Line 3: Line 3:
| issue date = 08/16/1991
| issue date = 08/16/1991
| title = Part 21 Rept Re Potential Generic Component Defect Found During Insp of Asea/Abb Type RXMH2,Model RK223068-EA & RK223069-EA Relays.Caused by Misplacement of Insulating Tape Installed on Coil Termination
| title = Part 21 Rept Re Potential Generic Component Defect Found During Insp of Asea/Abb Type RXMH2,Model RK223068-EA & RK223069-EA Relays.Caused by Misplacement of Insulating Tape Installed on Coil Termination
| author name = JANS D L, WALLACE W H
| author name = Jans D, Wallace W
| author affiliation = ABB COMBUSTION ENGINEERING NUCLEAR FUEL (FORMERLY
| author affiliation = ABB COMBUSTION ENGINEERING NUCLEAR FUEL (FORMERLY
| addressee name =  
| addressee name =  

Revision as of 10:18, 18 June 2019

Part 21 Rept Re Potential Generic Component Defect Found During Insp of Asea/Abb Type RXMH2,Model RK223068-EA & RK223069-EA Relays.Caused by Misplacement of Insulating Tape Installed on Coil Termination
ML17348B043
Person / Time
Site: Turkey Point  NextEra Energy icon.png
Issue date: 08/16/1991
From: Jans D, Wallace W
ABB COMBUSTION ENGINEERING NUCLEAR FUEL (FORMERLY
To:
Office of Nuclear Reactor Regulation
References
REF-PT21-91 NUDOCS 9108220098
Download: ML17348B043 (6)


Text

ACCELERATED STIUBUTION DEMON POTION SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)ACCESSION NBR:9108220098 DOC.DATE: 91/08/16 NOTARIZED:

NO DOCKET g FACIL:50-250 Turkey Point Plant, Unit 3, Florida Power and Light C 05000250 50-251 Turkey Point, Plant, Unit 4, Florida Power and Light C 05000251 AUTH.NAME AUTHOR AFFILIATION WALLACE,W.H.

Combustion Engineering, Inc.JANS,D.L., Combustion Engineering, Inc.RECIP.NAME

-RECIPIENT AFFILIATION NRC-No Detailed Affiliation Given

SUBJECT:

Discusses 910812 notification of potential generic component defect found during insp of ASEA/ABB type RXMH2,model RK223068-EA S RK223069-EA relays at facility.DISTRIBUTION CODE: IE19D COPIES RECEIVED:LTR

(.ENCL G SIZE: TITLE: Part 21 Rept (50 DKT)NOTES D RECIPIENT ID CODE/NAME PD2-2 LA AULUCK,R INTERNAL: AEOD/DSP/ROAB NRR DO OGCB11 G FILE 01 RGN3 RGN5 EXTERNAL: INPO RECORD CTR NSIC SILVER,E COPIES LTTR ENCL RECIPIENT ID CODE/NAME PD2-2 PD AEOD/DS P/TPAB NRR/DRIS/RVIB9D RES/DSIR/EIB RGN2 RGN4 NRC PDR COPIES LTTR ENCL D D D D NOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE!CONTACT THE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT.20079)TO ELIMINATE YOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!TOTAL NUMBER OF COPIES REQUIRED: LTTR 18 ENCL

ilk ODOD liQODOD ASEA BROWN BOVERI August 16, 1991 Director, Office of Nuclear Reactor Regulation US Nuclear Regulatory Commission Washington, D.C.20555

Subject:

Notification of Potential Generic Defect Per 10CFR Part 21 Notification By: ABB Power T&D Company Inc., Relay Divisions 4300 Coral Ridge Drive Coral Springs, FL 33065 William H.Wallace Manager Total Quality&Process Technology (305)752-6700 On August 12, 1991, United Controls Division of HUB Inc.submitted notification to the Director, Office of Nuclear Reactor Regulation of a potential generic component defect found during an inspection of ASEA/ABB Type RXMH2, Model RK223068-EA and RK223069-EA relays at Florida Power and Light's Turkey Point Units 3 and 4.ABB Power T&D Company, Inc.has marketing responsibility for this product in the United States.The product is manufactured in Sweden by an affiliate.

ABB Power T&D Company Inc.also has responsibility for notifications, customer contacts and similar items, and it is in this capacity that this notification is made.Additional investigation has confirmed that all type RXMH2 AC or DC voltage operated heavy duty auxiliary relays manufactured from March, 1989 until September, 1990, have the potential for coil insulation breakdown.

This coil configuration is unique to the type RXMH2 relay.Investigation of sales records indicates that the type RXMH2 relay has been sold as a commercial grade component for protection and control systems to a wide variety to customers.

Many of the RXMH2 relays are sold to original equipment manufacturers for incorporation into systems purchased by utility end users.Relay customers are being notified through the following message sent August 15, 1991, to all ABB Power T&D Field Sales offices for transmittal to original equipment manufacturers who may have purchased RXMH2 relays and to utility customers who may have these relays installed in nuclear facilities.

ABB Power T&D Company Incr Relay Division 91BW160 9i08220098 9108i6 PDR'DOCK 05000250 I PDR 4300 Coral Ridge Drive Coral Springs, FL 33065 Telephone:

(305)752-6700 Telefax: (305)345-5329~El<ito

c~August, 16, 1991 Page Two'>>ABB was recently notified of the failure of a type RXMH2 heavy duty auxiliary relay.The RXMH2 AC or DC voltage operated auxiliary relay is especially suited for protective relaying and industrial applications requiring electrically independent multiple contacts with high breaking capacity and are often applied in parallel with fast operating trip relays.Examination of the failed'elay revealed'nsulation breakdown at the coil termination.

This mode of failure will cause the relay to fail to'operate under fault conditions.

This problem is caused by the misplacement of insulating tape installed on the coil termination during assembly of the product.Examination of additional RXMH2 units at the same customer installation indicates that this condition may occur on other RXMH2 units.Further investigation has shown that this deviation in assembly procedure may have occurred in units manufactured from March, 1989 until September, 1990.Each rel'ay is marked in the upper right corner of the legend plate with the year and week of manufacture (e.g.9036).The relays that may have this problem are the type RXMH2 marked 8909 up to and including 9036.Field data does not indicate a reliability problem with this component.

However, ABB is aware of application of the RXMH2 auxiliary relays in protection and control systems of U.S.nuclear installations.

RXMH2 relays in applications where a failure to operate could cause a substantial safety hazard should be checked for coil insulation integrity.

Please contact your local ABB Field Sales office or John Wilson (305-752-6700) at the Coral Springs Relay Division Total Quality Department for further information." Prepared By: William H.allace Manager Total Quality&Proce Technology Reviewed By: onald L.Jans Vice President&General Manager Date: WHW/lw Michael Charlton/United Controls S.Franzone/FP&L 91BW160