MONTHYEARML20236K7731987-10-31031 October 1987 Monthly Operating Rept for Oct 1987 ML20235W3781987-09-30030 September 1987 Monthly Operating Rept for Sept 1987 ML20238E2741987-08-31031 August 1987 Monthly Operating Rept for Aug 1987 ML20235H3151987-06-30030 June 1987 Monthly Operating Rept for June 1987 ML20214W3241987-05-31031 May 1987 Monthly Operating Rept for May 1987 ML20214R5101987-04-30030 April 1987 Rev 1 to Monthly Operating Rept for Apr 1987,correcting Operation Statistics & Shutdown Experience Due to Mathematical Errors ML20215L4941987-04-30030 April 1987 Monthly Operating Rept for Apr 1987 ML20210B4141987-03-31031 March 1987 Revised Monthly Operating Rept for Mar 1987 ML20206F3561987-03-31031 March 1987 Monthly Operating Rept for Mar 1987 ML20212P3101987-02-28028 February 1987 Monthly Operating Rept for Feb 1987 ML20210R6341987-01-31031 January 1987 Monthly Operating Rept for Jan 1987 ML20207M2451986-12-31031 December 1986 Monthly Operating Rept for Dec 1986 ML20215C7911986-11-30030 November 1986 Monthly Operating Rept for Nov 1986 ML20213F3121986-10-31031 October 1986 Monthly Operating Rept for Oct 1986 ML20215G1081986-09-30030 September 1986 Monthly Operating Rept for Sept 1986 ML20212F5321986-07-31031 July 1986 Monthly Operating Rept for Jul 1986 ML20202G3371986-06-30030 June 1986 Monthly Operating Rept for June 1986 ML20211B5601986-05-31031 May 1986 Monthly Operating Rept for May 1986 ML20197D2651986-04-30030 April 1986 Monthly Operating Rept for Apr 1986 ML20155C6461986-03-31031 March 1986 Monthly Operating Rept for Mar 1986 ML20137Y2631986-02-28028 February 1986 Monthly Operating Rept for Feb 1986 ML20214B9131986-01-31031 January 1986 Monthly Operating Rept for Jan 1986 ML20137B3711985-12-31031 December 1985 Monthly Operating Rept for Dec 1985 ML20137Z0901985-11-30030 November 1985 Monthly Operating Rept for Nov 1985 ML20136A7121985-10-31031 October 1985 Monthly Operating Rept for Oct 1985 ML20133J0521985-09-30030 September 1985 Monthly Operating Rept for Sept 1985 ML20133J0651985-08-31031 August 1985 Revised Monthly Operating Rept for Aug 1985 ML20135F9861985-08-31031 August 1985 Monthly Operating Rept for Aug 1985 ML20134D9611985-07-31031 July 1985 Monthly Operating Rept for Jul 1985 ML20132F6251985-06-30030 June 1985 Monthly Operating Rept for June 1985 ML20135G0641985-06-30030 June 1985 Revised Monthly Operating Rept for June 1985 ML20126L7141985-05-31031 May 1985 Monthly Operating Rept for May 1985 ML20135F9921985-04-30030 April 1985 Revised Monthly Operating Rept for Apr 1985 ML20127G2481985-04-30030 April 1985 Monthly Operating Rept for Apr 1985 ML20115C9401985-03-31031 March 1985 Monthly Operating Rept for Mar 1985 ML20112D9131985-02-28028 February 1985 Monthly Operating Rept for Feb 1985 ML20106J3801985-01-31031 January 1985 Monthly Operating Rept for Jan 1985 ML20112H8071984-12-31031 December 1984 Monthly Operating Rept for Dec 1984 ML20101B1871984-11-30030 November 1984 Monthly Operating Rept for Nov 1984 ML20099C6941984-10-31031 October 1984 Monthly Operating Rept for Oct 