IE Insp Repts 50-266/83-08 & 50-301/83-08 on 830509-11 & 0609.Noncompliance Noted:Failure to Collect Air Samples on 830331 During Reactor Vessel Head Removal & Cavity Flood Operations & to Install SA-11 Main Steam Line MonitorsML20076K649 |
Person / Time |
---|
Site: |
Point Beach |
---|
Issue date: |
06/30/1983 |
---|
From: |
Greger L, Lovendale P, Miller D NRC Office of Inspection & Enforcement (IE Region III) |
---|
To: |
|
---|
Shared Package |
---|
ML20076K643 |
List: |
---|
References |
---|
RTR-NUREG-0737, RTR-NUREG-737, TASK-2.F.1, TASK-TM, NRC-2020-000157 50-266-83-08, 50-266-83-8, 50-301-83-08, 50-301-83-8, NUDOCS 8307180047 |
Download: ML20076K649 (8) |
|
|
---|
Category:INSPECTION REPORT
MONTHYEARIR 05000266/19990151999-09-30030 September 1999 Insp Repts 50-266/99-15 & 50-301/99-15 on 990830-0903.No Violations Noted.Major Areas Inspected:Operations & Training IR 05000266/19990131999-09-29029 September 1999 Insp Repts 50-266/99-13 & 50-301/99-13 on 990714-0830.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000266/19990141999-08-31031 August 1999 Insp Repts 50-266/99-14 & 50-301/99-14 on 990726-30.No Violations Noted.Major Areas Inspected:Access Authorization Program,Alarm Stations & Communications.Security Mgt Also Inspected IR 05000266/19990091999-07-28028 July 1999 Insp Repts 50-266/99-09 & 50-301/99-09 on 990528-0713. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support IR 05000266/19990121999-07-14014 July 1999 Insp Repts 50-266/99-12 & 50-301/99-12 on 990614-18.No Violations Noted.Major Areas Inspected:Implementation of Inservice Test Program & MOVs Capability,Per GL 96-05 IR 05000266/19990081999-06-18018 June 1999 Insp Repts 50-266/99-08 & 50-301/99-08 on 990411-0527.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000266/19990061999-05-0707 May 1999 Insp Repts 50-266/99-06 & 50-301/99-06 on 990223-0410. Non-cited Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000266/19990051999-04-20020 April 1999 Insp Repts 50-266/99-05 & 50-301/99-05 on 990222-0312. Violations Noted.Major Areas Inspected:Effectiveness & Engineering & Technical Support Organization in Performance of Routine & Reactive Site Activities & Problem Prevention IR 05000266/19990101999-04-19019 April 1999 Insp Repts 50-266/99-10 & 50-301/99-10 on 990329-0401.No Violations Noted.Major Areas Inspected:Review of Emergency Preparedness Program & Aspect of Plant Support IR 05000266/19990071999-03-16016 March 1999 Insp Repts 50-266/99-07 & 50-301/99-07 on 990216-19.No Violations Noted.Major Areas Inspected:Routine Insp of Radiation Protection & Chemistry Program Which Included Water Chemistry Control Program ML20204D8311999-03-12012 March 1999 Insp Rept 50-266/99-04 on 990105-0222.One Violations of NRC Requirements Occurred & Being Treated as non-cited Violation.Major Areas Inspected:Operations,Maint & Engineering IR 05000266/19990021999-03-10010 March 1999 Insp Repts 50-266/99-02 & 50-301/99-02 on 990105-0222. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support IR 05000266/19990031999-02-0101 February 1999 Insp Repts 50-266/99-03 & 50-301/99-03 on 990111-15.No Violations Noted.Major Areas Inspected:Review of Plant Support Activities Relating to Physical Protection of Facility IR 05000266/19980211999-01-15015 January 1999 Insp Repts 50-266/98-21 & 50-301/98-21 on 981121-990104. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000266/19980221998-12-24024 December 1998 Insp Repts 50-266/98-22 & 50-301/98-22 on 981208-10.No Violations Noted.Major Areas Inspected:Maint Rule Program IR 05000206/19980191998-12-0404 December 1998 Insp Repts 50-206/98-19 & 50-301/98-19 on 981004.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000266/19980201998-11-30030 November 1998 Insp Rept 50-266/98-20 & 50-301/98-20 on 981102-06.No Violations Noted.Major Areas Inspected:Plant Biennial Exercise of Emergency Plan IR 05000266/19980171998-10-26026 October 1998 Insp Repts 50-266/98-17 & 50-301/98-17 on 980818-1005.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000266/19980181998-10-0202 October 1998 Insp Repts 50-266/98-18 & 50-301/98-18 on 980831-0904.No Violations Noted.Major Areas Inspected:Radiation Protection Program,Including Review of Whole Body Counter Calibration, Portable Instrument Calibration & Routine Contamination IR 05000266/19980151998-09-11011 September 1998 Insp Repts 50-266/98-15 & 50-301/98-15 on 980720-31.No Violations Noted.Major Areas Inspected:Adequacy of Licensee Programs,Procedures,Training & Supporting Documentation to Ensure TS Required Surveillance Testing IR 05000266/19980131998-09-11011 September 1998 Insp Repts 50-266/98-13 & 50-301/98-13 on 980608-12 & 0715-16.Violations Noted.Major Areas Inspected:Adequacy of Licensee Programs,Procedures,Training,Equipment & Supporting Documentation for Maint of Medium Voltage & Low Voltage IR 05000266/19980141998-09-0303 September 1998 Insp Repts 50-266/98-14 & 50-301/98-14 on 980707-0817.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000266/19980161998-08-10010 August 1998 Insp Repts 50-266/98-16 & 50-301/98-16 on 980713-17.No Violations Noted.Major Areas Inspected:Review of Plant Support Activities Re Physical Protection of Facility ML20236V6621998-07-29029 July 1998 Insp Repts 50-266/98-11 & 50-301/98-11 on 980526-0706. No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000266/19980091998-06-19019 June 1998 Insp Repts 50-266/98-09 & 50-301/98-09 on 980414-0523. Violation Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000266/19980121998-06-11011 June 1998 Insp Repts 50-266/98-12 & 50-301/98-12 on 980518-22. Violations Noted.Major Areas Inspected:Review of Unit 1 Refueling Outage Doses,Solid Radwaste Mgt,Transportation of Radioactive Matls & Health Physics Program IR 05000266/19980071998-06-0303 June 1998 Insp Rept 50-266/98-07 on 980310-13,16,17,0401-02,22,24 & 0504-05.No Violations Noted.Major Areas Inspected: Maint & Engineeing IR 05000301/19980051998-05-0505 May 1998 Insp Rept 50-301/98-05 on 971216-980309.Violations Noted. Major Areas Inspected:Maint ML20247D2961998-05-0505 May 1998 Insp Repts 50-266/98-06 & 50-301/98-06 on 980303-0413. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000266/19980081998-04-15015 April 1998 Insp Repts 50-266/98-08 & 50-301/98-08 on 980316-20.No Violations Noted.Major Areas Inspected:Radiation Protection Performance During Refueling Outage ML20217J4571998-04-0101 April 1998 Insp Repts 50-266/98-10 & 50-301/98-10 on 980310-18. Violations Noted.Major Areas Inspected:Review of Measuring & Test Equipment Procedures ML20217D3531998-03-21021 March 1998 Insp Repts 50-266/98-03 & 50-301/98-03 on 980120-0302. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000266/19980041998-02-27027 February 1998 Insp Repts 50-266/98-04 & 50-301/98-04 on 980202-06.No Violations Noted.Major Areas Inspected:Review of Health Physics Dept Preparations for Unit 1 Refueling Outage, Including ALARA Planning & Work Planning ML20203D4361998-02-19019 February 1998 Insp Repts 50-266/97-23 & 50-301/97-23 on 971020-1107. Violations Noted.Major Areas Inspected:Licensee Controls in Area of SEs as Well as Effectiveness of Licensee Controls in Identifying,Resolving & Correcting Problems IR 05000266/19970221998-02-18018 February 1998 Insp Repts 50-266/97-22 & 50-301/97-22 on 971104-980203.No Violations Noted.Major Areas Inspected:Review of 20 Licensee Event Repts Submitted Between 960909 & 971215 ML20202E9811998-02-10010 February 1998 Insp Repts 50-266/97-26 & 50-301/97-26 on 971201-980120. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20202E3841998-02-0909 February 1998 Partially Withheld Insp Repts 50-266/98-02 & 50-301/98-02 on 980105-20 (Ref 10CFR73.71).Violations Noted.Major Areas Inspected:Review of Plant Support Activities Re Physical Protection of Facility ML20199F1361997-12-22022 December 1997 Insp Repts 50-266/97-21 & 50-301/97-21 on 971021-1130. Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000266/19970191997-11-14014 November 1997 Insp Repts 50-266/97-19 & 50-301/97-19 on 970908-12.Noncited Violations Noted.Major Areas Inspected:Review of Licensee Licensed RO & SRO Requalification Training Programs IR 05000266/19970151997-10-14014 October 1997 Insp Repts 50-266/97-15 & 50-301/97-15 on 970707-11. Violations Noted.Major Areas Inspected:Fire Protection Program & Several App R Issues IR 05000266/19970181997-10-0404 October 1997 Insp Repts 50-266/97-18 & 50-301/97-18 on 970825-29. Violations Noted.Major Areas Inspected:Self Reading Dosimeter Calibrations,Radiation Work Permit Program, Condition Reporting Sys & Health Physics Organization ML20211B1961997-09-17017 September 1997 Insp Repts 50-266/97-17 & 50-301/97-17 on 970304-0805. Violations Noted.Major Areas Inspected:Operations & Maint IR 05000266/19970101997-09-15015 September 1997 Insp Repts 50-266/97-10 & 50-301/97-10 on 970519-0613. Violations Noted.Major Areas Inspected:Maint,Operations & Engineering Support IR 05000266/19970121997-08-14014 August 1997 Emergency Preparedness Insp Repts 50-266/97-12 & 50-301/97-12 on 970623-27.No Violations Noted.Major Areas Inpected:Ep Program ML20151K4271997-07-29029 July 1997 Insp Repts 50-266/97-14 & 50-301/97-14 on 970707-11. Violations Noted.Major Areas Inspected:Review of Radiological Environ Monitoring Program,Water Chemistry Control Program & Health Physics Insp ML20148L4451997-06-0909 June 1997 Insp Repts 50-266/97-08 & 50-301/97-08 on 970505-09. Violations Noted.Major Areas Inspected:Review of High Radiation Area Controls,Solid Radwaste Program, Transportation of Radwaste & Radiation Protection Program ML20138K2111997-05-0505 May 1997 Partially Withheld Insp Repts 50-266/97-07 & 50-301/97-07 on 970331-0410 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Review of Plant Support Activities Re Physical Protection of Facility & Security Performance IR 05000266/19970021997-04-25025 April 1997 Insp Repts 50-266/97-02 & 50-301/97-02 on 970113-0304.No Violations Noted.Major Areas Inspected:Preliminary Review of Portions of Operability Evaluation of CFCs & Tscr 192 IR 05000266/19970041997-04-0303 April 1997 Insp Repts 50-266/97-04 & 50-301/97-04 on 970303-07. Violations Noted.Major Areas Inspected:Review of High Radiation Area Controls,Liquid Effluent Program & Observation of Radiological Work & Review of SG Replacement IR 05000266/19970051997-04-0303 April 1997 Insp Repts 50-266/97-05 & 50-301/97-05 on 970208-0314.No Violations Noted.Major Areas Inspected:Insp to Review Use of Manual Operator Action in Place of Automatic Operation of Train a of MDAFW Sys During Accident 1999-09-30
[Table view] Category:NRC-GENERATED
MONTHYEARIR 05000266/19990151999-09-30030 September 1999 Insp Repts 50-266/99-15 & 50-301/99-15 on 990830-0903.No Violations Noted.Major Areas Inspected:Operations & Training IR 05000266/19990131999-09-29029 September 1999 Insp Repts 50-266/99-13 & 50-301/99-13 on 990714-0830.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000266/19990141999-08-31031 August 1999 Insp Repts 50-266/99-14 & 50-301/99-14 on 990726-30.No Violations Noted.Major Areas Inspected:Access Authorization Program,Alarm Stations & Communications.Security Mgt Also Inspected IR 05000266/19990091999-07-28028 July 1999 Insp Repts 50-266/99-09 & 50-301/99-09 on 990528-0713. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support IR 05000266/19990121999-07-14014 July 1999 Insp Repts 50-266/99-12 & 50-301/99-12 on 990614-18.No Violations Noted.Major Areas Inspected:Implementation of Inservice Test Program & MOVs Capability,Per GL 96-05 IR 05000266/19990081999-06-18018 June 1999 Insp Repts 50-266/99-08 & 50-301/99-08 on 990411-0527.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000266/19990061999-05-0707 May 1999 Insp Repts 50-266/99-06 & 50-301/99-06 on 990223-0410. Non-cited Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000266/19990051999-04-20020 April 1999 Insp Repts 50-266/99-05 & 50-301/99-05 on 990222-0312. Violations Noted.Major Areas Inspected:Effectiveness & Engineering & Technical Support Organization in Performance of Routine & Reactive Site Activities & Problem Prevention IR 05000266/19990101999-04-19019 April 1999 Insp Repts 50-266/99-10 & 50-301/99-10 on 990329-0401.No Violations Noted.Major Areas Inspected:Review of Emergency Preparedness Program & Aspect of Plant Support IR 05000266/19990071999-03-16016 March 1999 Insp Repts 50-266/99-07 & 50-301/99-07 on 990216-19.No Violations Noted.Major Areas Inspected:Routine Insp of Radiation Protection & Chemistry Program Which Included Water Chemistry Control Program ML20204D8311999-03-12012 March 1999 Insp Rept 50-266/99-04 on 990105-0222.One Violations of NRC Requirements Occurred & Being Treated as non-cited Violation.Major Areas Inspected:Operations,Maint & Engineering IR 05000266/19990021999-03-10010 March 1999 Insp Repts 50-266/99-02 & 50-301/99-02 on 990105-0222. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support IR 05000266/19990031999-02-0101 February 1999 Insp Repts 50-266/99-03 & 50-301/99-03 on 990111-15.No Violations Noted.Major Areas Inspected:Review of Plant Support Activities Relating to Physical Protection of Facility IR 05000266/19980211999-01-15015 January 1999 Insp Repts 50-266/98-21 & 50-301/98-21 on 981121-990104. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000266/19980221998-12-24024 December 1998 Insp Repts 50-266/98-22 & 50-301/98-22 on 981208-10.No Violations Noted.Major Areas Inspected:Maint Rule Program IR 05000206/19980191998-12-0404 December 1998 Insp Repts 50-206/98-19 & 50-301/98-19 on 981004.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000266/19980201998-11-30030 November 1998 Insp Rept 50-266/98-20 & 50-301/98-20 on 981102-06.No Violations Noted.Major Areas Inspected:Plant Biennial Exercise of Emergency Plan IR 05000266/19980171998-10-26026 October 1998 Insp Repts 50-266/98-17 & 50-301/98-17 on 980818-1005.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000266/19980181998-10-0202 October 1998 Insp Repts 50-266/98-18 & 50-301/98-18 on 980831-0904.No Violations Noted.Major Areas Inspected:Radiation Protection Program,Including Review of Whole Body Counter Calibration, Portable Instrument Calibration & Routine Contamination IR 05000266/19980151998-09-11011 September 1998 Insp Repts 50-266/98-15 & 50-301/98-15 on 980720-31.No Violations Noted.Major Areas Inspected:Adequacy of Licensee Programs,Procedures,Training & Supporting Documentation to Ensure TS Required Surveillance Testing IR 05000266/19980131998-09-11011 September 1998 Insp Repts 50-266/98-13 & 50-301/98-13 on 980608-12 & 0715-16.Violations Noted.Major Areas Inspected:Adequacy of Licensee Programs,Procedures,Training,Equipment & Supporting Documentation for Maint of Medium Voltage & Low Voltage IR 05000266/19980141998-09-0303 September 1998 Insp Repts 50-266/98-14 & 50-301/98-14 on 980707-0817.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000266/19980161998-08-10010 August 1998 Insp Repts 50-266/98-16 & 50-301/98-16 on 980713-17.No Violations Noted.Major Areas Inspected:Review of Plant Support Activities Re Physical Protection of Facility ML20236V6621998-07-29029 July 1998 Insp Repts 50-266/98-11 & 50-301/98-11 on 980526-0706. No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000266/19980091998-06-19019 June 1998 Insp Repts 50-266/98-09 & 50-301/98-09 on 980414-0523. Violation Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000266/19980121998-06-11011 June 1998 Insp Repts 50-266/98-12 & 50-301/98-12 on 980518-22. Violations Noted.Major Areas Inspected:Review of Unit 1 Refueling Outage Doses,Solid Radwaste Mgt,Transportation of Radioactive Matls & Health Physics Program IR 05000266/19980071998-06-0303 June 1998 Insp Rept 50-266/98-07 on 980310-13,16,17,0401-02,22,24 & 0504-05.No Violations Noted.Major Areas Inspected: Maint & Engineeing IR 05000301/19980051998-05-0505 May 1998 Insp Rept 50-301/98-05 on 971216-980309.Violations Noted. Major Areas Inspected:Maint ML20247D2961998-05-0505 May 1998 Insp Repts 50-266/98-06 & 50-301/98-06 on 980303-0413. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000266/19980081998-04-15015 April 1998 Insp Repts 50-266/98-08 & 50-301/98-08 on 980316-20.No Violations Noted.Major Areas Inspected:Radiation Protection Performance During Refueling Outage ML20217J4571998-04-0101 April 1998 Insp Repts 50-266/98-10 & 50-301/98-10 on 980310-18. Violations Noted.Major Areas Inspected:Review of Measuring & Test Equipment Procedures ML20217D3531998-03-21021 March 1998 Insp Repts 50-266/98-03 & 50-301/98-03 on 980120-0302. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000266/19980041998-02-27027 February 1998 Insp Repts 50-266/98-04 & 50-301/98-04 on 980202-06.No Violations Noted.Major Areas Inspected:Review of Health Physics Dept Preparations for Unit 1 Refueling Outage, Including ALARA Planning & Work Planning ML20203D4361998-02-19019 February 1998 Insp Repts 50-266/97-23 & 50-301/97-23 on 971020-1107. Violations Noted.Major Areas Inspected:Licensee Controls in Area of SEs as Well as Effectiveness of Licensee Controls in Identifying,Resolving & Correcting Problems IR 05000266/19970221998-02-18018 February 1998 Insp Repts 50-266/97-22 & 50-301/97-22 on 971104-980203.No Violations Noted.Major Areas Inspected:Review of 20 Licensee Event Repts Submitted Between 960909 & 971215 ML20202E9811998-02-10010 February 1998 Insp Repts 50-266/97-26 & 50-301/97-26 on 971201-980120. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20202E3841998-02-0909 February 1998 Partially Withheld Insp Repts 50-266/98-02 & 50-301/98-02 on 980105-20 (Ref 10CFR73.71).Violations Noted.Major Areas Inspected:Review of Plant Support Activities Re Physical Protection of Facility ML20199F1361997-12-22022 December 1997 Insp Repts 50-266/97-21 & 50-301/97-21 on 971021-1130. Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000266/19970191997-11-14014 November 1997 Insp Repts 50-266/97-19 & 50-301/97-19 on 970908-12.Noncited Violations Noted.Major Areas Inspected:Review of Licensee Licensed RO & SRO Requalification Training Programs IR 05000266/19970151997-10-14014 October 1997 Insp Repts 50-266/97-15 & 50-301/97-15 on 970707-11. Violations Noted.Major Areas Inspected:Fire Protection Program & Several App R Issues IR 05000266/19970181997-10-0404 October 1997 Insp Repts 50-266/97-18 & 50-301/97-18 on 970825-29. Violations Noted.Major Areas Inspected:Self Reading Dosimeter Calibrations,Radiation Work Permit Program, Condition Reporting Sys & Health Physics Organization ML20211B1961997-09-17017 September 1997 Insp Repts 50-266/97-17 & 50-301/97-17 on 970304-0805. Violations Noted.Major Areas Inspected:Operations & Maint IR 05000266/19970101997-09-15015 September 1997 Insp Repts 50-266/97-10 & 50-301/97-10 on 970519-0613. Violations Noted.Major Areas Inspected:Maint,Operations & Engineering Support IR 05000266/19970121997-08-14014 August 1997 Emergency Preparedness Insp Repts 50-266/97-12 & 50-301/97-12 on 970623-27.No Violations Noted.Major Areas Inpected:Ep Program ML20151K4271997-07-29029 July 1997 Insp Repts 50-266/97-14 & 50-301/97-14 on 970707-11. Violations Noted.Major Areas Inspected:Review of Radiological Environ Monitoring Program,Water Chemistry Control Program & Health Physics Insp ML20148L4451997-06-0909 June 1997 Insp Repts 50-266/97-08 & 50-301/97-08 on 970505-09. Violations Noted.Major Areas Inspected:Review of High Radiation Area Controls,Solid Radwaste Program, Transportation of Radwaste & Radiation Protection Program ML20138K2111997-05-0505 May 1997 Partially Withheld Insp Repts 50-266/97-07 & 50-301/97-07 on 970331-0410 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Review of Plant Support Activities Re Physical Protection of Facility & Security Performance IR 05000266/19970021997-04-25025 April 1997 Insp Repts 50-266/97-02 & 50-301/97-02 on 970113-0304.No Violations Noted.Major Areas Inspected:Preliminary Review of Portions of Operability Evaluation of CFCs & Tscr 192 IR 05000266/19970041997-04-0303 April 1997 Insp Repts 50-266/97-04 & 50-301/97-04 on 970303-07. Violations Noted.Major Areas Inspected:Review of High Radiation Area Controls,Liquid Effluent Program & Observation of Radiological Work & Review of SG Replacement IR 05000266/19970051997-04-0303 April 1997 Insp Repts 50-266/97-05 & 50-301/97-05 on 970208-0314.No Violations Noted.Major Areas Inspected:Insp to Review Use of Manual Operator Action in Place of Automatic Operation of Train a of MDAFW Sys During Accident 1999-09-30
[Table view] Category:INSPECTION REPORT
MONTHYEARIR 05000266/19990151999-09-30030 September 1999 Insp Repts 50-266/99-15 & 50-301/99-15 on 990830-0903.No Violations Noted.Major Areas Inspected:Operations & Training IR 05000266/19990131999-09-29029 September 1999 Insp Repts 50-266/99-13 & 50-301/99-13 on 990714-0830.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000266/19990141999-08-31031 August 1999 Insp Repts 50-266/99-14 & 50-301/99-14 on 990726-30.No Violations Noted.Major Areas Inspected:Access Authorization Program,Alarm Stations & Communications.Security Mgt Also Inspected IR 05000266/19990091999-07-28028 July 1999 Insp Repts 50-266/99-09 & 50-301/99-09 on 990528-0713. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support IR 05000266/19990121999-07-14014 July 1999 Insp Repts 50-266/99-12 & 50-301/99-12 on 990614-18.No Violations Noted.Major Areas Inspected:Implementation of Inservice Test Program & MOVs Capability,Per GL 96-05 IR 05000266/19990081999-06-18018 June 1999 Insp Repts 50-266/99-08 & 50-301/99-08 on 990411-0527.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000266/19990061999-05-0707 May 1999 Insp Repts 50-266/99-06 & 50-301/99-06 on 990223-0410. Non-cited Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000266/19990051999-04-20020 April 1999 Insp Repts 50-266/99-05 & 50-301/99-05 on 990222-0312. Violations Noted.Major Areas Inspected:Effectiveness & Engineering & Technical Support Organization in Performance of Routine & Reactive Site Activities & Problem Prevention IR 05000266/19990101999-04-19019 April 1999 Insp Repts 50-266/99-10 & 50-301/99-10 on 990329-0401.No Violations Noted.Major Areas Inspected:Review of Emergency Preparedness Program & Aspect of Plant Support IR 05000266/19990071999-03-16016 March 1999 Insp Repts 50-266/99-07 & 50-301/99-07 on 990216-19.No Violations Noted.Major Areas Inspected:Routine Insp of Radiation Protection & Chemistry Program Which Included Water Chemistry Control Program ML20204D8311999-03-12012 March 1999 Insp Rept 50-266/99-04 on 990105-0222.One Violations of NRC Requirements Occurred & Being Treated as non-cited Violation.Major Areas Inspected:Operations,Maint & Engineering IR 05000266/19990021999-03-10010 March 1999 Insp Repts 50-266/99-02 & 50-301/99-02 on 990105-0222. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support IR 05000266/19990031999-02-0101 February 1999 Insp Repts 50-266/99-03 & 50-301/99-03 on 990111-15.No Violations Noted.Major Areas Inspected:Review of Plant Support Activities Relating to Physical Protection of Facility IR 05000266/19980211999-01-15015 January 1999 Insp Repts 50-266/98-21 & 50-301/98-21 on 981121-990104. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000266/19980221998-12-24024 December 1998 Insp Repts 50-266/98-22 & 50-301/98-22 on 981208-10.No Violations Noted.Major Areas Inspected:Maint Rule Program IR 05000206/19980191998-12-0404 December 1998 Insp Repts 50-206/98-19 & 50-301/98-19 on 981004.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000266/19980201998-11-30030 November 1998 Insp Rept 50-266/98-20 & 50-301/98-20 on 981102-06.No Violations Noted.Major Areas Inspected:Plant Biennial Exercise of Emergency Plan IR 05000266/19980171998-10-26026 October 1998 Insp Repts 50-266/98-17 & 50-301/98-17 on 980818-1005.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000266/19980181998-10-0202 October 1998 Insp Repts 50-266/98-18 & 50-301/98-18 on 980831-0904.No Violations Noted.Major Areas Inspected:Radiation Protection Program,Including Review of Whole Body Counter Calibration, Portable Instrument Calibration & Routine Contamination IR 05000266/19980151998-09-11011 September 1998 Insp Repts 50-266/98-15 & 50-301/98-15 on 980720-31.No Violations Noted.Major Areas Inspected:Adequacy of Licensee Programs,Procedures,Training & Supporting Documentation to Ensure TS Required Surveillance Testing IR 05000266/19980131998-09-11011 September 1998 Insp Repts 50-266/98-13 & 50-301/98-13 on 980608-12 & 0715-16.Violations Noted.Major Areas Inspected:Adequacy of Licensee Programs,Procedures,Training,Equipment & Supporting Documentation for Maint of Medium Voltage & Low Voltage IR 05000266/19980141998-09-0303 September 1998 Insp Repts 50-266/98-14 & 50-301/98-14 on 980707-0817.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000266/19980161998-08-10010 August 1998 Insp Repts 50-266/98-16 & 50-301/98-16 on 980713-17.No Violations Noted.Major Areas Inspected:Review of Plant Support Activities Re Physical Protection of Facility ML20236V6621998-07-29029 July 1998 Insp Repts 50-266/98-11 & 50-301/98-11 on 980526-0706. No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000266/19980091998-06-19019 June 1998 Insp Repts 50-266/98-09 & 50-301/98-09 on 980414-0523. Violation Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000266/19980121998-06-11011 June 1998 Insp Repts 50-266/98-12 & 50-301/98-12 on 980518-22. Violations Noted.Major Areas Inspected:Review of Unit 1 Refueling Outage Doses,Solid Radwaste Mgt,Transportation of Radioactive Matls & Health Physics Program IR 05000266/19980071998-06-0303 June 1998 Insp Rept 50-266/98-07 on 980310-13,16,17,0401-02,22,24 & 0504-05.No Violations Noted.Major Areas Inspected: Maint & Engineeing IR 05000301/19980051998-05-0505 May 1998 Insp Rept 50-301/98-05 on 971216-980309.Violations Noted. Major Areas Inspected:Maint ML20247D2961998-05-0505 May 1998 Insp Repts 50-266/98-06 & 50-301/98-06 on 980303-0413. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000266/19980081998-04-15015 April 1998 Insp Repts 50-266/98-08 & 50-301/98-08 on 980316-20.No Violations Noted.Major Areas Inspected:Radiation Protection Performance During Refueling Outage ML20217J4571998-04-0101 April 1998 Insp Repts 50-266/98-10 & 50-301/98-10 on 980310-18. Violations Noted.Major Areas Inspected:Review of Measuring & Test Equipment Procedures ML20217D3531998-03-21021 March 1998 Insp Repts 50-266/98-03 & 50-301/98-03 on 980120-0302. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000266/19980041998-02-27027 February 1998 Insp Repts 50-266/98-04 & 50-301/98-04 on 980202-06.No Violations Noted.Major Areas Inspected:Review of Health Physics Dept Preparations for Unit 1 Refueling Outage, Including ALARA Planning & Work Planning ML20203D4361998-02-19019 February 1998 Insp Repts 50-266/97-23 & 50-301/97-23 on 971020-1107. Violations Noted.Major Areas Inspected:Licensee Controls in Area of SEs as Well as Effectiveness of Licensee Controls in Identifying,Resolving & Correcting Problems IR 05000266/19970221998-02-18018 February 1998 Insp Repts 50-266/97-22 & 50-301/97-22 on 971104-980203.No Violations Noted.Major Areas Inspected:Review of 20 Licensee Event Repts Submitted Between 960909 & 971215 ML20202E9811998-02-10010 February 1998 Insp Repts 50-266/97-26 & 50-301/97-26 on 971201-980120. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20202E3841998-02-0909 February 1998 Partially Withheld Insp Repts 50-266/98-02 & 50-301/98-02 on 980105-20 (Ref 10CFR73.71).Violations Noted.Major Areas Inspected:Review of Plant Support Activities Re Physical Protection of Facility ML20199F1361997-12-22022 December 1997 Insp Repts 50-266/97-21 & 50-301/97-21 on 971021-1130. Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000266/19970191997-11-14014 November 1997 Insp Repts 50-266/97-19 & 50-301/97-19 on 970908-12.Noncited Violations Noted.Major Areas Inspected:Review of Licensee Licensed RO & SRO Requalification Training Programs IR 05000266/19970151997-10-14014 October 1997 Insp Repts 50-266/97-15 & 50-301/97-15 on 970707-11. Violations Noted.Major Areas Inspected:Fire Protection Program & Several App R Issues IR 05000266/19970181997-10-0404 October 1997 Insp Repts 50-266/97-18 & 50-301/97-18 on 970825-29. Violations Noted.Major Areas Inspected:Self Reading Dosimeter Calibrations,Radiation Work Permit Program, Condition Reporting Sys & Health Physics Organization ML20211B1961997-09-17017 September 1997 Insp Repts 50-266/97-17 & 50-301/97-17 on 970304-0805. Violations Noted.Major Areas Inspected:Operations & Maint IR 05000266/19970101997-09-15015 September 1997 Insp Repts 50-266/97-10 & 50-301/97-10 on 970519-0613. Violations Noted.Major Areas Inspected:Maint,Operations & Engineering Support IR 05000266/19970121997-08-14014 August 1997 Emergency Preparedness Insp Repts 50-266/97-12 & 50-301/97-12 on 970623-27.No Violations Noted.Major Areas Inpected:Ep Program ML20151K4271997-07-29029 July 1997 Insp Repts 50-266/97-14 & 50-301/97-14 on 970707-11. Violations Noted.Major Areas Inspected:Review of Radiological Environ Monitoring Program,Water Chemistry Control Program & Health Physics Insp ML20148L4451997-06-0909 June 1997 Insp Repts 50-266/97-08 & 50-301/97-08 on 970505-09. Violations Noted.Major Areas Inspected:Review of High Radiation Area Controls,Solid Radwaste Program, Transportation of Radwaste & Radiation Protection Program ML20138K2111997-05-0505 May 1997 Partially Withheld Insp Repts 50-266/97-07 & 50-301/97-07 on 970331-0410 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Review of Plant Support Activities Re Physical Protection of Facility & Security Performance IR 05000266/19970021997-04-25025 April 1997 Insp Repts 50-266/97-02 & 50-301/97-02 on 970113-0304.No Violations Noted.Major Areas Inspected:Preliminary Review of Portions of Operability Evaluation of CFCs & Tscr 192 IR 05000266/19970041997-04-0303 April 1997 Insp Repts 50-266/97-04 & 50-301/97-04 on 970303-07. Violations Noted.Major Areas Inspected:Review of High Radiation Area Controls,Liquid Effluent Program & Observation of Radiological Work & Review of SG Replacement IR 05000266/19970051997-04-0303 April 1997 Insp Repts 50-266/97-05 & 50-301/97-05 on 970208-0314.No Violations Noted.Major Areas Inspected:Insp to Review Use of Manual Operator Action in Place of Automatic Operation of Train a of MDAFW Sys During Accident 1999-09-30
[Table view] Category:UTILITY
MONTHYEARIR 05000266/19900191990-10-30030 October 1990 Insp Repts 50-266/90-19 & 50-301/90-19 on 900905-1015. Violation Noted.Major Areas Inspected:Operational Safety, Radiological Controls,Maint & Surveillance,Emergency Preparedness,Security,Technical Support & Safety Assessment IR 05000266/19900211990-10-11011 October 1990 Enforcement Conference Repts 50-266/90-21 & 50-301/90-21 on 901004 Re Violation of 10CFR50,App B, Design Control IR 05000266/19900181990-09-24024 September 1990 Insp Repts 50-266/90-18 & 50-301/90-18 on 900820-24. Violations Noted.Major Areas Inspected:Followup of Previously Identified Electrical Distribution Safety Functional Insp Deficiencies IR 05000266/19900171990-08-20020 August 1990 Insp Repts 50-266/90-17 & 50-301/90-17 on 900813-17.No Violations,Deficiencies or Deviations Noted.Major Areas Inspected:Emergency Preparedness Program & Licensee Action on Previously Identified Items IR 05000266/19900141990-08-10010 August 1990 Insp Repts 50-266/90-14 & 50-301/90-14 on 900616-0731.No Violations or Deviations Noted.Major Areas Inspected:Maint & Surveillance,Emergency Preparedness,Security,Engineering & Technical Support IR 05000266/19900101990-06-26026 June 1990 Insp Repts 50-266/90-10 & 50-301/90-10 on 900501-0615.No Violations Noted.Major Areas Inspected:Operational Safety, Radiological Controls,Maint & Surveillance,Emergency Preparedness,Security & Engineering & Technical Support IR 05000266/19900121990-06-0808 June 1990 Enforcement Conference Repts 50-266/90-12 & 50-301/90-12 on 900525.Violations Noted.Major Areas Discussed:Licensee Apparent Recurrent High Radiation Area Barrier Violations & Weaknesses in Radiation Protection Program IR 05000266/19890241989-09-14014 September 1989 Insp Repts 50-266/89-24 & 50-301/89-23 on 890716-0831.No Violations Noted.Major Areas Inspected:Operational Safety, Radiological Controls,Maint & Surveillance,Emergency Preparedness,Security & Engineering & Technical Support IR 05000266/19890261989-09-13013 September 1989 Insp Repts 50-266/89-26 & 50-301/89-25 on 890828-0901.No Violations or Deviations Noted.Major Areas Inspected:Onsite Followup of Events & Licensee Implementation of ATWS Rule 10CFR50.62 IR 05000266/19890221989-08-29029 August 1989 Insp Repts 50-266/89-22 & 50-301/89-21 on 890725-0824. Violations Noted.Major Areas Inspected:Radiation Protection Program,Organization & Mgt Controls,Staffing,External & Internal Exposure Controls & Control of Radioactive Matls IR 05000266/19890231989-08-14014 August 1989 Insp Repts 50-266/89-23 & 50-301/89-22 on 890710-14 & 0803. No Violations,Deficiencies or Deviations Noted.Major Areas Inspected:Licensee Emergency Preparedness Program & Followup on Actual Emergency Plan Actuations IR 05000266/19890201989-07-25025 July 1989 Insp Repts 50-266/89-20 & 50-301/89-19 on 890601-0715.Some Issues Unresolved.Major Areas Inspected:Previous Insp Findings,Operational Safety Verification,Radiological Controls,Maint & Surveillance & Emergency Preparedness IR 05000266/19890151989-06-21021 June 1989 Insp Repts 50-266/89-15 & 50-301/89-14 on 890401-0531. Violation Noted.Major Areas Inspected:Previous Insp Findings,Operational Safety Verification,Radiological Controls,Maint & Surveillance & Emergency Preparedness IR 05000266/19890131989-06-20020 June 1989 Insp Repts 50-266/89-13 & 50-301/89-12 on 890522-25 & 0614. No Violations Noted.Major Areas Inspected:Emergency Preparedness Program,Actions on Previous Open Items, Activations of Emergency Plan & Training IR 05000266/19890121989-06-0606 June 1989 Insp Repts 50-266/89-12 & 50-301/89-11 on 890425-0512.No Violations Noted.Major Areas Inspected:Corrective Actions Initiated in self-initiated SSFI of Emergency Diesel Generator Sys IR 05000266/19890171989-05-25025 May 1989 Partially Withheld Physical Security Insp Repts 50-266/89-17 & 50-301/89-16 on 890509-12 (Ref 10CFR73.21).Noncompliance Noted Re Access Controls & Protection of Safeguards Info. Major Areas Inspected:Area Barriers & Alarm Stations IR 05000266/19890181989-05-18018 May 1989 Mgt Meeting Insp Repts 50-266/89-18 & 50-301/89-17 on 890510.Major Areas of Discussion:History & Corrective Measures for Several Recurring Barrier Violations/Problems Identified Over Last 3 Yrs IR 05000266/19890111989-05-16016 May 1989 Insp Rept 50-266/89-11 on 890322-0508.No Violations Noted. Major Areas Inspected:Inservice Insp Activities.Strengths: Mgt Support & Productive Personnel IR 05000266/19890141989-04-19019 April 1989 Partially Withheld Physical Security Insp Repts 50-266/89-14 & 50-301/89-13 on 890403-04 (Ref 10CFR73.21).Violation Noted Re Penetration of Vital Area Barrier.Major Areas Inspected: Security Events Re Vital Area Barrier Degradation IR 05000266/19890081989-04-13013 April 1989 Emergency Preparedness Exercise Repts 50-266/89-08 & 50-301/89-08 on 890314-16.No Violations Noted.Major Areas Inspected:Observations of Key Functions & Locations During Exercise IR 05000266/19890061989-04-13013 April 1989 Insp Repts 50-266/89-06 & 50-301/89-06 on 890130-0331.No Violations Noted.Major Areas Inspected:Previous Insp Findings,Operational Safety Verification,Radiological Controls,Maint,Security & Engineering & Technical Support IR 05000266/19890071989-03-14014 March 1989 Insp Repts 50-266/89-07 & 50-301/89-07 on 890206-21.No Violations Noted.Major Areas Inspected:Mgt Support,Protected & Vital Area Barriers,Access