Text
% -
LEndirsura th S$rialt RNPD/85-94'8-i
. wy -
lPagI 1.cf.4 OPERATING DATA" REPORT D0'KET'NO. 050-026i C
'y'.
4 DATE:
05/03/85 COMPLETED BY A. E. SCorT-TELEPHONE (803)303-4524 10PERATINCiSTATUS.
__._.._.__.___--_1_.a__
5-h.,U N I T N A M E c RODINSON' UNIT 2 i NOTES' There:are presently 222 -
f-
- 2. REPORTINGuPERIOD:jAPRIL _
35'
)
fuel assemblies in the Spent 1
13.' LICENSED THERMAL POWER <(MWT) ;2300--
- 1. Fuel Pool.
I
.!4.E NAMEPLATE 1 RATING (CROSS J.MWE) : _'739.0 f
.I l
- 5. DES.tGN'ELECTRICALKRATING-(NET-MWE). 700.0 t.
- I i.>tiAX-DEPENDABLE CAPACITY (GROSS.MWE)..700.0 1-E7; MAX-DEPENDABLE CAPACITY (NET MWE). 665.0
' 8'. -IF CHANG S- 0CCOR (IN ' CAPACITY RATINGS,.(ITEMS 3 THRU 7).SINCE LAST REPORT,-
l GIVEDREASONS:
F d.IPO'WER LEVEL-TO. WHICH - RESTRICTED IF ANY (NET MWE)
None '
^
' t G. 2:RCASONS FORLRESTRICTIC IF'ANY' None.
m 1p=
.THIS YR TO TCUMULL MONTH D f, TE ATIVE 11r HOLMS IN REPORilNG PER10D 71o 30-287(P.00--
-124iO9.00
- 12. NUMDER OF HOURS REAC10R CRITICAL.
696.47 2064.37
'86261.67 13;; REACTOR RESERVE THUTDOWN; HRS 22.53 70'l.95-2725.02 H. SOURS GENERATOR UN LINE
~694.67~
1944;32 84010.'27-A S.E UNIT. RESERVE JSH01 DOWN HOURS
.00
.00 23:20 T6-DROSSJfHERMAL ENERGY. GEN. (NUH)-
1565234.64 4067423.04 ~166942657.20' FtL7.IGROSS ELEC.# ENERGY CEN. mWH) 513607.00 i331091.00 33675967100-ffB.' NET-ELEC. ENO(GY GENERATED'(MWH) 489129.00.
1255414.00 50h65075.00-Lt 9. UNI T - SERVICE FACTOR 96.62
'67.53 67.69 201fuNIT' AVAILABILITY FACTOR 96.62 67 53
'67.71 21'.oVNIT CAPI FACTOR (USING MDC NETS 102i30-65.5'l
?61.39 22.< UNIT, CAP.--FACTOR (USING DER NET)-
97.18 62.29 58.32
- 23. UNIT i0RCED;0UTAGE RATE
'3.30
'27.22
=iS.47 24L SHUTDOWNS SCHED.-DVER NEXT 64 MONTHS 1 TYPE, DATE, AND DURATION OF EACH)-
23'.
IF--SHUTDOWN AT END.0F REPORT PERIOD, ESTIMATED DATE OF START UP 26;. UNITS--IN TESJ. STATUS (PRIOR TO COMMERCIAL OPERATION)
FORCAST ACHEIVED-INITIAlf CRITICALITY
+#-
IINITIAL' ELECTRICITY
-U-
~
.'CUMMERCIAL OPERATION 7 - --
61 7
PDR l
^
m
Paga 2.cf 4
~ " ~
APPENDIX'B AVERAGE DAILY POWER LEVEL DOCMET.NO. 050-0261 UNIT ROBINSON UNIT 2 DATE 05/04/85 COMPLETED DY A.
E.
SCOTT TELEPHONE (803)303-4524
- APRIL i'985 DAY-
~ AVG.' DAILY ~ POWER LEVEL DAY AVG. DAILY. POWER LEVEL (tiWE-NET)'
(MWE-NET) 9 Li'.
732 17
.725
'2-732 18 726 3.
?32 '
19 724
.4-731 20 724 4
4 3
730 21
'725 P
l
'6 659 22
~722
- 7' 664 23 721
~
8 61 24 723
-7 21 ~?