1984 ML20093E3861984-09-30030 September 1984 Monthly Operating Rept for Sept 1984 ML20097C7951984-08-31031 August 1984 Monthly Operating Rept for Aug 1984 ML20094N2661984-07-31031 July 1984 Monthly Operating Rept for Jul 1984 ML20090B8591984-06-30030 June 1984 Monthly Operating Rept for June 1984 ML20091M8741984-05-31031 May 1984 Monthly Operating Rept for May 1984 ML20084H8601984-04-30030 April 1984 Monthly Operating Rept for Apr 1984 ML20088A1681984-03-31031 March 1984 Monthly Operating Rept for Mar 1984 ML20087A9181984-02-29029 February 1984 Monthly Operating Rept for Feb 1984 ML20087A5401984-01-31031 January 1984 Monthly Operating Rept for Jan 1984 ML20086N0061984-01-31031 January 1984 Monthly Operating Rept for Jan 1984 1987-09-30
[Table view] Category:TEXT-SAFETY REPORT
MONTHYEARML20217A1691999-09-22022 September 1999 Part 21 Rept Re Engine Sys,Inc Controllers,Manufactured Between Dec 1997 & May 1999,that May Have Questionable Soldering Workmanship.Caused by Inadequate Personnel Training.Sent Rept to All Nuclear Customers RA-97-0258, LER 97-S12-00:on 971119,discovered Uncompensated Security Zone.Caused by Inattention to Detail by Members of Security Force.Provided Event Info to Security Shift Personnel & Changed Practice Re Zone Review1997-12-19019 December 1997 LER 97-S12-00:on 971119,discovered Uncompensated Security Zone.Caused by Inattention to Detail by Members of Security Force.Provided Event Info to Security Shift Personnel & Changed Practice Re Zone Review ML20211M6491997-10-0808 October 1997 Addenda 1 to Part 21 Rept Re Weldments on Opposed Piston & Coltec-Pielstick Emergency stand-by Diesel gen-set lube-oil & Jacket Water Piping Sys.Revised List of Potentially Affected Utils to Include Asterisked Utils,Submitted ML20217Q2751997-06-30030 June 1997 CP&L Fitness for Duty Program Performance Data for Period 970101-0630 ML14183A6951995-09-18018 September 1995 Safety Evaluation Approving Relocation of Technical Support Ctr ML20059H7721994-01-17017 January 1994 Part 21 Rept Re Virginia Power Notifying Fairbands Morse Via Failure Analysis Rept NESML-Q-058 of Defective Air Start Distributor cam,16104412 ML17352A8691993-05-31031 May 1993 Technical Rept, Assessment of Aging Degradation of Civil/ Structural Features at Selected Operating Nuclear Power Plants. ML20125C7161992-12-0707 December 1992 Part 21 Rept Re Possibility for Malfunction of Declutching Mechanisms in SMB/SB-000 & SMB/SB/SBD-00 Actuators. Malfunction Only Occurs During Seismic Event.Balanced Levers May Be Purchased from Vendor.List of Affected Utils Encl ML20127P5861992-11-23023 November 1992 Followup to 921005 Part 21 Rept Re Potential Defect in SB/SBD-1 Housing Cover Screws.Procedure Re Replacement of SBD-1 Spring Cover Bolts Encl.All Fasteners Should Be Loosened & Removed.List of Affected Utils Encl ML20118B4391992-09-11011 September 1992 Part 21 Rept Re Degradation in Abb Type 27N Undervoltage Relays Used in Electrical Switchgear.Recommends That Users Review Applications Requiring Exposures Greater than 1E03 Rads TID W/Time