'o t

s-GPU Nuclear Corporation b Nuclear =ingeBs48o S Middletown. Pennsylvania 17057 717 944-7621 TELEX 84-2386 Writer"s Direct Dial Number:

April 20, 1983 5211-83-122 Office of Nuclear Reactor Regulations Attn: John F. Stolz, Chief Operating Reactors Branch No. 4 U. S. Nuclear Regulatory Commission Washington, D.C. 20555

Dear Sir:

Three Mile Island Nuclear Station, Unit 1 (TMI-1)

Operating License No. DPR-50 Docket No. 50-289 TMI-l Steam Generator Repair Report (GPUN-TDR-007 Rev. 1/BAW 1760 Rev.1)

Enclosed for use in your review of the TMI-l Steam Generator Repair is Revision 1 of the "Once through Steam Generator Repair Kinetic Expansion Technical Report." Revision 0 of this report dated November 1982 was sent to you by letter dated January 20, 1983 (5231-83-020).

Some of the information in this submittal is considered proprietary to B&W and their subcontractor Foster Wheeler Energy Applications, Inc.,

as sworn by J. H. Tayler, Manager, B&W Licensing, in his affidavit presented with Revision 0. Pages, paragraphs, tables and figures con-taining such information have been marked " proprietary" in the text of the document. Cross-references showing the relocation of proprietary material in Revision 1 from that shown in Exhibit B of the Affidavit for Revision 0 is attached. It is requested that this information be protected from public disclosure under the provisions of 10 CFR 2.790(b).

Sincerely, f f Lukill Director, TMI-l l

Enclosures cc: J. Van Vliet O hh9 PDR GPU Nuclear Corporation is a subsidiary of the General Public Utilities Corporation