Control - Personnel,Packages & Vehicles,Alarm Stations & Communications IR 05000266/19890051989-03-0202 March 1989 Insp Repts 50-266/89-05 & 50-301/89-05 on 890130-0203. Violations of 10CFR50.59 Noted.Major Areas Inspected:Design Changes & Mods IR 05000266/19880191988-11-10010 November 1988 Partially Withheld Security Insp Repts 50-266/88-19 & 50-301/88-17 (Ref 10CFR73.21).Violations Noted.Major Areas Inspected:Security Plan & Implementing Procedures,Records & Repts & Physical Barriers - Vital Areas IR 05000266/19880221988-10-21021 October 1988 Insp Repts 50-266/88-22 & 50-301/88-20 on 880926-30. Violation & Weaknesses Noted.Major Areas Inspected:Liquid, Gaseous,Solid Radwaste Mgt & Transportation Programs. Programs for Controlling Radwastes Appear Effective IR 05000266/19880211988-10-0606 October 1988 Insp Repts 50-266/88-21 & 50-301/88-19 on 880912-16.No Violations Noted.Major Areas Inspected:Emergency Preparedness Exercise.Weakness Noted Re Failure to Declare General Emergency When Emergency Action Levels Reached IR 05000266/19880181988-09-0808 September 1988 Insp Repts 50-266/88-18 & 50-301/88-16 on 880815-19.No Violations Noted.Major Areas Inspected:Activities W/Respect to NRC Bulletin 85-003 & Suppl 1, Motor Operated Valve Common Mode Failures During Plant Transients Due To.. IR 05000266/19880171988-08-0303 August 1988 Insp Repts 50-266/88-17 & 50-301/88-15 on 880711-15.No Violations Noted.Major Areas Inspected:Chemistry Program, Including Procedures,Organization & Training,Reactor Sys Water Quality Control Programs & Qa/Qc Control Programs IR 05000266/19880121988-07-0707 July 1988 Insp Repts 50-266/88-12 & 50-301/88-11 on 880501-0630.No Violations Noted.Major Areas Inspected:Licensee Action on Previous Insp Findings,Operational Safety,Surveillance, Maint,Physical Security & Radiological Protection IR 05000266/19880151988-07-0606 July 1988 Safety Insp Repts 50-266/88-15 & 50-301/88-13 on 880606 & 23.No Violations or Deviations Noted.Major Areas Inspected:Licensee Action on IE Bulletin 79-14 IR 05000266/19880141988-06-29029 June 1988 Insp Rept 50-266/88-14 on 880613-17.No Violations or Deviations Noted.Major Areas Inspected:Control Rod Testing, Core Power Distribution Limits,Calibr of Nuclear Instrumentation Sys & Control Rod Worth Measurements IR 05000266/19880101988-05-27027 May 1988 Insp Rept 50-266/88-10 on 880412-14,19-21 & 0510-12.No Violations or Deviations Noted.Major Areas Inspected: Inservice Insp Activities Including Review of Program, Procedures & Observation of Work & Work Activities IR 05000266/19880111988-05-26026 May 1988 Insp Repts 50-266/88-11 & 50-301/88-10 on 880503-05. Violations Noted.Major Areas Inspected:Licensee Action on IE Bulletin 79-14 & Snubber Functional Testing & Surveillance IR 05000266/19880131988-05-19019 May 1988 Insp Repts 50-266/88-13 & 50-301/88-12 on 880418-22. Violations Noted.Major Areas Inspected:Organization & Implementation Controls,Changes in Organization,Personnel, Facilities,Equipment & Procedures & Planning & Preparation IR 05000266/19880091988-05-16016 May 1988 Insp Repts 50-266/88-09 & 50-301/88-09 on 880316-0430. Violations Noted.Major Areas Inspected:Licensee Action on Previous Insp Findings,Operational Safety,Maint,Physical Security,Surveillance & Radiological Protection ML20151K0961988-04-11011 April 1988 Partially Withheld Insp Repts 50-266/88-08 & 50-301/88-08 on 880321-31 (Ref 10CFR73.21).Violation & Open Item Noted. Major Areas Inspected:Mgt Effectiveness,Security Organization,Records & Repts & Testing & Maint IR 05000266/19880061988-04-0505 April 1988 Insp Repts 50-266/88-06 & 50-301/88-06 on 880201-0315.No Violations or Deviations Noted.Major Areas Inspected:Action on Previous Insp Findings,Temporary Instructions,Operational Safety,Maint,Surveillance,Physical Security & LER Followup IR 05000266/19880071988-03-29029 March 1988 Insp Repts 50-266/88-07 & 50-301/88-07 on 880307-11.No Violations,Deficiencies or Deviations Noted.Major Areas Inspected:Emergency Preparedness Program,Including Action on Previous Open Items & Activations of Emergency Plan IR 05000266/19880051988-03-11011 March 1988 Insp Repts 50-266/88-05 & 50-301/88-05 on 880208-12.No Violations or Deviations Noted.Major Areas Inspected:Qa & Confirmatory Measurements for in Plant Radiochemical Analyses & Verification of TLD Collocation IR 05000266/19880031988-02-12012 February 1988 Insp Repts 50-266/88-03 & 50-301/88-03 on 880111-15.No Violations or Deviations Noted.Major Areas Inspected: Radiation Protection Program,Including Organization & Mgt Controls & Audits & Appraisals IR 05000266/19880021988-02-11011 February 1988 Insp Repts 50-266/88-02 & 50-301/88-02 on 871215-880131.No Violations or Deviations Noted.Major Areas Inspected:Maint, Previous Insp Findings,Operational Safety,Surveillance, Physical Security,Radiological Protection & LER Followup IR 05000266/19870231987-12-14014 December 1987 Insp Repts 50-266/87-23 & 50-301/87-21 on 871013-1124.No Violations or Deviations Noted.Major Areas Inspected: Inservice Insp Activities Including Review of Program, Procedures & Observation of Work IR 05000266/19870201987-11-16016 November 1987 Insp Repts 50-266/87-20 & 50-301/87-20 on 871001-31.No Violations or Deviations Noted.Major Areas Inspected:Maint, Operational Safety,Surveillance,Physical Security, Radiological Protection & Outages IR 05000266/19870211987-11-0909 November 1987 Insp Repts 50-266/87-21 & 50-301/87-22 on 871019-29.No Violations or Deviations Noted.Major Areas Inspected: Licensee Implementation of Generic Ltr 83-28 in Areas of Equipment Classification & Reactor Trip Sys Reliability IR 05000266/19870191987-10-28028 October 1987 Insp Repts 50-266/87-19 & 50-301/87-19 on 870921-1013.No Violations or Deviations Noted.Major Areas Inspected: Radiation Protection & Radwaste Programs,Including Organization & Mgt Controls & Audits & Appraisals IR 05000266/19870181987-10-14014 October 1987 Insp Repts 50-266/87-18 & 50-301/87-18 on 870914-17.No Noncompliance,Deficiencies or Deviations Noted.Major Areas Inspected:Plant Emergency Preparedness Exercise.Three Exercise Weaknesses Identified IR 05000266/19870171987-10-0909 October 1987 Insp Repts 50-266/87-17 & 50-301/87-17 on 870901-30.No Violations or Deviations Noted.Major Areas Inspected:Generic Ltr Followup,Maint,Surveillance,Physical Security, Operational Safety,Enforcement Conference & LER Followup IR 05000266/19870161987-10-0707 October 1987 Partially Withheld Security Insp Repts 50-266/87-16 & 50-301/87-15 on 870831-0904 (Ref 10CFR73.21).No Noncompliance Noted.Major Areas Inspected:Mgt Effectiveness, Security Plan/Implementing Procedures,Records,Repts & Maint IR 05000266/19870151987-09-17017 September 1987 Insp Repts 50-266/87-15 & 50-301/87-14 on 870716-0831.No Violations or Deviations Noted.Major Areas Inspected: Operational Safety,Maint,Surveillance,Physical Security, Radiological Protection & LER Followup ML20235E6941987-09-16016 September 1987 Insp Rept 50-301/87-16 on 870819-28.Violation Noted.Major Areas Inspected:Licensee Failure to Meet Tech Specs Re Operability of MSIVs & Licensee Failure to Rept Incident to NRC 1990-09-24
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARIR 05000266/19990151999-09-30030 September 1999 Insp Repts 50-266/99-15 & 50-301/99-15 on 990830-0903.No Violations Noted.Major Areas Inspected:Operations & Training IR 05000266/19990131999-09-29029 September 1999 Insp Repts 50-266/99-13 & 50-301/99-13 on 990714-0830.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000266/19993011999-09-0808 September 1999 NRC Operator Licensing Exam Repts 50-266/99-301OL & 50-301/99-301OL (Including Graded Tests) for Tests Administered on 990726-0802 IR 05000266/19990141999-08-31031 August 1999 Insp Repts 50-266/99-14 & 50-301/99-14 on 990726-30.No Violations Noted.Major Areas Inspected:Access Authorization Program,Alarm Stations & Communications.Security Mgt Also Inspected IR 05000266/19990091999-07-28028 July 1999 Insp Repts 50-266/99-09 & 50-301/99-09 on 990528-0713. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support IR 05000266/19990121999-07-14014 July 1999 Insp Repts 50-266/99-12 & 50-301/99-12 on 990614-18.No Violations Noted.Major Areas Inspected:Implementation of Inservice Test Program & MOVs Capability,Per GL 96-05 IR 05000266/19990081999-06-18018 June 1999 Insp Repts 50-266/99-08 & 50-301/99-08 on 990411-0527.