25 722 i 10 ~
^
674 26
'721
- 1 i-726 27 722
- 12 727 2a 722 Li 3 726
??
72i
~.i4 726 30 727 li5
~/ 2 5 '
(:
(16 725 L
I b,
f b^
a o
a 9
1R g3 Y o[f~O l ~
UNITSHUTDOWNS AND POWER REDUCh10NS DOCKET NO.
05b-0261 UNIT NAME H.
B. Robfnson DATE 850501 REPORTMONTH April COMPLETED BY Anita E.
Scott TELEPHONE 803-383-4524 w.
,E_ E 3
.E Licensee h
- L Cause & Corrective No.
Date R
EE il 2 s a:
Event p
g"g Act e'n to i
$E 5
j di g Report a mO Prevent Recurrence H
g d
i 0401 850406 S
B 2
ZZ TURBIN Unit load reduced to 66% reactor power to perform turbine valve test. 'While at reduced load, "B" heater drain pump was taken out-of-service for maintenance. Upon completion of maintenance, unit was returned to full load.
0402 850408 S
24.33 B
2 CB PUMPXX Unit was shutdown to repair the No. 2 seal on "C" Reactor Coolant Pump.
Investigation revealed that there is a generic problem with the presently installed seal design. The 0-ring material is to hard and tends to cause the No. 2 seal to hang up periodically-
"C" RCP seal parameters returned to normal and the unit was returned to service.
Transformer lighting i
2 3
4 F: Forced Reason:
Method:
Exhibit G. Instructions S: Scheduled A Equipment Failure (Explain) 1-Manual for Preparation of Data B-Maintenance of Test 2-Manual Scrain.
Entry Sheets for Licensee C-Refueling.
3-Automatic Scram.
Event Report (LER) File (NUREG-D-Regulatory Restriction 4-Other (Explain) 0161)
E-Operator Training & License Examination F-Administrative S
G-Operational Error (Explain)
Exhibit I Same Source -
(9/77)
Il-Other (Explain) f 9
m
Pcg3 4 cf 4 050-0261.,
UNITSHUTDOWNS AND POWER REDUCTIONS D3CKET NO.
UNIT NAME H. B. Robinson DATE 850501 REPORT MONTH April ~
COMPLETED BY Anita E.
Scott TELEPHONE 803-383-4524 I
'3 C
3 ud 5"
2 E
g.5 X Licensee g'r, c.
Cause & Corrective e
E.3 Action to No.
Daic g.
gg g
,g g cE Event u?
V
$E 5
j 65 g Report * -
A'0
[U Prevent Recurrence 5
~3 i
0402 850408 S
24.33 B
2 CB
-PUMPXX (Continued) arrestors were also replaced during-this shutdown.
l i
t i
2 3
4 F: Forced Reason:
Method:
Exhibit G Instructions S: Scheduled A-Equiprnent Failure (Explain) 1 Manual for Preparation of Data B-Maintenance or Test 2-Manual Scram.
Entry Sheets for Licensee C Refueling 3-Automatic Scram.
Event Report (LER) File (NUREG-D Regulatory Restriction 4-Other (Explain) 0161)
E-Operator Training & Ucense Examination F-Administrative S
G-Opciattunal Error (Explain)
Exhibit 1.Same Source (9/77) ll-Oaher (Explain)
- t
CP&L Carolina Power & Light Company m wx. z v :. x,..um m..,.
ROBINSON NUCLEAR PROJECT DEPARTMENT POST OFFICE BOX 790 HARTSVILLE, SOUTH CAROLINA 29550 MAY 8 1985 Robinson File :
15505 Serial:
RSEP/85-948 Mr. James M. Taylor, Director Office of. Inspection & Enforcement U. S. Nuclear Regulatory Commission Washington, D. C.
20555 H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 DOCKET NO. 50-261 LICENSE NO. DPR-23 MONTHLY OPERATIONS REPORT
Dear Mr. Taylor:
In accordance with Technical Specifications 6.9 1.c for the H. B. Robinson Steam Electric Plant, Unit No. 2, Carolina Power & Light Company herewith submits the report of operation statistics and shutdown experience for the month of April,1985.
Very truly yours, R. E.
rgan General Manager H. B. Robinson SEG Plant AES:tk/C-1112 Enclosure cc:
R. A. Hartfield (2)
J. P. O'Reilly (1) s6, 1
\\
-.