~> and/or steam at temperat res up to and inclucing SOO F.
Aluminum rapidiv form' a protective oxide film, in oxycen containing atmos-
- pheres, which is insoluble in neutral ~ater or steam.
Since the containment is noninerted, there is
- free access to oxygen and has been throughout ~ construction.."'--- ~
The o~)ygen nas reacted with the alum'um to form the protective ticht adherent water insoluble and non-reacting fi1m, which
'~:,~~r><~s the Ms-oz hydrogen l:evolut'on at the tempe ature and/or environment present
.during or following a postulated loss-oz-coolant l
~ t
~ I
1 f
- Question 022.048 also adcresses tne corrosion of 'zinc and zinc base paints anc the evoiut'on of hydrogen following a loss-of-coolant accident.
Hubbell and =inkeldy stated:
"L'ke several other metals whicn exhibi" marked resistance to corrosion in the atmosphere br'ght zinc rapidly tarnishes when firs
- exposed, forming a smooth "'ghtlv acherent protective film.
The film is apparently a combina-tion of zinc oxide, zinc ca bonate and zinc hydroxide.
Zt 's not readily soluble in ordinary atmospheric
~aters nor easilv destroyed by other atmospheric agencies.
The film varies in tnickness depending upon the exposure conditions, probably reachinc a maximum thickness of.0003 in.
Zf removed or worn tn'n by abrasion, it is renewed in a few days to its original thickness."
!tciCay and Worthington state in their chapter on Def'ing Non-Corrosive
~neutral Range of Raucous Solutions:
"Zinc has useful resistance only in a relat'vely narrow, neutral range of solution; this resistance be'ng due in the simplest case to a'rotective ilm of hvdrate, abetted in the case of impure so'utions by other precipitated Cor osion products and compouhds deposited : om solut'cn.
The hydrate 's soluble on both the ac'd and alkal'ne sides o'f this neutral zone.
Work by Roetheli, Cox and Litteral has very effec-tively drawn the l'mits of the neutral, hvdrate-forming zone in tests in distilled water witn nydrochloric usec to throw the solu ion acid and~
sodium hydroxide alkaline.
The solutions were kept rather strongly ag'ated."
Figure ~depicts tne results.
oz,z..oh'-1 HcKav and Wortnington explain that:
"The hydrate 6
is seen to have been most protect'e between the neutral point of pHN~and pH~ 2. 5.
The act, is brough" out that the exact shape anc locat'on of tnis curve is typical probably only of the partic-ula set of conditions under which the tests were made.
Factors such as agitation,
- aeration, salts in the solut'on, and temperature, in conjunction witn hvdrogen-ion concentration, affect tne characteristics of film formation.
The investigators conclude in a universal sense the condition of low or negligible corrosion probably lies between pH values of 6 and 8 as a minimum and ll as a max'mum."
(
1
l e
Cox in a paper titled "Effeet of Temperature on the Corrosion of Zinc,", established the efzec" of temperature on the benavior of zinc in aistillec wa ter.
The spec imen s were constantly in motion in the solution, and the solut'on was aerated with a stream of unwashed. air bubbles.
The duration of the test was 15 days.
The results of their invest'gation are shown in Figure 0 p<.048-2
~
Examination of the zinc hycrate film showea trat the strong increase in corrosion coincidea witn a change in the nature o
the film zrom an adherent gelateneous state to a non-ache er.t granular sta.
e.
02%. OM
~ able~1 gives the =esults of the change
'n tne
'm st ucture of zinc w'h respec" to tempe ature.
TaaLE
/~e" 2..0~8-I
',:."""CT OF TE'OPERA URE ON THE CORROSION OF ZINC IN DISTILLED wAT P.
o erne.
erne.
C 0
Cor"os ion Ratp mcjdm /dav mil/vr Appearance o f Corrose on F 'm 68 20 3.9
.78 Gelatenous, very adheren-122 50
- 13. 7
- 2. 74 Less gelatenous, acherent 131 149 167 203 212 65
'5 100 76.2 577. 0.
460 58.7 23.5 15.2 115.4 92.0 11.7 4.7 ilosti t granular, nonage "ent Grarula to flakv, nonacherent Granular laky,'nonadherent Compact
- aense, nonaaherent Uery dense anc acherent
- Ro'lea h'gh-grade zirc,'mmersed for 15 days in water aeratea by air bubbles.
Soecimens rotated at 56 RPH.
~
~
~
~
ttcKay and <lorthington, site work by Bengaugh and 8
Hudson wnich says:
"Of the neutral solutions, d's-tilled water 's re'atively hich in its action on z'nc.
An icea of rates may be gained by tne ol-lowing data, from 24 hou" tests at room temperature on cast 99.97. zinc."
Disti'ed wate" mg.
oe sa. dm. per d v
~ )
~
I Quite suspension Air-agitated A itated with arbon Pioxice 53.
76 167; 199 143
)g'te"et( w'th ei-33 I
I The auti o" s sta" e tnat a fa' average range of ra es in dist'lied wate would be 30 to 200 mg./sq-dm. per cay.
'l
~
I L
I e r L
L ~.
'n estimate of the total amount of hydrogen and methane gases that can be generated bv the radiolytic and chemical decompos'tion o
0 genic (m(aterials anc protective coat'ngs unce" condit'ons which would ex.'st following a postulated
'oss-of-coolant accidentis c-6~5>deed 8 baal au3.
L
~ ~
There ',
to oUr knowledge, no published evperimenta data which szates the amount of hydrogen att ibutab e to the ef fects of a LOCA on specific coatings or organic materials.
There's also no published cata. which g'ves the amount o
methane proauced fro~ the decompos'ion of organic materials in ap5'non~ nerted environment at the tempera"ure and radiation levels resulting from 3 loss-of-coolant accident.
All oL the organic coating materials used within the containment have been subjected to the test reauirements stipulated in AHSi H-101.2 agd AHSZ H-512 and 'to an accumulative dose of 1 x 10
- rads, at the Oak Ridge National Laboratory.
Test results show the coatings were intact with no defects.
E i~lattson s tates:
9 I
"Decomposition of 'Organics:
A substantial amount
- of organic materials is used in protective coating
- systems including those over zinc-based primer paints I inside pNR and BNR containments.
vlhen evposed to the LOCA envi"onment (high temperature,
- chemical, and radiation fields), these organic materials undergo a process o= decomposit'on to form hydrogen and hvdrocarbons.
The Accident Analysis Branch (DS"")
has est'mated the resultant hydrogen and hydrocarbon concentrations resulting from tne radiolytic decom-position of organics and the thermal and chemical eact'on oz organ'c coat'ngs on concrete sur aces.
Assuming a conservatively.integrated radiation exposure of 10
- rads, the Acc'dent Analysis Branch (AAB) estimates the hvdrogen concentrat'on due to radiolyt'c decompos'ion oz organic coatincs to be less than 0. 4~ zor PNR' anc less than 0. 2'o. for BUR'.
, d'or hydrogen generat'on due to thermal and chemical
', reaction of organic coat'ngs on pa'nted concrete su faces.the BAD est'mates the resu t nt hyd ocen I concentrat'on to be less than 0.3% for PhR's anc less than0.2~ for BWR's.
~ f we sum these hydrogen contributions from organic mater'als which were here-tofore not included in our analysis, the additional hvdrogen represents roughly a
10% increase
'n the hydrogen generated f=om all sources previously con-sidered, i.e., 2'irconium water reaction> radiolysis
( of water, and oxidation of zinc w'h its organ' top co/ during tne post-LOCA period.
Since the~e will be a large amount of water, relat've
,'to the amount of organic materials, it can be con-ciuced tha" the hydrogen gas generated from radid-lysis of water should dominate that from decompos'ion
- oz the organ' materials."
W The corrosion rates as a
nc"'ion of temperature for
- . all materials in the containment that could become a
'source of hydrogen due to corrosion are:
P
<> /
3.9
- 13. 7 76.2 577 460 58.7 23 '
Cc rrosion o /scr. ft./da
.0013
.0045
.0250
.1892
.1508
.0192
.0077 Aluminum applies to Peflective insulation around the RPV and +~ping Temp.