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support PNO-III-99-027, on 990514,Unit 1 Was Manually Tripped Due to Steam Leak from 4B Feedwater Heater.Nrc Resident Inspectors Monitored Activities in CR Following Reactor Trip & Monitoring Progress of Repair Work.Licensee Notified NRC1999-05-19019 May 1999 PNO-III-99-027:on 990514,Unit 1 Was Manually Tripped Due to Steam Leak from 4B Feedwater Heater.Nrc Resident Inspectors Monitored Activities in CR Following Reactor Trip & Monitoring Progress of Repair Work.Licensee Notified NRC IR 05000266/19990061999-05-0707 May 1999 Insp Repts 50-266/99-06 & 50-301/99-06 on 990223-0410. Non-cited Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support ML20206E3331999-04-28028 April 1999 Notice of Violation from Insp on 990105-022.Violation Noted: Between 981222 & 990105,low Temp Condition with Potential to Cause Freezing of Common Min Flow Line Was Not Identified Nor Cause Determined IR 05000266/19990051999-04-20020 April 1999 Insp Repts 50-266/99-05 & 50-301/99-05 on 990222-0312. Violations Noted.Major Areas Inspected:Effectiveness & Engineering & Technical Support Organization in Performance of Routine & Reactive Site Activities & Problem Prevention IR 05000266/19990101999-04-19019 April 1999 Insp Repts 50-266/99-10 & 50-301/99-10 on 990329-0401.No Violations Noted.Major Areas Inspected:Review of Emergency Preparedness Program & Aspect of Plant Support IR 05000266/19990071999-03-16016 March 1999 Insp Repts 50-266/99-07 & 50-301/99-07 on 990216-19.No Violations Noted.Major Areas Inspected:Routine Insp of Radiation Protection & Chemistry Program Which Included Water Chemistry Control Program ML20204D8311999-03-12012 March 1999 Insp Rept 50-266/99-04 on 990105-0222.One Violations of NRC Requirements Occurred & Being Treated as non-cited Violation.Major Areas Inspected:Operations,Maint & Engineering ML20207L1211999-03-10010 March 1999 Notice of Violation from Insp on 990105-0222.Violation Noted:As of 990129,Operations Manual 3.7, AOP & EOP Sets Use & Adherence, Rev 5,major Procedure Prescribing Activities Affecting Quality,Inappropriate for Circumstance IR 05000266/19990021999-03-10010 March 1999 Insp Repts 50-266/99-02 & 50-301/99-02 on 990105-0222. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support IR 05000266/19990031999-02-0101 February 1999 Insp Repts 50-266/99-03 & 50-301/99-03 on 990111-15.No Violations Noted.Major Areas Inspected:Review of Plant Support Activities Relating to Physical Protection of Facility ML20199H5621999-01-15015 January 1999 Notice of Violation from Insp on 981121-990104.Violations Noted:As of 981015,adequate VT-2 Visual Exam of Pressure Retaining Boundary of Sfsp Common to Units 1 & 2 Not Performed During Each Code Insp Period IR 05000266/19980211999-01-15015 January 1999 Insp Repts 50-266/98-21 & 50-301/98-21 on 981121-990104. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000266/19980221998-12-24024 December 1998 Insp Repts 50-266/98-22 & 50-301/98-22 on 981208-10.No Violations Noted.Major Areas Inspected:Maint Rule Program IR 05000206/19980191998-12-0404 December 1998 Insp Repts 50-206/98-19 & 50-301/98-19 on 981004.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000266/19980201998-11-30030 November 1998 Insp Rept 50-266/98-20 & 50-301/98-20 on 981102-06.No Violations Noted.Major Areas Inspected:Plant Biennial Exercise of Emergency Plan IR 05000266/19980171998-10-26026 October 1998 Insp Repts 50-266/98-17 & 50-301/98-17 on 980818-1005.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000266/19980181998-10-0202 October 1998 Insp Repts 50-266/98-18 & 50-301/98-18 on 980831-0904.No Violations Noted.Major Areas Inspected:Radiation Protection Program,Including Review of Whole Body Counter Calibration, Portable Instrument Calibration & Routine Contamination IR 05000266/19980131998-09-11011 September 1998 Insp Repts 50-266/98-13 & 50-301/98-13 on 980608-12 & 0715-16.Violations Noted.Major Areas Inspected:Adequacy of Licensee Programs,Procedures,Training,Equipment & Supporting Documentation for Maint of Medium Voltage & Low Voltage ML20151Y2571998-09-11011 September 1998 Notice of Violations from Insp on 980608-12 & 0715-16. Violations Noted:Licensee Failed to Determine Lowest Voltages Available at Breaker Close & Trip Coils Since Original Installation of Breaker IR 05000266/19980151998-09-11011 September 1998 Insp Repts 50-266/98-15 & 50-301/98-15 on 980720-31.No Violations Noted.Major Areas Inspected:Adequacy of Licensee Programs,Procedures,Training & Supporting Documentation to Ensure TS Required Surveillance Testing IR 05000266/19980141998-09-0303 September 1998 Insp Repts 50-266/98-14 & 50-301/98-14 on 980707-0817.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000266/19980161998-08-10010 August 1998 Insp Repts 50-266/98-16 & 50-301/98-16 on 980713-17.No Violations Noted.Major Areas Inspected:Review of Plant Support Activities Re Physical Protection of Facility IR 05000266/19983011998-07-29029 July 1998 NRC Operator Licensing Exam Repts 50-266/98-301 & 50-301/98-301 (Including Completed & Graded Tests) for Tests Administered on 980622-25.One SRO License Applicant Passed All Portions of Exam & Issued Operating License ML20236V6621998-07-29029 July 1998 Insp Repts 50-266/98-11 & 50-301/98-11 on 980526-0706. No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20249C2851998-06-19019 June 1998 Notice of Violation from Insp on 980414-0523.Violation Noted:Licensee Did Not Test Some Refueling Sys Interlocks During Refueling Shutdowns from Time of Initial Plant Refueling Through 980422 IR 05000266/19980091998-06-19019 June 1998 Insp Repts 50-266/98-09 & 50-301/98-09 on 980414-0523. Violation Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000266/19980121998-06-11011 June 1998 Insp Repts 50-266/98-12 & 50-301/98-12 on 980518-22. Violations Noted.Major Areas Inspected:Review of Unit 1 Refueling Outage Doses,Solid Radwaste Mgt,Transportation of Radioactive Matls & Health Physics Program ML20249A0621998-06-11011 June 1998 Notice of Violation from Insp on 980518-22.Violation Noted: Two Emergency Plan SRDs Available for Use in Emergency Plan Sampling Kits,Not Calibrated in Dec 1997 IR 05000266/19980071998-06-0303 June 1998 Insp Rept 50-266/98-07 on 980310-13,16,17,0401-02,22,24 & 0504-05.No Violations Noted.Major Areas Inspected: Maint & Engineeing ML20247D6681998-05-0505 May 1998 Notice of Violation from Insp on 971216-980309.Violations Noted:Weld Procedure Wps GT-SM/1.1-1 Pb,Rev 4,used to Fabricate SG Replacement Main Steam & Feedwater Welds,Did Not Meet Requirements of QW-409.1 IR 05000301/19980051998-05-0505 May 1998 Insp Rept 50-301/98-05 on 971216-980309.Violations Noted. Major Areas Inspected:Maint ML20247D2961998-05-0505 May 1998 Insp Repts 50-266/98-06 & 50-301/98-06 on 980303-0413. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000266/19980081998-04-15015 April 1998 Insp Repts 50-266/98-08 & 50-301/98-08 on 980316-20.No Violations Noted.Major Areas Inspected:Radiation Protection Performance During Refueling Outage ML20217J4521998-04-0101 April 1998 Notice of Violation from Insp on 980310-18.Violation Noted: as of 980313,licensee Failed to Establish Measures to Assure That Conditions Adverse to Quality,Promptly Identified & Corrected ML20217J4571998-04-0101 April 1998 Insp Repts 50-266/98-10 & 50-301/98-10 on 980310-18. Violations Noted.Major Areas Inspected:Review of Measuring & Test Equipment Procedures ML20217D3451998-03-21021 March 1998 Notice of Violation from Insp on 980120-0302.Violation Noted:Replacement of 10CFR50,App B,Criterion V,State,In Part,That Activities Affecting Quality Shall Be Prescribed by Documented Instructions ML20217D3531998-03-21021 March 1998 Insp Repts 50-266/98-03 & 50-301/98-03 on 980120-0302. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support PNO-III-98-023, on 980305,unit 2 Completed TS-required Shutdown After Declaring CCW Sys Inoperable.While Shutdown, Licensee Plans to Conduct More Detailed Analysis of Postulated Failure1998-03-0606 March 1998 PNO-III-98-023:on 980305,unit 2 Completed TS-required Shutdown After Declaring CCW Sys Inoperable.While Shutdown, Licensee Plans to Conduct More Detailed Analysis of Postulated Failure IR 05000266/19980041998-02-27027 February 1998 Insp Repts 50-266/98-04 & 50-301/98-04 on 980202-06.No Violations Noted.Major Areas Inspected:Review of Health Physics Dept Preparations for Unit 1 Refueling Outage, Including ALARA Planning & Work Planning ML20203D4361998-02-19019 February 1998 Insp Repts 50-266/97-23 & 50-301/97-23 on 971020-1107. Violations Noted.Major Areas Inspected:Licensee Controls in Area of SEs as Well as Effectiveness of Licensee Controls in Identifying,Resolving & Correcting Problems IR 07100020/20110071998-02-19019 February 1998 Notice of Violation from Insp on 971020-1107.Violation Noted:Danger Tags 97-753 & 97-800 Were Installed on 971007 & 18,w/o Tag Sequence Numbers Being Assigned to Danger Tag Location Sheet IR 05000266/19970221998-02-18018 February 1998 Insp Repts 50-266/97-22 & 50-301/97-22 on 971104-980203.No Violations Noted.Major Areas Inspected:Review of 20 Licensee Event Repts Submitted Between 960909 & 971215 ML20202E9641998-02-10010 February 1998 NOV from Insp on 971201-980120.Violation Noted:From 980108- 09,operators Failed to Initiate Actions within 1 H to Place Unit in Hot Shutdown When Both Unit 1 safety-related 4,160- Volt Buses Were Powered from Standby Emergency Power Supply 1999-09-08
[Table view] |
Text
,
,
.
