GO2-99-067, Forwards Response to NRC 990211 RAI Re Util Request for Amend to Secondary Containment & SBGTS TS

From kanterella
(Redirected from ML17292B637)
Jump to navigation Jump to search
Forwards Response to NRC 990211 RAI Re Util Request for Amend to Secondary Containment & SBGTS TS
ML17292B637
Person / Time
Site: Columbia Energy Northwest icon.png
Issue date: 04/12/1999
From: Coleman D
WASHINGTON PUBLIC POWER SUPPLY SYSTEM
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
GO2-99-067, GO2-99-67, NUDOCS 9904210083
Download: ML17292B637 (15)


Text

REGULA Y INFORMATION DISTRIBUTION. SYSTEM (RIDS)

ACCESSION NBR:9904210083 DOC.DATE: 99/04/12 NOTARIZED: NO FACIL:50-397 WPPSS Nuclear Project, Unit 2, Washington Public Powe AUTH.K!AME AUTHOR AFFILIATION COLEMAN,D.W.

Washington Public Power Supply System RECIP.NAME RECIPIENT AFFILIATION Records Management Branch (Document Control Desk)

SUBJECT:

Forwards response to NRC 990211 RAI re util request Eor amend to secondary containment

& SBGTS TS.

DISTRIBUTION CODE: A001D COPIES RECEIVED:LTR ENCL SIZE:

TITLE: OR Submittal: General Distribution DOCKET 05000397 NOTES:

RECIPIENT ID CODE/NAME LPD4-2 LA CUSHING,J INTERNAL: ACRS NRR/DE/EEIB NRR/DE/EMEB NRR/DSSA/SRZB NUDOCS-ABSTRACT COPIES

'TTR ENCL 1

1 1

1 1

1 1

1 1

1 1

1 1

1 RECIPIENT ID CODE/NAME LPD4-2 PD LE CENTER

~D~MC NRR/DSSA/SPLB NRR/SPSB JUNG,I OGC/HDS3 COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

1 1

0 EXTERNAL: NOAC 1

1 NRC PDR 0

~qgig)(/id NOTE TO ALL "RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DZSTR1BUTZON LIST OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL DESK (DCD)

ON EXTENSION 415-2083 TOTAL NUMBER OF COPIES REQUIRED:

LTTR 15 ENCL 14

J '

April 12, 1999 GO2-99-067 WASHINGTON PUBLIC POWER SUPPLY SYSTEM P.O. Box 968

~ Richlatu/, Washhtgton 99352-0968 Docket No. 50-397 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Gentlemen:

Subject:

WNP-2, OPERATING LICENSE NPF-21 REQUEST FOR AMENDMENTTO SECONDARY CONTAINMENTAND STANDBY GAS TREATMENTSYSTEM TECHNICALSPECIFICATIONS (ADDITIONALINFORMATION)

Reference:

Letter, dated February 11,
1999, C Poslusny (NRC) to JV Parrish (SS),

"Request for Additional Information for the Washington Public Power Supply System (WPPSS) Nuclear Project No. 2 (WNP-2) (TAC NO. M96928)"

In the reference, the staff requested that additional information be provided to support review of our pending request for an amendment to secondary containment and standby gas treatment system Technical Specifications.

The additional information is included as an attachment.

Should you have any questions or desire additional information regarding this matter, please call me or PJ Inserra at (509) 377-4147.

Respectfully, DW Coleman Manager, Regulatory Affairs Mail Drop PE20 Attachment cc:

EW Merschoff - NRC RIV JS Cushing - NRR NRC Sr. Resident Inspector - 927N DLWilliams - BPA/1399 PD Robinson - Winston &Strawn 990eas0083 9eoaaa PDR ADOCK 05000397

'I P

PDR

-"00000

REQUEST FOR Ai~(~NTTO SECONDARY CONTAIENT AND STANDBYGAS TREATMENTSYSTEM TECHNICALSPECIFICATIONS (ADDITIONALINFORMATION)

Attachment Page 1 of $0 Question 1:

A loss of offsite power (LOOP) has been assumed for the selected analyses.

The conservatism of this assumption should be justifie since the normal heat load would be much higher than the loads considered under LOOP conditions.

Without such supporting justification, a case including offsite power should be added to the case matrix.

~Res ense:

WNP-2 assumed the LOOP loss-of-coolant accident (LOCA) as the analyzed event, which includes a failure of emergency diesel generator E-DG-1 and loss of power to all of Division 1 (most severe single failure) coincident with the LOCA in primary containment.