70 F to 340
.=
itonreactive, will not procuce hycrocen a" temperature indicated.
- Orcranic Materials Cons'sts of all organ'c coating Imaterials on steel and concrete in drywell and wetwe l.
ito specif'c reaction rates have been published wherein the unc"ion of temperature on tne corros'on "ates of organic mater'als has been addressed.
.'tost data addressed the loss in or de"erioration of pnysical propert'es such as strength, durometer and the like.
A'1 of the materials used for coat'ng of concrete or steel have been subjected to the recrui ed tests stipulated in AiMSI N-101'nd AL'JSI N-512 in accordance with Bechtel Corporation's specificat'ons CP-951 and CP-956, by the Analytical Chem'stry Division of Oak Picge L~1ational Laboratory.
The test reports indicate tnat tnere were no de=ects in the coating materials, '.e.,
there were no signs of chau king, lakincr, crack ng, delamination dr blistering beyond the recu'emen-'s of the acceptance criteria o the ANSI Standa ds.
Refe"ence 9
s ates that "The Accident Analysis Branch (DSE) has estimated the resultan" hvdrogen and nvdrocarbon concentration resulting from radiolytic Cecompos' tion of organics and the the mal and chemical
'eaction of organic coatings on conc ete sur=aces.
Assuming a conlervatively integ ated radiation e:<posure of 10
- rads, th'e Acc'dent Analysis Branch
(~QB) estimates the hvdrogen cor.centration due to radiolyt'c decomposit'on o
organic coa"ings to be less than 0.4% fo" PNR's and less than 0.2'or BNR's.
Fo hydrogen generation c'.ue to thermal and
- chemical reaction of organic coatings on pa'nted I concrete surfaces the AAB est'mates tne resultant
'vdrogen concentration to be less than 0.3r'. fo PNR's and less than0.2% for BNR's."
I
C
'or the specific BhR'in question, we are speaking
,of a possible0.4~
total hydrogen and hydrocarbon concentrat'on.
q
. Q l'~~ gf, paaioiqmc. aQ~
os',
ow e4e-.- 6. 2. 5.
rent m rv~
c he corrosion rates for the mater'ls identified in tern (a) of the question were establ'ned as follows:
I. Zinc Since no def'nit've data with respect to the corrosion rate of zinc in a BNR environment, containing neutral water without additives, nas been reported the test'conducted by Oak Ricce "tational aboratory, Franklin nst'tute Research Laboratories or Brookhaven iVational Laboratory, it was necessary to refer to the investigat'ons conducted by otner,recognized corrosion experts agaj;4gt>cautions.
Figu ei-2 and the accom-panvi..g ao 'er=
explains tne inves tigat'ns con-ductec to dete mine the corrosion rate of zinc (rol'ed high grace)
'mmersed for 15 cavs in dis illed water aerated bv ai r bubbles wh'le rotat'ng the specimens at 56 R>t!.
The table which appea s in the referenced publicat'ons shows tne actual corros'on in milligrams per scua e decimeter pe
'dav and mils per year at the various temperatures.
he data wn'ch was used as a basis for calculat'ng the evolution of hydrogen is actual measured data.
/
The premise that all oC the metal which corrodes will react to produce a stoichiometric quantity of hydrogen is ultra conservative, s'nce there are other competing reactions which will produce zinc carbonate and ~inc oxice.
in our evaluation we determined the highesc corrosion rate of zinc occurred at 149 : and resu'"ed in a ra e
o 577 mg/dm./day or 89 ozfsq.ft./dar in our analysis we used this max'mum amount as the corrosion rate, at temperature, in the containment..
it can be determined from the published data that ~~is is conservative by a factor of more than 27~
if we cons'der that at 212 F the corrosion rate is 23 5 mg/cm./day or.$ 077 ozgsq.ft./day and that at 68 F '" is 3.9 mg/dm./day or.0013 oz/sq.ft./day.
The data oC Figure -2 and Table, 1 show that at the tem-perature of 149 F the max'mum 'rate occurs and that the rate falls sharply witn temperature inc"ease so that at a temperature of 340 F it would be below tnat shown at 212 F.
4
g,,:Aluminum Our search of the literature (1),
(2),
"(3) clearlv indicates tha" aluminum will not
,corrode or produce hydrogen since the pH of the
'water is in the neutral range and the temperature is below that required to produce hydrogen.
, Wha,
~ ".'"..".. "
'.,'"Q:;-:Or anic Coatings and Materials
~.
~3.aterazureY in an effort to determine iC there was
'any "irm data which showed that the organic coatings and materials used would produce hycrogen as,a result of a postulated loss-of-coolant acc'dent.
""-" gt nas been postulated that organics
- do form hydrocarbons as a
esult of radiation> but this theory is based on tne fact that there i~s a
loss of physical properties as radiation e:exposure increases.
Ne have stated
- "...". that the organic top coats anc coatings used within conta'n-
.ment were subjected to tho test recu'ments of IANSi i4-10). 2 and iVLlS" H-512 "o an accumu'at'e cose
,'of 1:<
10
- rads, with a resulting no deCects.
AnaIq&iS ilattson states tnat "The Accidentv Branch (DSi) has estimated tne esultant hycrogen and hydroca bon concentration resulting from the radiolyt'c decom-position of organics and "he the mal and chemica reactions of organic coatincs on concrete sur=aces.
IAssuming. a. conse vatively integrated radiation ev-Iposure of 10 rads".g to be less than 0.2'4 for B'i'B's.
He fu ther states anat therma'nd cnem'cal reactions are estimated to produce
,',less than
- 0. 2% of hydrogen or Blvd's.
~.
C~
- The mass and surface area oC z'nc pa'nt, galvan'zek
- stee',
's as fol'ows:
I Zinc Paint 280,853 sq. ft.
18,367.8 lbs. of zinc in drywell and wetwell above the water level Galvanize 67,483 sq.
3018.3 lbs. of galvanize drywell and wetwell above the wate" level Alum'um 460,700 sq. ft.
32,374 lbs.
around reactor
~ pressure vessel and pip'ng
I
+, Organic Topcoats
,On I
I On steel 400,000 sa. "". - approx.
187,500 lbs.
concrete 33,000 sq.'t.
approx.
24,750 lbs.
h1 I+h
~ The graphic representation of the total hycrogen concent, ation. inside containment as a function of time is shown in figure k.
The graphic representation of the contribution of each sou ce of hydrogen ~a unction-of time is sho~n in r igures 3 o< 4 as U
~
1 I
FThe pe"
'stra te
'the bac LL iocic surveillanc the'operability o
kup purge sys em
"":.:" 4 Z.l.l 8<nc}.
Ih lhA e that wi 1 be done to demon-f the 'hydrogen recombiner and iOCLL,SS
<.z. -.""
gqThe location of the nydrogen sample points in the Idrywell and the suppression chamber and the suet'on and discharge points o
the combustib'e gas control system with respect to nearby structures and eauipment
,'s been answered '" "'- :":.. in resoonse to
,:'Ques tion~~.
~zz. zK.
s~
pages
~-
F ~~a.
~uiskJ pe
~ I
~
~
I I
C>
BiBLiOGRAPHY QQ QZ.Z.Qqg The Corrosion Handbook H.H. Uhlig p.
42, Pub. J.
Weley
& Sons The Corrosion Handbook - H.H. Uhlig p.
43, Pub. J.
Neley
& Sons The Corrosion Handbook H.H. Uhlig p.
- 617, Pub. J. Neley
& Sons Corrosion Resistance of Hetals and Alloys R.
HcKay R. Worthington p.
- 168, Pub.
Reinhold Pub.
Corp.
Corrosion Resistance of Hetals and Alloys R.
i~1cKay R. Worthington p.
- 159, Pub.
Reinhold Pub.
Corp.
Corrosion Resistance of i'",etals and Alloys - R.
NcKay R. Worthington p.
- 169, Pub.
Re'nhold Pub.
Corp.
Corrosion Res'stance of i'letals and Alloys R.
HcKay R. Northincton p.
- 159, Pub.
Reinhold Pub.
Corp.
