ML20135E227

From kanterella
Jump to navigation Jump to search
Part 21 & Deficiency Rept Re Potential Problems W/Natl Valve & Mfg Co Pipe Clamps.Initially Reported on 850613.Ltrs Sent to Purchasers of Pipe Clamps Encl for Perusal
ML20135E227
Person / Time
Site: Hatch, Palo Verde, Perry, Saint Lucie, Turkey Point, San Onofre, 05000000
Issue date: 08/23/1985
From: Thomsen E
PACIFIC SCIENTIFIC
To: Thomas Young
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
REF-PT21-85, REF-PT21-85-401-000 6000-QS-185-85, PT21-85-401, PT21-85-401-000, NUDOCS 8509160331
Download: ML20135E227 (17)


Text

-

('

Kin Tech Division .

t Pa CIFIC SCIENTIFIC y August 23, 1985 6000-OS-185-85 US NPC 1450 Maria Lane Suite 210 Walnut Creek, California 94596 Attn: Mr. Tolbert Young

Dear Mr. Young:

In fol1Jw-up to the notification of a potential CFR21 probicm, discussed with you on 6-13-85, and the written notification sent to you on 6-18-85 as required by 10 CFR 21 para. 21.21(b) (3), the attached data is sutmittal for your perusal.

These letters were sent to the various firms who purchased the subject pipe clamps frm PSCo. The letters are self explanatory and ccmplete the action by PSCo unless we are notified to the cm-trary by you or the custmer.

If you should require any additional information please contact the undersigned or Mr. Paul lladnagy, Director of Technical Operations at (714) 774-5217.

Very truly yours, PACIFIC SCIHfrIFIC Kin-Tech Division E. R. Thmsen tunager Quality Systm s & Services ERT/ran CC: P. !!adnagy t. NGEe Attachments (8) -

6i I Ed b2 ilr,gg ,

8509160331 850823 #

1g fd hDR ADOCK 0 % 2 6 03Al331 1346 S. State College Boulevard, Anaheim, Callfornia 92803 (714) 774 5217, TELEX 65 5421 1b

Kin. Tech Divisi:n Pa CIFIC

(' g SCIENTIFIC July 19, 1985 6000-05-177-85 Southern California Edison Cmpany I P. O. Box 700 San C1 mente, California 92672 Attention: Quality Control Manager

Subject:

Potential Probim with Pipe Clamps Gentionen:

Basic Engineers Division of National Valve and Mmuracturing Ccrpany has advised us of a potential probim with 3/4" and 1" pipe clamps manufactured by their firm. Cleveland Electric Illuminating Ccrpany has reported this to NRC as a 10 CFR 50.55e probim at the Perry Nucicar Station. The probim entails slippage of the clanp circtinferentially around the pipe due to conditions in installation.

Correction of the prob 1 m requires an increase in torque values for the clanp bolts which in scre cases may require new bolts and nuts.

( .

Sectico IV of the PSCo No.141 installation manual has been revised to reflect the new torque values and a copy is enclosed for your utilization.

The folicwing pipe cla ps previously shipped to your fim are involved:

PSco Part N e ber 1802001-010 P. O. Number Tag N eber Clapp Serial Nmber v4141293 tran mittal 16298 NA PS 10155 PS 10156 PS 10159 V4141293 transmittal 16263

  • PS 10160 V4141293 transmittal 15088
  • PS 15191 - PS 15193 PS 10177 - PS 10183 PS 10185 - PS 10187 PS 10189 - PS 10193 PS 10195 PS 10197

(

1346 S. State College Souleverd, Anaholm, California 92003,(714) 714 $217, TELEX 65 5421

~, __ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _

r, .

  • Sduthern California Edism Cmpany Attention: Quality Control Manager July 19,1985

Subject:

Page 2 Potential Problan with Pipe C1mps 6000-OS-177-85

( i PSCD Part thnber 1802001-010 P. O. Nater Tag Ntuber Clamp Serial Nt.rbar V4141293 transmittal 20043 NA PS 10111 PS 10113 PS 10117 PS 10114 PS 10112 PS 10127 V4141293 transmittal 14385 52-GR-052-H004 P3 10119 V4141293 transnittal 16203 53-SI-ll7-H001 PS 10131 Should you require replaccrent SA193-B7 bolts and SA194-2H nuts in your application of these clamps, they will be furnishcd to you upon request to Floyd Frodrickscm, Manager Nuc1 car Sales.