The reactor building normal heat load was determined by monitoring the flow and temperature rise of the reactor exhaust air/reactor outside air normal ventilation system over a 24-hour period, and averaging the results to obtain a value heat load in Btu per minute.

The normal heat load is assumed to be split equally across the reactor building floors, and that this load will drop linearly to zero after one hour into the accident.

Standard Review Plan (SRP) Section 6.2.3 states that in meeting the requirements of General Design Criterion 16 regarding functional capability of the secondary containment, the analysis of the pressure and temperature response of the secondary containment to a LOCA occurring in the primary containment should be based on the assumption of LOOP and the most severe single active failure in the emergency power system.

Since a LOOP is assumed coincident with the LOCA, all the emergency room coolers will be powered by diesel generators.

One electrical division is assumed to be lost, resulting in the loss of some room coolers, a train of the standby gas treatment

system, and a

loop of standby service water.

However, the drawdown analysis assumes that the heat loads remain when the electrical division is lost.

The room cooler performance data assumes that the room coolers operate with a 65% cooling coil efficienc (i.e., a measure of cooling coil fouling).

That efficienc was lowered to 50%

for the most limiting drawdown analysis.

The analyses

are, therefore, justifie by the inclusion of both the most conservative heat load (normal and emergency) as well as the most conservative power conditions (LOOP/LOCA) and the loss of the most limiting service water division.

In addition, room cooler efficienc was lowered to 50% for the most limiting drawdown analysis.

REQUEST FOR AMEIdENT TO SECONDARY CONTAvIENT AND STANDBY GAS TREATiiIENTSYSTEM TECHNICALSPECIFICATIONS (ADDITIONALINFORMATION)

Attachment Page 2 of 10 Question 2:

Many of the files refer to GOTHIC as a best estimate code.

Since the analyses represent design basis accident (DBA) conditions, provide a discussion of the safety margins that are available to change the best estimate results to conservative results.

~Res ense:

The following is a list of conservatisms incorporated into the GOTHIC models:

1.

There is a conservative assumption in the drawdown analysis of a 20-minute

delay, allowing unfiltered release from secondary containment (reactor building) to bound the offsite dose (no filtration credit is taken until the building is negative 0.25-inch w.g.).

The most limiting calculated drawdown is less than 12 minutes.

2.

No credit is taken for leakage out of secondary containment during the time that building pressure is positive.

The outside atmosphere leakage into secondary containment is modeled using boundary conditions and flow paths that are sized to give 2240 cfm inleakage at standard temperature and pressure.

The measured plant leakage has been less than 1,000 cfm since the 1990 time-frame when we began to record surveillance data.

3.

Actual meteorological data was used.

This is conservatively realistic since more accurate data is incorporated as a r'esult of actual weather information collected over a longer period of time (six-year span from January 1, 1984, to January

1. 1990) than the original licensing analysis.

4.

Containment peak pressure is assumed constant at P,.

Conservatively bounding, the pressure condition is assumed to peak at time zero and results in a constant high leak rate for the 30-day period.

5.

For the most limiting (winter) case, leakage is assumed to be 60% at ground level and 40% at roof level.

This places the potential for leakage in the location that results in the longest drawdown time for the winter meteorological conditions.

REQUEST I'OR AME!CENT TO SECONDARY CONTAILIENTAND STANDBYGAS TREATMEiVZSYSTEM TECHNICALSPECIFICATIONS (ADDITIONALINFORMATION)

Attachment Page 3 of '10 6.

The model conservatively assumes atmospheric pressure at an elevation consistent with maximum inleakage conditions.

Atmospheric pressure was defined at the 444-foot elevation for winter conditions and at the 606-foot elevation for summer conditions.

This assumption results in conservative drawdown times.

7.

The design basis for room cooler efficiency is 65%; however, it is assumed in the most limiting drawdown analysis that the room coolers operate with a 50% cooling coil efficiency.

8.

One electrical division is assumed to be lost, resulting in the loss of some room coolers, one train of standby gas treatment and one loop of standby service water.

However, the heat loads are assumed to remain when the division is lost.

9.

Standby service water is available at 2.17 minutes (130.2 seconds) into the transient following a LOOP.

The high pressure core spray system is actually available at 1.00 minute but is modeled to come on at 2.17 minutes.

10. The decay heat load for the spent fuel pool is conservatively assumed constant for six months.

11.

Non-adiabatic boundary conditions were conservatively assumed for the surface of the secondary containment structure exposed to the outside environment for summer cases.

Adiabatic heat transfer was used for the winter cases.

This results in the most conservative drawdown times.

