gJ ACCELERATED I

UTION DEMONSI'WTION SYSIKlvf REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9005010197 DOC.DATE: 90/04/16 NOTARIZED:

NO FACIL:50-397 WPPSS Nuclear Project, Unit 2, Washington Public Powe AUTH.NAME AUTHOR AFFILIATION SORENSEN,G.C.

Washington Public Power Supply System RECIP.NAME RECIPIENT AFFILIATION FAULKENBERRY,B.

Region 5, Ofc of the Director

SUBJECT:

Forwards status rept for commitments made in 891130 ltr re commercial grade dedication process.

DISTRIBUTION CODE:

IE01D COPIES RECEIVED:LTR ENCL SIZE:

TITLE: General (50 Dkt).Insp Rept/Notice of Violation R sponse NOTES'OCKET 05000397 RECIPIENT ID CODE/NAME PD5 PD INTERNAL: ACRS AEOD/DEIIB DEDRO NRR/DLPQ/LPEB10 NRR/DREP/PEPB9D NRR/DST/DIR SE2 NUDOCS-ABSTRACT OGC/HDS2 RES/DSR/HFB/HFS EXTERNAL: LPDR NSIC COPIES LTTR ENCL 1

1 2

2

.1 1

1 1

1 1

1 1'

1 1

1 1

1 1

1 1

1

~

1 1

RECIPIENT ID CODE/NAME SAMWORTH,R AEOD AEOD/TPAD NRR SHANKMAN,S NRR/DOEA DIR 11 NRR/DRIS/DIR NRR/PMAS/ILRB12 OE DR EG F

02 FILE 01 NRC PDR COPIES LTTR ENCL 1

1 1,

1 1'

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 NOTE TO ALL"RIDS" RECIPIEWrS:

PLEASE HELP US TO REDUCE WASTEI CONI'ACI'HEDOCUMENI'ONIROLDESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATEYOUR NAMEFROM DISTRIBUTION LISTS FOR DOCUMENIS YOU DON'T NEEDt TOTAL NUMBER OF COPIES REQUIRED:

LTTR 24 ENCL 24

ai

='ASHINGTON PUBLIC POWER SUPPLY SYS'Fgg P.O. Box 968

~ 3000 George Washington Way

+ Richland, Washington 99352 30 APP20 A9; g2 April 16, 1990 Docket No. 50-397 G02-90-76 Mr. B.

H. Faulkenberry Deputy Regional Administrator U.

S. Nuclear Regulatory Commission Region V

1450 Maria Lane, Suite 210 Walnut Creek, CA 94596

Dear Mr. Faulkenberry:

Subject:

COMMERCIAL GRADE DEDICATION STATUS REPORT

Reference:

Letter, G02-89-217, G.O.

Bouchey to B.H.

Faul kenberry, NRC Inspection Report 89-21 Sample Plan Information, dated November 30, 1989.

The referenced letter provided additional information regarding the Supply System's commercial grade dedication process as a follow-up to a

November 20,

1989, management meeting.

In Attachment I to the referenced letter, we summarized the finding of our consultant "CYGNA Energy Services" and provided a

report by CYGNA discussing their review of 50 commercial grade items dedicated by the Supply System.

While CYGNA found the Supply System approach to dedication to be generally

sound, they did recommend that the Supply System perform additional work to bring documentation up to current guidelines.

In our November 30 letter, we pr ovided our estimated schedule for completion of this activity as well as other steps being taken by the Supply System to assure the adequacy of our commercial grade dedication process.

The attachment to this letter provides a

status report for those commitments made in the November 30 letter.

90t>5010197 900416 PDR

~OOCV 0&t..tO0=.W7 F'bc

Mr. B.

H. Faulkenberry Page 2

April 16, 1990 COMMERCIAL GRADE DEDICATION STATUS REPORT Ne have completed the resolution of the ten samples identified by the NRC and the fifty (50) samples identified by CYGNA.

He are nearing completion of an additional sample of commercial grade items in storage.

Based on the results of the samples examined by the

NRC, the samples reviewed by CYGNA, and additional samples reviewed by the Supply System we have demonstrated

,reasonable assurance that the inventory of commercial grade items is acceptable for use in safety-related applications.

Should you have any questions, please contact me.at (509) 372-5238 or Mr.

S.

H. 'Peck at (509) 377-2022.

Very truly yours, C

G.

C. Sorensen, Manager Regulatory Programs (MD 280)

GCS/tmd Attachment cc:

Mr. N. S. Reynolds,

Bishop, Cook, Purcell 8 Reynolds Mr. R.

B. Samworth, NRC NRC Document Control Desk Mr. D. L. Williams, BPA (399)

EVALUATION OF COMMERCIAL GRADE PROCUREMENT PROGRAMS Actions Original Estimated

~Con 1etion Status As Of 3/31/90 Future Procurements

1) Upgrade current process to enhance conformance to NCIG-07 guidelines
2) Independent gA/safety assessment of conformance with NCIG-07 1/90 12/89 See Note 1

Complete (Audit 89-503)

Past Procurements

1) Resolution of 10 i ssues identified by NRC
2) Develop and implement a "simplified review process" for selected stored items procured under past dedication processes in safety-related applications.

Use of or upgrading to NCIG-07 standards as part of the abbreviated review would not be required.

3) Review and resolution of the sample of 50 past procurements evaluated by the independent consultant (CYGNA)
4) Engineering review to determine if additional sampling is necessary 5)

As pari vl the NUI'NARC initiative to establish a dedication program to meet the criteria of NCIG-07, we will perform reviews of all reorders of items currently installed in the plant or in storage.

Accordingly, the results of past procurements will be reviewed over an extended period.

If any review identifies a mistake with past procurements; i.e.,

a hardware

problem, we will conduct appropriate generic reviews as necessary.

11/89*

12/89 3/90 12/89

~ t A V

Olif'VI Ilg Complete See Note 2

Complete Complete (See Note 3)

EVALUATION OF COMMERCIAL GRADE PROCUREMENT PROGRAMS (Continued)

Actions Original Estimated

~Com 1etioo Status As Of 3/31/90 Past Procurements

6) Complete additional sampling if needed (see item 4 above).
7) Reevaluate results of and need to continue the "simplified review process"

(""e item 2 abov").

6/90 6/90 Not Required (See Note 3)

On Schedule

  • Estimated completion date revised to March 1990 at November 1989 NRC/Supply System management meeting.

NOTES 1)

A new procedure PPM 1.17.2 "Spare Parts Engineering Review" was POC approved in December 1989.

This procedure, which is to replace the current PPM 1.3.39, will not be issued for implementation until other interfacihg procedures are also revised and approved.

This is expected to occur by June 30, 1990.

The Spare Parts Engineering organization is currently performing commercial grade procurement evaluations using PPM 1.3.39, as deviated May 1989.

With the procedure deviation to PPM 1.3.39, we meet the intent of NCIG-07 requirements.

However, since the responsibility for performing commercial grade dedications has been moved to Generation Enyineering, additional procedure developmeni; is required and is underway.

Procedure interpretation has been provided by guidance memoranda issued to the Spare Parts Engineering staff.

Training to the requirements of the deviated procedure and guidance memoranda, plus additional on-the-job

training, has been provided to those performing evaluations.
2) Assessment plan prepared in January 1990.

Implementation of the plan called for a random sample to review additional commercial grade material in storage for suitability of commercial grade dedication process.

This work is in process.

3) The engineering review concluded that additional sampling was not required from a statistical viewpoint.

0