Corrosio'n Resistance of Hetals and Alloys R.
NcKay R. Worthington p.
- 163, Pub.
Reinhold Pub.
Corp.
7 U. S. N. R. C.,
l!emorandum 10/17/78, R. J.
Mat tson, Directo",
Division'of Systems Safety to R.S.
Boyd, Director, Divis'on of Project 51anagment (Available tfRC Public Document Room) dZZ.Odg Fig.~ 1 p.
160 i'".cKay
& 'Worthington p.
13 Zinc:
ts Corrosion Resistance Pub.
Zinc inst'ute Fig. 2 p.
161 HcKay
& Nor nington azz;04g-p.
104 Zinc: its Corrosion Resis
- ance, Pub.
Zinc insti tute
'~~8 p.
232 LaQue' Copson - Corrosion Resis"ance of i~~etals and Alloys
/
O X,Z.d48-Table" 1 p.
160 HcKay
& Worthington p.
233 Lague
& Copson - Corrosion Res'stance of bietals and Alloys p.
103 Zinc: Its Corrosion Resistance, Pub.
Zinc institute Conversion Factor H.
H. Uhlig
~ he Coirosion Handbook p.
1160 Table 19 Final Report F-C4290, Hydrogen Evaluation From Zinc Corrosion Under Simulated Loss-Of-Coolant Accident Conditions Franklin institute Research Laboratories 8/76
%a l
~ =
4 7
1
~ 'I a
~
ZZO 2.00 leo I 60 c AND Z )NC co@, lNcj3 z
O Q)
~ W
~-
0 z
0 Ql Q
2
)J O
0 U
uJ2 g )40 i-g IZO 0
.IQO 0(r ao)
HCl Nc OH.
6Q 40 2.0 0
0 WASHINGTON PUBLIC POWER SUPPLY SYSTEN NUCLEAR PROJECT NO.
2 E.F Fc.Ci OF pH ON COF,ROS ION RA'TE. OF F'URF. Z.INC iN 0X, (6E.NP,Y I= D SOKUT'lONS P ICURE Og7.~y 1
I I
500 500 4-00 K
Q 0
V)0 0 0 g 2,00 I OO IOO ISO 200 250 7E.MP ERAYURl= F WASHINGTOiV PUBLIC POWER SUPPLY SYSTEM iVUCLEAR PROJECT NO.
2 ZINC vs DlST tLUF.O WATF R E,FFC.GT OF TEMPFRKTURE.
ZrGURE dgg. &9-
V
lA O
n C
m Xl f A
O o Pl m
Al O
a g
IO" I
M-W SOURCE DRYWELL BADI OLYSIS SOU ACE Sur VnESSION CHAMBER rg a~+ rn
/PI.
p PlRQ~
~ Z Do<
iO
~2,o Z-~n zrz Pl
~-= rj
~gz
~O
~ Ci oP
~o Z
ha0 4! Q~
C
~gW
~ IO 0
IO IO RA0 IOLYSI S SOU BC E DAYNELL IO TIME (SEC)
IO'lOTE:
THE COHTRIBUTION OF THE RADIOL(TlC AND THERh1A.L DECOMPOSlTIOH OF ORGAN IC TOP COAT5 IS IHCLUDEQ IN THESE CURVES.
n, 4
I%3 '
I O
n Im g
CQ n
CO m o n
Dl x$
cn O
~
go fO g
(/1 Ul
-g m
5 ~O
~ O~.
~m mr W g
<0 l Z{fl m-0
~X)
-n >(n
-l py
-< O~
g X m~
r~
lrl O) g lQ CL Cl
~O'2 NOTE: I.OOTTEO uVE REPRO'.5E.V TS AV IVCReASE IH H, GENEAATlON FROM, Tll'E RAOlOLVTlC fj THE,RMAL DECONPO5lTLON OP ORCgANlC TOP COR,TS AHO P N INCR' 5E RE'50LTlH6 IN llg EVOLUTION FRObl 'ZiHC usll4C A COHSERVAliVE. ESTlMATE BA5ED Ohl A.'0hlC" DRY AHA.L(5l5.
2.SOLlo Llt4E. REPREGEHTS Hg GKHERKQOt4
'IwlTHOUT OBGAHlCS AND ZlHC NO BECOMBINER SUPP RESSION CI IAMBER NO AECOMBINEB DBYwELL
/
l50SCF M
~C RECOMHINER FLOW START (2,75I-IAS)
//
/
//
I05 SCFM IOS SCFM I50 SCFM IO~
lO4 TIME AFTER LOCA (SECONDS)
%a
NNP-2 Al"KiVDi41ENT NO.
2 December 1978 k.
The system is designed to meet qualitv assurance, redundancy, power supply and instrumentation re-quirements for an engineered safety feature system.
1.
Since the system is redundant and is not shared with other nuclear units, transporta-tion of the hydrogen recombiners is not re-quired.
m.
Since all components of the system are redundant, a containment purge system as a backup is not re-quired.
A containment purge system used for other environmental controls is discussed in 6.2.1.1.8.
6.2.5.2 System Design P
~ he containment atmosphere control system prov'des effective control of the hydrogen generated following a postulated LOCA.
Piping and instrumentat'on for the system is shown in Figures
- 3. 2-17,
- 3. 2-15 and 3. 2-6.
Equ'ment details are given in arable 6.2-17.
.he system consists of the following:
1.
A hydrogen mixing system which operates to
~
assure a well.mixed atmosphere in both the drywell and suppression cnamber.
This system is the containment spray system and can be ac-tuated approximately 10 minutes after the postu-lated LOCA.
2.
A hvdrogen concentration monitoring system measures the amount of hydrogen in the drywell and suppression chamber atmosphere.
3.
Two 100 percent capacity hydrogen recombiners, one of which is manually initiated approxi-mately X.75 hours8.680556e-4 days <br />0.0208 hours <br />1.240079e-4 weeks <br />2.85375e-5 months <br /> after tne accident to preclude the hydrogen concentration from exceed'ng four percent by volume.
The recombiners, are cataly-tic type hydrogen oxygen recombiners.
6.2.5.2.1 Hydrogen i~1ixing System The function of the hydrogen mixing system is to provide a
well mixed atmosphere in the drywell and suppression chamber.
6.2-72
l C
I
mp-2 AMENDMENT NO.
2 December 1978 The cooling water supplied to the aftercooler 's returned to the standbv service water system.
The cooling water supplied to the scrubber is discharged to tne suppression pool.
All components of the containment atmosphere control system are redundant.
Controls include the control panel located in the main control room and the local control panel for each recombiner located in environmentally suitable rooms in the reactor bu'lding.
All of the functions necessary to control tne system are located in the main cont ol room.
6.2.5.2.4 Containment Purge Since active and passive components of the containment atmosphere control system are
- edundant, containment purge as a backup system is not recuired.
- 6. 2. 5. 3 Design Evaluation Based on the assumptions of the model described below, it is calculated that the hydrogen concentrat'ion in the drv-well eventually reaches 4$ bv volume approx'mately 10.0 hours0 days <br />0 hours <br />0 weeks <br />0 months <br /> after the postulated LOCA if the hydrogen recombiner
'is not in operation.
The recombiner is started,
- however, when the hydrogen concentration reaches approximately 3.5% by volume hours after the postulated LOCA) to 1'mit the hvdrogen concentration 'below 4% by volume.
Figure 6.2-26 shows the drywell and suporession chamber hydrogen concen-tration as a
unction of time, with and without operation of the hydrogen recombiner system at design capacity of 150 scfm and at 105 scfm, minimum flow reauired to maintain the hydrogen concentration below 4%, by volume.
The determ'nation of the time dependent hydrogen concen-tration in the drvwell and suppression chambe" atmospheres is based on a two-region model of the primarv containment, a drywell and a suppression chamber atmosphere.
The drywell and suppression chamber free volumes contain air and water vapor at atmospheric pressure just prior to the postulated LOCA.
Gases considered available for hydrogen dilution are the non-condensibles and water vapor present during normal operating conditions.
Water vapor generated from blowdown is not considered.
The radiolytic generation of free oxygen is added to the total inventory of gases.