Question 3:

Material provided on the docket indicates the inleakage rate is established based on a linear relationship with pressure.

This is the most conservative approach.

However, the t>les show leakage based on a best lit of the data taken from secondary containment tests.

This data shows that the actual leakage response is somewhere between linear and the square root of pressure.

Verify that the linear relationship has been used for the reanalysis.

REQUEST FOR AivlZIIENT TO SECONDARY CONTAIIsIENTAND STANDBY GAS TREATMENTSYSTEM TECHNICALSPECIFICATIONS (ADDITIONALINFORMATION)

'ttachment Page 4 ot 10

~Res onse:

The best-flt leakage relationship used a nonlinear equation to establish the plant leakage surveillance test acceptance criteria, rather than provide input to the secondary containment analysis models.

The differential pressure associated with standby gas treatment system flow rate is a combination of linear and quadratic effects due to leakage through seams in the secondary containment superstructure and through doorways.

In contrast, the building drawdown analysis does not accept any input as a function of variable pressure, and there is no equation installed in the model to drive the boundary condition.

Instead, a

constant peak containment pressure is used to maximize the analyzed radiological release.

Question 4:

The docketed material indicates that a primary to secondary leakage rate of 0.5%/day has been included in the analysis.

However, within the tiles there is evidence that this leakage has been neglected.

Indicate what was assumed.

If neglected, show why it will not impact the results.

~Res onse:

The maximum allowable leakage from primary to secondary containment is 0.5wt%/day, which is: approximately 4scfm at P,.

This is considered negligible compared to standby gas treatment system flow of 5000 cfm when used for the drawdown analysis.

However, this leakage is accounted for in the radiological analysis.

Question 5:

The reanalysis assumes that the initial pressure is at zero gauge.

The current analysis assumed an initial pressure of a negative 0.25 inch w.g. Therefore, the technical speciflications (TSs) contain daily surveillance of secondary containment pressure.

The proposal deletes all pressure surveillance.

However.

there remains a need to assure that positive pressure is never achieved.

Under the proposed deletions it is unclear as to how assurance can be provided that positive pressures are never reached.

Address how this condition would become known without any pressure surveillance.

~Res onse:

Pressure surveillances are performed in accordance with Operations procedures for shift and daily instrument checks during Modes 1 through 5, as applicable.

The FSAR will also describe that secondary containment is normally maintained at a negative pressure, and any additional changes to the FSAR related to this design will be controlled pursuant to the provisions of 10 CFR 50.59.

These surveillances will continue to be performed to comply with the FSAR.

REQUEST FOR AMEI\\QIEiVfTO SECONDARY CONTAIIIENT AND

~

STANDBYGAS TREATMENTSYSTEM TECHNICALSPECIFICATIONS (ADDITIONALINFORMATION)

Attachment Pag& 5 of 10 Question 6:

Although the TSs are being changed, the Final Safety Analysis Report (FSAR) will not be changed as part of this request.

For consistency, the FSAR should be also modified along with the TSs.

Cont>rm that this will be the approach.

~Res onse:

In accordance with plant procedures, and pursuant to 10 CFR 50.71(e),

the FSAR will be revised accordingly pending approval of this Technical Specil)cation amendment request.

Question 7:

It is indicated that the standby gas treatment (SGT) system will not be initiated until 2 minutes after the loss of coolant accident (LOCA).

Describe why it is taking so long to start the SGT.

~Res onse:

Standard Review Plan Section 6.2.3 states that any delay due to system design in actuating the secondary containment depressurization and f>ltration system should be considered.

The timeline for the start of a standby gas treatment system lead and lag fan following an accident signal is shown as follows:

DGIrated Conditions Lead Htr S:arts Lead Fan Starts OFull Speed Lead Fan/Hu Trip (Lead Fan Low Flow SGT-FS 1A1)

Time (sec) 0 DG Start and Load 15 ECCS Pmpa Stan E-RLY-3TR/7 HTR Pre Heat 0-.10 SGT-RLY-1TR/A1 SGT-RLY-2TR/Al 5-20 120 Limit 105 110 30---

50 SGT.RLY-1TR/A2 0

10

-4GT.RLY.TYJ2A2-SGT SGT Lag Start Htr Starts (Lead Fan LowAP SGT-FIS 2A2)

Lag Fan IFull Speed The timeline shows 15 seconds for an FAZ signal to diesel generator start and load; 30 seconds for sequencing on of the lead standby gas treatment system heater; 10 seconds for heater warm up; 20 seconds for failure of lead fan to develop a minimum tlow rate; and 10 seconds for the lag heater to start and warm up, at which time the lag fan would start.