Very truly yours, PACIFIC SCI}NTIFIC Kin-Tech Divisim E. R. Thcrsen, M1 nager Quality Systcru and Services ERT:Im Attac? rent cc: Floyd Fredricksm

r-Kin. Tech Divisicn '

l Pa CIFIC

( ~, SCIENTIFIC July 19, 1985 Arizona Public Service Cmpany 6000-05-170-85

% Bechtel Power Corporation P. O. Box 49 Palo Verde, Arizcna 85343 Attenticn Quality control Panager w

Subject:

Potential Probim with Pipe Clanps Gentiment Basic Engirocrs Division of National Valve and Mmufacturing Ccrpany has advised us of a potential probim with 3/4" and 1" pipe clamps mnufactured by their fim. Cleveland Electric Illuninating Ccopany has reported this to NBC as a 10 O'R 50.55e problan at the Perry Nacicar Staticn. Tbc probim entails slippage of the c1mp circunferentially around the pipe due to conditicms in insta11aticn.

Correction of the probim rcquires an increase in torque values for the clag bolts which in scro cases rnay recpire new bolts and nuts.

( Sdcm IV of the PSCo No.141 installaticn snanual has been revised to reficct the new torque values ard a copy is enclosed for your utilizatien.

The following pipe clamps previously shipped to your fim are involved:

PSCo Part Nmber 1802001-010 P. O. thrber Tag N mber Clamp Serial Number 10407-13-TM-209B (PS 37229) 3-Clf-026-II-00X Pev. O PS 15113 3-OI-026-l!-00Y Fev. O PS 15118 (PS 37198) 3-PC-116-ll M Rev. O PS 15119 3-01-020-!!-000 Rev. O PS 15122 3-nc-122-l!-0AX Rev. O PS 15133 (PS 27188) 2-BC-116-II-CAP Pav. O PS 15134 2-DC-116-II-OAQ Pav. O PS 15131 2-BC-122-II M Rev. O PS 15120 (PS 27229) 2-OI-026-11-00Y Rev. O PS 15121 2-OI-024-II-OAE Pav. O PS 15123 2-CI-026-II-00X Rev. O PS 15125 2-Cit-026-11-002 Rev. O PS 15135 (PS 37229) 3-01-024-116 Rev. O PS 15129 3-01-026-11-002 Rev. O PS 15124 1346 S. State College Soulevard, Anaholm, California 92803,(714) 774 $217, TELEX 65 5421 S

F. .

Ariscna Service Ocupery maly 19,1985

, Attention: Quality control Manager Page 2

Subject:

Potential Problen with Pipe Clangs 6000-06-170-85

(

PSCO Part thaber 1802001-010 P. O. thaber Tag 1kaber Clamp Serial Number 10407-13-P&2098 (PS 27216) 2-E-104-H-00Y Rev. O PS 15126

. 2-E-104-H-000 Rev. 2 PS 15128 2-E-146-N-0(E Rev. O PS 15130 (PS 27238) 24lH-022-H-ChD Rev. O PS 15127 (PS 37216) 3-E-104-H-00Y Rev. O PS 15132 3-RC-104-H-000 Rev. 2 PS 15138 7,, 3-RC-146-H-00K Rev. O PS 15143 (PS 37295) 3-OI-020-H-0M Rev. O PS 15139 (PS 27181) 3-RC-Il6-H4XA Rev. O PS 15142 3-SG-348-H-00C Rev. O PS 15145 (PS 36245) 3-SI-224-H-008 Rev. O PS 15101 (PS 37283) 3-SI-189-H-008 Rev. O PS 15144 (PS 26356) 2-SI-170-H-008 Rev. 1 PS 15102 (PS 36356) 3-SI-170-H-008 Rev. 1 PS 15103

( (PS 37238) 3 G-022-H-04D Rev. O PS 15114 (PS 26165) 2-SI-224-H-008 Rev. O PS 10147 (PS 6165) 1-SI-224-H-008 Rev. O PS 10145 (PS 6365) 1-SI-170-H-008 Rev. 1 PS 10110 Should you require replaounent S4193-B7 bolts and SA194-2H nuts in your applicaticm of these clanps, they will be furnished to you upon request to Floyd Fredrickson, Manager Nuclear Sales.

