Enclosure t Serials RSEP/84-519 Page 1 of 3 OPERATING DATA REPORT DOCKET'NO. 050-026i DATE 00/01/04 COMPLETED UY A.
E.
SCOTT TELEPHONE (003)303-4524 OPERATING STATUS i
UNIT NAME-ROBINSON UNIT 2 l NOTET There are presently 1
2 REPORTING PERI'0D: JULY 04 1 379 Fuel Assemblies in the 1
3 LICENSED THERMAL POWER (MWT) 2300 l Spent Fuel Pool.
I 4<
NAMEPLATE RATING (GROSS MWE) 737.0 I
I S; DESIGN ELECTRICAL RATING (NET MWE) 700.0 l
l 6e tiAX DEPENDABLE CAPACITY (GROSS MWE) 700.0 l I
7c MAX DEPENDALLE CAPACITY (NET MWE) 665.0 0=
IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 TilRU 7) SINCE LAST REPORT, GIVE REASONS:
9e POWER LEVEL TO WHICH RESTRICTED IF ANY (NET MWE)
None ice REASONS FOR' RESTRICTION IF ANY:
N/A THIS YR TO CUMUL M0t4TH DATE ATIVE i1. HOURS IN REPORTING PERIOD 744.00 Siii.00 11755'7.00
- 12. NUNDER OF HOURS REACTOR CRITICAL
.00 616.07 04197.30
- 13. REACTOR RESERVE SHUTDOWN HRS
.00 3 0. (/ 3 1830.32
- 14. HOURS GENERATOR ON LINE
.00 615.70 02065.95
- 15. UNIT RESERVE SilUTDOWN HOURS
.00
.00 23.20
- 16. GROSS TIIERMAL ENERGY GEN. (MWH)
.00 703095.20 *162075234.16
- 17. GROSS ELEC. ENERGY GEN. (MWH)
.00 246010.00 52344076.00
- 10. NET ELEC. ENERGY GENERATED (MWil)
-i4Y7.00 211761.00 49431505.00
- 19. UNIT SERVICE FACTOR
.00 12.05 67.01
- 20. UNIT AVAILADILITY FACTOR
.00 12.05 69.03
-.30 6.24 63.23
- 22. Ut4IT CAP. FACTOR (USING DER NET)
.2Y 5.92 60.07
- 23. UNIT FORCED OUTAGE RATE
.00 57.24 15.17
- 24. SHUIDGWNS SCllED. OVER NEXI 6 MONillS (TYPE, DATE, AND DURATION OF EACll)
- 25. IF SHUTDOWN AT END OF REPORT PERIOD, FSTIMATED DALE OF START UP 10-25-84
- 26. UNIIS IN TEST SIATUS O'R10k TO COMt1ERCIAL OPERA 110N)
FORCAlCi ACHEIVED INITIAL CRITICALITY INIIIAL ELECTRICITY COMtiERCIAL OPERArt.ON 0400160144 040731 I I 0 ~,',
PDR ADOCK 05000261 R
PDR ij
nc osure t Seriait RSEP/84-519
)
Page 2.0f 3 APPENDIX D L
AVERAGE DAILY POWER LEVEL DOCKET NO. 050-0261 UNIT ROBINSON UNIT 2 DATE 08/01/84 COMPLETED BY A.
E. SCOTT TELEPHONE (803)303-4524 DULY 1984
@AY AVG. DAILY POWER LEVEL DAY AVG. DAILY POWER LEVEL (MWE-NET)
(MWE-NET) i
~2 17
-2 2
-2 18
-2 3
-2 19
-2 4
-2 20
-2 5
-2 21
-2 6
-2 22
-2 7
-2 23
-2 0
-2 24
-?
9
-2 25
-2 00
-2 26
-2 Oi
-2 27
-2 92
-2 20
-2 03
-2 29
-2 14
-2 30
-2 05
-2 31
-2, 06
-2 i
/
1.16 - 0
_=v Enclosure to Sericia RSEP/84-519 Page 3 cf 3
'050-0261
~
DOCKET NO.
UNIT SHUTDOWNS AND POWER REDUCTIONS H. B. Robinsbtl UNIT NAME DATE 840A01 COMPLETED BY A.
F_
hner REPORT MONTy July TELEPHONE (R03)383-4524 i
. =
C T
a e
f.sosa Licensee
,E t, En, cause & Corrective
.5 E F
h Action to No.
Date g
3g g
_g g y Event s 'T
$, E 5
jig Report #
80
}'
Prevent Recurrence c5 P
0701-840701 S
744 C
1 CJ HTEXCH Continuation of Refueling and Steam Generator Replacement Outage.
I 2
3 4
F: Forced Reason:
Method:
Exhibit G-Instructiims S: Scheduled A-Equip.nent Failure (Explain) 1-Manual for Preparation of Data B-Maintenance of Test 2-Manual Scrarn-Entr) Sheets for Licensee C-Refueiing 3-Automatic Scram.
Event Report (LER) File (NUREG-D-Regulatory Restriction 4-Other ( Explain) 0161)
E-Operator Training & License Examination F-Admmistrative 5
G-Operational Error (Explain)
Exhibit I Same Source-(9/77)
Il-Other (Explain) l I
Jc:cr
' ~
- .y
^
^
Carolina Power & Light Company H. B. ROBINSON STEAM ELECTRIC PLANT POST OFFICE BOX 790 HARTSVILLE, SOUTH CAROLINA 29550 AUG 9 384 Robinson File No: 15505 Serial:
RSEP/84-519 Mr. Richard C. DeYoung, Director Office of Inspection & Enforcement-U. S. Nuclear Regulatory Commission Washington, D. C.
20555 H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 DOCKET No. 50-261 LICENSE NO. DPR-23 MONTHLY OPERATIONS REPORT
Dear Mr. DeYoung:
In accordance with Technical Specification 6.9.1.c for the H. B. Robinson Steam Electric Plant, Unit No. 2, Carolina Power and Light Company herewith submits the report of operation statistics and shutdown experience for the
. month of July, 1984.
Very truly yours, W
R. E. Margan General Manager H. B. Robinson SEC Plant i
AES/ml Enclosure cc:
R. A. Hartfield (2)
J. P. O'Reilly (1) b, I
l
,