REQUEST FOR AMERIEsVf TO SECONDARY CONTACLENTAND STANDBY GAS TREATiiIENTSYSTEM TECHNICALSPECIFICATIONS (ADDITIONALINFORMATION)

Attachment Page 6 of 10 Question 8:

Figure 3: WNP-2 Design Basis Meteorology states:

"Meteorology Enveloped by this Curve ) 95%."

The lower starting point of the curve reflects 0 wind speed and O'.

Please discuss the source of this curve and why the assumptions are conservative.

~Res ense:

The weather conditions outside the reactor building influence the drawdown analysis by means of heat transfer to the standby service water spray ponds and through the reactor building exterior walls (summer case only).

The outside weather conditions also influence the outside pressure distribution (i.e.,

boundary conditions are impacted) and building inleakage.

It was determined that selecting 95 percent of the WNP-2 site-specifi data was sufficient to characterize the reactor building drawdown response following a design basis accident, based on guidance contained in Regulatory Guide 1.145 and discussions with the NRC reviewers.

The site specific meteorological data consisted of pressure, temperature, wind speed and relative humidity measurements.

The WNP-2 site-specific meteorological data were used for a six-year span from January 1, 1984, to January 1, 1990.

The actual data used to evaluate the 95% wind and temperature envelope, as the design basis meteorology for the secondary containment, is shown in Table 1.

The data includes the incidence (in hours) of particular weather conditions of temperature and wind speed in the six year time span.

A corresponding calculation was performed and the Table 1

curve was generated which encompasses a minimum of 96.1% of all WNP-2 weather conditions, and excludes approximately four percent as a

conservative approximation of 95%/5%.

The percent of weather conditions excluded is summed across the bottom of the table.

The shaded blocks on Table 1

indicate the winter and summer cases analyzed in the calculation.

The temperature and wind conditions were determined so that the drawdown times would essentially be equal or bounded by the case with no wind for both the summer and winter cases (i.e., the winter cases have approximately equal drawdown times and the summer cases have approximately equal drawdown times).

REQUEST FOR AlVIEIENT TO SECONDARY CONTAvtENT AND STANDBYGAS TREATMENTSYSTEM TECHNICALSPECIFICATIONS (ADDITIONALINFORMATION)

Attachment Page 7 of 10 For ease of reference, the following table shows the drawdown times for the shaded areas on Table 1.

Cases one through four are winter conditions and cases five through seven are summer cases.

The drawdown times were based on 65%

room cooler efficiency and 75'F standby service water system temperature.

Case Tem erature ('F) 18 52 74 88 94 Wind Speed (mph) 13 17 17 Drawdown Time (sec) 632 628 625 625 484 508 525 For the various atmospheric conditions considered, the winter cases yielded longer drawdown times than the summer cases.

The limiting case is when the atmospheric temperature is O'F with no wind, with a standby service water system spray pond temperature of 75'F, Division 2 electrical power (i.e.,

Division 1 fails),

and one train ot'he standby gas treatment system in operation.

The drawdown time for this case is 632 seconds (10.53 minutes).

Zero wind speed and zero degrees temperature was used because the temperature effect on the differential pressure is the prominent factor, due to the higher differential temperature between the inside and outside temperatures.

The'most limiting drawdown analysis presented in our submittal is based on a more conservative assumption of 50% room cooler efficiency (versus 65%)

and a standby service water system temperature of 77'F (versus 75'F).'his resulted in a more conservative drawdown time of 711 seconds (11.85 minutes), but had no impact on the Table 1 curve.

Letter GO2-96-199, dated October 15, 1996, PR Benus (SS) to NRC, "Request for Amendrnetn to Secondary Contaiiunent and Standby Gas Treatment Systetn Technical Specitications"

REQUEST FOR ANIEIIENT TO SECONDARY CONTAOIENTAND STANDBYGAS TRE<ATMENTSYSTEsM TECHNICALSPEsCIFICATIONS (ADDITIONALREFORMATION)

Attachment Page 8 of 10 The effects of wind dispersal for offsite dose calculation are also accounted for in the derivation of X/Q as was discussed in our December 1997 follow-up 2

letter.

In the calm, stable conditions, the release rises to a limited height and stratiftes, spreading over an increased

area, and causes the highest ground concentrations, versus higher wind velocities which support faster dispersal of a release.

Question 9:

It has been indicated that the GOTHIC code has been validated by comparing results of a

high energy line break (HELB) event in the secondary containment with results using RELAP.