Very truly yours, PACIFIC SCIINTIFIC -

Kin-Tech Division A*=J E. R. , Manager Quality systems and Servions ERT:Ima Att+3 - .^,

( oes Floyd Fredrickson

, e, #

, 8, e e ,t.

g

Kin Tech Divisi:n W Pa CIFIC

( .. SCIENTIFIC July 19, 1985 6000-OS-171-85 CIEMSA S.A.

Calle Viarnante 640 Piso Cuart6 -'

oficina 11 Buenos Aires, 1053 Republic of Argentina Attenticn: Quality Control Manager

Subject:

Potential Probim with Pipe C1m:ps Gentle,en:

Basic Engineers Division of National Valve and Rmufacturing Ccrpany has advised us of a potential probim with 3/4" and 1" pipe ~

clamps manufactured by their fim. Cleveland Electric Illuminating Ccrpany has reported this to NRC as a 10 CFR 50.55e probim at the Perry Nuclear Station. The probim entails slippage of the clanp ciretsnferentially around the pipe due to conditions in installation.

Correction of the probim requires an increase in torque values for the clamp bolts which in scre cases may require new bolts and nuts.

Section IV of the PSCo No.141 installation manual has been

( revised to reflect the new torque values and a copy is enclosed for your utilization.

The following pipe clm:ps previously shipped to your fim are involved:

PSCo Part Number 1802001-010 P. O. Ntsnber Tag Ntrnber Clarp Serial Ntr9ber PS-004 N/A '

PS 15104 PS 15111 PS 15112 Should you require replacment SA193-B7 bolts and SA194-2H nuts _

in your applicaticn of these clarps, they will be furnishal to you upm request to Floyd Fredrickson, Kinager Nuclear Sales.

Very truly yours, PACIFIC SCIEtif1FIC Kin-Tech Division W

[E. . Kzr.en, Manaaer C Quality Systms and' Services ERT:Imn oc Floyd Fredrickacn Attac}rnent 1346 8. State College Bouleyerd Anaholm, California 92603,(714)774 5217, TELEX 65 5421

,, Kin Tech Divisi:n Pa ClFIC

( .

1 SCIENTIFIC July 19, 1985 6000-05-173-85 Georgia Power Canpany P. O. Box 282 Waynesboro, Georgia 30830 Attenticn: Quality Control Manager

Subject:

Potential Probim with Pipe Clarrps Genticnen:

Basic Engineers Division of National Valve and Panufacturing Ccrn;nny has advised us of a potential probim with 3/4" and 1" pipe clamps mnutactured la' their fim. Cleveland Electric Illuntinating Ccopany has reported this to NRC as a 10 CFR 50.55c prob 1m at the Perry Nuclear Station. 'Ihe probim entails slippage of the clarnp circumferential1y around the pipe due to conditions in installation.

Correction of the probim requires an increase in torque values for the clamp bolts which in scre cases may require new bolts and nuts.

( Secticm IV of the PSCo No.141 installation manual has been revised to reflect the new torque values and a copy is enclosed for your utilization.

The folicwing pipe clamps previously shipped to your firm are involved:

PSCo Part Nunber 1802002-010 P. O. N mber Tag Number Clarnp Serial Number PAV-1608 Reg. No. 1X4AQ18 Vl-2702-009-H014,P.C. 414 PS 20102 PSCo Part Ntnber _1802001-010 PAV-1608 Reg. No.1X4AQ18 Vl-2702-009-H004,P.C.414 PS 15137 V1-1208-449-H008,P.C.lll PS 15136 N/A PS 10128 PS 10126 PS 10120 PS 10124 PS 10122 a "

PS 10121

( "

PS 10123 PS 10142 PS 10116 PS 10125 13465. State College Boulevard, Anaheim, California 92803,(714) 774 5217, TELEX 65-5421

~

4 o - ' -

~

. Georgin Power Company July 19, 1985 Attention: Quality Control Manager Page 2

Subject:

