ACCELERATED DISTRIBUTION DEMONSTRATION SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9003160487 DOC.DATE: 90/03/02 NOTARIZED: JMi/+

DOCKET FACIL:50-397 WPPSS Nuclear Project, Unit 2, Washington Public Powe 05000397 AUTH.NAME AUTHOR AFFILIATION SORENSEN,G.C.

Washington Public Power Supply System RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Forwards supplementary info re 900224-application for amend to License NPF-21,revising Tech Spec 3.3.7.5.

DISTRIBUTION CODE:

A001D COPIES RECEIVED:LTR I ENCL

/

SIZE:

TITLE: OR Submittal:

General Distribution NOTES RECIPIENT ID CODE/NAME PD5 LA SAMWORTH,R INTERNAL: ACRS NRR/DOEA/OTSB11 NRR/DST/SELB 8D NRR/DST/SRXB 8E

-MB REG F

E 01 EXTERNAL: LPDR NSIC COPIES LTTR ENCL 1

1 5

5 6

6 1

1

.1 1

'1 1

1 0

1 1

1 1

1 1

RECIPIENT ID CODE/NAME PD5 PD NRR/DET/ECMB 9H NRR/DST 8E2 NRR/DST/SICB 7E NUDOCS-ABSTRACT OGC/HDS2 RES/DSIR/EIB NRC PDR COPIES LTTR ENCL

'1 1

1 1

1 1

1 1

1 1

1 0

1 1

1 1

NOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATEYOUR NAME FROM DISI'RIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 27 ENCL 25

C WASHINGTON PUBLIC POWER SUPPLY SYSTEM P.O. Box 968

~ 3000 George Washington Way

~ Richland, Washington 99352 March 2, 1990 G02-90-035 Docket No. 50-397 U.S. Nuclear Regulatory Commission Attn:

Document Control Desk Washington, D.C.

20555 Gentlemen:

Subject:

NUCLEAR PLANT NO. 2, OPERATING LICENSE NPF-21 RE(}UEST FOR AMENDMENT TO TECHNICAL SPECIFICATION 3.3.7.5 FOR SAFETY RELIEF VALVE POSITION INDICATION, SUPPLEMENTARY INFORMATION

Reference:

1)

Letter, G02-90-025, GC Sorensen (SS) to NRC, same subject, dated February 14, 1990 2)
Letter, G02-89-221, GC Sorensen (SS) to NRC, same subject, dated December 4,

1989 Reference

1) requested an emergency Technical Specification change as a result of two acoustic monitors; one being inoperable and the other exhibiting characteristics indicative of failure occurring soon.

The requested relief was to allow continuous operation until either the first outage of sufficient duration to effect repairs or the next scheduled refueling outage whichever occurred first.

Reference

2) requested a similar change but proposed that with adequate compensatory actions relief for failed SRV position indicator(s) could be allowed continuously without resorting to an emergency relief situation or plant shutdown.

The reference 2) request recognized

that, despite system improvement, the inherent sensitivity of the acoustic monitor device made future failures probable.

As a result reference

2) proposed that compensatory actions combined with alternate methods of determining position indication provided adequate justification for continued operation and emergency situations and/or unnecessary plant shutdowns, as directed by the present technical specifications, could be, avoided.

.,eL 9003ib04S7 90030Z PDR ADOCK 05000397 P

PDC

~ Page Two t

RE(VEST FOR AMEND. TO TS 3.3.7.5 FOR SAFETY RELIEF VALVE POSITION INDICATION, SUPPLEMENTARY INFORMATION In the reference

1) review of action statements addressing failed SRV position indicators it was recognized that Specification 3.4.2 also had action require-ments for failed acoustic monitors.

This was an oversight in the reference 2) submittal.

Accordingly, the purpose of this letter is to correct this oversight by requesting the attached page changes to Specification 3.4.2 also be considered within the scope of the reference

2) request.

Additionally, in reviewing the reference

2) proposed "Action 82 b." for Table 3.3.7.5-1 (two failed indicators on one or more SRVs) it was identified that restoration of one of the two failed indicators on each affected SRV would not allow an exit from Action 82 b.

Verbatim compliance with the proposed wording would require plant shutdown if the remaining indicator could not be restored.

The intent of the proposed change was that restoration of one of two failed indicators would allow exit from Action b.

and entry into Action a.

thereby avoiding an unnecessary plant shutdown.

Accordingly, the attached revised "Action 82" statement is submitted to replace that proposed by reference 2) and preserve the intent of the original submittal.

The Supply System has reviewed the attached changes with respect to the No Significant Hazards and Categorical Exclusion statements provided in reference 2).

With the intent remaining the same and the changes to specification 3.4.2 being similar to those requested in reference

2) the No Significant Hazards and Categorical Exclusion statements provided therein are appropriate for the attached changes.

This supplementary information has been reviewed and approved by the WNP-2 Plant Operations Committee (POC) and the Supply System Corporate Nuclear Safety Review Board (CNSRB).

Additionally, the State of Washington has been provided a copy of this letter.

Very truly yours, G.

C.

orensen, Hanager Regulatory Programs PLP/bk Attachments CC:

JB Hartin -

NRC RV NS Reynolds BCPKR RB Samworth NRC DL Williams - BPA/399 NRC Site Inspector

- 901A C Eschels EFSEC

STATE OF WASHINGTON)

COUNTY OF BENTON

)

Subject:

Re uest for Amendment to

. S. 3.3.7.5 for Safety Relief Valve Position Indication, Supplementary

Info, I,

G.

C.

Sorensen, being duly
sworn, subscribe to and say that I am the
Manager, Regulatory
Programs, for the WASHINGTON PUBLIC POWER SUPPLY
SYSTEM, the applicant herein; that I have full authority to execute this oath; that I

have reviewed the foregoing; and that to the best of my knowledge, information, and belief the statements made in it are true.

DATE ~ p/~k, 1990 G.

C.

So ensen, Nanager Regulatory Programs On this day personally appeared before me G.

C.

Sor ensen, to me known to be the individual who executed the foregoing instrument, and acknowledged that he signed the same as his free act and deed for the uses and purposes herein mentioned.

d 2 I~TI.I-

~ ))

o ary Pub sc a

nd or the STATE OF WASHINGTON Residing at Hy commission expires 7

14 91

0 I 1&

h~

- J

- r