The pressure in containment is assumed to remain at atmospheric pressure and the temperature history of<,
Figure 6.2-7 curve a; is used.
The. h~dmq~ u~+ibmO~
4am zinc. and. oman'ice boo V no neZR-4e 3'Ao~or.
6.2-76
I S
NNP-2 P21EN'3 Dece M 'NT NO.
2 b r 1978 l
BM'~~~pa~
O'A
- 6. 2. 5. 3. 1. 3 Corrosion"o f Containment materials and ~~041'HOG The corrosion of containment materials was conside ed as a
otential source of hvdrogen.
The corrosion of aluminum, zinc, ~+zinc base paints~vlocated either in the drywell or suppression chamber was evaluated as a potential source of hydrogen.
l l
4 l I 4 l
- e. radielqha.Bnd c,he.w'< e.a,l deca~poihien 1
n~aaic.
Waver>ale m+A
~
Aa Jl r
Vll 4 ll I
I
~
I 4
AVWA I
A C
l
~
~IP el ~
kl mW
, n Ho
+ ~ l%
~l I
~
M f v ~
lM
~ a a I lie I
~ I l ~l 6.2.5.4 Test'ng and Inspections The hyd ogen recombiners and the associated instrumentation are periodicallv inspected and tested to ensure reliable operation.
Eacn hydrogen recombiner system has been shop tested.
Nritten test procedures and acceptance criteria were establisned for all tests.
Test results were recorded 'n performance records.
The full scale performance tests were accomplished by placing eacn unit in operation, starting the hydrogen recombiner ana allowing atmospheric air, hydrogen and steam to flow through the unit.
A flow of at least 155 SCFN was maintained through-out all tests.
The simulated environmental conditions (temp-
- erature, pressure ana hvdrogen at 0.5 to 4% by volume) ol-lowing a postulated LOCA (Figures 6.2-6 and 6.2-7, curve c) were used during these tests.
The manufacturer nas also conducted a series of cata ys" per-formance tests including the effect of ioaine and methyl ioaide.
i<e. e.ualss4on
~O
~ O~
~rn
~ m~
cz~
z np gn M~
~ Zim 2'n
-i C)~
zz m~ n gi n
)W r Q> m ill O
lQ LLI CC Ci 0-
~O 0 2 I02 NO BECOMI3INEB DBVXELL NO BECOlv18INEB SupPBESSION C I.IAh18 E B
/x
//
I50SCF M BECOMBINEB FLOE START (2,75HAS)
IO~
IO4 T IME AFTEB. LOCA (SECONDS)
NOTE: I.DOTTED LlhlE REPRESE.hlTS AH INCREASE lhl H2 GENERATION FROM, TllE AAOlOLYTlc $ THERMAL OECoWPOSnioN OF ORG~HlC ToP COTS AI4D P N IHCRGA5E REQULTlh16 Ihl lt p FVOLUTlOH FROM ZNC U5114C A CoASERVPl'iVE. ESTIMATE BA5ED Ohl A"eoHC'RY AHA.L(SI'5.
h5OLIO LII4E. RFPRESFHT5 Hg GFHER471014 W1THouw oRC <OIC,S AND ZINC I//
I f
W
ill C) n m
I C
g CD Cl O
-go m m 4/l O
o a
g lU 0
IO I
M-e SOURCE DRY@Et L RADIOLYSIS SOuACE SUPPRESSION CHAMBER BADIO LYSIS SOURCE DAYM/ELL rn 8p~
,'F~
1 p mX'0 U p,Z ~
Qo ~
C O
~B U>
+~As z'
G' 0
z ri z
C
]<. g re>
0 IO IO IO ViMZ (SZCI IO IQOTE:
THE COHTRIBOTIOhl OI" THF RADIOL'(TIC AND THERMAL DECOMPOSITION OF ORGAN IC TOP COATS IS INCLUDED IN Toe.GE CURVES.
AN P-2
(}
331.20
~12. 4.
1 )
In addition to the job group exposure breakdown in Section 12.4 of the FSAR, provide a profile of the estimated annual man-rem doses at the MAP-2 facility broken down by major functions such as operations, maintenance, radwaste
- handling, and inservice inspection.
J'ing experience from operating boiling water reactors, provide estimates of doses resulting from non-routine or special maintenance activities.
Indicate the estimated dose rates, the expected required number of workers and the occupancy times required or performing such main-tenance work which you used in evaluating the estimated annual can-rem doses.
Regulatory Guide 8.19 provides guidance in ttiaking such an assessment.
~Res onse:
See revised Section 12.4.*
The tables in revised Section 12.4 provide a profile of the estimated annual man-rem doses at the
'HHP-2 facility.
The tables are based on operating BWR experience and are ormulated in accordance wi th Regulatory Guide 8. 19.
/
- Draft changes attached.
h C
~
12.4 DOSE ASS"SSM"NT 2.4.1 DESIGN CRIT RIA g OCCUPANC ACTORS AND I
PERSONNZL DOS"
/
I r
Th criteria for the dose to plant personnel. during normal ope ation and anticipated ope at'ona.l occurrences, includin ref cling, are based on the reauirements discussed in 10CrR Part QO.
The design radiation 3.evels during normal operat'o and re>ueling are shown on Figures 12.3-$'o 12.3-6.
In areas s ch as the control room and offices, the maximum dose rate doe not exceed 1.0 mrem/hr (Zone:I radiation level)
=o persormel who work in controlled x-'ad'ation
- a. eas, rad-ia ion Zon II through U on Figu es 12.3-1 to 12.3-6, administrati e controls ensure that 4oses do not, exceed the reauirements f 10CP'R Par" 20.
/
The'ccupancy
= ctors used in estimating plan pe sonnel ra-diation exposure are 3.is ed on Tab3.e 12.4-3. for the six per-sonnel groups.
//
. /
a.
Group 1
includes ma'ntenance personne3.
such as mec anical, electr'cal ins rument cra,=tsmen and =or men.
Th'ere are approx'ately 46 people r
b.
Group 2
inI2:ludes control and.ecuipment operators.
There are app ox'ma e'y 29 people in this grou Co d
e.
Group 3
incl 'es technicians such as health phys'cs and chem" try technicians and eng'neer-
'ng assnts.
e are approximately 8
people ia
'ais gro Group includes wginee s
and technical supe vj sors.
There a~@ approximately 9 people in th s group.
Group 5
includes inplant supe=visors such as ealth phys's-chem'tay supervisor, shift su erviso, etc.
There arh approx'mately 14 people in this group.
f.
zoup 6
'ncludes adminis r "'ve and.~nage.-,
~ ment personnel.
Th'ere
.a. e app oximately. 21...
people in &is group;:'
- '2.4-1
use occupancv actors a
e determin'ed by estimating "he
@nounts of t'me spent by personnel
'n controlled ad'ation
/areas while performing the following functions:
J g ~
Rollixne patrol h.
Pe 'odic tests and op@rations l
i.
Con"
.i o t's ml room o era xo j.
Refueling
//
//
k.
Maintenance I
1 l.
Zn-service inspec ion ITable 12.4-1 also lists/0'e estimated annual dose that will apply to a part'cv~lar group 'n a particular area.
To f'nd the cose "hat wil" apaly to'ya pa ticula group, the jose rate is multip~~ed bv the occupancv factors and the num-ber of people in each group.
The results, listed 'n Table 3.2.4-1, represent khole body exposure.
Da"a on personne exposure
=rom ape ating BWR plants show Bat he opera."'on and main-'enance requirements of all BWR I,'3.ants are s~~m'1ar, It '
antic'a~ed that "he ope ation asd ma'ntenazze ecui ements o= WNP-'2 will be similar to o'P.her BHR pl~its and here ore -'se
~h sonnel exposure data wali be si~le 12.4.2 d'sc sses pe.sonnel exoosu e based on BWR ope at'ng expe ience.
~ %
~ 0 12.4-2
12.4 DOSE ASSESSMENT 12.4.1 DESIGN CRITERIA The criteria for the dose to plant personnel during normal operation and anticipated operational occurrences, including refueling, are based on the requirements discussed in 10CFR part 20.