Potential Problem with Pipe Clangs 6000-QS-173-85

( e PSCO Part Ntsnber 1802001-010 P. O. Ntznber Tag Ntanber Clamp Serial Ntanber PAV 2-81 Req. No. 2X4AQ18 VA-1210-052-H029,P.C.313 PS 10144 VA-1210-129-H030,P.C.313 PS 10115 PAV 1608 Reg. No.1X4AQ18 VI-1901-315-H003,P.C.427 PS 15116 VI-1208-449-H003,P.C.lll PS 15115 vl-1208-449-H002,P.C.lll PS 15117 PAV 2-81 Req. No. 2X4AQi8 V2-1301-220-H001,P.C.424 PS 15148 V2-1301-220-H002,P.C.424 PS 15149 PAV-1608 Reg. No.1X4AQ18 Vl-1301-220-H001,P.C.424 PS 15147 Vl-1301-220-H002,P.C.424 PS 15146 l PSCO Part Ntanber 1802001-0075 4

PAV 1608 Reg. No. IX4AQ18 M-1208-049-H008,P.C.212 PS 175520

M-1208-050-H001,P.C.212 PS 17523 Vl-1208-050-H002,P.C.212 PS 17524 i

Vl-1208-025-H001,P.C.212 PS 17525 M -1201-238-H002,P.C.111 PS 175522 M -1208-049-H007,P.C.212 PS 17549 Vl-1208-025-H002,P.C.212 PS 17533 Vl-1208-049-H002,P.C.212 PS 17531 M -1208-049-H001,P.C.212 PS 17532 V1-1208-049-H003,P.C.212 PS 17528 V1-1201-239-H001,P.C.lll PS 17527 M -1204-108-H018,P.C.212 PS 17526 M -1204-108-H005,P.C.212 PS 17529 vi-1204-108-H019,P.C.212 PS 17530 PAV 2-81 Beq. No. 2X4AQ18 V2-1201-239-H001,P.C.111 PS 175521 Should you require replacment SA193-B7 bolts and SA194-2H nuts

, in your application of these clanps, they will be furnished to you upon request to Floyd Fredrickson, knager Nuclear Sales.

Very truly yours, PACIFIC SCIENTIFIC Kin-Tech Division 44 E. R. ,

i g,g Quality systems and Servious Attachment ocs Floyd Fredricketm

Kin.Tcch Divisisn W Pa CIFIC

(  ;

' SCIENTIFIC July 19, 1985 6000-05-174-85 ITI Grinnell Corporaticn 621 Dana Street N. E.

Warren, Ohio 44481 Attention: Quality Control Manager

Subject:

Potential Probi m with Pipe Clamps Gentlemen:

Basic Engineers Division of National Valve and Panufacturing Ccrapany clamps has advised manufactured by theirusfim.

of a potential probim with 3/4" and 1" pipe Perry Nuclear Station.Ccrqmf has reported this to NRC as a 10 CPR The probim entails slippage of the c1mp Correction of the probim requires an increase r in torq the clamp bolts which in scxte cases may require new bolts and nuts .

Secticn IV of the PSCo No.141 installaticn manual has been

( revised your to reflect utilization. the new torque values and a copy is enclosed for The following pipe clamps previously shipped to your fim are involved:

PSCo Part Ntznber 1802001-010 P. O. Ntznber Tag Number NAR 68074 Clamp Serial Ntznber N/A PS 10148 in your application of these clamps, they will be furnis upon request to Floyd Fredrickson, Panager Nuclear Sales.

Very truly yours, PACIFIC SCIETTIFIC Kin 'Ibch Division E. R. 'Ihcrnse%N n, Panager Quality Systans and Services ERT:Inm Attachment oc: Floyd Fredrickscm 1346 S. State Collego Boulevard, Anaheim,Cetifornia 41 92803 (714) 774 5217 TE

$g ..

- \

, Kin Tcch Divisi"sn I

Pa CIFIC l

( , SCIENTIFIC July 19, 1985 6000-OS-172-85 Florida Ppwer & Light Cmpany P. O. Box 029950 Miami, Florida 33102 Attenticm: Quality Control Manager

Subject:

Potential Proble with Pipe Clamps Gentimen:

Basic Engineers Division of National Valve and Manufacturing Ccnpany has advised us of a potential proble with 3/4" and 1" pipe clamps manufactured by their fim. Cleveland Electric Illminating Ccrpany has reported this to NRC as a 10 CFR 50.55e proble at the Perry Nuclear Staticn. The probim entails slippage of the clap circurnferentially around the pipe due to conditions in installaticn.