.
U.S. NUCLEAR REGULATORY COMMISSION
REGION III
Reports No. 50-266/83-08(DRMSP); 50-301/83-08(DRMSP)
Docket Nos. 50-266; 50-301 Licenses No. DPR-24; UPR-27 Licensee: Wisconsin Electric Power Company 231 West Michigan Milwaukee, WI 53201 Facility Name: Point Beach Nuclear Power Plant, Units I and 2 Inspection At: Point Beach Site, Two Creeks, WI and WEPC0 Corporate Office, Milwaukee, WI
'
Inspection Conducted: May 9-11 and June 9, 1983 Inspector:
0 S. MNff P. C. Lovendale 6 /30/8'3 Date Approved By:
xA!.77ulL/P L. R. Greger, Chief 6 /-T e / r 3 Facilities Radiation Protection D(te Section Inspection Summary Inspection on May 9-11 and June 9,1983, (Reports No. 50-266/83-08(DRMSP);
50-301/83-08(DRMSP))
Areas Inspected: Special, unannounced inspection of radiation protection activities during the Unit 2 steam generator sleeving outage, and prepara-tions for the Unit 1 steam generator replacement outage. Also, certain licensee events and TMI Action Plan Items were reviewed. The inspection
. involved 26 inspector-hours onsite by one NRC inspecto Results: Of the six areas inspected, no items of noncompliance were identified in four areas; one item of noncompliance was identified in each of two areas (failure to collect air samples - Section 7, and failure to comply with an NRC Order - Section 9).
!
I 8307180047 830701 PDR ADOCK 05000266 O PDR
,_ -. _____ ___-___ _ _ _ _
.
.
DETAILS 1. Persons Contacted
- R. Bredvad, Plant Health Physicist
- F. Flentje, Supervisor, Staff Services C. Krause, Licensing Engineer, WEPC0 D. LeQuia, Radiation Safety Supervisor R. Newton, Superintendent, Reactor Engineering, WEPC0
- J. Reisenbucchler, Superintendent, Technical Services
- P. Skramstad, Superintendent, Chemistry and Health Physics
- J. Zach, Manager, Point Beach Nuc1 car Plant
- B. Fitzpatrick, NRC Resident Inspector
- D. Hague, NRC Senior Resident Inspector
- Denotes those present at the exit meetin . General
/
This inspection, which began at 9:00 a.m. on May 9, 1983, was conducted to examine radiation protection activities during the Unit 2 steam generator sleeving outage and to review licensee preparations for the Unit I steam generator replacement project scheduled to begin in October 1983. Also, the status of certain TMI Action Plan Items and licensee actions taken in response to certain events were reviewe . Licensee Action on Previous Iiscpaction Findings (Closed) Open Item (266/79-04-01; 301/79-03-01)s Tritium in the subsoil drainage system. This matter was reviewed during a previous inspection (50-266/82-06; 50-301/82-06) and it was determin'ed that additional sampling was needed to help identify the source of small amounts of tritium that have been found in the subsoil drainage system. The licensee has conducted further sampling and has compiled and analyzed all data collected to date. The exact source of the tritium can still not be determined. The licensee continues to monitor and quantify these very small releases and reports the releases in their semi-annual effluent repor . Unit 2 Steam Generator Sleeving Activities The radiation protection aspects of the Unit 2 steam generator sleeving project were reviewed. At the time of this inspection, the licensee had completed decontamination of both steam generators and had installed about 80 percent of the sleeves in steam generator "B".
The licensee's health physics staff has been augmented with sixty-three contracted radiation protection technicians and five record clerks. Many of the contracted technicians have worked at Point Beach during previous outages. A selective review of technician qualifications and utilization was conducted; no problems were note ._ .. . . _ ._ _ _ _ - _ _
.
,
.
Total occupational exposure for the sleeving project to date is about i
360 person-rems which is only slightly higher than licensee pre-outage estimates. The slightly higher than planned exposures may be due to
,
the low steam generator decontamination factors (DFs) achieved. The DFs were 3.5 and 2.25 for steam generators "A" and "B", respectivel i Based on experimental data, the expected DF was 4 to The inspector toured the Unit 2 containment and observed the radiation
. protection activities associated with the steam generator sleeving project. The ace.ess control station for steam generator area entries was observed as teing well equipped, and functionally efficient. All
- steam generator activities could be clearly monitored remotely with numerous video cameras and monitors. A worker hold area has been established within a low level radiation area where workers remain while waiting to enter the work area. Air sampling, radiation / contamination surveys, and personal monitoring appeared
- adequate, i
j No items of noncompliance or deviations were identifie . Unit 1 Steam Generator Replacement Preparations
'
The licensee's health physics related advanced planning and prepara-tions for the Unit I steam generator replacement were reviewed. Most i facility construction appears to be progressing well. The steam I generator mausoleum is currently under construction and construction of the containment access building is scheduled to begin about June 1,
'
198 The licensee's proposed health physics organization for steam generator replacement was reviewed. The subcontractor (Morrison-Knudsen) has filled all key health physics positions within their proposed organiza-j tion. These individuals are primarily responsible for operational health
'
physics activities associated with the project. The prime contractor
] (Westinghouse) has been slow to fill several key health physics positions within their health physics organization. These positions include the
- Health Physics Director, the ALARA Coordinator, the In-vivo Count and
', Respirator Test Coordinator, and other key individuals primarily responsible for health physics support activities. This matter was discussed during the exit meeting.
i
,
6. Reactor Coolant Filter Venting Incident The inspector reviewed licensee actions taken in response to a personal
,
contamination incident which occurred while changing a reactor coolant filter on March 25, 1983. While filling the filter housing following filter replacement, the filter inlet valve became stuck so it could not
- be shut using the remote operator. Because he was concerned the vent i
hosc may disconnect under excessive pressure causing coolant to spray
- into the cubicle, a worker entered the cubicle and shut the reactor coolant filter vent valve. This action stopped the flow of coolant from the vent hose. This hose drained into a floor drain and then to i
'
,
radwaste. No respiratory protection was worn.
i
!
.
l
, _ = , - . - - _ _ _ _ _ .- ._- . _ _ _ - - , _ _ ---
. .. .. . . ... . . _ . __
.
+
The-coolant that flowed from the reactor coolant filter vent to the l t floor-drain degassed causing high airborne activity (primarily noble gas) within the cubicle. The licensee conservatively calculated the airborne radioactivity within the cubicle based on reactor coolant i activity. Based on this calculation and the worker's stay time, cal-culations of MPC-hrs, skin dose, and whole body dose were conducted, i These calculations indicate that the 40 MPC-hr control measure was not exceeded. The skin and whole body doses based on submersion in a semi-infinite cloud were calculated to be about 180 mrads and 90
,
mrems respectively. The inspector reviewed the calculations; no problems were noted.
>
Following the job, .the worker was found to be contaminated with noble j gas daughter products on his face, throat, and arms. The maximum level
'
of contamination was about 1000 dpm/cm on his face. The worker was successfully decontaminated and was whole body counted. The results show that no significant uptake occurred.
4 'As corrective actions, the licensee is revising the reactor coolant filter change procedure to preclude the possibility of entries into i
. the cubicle while venting the filter. A modification is being con-
, sidered which would direct gases from the venting operation to the ventilation system.
s Also, respirators will be worn during any entry into the cubicle.