Delay Function Option ML20079H1571991-09-30030 September 1991 Nonproprietary Evaluation of Revised Transfer to Cold Leg Recirculation Procedure,Hb Robinson Unit 2 ML20086T2951991-06-14014 June 1991 Rev 1 to EQ Documentation Package Eqdp 36.0, Boston Insulated Wire Cable ML20086T2861991-03-0808 March 1991 Rev 1 to EQ Documentation Package Eqdp 11.1, Dekoron Instrumentation Cables ML20086T2561991-03-0808 March 1991 Rev 1 to EQ Documentation Package 10.0, Continental Shielded Instrument Cable ML20065K6961990-10-31031 October 1990 Mechanical Licensing Rept for Hb Robinson High Thermal Performance Fuel Assemblies ML20065K6971990-10-31031 October 1990 Thermal Hydraulic Compatibility Analysis of Anf High Thermal Performance Fuel for Hb Robinson,Unit 2 ML20005G6831990-01-0505 January 1990 Part 21 Rept Re Installation Instructions for Grommet Use Range for Patel Conduit Seal P/N 841206.Conduit Seals in Environ Qualification Applications Inspected for Proper Wire Use Range & Grommets Replaced ML20247E0701989-07-20020 July 1989 Info Rept:On 890717-0804,fire Penetration Seals Will Be Removed from Svc to Allow Access for Ventilation Sys Mod. Addl Fire Barrier Penetrations Will Be Made in Wall Between RHR Pump Pit & Fuel Handling Bldg,Per Tech Spec 3.14.7.2 ML20246E9111989-03-31031 March 1989 PDC-3:Advanced Nuclear Fuels Corp Power Distribution Control for PWRs & Application of PDC-3 to Hb Robinson Unit 2 ML20245H0821989-01-25025 January 1989 Criticality Safety Analysis of Hb Robinson Spent Fuel Pool W/4.2% Nominal Enrichment Fuel Assemblies ML20205T0551988-10-31031 October 1988 Responses to NRC Questions on RTD Bypass Elimination Licensing Rept ML20147E2371988-02-29029 February 1988 1987 Annual Rept - Primary Coolant Iodine Spikes ML20147B1971987-12-31031 December 1987 1987 Annual Rept - Primary Safety & Relief Valve Challenges ML20236K7731987-10-31031 October 1987 Monthly Operating Rept for Oct 1987 ML20235W3781987-09-30030 September 1987 Monthly Operating Rept for Sept 1987 ML20238E2741987-08-31031 August 1987 Monthly Operating Rept for Aug 1987 ML20235H3151987-06-30030 June 1987 Monthly Operating Rept for June 1987 ML17261A5301987-06-18018 June 1987 Part 21 Rept Re Potential Util Failure to Comply W/Component Containment Isolation Licensing Commitment If Proposed Mods to Component Cooling Water Sys Instituted.Utils Advised to Evaluate Containment Isolation Sys ML20214W3241987-05-31031 May 1987 Monthly Operating Rept for May 1987 ML20214R5101987-04-30030 April 1987 Rev 1 to Monthly Operating Rept for Apr 1987,correcting Operation Statistics & Shutdown Experience Due to Mathematical Errors ML20215L4941987-04-30030 April 1987 Monthly Operating Rept for Apr 1987 ML20206F3561987-03-31031 March 1987 Monthly Operating Rept for Mar 1987 ML20210B4141987-03-31031 March 1987 Revised Monthly Operating Rept for Mar 1987 ML20205F6021987-03-23023 March 1987 Special Rept:On 870302,noble Gas Effluent Monitor for Main Steam Line B Declared Inoperable & Svc Not Returned Until 870312.Caused by Defective Detector.Detector Replaced.High