Correction of the probim requires an increase in torgae values for the clamp bolts which in scoe cases may require new bolts and nuts.

( Secticn IV of the PSCo No.141 installaticn manual has been revised to reflect the new torque values and a copy is enclosed for your utilizaticn.

, The follcuing pipe clamps previously shipped to your fim are 2nvolved:

PSCo Part Nmber 1802001-010 P. O. Nmber Tag Ntrnber Clamp Serial Number 65255-25004B N/A PS 10157 PS 10158 PS 10161 PS 10162 PS 10163 PS 10143 PS 10129 PS 10130

. PS 10146 PS 10118

(

j 1346 S. State College Bouleverd, Anaheim, Callfornia 92803,(714) 774 5217, TELEX 65 5421 I .

o,

  • l Florida Power & Light capany July 19, 1985 I

Attention: Quality Control Manager Page 2

Subject:

Potential Problern with Pipe Clanps 6000-OS-172-85

( c Should you require replacement SA193-B7 bolts and SA194-2H nuts in your application of these clarnps, they will be furnished to you upon request to Floyd Fredrickson, Manager Nuclear Sales.

. Very truly yours, PACIFIC SCIDTTIFIC Kin-Tech Division ,.

E. R. 'Ihcznsen, Mmager Quality Systans and Services

  • ERT:Imn Attac! rent oc: Floyd Fredrickscm

( _

c

='

.[

p F '

  • ' ,__ _. , 9 - *

.s .

1 I Kin Tech DiviSinn W Pa CIFIC

(,

7 SCIENTIFIC July 19, 1985 6000-05-176-85

~

Pwer Piping Cmpany 829 Beaver Avenue Pittsburgh, Pennsylvania 15233 Attention: Quality Control Panager

Subject:

Potential Problen with Pipe Clamps Gentlenen:

Basic Engincors Division of National Valve and Fanufacturing Ccrpany has advised us of a potential probim with 3/4" and 1" pipe clamps manufactured by their fim. Cleveland Electric Illuninating Ccr:pany has reported this to NRC as a 10 CFR 50.55e probim at the Perry Nuclear Station. 'Ihe probim entails slippage of the c1mp circumferentially around the pipe due to conditions in installaticm.

Correction of the probim requires an increase in torque values for the clamp bolts which in scxne cases tray require new bolts and nuts.

{

Section IV of the PSCo No.141 installation manual has been revised to reflect the new torque values and a copy is enclosed for your utilization.

The following pipe clamps previously shipped to your fim are involved:

PSCo Part Number 1802001-010 P. O. Nunber Tag Number C1 m p Serial Ntznber 19218-5280N HF-136 PERRY I & II N/A PS 10164 - PS 10175 PSCo Part Nunber 1802001-0075 38695-5280N HF-464 PERRY I N/A PS 175208 PS 175250 - PS 175291 PS 175293 - PS 175326 PS 175328 - PS 175349 PS 175450 - PS 175452 PS 175458 - PS 175459 PS 175462 PS 175464

( PS 175467 PS 175469 - PS 175470 PS 175454 - PS 175456 1346 S. State College Bouleverd Anaheim, California 92803,(714) 774-5217, TELEX 65 5421 i

l ~,., _ g - - - -

( Power Piping Cm pany Attenticrn Quality Cm tzel Manager July 19, 1985

Subject:

Page 2 Potential Proble with Pipe Clanps 6000-OS-176-85 PSCo Part Number 1802001-0075 P. O. Ntnber Tag Number Clamp Serial Ntnber 38695-5280N HF-464 PERRY I N/A PS 175472 - PS 175476 PS 175479 - PS 175481 PS 175483 PS 175485 - PS 175490 PS 175492 - PS 175495 PS 175497 - PS 175509 PS 175512 PS 175515 - PA 175519 PS 175171 - PS 175172 PS 175175 - PS 175178 PS 175181 - PS 175182

{ PS 175185 PS 175187 - PS 175188 PS 175194 - PS 175195 PS 175203 - PS 175204 PS 175210 - PS 175211 PS 175216 PS 175219 PS 175220 - PS 175221 PS 175225 PS 175227 PS 175229 PS 175233 PS 1;5235 - PS 175236 PS 175238 PS 175242 PS 175327 PS 175453