This is not appropriate since the event is not applicable to the secondary containment response without a high energy line break.

The validation needs to compare results to similar conditions.

For example, data taken during normal ventilation system operation could be used to compare with a GOTHIC analysis.

Therefore, an acceptable method of validation should be provided for this application of the GOTHIC code.

~Res oose:

It was necessary to perform a benchmark of the GOTHIC code speciftc to the low flow/natural circulation conditions present in secondary containment under the building conditions prior to a LOCA.

The benchmarking effort is discussed as follows:

1.

A model of secondary containment using the HELB model from the GOTHIC benchmark analysis discussed in Attachment 5 of our original submittal was utilized to analyze the "no leak" condition.

The leaks were removed, the standby gas treatment system turned off to simulate normal conditions, and normal ventilation was added.

The model was reviewed for stability and ability to simulate plant conditions and no stability problems were noted.

2.

A model of secondary containment using the secondary containment long-term drawdown model discussed in our original submittal was utilized to analyze the no leak/natural circulation condition.

The containment leakage was removed.

the standby gas treatment system turned off, and normal ventilation added.

The model was reviewed for stability and ability to simulate plant conditions and the results proved the model is stable under normal heat load conditions.

Letter GO2-97-218, dated Decetnber 4. 1997, DW Coleman (SS) to NRC. "Request for Amendmern to Secondary Containment and Standby Gas Treatment System Technical Specittcations (Additional Inforntation)"

REQUEST FOR AMEi~NTTO SECONDARY CONTA&fENTAND STANDBY GAS TREATMENTSYSTEM TECHNICALSPECIFlCATIONS (ADDITIONALINFORMATION)

Attachment Page 9 of'10 3.

The drawdown model in item 2 above was modified to use outside weather data for input to the boundary condition for building leakage, and secondary containment initial conditions were set to agree with plant,

. data.

Building auxiliary heating was used to maintain room temperatures.

The results of this benchmark model were compared to plant temperature data.

The results of the benchmark analysis show close agreement with plant data and most of the data points were within 5'F of the calculated values.

At least one node was needed per floor to approximate the natural recirculation conditions and yield accurate temperature

profiles, and greater accuracy was obtained by subdividing the floor nodes based on plant air flow restrictions.

The temperature predictions for the higher elevations (i.e., 548-foot and 572-foot) were slightly above plant data and the predictions for the 522-foot elevation were slightly lower.

These are reasonable results for the temperature profiles.

The flow velocities for two floors were also examined and found to be under 5 ft/sec, which demonstrates consistent flow stability for the solutions.

In summary, the results of these three analyses demonstrate that GOTHIC reliably performs low flow condition calculations and that the secondary containment models used are adequate for the task of simulating reactor building conditions.

REQUEST FOR AMENDENT TO SECONDARY CONTAIENT AND STANDBY GAS TREATMENTSYSTEM TECHNICALSPECIFICATIONS (ADDITIONALINFORMATION)

Attachment Page 10 of 10 Table 1. Surnntary of WNP-2 Meteorological Data KVindSpeed (mph)

TCTIIp (CPJ

~ 15

~ 10 OI 13 20 13 10 911 II 17 13 15 15 17

)17

8'.<<.".c;.0 I 15 16 24 IO IZ 14 16 10 15 12 13 28 28 51 IS 19 29 21 10 15 10 IS 17 159 116 40 J::::r."V:0 18':

24 26 52 74 76 45 57 53 61 71 19 28 12 348N< 6 311 423 575 527 532 515 529 511 471 293 174 IIO SI 17 17 171 175 319 439 471 423 446 442 393 272

'73 218 IOS 19 51 IOI 142 161 113 192 181 234 30 1 Z63 317 351 289 "81 230 230 175 175 159 IJ6 141 17 17 17 47 42 132 159 181 169 216 199 ISJ 168 2 IO 169 130 121 123 SAN".4 (54 43 22 17 15 IO 14 16 15 21 21 114 128 143 136 100 IZ5 I IS II3 52 47 42 19 19

~:I ( $<<I34 21 51 74 59 59 52 29 24 13 15 14 17 15 19 47 42 27 41 49 17 19 12 17

'. )86888 26,'9 IS 18 31 23 19 13 10 IO 21 21 19 23 13 13 14 10 IOZ 104 106 108 IIO 112 114 116 I IS I"0 0.0672<<0.425'.479' 0.4819'.4207'.3578

~

0.3122'.28 194

0. 368&

3.

9'Percent excluded er willd 8

,0 A

N A