1 4

September 7, 1993 Docket Nos. 50-352 Mr. George A. Hunger, Jr.

Manager-Licensing, MC 52A-5 Philadelphia Electric Company Nuclear Group Headquarters Correspondence Control Desk P.O. Box No. 195 Wayne, Pennsylvania 19087-0195

Dear Mr. Hunger:

SUBJECT:

SAFETY EVALUATION FOR PERFORMING BOLT REMOVAL REQUIREMENTS, RELIEF l REQUEST 20, LIMERICK GENERATING STATION, UNIT 1 (TAC NO. M86312)  !

By letter dated April 19, 1993, you requested relief from American Society of  !

Mechanical Engineers (ASME) Code,Section XI, Class 2 requirements to remove l all of the bolting from a flanged joint for visual examination because the flanged joint leaked during a hydrostatic test. The code of record is the 1986 Edition of the ASME Code. The 1989 Edition of the ASME Code requires that only one bolt must be removed and visually enmined from a flanged joint that leaks during a hydrostatic test. Based on the discussion provided in your submittal, the staff approves the use of a portion of the 1989 Edition of j ASME Code, IWA-5250(a)(2) until the end of the current fuel cycle, according 1 to the provisions of the Title 10 of the Code of Federal Regulations (CFR) l 50.55(a)(g)(4)(iv).

The staff's Safety Evaluation is enclosed.

The staff considers this matter resolved and is closing out TAC No. M86312.

If you have any questions, please call Frank Rinaldi at (301) 504-1447.

Sincerely,

/S/

Michael L. Boyle, Acting Director l Project Directorate I-2 Division of Reactor Projects - I/II i Office of Nuclear Reactor Regulation j

Enclosure:

Safety Evaluation cc w/ enclosure:  !

See next page i DISTRIBUTION

' [~ ~ Docket File SVarga GHill(2) JStrosnider I NRC & Local PDRs JCalvo ACRS(10) JDavis

,Mo b PDI-2 Reading TMurley/FMiraglia MBoyle FRinaldi OPA OC/LFDCB l 00' JPartlow M0'Brien VMcCree, 17G-21

! @@ ERossi OGC EWenzinger, RGN-I do JLieberman EJordan, 3701 CAnderson, RGN-I ru *See previous concurrence eu m t 00 b 0FFICE PDIh7k PDI-2/EMur *EMCB OGC PDI-2/D a

$ NAME M0' hr[i[n' FRi[uIdf.hb- JStrosnider A/7/<3pt MBoyle @ r i

n. DATE [/h93 f/[/93 08/14/93 f/,7_/93 $/I/93 p L i 0FFICIAL RECORD COPY DOCUMENT NAME: i.186312. GEN Q (( %[h hh

?

pn nc%  ;

'. fY #+

UNITED STATES

[.j

[) .

t NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 205564X101

  • {.g

%, N...../ September 7, 1993 Docket Nos. 50-352 Mr. George A. Hunger, Jr.

Manager-Licensing, MC 52A-5 Philadelphia Electric Company Nuclear Group Headquarters Correspondence Control Desk P.O. Box No. 195 Wayne, Pennsylvania 19087-0195

Dear Mr. Hunger:

I

SUBJECT:

SAFETY EVALUATION FOR PERFORMING BOLT REMOVAL REQUIREMENTS, RELIEF REQUEST 20, LIMERICK GENERATING STATION, UNIT 1 (TAC NO. M86312)

By letter dated April 19, 1993, you requested relief from American Society of Mechanical Engineers (ASME) Code,Section XI, Class 2 requirements to remove all of the bolting from a flanged joint for visual examination because the flanged joint leaked during a hydrostatic test. The code of record is the 1986 Edition of the ASME Code. The 1989 Edition of the ASME Code requires that only one bolt must be removed and visually examined from a flanged joint that leaks during a hydrostatic test. Based on the discussion provided in your submittal, the staff approves the use of a portion of the 1989 Edition of ASME Code, IWA-5250(a)(2) until the end of the current fuel cycle, according i

to the provisions of the Title 10 of the Code of Federal Regulations (CFR) '

50.55(a)(g)(4)(iv).

The staff's Safety Evaluation is enclosed. I t

The staff considers this matter resolved and is closing out TAC No. M86312.

If you have any questions, please call Frank Rinaldi at (301) 504-1447. t Sincerely,  !

4 0

l . Michael L. Bo e, Acting Director l Project Directorate I-2 l

Division of Reactor Projects _- I/II Office of Nuclear Reactor Regulation l

l

Enclosure:

i Safety Evaluation cc w/ enclosure:

See next page

1 .

l .

( Mr. George A. Hunger, Jr. Limerick Generating Station, I i Philadelphia Electric Company Units 1 & 2  ;

I I

cc:  ;,

J. W. Durham, Sr., Esquire Mr. William P. Dornsife, Director i Sr. V.P. & General Counsel Bureau of Radiation Protection  ;

Philadelphia Electric Company PA Dept. of Environmental Resources 2301 Market Street P. O. Box 8469 .

Philadelphia, Pennsylvania 19101-Harrisburg, Pennsylvania 17105-8469 '

Mr. Rod Krich 52A-5 Mr. James A. Muntz  ;

Philadelphia Electric Company Superintendent-Technical t 955 Chesterbrook Boulevard Limerick Generating Station '

Wayne, Pennsylvania 19087-5691 P. O. Box A Sanatoga, Pennsylvania 19464  ;

Mr. David R. Helwig, Vice President Limerick Generating Station Mr. James L. Kantner i Post Office Box A Regulatory Engineer ,

Sanatoga, Pennsylvania 19464 Limerick Generating Station P. O. Box A Mr. Robert Boyce Sanatoga, "ennsylvania 19464 l Plant Manager  ;

Limerick Generating Station Library ,

P.O. Box A US Nuclear Regulatory Commission i Sanatoga, Pennsylvania 19464 Region I i 475 Allendale Road  ;

Regional Administrator King of Prussia, PA 19406 i U.S. Nuclear Regulatory Commission l Region I Mr. Larry Hopkins  !

475 Allendale Road Superintendent-0perations King of Prussia, PA 19406 Limerick Generating Station P. O. Box A '

Mr. Neil S. Perry Sanatoga, Pennsylvania 19464  !

Senior Resident Inspector  :

US Nuclear Regulatory Commi::sion Mr. John Doering, Chairman j P. O. Box 596 Nuclear Review Board Pottstown, Pennsylvania 19464 Philadelphia Electric Company 955 Chesterbrook Boulevard Mr. Craig L. Adams Mail Code 52C-1 Superintendent - Services Wayne, Pennsylvania 19087 Limerick Generating Station P.O. Box A Sanatoga, Pennsylvania 19464 i

. l

. - * + - w v w w - w w+