Voltage for Detector Adjusted & Sys Operation Checked ML20212P3101987-02-28028 February 1987 Monthly Operating Rept for Feb 1987 ML20214Q7891987-01-31031 January 1987 Cycle 12,SAR ML20210R6341987-01-31031 January 1987 Monthly Operating Rept for Jan 1987 ML20207M2451986-12-31031 December 1986 Monthly Operating Rept for Dec 1986 L-18-120, Rev 0 to Supplemental Info in Support of Conservatisms in Criticality Analysis Performed for Hb Robinson Isfsi1986-12-18018 December 1986 Rev 0 to Supplemental Info in Support of Conservatisms in Criticality Analysis Performed for Hb Robinson Isfsi ML20215C7911986-11-30030 November 1986 Monthly Operating Rept for Nov 1986 ML20213F3121986-10-31031 October 1986 Monthly Operating Rept for Oct 1986 ML20215G1081986-09-30030 September 1986 Monthly Operating Rept for Sept 1986 ML20215F0361986-09-29029 September 1986 Special Rept:On 860902,during Cold Shutdown,Pressurizer PORV Lifted Twice to Prevent Overpressurization.Caused by Inadvertent Action by Unit Operators.Operations Personnel Counseled Re Importance of Breaker Position Indicators ML20211C0641986-09-0909 September 1986 Rev 0 to Final Rept Criticality Safety Analysis Hb Robinson Spent Fuel Storage Racks (Unpoisoned,Low Density) W/4.2% Enriched 15x15 Fuel Assemblies ML20211C0491986-09-0202 September 1986 Rev 0 to Final Rept Criticality Safety Analysis Hb Robinson New Fuel Storage Vault W/4.2% Enriched 15x15 Fuel Assemblies ML20212F5321986-07-31031 July 1986 Monthly Operating Rept for Jul 1986 ML20203D0221986-07-14014 July 1986 Part 21 Rept Re Air Monitoring Sys Probes Exhibiting Blue Tip Rather than Normal White Tip & Insensitive to Chlorine. Caused by Improper Handling/Storage.Advisory Bulletin Encl. Item Not Reportable Per Part 21 ML20202G3371986-06-30030 June 1986 Monthly Operating Rept for June 1986 ML20211B5601986-05-31031 May 1986 Monthly Operating Rept for May 1986 ML20197D2651986-04-30030 April 1986 Monthly Operating Rept for Apr 1986 1999-09-22
[Table view] |
Text
D Encloun're fo Srrial: RUPD/05-30 ,
Pega 1 of 3 OPERATING DATA REPORT DOCKET NO. 050-0261 DATE 01/02/85 COMPLETED BY A. E. SCOTT TELEPHONE (803)383-4524 OPERATING STATUS
- 1. UNIT NAME: ROBINSON UNIT 2 i NOTES Itere are presently 222 I
- 2. REPORTING PERIOD: DECEMBER 84 l Fuel Assemblics in the Spent Fuel !
- 3. LICENSED THERMAL POWER (MWT): 2300 l Pool. I )
- 4. NAMEPLATE RATING (GROSS MWE) 739.0 l l
- 5. DESIGN ELECTRICAL RATING (NET MWE): 700.0 l l 6.' MAX DEPENDABLE CAPACITY (GROSS MWE): 700.0 l l
- 7. MAX DEPENDABLE CAPACITY (NET MWE): 665.0 -------------------------------
- 8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 THRU 7) SINCE LAST REPORT, GIVE REASONS:
- 9. POWER LEVEL TO WHICH RESTRICTED IF ANY (NET MWE); none 3:0. REASONS FOR RESTRICTION I,F ANY: None 9
THIS YR TO CUMUL MONTH DATE ATIVE
- 1. HOURS IN REPORTING PERIOD 744.00 8784.00 121230.00
- 2. NUMBER OF HOURS REACTOR CRITICAi. .00 616.07 84197.30
- 3. REACTOR RESERVE SHUTDOWN HRS .00 145.68 1937.07
- 4. HOURS GENERATOR ON LINE .00 615.78 82065.95