{ PS 175457 PS 175460 - PS 175461 PS 175292

'% . . I

(

(\

Power Piping Canpany July 19, 1985 Attention:,' Quality control Manager Page 3

Subject:

Potential Problen with Pipe Clanps 6000-OS-176-85 PSCo Part Ntrnber 1802001-0075 P. O. Tag Ntznber Clamp Serial Ntanber 38695-5280N HF-464 PERIE I N/A PS 175463 PS 175465 - PS 175466 PS 175468 & PS 175471 PS 175477 - PS 175478 PS 175482 PS 175484 PS 175491 PS 175496 PS 175510 PS 175511 PS 175513 PS 175514 PS 175170 PS 175173 PS 175174 PS 175179 - PS 175180 PS 175183 - PS 175184 PS 175186 PS 175189 - PS 175193 PS 175196 - PS 175202 PS 175205 - PS 175207 PS 175209 PS 175212 PS 175213 - PS 175215 PS 175217 - PS 175218 PS 175222 - PS 175224 PS 175226 PS 175228

{ PS 175230 - PS 175232 PS 175234 PS 175237 s . _

t.

Pcur Piping Campany Attention: Quality Control Manager July 19, 1985

(

Subject:

Potential Prob 1m with Pipe C1mps

, Page 4 6000-05-176-85 PSCo Part Number 1802001 0075 P. O. Number Tag Ntznber Clamp Serial Ntznber 38695-5280N HF-464 PERE I N/A PS 175239 - PS 175241 PS 175350 - PS 175449 PS 175243 - PS 175249 PS 175150 - PS 175169 PS 17550 - PS 17599 PS 175100 - PS 175149 .

Should you require rer'acenent SA193-B7 bolts and SA194-2H nuts in your application of the~e clamps, they will be furnished to you upon regmst to Floyd Fredrickson, Manager Nuclear Sales.

Very truly yours, PACIFIC SCIENTIFIC Kin-Tech Division E. R. Thcrnsen, Manager Quality Systans and Services ERT: Inn Attachant oc: Floyd Fredrickson

(

l l __  % ,

.) Kin Tech Divisien -

PaClFIC

( , SCIENTIFIC July 19,1985 N@ 6000-OS-175-85 Servizio Anninstrazione Piazza Carignano 2 Casella Postate N. 1166 16128 - Genova .

Italy Attention: Quality Control Manager

Subject:

Potential Probim with Pipe Clanps Contimen:

Basic Engineers Division of National Valve and Manufacturing '

Cmpany has advised us of a potential probim with 3/4" and 1" pipe clamps manufactured by their fim. Cleveland Electric Illminating Ccrpany has reported this to hPC as a 10 CFR 50.55e probim at the Peny Nuclear Staticn. The probim entails slippage of the clarnp circuntferentially around the pipe due to conditions in installation.

Correction of the probi m requires an increase in torque values for the clamp bolts which in scrie cases may require new bolts and nuts.

( Secticn IV of the PSCo No.141 installation manual has been revised to reflect the new torque values and a copy is enclosed for your utilizaticn. l

, The follcuing pipe clamps previously shipped to your fim are involved: ,

PSCo Part Number 1802001-0075 t P. O. N mber Tag N mber Clamp Serial Nmber t 3072/DID JOB (382.309) N/A PS 17522 f

PS 17501 thru PS 17521 3072/DID 05 (382.309) dtd. 7/2/82 PS 17534 thru PS 17548 '

3072/DID JN (382.309) Part Nmber 1802001-0075 PS 10176  !

PS 10184 PS 10188 PS 10199 PS 10194 PS 101%

PS 10198 1346 S. State College Boulevard, Anaholm, California 92803,(714) 774-5217, TELEX 65-5421 s

-._9 ,

.' NIRA spa July 19, 1985 Attention: Quality Cmtrol Manager Page 2

Subject:

Potential Proble with Pipe Clanps 6000-OS-175-85

( J Should you require replaosnent SA193-B7 bolts and SA194-2H nuts in your application of these clarps, they will be furnished to you upon request to Floyd Fredrickscm, Manager Nuclear Sales.

very truly yours, PACIFIC SCIDfrIFIC Kin-Tech Divisicm E. R. Thmsen, Manager Quality Systans and Services ERT:lm Attachnent oc: Floyd Fredrickscm

.. .. . -