The design radiation levels during normal operation and refueling are shown on Figures
- 12. 3-1 to 12. 3-6.
In areas such as the control room and offices, the maximum dose rate does not exceed 1.0 mrem/hr.
(Zone I radiation level).
For personnel who work in controlled radiation areas, radiation Zone II through V on Figures 12.3-1 to 12.3-6 administrative controls ensure that doses do not exceed the requirements of 10CFR part 20.
~
h
Of the corrosion pro-duct isotopes, Co-60 is believed to be the single most impor-tant rad'nucl'e.
The variables that have been found to affect plant pe sonnel exposu e inc'ude the following:
a
~
BWR plants show an increase in otal personnel exposure du"ing the first few years of operation.
The need to minimize plant downtime reauires that inspec"'on and repair tasks must be sta ted immediately af er plant shutdown when the dose ates from shor -'ived radionuclides can be significant
~
c.
Plan design and ecu'pment layout has a signifi-can ef ect on personnel dose.
12.3.1 discussed the design fea"ures used to minim'ze plant personnel exposure.
d.
T a,'ning and experience o
plant wo ke s.
e.
The extent of maintenance operations reauired or a specific year.
The extent hat a ut'lity uses non-regular or con -actor personnel.
12.4.2.2 Pe sonne'ose
=rom Operating BWR Data References 1 and 2 provide a tabulation o
pe sonnel exposures for operating BWR's.
Table 12.4-p tabulates the average per-sonnel exposure or several plan"s operating for a period of several years
~~s~8 o~
Mesc
~+e~r c.es R ~+cI c~c.es y4~ouqh
'7 p roving'
~or'e I'e-c,e~<
w~o~~~Vio ~
7~
~sscs~<<+
Sec.+i><
l~. q. 2. 3 i>cled e S
~.f c c g%
io4+r"~wb.
~,
='I',
~
~ +
~
1'2. 4-3
NNP-2 A ~ abulation of the ave age fraction {in percent) of th an.
al plant exposure is listed on Table 12.4-3.
Th'able sho~
that the jobs 'isted account
=or 47% of tne <<Xzal dose rece' by plan personnel on the average.
The~emainina exposu" can be largely accounted or after con dering m's-cellaneo~ routine operations and maintenance Each of the tasks in thi,s category are insignif'cant as ar as radiation dose is conca ned.
However, the cumulativ dose received by plant personnel, a
e" performing manv o
hese tasks becomes s'gn'cant.
D+a show that the erpos e from routine oper-a"ions is approxima ely 33% of the t al annual exposu e.
The remaining 20% of th total annual posure is accounted for a ter considering mis'llaneous rk dur'ng outages, bias in account'ng for exposur 'nd d'erences in dosimetry results, It is concluded that no s
le source o
exposure is dominant at ope ating BNR's.
The a
est single sources were the re-circula ion pumps inc~
'ng c ~an-up sys em and work on valves, part"'cularlv rel'e..
nd safety%ah.ves.
Each of these sources cont ibu ed 8% to ne to"al annual exposure. 'nservice in-
- spection, lingui as e treatment systems and uel handling con"ributed t'ex highest exposu" s, 4.9%,
5.6S and 5.5%
of the annu
- exposure, respect'vely.
Noae o
e above d'cussion 'cludes the dose received by con""
or personnel.
Looking at Table 12.
2, subtracting the olumn labeled "regular-man-rem" from "t "al-man-rem" vi ds he cose received by cont ac or personn l.
Zn general, significan fraction (between 25%
and 60~)
o= the total an-rem is received by contractor personnel.
s a
12. '4-4
. 4.2.3 Resul s
ana oncxusxon P.s c.'t:ssed previouplv, a precise estimate
=.
occupa 'nal expose>e o
spec'='p in"ividua3/s is not at"a. nable.
~ gross assessmen is provided '.; the ollow'ng pa" graphs
=or he s'x
'ob group classifications de inec in 1.4.1.
a.
Grouo l - Ma'ntenance pe s nnel would rece've i
r 4
"he la eeet/dose of any o
the sir g oups.
Based on taM data d'scus ed 'n the
'eceding sect'ons,
" e average an ual perso el dose for all p a.nts with
- a. -. ermal outa g ea e
than 50, 00 YiWD is 140 anrem pe year per plant.
he plan-s con idered are 1' ed on
",.Table, l.4-2 l~. f-
.3
I 0
0
WNP-2 ~
From Table 12.4-3, it is seen that maintenan operat'ons, which-include, control rod drive, recirculation pump, valve, turbine, fuel pool and condensate demineralizer maintenance oper-a ions';. would account for 21% of the average annual personnel dose.
Xf one-half of the dos/.
from rout'ne operat'ons (33K) and miscellaneaus work during outages (20%) also is received by plant maintenance personnel, approximately/50%
of the total, annual average personnel dose',
or 70 man-rem,
's received by this group.
issue'ng 46 people are 'in this g=oup results in a dose
/
o 1.52 rem per'iperson annually.
As d:sc ssed in 12.3..1, the equipmen desi gn and layout and the shielding design are such that th'e exposu e
's as low as reasonably ach'evable.
b.
Groun 2
Plant ope=at'on pe sonnel can be davided into three G oups -'supe<~isors, con-'rol room staff and plant ecu'pmen" ppera~ors.
These exposures can be esti.
ted using radia ion zone 1.'mit values.
The values given in Tab3.e 12.4-1 show that the to al personae'ose for oper-ation ana shutaown is a proximately 22 man-rem or about 0.7 re./y" perpe"son.
As part o
this total the sure vxora, and cont ol room sta would be expec-ea to receive an exposure of less than 500 mrem~/yr if ~~hey remain in the cont=ol oom na ag~inistratjx.e o
'ce a eas.
These people wil~ I howeve spena time on
/'pection of p3.ar.t systems.
c.
Groun 3
2= the plant: heal a phys'cs/cnem's"~
personnel spent lt o= Meir t~e collect~G samples in Zone ZZi samp3.ing sta ions, they will recp've a maximum nose of 30) m=em/yr.
Assuming that they spend the remainder of their/time in Zone 2 and Zone ZZ Seas, thei=
totaii dose would be be'ween 1 ana
'2 rem per person.
The plant health physics/chemistry p//rsonnel also conduct ac't'n supreys and support maintenance activi 'es which recuire moni oring and pre-job raa'ation su eys.
The exposure to.the Seal+& physics/c emistry staff can range fram 1 4o.3; em/yr This is based on experience from operating pl ts.'
12.4-5
0
WhP <<2 Assum'ng a dose ate per person of 2 rem/yr and considering the 8 people in this group, he " tal personnel dose is 16 man-rem.
d.
G=ouo 4
The eng'nee ing staff and tec.ical supervisors will spend most of their ime 'n Zone areas where exposures will be le than
- 500, m em/yr.
They will spenc time i igher radia-
~'on areas.
However; the resu ing-dose that the wi'1 rece've 'is di cu to estimate accu tely.
The dose rece'd by the 9 people in this roup is taken 'e 4.5 man-em.
e.
G ouo 5 -
P
" sup visors will spend time supe v'sing Group an Group 3 personnel.
The'r dose rate would be a
ut he same" as that eceived by personnel in rou 1 and 3.
Th's value 's about 1 rem/yr.
~th 14 ople in this group, the total per nnel dose M 14 man-rem.
Gro n The adminis-'-at've and plan" pe sonnel w~ 1 spend "heir t'me in Zo e X radiat'on ar'eas.
T s, 's expected that th '" dose.rate will e less than 500 mrem/yr'.
Wit 11 peop'e in "'his
- group,
"'he -'tal personne'ose comes 5.5 man-rem.
The t al personnel dose o
211 groups is approx'.
ely 130 man em.
assuming tha anothe 130 man-rem wil'e ece'ved b
contractor personnel, as d'scussed
'n 12.4.2.2, to-'al pe sonne'xposure is estimated
-'o be 260 man-em.
.12. 4. 3 iNFD~TZON "XPOSURES Airbo ne radionuclioe concentrations
'n normally occup'ed a eas
- are, as discussed in 12.2.2, well below t.".e 1'mits set by 10 CFR Part 20 and hus inhalation exposures are negligible.