- 5. UNIT RESERVE SHUTDOWN HOURS ,00 .00 23.20
- 6. GROSS THERMAL ENERGY GEN. (MWH) .00 783895.20 162875234.16
- 7. GROSS ELEC. ENERGY GEN. (MWH) .00 246010.00 52344876.00
- 8. NET ELEC. ENERGY GENERATED (MWH) -5879.00 190037.00 49409661.00
- 9. UNIT SERVICE FACTOR .00 7.01 67.69
- 0. UNIT AVAILABILITY FACTOR .00 7.01 67.71
- 1. UNIT CAP. FACTOR (USING MDC NET) -i.19 3.25 61.29
- 2. UNIT CAP. FACTOR (USING DER NET) -1.13 3.09 58.22
- 3. UNIT FORCED OUTAGE RATE .00 57.24 15.17
- 4. SHUTDOWNS SCHED. OVER NEXT 6 MONTHS (TYPE, DATE, AND DURATION OF EACH): none
- 45. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF. START UP: 01-06-85
- 56. UNITS IN TEST STATUS (PRIOR TO COMMERCIAL OPERATION)- FORCAST ACHEIVED INITIAL CRITICALITY --- Z--- -- !!---
INITIAL ELECTRICITY -------- --------
~ -
COMMERCIAL OPERATION -- ZZ--- -- ZZ---
agat!!88R0%8hSj!A ,
R 1.16 - 9
[y;gegoh*l3
' AVERAGE DAILY POWER LEVEL-DOCKET NO. 050-0261 UNIT ROBINSON UNIT 2
'DATE 01/02/85 COMPLETED-BY A. E. SCOTT TELEPHONE (803)383-4524 EECEMBER 1984 LAY- AVG. DAILY POWER LEVEL- DAY AVG. DAILY POWER LEVEL (MWE-NET) (MWE-NET) 1 -10 17 -5 2 -10 18- -5 3 -10 19 -5 4 -10 20 -4 5~ -i2 21' -5
'6 -12 22 -5 7 23 -5 8- -12 24- -10 9 -8 25 -10
- 30. -4 26 31 -5 27- -10
}2 -4 28 -10' 33' -4 29, . -10 34 -4 30 -12 3-5 -5 31 '-13 36 -5
')
e
$ f 1.16 - 8' I
s UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO. nsn_n xi UNIT NAME H. B. Robinson DATE 850102 COMPLETED BY A. E. Scott REPORT MONTH December TELEPHONE 803-383-4524
":.C C
- 50 "E E3 Licensee E-t E% Cause & Cerrective No. Date h jj $ 3js Event
{~$ Action to I-f= $ j ;f3 g Report # vs O g Prevent Recurrence d
s 1201 841201 S 744 C 1 CJ IITEXC11 Continuation of refueling and steam generator replacement
, outage.
~.
s
\
i 2 3 4 F: Forced Reason: Method: Exhibit G - Inst ructions S: Scheduled A Equipment Failure (Explain) 1-Manual for Preparation of Data B-Maintenance of Test 2-Manual Scram. Entry Sheets for Lscensee C-Refueling 3 Automatic Scram. Event Report (LE R) File (NUREG-D-Regulatory Restriction 4-Other (Explain) 0161)
,n E-Operator Training & Ucense Examination F-Administrative 5
'i G-Operational Error (Explain) Exhibit 1 - Same Source (9/77) Il-Otter (Explain) n ,n E
n eAe
? *.
CD&L Carolina Power & Light Company ROBINSON NUCLEAR PROJECT DEPARTMENT POST OFFICE BOX 790 HARTSVILLE, SOUTH CAROLINA 29550 JAN .g;9g5 Robinson File No: 15505 Serial: RNPD/85-30 Mr. Richard C. DeYoung, Director Office of Inspection & Enforcement 4
U. S. Nuclear Regulatory Commission Washington, D. C. 20555 H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 DOCKET NO. 50-261 LICENSE NO. DPR-23 MONTHLY OPERATIONS REPORT
Dear Mr. DeYoung:
In accordance with Technical Specification 6.9.1.c for the H. B. Robinson Steam Electric Plant, Unit No. 2, Carolina Power & Light Company herewith submits the report of operation statistics and shutdown experience for the month of December, 1984.
i j Very truly yours, R
i General Manager H. B. Robinson S. E. Plant AES/tk
-Enclosure cc: R. A. Hartfield (2)
J. P. O'Reilly (1)
J t
. - .. _ - . --