Previously, respirators were only required while the filter housing was open. No problems were note No items of noncompliance or deviations were identified. . Elevated Iodine in Unit 2 Containment Air
'The inspector reviewed licensee actions taken in response to elevated iodine levels in the Unit 2 containment air immediately following reactor vessel head remova ! At about 1:00 p.m. on March 31, 1983, several workers. leaving contain-
'
ment were found to be slightly contaminated. Nasal swabs indicated possible airborne radioactivity. These workers had been working in the vicinity of the seal table and it was initially assumed that there ma be a radiological problem in that area. However, air samples collected
.near the' seal table did not indicate any significant airborne radio-
'
c.tivity. Whole body counts conducted the following day indicated small
. uptakes of I-131 by the workers.
'
Earlier in the-day on March 31, 1983, the reactor-vessel head was removed and the cavity flooded. These~ operations began at about 8:40 a.m.
and the' vessel head was placed in the laydown area at about 11:20 a.m.
. At'about noon, it was noted that' the low volume air sampler on the 66-
!. - foot : level (refueling floor) was unplugged. It is believed that the ,
'
sampler had been' unplugged since the last filter change at.7:00 a.m. on
March 31. -The air sampler was restarted, but the filter:and charcoal
. cartridge were not changed and counted until about 6:20 p.m., nearly ten
,
4 ,_ . . . . - , _ . - , _ . . . - ._ _ _ __ _
.
.
hours after the reactor vessel head lift and cavity flood operations began. In addition, an air sampler which draws a sample from inside the cavity did not have a charcoal cartridge installed. Therefore, no air-borne iodine determinations were made on the 66-foot level or in the cavity during the reactor head lift and start of the cavity fill operation. The results of the refueling floor air sample which ran from 12:00 p.m. to 6:20 p.m. Indicated I-131 concentrations of about one times MPC when averaged over the 6.5 hour5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> sample run tim Iodine levels remained at about one to two times MFC until about 10:00 p.m. on April 2, 1983. Failure to collect and evaluate air samples during reactor vessel head removal and cavity flood operations is considered noncompliance with 10 CFR 20.103(a)(3), which requires air sampling for purposes of deter-mining worker uptake of radioactive materia (301/83-08-01)
Based on whole body counts of workers in the vicinity of the seal table and the 66-foot level air sample results, workers involved with the head lift were whole body counted. The results of these vlale body counts indicated small I-131 uptakes (maximum was about 24 MPC-hrs) and led the licensee to the realization that the problem was likely caused by the head lift and cavity fill operations and not by any seal tabic area wor The licensee tracked MPC-hrs for all workers entering containment during this period. The inspector selectively reviewed these records; no problems were note On April 2, 1983, the licensee began spraying hydrazine over the cavity water which significantly reduced the amount of iodine coming out of solution. It was later Icarned from Westinghouse that the licensee may not have reduced coolant iodine levels to below recommended levels of IE-2 microcuries per milliliter prior to the reactor vessel head lift and cavity flood operation (Elevated coolant iodine levels had been experienced due to a damaged fuel assembly.) A Westinghouse representa-tive indicated that this information (recommended refueling iodine levels) was made available to all Westinghouse plants, however, the licensee stated that they were not made aware of this informatio This matter will be reviewed further during a future inspectio (266/83-08-01; 301/83-08-02)
This event was discussed during the exit meeting. Licensee corrective actions related to the licensee's air sampling program will be reviewed during a future inspectio . Elevated Containment Noble Gas Levels The inspector reviewed licensee actions taken in response to elevated Unit 2 containment noble gas levels during a reactor vessel refilling operation. During this operation, gas was vented into containment through the reactor vessel head vent and the instrument port conoscal openings. Normally, the gas would have been vented out through the containment purge and exhaust system, but the hose connecting the reactor vessel head vent with the containment purge and exhaust had been removed to facilitate reactor vessel stud detensioning (normal procedure). The maximum gaseous activity concentration was about 3E-4 microcuries per millilite .
.
It was not readily apparent whether the licensee's procedure for head venting was followed and was adequate. Also, it is not clear as to whether having the vent rig installed would have provided the needed negative piessure within the vessel head to prevent the gas from escaping through the conoscal openings. This matter is considered an unresolved item that will be reviewed further during a future inspectio (266/83-08-02; 301/83-08-03)
9. TMI Action Plan Items II.F.1.1 and II.F. The inspector reviewed the status of TMI Action Plan Items II.F.1.1,
" Noble Gas Effluent Monitor" and II.F.1.2, " Sampling and Analysis of Plant Effluents." On March 14, 1983, an NRC Confirmatory Order was issued which listed both of these items as complete based on licensee submittals dated April 26 and July 20, 1982, and verbal discussions with licensee representatives. Except for power supply problems, the submittals indicated that these items would be complete by December 198 As indicated in the licensee's July 20, 1982 submittal, the required vital bus power supply for these monitoring systems will not be avail-able until af ter a bus upgrade project has been completed (currently scheduled for December 1983).
To meet the requirements of Item II.F.1.2, the licensee has installed an isokinetic stack sampling system. Except for connection to the final power supply, installation of this system appears to be complet To meet the requirements of Item II.F.1.1, the licensee has installed an Eberline SPING-4 monitor on each containment vent, a SPING-4 monitor on the auxiliary building vent, and a SPING-3 monitor on the drumming area vent. Except for connection to the final power supply, installa-tion of these monitors appears to be complete. Monitoring of the main steam line pathway is also needed to complete Item II.F. Externally mounted SA-ll gamma monitors were to be installed on each main steam line. During a telephone conversation with a licensee representative on May 16, 1983, the inspector learned that the SA-11 main steam line monitors had not been calibrated and therefore were not operational, and further that these monitors had not been installed by the December 1982 commitment date or the March 14, 1983 Order dat Between the committed completion date of December 1982 and the Order dated March 14, 1983, the licensee apparently did not contact the NRC concerning delays in completion of the main steam line installatio It appears that between March 14, 1983, and the date of this inspection, the licensee had not thoroughly reviewed the status of these monitors for compliance to the Order. This is supported by statements made to the inspector by the WEPCO Licensing Engineer and the WEPC0 Reactor Engineering Superintendent during an interview at the corporate office on June 9, 1983, and during a telephone call on June 13, 1983. Both stated that only the July 20, 1982 letter was reviewed against the requirements set forth in the Order. Both stated that they believed that the July 20 letter to NRR contained the most up-to-date information concerning schedular commitments. However, only the April 26, 1982, letter discusses the SA-11 main steam line monitor installation _
l
-
l
i
)
Prior to issuance of the March -14,1983 Order, the NRR Licensing Project Manager telephoned the WEPCO Licensing Engineer concerning the status of certain TMI Action Plan Items. According to the two individuals, the NRR Licensing Project Manager asked if previously submitted completion dates had been met or if further extensions of those dates were needed. Based on the contents of the July 20, 1982, letter, the WEPC0 Licensing Engineer informed the NRR Project Manager that he thought the previously submitted completion dates had been or could be met. Based on this telephone conversation and the April 26, and July 20, 1982, licensee submittals (among others), a Confirmatory Order which listed item II.F.1.1 as complete was issued on March 14, 198 Upon receipt by the licensee, the Order was reviewed by the Licensing Engineer and the Reactor Engineering Superintendent. According to these two individuals, they did not consider their April 26, 1982, submittal while reviewing the Order contents; this omission resulted in their failure to recognize that the SA-11 main steam line monitors were not operational as required by the Order. A major contributor to this problem is the lack of an effective licensee tracking system for the THI Action Plan Items. This matter was discussed at the exit meetin The March 14, 1983, Confirmatory Order requires the licensee to implement and maintain those items listed as complete. The SA-11 main steam line monitors are needed to complete Item II.F.1.1. Failure to have the SA-11 main steam line monitors operational is considered noncompliance with the Orde (266/83-08-03; 301/83-08-04)
10. Unresolved Items Unresolved items are matters about which more information is required in order to ascertain whether they are acceptable items, items of non-compliance, or deviations. An unresolved item disclosed during the inspection is discussed in Section . Exit Meeting The inspector met with licensee representatives (denoted in Section 1)
at the conclusion of the inspection on May 11, and June 9, 1983. The inspector summarized the scope and findings of the inspection. Further discussions between the inspector and licensee management were conducted by telephone on May 16, 20, 23, and~ June 10, 1983. Also, a telephone discussion on May 20, 1983, between NRC Region III management and licensee corporate management, resulted in the issuance of a Confirmatory Action Letter, dated May 20,'1983. (266/83-08-04; 301/83-08-05)
.
In response to certain items discussed, the licensee: Stated that Westinghouse would be asked to provide a schedule for the filling of certain key health physics positions. The inspector expressed concern that further delays in filling these key positions may result-in inadequate project preparation. (Section 5)
_ _ _ _ _ . _ . .__ _
.
.
. Stated _that a continuous air monitor will be purchased for the refueling floor and that steps would be taken to further improve the air sampling progra (Section 7) Stated that the SA-Il main steam line monitors would be installed, operating, and' calibrated by June 30, 1983. This date was documented in the May 20, 1983 Confirmatory Action Lette (Section 9) Stated that NRR would be reminded of the fact that monitors installed to satisfy TMI Action Plan Items II.F.I.1 and II.F. will be powered from an interim power supply until completion of the bus upgrade. A date for completion will be provide Acknowledged the items of noncomplianc (Sections 7 and 9)
I s
i u
l
i