P h
P
\\"
s 12.4-6
~
I
12
~ 4.2.3 OCCUPANCY
- FACTORS, DOSE
- RATES, AND ESTIMATED PERSONNEL EXPOSURES A summary of the total estimated man-rem doses broken down by major function is given in Table 12.4-1.
More detailed breakdowns are presented in Tables 12.4-2 through 12.4-8 for each of the seven major functions qiven on Table 12.4-1.
These tables are based, on the more recent information obtained from References 4 through 7.
The data from Table 12.4-9 is given for comparison purposes only.
The results of the total estimated man-rem doses will be discussed with reference to six occupational groups as follows:
a.
Group 1 - This group includes maintenance personnel such as mechanical, electrical, instrument craftsmen and foremen.
There are approximately 46 people in this group.
Tables 12.4-4 and 12,4-8 provide the functional breakdown of exposure for this occupational group.
As can be seen from the Tables, 373 total man-rem may be expected.
Routine and special maintenance operations which include control rod drive repairs, Residual Heat Removal (RHR) repairs, snubber maintenance, etc.
account for approximately 62% o ihe average annual personnel dose.
One to three rem per year per person is projected for the station maintenance personnel for a maximum total of 138 man-rem per year.
Accordingly, the remaining 235 man-rem per year would be expected to,be received by nonstation maintenance personnel.
As discussed in 12.3. 1, the equipment layout and design and shielding design are such that the exposures are as low as reasonably achievable (ALARA).
b.
Group 2 - This group includes plant operations personnel composed of supervisors, control room staff and plant equipment operators.
There are approximately 29 people in this group.
Tables 12.4-2, 12.4-3, 12.4-5 and 12.4-6 show the total estimated man-rem for this group.
As can be seen, the total is approximately 111 man-rem per year or approximately 3.8 rem per year per man.
Personnel in this group will be performing routine and non-routine operation and surveillance, waste processing and refueling operations.
In plant operations personnel are expected to receive approx. one'o two rem per year per man for a maximum total of 58 man-rem per year.
The remaininq 51 man-rem per year may be expected to be received by nonstation personnnel.
As part of this total, the supervisors and control room staff are expected to receive an, exposure of.'less than 500 mrem/yr.."
c.
Group 3 - This group includes health physics/chemistry technician personnel.
There are approximately 8 people in this group.
If the plant health physics/chemistry personnel spend li,'f their time collecting samples in zone III sampling stations, they will receive a maximum dose of 300 mrem/yr.
Assuming the remainder of their time is spent in zone I and II areas the total dose is between 1
and 2 rem per person.
The plant health physics/chemistry personnel also conduct radiation surveys and support maintenance activities which require continuous and pre-job radiation surveys.
The exposure to these health physics/chemistry personnel ranges from 2 to 4 rem/yr.
This is based on experience from operating plants.
Assuming a dose of 3 rem per person per year and consi-dering 8 people in the group, the total is 24 man-rem per year.
Since this group covers vi rtually all functions delineated in Tables 2 through 8, this 24 man-rem is considered to be spread out across all the functions.
d.
Group 4 - This group includes engineers and technical supervisors.
There are approximately 9 people in this group.
Personnel in this group will spend most of their time in,Zohe I areas. where exposures are less than 500 mrem/yr.
Table 12.4-7 indicates approximately 129 man-rem per year will be experienced for inservice inspection.
Plant technical personnel will have a
supervising roll in this operation with nonstation personnel performing the inspecting operations, Thus, the projected dose estimate for the 9 people in this group is 4.5 man-rem per year, the balance being accounted for by the nonstation personnel.
e.
Group 5 - This group includes station supervisors such as health physics-chemistry supervisors, shift supervisors, etc.
There are approximately 14 people in this group.
Station personnel will supervise Group 1
and Group 2 personnel.
Their dose is approximately the same as personnel in these qroups.
With a projected dose estimate of 1
rem per year and 14 people in th group the total dose is 14 man-rem per year
~
- f. Group 6 - This group includes administrative and management personnel.
There are approximately ll people in this group.
Personnel in this group spend their time in Zone 1 radiation areas'he projected dose estimates will be less than 500 mrem/yr.
With ll people in this group and a
500 mrem per man per year the total dose is 5.5 man-rem per year.
As seen from Table 12.4-1, the total estimated man-rem exposure is 613 man-rem.
Groups 3, 5, and 6 are considered to,be spread oyer all the functions.
These'groups
.constitute only,7X of. the 'total exposore in -any.case..'. :
12.4.4 SiTE BOUNDARY DOSE Steam-handling ecuipment on the turbine operat'ng floor can contribute to the s'te boundary dose in two ways:
through a
direct component and through an air-scattered "skyshine" componen".
Since the N-16 bearing ecruipment is known, it can be shielded to reduce the direct component.
The "skysnine" component reaches the site boundary as a result of those gamma ravs which are directed such "hat thev bypass any inter-cepting shield walls and a
e scattered by the air to the site boundary.
The calculated results show that the skyshine dose will have i"s greatest effect on a dose point 1950 meters north of the turbine bu'lding.
The skyshine dose at this point will be approximately 3.6 mrem/yr.
Th's result-is based on a
plant capacity factor of 80%, at. full power operation.
The ma.'n con ributors to tnis dose and their con r'but'on (in percent) are the south moisture-separator reheater (NSR) which contribute 60%, the north MSR which cont ibutes 20%,
the c oss over 1'es'hich contribute 10%
and the tu bines and feedwater heaters which cont ibute 10%.
The dose es"ima"e was computed from a model ha-represents the N-16 gamma leakage by po'n isotonic sources.
This model uses the outpu rom the COHORT Code(>)
which g'ves the air-scat"e ed dose as a
unction o
distance anc source ray angle.
The site boundarv dose from 1'cuid and gaseous e fluen-s are discussed
'n 11.2.3 and 11.3.3.
12.4.5 RZ"ZR:"NCZS atomic Industrial Fo um, Compilation and Analysis of
$ 7 /
)
Da a
on Occupational Radiation =xoosure
=experienced at Ooeratina Nuclear Power Plants, September 974.
-H-.4 " USAEC, A Compilation of Occuoat'onal Radiation Exposure rrom Ln t Water Cooled Nuclear Power Plan 1969-1973, WASH-133.1.
Wells, J. B., Collins, D. G.,
and Neuendorf, W. P.,
Boundary Dose Rates Due to Gamma Ra s at Power t >8~3 Reacto S'es, Report R&-7202, Radiat'n Research Associates (November 12, 1972).
Vance J, Weaver C. L,, Lepper, E.
the Potential Impac on operating mRem Occupational Exposure Limit, D.
C. April 1978.
M.
A preliminary Assessment of Nuclear Power Plants of a
500 Atomic industrial Forum, Washington p+ ~5 Murphy, T..D.,
- Dayem, N. J., iland, 0. J.,
- Pasciah, W. J., Occupational Radiation Exposure at ligh. water cooled power reactor 1959-~975, VS.
- NRC, NUREG 0109, Washinoton D. C., Apl il 1976.
ted%.- {',
- Dickson, H. W., Cottrell, W.
D ~, Jacobs, D. C., Application of ALAD concept to exposure of workers at light water reactors, 2
RNC TYi-
- 5126, Oak Ridge Tennessee, November 1975.
t~R-7 I Ninth Annual Occupational Radiation Exposure
p
.'-0322, Washington.D.
C., October l977.
12.4-8
rAnLE 12.<-1 ESTIMATED ANNUAL DOSE TO PERSONNEL PLANT IN OPEBATION REACTOR BLDG.
TUBI3INH BLDG.
BADWASTE BLDG.
Personnel Grod Number o f People in Grou Occupancy Personnel Factor Dose
/
/
Occupancy Personnel Occupancy Personnel Fac tor Dose Factor Dose (hr/man/ r)
(man-rem)
(hr man r)(man-rem)
Maintenance
~Craftsmen
.-.(Group 1)
,Operators (Group.2)
I
-Technicians
- (Group 3)
- Engineers
.(Group.4)
Plant "Supe'rv'i sion
':(Group 5)
'Hanhgement
'(Group.6) 29 20 50 50 35 4.60 4.35 1.20
.22 1.46
.03 50 50 35 4.60 4.35 1.20
.22 1.46
.03 60 50 50 30
- 27. 60 7.25 2.00
.18 2.10
.05 11.86 39.18
Table 12.4-1
SUMMARY
OF OCCUPATIONAL DOSE ESTIMATES AT WNP-2
- 1. Routine Operation and Surveillance 2.
Non-Routine Operation and Surveillance
- 3. Routine Maintenance 4,
Waste Processing
- 5. Refueling
- 6. Inservice Inspection
- 7. Special Maintenance Total Man Rem/Year 38 15 275 47 129 98 613
~
e
> ~
f
4 OCC"~-'0"'L1 DOS"=:"S ""-'-S DUE"'" %0"
'. OP:":='.:OKS A:iD SURV:.:L ~iC:.
A'Z 'whiP-2 Ave.
Dose Ra te Re~/dw xposl're 3 'ber 0=
"'orkers
<<on Dose va~ 2o~/veer wa1.'.".g Check':g
.a 'ac Access Cha..ge Rooms Re'ay Room
"!Otor Geae=ator Se s
<<a te v Room Comov.te Roo-I
.5 l/shift 3./sh'it 2.2 5>> <<teal Ge-e a
jblJvol of(
A 9
Qn R '..o Ge...
SG:S
%11
~
V I
o Le 4
V ~Lp
~3Ci~ nea=
=xcha..gers RZCCi P".Os RRvvi
- x'Da.Ls:c..
7a.L}
- b. CRD P"-...Os v'Ta ts C"-. =
10
.5
.2 1/shi t
~ e:"e'.g 1ea CRD P='ters R iCv De mo Res:;.
Aa.Lks H ~ ~
S".~~ ~"mrs A
Coo e
s
'"S'acks CPS Storage c
Re@a'"
c.R'!v'CU Heat.x
~g
. =;.-.eat
=xc Ac=c ~'rp' changers ha~gers c
v.rv ='"..e 50 1/shlft 5.5
heck" ng (cont')
.De..i n ecoa t Tank
+ ecoat L>>P 4asi Sa a o
- -loo" D-a'n Sa-..p e
ROOK
- Ave, Dose Rate
-..Z2tl/r.~.
0.2,
- cposL' tie 0.5 i'm>.be=
0
"'o ke s
- "ec
~
~
~
~
1/shift Dose 0,1
'Paste SL"ge
>>]Lipe>>- 2 PQEp Vaste SL=ge 0+lr o S 'p
~
aQ I
~ ~
C S
~ 44>>
~ ~
C 2s 2
c
~
~ cg D's 0 \\ ~ %% Q p
l pv
~i'r Wp.s>> i:
L~P
~ c oo". D".a'n Co'lec-l'idP C1e '
was.
e
'znK 0.5 1/week 1.3 Soen=
B.csin P
...o Conce..sa e
. nzse Deca"."
Con='ensate Phase
~'"cga M'
'gy go ~
S>>.ic ge
-oc
'w'as t e "ZOO I
De
- ";cone" D
'1 <<e>>
>> c
~
e 1/week 0.8 V
~ 0
- ns=="-.eats
.5 1/shi t
& Cont o 'S Gen.
Co1 Units S
2 2
I 424 4l>>
Cva mal
- <<:cate"
=eec
=L'.ps D ~'pp>>
1 i e
~'s
& Vz ves Svsa e~
catch:."ez above De-.in
~anc.s
'ea'hShel 1 anl y Space'~CCw Heat mansion
x V
Ave.
Dose Roc
~We./2".
">:OOsl'- 2
- icle
~ ~ s
~
~woe>>
0=
'vo"ke" s w '>> Oil Dose ge Q/vep C'"e"k'"" (Co""t )
n
.3CC'.~
"=zca"..s on Taink 0.3 1/shiz t 1.6 D
~ ~
P ecc
.2...ks ni<< '-- o:l pip 2t lh aies
~
De='n.
P ecoa Pvwlps Sc..p
-'vs ac to
'ee>>
~p T" oh¹
':!TC 'i'oo'"
~ 4
~
~ ~ p v2
~
0 ls
+ ~ << 'li'ep>>
ric Va <<0 S
S V21ves
~~o."122 2>>
p c i 2 Tailks
~ I
~
Ot ~ wc
~
~ 1<< 7 S il
~
~
0.5 1/sh' t
- 13. 7 Cence-..se
'~ate" 3ox C'c.
~ ~
p>>l wc<<Sv c'ms
"-lveS React
". ":eec ps
~
nes D"-'ee
.H
~
~ c. cs
~ 'o S
- eec
'.late=
.-.ca=2"s Sea
'~i.k G 'in 0 <<ea..i
'LrOncens 2 Hain "u=oine B.ehea te" Sepaza"-o"-s Total 37.8
I
~
~
lg 7<$ 4 /> 0-3 DCC '.=ATTCN~
DG:-:-ST:."~T:-S BUR <iG;!D.'iROUT:i4:
OP:~~:TOih A.'iD SuRV:"iL c<<%C:-
AT VX~-2
~ \\
~ Ave, Bose Ra te mRe.-../'.":r.
- -:closure
<<ae
~ C~
ilrs.
iv,umber Of wo Ke s
":reo Dose
~'.an-Rem/vea=
1, 'Operation o-equipment:
- a. Traversing in-core Probe System 2
- b. Safety injection Sys 5
c.
"eedwater Pumps a
Turbine 1
- c. instrument Cal bra ion 2
2 1
1 1
3/year 1/month l/week 1/day 0.02 0.06 0.05
- 0. 73
- 2. Collect'n of Radioactive samples:
a.
iquid System b.
Gas System
- c. Solid System'.
Raciocnem'stry e.
3 adwa s te Operat'n Health Physics 10 5
10 1
5 0 '
0.5 0.5 1
8 1
1 1
2 3
2 1/day 1/mon th 4 /year 1/day 1/week 1/day Total
- l. 83 0.03 0.01 0
~ 73 3 ~ 75
- 7. 30 14.5
g al
7~5La (0 4-4 OCCU AT1OKA'OS~:S'-.'AT:"S DURING ROUTTbi': ".mZNT:-NANC~
AT )Pic?-2 Activitv Ave.
Dose Rate mRem/Hr.
".xposur e Time llrs.
Numb e"s Oc Uorkers P>>eo Dose an Rem/Yea>>
3.. >linor Repairs Reacto" Bu lding 2~ Ventilation
& Air Cond'ioning 3,'Contro1 Rod Dr've Re'p air*
- 4. Reactor Hater Clean'p Pump~
5, Reactor Vater Clean Up Valve
& Heat*
- 6. ".xchange
- 7. Resiauzl
- .Bat Re-oval System*
- 8. Sz=ety Re1ie< Valves
- 9. 8"in Steam "so3.at'on Vz1ves
- 10. Recirc.'Pumps 11 Sn bber nspector aeo 12 Y.isc..1'rb'ne bldg.
Repzi s
- 13. Reactor Peed Pumps
& Turbine 14.-Drain Coolers
'11>. S Bam wet A'r
- -jectors
- 16. 0='as System
- 17. ilTG Ac uator 18..Heater Dra'n "lash Tanks
- 19. Condenso" hater Box
- 20. Annua',1'urb'ne
':nspection 21 ~ cise
~
Radwzs te Pump Repairs
.22..Misc.
Radvaste VaLve
~ 'Repairs 23
~ P'1ter
& Demin.
24 Centerzuge g.5 15 18Q 110 200 80 lD 200 75 2
2 5
~ -5
.65 5
20 200 30 100 50 100 4Q 40 40 4Q
') Q 120 40
.4Q....
.30, 8
6 3
2 2
2 2
1 10 2
3 2
1/week 1/week 1/year 1/yea" 1/yez 1/ye-r 1/yezr 1/ve-r
/yearn 1/year 1/cay 6/ve"r 1/yezr
>/ye-"
6/ye-r 1/year 1/year 1/year 1/yezr 6/yez 6'/yezr 1/year
.'4/yezr 2.1 0.5, 18 19 30 43 12 45.
30 37
~ 3 5.8 p
96 (p.32 C,. 96
.24 g.08 p1 3.6 2.4
~
2.4.
'5.9
.32 1
7o
~ ~
~
~ ~
m pl~ zp. < - a C I ~<)-
ACtivitv
.-'.ve.
Dose
'Ra =e
-,.P,em/H r.
""xposur e
- ime
>>!1 S
~
<<)lusher pC
)>>>>0 ke s
ec
~
Dose
<<)fan-Rem/Year
<<fechanical (Cont.)
5.:-vaporation 6 ',Turbine ins tr.
E Control 7, Haste Solidi icat'on 8'rea <<fonitors 85 2
2 20 50 10 40 40 1
2 2
1/year 1/week 2/year 2/yea" 12.8
}.0 0>>32 O. 32 Total 274. 8
~ >>N
~
I L>>
~ Q ~
~ ~
~
>> ~ ~
~I
~ ~
~ )
~
I
~
I
~ J%
~
~ t 4
7pgfe /g,g g OCCUPAT'ZONAL DOSE ESTL'LCTES DURING 'WAS:E PROCESSING AT lVP-2 Activity Radwaste Control Room Ave.
Dose Ra te mRem/Hr.
.5 Exposure Time Hrs
~
Number Of Workers Prea.
1/shift Dose
?fan-Rem/Year 4r4 Sampling 6 P'lte C'hanging 10 1/week 2 ~ 1 Panel Operator Xnsp.
& "es-'ng 1/Q y
.73 Operat'o.. of Waste c
Packaging
<<ou>> p r 16
'/week Total 3 ~ 3 10r5
~ r
~'
r 1-79
pkIc. 12 4-'C 0 OCCUPAT. 'ONA DOS ":-ST'ET-DURTYG R" "UZ'AG A
4NP-2 Actl;vitv Ave. Dose Rate mRem/Hr.
Exposure
\\
~ 'me Hrs.
Yumber Oc Workers r reo.
Dose Han-Rem/Year Opening/Closing Reactor>>
Pressure Vessel 60 40 10 1/year
.. ".uel P"eparat'on
. Refueling
~: uei...":andi'ng
.:uel. S'pping 10 10 2
5 24 100
,100 100 15 1/year 1/year 1/year 1/year Total
- 0. 48 1.0 6.0 46,5 1-7o
OCCUPAT:GNAL DOS:":S:~~2'S DURING ZNS:"RV'XC" XXSP"=C ION AT Mi'P-2 Act'vitv Ave.
Dose Rate mRem/Hr.
"xpos-re Time Hrs.
Nv.u:her Oc Workers eo.
Dose Han-Rem/Year
. Removal/Replacement o'nsv.la"
'n 150 40 1/year
'. Zns "alla"'n/Removal
& Ladders 1/year
. inspecting Inside Drv Veil+
Recorder Data 150 50 80 80 1/year 1/year 72 5, inspecting Outside Dry Veil*
50 1/year Total 129 1-79
~ y I
7u'ate
/2-9 -Z OCCUPA 'ONA~
DOS ZSTZ".L~T:-S DURZNG SP - CZAt "L'sZha'T NAXC:-
AT 4NP-2 Activitv Sparger Replacement CRD Rep3.acement Ave.
Dose Rate r:Ben/sir.
lf 800 260 Exposure Time Hrs.
60 35 3umber OE 4orkers Prea.
Shoula not be necessary 1/yea" Dose Man-Rem/Ye 45.5.'urbine Ove haul 250 20 1/5 vea" Serv'ng Zn Detec"ors 15 50 1/year 2.3 0
Gas Cha"coz'ys.
Overhau'00 100 1/20 yezr Special Hzintenance Reactor 150 1/10 year 6
vlzter Clear 1lp Sys.
'<< I Risc. P'p'ng Repair s
To"a.l 80 100 5
1/yea.r 40-
~ 97. 8 1-79
1 l
WNP -2 TABLE PERSONN"L EXPOSURE FOR SEVERAL BWR PLAiNTS PLANT "3 RATED MWe:
640 PLANT CAL AG-YEAR (YRS)
TiDERMAL MWD DOWN HOURS REGULARS*
REGULARS TOTAL MAN-REM MAN-REM 73 5
452,708 2263 142 551 1449 72 4
540, 877
'548 108 71 3
486,380 1567 98 399 140 651 249 70 2
69 1
68 441,800 1687 49,806 67 48
.3
.3 P
ANT -,5 R TED MWe:
630 P~TNT CAL AG" THEROQ YEAR (YRS )
MWD DO'n'N P" GULARS*
R-GULARS TOTAL HOURS MAN-REM YAN-REM 73 4
457,173 72 3
417,'9 I
71 2
381,082 70 1
247,501 4487 69 2679 136 2678
,130 2798 68 31 0 594 106 206 62 218 305 Regulars
- Denotes the numine of Re<gular (Non-Contrac or)
Plant Employees
lO
~
~
I
TA3L" I.',. -":.- c (Conti nued )
P ANT
=..13 RA
=-D MWe; 652 Sheet 4
PLANT CAL AGE THERMAL DOWN REGULARS*
YEAR '(YRS )
MWD HOURS R" GU LARS" TOTAL MAN-RZM MAN-REM 73 3
/2 2
71 1
70 58I082 403,650 463,000 11,988 8040 3960 176 232 3240
- 244, 225 255 31 620 595 49 Regu ars:
- Deno" es "ne number of Regula.r Plant Employees (Non-Con" acto
)
t.
~>pi>>f l~~,~
-'?
{Continued)
Plant
=,';8 RATED. MNe:
Ul 200 U2,3 800 Sheet 2-PLANT CAL AGE THERMAL DONN REGULARS" YEAR (YRS)
MND HOURS REGULARS" TOTAL MAN-REM'MAN-REM (all units)(all uni s) 73 14 73 73 3
72 13 72 72 71 12 71 2
71 70 Vl 101, 353 Ul 681, 174 U3 495, 689 Ul 156, 783 U2 432, 725 U3 618, 888 Ul 99, 078 U2 364, 023 u3 149, 510 Ul 198, 835 2332 807 2577 17'2 6 3402 3140 2669 5944 498 239 225 202 576 368 3'5 127 909 728 7
143 69 10 Ul 120, 493 9
133,307 3292 3177
~
182
'18 9 215 303 67 8
115,362 3855 170 66 7
199 I 214 368 107'5 6
138,149 1800 103 64 5
138,688 l547 71 63,.'
3.30,,757 1992
-.,89..
Regulars - 'Denotes number oZ Regu'1 Plant Employees 363 128 90 ar '(Non-Contractor)
(~
gl al II f
,:.! >"~ t2,D-:.
(Continued)
PLANT ~8 RATED HWe:
Ul 200 (Continued)
U2,3 800 Sheet 3
P LANT CAL AGE THERMAL DOWN REGULARS*
YEAR (YRS )
MWD
. HOURS REGULA ARS* TOTAL
~N-REH HAN-REM (all units)(all units) 62 2
168,008 1716 182 86 145 6'
60 1
72,403 31,707 4500 105 105 64 (1)
PLANT I 9 -
PATED MWe
~ Ul '00 U2 800 PLANT CAL AGE TH"BMAL vEAR (vRS)
MWD DOWN REGULARS*
HOURS REGULARS
- TOTAL HAN-REH HAN-REH 73 2
Ul 646,112 970 73 1
Ul 676,909 1074 72 1
Ul 1',733 3502 72 U2 205, 080 PLANT
> 1 0 RATED HWe:
54 8 259 380 142 201 26 PLANT CAL AGE TH"RHAL vEAR
( YRS )
MWD DOWN R"GULARS*
HOURS R.GULARS* TOTAL HAN-REM HAN-R"M 73 3
72 2
71 445,000 1419 180,000 4367 83 82 4 05, 000 2131**
105 91 53 27 156 65 29
""Furst sax months only Regulars Denotes the number oZ Regular (Non-Contractor)
Plant Emoloyees
i ik